Attachment__2__140818_-_DRAWINGS_-_USDA_GF_Partial_Exterior_Facade_Renovation20140819.pdf
PDF 12 MB Posted
- Solicitation number
- AG-32SD-S-15-0014
About this file
Drawings
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2nd Ave N
N C o lu m b ia
R d
University Ave
N th
S t
USDA Human Nutrition Research
Center
A B C D F G H
IE
WEST
WING
EAST
WING
PROJECT AREAS
J L
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:0
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
COVER SHEET
Project Number
DSS
VGD
08/18/14
VGD
GRAND FORKS HUMAN NUTRITION RESEARCH
LABORATORY PARTIAL EXTERIOR FACADE RENOVATION
1 35
000-GENERAL
001 COVER SHEET
A0.10 GENERAL NOTES & SYMBOLS
A0.11 ABBREVIATIONS
100-DEMO
A1.0.01 DEMO - PHASE 1
A1.0.02 DEMO - PHASE 2
A1.0.03 DEMO - PHASE 3
A1.0.04 DEMO - PHASE 4
A1.0.05 DEMO - PHASE 5
200-PLANS
A2.0.00 OVERALL - PHASING
A2.1.01 PROPOSED PLAN - PHASE 1 - LEVEL 1
A2.1.02 PROPOSED PLAN - PHASE 1 - LEVEL 2
A2.1.03 PROPOSED PLAN - PHASE 1 - LEVEL 3
A2.1.04 PROPOSED PLAN - PHASE 1 - ROOF
A2.2.01 PROPOSED PLAN - PHASE 2 - LEVEL 1
A2.2.02 PROPOSED PLAN - PHASE 2 - LEVEL 2
A2.2.03 PROPOSED PLAN - PHASE 2 - LEVEL 3
A2.3.02 PROPOSED PLAN - PHASE 3 - LEVEL 2
A2.3.03 PROPOSED PLAN - PHASE 3 - LEVEL 3
A2.4.01 PROPOSED PLAN - PHASE 4 - LEVEL 1
A2.4.02 PROPOSED PLAN - PHASE 4 - LEVEL 2
A2.4.03 PROPOSED PLAN - PHASE 4 - LEVEL 3
A2.4.04 PROPOSED PLAN - PHASE 4 - LEVEL 4
A2.5.01 PROPOSED PLAN - PHASE 5 - PLAN, SECTION,
ELEVATION
300-ELEVATIONS & SECTIONS
A3.0.00 OVERALL - DEMO - WALL SECTIONS
A3.1.00 PROPOSED - PHASE 1 - ELEVATIONS
A3.1.01 PROPOSED - PHASE 1 - ELEVATIONS
A3.1.02 PROPOSED - PHASE 1 - WALL SECTIONS
A3.2.00 PROPOSED - PHASE 2 - ELEVATIONS
A3.2.02 PROPOSED - PHASE 2 - WALL SECTIONS
A3.3.00 PROPOSED - PHASE 3 - ELEVATIONS
A3.3.02 PROPOSED - PHASE 3 - WALL SECTIONS
A3.4.00 PROPOSED - PHASE 4 - ELEVATIONS
A3.4.02 PROPOSED - PHASE 4 - WALL SECTIONS
800-DETAILS
A8.0.00 DETAILS
A8.0.01 DETAILS
DRAWING INDEX
VICINITY MAP BUILDING REFERENCE PLAN CONTACTS
U.S. DEPARTMENT OF AGRICULTURE
AGRICULTURAL RESEARCH SERVICE
ARCHITECT
IRON HORSE ARCHITECTS
475 17TH STREET, SUITE 720
DENVER, CO 80202
PHONE: 720-763-8068
DATE
08/18/2014
DRAWING ISSUE
ISSUE
CONSTRUCTION DOCUMENTS
CLIENT
USDA CONTRACTING OFFICE 2150 CENTRE AVENUE
BUILDING D, SUITE 310
FORT COLLINS, CO 80526
GREG GRAHAM
PHONE: 970-492-7035
08/18/14 CONSTRUCTION DOCUMENTS
EXTERIOR ENCLOSURE SPECIALIST
MERRICK & COMPANY
5750 GREENWOOD VILLAGE, CO 80111
BOB HUSTON
PHONE: 303-751-0741
REV DATE
CONSTRUCTION SYMBOLS
A6.05
A6.05
A6.05
A101
Ref
A6.05
A101
1 1
A101
Ref
E7.4
BUILDING SECTION
DETAIL NUMBER, TYP
SHEET NUMBER, TYP
WALL SECTION
DETAIL NUMBER
SHEET NUMBER
DETAIL VIEW
DETAIL NUMBER
SHEET NUMBER
ENLARGED PLAN OR CALLOUT
DETAIL NUMBER
SHEET NUMBER
INTERIOR ELEVATION
DETAIL NUMBER, TYP
SHEET NUMBER
EXTERIOR ELEVATION
DETAIL NUMBER
SHEET NUMBER
COLUMN GRID
LEVEL 1
100' - 0"
ELEVATION MARKERS
FINISH FLOOR ELEVATION
LEVEL NAME
112' - 3"
SPOT ELEVATION
ELEVATION
ROOM NAME
1i
1t
99 99 99
ROOM NAME
ROOM NUMBER
ROOM TAG
DOOR TAG
WALL TAG
WINDOW TAG
SHEET KEYNOTE
REFERENCE KEYNOTE
2' 4'0' 16'8'8'
DRAWING NUMBER
SHEET NUMBER
GRAPHIC SCALE
NORTH ARROW
SHEET SYMBOLS
FINISH SYMBOLS
? FLOOR FINISH
? WALL FINISH
? WALL BASE FINISH
? SPECIAL FINISH
REVISION TAG1
STANDARD MATERIALS
ALUMINUM
BRICK
CONCRETE
CONCRETE MASONRY
EARTH
GLASS
GRAVEL
GYPSUM BOARD
INSULATION (BATT)
INSULATION (RIGID)
INSULATION (SPRAY)
PLASTER
PRE-CAST CONCRETE
SAND OR GROUT
STONE
FIRESAFING
STEEL
WOOD (FINISHED)
WOOD (CONTINUOUS MEMBER)
VIEW SCALE
VIEW NAME1
A101
GENERAL NOTES
1. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SHALL ESTABLISH LOCATION
OF ALL PARTITIONS, OPENINGS, EQUIPMENT, ETC.
2. LARGER SCALE DRAWINGS AND DETAILS HAVE PRIORITY OVER SMALLER SCALE
DRAWINGS.
3. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR
CONFLICTS IN THE DRAWINGS AND/OR SPECIFICATIONS, REQUEST AND RECEIVE
AN INTERPRETATION OR CLARIFICATION BEFORE PROCEEDING WITH
CONSTRUCTION.
4. CONTRACTOR SHALL VERIFY FIELD CONDITIONS BEFORE PROCEEDING WITH
CONSTRUCTION.
5. COORDINATE PHASED DEMOLITION WITH PHASED NEW WORK AS IDENTIFIED ON
THE DRAWINGS.
DEMOLITION NOTES
1. REMOVE AND PRESERVE DESIGNATED DOORS AND FRAMES, DUCTWORK, ELECTRICAL DEVICES, CONDUIT, WIRING DEVICES, LIGHTING FIXTURES, COMPONENTS, BUILDING EQUIPMENT, AND
FIXTURES FOR REINSTALLATION AS REQUIRED FOR NEW WORK. EXISTING FACILITY TO REMAIN
FULLY OPERATIONAL DURING CONSTRUCTION; COORDINATE ANY REMOVAL AND RE-
INSTALLATION OF BUILDING COMPONENTS WITH LOCATION FACILITY MANAGER.
2. REMOVE ABANDONED DUCTWORK, ELECTRICAL DEVICES AND CONDUIT, WIRING DEVICES, LIGHT
FIXTURES FROM ALL AREAS, EXCEPT WHERE OTHERWISE INDICATED ON THE DRAWINGS.
COORDINATE REMOVAL OF ANY ABANDONED ITEMS WITH LOCATION FACILITY MANAGER.
3. EXISTING FACILITY TO REMAIN FULLY OPERATIONAL DURING CONSTRUCTION. PROVIDE
TEMPORARY PARTITIONS, BARRICADES, GUARDRAILS, AND LIGHTING TO SECURE WORK AREAS;
CONTAIN DUST, SMOKE, FUMES, ETC. AND TO PROTECT AND ALLOW CONTINUED BUILDING
OCCUPANCY BY OWNER, TENANT, OTHER TENANTS, AND WORKERS. UPON COMPLETION,
REMOVE TEMPORARY PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT
SURFACES.
