This file is a design and specification document for a roof demolition and replacement project prepared for the Office for People with Developmental Disabilities (OPWDD), Finger Lakes Developmental Disabilities Service Office (DDSO), located in Rochester, New York. The project involves the complete removal of the existing asphalt shingle roofing system, including membrane, underlayment, and metal flashing down to the existing roof sheathing at 275 Telephone Road, West Henrietta, New York 14586, a single-family residence. The scope of work includes installation of new Class A laminated asphalt shingles with a minimum 40-year limited warranty, 40-mil polyethylene-faced synthetic underlayment, 40-mil self-adhering ice and water barrier, aluminum drip edge, starter shingles, and metal flashing and trim details. The contractor shall assume approximately 5 percent of the total roof area for water-damaged sheathing replacement, which requires unit pricing and verification by OPWDD. The project document is dated October 23, 2026, as a 90-percent permit set, and no specific bidding deadline, award date, site visit requirements, or contract term is identified within the file itself.
The specifications require the contractor to provide all labor and materials to complete the work in accordance with recognized good standard practices and applicable New York State codes. Materials must be from GAF (G.A.F. Materials Corp) or approved equivalents, selected on a single-source basis to ensure a cohesive warranted system. The contractor shall obtain manufacturer certification confirming approval and authorization to install the specified roofing system to maintain the warranty. The existing building will remain occupied during construction; the contractor must maintain all egress routes, limit disruption and noise, protect the roof 24 hours daily to prevent water leaks, provide temporary services during utility interruptions, and coordinate all work schedules with OPWDD field representatives. Specific requirements include field verification of all existing conditions and dimensions prior to commencement, daily debris removal, compliance with OPWDD's safety plan, and coordination regarding asbestos and PCB survey information. No explicit pricing terms, set-asides, incumbent information, or funding sources are specified in this design document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIST OF DRAWING
SCALE: NTS
LOCATION MAP
ROOF REPLACEMENT
275 TELEPHONE RD,
WEST HENRIETTA, NY 14586
NEW YORK
STATE OF
OPPORTUNITY
Office for People With Developmental Disabilitis Finger Lakes DDSO 620 Westfall Rd, Rochester, NY 14620
IRA SITE ADDRESS
TELEPHONE ROAD
N
GENERAL NOTES
OCCUPANCY: SINGLE FAMILY RESIDENCE
CODE INFORMATION
HDWD HARD WOOD
HORIZ HORIZONTAL
H.W HOT WATER
H.W.R HOT WATER
RETURNING
HR HOUR
INSUL INSUL
JAN JANITOR
L.F. LINEAL FEET
MAX. MAXIMUM
MECH. MECHANICAL
MEDS. MEDICATION
MIN. MINIMUM
MLDG. MOULDING
M.O. MASONRY OPENING
MTL METAL
N.I.C NOT IN CONTRACT
NTS NOT TO SCALE
O.C. ON CENTER
OPP OPPOSITE
OPP.BLD OPPOSED BLADE
REC. RECREATION
REFL. REFLECTED
REQ`D REQUIRED
RM ROOM
S.F. SQUARE FEET
SIM. SIMILAR
S.S. STAINLESS STEEL
STL. STEEL
STOR. STORAGE
SOL. SOLID SURFACE
PLASTIC
T.S. TOP OF STEEL
TYP. TYPICAL
U.N.O. UNLESS NOTED
OTHERWISE
VCT VINYL COMPOSITION
TILES
V.I.F. VERIFY IN FIELD
W.F WATER FOUNTAIN
W/ WITH
W.O. WINDOW OPENING
ADA AMERICAN DISABILITIES
ACT
A.F.F ABOVE FINISHED
FLOOR
ALUM. ALUMINUM
APPROX APPROXIMATELY
APT. APARTMENT
BLDG BUILDING
CATV CABLE TV
CL CLOSET
CLR. CLEAR
CONC. CONCRETE
CONT. CONTINUOUS
CG. CORNER GUARD
CLNG CEILING
C.M.U CONCRETE MASONRY
UNIT
CONF CONFERENCE
CPT CARPET
C.T. CERAMIC TILE
C.W COLD WATER
DEMO. DEMOLITION
DET. DETAIL
DIR DIRECTOR
DWG. DRAWING
DN. DOWN
ELEC. ELECTRIC
ELEV. ELEVATION
E.O.C EVERY OTHER
COURSE
EQ EQUAL
EXIST. EXISTING
EXP. EXPOSED
FEC FIRE EXTINGUISHER
CLOSET
FF FINISHED FLOOR
FIN. FINISHED
FL FLOOR
GFI GROUND FAULT
INTERRUPTER
GYP BD GYPSUM WALLBOARD
GRD. GRADE
ABBREVIATIONS
SCALE: NTS
SITE PLAN N
G-01 COVER SHEET
A-01 ROOF DEMOLITION & REPLACEMENT PLANS & NOTES
A-02 ROOF DETAILS
1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE GOVERNMENT CODES INCLUDING BUT NOT
LIMITED TO THE "RESIDENTIAL CODE OF NEW YORK STATE", "NEW YORK STATE ENERGY
CONSERVATION CODE", OSHA, ADA AND NFPA & ITS REFERENCED STANDARDS.
