Inspection Date JUNE 11,2012
Company Name SimplexGrinnell
Address Address
City State & Zip City, State & Zip
Owner Contact
Building
Transmission Type
Last Service Date
December 14th 2007
Quantity Circuit Style
21 B
10 B
High Pressure Switch
Alarm Verification feature is
Ionazation Smoke Detector
Comments
Photoelectric Smoke Detector
Software Revision
Annual Inspection Simplex 4002
Service Type
Waterflow Switch
ALARM INITIATING DEVICES AND CIRCUIT INFORMATION
Building Occupants AHJ Notified of pre-existing Impairments
# Of CircuitsInitiating Circuit Style # Of Circuits Notification Circuit Style
NOTIFICATIONS MADE PRIOR TO ANY TESTING
DATE & TIME
Secuirty Office
7:00AM
WILLIE SAMPSON/JEFF SPICKNALL
22712 COMMERCE CTR CT #114
DULLES, VA 20166
Office Phone
Office License # 564
TROY
Central Station Operator January 15th 2009 12:45pm
Stanely Chapel
703-996-0782
Monitoring Entity
Central Station Phone Number
Monitoring System Account Number
Secuirty Office
See Sprinkler Report
NAMEENTITY NOTIFIED
Building Management
Duct Detector
Heat Detector
Device Type
Fire Pump Run
See Sprinkler Report
Multi-Sensor
Armed Forces Retirement Home
Kitchen Hood System
Optical Detector
Manual Pull Station
Beam Detector
Telephone Date of Last Software
Revision Manufacturer MODEL
FIRE ALARM SYSTEM
NFPA 72 REPORT OF INSPECTION and TEST (Page 1 of 4)
202-730-3111
Inspection Time
3700 North Capitol St. NW
Inspection Report Number
Washington, DC 20011
Inspection Contract Number
Approving Agency
Contact
WILLIE SAMPSON 129164
Chemical Fire Suppression System
Inspection Technician SignatureLicense Number
Owner: Jack Kleminich Author: Eugene Turek Last Revised: 11/13/2003
Company Name
Quantity Circuit Style
4 B
9 B
Quantity Circuit Style
Quantity
120 VAC 20
BREAKER 20
VISUAL
YES
N/A
YES
YES
YES
YES
YES
YES
N/A
YES
VISUAL
YES
Specific Gravity N/A
Transient Suppressors
Charger Test YES Discharge Test YES
SYSTEM TESTS AND INSPECTIONS SECONDARY POWER
Trouble Signals Disconnect Switches
Remote Annunciators
PRIMARY SYSTEM POWER SUPPLIES SECONDARY (STANDBY) POWER SUPPLY
Fire Pump Loss of Phase
Generator Run Indicator
Bell
AND STYLE OF SIGNALING LINE CIRCUITS CONNECTED TO THIS SYSTEM
Water Tank Level
PIV Tamper
Horn
Speaker
Chime
ALARM NOTIFICATION APPLIANCES AND CIRCUIT INFORMATION
Are circuits monitored for electrical integrity?
