AG-024B-S-17-9009_Attach_03-Equipment_02-07-2017.pdf

PDF 153 KB Posted

Attached to
National Long-Term Fire Retardant - Bulk Federal contract opportunity
Solicitation number
AG-024B-S-17-9009
Issued by
Department of Agriculture Forest Service Fire and Aviation Management National Interagency Fire Center

About this file

Equipment

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation No. AG-024B-S-17-9009 US Forest Service National Long-Term Fire Retardant - Bulk National Office

Exhibit J-1: Facility, Government and Contractor Equipment

J1 - 1

AGENCY CLIN NO. &

BASE

AGENCY

OWNED

HANDLING

EQUIPMENT

AGENCY

OWNED

MIXING

EQUIP.

AGENC

OWNED

STORAGE

TANKS

OTHER AGENCY

OWNED SUPPLIES

OTHER REQUIREMENT OF

CONTRACTOR

COMMENTS DAILY

PEAK

DEMAND

(gallons)

FS/R1 CLIN 01

Missoula, MT

3 Forklifts 1 Eductor and 1 Centrifugal

Pump.

3 Retardant storage tanks

- 21,000 gals.

total

Hoses, valves, manifold, pumps.

One transfer pump furnished by contractor, Mixing tank

2-Agency owned micro motion meters, Batch Control System

100,000

FS/R1 CLIN 02

West

Yellowstone, MT

3 Forklifts Batch mixer 1-10,000 gal retardant

29,000 total gal water storage tanks

Hoses, valves, manifold, pumps. 1

Agency owned micro-motion meter

3,000 sq.ft. covered storage 50,000

FS/R1 CLIN 03

Coeur d’ Alene, ID

1-Forklift (good condition but old).

1 Centrifugal Pump

2-10,000 gal retardant tanks; 1-

10,000 gal water tank

2 – F model Micro Motion Meters, hoses, valves, check valve, manifold, 1 recirculation and shipment offload pump.

Blending Valve system with bypass and check valve

Need reconstruction of evaporation pond with diversion valve for storm water runoff, tank containment, taxiway is narrow, loading pits need reconfigured, pilot area too small during heavy activity (design pending)

50,000

FS/R1 CLIN 04

Grangeville, ID

1-Forklift 1- 14A Pump 1 new (2010) micro-motion used for mixing

1-9,000 gal retardant tank

1-9,000 gal water tank

1-micro motion (used for loading), 1 pressure pump with hose reel, load hoses, valves and skates, 1 gas homelite pump

1 200 gpm pump with control panel, 1 14A pump, 1 Canadian blender, hoses and fittings, 1 6000 gal retardant tank

Need to construct an approved containment/evaporation system

50,000

FS/R2 CLIN 05

Jeffco, CO

(Metro- Denver)

1-Forklift Yes – Y Blender

3-12,000 gal retardant tanks; 1-

10,000 gal water tank

3 Agency owned micro- motion meters;

Hoses, valves, manifold, pumps.

30,000

BLM CLIN 06

Roswell, NM

None Yes – Y Blender

1-20,000 gal retardant tank;

1- 30,000 gal water tank; 1-

15,000 gal disposal tank

1 Agency owned micro- motion meter;

Hoses, valves, manifold, pumps.

50,000

FS/R3 CLIN 07

Silver City, NM

1 Forklift None 4-10,000 gal tanks 2-

20,000 gal water tanks

Hoses, valves, manifold, pumps. 1

Agency owned micro-motion meter

Water & air pumps & 66,000 gal water tank on 24' diameter concrete pad furnished by contractor

Covered storage available 83,000

FS/R3 CLIN 08

Alamogordo, NM

2 Forklifts Eductor 2-12,000 gal tanks; 1-

12,000 gal water; 1-4,000 gal offload.

12,000 gal tanks w/ man-holes top/end.

2 Agency owned micro- motion meters

Hoses, valves, manifold, pumps.

5 Fairly new pumps, 2 gas and 3 electric

83,000

J1 - 2

BASE

AGENCY

OWNED

HANDLING

EQUIPMENT

AGENCY

OWNED

MIXING

EQUIP.