4. THE ARCHITECT SHALL NOT BE HELD LIABLE FOR ANY HAZARDOUS MATERIALS ON THE JOBSITE.
IF ASBESTOS, OR OTHER HAZARDOUS MATERIALS ARE DISCOVERED DURING CONSTRUCTION,
THE CONTRACTOR SHALL ISOLATE THE AFFECTED AREA AND CONTACT THE OWNER FOR
FURTHER INSTRUCTIONS BEFORE PROCEEDING.
5. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ALL UTILITIES DETERMINED IN
COURSE OF CONSTRUCTION AS BEING NECESSARY TO BE REMOVED WHICH HAVE NOT
OTHERWISE BEEN NOTED FOR REMOVAL IN THE CONSTRUCTION DOCUMENTS. CONTRACTOR
SHALL REMOVE SUCH UTILITIES ONLY AFTER CONSULTATION WITH THE ARCHITECT AND OWNER.
WHETHER PREDETERMINED IN THE CONSTRUCTION DOCUMENTS, OR DETERMINED LATER IN THE
FIELD, DISCONNECT, CUT BACK TO SOURCE, AND CAP ALL UTILITY SERVICES REMOVED. SEAL ALL
PENETRATIONS CREATED BY REMOVAL OF UTILITIES TO MATCH ADJACENT CONSTRUCTION AND
FINISHES.
6. COMPLY WITH APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS PERTAINING
TO SAFETY OF PERSONS, PROPERTY, AND ENVIRONMENTAL PROTECTION.
7. DO NOT INTERFERE WITH USE OF ADJACENT BUILDINGS; MAINTAIN FREE AND SAFE PASSAGE TO
AND FROM. EXISTING FACILITY TO REMAIN FULLY OPERATIONAL DURING CONSTRUCTION.
8. REPAIR ALL DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED, AT NO COST TO THE
CLIENT OR OWNER.
9. REMOVE TOOLS AND EQUIPMENT FROM SITE UPON COMPLETION OF WORK. LEAVE CONTRACT
AREAS AND SITE CLEAN, ORDERLY, AND IN A CONDITION ACCEPTABLE FOR NEW OR OTHER
CONSTRUCTION.
10. THE INTENT OF THE CONTRACT DOCUMENTS DEMOLITION IS TO REMOVE ALL NONSTRUCTURAL
ITEMS FROM THE INDICATED FACADES DOWN TO THE METAL STRUCTURAL FRAMING, UNLESS
OTHERWISE NOTED.
11. DEMOLITION, AS SHOWN ON THE DRAWINGS, SHALL BE REVIEWED ON SITE WITH THE CLIENT'S
PROJECT MANAGER REPRESENTATIVE PRIOR TO THE COMMENCEMENT OF THE WORK IN
ACCORDANCE WITH SPECIFICATIONS.
12. PROTECT ALL ITEMS AND FINISHES THAT ARE TO REMAIN OR BE RE-USED IN ACCORDANCE WITH
A PROTECTION PLAN TO BE REVIEWED AND APPROVED BY AN ARCHITECT. PATCH, REPAIR,
AND/OR REFINISH ANY AREAS TO REMAIN THAT ARE AFFECTED BY DEMOLITION SO THAT THEY
ARE CONTINUOUS, SMOOTH, AND MATCH ADJACENT FINISH.
13. REMOVE AND REATTACH FIXTURES ATTACHED TO WALL AS REQUIRED FOR DEMOLITION AND
NEW WORK, INCLUDING BUT NOT LIMITED TO COMPONENTS, BUILDING EQUIPMENT, DUCTWORK,
ELECTRICAL DEVICES AND CONDUIT, DOOR OPENERS, LIGHTS, ALARMS, AND SIGNS.
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:1
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
GENERAL NOTES & SYMBOLS
Project Number
DSS
VGD
08/18/14
VGD
A0.10 2 35
08/18/14 CONSTRUCTION DOCUMENTS
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:1
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
ABBREVIATIONS
Project Number
DSS
VGD
08/18/14
VGD
A0.11 3 35
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPD&S TOILET PAPER DISPENSER & SHELF
TPH TOILET PAPER HOLDER
TPTN TOILET PARTITION
TR TREADS
TRK TRACK
TS TUBE STEEL, TRANSITION (FLOORING)
TSTAT THERMOSTAT
TV TELEVISION
TWC TEXTILE WALL COVERING
TYP TYPICAL
U
UC UNDER COUNTER
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS LABORATORY, INC.
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V
V VOLT, VACUUM (OUTLET)
VAP VAPOR
VAR VARIABLE, VARNISH, VARIES
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VEH VEHICLE
VENT VENTILATION, VENTILATE, VENTILATOR
VERT VERTICAL
VEST VESTIBULE
VFVI VENDOR FURNISHED VENDOR
INSTALLED
VG VERTICAL GRAIN
VIB VIBRATION
VIF VERIFY IN FIELD
VNR VENEER
VOL VOLUME
VP VENEER PLASTER
VWC VINYL WALL COVERING
W
W WATTS, WIDE, WEST, WASTE, WATER
W/ WITH
W/O WITHOUT
WB WHITE BOARD, WOOD BASE
WC WATER CLOSET
WD WOOD
WDW WINDOW
WF WIDE FLANGE (STEEL). wOOD FLOORING
WG WALL GRILL
WGL WIRE GLASS
WH WALL HUNG
WK WORK
WL WATER LINE
WP WATERPROOF, WEATHERPROOF
WPM WATERPROOF MEMBRANE
WPNL WOOD PANELING
WR WASTE RECEPTACLE, WATER
REPELLANT, WATER RESISTANT
WRB WARDROBE
WS WOOD SCREW, WATERSTOP,
WEATHERSTRIP
WSCT WAINSCOT
WT WEIGHT, WATERTIGHT, WINDOW
TREATMENT
WWF WELDED WIRE FABRIC
Y
YD YARD, YARD DRAIN
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RCWY RACEWAY
RD ROOF DRAIN, ROAD
REC RECESS, RECEIVING
RECEPT RECEPTACLE, RECEPTION
RECIRC RECIRCULATION
RECT RECTANGULAR
REF REFERENCE, REFRIGERATOR
REG REGULATOR, REGLET, REGISTER
REINF REINFORCE(D)(ING)
REQD REQUIRED
RES RESINOUS (WALL OR FLOORING)
RESIL RESILIENT
RET RETURN
REV REVERSE, REVISE, REVISION
RF RADIO FREQUENCY
RFG ROOFING
RH RIGHT HAND, ROOF HATCH
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RRL RUB RAIL
RSD RECESSED SOAP DISH
RWL RAINWATER LEADER
S
S SOUTH
SAN SANITARY
SB SPLASH BLOCK
SC SOLID CORE, SHADING COEFFICIENT
SCD SEAT COVER DISPENSER
SCF STATIC CONTROL FLOORING
SCHED SCHEDULE
SCONC SEALED CONCRETE
SCR SHOWER CURTAIN ROD
SD SOAP DISPENSER, SOAP DISH, STORM
DRAIN, SMOKE DETECTOR
SE SELF EDGE
SECT SECTION
SF SQUARE FEET
SFP SPRAY-ON FIREPROOFING
SG SHARPS GUARD
SGL SINGLE
SH SHADE
SHR SHOWER
SHT SHEET
SHTG SHEATHING
SHV SHELVING
SIM SIMILAR
SK SINK, SKETCH
SKLT SKYLIGHT
SLNT SEALANT
SLR SEALER
SM SHEET METAL, SMALL
SND SANITARY NAPKIN DISPENSER
SNW SANITARY NAPKIN WASTE
SP STANDPIPE
SPC SPECIALTY CEILING
SPCL SPECIAL
SPEC SPECIFICATION, SPECIFIED
SPF SPECIALTY FLOORING
SPKLR SPRINKLER
SPKR SPEAKER
SPLY SUPPLY
SPRT SUPPORT
SPS SOLID POLYMER SURFACING
SQ SQUARE
SS SERVICE SINK, STANDING SEAM
SST STAINLESS STEEL
ST STREET, STAIR
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STM STEAM
STN STONE
STOR STORAGE
STR STRAIGHT, STRIKE, STRINGER
STRUCT STRUCTURE, STRUCTURAL
SUBFL SUBFLOOR(ING)
SURF SURFACE
SUSP SUSPENDED
SV SHEET VINYL
SYM SYMBOL
SYMM SYMMETRICAL
SYN SYNTHETIC
SYS SYSTEM
T
T TOP, TRAD, TELEPHONE (OUTLET),
TEMPERED GLASS
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TB TOWEL BAR, TACK BOARD
TEL TELEPHONE
TEMP TEMPERATURE, TEMPORARY
TER TERRAZZO
TG TEMPERED GLASS
THK THICK(NESS)
THRES THRESHOLD
THRU THROUGH
TKBD TACKBOARD
TML TERMINAL
TMPD TEMPERED
TO... TOP OF...