Device Type
YES
Comments
Horn / Strobe
Speaker / Strobe
Chime / Strobe
If the answer is "YES" what type & article as defined in NFPA 70
Fire Pump Trouble
Over current Protection Type Amps Calculated capacity to operate the system, in hours
Amps Battery Type 12 Volt
Location of Supply Panel board Basement Type of engine-driven generator dedicated to alarm system
Is an Emergency or Standby system used as a backup to primary power supply, instead of using a secondary power supply
Amp Hr RatingPrimary Main Nominal Voltage
Low Pressure Switch
Fuses YESPrimary Power Supply
Battery Condition
Ground - Fault Monitoring N/A
FUNCTIONALTYPE
Inspection Date JUNE, 11,2012
Main Panel (1) 13.23 volts 5.61 AH (2) 13.34 volts 4.67 AH
Location of Fuel Storage
FIRE ALARM SYSTEM
NFPA 72 REPORT OF INSPECTION and TEST (Page 2 of 4)
Armed Forces Retirement Home
Load Voltage YES
YES
YES
Disconnecting means location
Inspection Report Number Inspection Contract Number
SUPERVISORY SIGNAL INITIATING DEVICES AND CIRCUIT INFORMATION
Device Type Comments, Incidents, or Deficiency Notes
OS & Y Tamper See Sprinkler Report
Plug Tamper
SYSTEM TESTS AND INSPECTIONS CONTROL PANELS
TYPE FUNCTIONAL COMMENTS
Control Unit Interface Equipment Lamps & LED's
Strobe
COMMENTS
YES
YES
N/A
YES
YES
VISUAL
YES
YES
N/A
VISUAL
N/A N/A N/A N/A N/A N/A
VISUAL
N/A N/A N/A N/A N/A N/A N/A N/A N/A
VISUAL
N/A N/A N/A N/A N/A N/A
RESULT
YES
YES
YES
YES
# YES
N/A
Kitchen Hood System
TYPE TIME COMMENTS
Alarm Signal
Pre-Action System N/A
CENTRAL STATION SIGNAL VERIFICATION
AFFF Foam System
Dry Chemical System N/A Deluge System N/A
N/A Alarm Restoration
TYPE FUNCTIONAL COMMENTS
SYSTEM TESTS AND INSPECTIONS SPECIAL HAZARD SYSTEMS
N/A
Supervisory Signal N/A
Fire Damper Control N/A
Gas Suppression System N/A
Emergency Power Shunt Trip N/A
Tone Generator (s) N/A
Did not perform annual elevator inspection.
Elevator Shunt Trip
Exhaust Fan Shut Down
Amplifier (s) N/A
Off - Hook Indicator N/A
TYPE FUNCTIONAL COMMENTS
Voice Clarity N/A
SYSTEM TESTS AND INSPECTIONS EMERGENCY COMMUNICATIONS EQUIPMENT
N/APhone Set
TYPE FUNCTIONAL
Speakers N/A
YES
Visible YES
SYSTEM TESTS AND INSPECTIONS NOTIFICATION APPLIANCES
TYPE FUNCTIONAL COMMENTS
Audible
Inspection Date Jun-12
FIRE ALARM SYSTEM
NFPA 72 REPORT OF INSPECTION and TEST (Page 3 of 4)
Armed Forces Retirement Home
Inspection Report Number Inspection Contract Number
SYSTEM TESTS AND INSPECTIONS INTERFACE EQUIPMENT
Elevator Recall
Door Release to Close N/A Door Unlock N/A
N/A
Supervisory Restoration N/A
Smoke Control System N/A HVAC Shut Down N/A
N/A
Trouble Signals N/A N/A
N/A
COMMENTS
N/ACall - in Signal
Phone Jacks N/A
Date
System Restored to Normal Operation? NO Date Time
Building Occupants
Central Station Operator Secuirty Office
Building Management
Supervising Technician License Number
NOTIFICATIONS THAT TESTING IS COMPLETE
ENTITY NOTIFIED
FIRE ALARM SYSTEM
NFPA 72 REPORT OF INSPECTION and TEST (Page 4 of 4)
Armed Forces Retirement Home
NAME DATE & TIME
Inspection Date JUNE 11,2012
Inspection Report Number Inspection Contract Number
This Fire Alarm System was left with the Annuciator Trouble.
