Addendum Two .pdf
PDF 7 MB Posted
- Attached to
- RFB-190-24 KCTCS JCTC Construct Parking Garage
- Solicitation number
- RFB-785-2400000413-4
- Issued by
- Jefferson County, Louisville City, Kentucky
About this file
This document is an Addendum Two to an Invitation to Bid (ITB) issued by the Commonwealth of Kentucky Department for Facilities and Support Services Division of Engineering and Contract Administration for the Re-Ad of RFB-98-24 Construct Parking Garage at KCTCS- Jefferson Community & Technical College in Louisville, Kentucky. The addendum clarifies and modifies the requirements of the plans and specifications for the project, including changes to the site/civil, structural, and architectural drawings and specifications. Key changes include revisions to site demolition, foundation details, column and beam reinforcement, and slab and wall construction.
The addendum also includes a preliminary pile cap schedule and column reaction schedule for the project. Pricing and bidding is to be based on 18" diameter, 75-foot length auger cast piles, though an alternate option for 16" diameter, 55-foot length piles is provided. The addendum requires the general contractor to fully performance design the auger cast piles and associated pile caps. The project is being bid as a single phase of construction, though the structural plans also accommodate a future vertical expansion phase.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-190-24
FOR: Re-Ad of RFB-98-24 Construct Parking Garage KCTCS- Jefferson Community & Technical College Louisville, Kentucky
DATE: March 3, 2024
RFB-785-2400000413
ADDENDUM NO. Two (2)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-190-24 For: Re-Ad of RFB-98-24 Construct Parking Garage KCTCS- Jefferson Community & Technical College Louisville, Kentucky
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
ADDENDUM NO. 2
RE-AD OF RFB-98-24
JEFFERSON COMMUNITY & TECHNICAL COLLEGE
CONSTRUCT PARKING GARAGE
TO: ALL PLAN HOLDERS
FROM: Sherman-Carter-Barnhart Architects, PLLC 144 Turner Commons Way Suite 110 Lexington, KY 40508
DATE: March 1, 2024
The purpose of this Addendum is to clarify the requirements of the Plans and Specifications.
The bidders shall be governed by the information in this Addendum as if included in the Plans and Specifications.
This Addendum does hereby become a part of the Contract Documents.
Each bidder shall acknowledge receipt of this Addendum on the space provided in the Bid Form.
This addendum consists of 45 page(s).
A. PROJECT MANUAL
1. Unless noted otherwise, the following shall apply to all manufacturers listed throughout the construction documents: Subject to compliance with Contract Documents, manufacturers listed are approved as a manufacturer only. This does not imply that specific products supplied by such manufacturers have been reviewed and comply with requirements. It shall be the manufacturer's / contractor's responsibility to ensure that all requirements of the Contract Documents are met, including but not limited to the requirements for matching of specific finishes. “Standard” products that do not meet all requirements of the Contract Documents will not be accepted. As required to meet the requirements of the Contract Documents, custom products may be required from certain manufacturers. Unless noted otherwise by the Architect or Contractor for specific substitutions, the contractor supplying any substituted products shall be responsible for any additional costs associated with the use of such substitutions regardless of the trade or bid package affected.
111250 Parking Control Equipment - Harding
B. SITE / CIVIL
1. Replace Sheet DS1.0 with revised Sheet DS1.0.
2. Replace Sheet SD1.0 with revised Sheet SD1.0.
3. Refer to Sheet L-1.0. Gravel Strip shown at perimeter of building shall include landscape fabric for weed control beneath. Washed river gravel is an acceptable alternative.
4. Clarification: Asphalt Shavings can be Utilized for fill under building slab on Grade to balance the site material. Material has to be just asphalt shavings and can not be mixed with any other on-site materials.
C. STRUCTURAL
1. Replace sheet.S.01 with revised sheet S.01.
2. Replace sheet. S1.0 with revised sheet S1.0.
3. Replace sheet S1.5 with revised sheet S1.5.
4. Replace sheet S3.1 with revised sheet S3.1.
5. Replace sheet S3.2 with revised sheet S3.2.
6. Replace sheet S6.2 with revised sheet S6.2.
7. Replace sheet S6.3 with revised sheet S6.3.
8. Replace sheet S6.4 with revised sheet S6.4.
D. SPECIFICATIONS
1. Refer to Table of Contents.
a. Add 078446 – Fire Resistive Joint Systems.
b. Add 079500 – Expansion Joint Systems.
2. Refer to Specification Section 042000 – Unit Masonry. Refer to paragraph 2.6, item B. Add to No. 1, Equal by Beldon, Glen Gery, Mutual Material.
