AF112-205: Improved Energy Conservation for Data Centers

PROJECTED CMMC LEVEL REQUIREMENT:

N/A

TECHNOLOGY AREAS:

Materials

MODERNIZATION PRIORITIES:

KEYWORDS:

energy reduction, data centers, net servers, conservation

ADDITIONAL INFORMATION

OBJECTIVE:

Improve data center energy efficiency through the development of new technologies and practices.

DESCRIPTION:

Data centers typically use quite a bit of energy. Nationally, data center electrical use has more than doubled between 2000 and 2006, and is expected to double again by 2011. Based on research, there are estimates that the global IT industry can offset 38 million metric tons of Carbon Dioxide (CO2) emissions by 2015 through the development and deployment of more energy efficient networking equipment worldwide. This is equivalent to $5 billion in energy cost savings. Servers are typically on-line 24 hours a day, 7 days a week, handling e-mails, processing internet requests, safeguarding classified data, handling financial transactions, and storing video and medical records. The use of the internet will only increase as more and more applications are developed and expanded. It is estimated from Google that only 20% (1.5 billion) of the world population is currently on-line. As these needs have progressed, the capacity of the servers has increased. This increased capacity has led to an increase in the heat output per server and increased the overall energy needs. The US government is interested in decreasing overall energy usage. Data servers present a concentrated area for energy efficiency. If the general population can reduce the overall amount of energy that network-supporting equipment uses this would help businesses and consumers save money by lowering their energy costs. The average data center uses half the energy to run its processors, and the other half is used to cool the facility. Areas to be improved include computing software, computing, storage and network hardware, the power conversion chain, heat removal, and controls.

There are several long term opportunities to improve data center energy efficiency through the development of new technologies and practices. This topic would research and develop improved methods of dealing with data center energy usage, focusing on either one area or a combination of several areas.

PHASE I:

Research and develop concepts to reduce overall energy usage. Estimate energy savings for each concept suggested. Show how the technology could be easily adapted to industry.

PHASE II:

Further develop most promising energy reduction strategies from phase I. Provide a final report that will document validated results, measured metrics and benefits.

PHASE III DUAL USE APPLICATIONS:

DUAL USE COMMERCIALIZATION: Military Application: Applications would apply to any improved energy usage such as data centers in military areas. Commercial Application: Any large data centers would use this improved technology to decrease their costs. This could include internet servers, large companies, or even small governments.

REFERENCES:

Report to Congress on Server and Data Center Energy Efficiency, Public Law 109-431, US EPA Energy Star Program, August 2, 2007.

http://www.energystar.gov/ia/partners/prod_development/downloads/EPA_Datacenter_Report_Congress _Final1.pdf.

1.

Energy Star Data Center Energy Efficiency Initiatives, http://www.energystar.gov/index.cfm?c=prod_development.server_efficiency

2.

TECHNICAL POINT OF CONTACT (TPOC):