THIS IS TO CERTIFY THAT THE FIRE ALARM SYSTEM HAS BEEN TESTED AND INSPECTED IN ACCORDANCE WITH THE APPLICABLE NFPA STANDARDS
SYSTEM WIDE INCIDENT, COMMENTS, AND DEFICIENCY SECTION
FIRE ALARM SYSTEM DEVICE RECORD
Armed Forces Retirement Home
Inspection Report Number
Location Are a or Fl oo r
Dev ice
De sc rip tio n Ta sk Fr eq ue nc y
Dev ice
Ad dr es s or
Circ ui t N um be r
Ala rm
O pe ra tio n Ve rif ie d
Ann un ci at or In di ca tio n
Rem ot e In di ca tio n
La m p
Su pe rv is io n of Dev ic e
Dev ic e Cle an ed th is in sp ec tio n
Se ns iti vi ty Se tti ng
(0
4) or
Fl ow
Sw itc h De la y
Ti m er
Comments
At Chapel Entrance (1) 1st Floor Smoke Detector Annual
At Chapel Entrance (2) 1st Floor Smoke Detector Annual Chapel (1) 1st Floor Pull Station Annual X X X P Chapel (2) 1st Floor Pull Station Annual X X X P Chapel (3) 1st Floor Pull Station Annual X X X P Chapel Exit (1) 1st Floor Pull Station Annual X X X P Chapel Exit (2) 1st Floor Pull Station Annual X X X P Chaplain's Office 1st Floor Smoke Detector Annual X X X X X P Elevator Lobby 1st Floor Smoke Detector Annual X X X X X P Main Entrance 1st Floor Pull Station Annual X X X P Balcony (1) 2nd Floor Smoke Detector Annual X X X X X Balcony (2) 2nd Floor Smoke Detector Annual X X X X X Top of Stairs 2nd Floor Pull Station Annual X X X P Corridor Kitchen (Bottom of Ramp) Basement Smoke Detector Annual X X X X X P Mechanical Room Basement Smoke Detector Annual X X X X X P Electrical Room Basement Smoke Detector Annual X X X X X P
NO Access NO Access
Company Name:
Inspection Report Number:
Date:
Page:
Location Are a or Fl oo r
Dev ice
De sc rip tio n Ta sk Fr eq ue nc y
Dev ice
Ad dr es s or
Circ ui t N um be r
Ala rm
O pe ra tio n Ve rif ie d
Ann un ci at or In di ca tio n
Rem ot e In di ca tio n
La m p
Su pe rv is io n of Dev ic e
Dev ic e Cle an ed th is in sp ec tio n
Se ns iti vi ty Se tti ng
(0
4) or
Fl ow
Sw itc h De la y
Ti m er
Comments
Company Name:
Inspection Report Number:
Date:
Page:
Elevator Lobby Basement Smoke Detector Annual X X X X X P Exit by Elevator Basement Pull Station Annual X X X P Hallway by Rooms Basement Pull Station Annual X X X P Kitchen Basement Smoke Detector Annual X X X X X Men's Room Basement Smoke Detector Annual X X X X X Room 1 Basement Smoke Detector Annual X X X X X P Room 3 Basement Smoke Detector Annual X X X X X Room 4 Basement Smoke Detector Annual X X X X X Room 5 Basement Smoke Detector Annual X X X X X Conference Room Basement Smoke Detector Annual P Conference Room Basement Smoke Detector Annual P Conference Room Basement Pull Station Annual P Room 6 Basement Smoke Detector Annual X X X X X Side Exit (Top of Ramp) Basement Smoke Detector Annual X X X X X P Side Exit (Top of Ramp) Basement Pull Station Annual X X X P Corridor By Room 100 Basement Smoke Detector Annual X X X X X P Conference Room Basement Pull Station Annual P Fellowship Hall 1st Floor Smoke Detector Annual X X X X X P Fellowship Hall 1st Floor Smoke Detector Annual X X X X X P Fellowship Hall 1st Floor Smoke Detector Annual