2. CONTRACTOR IS TO PERFORM A SITE VISIT TO FAMILIARIZE THEMSELVES WITH
EXISTING CONDITIONS BEFORE SUBMITTING PRICING. THEY SHALL INCLUDE IN THEIR
WORK THE EFFECT OF ALL EXISTING CONDITIONS TO THE WORK.
3. CONTRACTOR SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS AND NOTIFY OPWDD AND
DESIGNER OF ANY INACCURACIES.
4. COMMENCE WORK IMMEDIATELY UPON AWARD OF THE CONTRACT AND PROCEED
DILIGENTLY AND CONTINUOUSLY TO COMPLETION.
5. PRIOR TO STARTING WORK, SUBMIT FOR OWNER'S APPROVAL A DETAILED SCHEDULE
INDICATING ALL WORK THAT MIGHT AFFECT OWNER'S USE OF THE BUILDING, SUCH AS
UTILITY SHUT DOWNS, NOISE GENERATING CONSTRUCTION, ETC.
6. THE EXISTING BUILDING WILL REMAIN IN OPERATION DURING THIS WORK. ENSURE
SAFE PASSAGE OF ALL PERSONS AROUND WORK AREAS. ERECT BARRIERS AS
REQUIRED AND/OR AS DIRECTED BY OWNER. MAINTAIN ALL REQUIRED EGRESS
ROUTES.DO NOT LIMIT OWNERS USE OF BUILDING WITHOUT OWNERS PRIOR APPROVAL.
7. CONTRACTOR SHALL TAKE PRECAUTIONS TO AVOID ANY DISRUPTION, DAMAGE OR
HAZARD TO OWNER AND OWNER'S CLIENTS DURING CONSTRUCTION. MAINTAIN
BUILDING SECURITY AND PROTECTION FOR OCCUPANT'S AND PUBLIC'S SAFETY.
8. DO NOT INTERRUPT EXISTING UTILITY SERVICE WITHOUT AUTHORIZATION FROM
OWNER.PROVIDE TEMPORARY SERVICE DURING INTERRUPTIONS.
9. PERFORM WORK IN A MANNER IN WHICH LIMITS THE AMOUNT OF NOISE AND CONSTRUCTION
TRAFFIC AS MUCH AS POSSIBLE. SCHEDULE OPERATIONS AS MAY BE DIRECTED BY OWNER.
10. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO
COMPLETE THE WORK.
11. PROVIDE ALL MATERIALS AND PERFORM ALL WORK IN ACCORDANCE WITH RECOGNIZED
GOOD STANDARD PRACTICES.
12. ALL MATERIALS SHALL BE AS SPECIFIED, OR EQUIVALENT AS APPROVED BY ARCHITECT.
MATERIALS SPECIFIED INDICATE QUALITY INTENT THAT WILL BE USED AS A BASIS FOR REVIEW
OF SUBSTITUTES.
13. ALL ITEMS WHICH ARE NOT SPECIFICALLY REFERRED TO ON THESE DRAWINGS ARE TO BE
SELECTED BY THE OWNER FROM THE MANUFACTURER'S STANDARD SAMPLES SHOWING FULL
RANGE OF TEXTURES AND COLORS AVAILABLE.
14. FOLLOW MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS FOR INSTALLATION OF ALL
MATERIALS.
15. THE WORDS "PROVIDE" OR "SUPPLY" SHALL INCLUDE BOTH FURNISHING AND INSTALLING THE
SPECIFIED OR DETAILED ITEM, IN PLACE AND READY FOR OPERATION AND USE.