3. Refer to Specification Section 052130 – Pipe and Tube Railings. Add Sheet 1 to front of specification.
4. Refer to Specification Section 055000 – Metal Fabrications.
a. Refer to page 1.2 Summary, Item A. Add No. 8 as follows: All steel shown on architectural drawings regardless if shown on structural drawings are included in contract.
b. Refer to page 347, paragraph 3.5; Item 2. Add toB as follows: Basis-of-design for stair nosings: Amstep Products equal by Babcock-Davis, American Floor Matt.
5. Refer to attached Specification Section 072726 – Fluid Applied Membrane Air and Water Barrier. Add to Project Manual update.
6. Refer to Specification Section 074140 – Horizontal Formed Metal Wall Panel. Refer to paragraph 2.2 Metal Wall Panels.
A. Basis of Design Product:
1. Revise to Imetco “Latitude”; Equal : Centria, Firestone.
7. Refer to attached Specification Section 074141 – Perforated and Corrugated for Metal Wall Panel. Add to Project Manual. Update Table of Contents accordingly.
8. Refer to Specification Section 079020 – Garage Waterproofing System / Expansion Joints.
a. Refer to paragraph E; Structural Expansion and Joint Sealing Systems. No. 2 clarification: All items listed are shown on Sheet S.04 with a 2” Joint to find proper expansion joint model number.
b. Refer to paragraph 2F. Item a. Expansion Joint Sealing Systems shown 1-8 are listed on architectural drawing as Typical Keynote 2F.
9. Refer to Specification Section 079500 – Expansion Joints.
a. Refer to 1.02. Delete 3 in its entirety.
b. Refer to 2.03. Replace as follows:
1. Application: Interior Wall.
2. Installation: Recessed / Applied.
a.) Clear anodic Class 3.
3. Product: Inpro 114 Series; Equal by W.R. Meadows. CS
9. Refer to Specification Section 083000 – Coiling Grilles. Refer to paragraph 1.8 Warranty – Delete Item A.
10. Refer to Specification Section 111201 – Parking Control Equipment. Refer to paragraph 1, Item 1. Add: Amano McGann, Basis-of-Design; equal by Whitaker, Controlled Products Systems Group.
11. Refer to Specification Section 111250 – Parking Guidance System. Refer to paragraph 2.1; Item B; Add PMC, Dakronics.
D. ARCHITECTURAL DRAWINGS
1. Refer to Sheet A0.1.
a. Refer to Room Finish Groups General Notes. See RFG.7 – Add all exposed CMU exposed to parking deck areas is to be painted. No other room finish group information required for parking deck areas.
b. Refer to Wall / Partition Schedule. Refer to Wall Type 2 and 2A. Delete perlite insulation for both wall types in its entirety.
c. Refer to Wall / Partition Schedule. Refer to Wall Types B, B1, B2, C, G, H, H1, H2, K, and K2. Replace self-adhered ice and water shield with fluid applied air barrier.
Coordinate at all locations for wall types are shown in documents.
2. Replace Sheet PH.1 with revised Sheet PH.1.
3. Refer to Sheet A1.1. Refer to Tenant Spaces 106 – 110. Delete Keynote 7M at these spaces.
4. Replace Sheet A2.3 with revised Sheet A2.3.
5. Replace Sheet A3.1 with revised Sheet A3.1.
6. Replace Sheet A3.2 with revised Sheet A3.2.
7. Replace Sheet A3.3 with revised Sheet A3.3.
8. Replace Sheet A4.1 with revised Sheet A4.1.
9. Replace Sheet A5.1 with revised Sheet A5.1.
10. Replace Sheet A6.1 with revised Sheet A6.1.
11. Replace Sheet A6.2 with revised Sheet A6.2.
12. Replace Sheet A6.5 with revised Sheet A6.5.
13. Replace Sheet A7.1 with revised Sheet A7.1.
a. Delete reference to R11 batt insulation at Security Office 104 on 1/A7.1.
b. Refer to 1/A7.1. Add Keynote 7M above ceiling.
14. Refer to Sheet A8.1.
a. Door Schedule; Door 117. Delete Remark 1.
b. Refer to Detail 5/A8.1. Lintel shown is by Specification 042000 Masonry, Basis-of- Design 4x4x1/4” steel angle. Refer to 055000 for steel lintel requirements.
15. Refer to Sheet 8.2. Refer to Frame Elevation / Glazing Legend. Delete references to spandrel glazing and custom color spandrel glazing.
16. Refer to Sheet 8.3. Refer to Frame Elevation / Glazing Legend. Delete references to spandrel glazing and custom color spandrel glazing.