TOC TOP OF CURB, TOP OF CONCRETE
TOIL TOILET
TOL TOLERANCE
TOP TOPPING
TOS TOP OF STEEL, TOP OF SLAB
ML METAL LATH
MLDG MOULDING
MO MASONRY OPENING
MOD MODULAR, MODIFIED, MODIFICATION,
MODEL
MON MONITOR
MOT MOTOR
MS MACHINE SCREW, MOP SINK
MT MOUNT
MTD MOUNTED
MTG MOUNTING, MEETING
MTL METAL
MULL MULLION
N
N NORTH
NA NOT APPLICABLE
NEG NEGATIVE
NFPA NATIONAL FIRE PROTECTION ASS
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NUMBER
NOM NOMINAL
NON-COMB NON-COMBUSTIBLE
NRC NOISE REDUCTION COEFFICIENT
NS NON SLIP
NTS NOT TO SCALE
O
OA OVERALL, OUTSIDE AIR
OC ON CENTER
OD OUTSIDE DIAMETER, OUTSIDE
DIMENSION
OF OUTSIDE FACE
OFCI OWNER FURNISHED CONTRACTOR
INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OFOI OWNER FURNISHED OWNER INSTALLED
OH OVERHEAD, OVERHANG
OPER OPERATING
OPH OPPOSITE HAND
OPN(G) OPEN(ING)
OPP OPPOSITE
OZ OUNCE
P
P PHONE, POWER (OUTLET)
P-TUBE PNEUMATIC TUBE
P/THRU PASS-THROUGH
PA PUBLIC ADDRESS
PASS PASSENGER
PAT PATTERN(ED)
PAV PAVILION
PB PANIC BAR, PUSH BUTTON, PEGBOARD
PBD PARTICLE BOARD
PC PULL CHAIN
PCC PRECAST CONCRETE
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PRECAST CONCRETE PANEL
PED PEDESTAL
PERF PERFORATED
PERIM PERIMETER
PERM PERMANENT
PERP PERPENDICULAR
PG PLATE GLASS
PH PHASE
PKG PACKAGE
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLEX PLEXIGLASS
PLYWD PLYWOOD
PNL(G) PANEL(ING)
PNT PAINT(ED)
POL POLISHED
PORT PORTABLE
PP PUSH PLATE
PR PAIR
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PRESS PRESSURE
PROJ PROJECT(ION)
PROP PROPERTY
PROT PROTECTIVE
PS PRESTRESSED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT, PRESSURE TREATED
PTC PUBLIC TRANSIT CENTER
PTD PAPER TOWL DISPENSER
PTDR PAPER TOWL DISPENSER &
RECEPTACLE
PTN PARTITION
PTR PRINTER
PTS PNEUMATIC TUBE STATION
PVC POLYVINYL CHLORIDE
PVG PAVING
PWC PROTECTIVE WALL COVERING
PWR POWER
Q
QT QUARRY TILE, QUART
QTR QUATER
QTY QUANTITY
R
R RADIUS, RISER
R&S ROD AND SHELF
RAD RADIATOR
RADN RADIATION
GKT GASKET
GL GLASS, GLAZING, GLAZED
GLI GLASS (INTERIOR)
GLU LAM GLUE LAMINATED
GND GROUND
GOVT GOVERMENT
GR GRANITE
GT GROUT
GWB GYPSUM WALLBOARD
GWB/PNT GYPSUM WALLBOARD PAINTED
GYP GYPSUM
H
H HIGH, HEIGHT
HB HOSE BIB
HC HOSE CABINET, HOLLOW CORE
HD HAND DRYER
HDBD HARDBOARD
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEX HEXAGONAL
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HORSE POWER, HIGH PRESSURE, HIGH
POINT
HPC HIGH PERFORMANCE COATING
HR HOUR
HRL HANDRAIL
HS HOOK STRIP, HIGH STRENGTH
HSKPG HOUSEKEEPING
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING / VENTILATION / AIR
CONDITIONING
HVC HOSE VALVE CABINET
HW HOT WATER, HARDWARE
HWY HIGHWAY
HYD HYDRANT
I
IBC INTERNATIONAL BUILDING CODE
ICB INTEGRAL COVER BASE
ID INSIDE DIAMETER, INSIDE DIMENSION,
IDENTIFICATION
IE INVERT ELEVATION, THAT IS
IN INCH
INCAND INCANDESCENT
INCL INCLUDE(ING)
IND INDUSTRIAL
INFO INFORMATION
INL INLET
INSTL INSTALLATION, INSTALL
INSUL INSULATE(D)(ING)(ION)
INT INTERIOR
INTER INTERSECTION, INTERMEDIATE
INV INVERT
ISOL ISOLATION
J
J-BOX JUNCTION BOX
JAN JANITOR
JT JOINT
K
KO KNOCK OUT
KPL KICK PLATE
KS KNEE SPACE
L
L LEAD
L&P LATH AND PLASTER
LA LABORATORY AIR
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LB LAG BOLT, POUND
LBR LUMBER
LF LINEAR FOOT
LIN LINEAR
LKR LOCKER
LPT LOW POINT
LT LIGHT
LTG LIGHTING
LTWT LIGHT WEIGHT
LV LABORATORY VACUUM, LOW VOLTAGE
LVR LOUVER
M
M&S MIRROR AND SHELF
MACH MACHINE
MAINT MAINTENANCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT, MARKER BOARD
MBL MARBLE
MBR MEMBER
MC MEDICINE CABINET, MINERAL CORE
MDF MEDIUM DENSITY FIBERBOARD
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MET METAL
MEZZ MEZZANINE
MFR MANUFACTURER
MGR MANAGER
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
DEG DEGREE
DEMO DEMOLISH, DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIAG DIAGONAL
DIAM DIAMETER
DIFF DIFFUSER, DIFFERENCE
DIM DIMENSION
DIR DIRECTOR, DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVISION, DIVIDER
DL DEAD LOAD
DN DOWN
DO DITTO
DPG DECORATIVE PLASTIC GLAZING
DR DOOR, DRAIN, DRIVE
DS DOWNSPOUT
DSPL DISPOSAL
DTL DETAIL
DW DISHWASHER
DWG DRAWING
DWR DRAWER
DX DUPLEX
E
E EAST, ELECTRICAL (OUTLET)
EA EACH
EG END GUARD
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION (GRADE)
ELEC ELECTRIC(AL)
ELEV ELEVATOR, ELEVATION
ELIM ELIMINATE
EM ENTRY MAT
EMER EMERGENCY
EMP EMERGENCY POWER
ENAM ENAMEL(ED)
ENCL ENCLOSED, ENCLOSURE
ENGR ENGINEER
ENTR ENTRANCE
EPOX EPOXY FLOORING
EPOX PNT EPOXY PAINT
EPRF EXPLOSION PROOF
EQ EQUAL, EARTHQUAKE
EQJ EARTHQUAKE JOINT
EQUIP EQUIPMENT
ESCR ESCALATOR
EST ESTIMATE
ETC ET CETERA
EW EYE WASH, EACH WAY
EWC ELECTRIC WATER COOLER
EX EXISTING
EXAM EXAMINATION
EXC EXCAVATED, EXCAVATION, EXCAVATE
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED, EXPANSION
EXP BT EXPANSION BOLT
EXT EXTERIOR
F
F FAHRENHEIT, FILE DRAWER
F TO F FACE TO FACE
FA FIRE ALARM
FAB FABRICATE, FABRICATOR, FABRIC
FACIL FACILITY
FB FLAT BAR
FBD FIBERBOARD
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FACTORY FINISH
FH FIRE HYDRANT, FUME HOOD, FLAT HEAD
FHC FIRE HOSE CABINET
FHEC FIRE HOSE AND EXTINGUISHER CABINET
FIN FINISH(ED)
FL FLOOR LINE, FLOOR
FLASH FLASHING
FLEX FLEXIBLE
FLR FLOOR(ING)
FLUOR FLUORESCENT
FO... FACE OF...