16. CONTRACTOR SHALL STORE MATERIALS IN AREAS DESIGNATED BY OWNER. DELIVERY OF
MATERIALS SHALL BE AS DIRECTED BY OWNER.
17. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK.
18. ALL DIMENSIONS SHALL BE FIELD VERIFIED. DO NOT SCALE DRAWINGS. INDICATED
DIMENSIONS ARE TO CENTERLINE OF STEEL, FACE OF EXISTING GYPSUM BOARD
PARTITIONS, FACE OF STUDS AT NEW GYPSUM BOARD PARTITIONS OR FACE OF MASONRY.
19. MINOR ITEMS OF WORK SUCH AS CUTTING, BLOCKING, SHIMMING, TRIM, ETC. SHALL BE
PERFORMED AS REQUIRED TO MAKE THE WORK COMPLETE WHETHER SHOWN OR NOTED ON
THE CONTRACT DOCUMENTS OR NOT.
20. PROVIDE TEMPORARY AND REMOVABLE PROTECTION FOR INSTALLED PRODUCTS.
CONTROL ACTIVITY IN IMMEDIATE WORK AREA TO MINIMIZE DAMAGE.
21. PROVIDE PROTECTIVE COVERINGS AT WALLS, PROJECTIONS, JAMBS, SILLS AND SOFFITS OF
OPENINGS NOT AFFECTED BY CONSTRUCTION.
22. CONTROL ACCUMULATION OF WASTE MATERIALS AND RUBBISH DURING CONSTRUCTION.
LEAVE PROJECT AREA BROOM CLEAN AT THE END OF EACH DAY. REMOVE ALL DEBRIS FROM
THE SITE IN ACCORDANCE WITH STATE AND LOCAL CODES. COORDINATE REMOVAL WITH
OWNER.
23. PERFORM FINAL CLEANING AT THE END OF THE CONTRACT. CLEAN INTERIOR SURFACES,
EQUIPMENT AND FIXTURES. REPLACE FILTERS AT MECHANICAL EQUIPMENT.
24. REFER TO ASBESTOS ABATEMENT SHEET AND SPECIFICATIONS .
CONSTRUCTION CLASSIFICATION: TYPE 5-B CODE
COMPLIANCE: 2025 NYS RESIDENTIAL CODE.
CONSTRUCTION CLASSIFICATION: LEVEL 2 ALTERATION.
NFPA LSC: CHAPTER 33 EXISTING BOARD
AND CARE
25. CONTRACTOR IS RESPONSIBLE FOR PROPER AND LEGAL DESPOSAL OF ALL CONSTRUCTION
DEBRIS TO PROPER LAND FILL.
HE
C
Pr oj ec t N o.
P
ER
M
IT
S
ET
DA
TE
: 1 0/
/2
TE
LE
PH
O
N E
RD
, W
ES
T
HE
N
RI
ET
TA
, N
Y
TE
LE
PH
O
N E
RO
AD
IR
A
RO
O
F
RE
PL
AC
EM
EN
T O
PW
DD
F
LD
DS
O
C M
M F
L2
G01
37-15 73rd St, Room 203 Jackson Heights, NY 11372 wardanj Accepted For Construction
ROOF REMOVAL NOTES:
LEGEND
ROOF UNDERLAYMENT
AREA OF SELF-ADHERING
ICE BARRIER, (TYP)
APPRX.. ROOF PITCH (V:H)
DIRECTION OF ROOF SLOPE
PLUMBING VENT, SEE 4/A-2
EXHAUST FAN
ROOF DEMOLITION NOTES
A. CONTRACTOR SHALL FIELD VERIFY ALL THE
INFORMATION PROVIDED IN THE BID DOCUMENT AND
INFORM OPWDD IF THERE IS ANY DISCREPANCIES.
B. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS AND PROPOSED NEW WORK TO PROVIDE
ALL REMOVALS REQUIRED TO INSTALL NEW WORK,
AND SHALL INFORM OPWDD ABOUT ANY
DISCREPANCIES.