F. Mechanical / Electrical / Plumbing
1. Refer to attached items
End of Addendum
G A
S
X X X X X
X
X
X
X X
G A
S
GASGASGASGASGASG
A
S
GASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS
G A
S G
A S
G A
S G
A S
G A
S G
A S
G A
S G
A S
G A
S G
A S
G A
S G
A S
G A
S G
A S
G A
S
G A
S G
A S
G A
S
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS G
AS
G
AS
SS
SS
SSSSSSSSSSSSSSSSSSSSSS
X X
X X
X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X X
X X
X X
X X
X X
X
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
SS
REMOVE WALL
REMOVE
C0NCRETE
CURB & GUTTER
REMOVE
C0NCRETE
CURB & GUTTER
REMOVE
TRAFFIC
ISLAND
REMOVE
C0NCRETE
CURB & GUTTER
REMOVE
C0NCRETE
CURB & GUTTER
REMOVE
C0NCRETE
CURB & GUTTER
REMOVE
TRAFFIC ARMS (2)
& SUPPORT
ELECTRONICS
REMOVE
TRAFFIC ARMS (2)
& SUPPORT
ELECTRONICS
REMOVE
TRAFFIC
BOLLARDS (4)
REMOVE
TRAFFIC
BOLLARDS (4)
SAWCUT AND REMOVE
ASPHALT AND STONE BASE
COMPLETELY
SAWCUT AND REMOVE
ASPHALT AND STONE BASE
COMPLETELY
REMOVE
TRAFFIC
ISLAND
REMOVE
TRAFFIC ARMS (2)
& SUPPORT
ELECTRONICS
REMOVE
TRAFFIC ARMS (2)
& SUPPORT
ELECTRONICS
REMOVE
TRAFFIC
BOLLARDS (8)
REMOVE
C0NCRETE
CURB & GUTTER
REMOVE
C0NCRETE
CURB & GUTTER
SAWCUT AND REMOVE
ASPHALT AND STONE BASE
COMPLETELY
REMOVE TREE
DISSASSEMBLE ENTIRE
MONUMENT, SIGNAGE AND
LIGHTING AS PRACTICAL
AND RETURN TO OWNER
FOR STORAGE FOR FUTURE
RELOCATION. (NIC)
DEMOLISH AND REMOVE
SIGN FOUNDATION.
LIMITS OF CONSTRUCTION
LIMITS OF CONSTRUCTION
REMOVE
TRAFFIC
BOLLARDS (4)
REMOVE
TRAFFIC
BOLLARDS (4)
2'-
0"
7'-
0"
6'-0"
6'-0"
'-0
21'-2"
'- 0
REMOVE SIGN.
STORE FOR
FUTURE
RELOCATION
LIMITS OF CONSTRUCTION
X P ro je c ts
\2
\2
\6 S
IT
E
\2
S
D X
.d w g
D a y
T im e
F b
:1 p m
L o g in N a m d ia z
S h e e t L a y o u t:
M
O D
E L
DRAWING NO.
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
RTA DATE
DRAWING INFORMATION
DRAWING DATE 08/07/2023
DRAWN BY
CHECKED BY
A&E FILE NO.
01/26/2024
PHASE RTA
470-CAJL-JF45 00
ACCOUNT NO.
DATEDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWING
DATEDESCRIPTION OF REVISIONS
SHERMAN CARTER BARNHART, PLLC
144 TURNER COMMONS WAY, SUITE 110
LEXINGTON, KY 40508
PHONE: 859.224.1351
FAX: 859.224.8446
DECA LOG #
AS BUILT DATE
MM/DD/YR
BKL
CONSTRUCT PARKING GARAGE /
JEFFERSON COMMUNITY AND TECHNICAL COLLEGE
WM # 10995
ADDENDUM #1 11/08/23
ADDENDUM #2 02/29/24
DS-1.0
CONTRACTOR SHALL REMOVE EXISTING ASPHALT AND STONE BASE
COMPLETELY. UNDERCUT SUBGRADE MATERIAL AS REQUIRED TO
CONSTRUCT NEW ASPHALT SECTION. TOP ON NEW ASPHALT SHALL BE
FLUSH WITH TOP OF ADJACENT EXISTING ASPHALT.
JOB SITE SAFETY
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY DURING
CONSTRUCTION. JOB SITE SAFETY IS OUTSIDE THE SCOPE OF WORK OF
SHERMAN CARTER BARNHART (SCB). NEITHER THE PROFESSIONAL ACTIVITIES
OR THE PRESENCE OF SCB EMPLOYEES OR SUBCONSULTANTS AT THE
CONSTRUCTION SITE SHALL RELIEVE THE CONTRACTOR OR ANY OTHER ENTITY
OF THEIR OBLIGATION, DUTIES, AND RESPONSIBILITIES INCLUDED, BUT NOT
LIMITED TO, CONSTRUCTION MEANS, METHODS, SEQUENCES, TECHNIQUES, TO
PROCEDURES NECESSARY FOR PERFORMING SUPERINTENDING OR
COORDINATING ALL PORTIONS OF THE WORK OF CONSTRUCTION IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS AND ANY HEALTH AND SAFETY
PRECAUTIONS REQUIRED BY GOOD CONSTRUCTION PRACTICES OR ANY
REGULATORY AGENCIES. ANYONE USING INFORMATION FROM THESE PLANS
ACKNOWLEDGES AND WARRANTS THAT SHERMAN CARTER BARNHART IS NOT
RESPONSIBLE FOR SITE SAFETY IN ANY WAY.
