AF182-012: Autonomous Measurement and Reporting of Fluorocarbons in Groundwater
PROJECTED CMMC LEVEL REQUIREMENT:
N/A
TECHNOLOGY AREAS:
Materials
MODERNIZATION PRIORITIES:
KEYWORDS:
AFFF, fluorocarbon, groundwater, PFOA, PFOS
ADDITIONAL INFORMATION
OBJECTIVE:
An autonomous system that measures and reports the concentration of functionalized perfluorocarbons in groundwater.
DESCRIPTION:
Fluorochemicals have been a significant factor in industrial chemistry for roughly a century. As one of their usages, AFFF based on perfluorooctyl-substituted surfactants was for decades the water-based firefighting agent of choice in military and civilian applications until it was determined that two highly persistent, bioaccumulative compounds formed from decomposition of AFFF—perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS)—pose a health risk and display unacceptable toxicity to aquatic index organisms. The shorter-chain homologue now used for firefighting is considered a temporary patch, in anticipation of an environmentally compatible next-generation agent and of adverse findings of toxicity in the materials and their by-products.
Purge-and-trap methods coupled with gas chromatography (GC) and flame- or photo-ionization detection have been standard technology to measure Volatile Organic Compounds (VOCs) in various waters for three decades.
More recently the analytical process has been relocated to the field and integrated with autonomous sample collection and data processing technologies to create self-reporting monitors that have achieved regulatory acceptance. The same concept is applicable in principle to fluorocarbon derivatives (FCs), but Maximum Contaminant Levels for VOCs are at least 2 orders of magnitude higher than for PFOS and PFOA, which are effectively involatile, and FCs yield much weaker ionization responses than VOCs that contain H atoms. This topic seeks to develop an analytical method that concentrates FCs from water, calculates the original concentration from an automated measurement, performs any other tasks needed to label and package the data for reporting, and transmits it securely to designated recipients. Maintenance intervals are to be at least 6 months, and the unit is to be self-powered, with self-rechargeable backup battery capacity for 3 or more days, and to issue immediate notification in the event of a power failure. The system should employ no Hazardous Materials or Ozone-Depleting Chemicals, and may emit no interfering electromagnetic signal and no contaminants to air or water except residues from the water samples analyzed.
PHASE I:
Demonstrate a reproducible calibration curve to a Method Detection Limit (MDL) of 10 parts per trillion or less for PFOA and for PFOS, in water. Deliverable is a technical report detailing the analytical method and supporting data.
PHASE II:
Elaborate the phase I analytical method into a field-testable prototype system that autonomously accepts a sample from a flowing source (including groundwater), completes the analysis, and transmits an electronic record of the time and analytical result at intervals of 12 hours, no more than two hours after sampling is completed.
PHASE III DUAL USE APPLICATIONS:
Integrate battery, power source, and GPS and environmental condition reporting into a production-ready monitoring-and-reporting system, and submit data as required to initiate regulatory validation and certification of the method and device.
REFERENCES:
American Wastewater Association, Treatment and Removal of PFCs, www.awwa.org/Portals/0/files/legreg/documents/AWWAPFCFactSheetTreatmentandRemoval.pdf
1.
Arathy S Nair, DuPont settles lawsuits over leak of chemical used to make Teflon, http://www.reuters.com/article/us-du-pont-lawsuit-west-virginia-idUSKBN15S18U
2.
Determination of Selected Perfluorinated Alkyl Acids in Drinking Water by Solid Phase Extraction and Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS), https://cfpub.epa.gov/si/si_public_file_download.cfm?p_download_id=525468
3.
TECHNICAL POINT OF CONTACT (TPOC):
None
File details come from the government source that posted it. Updated .