FP FIREPROOF(ING) FULL PENETRATION
FR FRAME
FREQ FREQUENCY
FRMG FRAMING
FRTW FIRE RETARDANT TREATED WOOD
FS FULL SIZE, FLOOR SINK
FSS FOLDING SHOWER SEAT
FT FOOT, FEET
FTG FOOTING
FURR FURRING
FUT FUTURE
FWC FABRIC WALL COVERING
G
G GAS (OUTLET)
GA GAUGE, GAGE
GAL GALLON
GALV GALVANIZE(D)
GALV STL GALANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN GENERAL
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GFRP GLASS FIBER REINFORCED PLASTER
A
AB ANCHOR BOLT
AC ALTERNATING CURRENT
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN, ACCESS DOOR
ADA AMERICANS WITH DISABILITIES ACT
ADDL ADDITIONAL
ADDM ADDENDUM
ADDN ADDITION
ADJ ADJUSTABLE / ADJACENT
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFP ACOUSTIC FABRIC PANEL
AGGR AGGREGATE
AHU AIR HANDLING UNIT
ALT ALTERNATE, ALTERATION
ALUM ALUMINUM
AMP AMPERES
AMPL AMPLIFIER
ANCH ANCHOR
ANOD ANODIZER
AP ACCESS PANEL
APPVD APPROVED
APROX APPROXIMATE(LY)
ARCH ARCHITECT(URAL)
ASPH ASPHALT
ASST ASSIST(ANT)
ASSY ASSEMBLY
AST ASTRAGAL
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AWC ACOUSTIC WALL PANEL
B
BAL BALANCE
BCS BABY CHANGING STATION
BD BOARD
BITUM BITUMINOUS
BL BUILDING LINE
BLDG BUILDING
BLK(G) BLOCK(ING)
BLKT BLANKET
BLVD BOULEVARD
BM BENCHMARK, BEAM
BO BOTTOM OF
BOT BOTTOM
BRKT BRACKET
BSMT BASEMENT
BTU BRITISH THERMAL UNIT
BUR BUILT UP ROOFING
BW BOTTOM OF WALL, BOTH WAYS
C
CAB CABINET
CAP CAPACITY
CB CATCH BASIN, CHALKBOARD
CCTV CLOSED CIRCUIT TV
CD CUP DISPENSER
CER CERAMIC
CFCI CONTRACTOR FURNISHED &
CONTRACTOR INSTALLED
CG CORNER GUARD, CENTER OF GRAVITY
CH COAT HOOK
CHEM CHEMICAL, CHEMISTRY
CIP CAST IN PLACE (CONCRETE)
CIR CIRCLE
CIRC CIRCULATION
CJ CONTROL JOINT
CL CENTERLINE, CLEARANCE
CLG CEILING
CLO CLOSET
CLR CLEAR, COLOR
CLS CLOSER
CMPTR COMPUTER
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMB COMBINATION, COMBUSTIBLE
COMM COMMUNICATION
COMP COMPOSITE(ION), COMPOSED
COMP COMPRESS(ED)(ION),
COMPACT(OR)(ED)(ION)
CONC CONCRETE
COND CONDUIT, CONDITION
CONF CONFERENCE
CONN CONNECT(ION)
CONST CONSTRUCTION
CONT CONTINUE, CONTINUOUS
CONTR CONTRACTOR
CONV CONVENTIONAL, CONVECTOR
COORD COORDINATE
CORR CORRIDOR
CPT CARPET
CPTT CARPET TILE
CRL CHAIR RAIL
CRS COLD ROLLED STEEL
CSK COUNTERSUNK, COUNTERSINK
CSWK CASEWORK
CT CERAMIC TILE
CTR CENTER
CTRL CONTROL
CU CUBIC
CW COLD WATER, CLOCKWISE
CY CUBIC YARD
D
D DEEP, DATA (OUTLET)
DB DECIBEL
DBL DOUBLE
A B C D F G H
IE
A3.0.00
163156
TYP
164164
168101
A B C D F G H
IE
A3.0.00
A B C D F G H
IE
A3.0.00
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
ISOMETRIC DEMOLITION LEGEND
PREVIOUSLY COMPLETED
PHASE(S)
DEMO THIS PHASE
EXISTING TO REMAIN
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:1
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
DEMO - PHASE 1
Project Number
DSS
VGD
08/18/14
VGD
A1.0.01 4 35A1.0.01
DEMO - PHASE 1 - ISOMETRIC5
1/16" = 1'-0"A1.0.01
DEMO PLAN - PHASE 1 - LEVEL 11
1/16" = 1'-0"A1.0.01
DEMO PLAN - PHASE 1 - LEVEL 22
1/16" = 1'-0"A1.0.01
DEMO PLAN - PHASE 1 - LEVEL 33
SHEET KEY NOTES
101 DEMO EXISTING THIN BRICK VENEER, RIGID INSULATION, AND BATT INSULATION (WHERE OCCURS). VERIFY CONDITION OF
EXISTING METAL FRAMING TO REMAIN
156 EXISTING METAL PANELS TO REMAIN. REFINISH TO MATCH EXISTING METAL PANEL REFINISHING PT-1 IN PHASE 1 NEW WORK
163 EXISTING LOUVER TO REMAIN. REFINISH TO MATCH ADJACENT METAL PANEL REFINISHING PT-1 IN PHASE 1 NEW WORK
164 EXISTING STOREFRONT DOOR AND SIDELITE FILLER PANEL TO TO BE RELOCATED. SIDELITE FILLER PANEL TO RELOCATE TO EAST JAMB TO SHIFT ENTRANCE DOOR TO EAST TO MAKE ROOM FOR NEW METAL WALL PANEL ASSEMBLY
168 EXISTING BRICK VENEER SITE WALL TO REMAIN
IE
A3.0.00
A3.0.00 101101
A B C D F G H
IE
A3.0.00
A3.0.00 101101154
TYP
A B C D F G H
IE
A3.0.00
A3.0.00 101101154
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
ISOMETRIC DEMOLITION LEGEND
PREVIOUSLY COMPLETED
PHASE(S)
DEMO THIS PHASE
EXISTING TO REMAIN
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:2
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
DEMO - PHASE 2
Project Number
DSS
VGD
08/18/14
VGD
A1.0.02 5 35A1.0.02
DEMO - PHASE 2 - ISOMETRIC4
1/16" = 1'-0"A1.0.02
DEMO PLAN - PHASE 2 - LEVEL 11
1/16" = 1'-0"A1.0.02
DEMO PLAN - PHASE 2 - LEVEL 22
1/16" = 1'-0"A1.0.02
DEMO PLAN - PHASE 2 - LEVEL 33
SHEET KEY NOTES
101 DEMO EXISTING THIN BRICK VENEER, RIGID INSULATION, AND BATT INSULATION (WHERE OCCURS). VERIFY CONDITION OF
EXISTING METAL FRAMING TO REMAIN
154 EXISTING STRUCTURE SUPPORT WRAPPED IN METAL PANELS TO REMAIN. REFINISH TO MATCH ADJACENT METAL PANEL REFINISHING PT-1 IN PHASE 1 NEW WORK. SEE ALSO DETAIL 2/A8.0.01 FOR TYPICAL METAL PANEL PENETRATION
IE
A3.0.00
A3.0.00
A B C D F G H
IE
A3.0.00
A3.0.00
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
A B C D F G H
IE
A3.0.00
A3.0.00
101101
ISOMETRIC DEMOLITION LEGEND
PREVIOUSLY COMPLETED
PHASE(S)
DEMO THIS PHASE
EXISTING TO REMAIN
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:3
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
DEMO - PHASE 3
Project Number
DSS
VGD
08/18/14
VGD
A1.0.03 6 35
A1.0.03
DEMO - PHASE 3 - ISOMETRIC1
1/16" = 1'-0"A1.0.03
DEMO PLAN - PHASE 3 - LEVEL 22
1/16" = 1'-0"A1.0.03
DEMO PLAN - PHASE 3 - LEVEL 33
1/16" = 1'-0"A1.0.03
DEMO PLAN - PHASE 3 - ROOF4
SHEET KEY NOTES
101 DEMO EXISTING THIN BRICK VENEER, RIGID INSULATION, AND BATT INSULATION (WHERE OCCURS). VERIFY CONDITION OF
EXISTING METAL FRAMING TO REMAIN
153 EXISTING WINDOWS TO REMAIN
174 EXISTING MECH EQUIPMENT TO REMAIN. TO BE REFINISHED TO MATCH EXISTING METAL PANEL REFINISHING PT-1 IN PHASE 1
NEW WORK
IE
A B C D F G H
IE
A3.0.00
A B C D F G H
IE
A3.0.00
A B C D
A3.0.00
101101
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
ISOMETRIC DEMOLITION LEGEND
PREVIOUSLY COMPLETED
PHASE(S)
DEMO THIS PHASE
EXISTING TO REMAIN
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:4
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
DEMO - PHASE 4
Project Number
DSS
VGD
08/18/14
VGD
A1.0.04 7 35
A1.0.04
DEMO - PHASE 4 - ISOMETRIC5
1/16" = 1'-0"A1.0.04
DEMO PLAN - PHASE 4 - LEVEL 11
1/16" = 1'-0"A1.0.04
DEMO PLAN - PHASE 4 - LEVEL 22
1/16" = 1'-0"A1.0.04
DEMO PLAN - PHASE 4 - LEVEL 33
1/16" = 1'-0"A1.0.04
DEMO PLAN - PHASE 4 - ROOF4
SHEET KEY NOTES
101 DEMO EXISTING THIN BRICK VENEER, RIGID INSULATION, AND BATT INSULATION (WHERE OCCURS). VERIFY CONDITION OF
EXISTING METAL FRAMING TO REMAIN
157 EXISTING LOADING DOCK DOORS AND JAMBS TO REMAIN. REMOVE EXISTING BUMPERS, LEVELERS, AND ASSOCIATED HARDWARE PRIOR TO WALL VENEER DEMOLITION AND REINSTALL WITH BLOCKING AS REQUIRED WITH NEW METAL SIDING PANELS PER NEW WORK PAHSE 4. REFINISH DOOR PANEL, JAMBS, AND EXISTING HARDWARE TO REMAIN TO MATCH EXISTING
METAL PANEL REFINISHING PT-1 IN PHASE 1 NEW WORK
161 REMOVE EXISTING DUCTWORK AND MECHANICAL EQUIPMENT FOR WALL VENEER DEMO AND REINSTALLED AFTER NEW WORK IS COMPLETE. REFLASH ALL EXISTING WALL PENETRATIONS AND RESEAL DUCTWORK AS REQUIRED
169 EXISTING STOREFRONT VESTIBULE TO REMAIN
J L
171172
J L
172 171
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
ISOMETRIC DEMOLITION LEGEND
PREVIOUSLY COMPLETED
PHASE(S)