1. SITE DEMOLITION DRAWINGS ARE INTENDED TO GENERALLY SHOW THE
DEMOLITION NECESSARY TO COMPLETE THE NEW WORK. THE CONTRACTOR
SHALL REVIEW ALL DOCUMENTS AND VISIT AND OBSERVE THE SITE PRIOR TO
SUBMITTING HIS BID AND SHALL INCLUDE IN HIS BID ALL WORK NECESSARY TO
ACCOMPLISH THE NEW WORK, WHETHER OR NOT SHOWN ON THESE
DEMOLITION DRAWINGS.
2. ALL TREES ARE TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE.
3. REFER TO SITE UTILITY PLANS FOR DEMOLITION AND/OR RELOCATION OF
UTILITIES.
4. FOR CONCRETE REMOVAL, REMOVE TO THE NEAREST CONSTRUCTION
JOINT. PROVIDE A CLEAN SAW CUT JOINT TO ALL EXISTING EDGES OF
CONCRETE TO REMAIN.
5. ALL DEMOLISHED MATERIALS NOT SPECIFICALLY NOTED TO BE
RETURNED TO OWNER, ARE TO BE PROPERLY DISPOSED OF OFFSITE.
6. ALL FOUND MEMORIAL MONUMENTS SHALL BE SALVAGED AND
RETURNED TO OWNER.
7. ALL EXISTING SITE FURNISHINGS AND TRASH RECEPTACLES, WITHIN
DEMOLITION AREAS, SHALL BE SALVAGED AND RETURNED TO OWNER.
8. WHERE STORM DEMOLITION OCCURS WITHIN FOOTPRINT OF NEW
BUILDING ADDITIONS AND NEW PAVEMENT AREAS, CONTRACTOR SHALL
BACKFILL TRENCHES WITH COMPACTED DGA.
GENERAL DEMOLITION NOTES: UTILITIES
THE UTILITIES ARE SHOWN ON THE DRAWINGS AS ACCURATELY AS THEY HAVE BEEN
PROVIDED TO THE ARCHITECT. THEIR LOCATIONS ARE NOT GUARANTEED. IT IS THE
CONTRACTORS RESPONSIBILITY TO CONTACT ALL UTILITY COMPANIES AND TO HAVE ALL
UTILITIES FIELD LOCATED, PRIOR TO STARTING CONSTRUCTION. THE UTILITIES SHOWN
REPRESENT OBSERVABLE FEATURES ALONG WITH INFORMATION PROVIDED BY THE
RESPECTIVE UTILITY COMPANIES, AND IS THEREFORE NOT WARRANTED. PRIOR TO
CONSTRUCTION THE CONTRACTOR IS TO FIELD VERIFY ALL UTILITY LOCATIONS, SIZES, TYPE
ETC. NEEDED TO COMPLETE THE WORK OF THE CONTRACT.
THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IF A CONFLICT IS ANTICIPATED. IF THE
CONTRACTOR PROCEEDS WITHOUT CONTACTING THE UTILITY COMPANIES AND DOES NOT
NOTIFY THE ARCHITECT OF POTENTIAL CONFLICTS HE DOES SO AT HIS OWN RISK.
ANY EXISTING SANITARY SEWER PROPERTY SERVICE CONNECTIONS SHALL BE CAPPED PER
MSD SPECIFICATIONS.
AN MSD INSPECTOR MUST BE PRESENT FOR SEWER CAPS. THE CONTRACTOR MUST MAKE
SURE ALL LINES TO BE CAPPED ARE NOT LIVE LINES.
1. ANY TREE DAMAGED BY CONTRACTOR OR HIS SUBCONTRACTORS WILL BE CHARGED AT A
VALUE OF $48 PER SQUARE INCH OF TRUNK MEASURED FOUR FEET ABOVE GROUND.
2. TREE PROTECTION FENCES SHALL BE CONSTRUCTED PRIOR TO ANY EARTHWORK ON
SITE SEE DETAIL THIS SHEET. ALL EXISTING TOPSOIL / GRASS / GROUNDCOVER SHALL BE
LEFT INTACT WITHIN THE BOUNDARY OF THE TREE PROTECTION FENCE.
3. TREE PROTECTION FENCES SHALL BE MAINTAINED AND THE AREA WITHIN THE BOUNDARY
SHALL BE MOWED THROUGHOUT THE CONSTRUCTION PERIOD.
4. NO HEAVY EQUIPMENT OR TRAFFIC SHALL BE ALLOWED WITHIN THE TREE PROTECTION
FENCES AT ANY TIME.