AGENC

OWNED

STORAGE

TANKS

OTHER AGENCY

OWNED SUPPLIES

OTHER REQUIREMENT OF

CONTRACTOR

COMMENTS DAILY

PEAK

DEMAND

(gallons)

BIA CLIN 09

White River, AZ

All Agency provided

All Agency provided

1-5,000 gal water tank; 1-

4,000 gal retardant tank

Hoses, valves, manifold, pumps

SEAT Base only,Contractor to provide pump to recirculate and fill SEAT, contractor mixing trailer

Serves as a Reload Base when multiple fires are in the area. Show

Low is the main base.

30,000

FS/R5 CLIN 10

Bishop, CA

1 Forklift Eductor 1-25,000 gal water tank; 1-

6,000 gal retardant tank;

1-10,000 gal retardant tank

1 Agency owned micro- motion meter;

Hoses, valves, manifold, pumps.

Truck filled underground water storage.

75,000

FS/R5 CLIN 11

Porterville, CA

2 Forklifts Eductor 1-40,000 gal water tank; 1- 37,500 gal mix tank; 1-37,500 gal holding tank

Silo Storage (112,000 lbs) Hoses, valves, manifold, pumps.

Offload capability 4 Agency owned micro motion meters 250,000

FS/R5 CLIN 12

Montague, CA

None 1 Centrifugal pump

1-20,000 gal water; 2-

10,000 gal retardant; 1-

8,000 gal offload tank.

Hoses, valves, manifold, pumps

1 Agency owned micro motion meter 100,000

BIA CLIN 13

Omak, WA

None

1-3,000 gal.

retardant; 1-

1200 gal.

Hoses, valves, manifold, pumps

30,000

FS/R6 CLIN 14

La Grande, OR

None Centrifugal Blender

1-10,000 gal water; 2-

10,000 gal retardant; 1-

5,000 gal retardant; 1-

5,000 gal offload; 1- 12,000 gal water; 2-

12,000 gal retardant

Hoses, valves, manifold, 4-pumps

No powder storage 1 Agency owned MicroMotion meter 160,000

FS/R6 CLIN 15

Troutdale, OR

3,500 lb Forklift Orfice Blender 1-10,000 gal water; 2-5,000 gal retardant;

1-10,000 gal retardant; 1-

5,000 gal offload

1 Agency owned MicroMotion meter

Hoses, valves, manifold, pumps

3,500 lb Forklift Requires 2 hr. notice to be fully operational

12,500

J1 - 3

BASE

AGENCY

OWNED

HANDLING

EQUIPMENT

AGENCY

OWNED

MIXING

EQUIP.

AGENC

OWNED

STORAGE

TANKS

OTHER AGENCY

OWNED SUPPLIES

OTHER REQUIREMENT OF

CONTRACTOR

COMMENTS DAILY

PEAK

DEMAND

(gallons)

FS/R6 CLIN 16

John Day, OR

None Orfice Blender, 1

Agency owned

MicroMotion meter

1-6,000 gal water tank; 2-

6,000 gal retardant tanks

Hoses, valves, manifold, pumps

Recirc and load pumps are both new

5,340

FS/R8 CLIN 17

Fayetteville, AR

1 Forklift None 4-10,000 gal tanks; 3-gas powered pumps

Eductor, pump, and mass-flow meter belong to contractor.

10,000

FS/R8 CLIN 18

Chattanooga

, TN

1 Forklifit 1 electric mixing Pump

4 -10,000 gal tanks.

3 Micro-Motion Meters; Hoses, valves, manifold; 1 electric loading pump, 1 gas-powered loading pump.

Eductor is contractor owned, 2 aeration pumps, 4-cylinder

Wisconsin pump.

3-in. portable pump is property of current contractor

40,000

FS/R8 CLIN 19

Lake City, FL

1 Forklift 1 centrifugal pump, Eductor

4 -10,000 ga tanks.

4 - Pumps, each 400

– 500 gal/min, Loading Valves, Micro Motion Meter, Electric

Pumps.

Operations building and warehouse storage are present.

10,000 sq.ft. of surfaced, unpaved, uncovered storage available.

30,000

BLM CLIN 20

Ft.

Wainwright, AK

1 Forklift 1 Orifice blender and 1

Centrifugal Pump.

2 – 12,500 retardant tanks, 1-

10,000 gal water tank.

2 Agency-owned micro motion meters.

Hoses, valves, manifold, pumps.

