Copyright 2001 AIA MASTERSPEC SMALL PROJECT™ 2001

WOOD SHINGLES AND SHAKES 07317 - 1

SECTION 07317 - WOOD SHINGLES AND SHAKES

PART 1 - GENERAL

1.1 SECTION REQUIREMENTS

A. Submittals: Product Data and Samples.

B. Fire-Test-Exposure Classification: UL 790, ASTM E 108, Class C. Where specified.

PART 2 - PRODUCTS

2.1 SHINGLES, SHAKES, AND PANELS

A. Grading Standard for Wood Shingles: CSSB's "Grading Rules for Certigrade Red Cedar Shingles."

B. Cedar Shingles: No.1 grade, Blue Label, smooth sawn, 16 inches long; 5 shingles, 2 inches thick at butt, un-treated.

2.2 ACCESSORIES

A. Felt Underlayment: ASTM D 226, Type II, No. 30.

B. Self-Adhering Sheet Underlayment: ASTM D 1970, SBS-modified asphalt; mineral-granule or slip-resisting-polyethylene surfaced; with release paper backing; cold applied.

C. Nails: Hot-dip galvanized or stainless-steel nails of sufficient length to penetrate 3/4 inch (19 mm) into solid wood decking or extend at least 1/8 inch (3 mm) through OSB or plywood sheathing.

1. Use shingle-type nails to attach wood shingles.

2. Use box-type nails to attach wood shakes.

D. Sheet Metal flashing and Trim: Comply with requirements in Division 7 Section "Sheet Metal Flashing and Trim."

1. Sheet Metal: Zinc-tin alloy-coated stainless steel, Zinc-coated (galvanized) steel.

2. Fabricate sheet metal flashing and trim to comply with recommendations in SMACNA's

"Architectural Sheet Metal Manual."

PART 3 - EXECUTION

3.1 INSTALLATION

A. Comply with CSSB's "Design and Application Manual for New Roof Construction"; and NRCA's "The

NRCA Roofing and Waterproofing Manual": Section "The NRCA Steep Roofing Manual," Chapter

"Wood Shingle and Wood Shake Roofing" for roofing installations.

Copyright 2001 AIA MASTERSPEC SMALL PROJECT™ 2001

WOOD SHINGLES AND SHAKES 07317 - 2

B. Apply self-adhering sheet underlayment along entire perimeter of roof sheathing; extend a minimum of

36 inches inside exterior wall line at edges. Apply 36” out from sidewall, valley and chimney flashings.

C. Comply with CSSB's "Design and Application Manual for Exterior and Interior Walls" for wall installations.

END OF SECTION 07317