5. IF DEMOLITION OR CONSTRUCTION IS REQUIRED WITHIN THE TREE PROTECTION FENCE
BOUNDARY, THE FENCE SHALL BE RE-INSTALLED TO MAINTAIN PROTECTION THROUGH
THE ENTIRE CONSTRUCTION PERIOD.
6. TREE PROTECTION FENCES SHALL BE REMOVED UPON COMPLETION OF THE ENTIRE
PROJECT.
7. TREE PROTECTION FENCE SHALL BE PLACED 2' OUTSIDE OF THE DRIPLINE OF THE TREE
UNLESS IMPOSSIBLE DUE TO PERMANENT OBSTRUCTION.
TREE PROTECTION NOTES LEGEND
LIMITS OF CONSTRUCTION
TREE PROTECTION FENCE
REFER TO DETAIL A / DS-100
N.T.S. A
2'- 6"
3'- 6"
8'-0" TYP. (MAX.)
CONSTRUCTION SAFETY FENCE (ORANGE IN
COLOR) ATTACH TO EA. POST W / WIRE TIES)
SITE DEMOLITION KEY
1 EXISTING PAVING AND GRAVEL SUB-BASE TO BE REMOVED COMPLETELY.
COORDINATE LIMITS WITH SITE DEVELOPMENT AND SITE UTILITY DRAWINGS.
SAW CUT TO PROVIDE CLEAN EDGE. COORDINATE EXACT LOCATIONS3
WITH SITE DEVELOPMENT AND SITE UTILITY DWGS.
EXISTING TREE OR SHRUB AND ROOT SYSTEM TO BE REMOVED COMPLETELY.
4 EXISTING CONCRETE SIDEWALK TO BE REMOVED COMPLETELY.
SCALE IN FEET
SCALE: 1" = 20'-0"
6010 20
SITE DEMOLITION PLAN
2 2 2 2 2 2
5 EXISTING UTILITY TO BE REMOVED COMPLETELY.
6 EXISTING CURB AND GUTTER TO BE REMOVED COMPLETELY.
REMOVE WALL
2 2 2 2 2 2 2 2
7 EXISTING STORM DRAINAGE SYSTEM TO BE REMOVED COMPLETELY INCLUDING BUT
NOT LIMITED TO STRUCTURES, PIPES, ETC. REFER TO GRADING AND DRAINAGE PLANS
FOR ADDITIONAL INFORMATION. STORM TO BE CAPPED AND SAFE LOADED PER MSD SPECS.
DMD
4 4
NOTE: PAVED SURFACE TO BE MAINTAINED
FOR CONSTRUCTION ENTRANCE TRAFFIC
7/2023 - 11/2023. CONTRACTOR SHALL STAGE
DEMOLITION ACCORDINGLY.
W E
S T
B R
O A
D W
A Y
SOUTH 2ND STREET
9'- 0"
TY
P.
18'-0"
TYP. 10
'-0
5'- 0"
7'- 0"
'-0
'-0
'-0
R30'-0"
24'-0"
TYP.
12'-0" 12'-0" 12'-0"
9'- 0"
TY
P.
18'-0"
TYP.
18'-0"
TYP.
9'- 0"
18'-0"
TYP.
9'- 0"
TY
P.
'-0
'-0
'-0
8'-0" 8'-0"
'-0
'-0
8'-0"
5'- 0" 5'-
0"
R3'-0"
R1 0'-
0"
R10'-0"
R3'-0"
R3'- 0"
R20'-0"
8'-0"
R10'-0"
R3'-0"
R3'-0"
R10 '-0"
R3'-0"
R10'-0"
50'-2"
R5'- 0"
'-0
6'-
1"
393'-11"
7'- 2"
R5'-0"R5'-0"
7'- 5"
MAINTAIN SMOOTH TRANSITION
BETWEEN FUTURE ASPHALT PARKING
LOT AND NEW SIDEWALK/ FIRE LANE
R3 0'-
0"
'-0
EXISTING
SIGN TO
REMAIN
EXISTING
SIGN TO
REMAIN
R20'-0"
R20'-0"
R20'-0"
R5'-0"
R15'-0"R15'-0"
6'-0" 6'-0 "
FUTURE STEEL FENCING AND GATE
BY OTHERS (N.I.C.)
RELOCATED
TRAFFIC ARMS (2)
& SUPPORT
ELECTRONICS
(SEE SHEET DS-1.0)
'-0
7'- 0"
N:275597.94 E:1208336.59
N:275205.92 E:1208276.68
70'-0"
15 '-0"
43'-0"
22'-0"
12 '-0"
'-3
36'-7" 28'-8"
43'-9"
12'-0"
24'-0"
TYP.
'-3
66'-0"
MAINTAIN SMOOTH TRANSITION
BETWEEN DRIVEWAY AND SOUTH
2ND STREET SURFACE
5'-0 " EXISTING WALK TO REMAIN
EXISTING ART INSTALLATION TO REMAIN (TYP.)