C. OPWDD HAS COMPLETED A LIMITED SURVEY FOR
ASBESTOS AND PCB. COPIES OF THE SURVEY AND
THE ASBESTOS REMOVAL SPECIFICATIONS CAN BE
OBTAINED FROM OPWDD PROJECT MANAGER. IF
SUSPECT MATERIAL, THAT HAVE NOT BEEN TESTED,
ARE ENCOUNTERED, NOTIFY THE OPWDD PROJECT
MANAGER, WHO WILL ARRANGE FOR ADDITIONAL
TESTING AND/OR PROVIDE DIRECTION. DO NOT
DISTURB SUSPECT MATERIALS.
D. THE EXISTING BUILDING WILL BE OCCUPIED
DURING ROOFING OPERATIONS. THE CONTRACTOR
SHALL MAINTAIN EXISTING EXITS (PROVIDE
OVERHEAD PROTECTION WHERE NECESSARY,
REGULATE NOISE AND TRAFFIC).
REMOVE EXISTING SHINGLE ROOFING SYSTEM
(INCLUDING BUT NOT LIMITED TO ASPHALT SHINGLES,
MEMBRANE/UNDERLAYMENT, METAL FLASHING,
DOWN TO EXISTING ROOF SHEATHING.
REMOVE EXISTING SHEATHING THAT HAS BEEN
DAMAGED. ASSUME 5% OF TOTAL AREA FOR BIDDING.
ROOF INSTALLATION GENERAL NOTES NEW WORK NOTES:
1. CONTRACTOR TO FIELD VERIFY ALL
WORK & DIMENSIONS, IN THE FIELD, PRIOR TO
COMMENCEMENT OF WORK. NOTIFY OPWDD
REPRESENTATIVE OF ANY DISCREPANCIES.
2. CONTRACTOR IS RESPONSIBLE TO REPAIR
DAMAGE TO EXISTING CONDITIONS, THAT
RESULTS FROM THE CONSTRUCTION OF THIS WORK.
3. CONTRACTOR IS RESPONSIBLE TO SECURE &
PROTECT ALL AREAS (INTERIOR & EXTERIOR),
DURING THE DURATION OF THIS WORK.
4. CONTRACTOR TO COORDINATE WITH OPWDD
REPRESENTATIVE REGARDING THE LOCATION OF
STAGING AREA FOR DUMPSTER AND CONSTRUCTION
MATERIALS.
5. THE CONTRACTOR SHALL NOT OVERLOAD ROOF
AREAS. THE QUANTITY OF SHINGLES PERMITTED ON
ROOF AREAS IS THE QUANTITY OF SHINGLES TO BE
INSTALLED ON THAT DAY.
6. THE CONTRACTOR SHALL NOT EXPOSE THE ROOF IF
POOR WEATHER IS FORECASTED FOR THAT DAY.
7. ALL WORK SHALL BE PROTECTED 24 HOURS A DAY 7
DAYS A WEEK TO PREVENT WATER LEAKS AND DAMAGE
TO OCCUPIED HOME. THE CONTRACTOR SHALL BE
REQUIRED TO ADDRESS ANY DAMAGED WORK AREAS
DUE TO LEAKS DURING CONSTRUCTION AT THEIR OWN
EXPENSES.
8. THE CONTRACTOR SHALL PROPERLY CLEAN
SITE OF ANY AND ALL DEBRIS (ESPECIALLY NAILS) FROM
WORK SITE EACH DAY.
9. THE CONTRACTOR SHALL COMPLY WITH OPWDD
SAFETY PLAN.
10. ALL WORK SCHEDULES SHALL BE COORDINATED AND
APPROVED BY OPWDD FIELD REPRESENTATIVES.
11. ALL COLOR SELECTIONS SHALL BE DETERMINED BY
OPWDD FIELD REPRESENTATIVE.
12. NOTIFY THE OPWDD FIELD REPRESENTATIVE IF
ADDITIONAL SUSPECT MATERIALS ARE ENCOUNTERED.
DO NOT DISTURB THESE MATERIALS UNTIL THEY ARE
TESTED, AND DIRECTION IS GIVEN BY THE OPWDD FIELD
REPRESENTATIVE.
13. THE CONTRACTOR SHALL INSTALL ALL ROOFING
MATERIALS PER MANUFACTURER'S SPECIFICATIONS.
14. CONTRACTOR TO PROVIDE UNIT PRICE FOR THE REMOVAL
AND REPLACEMENT OF WATER DAMAGED ROOF
SHEATHING. PROVIDE A BASE BID AMOUNT OF 5% OF THE
TOTAL AREA IF WATER DAMAGED SHEATHING IS
ENCOUNTERED. IT IS TO BE VERIFIED FOR REPLACEMENT
WITH OPWDD.