DEMO THIS PHASE
EXISTING TO REMAIN
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:4
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
DEMO - PHASE 5
Project Number
DSS
VGD
08/18/14
VGD
A1.0.05 8 35
A1.0.05
DEMO - PHASE 5 - ISOMETRIC1
1/16" = 1'-0"A1.0.05
DEMO PLAN - PHASE 5 - LEVEL 12
1/16" = 1'-0"A1.0.05
DEMO PLAN - PHASE 5 - ROOF PLAN3
SHEET KEY NOTES
101 DEMO EXISTING THIN BRICK VENEER, RIGID INSULATION, AND BATT INSULATION (WHERE OCCURS). VERIFY CONDITION OF
EXISTING METAL FRAMING TO REMAIN
104 DEMO EXISTING THRU WALL SCUPPER, CONDUCTOR HEAD, AND DOWNSPOUT, TO BE REPLACED WITH NEW WORK
105 DEMO EXISTING GUTTER AND DOWNSPOUT. TO BE REPLACED IN NEW WORK.
156 EXISTING METAL PANELS TO REMAIN. REFINISH TO MATCH EXISTING METAL PANEL REFINISHING PT-1 IN PHASE 1 NEW WORK
158 EXISTING MECHANICAL CATWALK TO REMAIN
159 EXISTING ROOF TOP UNIT TO REMAIN
161 REMOVE EXISTING DUCTWORK AND MECHANICAL EQUIPMENT FOR WALL VENEER DEMO AND REINSTALLED AFTER NEW WORK IS COMPLETE. REFLASH ALL EXISTING WALL PENETRATIONS AND RESEAL DUCTWORK AS REQUIRED
162 EXISTING LOUVER TO REMAIN. REFINISH TO MATCH NEW WALL PANELS. PROVIDE NEW FLASHING WITH NEW WORK
171 EXISTING WALL PENETRATION TO REMAIN
172 EXISTING ROOF DRAIN OUTLET TO REMAIN
173 EXISTING DOOR AND FRAME TO REMAIN. COORDINATE REMOVAL AND REINSTALALTION OF SECURE ACCESS KEYPAD WITH LOCATION FACILITIES MANAGER. REFINISH ENTIRE DOOR LEAF, JAMB, AND KEYPAD COVER TO MATCH ADJACENT NEW METAL