'-9
9'-
3"
5'-0"
MAINTAIN SMOOTH TRANSITION
BETWEEN FUTURE ASPHALT PARKING
LOT AND NEW SIDEWALK
10'-3"
250'-5"
33'-3"
5'- 0"
9'-0"
X P ro je c ts
\2
\2
\6 S
IT
E
\2
S
D X
.d w g
D a y
T im b
:5 p m
L o g in N a m ia z
S h e e t L a y o u t:
M
O D
E L
DRAWING NO.
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
RTA DATE
DRAWING INFORMATION
DRAWING DATE 08/07/2023
DRAWN BY
CHECKED BY
A&E FILE NO.
01/26/2024
PHASE RTA
470-CAJL-JF45 00
ACCOUNT NO.
DATEDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWING
DATEDESCRIPTION OF REVISIONS
SHERMAN CARTER BARNHART, PLLC
144 TURNER COMMONS WAY, SUITE 110
LEXINGTON, KY 40508
PHONE: 859.224.1351
FAX: 859.224.8446
DECA LOG #
AS BUILT DATE
MM/DD/YR
BKL
CONSTRUCT PARKING GARAGE /
JEFFERSON COMMUNITY AND TECHNICAL COLLEGE
WM # 10995
ADDENDUM #1 11/08/23
ADDENDUM #2 02/29/24
DMD
SCALE IN FEET
SCALE: 1" = 20'-0"
6010 20
CONCRETE WALK
F
1/4" TOOLED CONTROL JOINT (TYP.)
D
1/2" EXPANSION JOINT MATERIAL W / SEALANT (TYP.)
C
B
DETAILDESCRIPTIONKEY
A
SITE DETAILS KEY
CW / SD-3.0
CURB RAMP CR / SD-3.0
L
H CONCRETE PAVING
G
CP / SD-3.0
M
P
Q
T
S
PIPE BOLLARD BD / SD-3.0
SITE UTILITY SEE MECH/ELEC
CONCRETE WALK WITH TURNED DOWN EDGE TW / SD-3.0
DO NOT ENTER SIGN
1/4" SAWED CONTROL JOINT (TYP.)
STOP SIGN
A.D.A. TACTILE DETECTABLE WARNING SURFACE TS / SD-3.0
1. PROVIDE 1/2" EXP. JT. MATERIAL W / SEALANT WHERE NEW CONC. CURBS, WALKS, OR PAVING ABUT STORM
SEWER STRUCTURES, BUILDINGS, ETC.
2. AT END OF PROJECT, CONTRACTOR SHALL REMOVE ALL TEMPORARY FENCING, TEMPORARY EROSION
CONTROL STRUCTURES, AND OTHER TEMPORARY SERVICES ON SITE.
3. ALL RADII ARE TO BE 5' UNLESS SHOWN OTHERWISE.
4. CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL LOCAL, STATE, FEDERAL GOVERNING AGENCIES.
5. ALL PERMITS AND BONDS ARE THE RESPONSIBILITY OF THE CONTRACTOR.
6. ANY AREAS DAMAGED SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE
OWNER.
7. UTILITIES ON THIS SHEET ARE FOR REFERENCE ONLY, REFER TO UTILITY DRAWINGS FOR LOCATIONS. UNLESS
OTHERWISE SHOWN ON THIS SHEET.
8. ALL DIMENSIONS ARE TO THE FACE OF CURB UNLESS SHOWN OTHERWISE.
9. ALL TREES ARE TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE.
10. CONTRACTOR TO COORDINATE STAGING, CONSTRUCTION ENTRANCE, AND NEW WORK WITH OWNER.
11. REFER TO MECH/ELEC/PLUM SITE UTILITY SHEETS FOR ADDITIONAL CUT AND PATCHING OF PAVEMENTS.
12. REFER TO STRUCTURAL AND ARCHITECTURAL DRAWINGS FOR CONCRETE WALK CONNECTION TO BUILDING
SLAB AT DOORWAYS.
GENERAL SITE NOTES:
1. ANY TREE DAMAGED BY CONTRACTOR OR HIS SUBCONTRACTORS WILL BE CHARGED AT A
VALUE OF $48 PER SQUARE INCH OF TRUNK MEASURED FOUR FEET ABOVE GROUND.
2. TREE PROTECTION FENCES SHALL BE CONSTRUCTED PRIOR TO ANY EARTHWORK ON
SITE SEE DETAIL A\DS1.1. ALL EXISTING TOPSOIL / GRASS / GROUNDCOVER SHALL BE
LEFT INTACT WITHIN THE BOUNDARY OF THE TREE PROTECTION FENCE.
3. TREE PROTECTION FENCES SHALL BE MAINTAINED AND THE AREA WITHIN THE BOUNDARY
SHALL BE MOWED THROUGHOUT THE CONSTRUCTION PERIOD.