31,033

BLM CLIN 21

Canon City, CO

None 1-Mix Tank None 2-Wacker 4" Pumps, Water supply hose, Backflow preventer

Currently P100 - convert to LC95A-F (when LC fugitive product has accept. colorant) One (1)-12,000 gallon

Retardant Tank

Existing Powder System Rented from

ICL

25,000

BLM CLIN 22

Cortez, CO

None 1-Mix Tank None 2-Wacker 4" Pumps, Water supply hose, Backflow preventer

Currently P100 – convert to LC- 95A-F (when LC fugitive product has acceptable colorant)

Existing Powder System Rented from

ICL

25,000

BLM CLIN 23

Rifle, CO

None 1-Mix Tank None 2-Wacker 4" Pumps, Water supply hose, Backflow preventer

Currently P100 – convert to LC- 95A-F (when LC fugitive product has acceptable colorant) One (1)-8,000 gallon Retardant Tank

Existing Powder System Rented from

ICL

25,000

J1 - 4

BASE

AGENCY

OWNED

HANDLING

EQUIPMENT

AGENCY

OWNED

MIXING

EQUIP.

AGENC

OWNED

STORAGE

TANKS

OTHER AGENCY

OWNED SUPPLIES

OTHER REQUIREMENT OF

CONTRACTOR

COMMENTS DAILY

PEAK

DEMAND

(gallons)

BLM CLIN 24

Craig, CO

None None None LC 95A-R & LC 95A-F 25,000

BLM CLIN 25

Kremmling, CO

None 1-Mix Tank None 2-Wacker 4" Pumps, Water supply hose, Backflow preventer

LC-95A-R until acceptable colorant in LC-95A-F

System set-up for LC product 25,000

BLM CLIN 26

Rawlings, WY

None None None Backflow preventer, Water supply hose

Secondary containment berm, LC-95A-R

System set up for LC product 25,000

BLM CLIN 27

Casper, WY

None None None Backflow preventer, Water supply hose

LC-95A-R System set up for LC product 25,000

BLM CLIN 28

Greybull, WY

None None None Backflow preventer, Water supply hose

LC-95A-R New base – no existing infrastructure at present.

25,000

BLM CLIN 29

Ontario, OR

None None

1 – 2,400 gal off-load tank (if needed)

One steel mix tank (1,600- 2,000 gal capacity), plumbed w/3" fittings, hose, recirc system, secondary containment, (Note: no pump)

Water supplied via hydrant to site, spill drainage into airport system 29 May 15 added – misc fittings

25,000

BLM CLIN 30

Burns, OR

None 1 - 800 Poly water tank

1 - 10,000 & 1

- 5,000 gal.

water tank. 1 poly off-load tank

Misc 3" hose & fittings, 1 pump

(water) and 2 LC back-up pumps

One steel mix tank (1,600- 2,000 gal capacity), plumbed w/3" fittings, hose, recirc system, secondary containment, loading pump

Secondary containment system in place (designed 2-5,000 gal tanks).

29 May 15 added - 1 LC Blender fitted with check valves, cam locks, adj. steel frame; 2 20HP 14A2-B

Pumps and misc fittings

25,000l

BLM CLIN 31

Lakeview, OR

1 - 10,000 gal.

water tank, 1 poly off-load tank (if needed)

3" hose for water supply & 3" hose for mixing/ truck off-loading of retardant

One steel or poly mix tank (1,600-2,000 gal capacity), plumbed w/3" fittings, hose, recirc system, secondary containment, loading pump

Secondary containment system in place Retardant tank & pumps in place owned by ICL

25,000

BLM CLIN 32

Safford, AZ

None 1,000 gal mix tank, two 11.0 Horsepower

GX 390

Honda pumps.

3" hoses, fittings, etc. to mix/load from

2 pumps.

One 16,000 gal steel water tank, two 5,000 gal steel LC retardant tanks

2 industrial Seepex pumps used to recirulate retardant;

complete set of hoses, fittings, etc. needed to recirculate & load/off-load retardant; small air compresser & spray washer

LC-95A. Replace interior recirc system in both 5,000 gal (vertical) retardant tanks;

current system is ineffective at keeping retardant recirculated.

Note: interior condition of tank walls in very good shape & do not need to be re-finished at this time.

10,000

BLM CLIN 33

Tooele, UT

3 poly water tanks (various sizes)

Honda trash pump for pumping septic

LC-95A, 2 loading pumps, 1 truck off-loading pump & hose, and all required hoses for pumping retardantand water.

LC tank cleaned prior to 2013 season. One 8,000 gal steel LC tank owned by ICL

J1 - 5

BASE

AGENCY

OWNED

HANDLING

EQUIPMENT

AGENCY

OWNED

MIXING

EQUIP.