15. ROOF WARRANTY:
MANUFACTURERS LIFETIME WARRANTY FOR THE
SPECIFIC ROOF SHINGLE TYPE SELECTED. AS A
CONDITION OF THE ROOFING MANUFACTURERS
WARRANTY, THE INSTALLER SHALL PROVIDE
CERTIFICATIONS SIGNED BY THE ROOFING SYSTEM
MANUFACTURER INDICATING THAT THE INSTALLER IS
APPROVED, AUTHORIZED, AND OR LICENSED BY THE
MANUFACTURER TO INSTALL THE SPECIFIED ROOFING
SYSTEM FOR THE WARRANTY TO BE IN EFFECT. THIS
CERTIFICATION SHALL IDENTIFY EXPIRATION DATE FOR
CERTIFICATION AND MAXIMUM AREA IN WHICH THE
INSTALLER IS AUTHORIZED TO INSTALL.
A. ROOFING MATERIALS:
1. ASPHALT SHINGLES:
· WARRANTY: MIN. 40 YEARS LIMITED WARRANTY.
· COLOR: AS PER DDSO SELECTION.
· SOURCE: G.A.F. MATERIALS CORP: TIMBERLINE UHD RS,
OR, APPROVED EQUIVALENT.
2. UNDERLAYMENT: 40MIL THICK MINIMUM, POLYETHYLENE
FACED AND REINFORCED, SLIP RESISTANT, COLD APPLIED.
GAF TIGER PAW SYNTHETIC UNDERLAYMENT OR APPROVED
EQUIVALENT.
3. ICE AND WATER BARRIER: 40 MIL SELF ADHERING G.A.F.
WEATHERWATCH, OR APPROVED EQUIVALENT.
4. USU ALUMINUM DRIP EDGE AND STARTER SHINGLES AT AT
THE EDGES.
5. CONTRACTOR WILL CHOOSE MATERIALS FROM SINGLE
SOURCE BASIS OF DESIGN, SO A COHESIVE WARRANTED
SYSTEM IS ACHIEVED.
B. EXISTING ROOF DECK: REPLACE SHEATHING AS REQUIRED
WITH CDX PLYWOOD MATCHING THICKNESS OF ADJACENT
EXISTING. PROVIDE 2X WOOD BLOCKING SUPPORTS AS
REQUIRED. STAGGER PANEL END JOINTS. PROVIDE 1/8" SPACE
BETWEEN SHEETS AT ENDS AND SIDE JOINTS. USE EDGE
CLIPS TO PROVIDE SPACING BETWEEN PANELS. GLUE AND
NAIL PLYWOOD TO SUPPORTS.
C. CRICKET: BLOCKING TO BE 2X PRESSURE TREATED,
CONSTRUCTION GRADE SOUTHERN PINE, HEM-FIR, OR
DOUGLAS FIR. PLYWOOD TO BE SAME AS ROOF SHEATHING.
D. METAL FLASHINGS AND TRIM.
· PVDF (KYNAR 500) COATING OR, EQUIVALENT ALUMINUM
· THICKNESS: 0.32" MIN.
· INSTALL PER SMACNA'S "ARCHITECTURAL SHEET METAL
STANDARD"
· REFER TO DETAILS.
E. PROVIDE GALVANIZED ROOF FLASHING WITH SELF SEALING
COLLAR OVER VENT STACKS AT ROOF
· OATEY COMPANY (BASIS OF DESIGN)
· OR, APPROVED EQUIVALENT.
· REFER TO DETAILS.
SCALE: 1/8"=1'-0"
ROOF CONSTRUCTION PLAN2
A01
SCALE: 1/8"=1'-0"
ROOF REMOVAL PLAN1
A01
LINE OF EXTERIOR
FACE OF WALL
BELOW (TYP)
3'-0"
(TYP)
MEASURED
ALONG THE
ROOF SLOPE
A025
A02
A02
A02
A02
A02
A02
A02
A02
PV
± 5:12
PV
A02
3'-0"
TYP
3'-0"
TYP
A02
A02
EF
A02
N
N
A02
A02
LINE OF EXTERIOR
FACE OF WALL
BELOW (TYP)
PV
11 2 2
± 1:6 ± 1:6
2± 1 :6
± 1 :6
1 2
± 1 :6
± 1 :6
11 22
± 1:6 ± 1:6
CHIMNEY
2' -0
EF
EF
PVPV
LP
LP LIGHT POLE
PV
LP
CHIMNEY
PV
THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE
INFORMATION AND SHAL BE USED FOR THEIR
INTENDED PURPOSE. ONCE THE INTENDED PURPOSE
HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN
A SECURE MANNER.
IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY
PERSON UNLESS UNDER HE DIRECTION OF A LICENSED
ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN
ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE
AND ARCHITECT'S/ENGINEER'S SIGNATURE.
COPYRIGHT©2026
Consultants:
HUQ ENGINEERING CONSULTANCY, PLLC
37-15 73rd St, Room 203 Jackson Heights, NY 11372
Phone: 646 283 7675
Revisions:
Drawing Title:
TELEPHONE IRA - ROOF DESIGN
Job Number:
Drawing Number:
A01 Date: Sheet Number:
CMM FL25132
Project:
ROOF DEMOLITION AND
REPLACEMENT PLANS AND NOTES
275 Telephone Rd, West Henrietta, NY 14586
Client:
OFFICE FOR PEOPLE WITH
DEVELOPMENTAL DISABILITIES
620 Westfall Rd, Rochester, NY 14620
FINGER LAKES DDSO
Project Key:
DateDescription
10/23/202690% Permit Set
A
SCALE: NTS
EAVE EXTENSION DETAIL5
A02
CLASS A LAMINATED ASPHALT
SHINGLE, TYPICAL.
EXTENT OF (SELF-ADHERED
UNDERLAYMENT), TYPICAL.
0.032" KYNAR COATED ALUMINUM
TRIM FLASHING. SECURE WITH
ALUMINUM NAILS AT 8" O.C., TYPICAL.
EXISTING TO REMAIN, TYPICAL.
SELF-ADHERING UNDERLAYMENT
TURNED UP WALL AT LEAST
THICKNESS OF TRIM BOARD.
PROVIDE SELF-ADHERING ICE
BARRIER -EXTEND 24-IN. BEYOND
INTERIOR FACE OF
EXTERIOR WALL, TYP.PROVIDE ASPHALT SHINGLES
PROVIDE ASPHALT SHINGLE
STARTER COURSE
SCALE: NTS
EAVE RAKE FLASHING DETAIL6
A02
EAVE B RAKE
PROVIDE DRIP EDGE
METAL FLASHING
5"
5 8"
A
B
PROVIDE SHEET METAL APRON
FLASHING W/ HEMMED EDGE
PROVIDE SEALANT
PROVIDE SHEET METAL
COUNTERFLASHING
PROVIDE SHEET METAL
STEP FLASHING
PROVIDE REGLET
PROVIDE SELF-ADHERING
UNDERLAYMENT TURN UP
WALL 4" & EXTEND BEYOND
ELEMENT 18", TYP.
PROVIDE ASPHALT SHINGLESSOLDER OR SEAL CORNERS
SCALE: NTS
APRON FLASHING DETAIL11
A02
SCALE: NTS
ASPHALT SHINGLE NAILING DETAIL7
A02
12 GAUGE, DEFORMED SHANK, ZINC
COATED ROOF NAIL. NAIL HEAD
SHALL BE 3/8" DIAMETER. NAIL
LENGTH AS REQUIRED TO
PENETRATE ROOF DECK 3/4" MIN. OR
IF PLYWOOD DRIVE THROUGH 1/8",
TYPICAL
ROOF SHEATHING, TYPICAL
MAINTAINSPECIFIEDEXPOSURE
UNDERLAYMENTS, TYPICAL
ASPHALT SHINGLE, TYPICAL
IMPROPERLY DRIVEN NAILS
ASPHALT SHINGLE
UNDERLAYMENT(S)
ROOF SHEATHING
UNDERRIVEN
OVERDRIVEN
ANGLED
ASPHALT ROOF SHINGLES
SEE PLAN, TYP.
ROOF UNDERLAYMENT LAP
OVER I&W SHIELD, TYP.
PROVIDE NEW 4" DUCT TO DRYER.
PROVIDE DUCT INSULATION AT ATTIC.