PANELS
175 EXISTING MECHANICAL ROOM TO REMAIN. REFINISH TO MATCH EXISTING METAL PANEL REFINISHING PT-1 IN PHASE 1 NEW
WORK
UP
A3.1.00
A3.1.01
A3.1.01
A B C D F G H
IE
A3.1.00
A3.1.02
A3.1.02
A3.1.02
A3.1.02
A3.1.00
156 163
A8.0.00
SIM
A8.0.00
SIM
A8.0.00
TYP
156156
A8.0.00
250 251
A8.0.00
TYP
A8.0.00
TYP
156156156
TYP
168168
153 153 174
A8.0.00
TYP
TYP
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
GENERAL NOTES
SHEET KEYNOTES
REFERENCE LEGEND
1. FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ARCHITECT IF FIELD CONDITIONS RESULTING FROM
EXPOSED DEMO WORK
2. REMOVE AND REATTACH EXISTING FIXTURES ATTACHED
TO WALL AS REQUIRED FOR DEMOLITION AND NEW
WORK; INCLUDING BUT NOT LIMITED TO ACCESS
KEYPAD, LIGHTS, ALARMS, SIGNS, AND CONDUIT
3. RESEAL ALL PENETRATIONS OR OPENINGS THROUGH
WALLS OR SOFFITS TO MAINTAIN WEATHERTIGHT
NATURE OF ENCLOSURE
4. DETAILS FOR VERTICAL ORIENTATION METAL PANELS
ARE TYPICAL IN NATURE AND ARE TO ENSURE
WEATHERTIGHTNESS, PLEASE ALSO REFER TO METAL
PANEL MANUFACTURER'S SPECIFIC INSTRUCTIONS AND
DETAILS
5. METAL PANEL INSTALLER SHALL ENGINEER
COMPATIBLE FASTENER AND GIRT BASED ON EXISTING
CONDITIONS AND SELECTED METAL PANEL
MANUFACTURER
6. SEE DRAWING SERIES A1.0.00 FOR EXTENT OF DEMO
WORK
7. SEE DRAWING A2.0.00 FOR OVERALL PHASING OF NEW
WORK
8. SEE DRAWING A2.0.00 FOR EXTERIOR FINISH
SCHEDULE
9. SEE DRAWING SERIES A2.0.00 FOR NEW WORK
10. SEE DRAWING SERIES A3.0.00 FOR NEW WORK
ELEVATIONS AND SECTIONS
11. SEE DRAWING SERIES A8.00 FOR NEW WORK DETAILS
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:5
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
PROPOSED PLAN - PHASE 1 - LEVEL 1
Project Number
DSS
VGD
08/18/14
VGD
A2.1.01 10 35
1/8" = 1'-0"A2.1.01
PROPOSED PLAN - PHASE 1 - LEVEL 11
103 DEMO EXISTING WINDOW FLASHING SET IN SEALANT
153 EXISTING WINDOWS TO REMAIN
156 EXISTING METAL PANELS TO REMAIN. REFINISH TO
MATCH EXISTING METAL PANEL REFINISHING PT-1 IN
PHASE 1 NEW WORK
157 EXISTING LOADING DOCK DOORS AND JAMBS TO
REMAIN. REMOVE EXISTING BUMPERS, LEVELERS,
AND ASSOCIATED HARDWARE PRIOR TO WALL
VENEER DEMOLITION AND REINSTALL WITH BLOCKING
AS REQUIRED WITH NEW METAL SIDING PANELS PER
NEW WORK PAHSE 4. REFINISH DOOR PANEL, JAMBS,
AND EXISTING HARDWARE TO REMAIN TO MATCH
EXISTING METAL PANEL REFINISHING PT-1 IN PHASE 1
NEW WORK
163 EXISTING LOUVER TO REMAIN. REFINISH TO MATCH
ADJACENT METAL PANEL REFINISHING PT-1 IN PHASE
1 NEW WORK
165 EXISTING DOOR, JAMB, AND HARDWARE TO REMAIN.
REFINISH ENTIRE DOOR LEAF AND JAMB TO MATCH
ADJACENT METAL PANEL REFINISHING PT-1 IN PHASE
1 NEW WORK
167 EXISTING STUCCO FACED COLUMN TO REMAIN
168 EXISTING BRICK VENEER SITE WALL TO REMAIN
174 EXISTING MECH EQUIPMENT TO REMAIN. TO BE
REFINISHED TO MATCH EXISTING METAL PANEL
REFINISHING PT-1 IN PHASE 1 NEW WORK
218 NEW METAL WALL PANEL TRIM, FINISH TO MATCH
NEW METAL WALL PANELS. SEE ALSO ELEVATIONS
AND DETAILS
250 RELOCATED STOREFRONT INFILL PANEL AND
MULLION
251 RELOCATED STOREFRONT ENTRANCE DOOR AND
HARDWARE
A3.1.00
A3.1.01
A3.1.01
A B C D F G H
IE
A3.1.00
A3.1.02
A3.1.02
A3.1.02
A3.1.02
A3.1.00
A8.0.00
SIM
A8.0.00
SIM
A8.0.00
TYP
A8.0.00
TYP
A8.0.00
TYP
156156156
156156
154 154 154 154
156156
A8.0.00
TYP
168168
A8.0.00
SIM
A8.0.00
TYP
TYP
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
GENERAL NOTES
SHEET KEYNOTES
REFERENCE LEGEND
1. FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ARCHITECT IF FIELD CONDITIONS RESULTING FROM
EXPOSED DEMO WORK
2. REMOVE AND REATTACH EXISTING FIXTURES ATTACHED
TO WALL AS REQUIRED FOR DEMOLITION AND NEW
WORK; INCLUDING BUT NOT LIMITED TO ACCESS
KEYPAD, LIGHTS, ALARMS, SIGNS, AND CONDUIT
3. RESEAL ALL PENETRATIONS OR OPENINGS THROUGH
WALLS OR SOFFITS TO MAINTAIN WEATHERTIGHT
NATURE OF ENCLOSURE
4. DETAILS FOR VERTICAL ORIENTATION METAL PANELS
ARE TYPICAL IN NATURE AND ARE TO ENSURE
WEATHERTIGHTNESS, PLEASE ALSO REFER TO METAL
PANEL MANUFACTURER'S SPECIFIC INSTRUCTIONS AND
DETAILS
5. METAL PANEL INSTALLER SHALL ENGINEER
COMPATIBLE FASTENER AND GIRT BASED ON EXISTING
CONDITIONS AND SELECTED METAL PANEL
MANUFACTURER
6. SEE DRAWING SERIES A1.0.00 FOR EXTENT OF DEMO
WORK
7. SEE DRAWING A2.0.00 FOR OVERALL PHASING OF NEW
WORK
8. SEE DRAWING A2.0.00 FOR EXTERIOR FINISH
SCHEDULE
9. SEE DRAWING SERIES A2.0.00 FOR NEW WORK
10. SEE DRAWING SERIES A3.0.00 FOR NEW WORK
ELEVATIONS AND SECTIONS
11. SEE DRAWING SERIES A8.00 FOR NEW WORK DETAILS
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:5
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
PROPOSED PLAN - PHASE 1 - LEVEL 2
Project Number
DSS
VGD
08/18/14
VGD
A2.1.02 11 35
1/8" = 1'-0"A2.1.02
PROPOSED PLAN - PHASE 1 - LEVEL 21
103 DEMO EXISTING WINDOW FLASHING SET IN SEALANT
153 EXISTING WINDOWS TO REMAIN
154 EXISTING STRUCTURE SUPPORT WRAPPED IN METAL
PANELS TO REMAIN. REFINISH TO MATCH ADJACENT
METAL PANEL REFINISHING PT-1 IN PHASE 1 NEW
WORK. SEE ALSO DETAIL 2/A8.0.01 FOR TYPICAL
METAL PANEL PENETRATION
156 EXISTING METAL PANELS TO REMAIN. REFINISH TO
MATCH EXISTING METAL PANEL REFINISHING PT-1 IN
PHASE 1 NEW WORK
167 EXISTING STUCCO FACED COLUMN TO REMAIN
168 EXISTING BRICK VENEER SITE WALL TO REMAIN
218 NEW METAL WALL PANEL TRIM, FINISH TO MATCH
NEW METAL WALL PANELS. SEE ALSO ELEVATIONS
AND DETAILS
A3.1.01
A3.1.01
A B C D F G H
IE
A3.1.00
A3.1.02
A3.1.02
A3.1.02
A3.1.02
A8.0.00
SIM
A8.0.00
TYP
A8.0.00
TYP
156156
A8.0.00
TYP
154 154 154 154 154
156156
A8.0.00
TYP
A8.0.00
SIM
A8.0.00
168168
A8.0.00
SIM
A8.0.00
TYP
A8.0.00
SIM
A8.0.01
TYP
218TYP
GENERAL NOTES
SHEET KEYNOTES
REFERENCE LEGEND
1. FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ARCHITECT IF FIELD CONDITIONS RESULTING FROM
EXPOSED DEMO WORK
2. REMOVE AND REATTACH EXISTING FIXTURES ATTACHED
TO WALL AS REQUIRED FOR DEMOLITION AND NEW
WORK; INCLUDING BUT NOT LIMITED TO ACCESS
KEYPAD, LIGHTS, ALARMS, SIGNS, AND CONDUIT
3. RESEAL ALL PENETRATIONS OR OPENINGS THROUGH
WALLS OR SOFFITS TO MAINTAIN WEATHERTIGHT
NATURE OF ENCLOSURE
4. DETAILS FOR VERTICAL ORIENTATION METAL PANELS
ARE TYPICAL IN NATURE AND ARE TO ENSURE
WEATHERTIGHTNESS, PLEASE ALSO REFER TO METAL
PANEL MANUFACTURER'S SPECIFIC INSTRUCTIONS AND
DETAILS
5. METAL PANEL INSTALLER SHALL ENGINEER
COMPATIBLE FASTENER AND GIRT BASED ON EXISTING
CONDITIONS AND SELECTED METAL PANEL
MANUFACTURER
6. SEE DRAWING SERIES A1.0.00 FOR EXTENT OF DEMO
WORK
7. SEE DRAWING A2.0.00 FOR OVERALL PHASING OF NEW
WORK
8. SEE DRAWING A2.0.00 FOR EXTERIOR FINISH
SCHEDULE
9. SEE DRAWING SERIES A2.0.00 FOR NEW WORK
10. SEE DRAWING SERIES A3.0.00 FOR NEW WORK
ELEVATIONS AND SECTIONS
11. SEE DRAWING SERIES A8.00 FOR NEW WORK DETAILS
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:5
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
PROPOSED PLAN - PHASE 1 - LEVEL 3
Project Number
DSS
VGD
08/18/14
VGD
A2.1.03 12 35
1/8" = 1'-0"A2.1.03
PROPOSED PLAN - PHASE 1 - LEVEL 31
103 DEMO EXISTING WINDOW FLASHING SET IN SEALANT
153 EXISTING WINDOWS TO REMAIN
154 EXISTING STRUCTURE SUPPORT WRAPPED IN METAL
PANELS TO REMAIN. REFINISH TO MATCH ADJACENT
METAL PANEL REFINISHING PT-1 IN PHASE 1 NEW
WORK. SEE ALSO DETAIL 2/A8.0.01 FOR TYPICAL
METAL PANEL PENETRATION
156 EXISTING METAL PANELS TO REMAIN. REFINISH TO
MATCH EXISTING METAL PANEL REFINISHING PT-1 IN
PHASE 1 NEW WORK
168 EXISTING BRICK VENEER SITE WALL TO REMAIN
218 NEW METAL WALL PANEL TRIM, FINISH TO MATCH
NEW METAL WALL PANELS. SEE ALSO ELEVATIONS
AND DETAILS
A3.1.01
A3.1.01
A B C D F G H
IE
A3.1.00
A3.1.02
A3.1.02
A3.1.02
A3.1.02
156156 156156
156156
156 163
156 163
GENERAL NOTES
SHEET KEYNOTES
REFERENCE LEGEND
1. FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ARCHITECT IF FIELD CONDITIONS RESULTING FROM
EXPOSED DEMO WORK
2. REMOVE AND REATTACH EXISTING FIXTURES ATTACHED
TO WALL AS REQUIRED FOR DEMOLITION AND NEW
WORK; INCLUDING BUT NOT LIMITED TO ACCESS
KEYPAD, LIGHTS, ALARMS, SIGNS, AND CONDUIT
3. RESEAL ALL PENETRATIONS OR OPENINGS THROUGH
WALLS OR SOFFITS TO MAINTAIN WEATHERTIGHT
NATURE OF ENCLOSURE
4. DETAILS FOR VERTICAL ORIENTATION METAL PANELS
ARE TYPICAL IN NATURE AND ARE TO ENSURE
WEATHERTIGHTNESS, PLEASE ALSO REFER TO METAL
PANEL MANUFACTURER'S SPECIFIC INSTRUCTIONS AND
DETAILS
5. METAL PANEL INSTALLER SHALL ENGINEER
COMPATIBLE FASTENER AND GIRT BASED ON EXISTING
CONDITIONS AND SELECTED METAL PANEL
MANUFACTURER
6. SEE DRAWING SERIES A1.0.00 FOR EXTENT OF DEMO
WORK
7. SEE DRAWING A2.0.00 FOR OVERALL PHASING OF NEW
WORK
8. SEE DRAWING A2.0.00 FOR EXTERIOR FINISH
SCHEDULE
9. SEE DRAWING SERIES A2.0.00 FOR NEW WORK
10. SEE DRAWING SERIES A3.0.00 FOR NEW WORK
ELEVATIONS AND SECTIONS
11. SEE DRAWING SERIES A8.00 FOR NEW WORK DETAILS
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
A2.5.01
A2.5.01
A2.5.01
J L
175175
NOTE:
REFINISHING OF ROOF TOP MECHANICAL ROOM AND SECTION
OF SCREEN WALL ON EAST ELEVATION ARE PART OF PHASE
1 REFINISHING
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:5
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
PROPOSED PLAN - PHASE 1 - ROOF
Project Number
DSS
VGD
08/18/14
VGD
A2.1.04 13 35
1/8" = 1'-0"A2.1.04
PROPOSED PLAN - PHASE 1 - ROOF1
156 EXISTING METAL PANELS TO REMAIN. REFINISH TO
MATCH EXISTING METAL PANEL REFINISHING PT-1
IN PHASE 1 NEW WORK
161 REMOVE EXISTING DUCTWORK AND MECHANICAL
EQUIPMENT FOR WALL VENEER DEMO AND
REINSTALLED AFTER NEW WORK IS COMPLETE.