AGENC

OWNED

STORAGE

TANKS

OTHER AGENCY

OWNED SUPPLIES

OTHER REQUIREMENT OF

CONTRACTOR

COMMENTS DAILY

PEAK

DEMAND

(gallons)

BLM CLIN 34

Nephi, UT

LC-95A, 2 loading pumps, 1 truck off-loading pump & hose, mix tank (1,600-2,000 gal capacity), one 6,000 gal retardant tank & one 6,000 gal water tank. Recirc systems & secondarycontainment for retardant & mix tanks. All required hoses for pumping retardant & water.

Water is trucked in. 25,000

BLM CLIN 35

Fillmore, UTV

LC-95A, 2 loading pumps, 1 truck off-loading pump & hose, mix tank (1,600-2,000 gal capacity), one 6,000 gal retardant tank & one 6,000 gal water tank. Recirc systems & secondarycontainment for retardant & mix tanks. All required hoses for pumping retardant & water.

Water on-site 25,000

BLM CLIN 36

McDermitt, NV

1 - 1,000 gal poly retardant tank.

2 loading pumps, retardant tank (8K), loading hoses & skates, secondary containment.

Provide wheeled loading hose nozzle/spillprevention bucket.

LC-95A

Water from hydrant onsite. 5,000

BLM CLIN 37

Wells, NV

1 - 4,000 Poly water tank.

800' of 2.5" hose to fill water tank, backflow preventor for water hydrant. One 11 HP

Honda WT30X Trash Pump.

LC-95A, 2 loading pumps, 1 truck off-loading pump & hose.

Recirc system* for retardant tank. Secondary containment adequate for tank size. All required hoses for pumping retardant and water. Provide wheeled loading hose nozzle/spill prevention bucket.

6000 gal retardant tank.

Water on-site. Hydrant on-site; need hose from hydrant to tank.

Current 6,000 gallon tank has met all daily peak demands.

BLM CLIN 38

Panaca, NV

1 - 6,000 gallon water tank.

600' of 1.5" hose Hydrant to tank, various camlock-

Banjo fittings

LC-95A. 2 pumps, 6,000 gal LC tank w/recirc system*, 3" loading hose and adequate secondary containment. All required hoses for pumping retardant and water. Provide wheeled loading hose nozzle/spill prevention bucket.

Hydrant onsite approx 500 feet from SEAT base.

J1 - 6

BASE

AGENCY

OWNED

HANDLING

EQUIPMENT

AGENCY

OWNED

MIXING

EQUIP.

AGENC

OWNED

STORAGE

TANKS

OTHER AGENCY

OWNED SUPPLIES

OTHER REQUIREMENT OF

CONTRACTOR

COMMENTS DAILY

PEAK

DEMAND

(gallons)

BLM CLIN 39

Jean, NV

None None 500' of 2.5" hose Hydrant to LC tank, various hose fittings

LC-95A. 2 pumps, one 5,000 gal tank w/recirc system*, 3" loading hose and secondary containment. All required hoses for pumping retardant and water. Provide wheeled loading hose nozzle/spill bucket.

hydrant on site approx 500 feet from SEAT ops.

25,000

BLM CLIN 40

Mesquite, NV

None None 2 - 6,000 gallon water tank.

One Wacker pump.

100' of 2.5" hose

(hydrant to LC tank), various hose & fittings.

LC-95A. 1 pump, two 6,000 gal LC tanks w/recirc systems, 3" loading hose, with OSHA compliant ladder with platform.

Provide wheeled loading hose nozzle/spill prevention bucket.

Provide adequate secondary containment.

Hydrant on site approx 100 feet from SEAT base.

25,000

BLM CLIN 41

Mountain Home, ID

None Four Tsurumi trash pumps

(11.0 HP

Hond motors).

20 varying lengths of 3' suction & corrugated hoses, two

100' lengths of rubber-jack.

hose, fittings, valves, tees, etc. needed to mix and load aircraft from two pumps.

Two 6,000 gallon and one 1,500 vertical poly water tanks, two 5000 gallon vertical poly retardant tanks.

(see mixing equipment)

Two loading pumps (Wackers or equivalent)

40,000 Note: the two 5,000 gal poly tanks have met the need over the previous ten years.

FS/R2 CLIN 42

Pueblo, CO unknown unknown unknown unknown unknown unknown unknown

File details come from the government source that posted it. Updated .