AF171-001: Variable Pressure/Flow Control Firefighting Nozzle
PROJECTED CMMC LEVEL REQUIREMENT:
N/A
TECHNOLOGY AREAS:
Materials
MODERNIZATION PRIORITIES:
KEYWORDS:
Fire, Firefighting, Mist, Nozzle, Pressure, Stream, Water
ADDITIONAL INFORMATION
OBJECTIVE:
Develop a hose-end nozzle system capable of allowing the operator to hand select discharges of Ultrahigh- Pressure (UHP; 1100 to 1500 PSI @ 15 to 20 GPM) and low-pressure (LP; 100 PSI @ 15 to 20 GPM) water streams at variable flow rates through a single hose line and application nozzle.
DESCRIPTION:
UHP and LP nozzle technologies already exist and are commercially available, although no one nozzle is capable of providing both UHP and LP water streams. A variable-pressure/flow-control nozzle will allow the first responder the option to utilize, as applicable, either technology to respond to fire incidents. The nozzle shall be designed to be compatible with the existing 4-stage centrifugal pump and 200 ft of 1-in high-pressure hose line mounted on the Air Force P-34 Rapid Intervention Vehicle (RIV). The variable flow nozzle should be easily handled with similar design to existing firefighting nozzles i.e. with pistol grips and bails as needed to operate the nozzle. The ability to control the nozzle discharge in either UHP or LP shall be by a simple means of a nozzle bail or trigger and or combination of each for the discharge of water thorough the nozzle at variable flow rates. The application nozzle shall also be capable of straight and or fog patterns as selected by the operator. Candidate technologies should balance commercial considerations with DoD requirements.
PHASE I:
R&D goals of phase I are to identify the possibility of using a single pump, hose and nozzle system to provide both UHP and low-pressure waster flows between 15 and 20 GPM at variable pressures from 100 to 1500 PSI Phase I deliverable is design specifications. Offerors are encouraged to work with AFCEC's Fire Research Group during the design stage.
PHASE II:
Produce a full-scale prototype nozzle. Provide detailed specifications of max and min pressure, GPM and capabilities of the nozzle. Conduct a full-scale demonstration of the nozzle at AFCEC's Fire Research Facilities
PHASE III DUAL USE APPLICATIONS:
Deliver a marketable product with detailed installation/operator guidance manual.
REFERENCES:
http://www.dodfirenews.com/p-34.html1.
http://www.afcec.af.mil/news/story.asp?id=1233610142.
http://www.fireengineering.com/articles/print/volume-165/issue-11/features/ultra-high-pressure-firefighting-technology.html
3.
National Fire Protection Association (NFPA) Standards http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards
4.
TECHNICAL POINT OF CONTACT (TPOC):
None
File details come from the government source that posted it. Updated .