4. NO HEAVY EQUIPMENT OR TRAFFIC SHALL BE ALLOWED WITHIN THE TREE PROTECTION
FENCES AT ANY TIME.
5. IF DEMOLITION OR CONSTRUCTION IS REQUIRED WITHIN THE TREE PROTECTION FENCE
BOUNDARY, THE FENCE SHALL BE RE-INSTALLED TO MAINTAIN PROTECTION THROUGH
THE ENTIRE CONSTRUCTION PERIOD.
6. TREE PROTECTION FENCES SHALL BE REMOVED UPON COMPLETION OF THE ENTIRE
PROJECT.
7. TREE PROTECTION FENCE SHALL BE PLACED 2' OUTSIDE OF THE DRIPLINE OF THE TREE
UNLESS IMPOSSIBLE DUE TO PERMANENT OBSTRUCTION.
TREE PROTECTION NOTES
HEADER CURB
LEGEND
PROPERTY LINE (LIMITS OFCONSTRUCTION)
TREE PROTECTION FENCE
REFER TO DETAIL A / DS-1.0
KEY TO SHADING
LIGHT DUTY ASPHALT PAVEMENTX
W
HEAVY DUTY ASPHALT PAVEMENT
G F
CONCRETE WALK - CW / AS-2.0C
E CONCRETE CURB AND GUTTER
GENERAL PHASING NOTES:
1. IN ALL PHASES OF THIS JOB, THE CONTRACTOR MUST FULLY COOPERATE WITH THE
OWNER CLOSELY TO COORDINATE ACCESS TO THE SITE, MATERIAL STORAGE AND
STAGING AREAS, INTERRUPTIONS OF UTILITIES, MAINTENANCE OF MEANS OF
EGRESS AND SIMILAR ITEMS NECESSARY FOR THE OWNER'S SAFE OPERATION AND
USE OF PREMISES DURING CONSTRUCTION.
2. THE CONTRACTOR SHALL PROVIDE TEMPORARY UTILITIES AS REQUIRED DURING
CONSTRUCTION. SHOULD ABUSE OF TEMPORARY UTILITIES BE NOTED BY THE
OWNER AND ARCHITECT, THE GENERAL CONTRACTOR SHALL BE CHARGED
ACCORDINGLY. ADDITIONAL OFF SITE UTILITIES THAT MAY BE REQUIRED SUCH AS
PROPANE GAS OR ADDITIONAL ELECTRIC METER SERVICE SHALL BE PROVIDED BY
THE CONTRACTOR. SHOULD CONTRACTOR DISCONNECT ANY EXISTING UTILITIES
FROM A PORTION OR PORTIONS OF THE BUILDING DURING CONSTRUCTION AND
REQUIRE ADDITIONAL UTILITIES TO BE PROVIDED FOR TEMPORARY HEAT, LIGHTING,
ETC., THIS COST SHALL BE BORNE BY THE CONTRACTOR.
3. THE CONTRACTOR SHALL INSTALL TEMPORARY ENCLOSURES, DUST BARRIERS, AND
EGRESS DOORS AS REQUIRED FOR CONTROL OF SOUND, DUST AND SEPARATION
OF STUDENT POPULATION FROM CONSTRUCTION AREAS. THE CONTRACTOR SHALL
REFER TO SPECIFICATIONS FOR ADDITIONAL SAFETY MEASURES AND TEMPORARY
ENCLOSURES.
4. THE CONTRACTOR SHALL NOTIFY THE OWNER TWO (2) WEEKS PRIOR TO ANY
ANTICIPATED UTILITY OUTAGES.
5. ALL WORK TO BE COMPLETED WITHIN AREAS OF THE BUILDING THAT ARE TO
REMAIN OPEN SHALL BE COORDINATED WITH THE OWNER AND BUILDING
OCCUPANTS.
6. THE MEANS OF EGRESS MUST BE MAINTAINED FROM ALL OCCUPIED PORTIONS OF
THE FACILITY AT ALL TIMES TO THE SATISFACTION OF THE LOCAL BUILDING CODE
ENFORCEMENT OFFICIALS AND THE OWNER.
7. MINOR DEMOLITION AND RENOVATION MAY NOT OCCUR IN AN OCCUPIED AREA
DURING OPERATING HOURS, BUT MAY OCCUR AFTER HOURS AND DURING
UNOCCUPIED HOURS. SUCH WORK MUST BE SCHEDULED WITH THE OWNER A MIN.
OF (2) WEEKS IN ADVANCE .
8. INTERRUPTION OF ANY OF THE BUILDING UTILITIES MAY ONLY OCCUR AFTER
HOURS, DURING UNOCCUPIED PERIODS OR DURING HOLIDAYS OR SCHEDULED
VACATIONS. FULL SERVICE MUST BE RESTORED TO OCCUPIED AREAS OF THE
FACILITY PRIOR TO RE-OCCUPANCY.