REFLASH ALL EXISTING WALL PENETRATIONS AND
RESEAL DUCTWORK AS REQUIRED
163 EXISTING LOUVER TO REMAIN. REFINISH TO
MATCH ADJACENT METAL PANEL REFINISHING PT-1
IN PHASE 1 NEW WORK
165 EXISTING DOOR, JAMB, AND HARDWARE TO
REMAIN. REFINISH ENTIRE DOOR LEAF AND JAMB
TO MATCH ADJACENT METAL PANEL REFINISHING
PT-1 IN PHASE 1 NEW WORK
175 EXISTING MECHANICAL ROOM TO REMAIN.
REFINISH TO MATCH EXISTING METAL PANEL
REFINISHING PT-1 IN PHASE 1 NEW WORK
201 NEW VERTICAL CONCEALED FASTENER METAL
PANELS ATTACHED TO RAINSCREEN SYSTEM OF
3/4" METAL GIRTS OVER 2.5" POLY ISO RIGID
INSULATION SHEATHING WITH INTEGRAL
AIR/WEATHER BARRIER
1/8" = 1'-0"A2.1.04
PROPOSED PLAN - PHASE 1 - BOILER ROOF2
UPUPUP
GENERAL NOTES
SHEET KEYNOTES
REFERENCE LEGEND
1. FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ARCHITECT IF FIELD CONDITIONS RESULTING FROM
EXPOSED DEMO WORK
2. REMOVE AND REATTACH EXISTING FIXTURES ATTACHED
TO WALL AS REQUIRED FOR DEMOLITION AND NEW
WORK; INCLUDING BUT NOT LIMITED TO ACCESS
KEYPAD, LIGHTS, ALARMS, SIGNS, AND CONDUIT
3. RESEAL ALL PENETRATIONS OR OPENINGS THROUGH
WALLS OR SOFFITS TO MAINTAIN WEATHERTIGHT
NATURE OF ENCLOSURE
4. DETAILS FOR VERTICAL ORIENTATION METAL PANELS
ARE TYPICAL IN NATURE AND ARE TO ENSURE
WEATHERTIGHTNESS, PLEASE ALSO REFER TO METAL
PANEL MANUFACTURER'S SPECIFIC INSTRUCTIONS AND
DETAILS
5. METAL PANEL INSTALLER SHALL ENGINEER
COMPATIBLE FASTENER AND GIRT BASED ON EXISTING
CONDITIONS AND SELECTED METAL PANEL
MANUFACTURER
6. SEE DRAWING SERIES A1.0.00 FOR EXTENT OF DEMO
WORK
7. SEE DRAWING A2.0.00 FOR OVERALL PHASING OF NEW
WORK
8. SEE DRAWING A2.0.00 FOR EXTERIOR FINISH
SCHEDULE
9. SEE DRAWING SERIES A2.0.00 FOR NEW WORK
10. SEE DRAWING SERIES A3.0.00 FOR NEW WORK
ELEVATIONS AND SECTIONS
11. SEE DRAWING SERIES A8.00 FOR NEW WORK DETAILS
A B C D F G H
IE
A3.2.02
A3.2.02
A3.2.02
A3.2.00
A3.2.00
A3.2.00
TYP
168168 205
A8.0.00
SIM
A8.0.00
SIM
TYP
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:5
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
PROPOSED PLAN - PHASE 2 - LEVEL 1
Project Number
DSS
VGD
08/18/14
VGD
A2.2.01 14 35
167 EXISTING STUCCO FACED COLUMN TO REMAIN
168 EXISTING BRICK VENEER SITE WALL TO REMAIN
205 NEW VERTICAL CONCEALED FASTENER METAL
PANELS ATTACHED TO 3/4" METAL GIRTS OVER 5/8"
EXTERIOR SHEATHING AND ADDITIONAL NEW
METAL FURRING ON EXISTING METAL FRAMING.
PROVIDE BUTYL TAPE BETWEEN DISSIMILAR METAL
COMPONENTS. PROVIDE ADDITIONAL METAL
FURRING ON EXTERIOR SIDE OF SCREENWALL TO
ENSURE FINAL METAL PANEL FINISH ALIGNS WITH
PHASE 1 METAL PANEL FINISH
218 NEW METAL WALL PANEL TRIM, FINISH TO MATCH
NEW METAL WALL PANELS. SEE ALSO ELEVATIONS
AND DETAILS
1/8" = 1'-0"A2.2.01
PROPOSED PLAN - PHASE 2 - LEVEL 11
IE
A3.2.02
A3.2.02
A3.2.02
A3.2.00
A3.2.00
A3.2.00
TYP
A8.0.00
SIM
A8.0.00
SIM
A8.0.00
SIM
205205
TYP
GENERAL NOTES
SHEET KEYNOTES
REFERENCE LEGEND
1. FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ARCHITECT IF FIELD CONDITIONS RESULTING FROM
EXPOSED DEMO WORK
2. REMOVE AND REATTACH EXISTING FIXTURES ATTACHED
TO WALL AS REQUIRED FOR DEMOLITION AND NEW
WORK; INCLUDING BUT NOT LIMITED TO ACCESS
KEYPAD, LIGHTS, ALARMS, SIGNS, AND CONDUIT
3. RESEAL ALL PENETRATIONS OR OPENINGS THROUGH
WALLS OR SOFFITS TO MAINTAIN WEATHERTIGHT
NATURE OF ENCLOSURE
4. DETAILS FOR VERTICAL ORIENTATION METAL PANELS
ARE TYPICAL IN NATURE AND ARE TO ENSURE
WEATHERTIGHTNESS, PLEASE ALSO REFER TO METAL
PANEL MANUFACTURER'S SPECIFIC INSTRUCTIONS AND
DETAILS
5. METAL PANEL INSTALLER SHALL ENGINEER
COMPATIBLE FASTENER AND GIRT BASED ON EXISTING
CONDITIONS AND SELECTED METAL PANEL
MANUFACTURER
6. SEE DRAWING SERIES A1.0.00 FOR EXTENT OF DEMO
WORK
7. SEE DRAWING A2.0.00 FOR OVERALL PHASING OF NEW
WORK
8. SEE DRAWING A2.0.00 FOR EXTERIOR FINISH
SCHEDULE
9. SEE DRAWING SERIES A2.0.00 FOR NEW WORK
10. SEE DRAWING SERIES A3.0.00 FOR NEW WORK
ELEVATIONS AND SECTIONS
11. SEE DRAWING SERIES A8.00 FOR NEW WORK DETAILS
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:0
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
PROPOSED PLAN - PHASE 2 - LEVEL 2
Project Number
DSS
VGD
08/18/14
VGD
A2.2.02 15 35
1/8" = 1'-0"A2.2.02
PROPOSED PLAN - PHASE 2 - LEVEL 21
167 EXISTING STUCCO FACED COLUMN TO REMAIN
205 NEW VERTICAL CONCEALED FASTENER METAL
PANELS ATTACHED TO 3/4" METAL GIRTS OVER 5/8"
EXTERIOR SHEATHING AND ADDITIONAL NEW
METAL FURRING ON EXISTING METAL FRAMING.