NO Access
NO Access
NO Access NO Access NO Access
NO Access or Fl oo r
Dev ice
De sc rip tio n Ta sk Fr eq ue nc y
Dev ice
Ad dr es s or
Circ ui t N um be r
Ala rm
O pe ra tio n Ve rif ie d
Ann un ci at or In di ca tio n
Rem ot e In di ca tio n
La m p
Su pe rv is io n of Dev ic e
Dev ic e Cle an ed th is in sp ec tio n
Se ns iti vi ty Se tti ng
(0
4) or
Fl ow
Sw itc h De la y
Ti m er
Comments
Company Name:
Inspection Report Number:
or Fl oo r
Dev ice
De sc rip tio n Ta sk Fr eq ue nc y
Dev ice
Ad dr es s or
Circ ui t N um be r
Ala rm
O pe ra tio n Ve rif ie d
Ann un ci at or In di ca tio n
Rem ot e In di ca tio n
La m p
Su pe rv is io n of Dev ic e
Dev ic e Cle an ed th is in sp ec tio n
Se ns iti vi ty Se tti ng
(0
4) or
Fl ow
Sw itc h De la y
Ti m er
Comments
Company Name:
Inspection Report Number:
or Fl oo r
Dev ice
De sc rip tio n Ta sk Fr eq ue nc y
Dev ice
Ad dr es s or
Circ ui t N um be r
Ala rm
O pe ra tio n Ve rif ie d
Ann un ci at or In di ca tio n
Rem ot e In di ca tio n
La m p
Su pe rv is io n of Dev ic e
Dev ic e Cle an ed th is in sp ec tio n
Se ns iti vi ty Se tti ng
(0
4) or
Fl ow
Sw itc h De la y
Ti m er
Comments
Company Name:
Inspection Report Number:
OTHER
SMOKE/FIRE DAMPERS
SMOKE HATCH
EXHAUST FAN
DOOR UNLOCK
SPEAKER
SPEAKER/STROBE
DOOR RELEASE
FAN SHUTDOWN
HORN
HORN/STROBE
VISUAL ONLY (STROBE)
CHIME
CHIME/STROBE
OTHER
OS & Y TAMPER SWITCH
LOW PRESSURE SWITCH
PLUG TYPE TAMPER
WATER LEVEL SWITCH
FIRE PUMP INDICATOR
ANNUNCIATOR
Comments
See Sprinkler Report
See Page 4
9 9 0 0
4 4 0 0
FIRE EXTINGUISHING OR SUPPRESSION SYS SWITCHES
FIRE/GAS & OTHER DETECTORS
FIRE PUMP RUNNING
21 15 0
10 10
SMOKE DETECTORS
HEAT DETECTORS
DUCT DETECTORS
BEAM DETECTORS
MANUAL PULL STATION
ELECTROMECHANICAL RELEASING DEVICE
DEVICE TYPE FIRE
ALARM SUPERVISORY DEVICES
SYSTEM TOTAL
NUMBER TESTED
THIS INSPECTION
NUMBER FAILED
THIS INSPECTION
NUMBER NOT
TESTED THIS
INSPECTION
Comments
FIRE ALARM DEVICE and TEST SUMMARY
Inspection Contract NumberInspection Report Number
Company Name: Armed Forces Retirement Home Inspection Date JUNE, 2012
NUMBER NOT
TESTED THIS
INSPECTION
CommentsDEVICE TYPE FIRE
ALARM INITIATING
SYSTEM TOTAL
NUMBER TESTED
THIS INSPECTION
NUMBER FAILED
THIS INSPECTION
CommentsNUMBER FAILED
THIS INSPECTION
NUMBER FAILED
THIS INSPECTION
NUMBER NOT
TESTED THIS
INSPECTION
NUMBER NOT
TESTED THIS
INSPECTION
DEVICE TYPE FIRE
ALARM NOTIFICATION
SYSTEM TOTAL
DEVICE TYPE FIRE
ALARM AUXILIARY CONTROL
SYSTEM TOTAL
NUMBER TESTED
THIS INSPECTION
1 1
NUMBER TESTED
THIS INSPECTION