ADDITIONAL TECHNICAL SPECIFICATIONS

1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) LINE CODING: B3ZS. FRAME FORMAT: C-BIT.

(B) CHANNELIZATION REQUIRED: 28 T-1'S.

(C) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY,

SEVEN DAYS PER WEEK, AT LEAST 99.95% OF THE TIME.

(D) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO INITIATE REPAIR ONCE THE

TROUBLE-CALL HAS BEEN REPORTED OR IAW THE CONTRACT.

(E) GFE CLOCKING. VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO

CIRCUIT.

(F) COAX BNC TERMINATIONS.

(G) NO NETWORK INTERFACE UNIT.

(H) DEDICATED PATH.

(I) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.

(J) VENDOR MUST PROVIDE THE 1-800 TROUBLE REPORT NUMBER, LONG HAUL CIRCUIT

NO., AND LOCAL CIRCUIT IDENTIFIER AS APPLICABLE FOR EACH END LOCATION TO THE

ACCEPTING AUTHORITY PRIOR TO THE GOVERNMENT ACCEPTING SERVICE.

VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF DS-3 SERVICE IAW

THE UNIQUE INSTALLATION FACTORS.

INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS.

VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO

REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS.

FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT

PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE

CONTACT THE DISN CUSTOMER CONTACT CENTER (DCCC) SCOTT AFB, IL. TOLL FREE: 1-

855-868-9500, COML: 618-418-9500, DSN: 312-418-9500.

MINIMUM TECHNICAL SPECIFICATIONS:

MEASUREMENT INTERVAL (TEST PERIOD): 24 HOURS.

99 PERCENT ERROR FREE SECONDS OVER THE 24 HOUR TEST PERIOD.

SEVERELY ERRORED SECONDS: LESS THAN 0.2 PERCENT OVER THE 24 HOUR TEST

PERIOD.

DEGRADED MINUTES: LESS THAN 0.4 PERCENT OVER THE 24 HOUR TEST PERIOD.

BIT ERROR RATE (BER): 1 TIMES 10 TO MINUS 9.

RESIDUAL BIT ERROR RATE (BER): 1 TIMES 10 TO MINUS 8.

AVAILABILITY: 99.95 PERCENT. 8. MTTLBCI (MEAN TIME TO LOSS OF BIT COUNT

INTEGRITY): MAXIMUM OCCURRENCES: 1 (4/24 HOURS)

ROUND TRIP DELAY (RTD) FOR THIS DS-3 WILL BE MEASURED IN MILLISECONDS FROM

THE CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-A TO THE CUSTOMER'S SERVICE

DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR EQUAL TO 10

MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION. THE

GOVERNMENT M. REMARKS CONTINUED: ACCEPTING AUTHORITY WILL CONFIRM THE

RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE

CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO IMMEDIATELY IN WRITING.