PROVIDE NEW DRYER VENT HOOD
(FANTECH RC4P ROOF CAP, OR
EQUIVALENT)
ROOF CAP FLASHING
FLANGE, TYP. PROVIDE SELF-ADHERING
SHEET UNDERLAYMENT, TYP.
MINIMUM 1'-6" FROM
EXHAUST FAN FLASHING, TYP.
ROOF UNDERLAYMENT, TYP.
SCALE: NTS
INTAKE VENT FLASHING DETAIL3
A02
EXIST. TOP CHORD
OF TRUSS, TYP.
ROOF SHEATHING, TYP.
VENT PIPE, EXIST.
18" SQUARE OF SELF ADHERING
SHEET UNDERLAYMENT. CUT
SNUG AROUND VENT PIPE AS
SHOWN.
DESIGNER NOTE: VERIFY EXTENSION
OF PLG VENT PIPES CONFORMANCE
TO NYSPC, TYP.
TRIM SHINGLE IN MANNER TO
RECEIVE VENT PIPE FLASHING
SET LOWER PORTION OF
FLASHING IN SEALANT, TYP.
(OPTIONAL)
BIND NAIL 1" ABOVE LAST
SHINGLE LAP, TYP.
INSTALL ALUMINUM NO CAULK
FLASHING 18"X18" NEW VENT
PIPE FLASHING OVER VENT PIPE.
INSTALL FLASHING AS PER
MANUFACTURERS INSTALLATION
GUIDE.
SECTION VIEW
1 2
3 4
SCALE: NTS
VENT STACK FLASHING DETAIL4
A02
PROVIDE "T" TYPE
EDGE METAL
FLASHING
CONTINUOUS ICE AND WATER
SHIELD UNDERLAYMENT AT
VALLEY. 18" MINIMUM COVERAGE
EACH SIDE OF VALLEY, TYP.
C OF VALLEY.
ALTERNATE BETWEEN 12" MIN
AND 18" MAX OVERLAP BEYOND
CENTER OF VALLEY TO MAINTAIN
SHINGLE COURSING, TYP.
ASPHALT SHINGLES, TYP.
NOTE: EXTEND EACH SHINGLE END 18" MIN. BEYOND VALLEY
CENTER. DO NOT NAIL CLOSER THAN 6" TO VALLEY CENTER
UNDERLAYMENT
OVER ICE AND
WATER SHIELD, TYP.
6" MIN LAP OF
SCALE: NTS
ROOF EAVE WITH GUTTER8
A02
SCALE: NTS
VALLEY DETAIL12
A02
18" MIN.
6"MIN.
L
EXISTING OR NEW (TO MATCH) PLYWOOD
SHEATHING. SEE ROOF PLAN.
CLASS A LAMINATED ASPHALT
SHINGLE, TYPICAL.
EXTENT OF (SELF-ADHERED ICE
BARRIER), TYPICAL.
0.032" KYNAR COATED ALUMINUM TRIM
FLASHING. SECURE WITH ALUMINUM
NAILS AT 8" O.C., TYPICAL.
1x8 WOOD FASCIA
EXISTING FASCIA/ VENT
EXISTING STONE VENEER
THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE
INFORMATION AND SHAL BE USED FOR THEIR
INTENDED PURPOSE. ONCE THE INTENDED PURPOSE
HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN
A SECURE MANNER.
IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY
PERSON UNLESS UNDER HE DIRECTION OF A LICENSED
ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN
ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE
AND ARCHITECT'S/ENGINEER'S SIGNATURE.
COPYRIGHT©2026
Consultants:
HUQ ENGINEERING CONSULTANCY, PLLC
37-15 73rd St, Room 203 Jackson Heights, NY 11372
Phone: 646 283 7675
Revisions:
Drawing Title:
TELEPHONE IRA - ROOF DESIGN
Job Number:
Drawing Number:
A02 Date: Sheet Number:
CMM FL25132
Project:
ROOF DETAILS
275 Telephone Rd, West Henrietta, NY 14586
Client:
OFFICE FOR PEOPLE WITH
DEVELOPMENTAL DISABILITIES
620 Westfall Rd, Rochester, NY 14620
FINGER LAKES DDSO
Project Key:
DateDescription
10/23/202690% Permit Set
| G-01 |
| Sheets and Views |
| G-01 |
| A-01 |
| Sheets and Views |
| A-01 |
| A-02 |
| Sheets and Views |
| A-02 |