PROVIDE BUTYL TAPE BETWEEN DISSIMILAR
METAL COMPONENTS. PROVIDE ADDITIONAL
METAL FURRING ON EXTERIOR SIDE OF
SCREENWALL TO ENSURE FINAL METAL PANEL
FINISH ALIGNS WITH PHASE 1 METAL PANEL FINISH
218 NEW METAL WALL PANEL TRIM, FINISH TO MATCH
NEW METAL WALL PANELS. SEE ALSO ELEVATIONS
AND DETAILS
IE
A3.2.02
A3.2.02
A3.2.02
A3.2.00
A3.2.00
A3.2.00
A8.0.00
SIM
A8.0.00
SIM
A8.0.01
TYP
154 TYP
A8.0.01
TYP
SIM SIM
TYP
A8.0.01
SIM
GENERAL NOTES
SHEET KEYNOTES
REFERENCE LEGEND
1. FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ARCHITECT IF FIELD CONDITIONS RESULTING FROM
EXPOSED DEMO WORK
2. REMOVE AND REATTACH EXISTING FIXTURES ATTACHED
TO WALL AS REQUIRED FOR DEMOLITION AND NEW
WORK; INCLUDING BUT NOT LIMITED TO ACCESS
KEYPAD, LIGHTS, ALARMS, SIGNS, AND CONDUIT
3. RESEAL ALL PENETRATIONS OR OPENINGS THROUGH
WALLS OR SOFFITS TO MAINTAIN WEATHERTIGHT
NATURE OF ENCLOSURE
4. DETAILS FOR VERTICAL ORIENTATION METAL PANELS
ARE TYPICAL IN NATURE AND ARE TO ENSURE
WEATHERTIGHTNESS, PLEASE ALSO REFER TO METAL
PANEL MANUFACTURER'S SPECIFIC INSTRUCTIONS AND
DETAILS
5. METAL PANEL INSTALLER SHALL ENGINEER
COMPATIBLE FASTENER AND GIRT BASED ON EXISTING
CONDITIONS AND SELECTED METAL PANEL
MANUFACTURER
6. SEE DRAWING SERIES A1.0.00 FOR EXTENT OF DEMO
WORK
7. SEE DRAWING A2.0.00 FOR OVERALL PHASING OF NEW
WORK
8. SEE DRAWING A2.0.00 FOR EXTERIOR FINISH
SCHEDULE
9. SEE DRAWING SERIES A2.0.00 FOR NEW WORK
10. SEE DRAWING SERIES A3.0.00 FOR NEW WORK
ELEVATIONS AND SECTIONS
11. SEE DRAWING SERIES A8.00 FOR NEW WORK DETAILS
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:0
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
PROPOSED PLAN - PHASE 2 - LEVEL 3
Project Number
DSS
VGD
08/18/14
VGD
A2.2.03 16 35
1/8" = 1'-0"A2.2.03
PROPOSED PLAN - PHASE 2 - LEVEL 31
154 EXISTING STRUCTURE SUPPORT WRAPPED IN
METAL PANELS TO REMAIN. REFINISH TO MATCH
ADJACENT METAL PANEL REFINISHING PT-1 IN
PHASE 1 NEW WORK. SEE ALSO DETAIL 2/A8.0.01
FOR TYPICAL METAL PANEL PENETRATION
205 NEW VERTICAL CONCEALED FASTENER METAL
PANELS ATTACHED TO 3/4" METAL GIRTS OVER 5/8"
EXTERIOR SHEATHING AND ADDITIONAL NEW
METAL FURRING ON EXISTING METAL FRAMING.
PROVIDE BUTYL TAPE BETWEEN DISSIMILAR
METAL COMPONENTS. PROVIDE ADDITIONAL
METAL FURRING ON EXTERIOR SIDE OF
SCREENWALL TO ENSURE FINAL METAL PANEL
FINISH ALIGNS WITH PHASE 1 METAL PANEL
FINISH
218 NEW METAL WALL PANEL TRIM, FINISH TO MATCH
NEW METAL WALL PANELS. SEE ALSO
ELEVATIONS AND DETAILS
SHEET KEYNOTES
REFERENCE LEGEND
1. FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ARCHITECT IF FIELD CONDITIONS RESULTING FROM
EXPOSED DEMO WORK
2. REMOVE AND REATTACH EXISTING FIXTURES ATTACHED
TO WALL AS REQUIRED FOR DEMOLITION AND NEW
WORK; INCLUDING BUT NOT LIMITED TO ACCESS
KEYPAD, LIGHTS, ALARMS, SIGNS, AND CONDUIT
3. RESEAL ALL PENETRATIONS OR OPENINGS THROUGH
WALLS OR SOFFITS TO MAINTAIN WEATHERTIGHT
NATURE OF ENCLOSURE
4. DETAILS FOR VERTICAL ORIENTATION METAL PANELS
ARE TYPICAL IN NATURE AND ARE TO ENSURE
WEATHERTIGHTNESS, PLEASE ALSO REFER TO METAL
PANEL MANUFACTURER'S SPECIFIC INSTRUCTIONS AND
DETAILS
5. METAL PANEL INSTALLER SHALL ENGINEER
COMPATIBLE FASTENER AND GIRT BASED ON EXISTING
CONDITIONS AND SELECTED METAL PANEL
MANUFACTURER
6. SEE DRAWING SERIES A1.0.00 FOR EXTENT OF DEMO
WORK
7. SEE DRAWING A2.0.00 FOR OVERALL PHASING OF NEW
WORK
8. SEE DRAWING A2.0.00 FOR EXTERIOR FINISH
SCHEDULE
9. SEE DRAWING SERIES A2.0.00 FOR NEW WORK
10. SEE DRAWING SERIES A3.0.00 FOR NEW WORK
ELEVATIONS AND SECTIONS
11. SEE DRAWING SERIES A8.00 FOR NEW WORK DETAILS
A B C D F G H
IE
A3.3.02
A3.3.02
A3.3.02
A3.3.00
A3.3.00
A3.3.00
A8.0.00
TYP
A8.0.00
TYP
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EXISTING METAL PANELS TO
BE REFINISHED (PHASE 1)
NEW METAL PANELS OVER
RIGID INSULATION/SHEATHING
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
Revisions
GMG
EPMProject Manager
A-E Firm USDA
PPMDesigner
Safety & HealthChecked by
Real Property
Project No.
Date
USDA Contracting Office 2150 Centre Avenue Building D, Suite 310 Fort Collins, CO 80526
Agricultural Research Service
DescriptionByDateNo.
Sheet No.
U S D A---
--- OF
/1
/2
:4
:0
P M
GRAND FORKS HUMAN NUTRITION
RESEARCH LABORATORY PARTIAL
EXTERIOR FACADE RENOVATION
PROPOSED PLAN - PHASE 3 - LEVEL 2
Project Number
DSS
VGD
08/18/14
VGD
A2.3.02 17 35
201 NEW VERTICAL CONCEALED FASTENER METAL
PANELS ATTACHED TO RAINSCREEN SYSTEM OF
3/4" METAL GIRTS OVER 2.5" POLY ISO RIGID
INSULATION SHEATHING WITH INTEGRAL
AIR/WEATHER BARRIER
1/8" = 1'-0"A2.3.02
PROPOSED PLAN - PHASE 3 - LEVEL 21
SHEET KEYNOTES
REFERENCE LEGEND
1. FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ARCHITECT IF FIELD CONDITIONS RESULTING FROM
EXPOSED DEMO WORK
2. REMOVE AND REATTACH EXISTING FIXTURES ATTACHED
TO WALL AS REQUIRED FOR DEMOLITION AND NEW
WORK; INCLUDING BUT NOT LIMITED TO ACCESS
KEYPAD, LIGHTS, ALARMS, SIGNS, AND CONDUIT
3. RESEAL ALL PENETRATIONS OR OPENINGS THROUGH
WALLS OR SOFFITS TO MAINTAIN WEATHERTIGHT
NATURE OF ENCLOSURE
4. DETAILS FOR VERTICAL ORIENTATION METAL PANELS
ARE TYPICAL IN NATURE AND ARE TO ENSURE
WEATHERTIGHTNESS, PLEASE ALSO REFER TO METAL
PANEL MANUFACTURER'S SPECIFIC INSTRUCTIONS AND
DETAILS
5. METAL PANEL INSTALLER SHALL ENGINEER
COMPATIBLE FASTENER AND GIRT BASED ON EXISTING
CONDITIONS AND SELECTED METAL PANEL
MANUFACTURER
6. SEE DRAWING SERIES A1.0.00 FOR EXTENT OF DEMO
WORK
7. SEE DRAWING A2.0.00 FOR OVERALL PHASING OF NEW
WORK
8. SEE DRAWING A2.0.00 FOR EXTERIOR FINISH
SCHEDULE
9. SEE DRAWING SERIES A2.0.00 FOR NEW WORK
10. SEE DRAWING SERIES A3.0.00 FOR NEW WORK
ELEVATIONS AND SECTIONS
11. SEE DRAWING SERIES A8.00 FOR NEW WORK DETAILS
A B C D F G H
IE
A3.3.02
A3.3.02
A3.3.02
A3.3.00
A3.3.00
A3.3.00
201 201 207201
A8.0.00
TYP
A8.0.00
SIM
A8.0.00
TYP
A8.0.00
SIM
A8.0.00
TYP
A8.0.00
SIM
A8.0.00
TYP
A8.0.01
SIM
A8.0.01
SIM
SIM
TYP
TYP
PLAN AND SECTION WALL LEGEND
EXISTING WALL TO REMAIN
DEMO EXISTING BRICK VENEER AND
RIGID INSULATION/SHEATHING AND
BLANKET INSULATION WHERE OCCURS
EX…
This is the start of the file's text. The full file is on GovTribe.