9. NO CONDITIONS WILL BE PERMITTED WHICH, IN THE OPINION, OF THE OWNER,
CODE OFFICIAL, OR THE ARCHITECT CONSTITUTES AN UNSAFE CONDITION OR
HAZARD TO THE OCCUPANTS OR CONTINUE USE OF THE FACILITY.
10. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL SIGNAGE AND TRAFFIC
CONTROL DEVICES REQUIRED THROUGH AND AROUND THE SITE. COORDINATE
WITH THE OWNER.
11. CONTRACTOR IS RESPONSIBLE FOR KEEPING THE SITE SECURE AND SAFE AT ALL
TIMES.
12. TEMPORARY PEDESTRIAN ROUTES SHALL BE ADA ACCESSIBLE.
13. ALL EXISTING DRIVES SHALL REMAIN OPEN WHILE SCHOOL IS IN SESSION.
THE CONTRACTOR SHALL PREPARE A DETAILED SITE LOGISTICS AND PHASING PLAN
FOR OWNER APPROVAL SHOWING SCHEDULED CONSTRUCTION ACTIVITIES AND
FENCING OF AREAS TO ACHIEVE GOALS OF THIS OUTLINE LOGISTICS PLAN.
FOR ALL PEDESTRIAN ROUTES, KEEP 6' WIDE MIN. CLEAR AND OPEN PATH UNTIL SUCH TIME
THAT NEW WALKS WILL BE CONSTRUCTED. COORDINATE SCHEDULE WITH OWNER.
ROUTES SHALL INCLUDE TEMPORARY COVERS TO PROTECT FROM OVERHEAD
CONSTRUCTION, TEMPORARY WOOD DECKS, AND ADA COMPLIANT ACCESSIBLE RAMPS
(WITH LANDINGS, GUARDRAILS, AND HANDRAILS) AS NEEDED.
PEDESTRIAN ROUTE NOTES:
13. CAD FILES WILL BE AVAILABLE TO SUCCESSFUL CONTRACTOR FOR LAYOUT PURPOSES UPON CONTRACTOR SIGNING OF RELEASE FORM. ANY ADDITIONAL DIMENSIONS REQUIRED FOR LAYOUT SHALL BE REQUESTED
BY THE CONTRACTOR.
14. WHERE NEW WORK OCCURS IN EXISTING PAVEMENT, CONTRACTOR SHALL CUT AND PATCH PAVEMENT AS REQUIRED TO COMPLETE NEW WORK AND RESTORE PAVEMENT. MATCH PAVEMENT TYPE. SEE SPECIFIC DETAILS FOR NEW PAVEMENT SECTIONS. IF SPECIFIC DETAIL IS NOT INCLUDED CONTRACTOR SHALL MATCH EXISTING PAVEMENT SECTION. FOR ASPHALT PATCHING SEE DETAIL EK/AS2.0 FOR EDGE KEY. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH ALL DRAWINGS INCLUDING ALL SITE UTILITY DRAWINGS
AND ASSOCIATED UTILITY TRENCHING
15. COORDINATES SHOWN ON THIS DRAWING ARE PROVIDED TO LOCATE NEW BUILDING ON SITE. CONTRACTOR
SHALL REFER TO ARCHITECTURAL DRAWINGS FOR ACTUAL BUILDING DIMENSIONS.
SITE DEVELOPMENT PLAN
SD-1.0
U LOADING / UNLOADING SIGN LS / SD-3.0
C
G
F
F
R
C
G
F
FG
FG
C
F F
H
F
C H
U
V ACCESSIBLE PARKING SIGN AS / SD-3.0
V
V
R
F
G
C
W HEAVY DUTY ASPHALT PAVEMENT LS / SD-3.0
X LIGHT DUTY ASPHALT PAVEMENT AP / SD-3.0
W
W
W
X
XX
X
Y SPEED TABLE / RAISED CROSSWALK ST / SD-3.1
B
A
B A
P
Y R
R Y
E
E
E
E
E
E
E
C
G F
F
G
C
R PG / SD-3.0PAVEMENT APPLIED GRAPHICS
RR 4" WIDE WHITE PAINT STRIPE (TYP.) SEE SPECS.
R
R
R
R
RR
RR
TYP.
RR
NEW PARKING
STRUCTURE
C
F
G
FF
C
R
TYP.
R
TYP.
RR
TYP. RR
TYP.
RR
TYP.
D
L x 12
E
E
Z LANDSCAPE PLANTING BED / LAWN L-1.0
ZZ
Z
Z
Z
Z
Z
Z
Z
Z
Z
F
NOTE: CONCRETE FIRE LANE
SURFACE TO MATCH EXISTING
SURFACE ELEVATION OF EXISTING
ASPHALT WITH SMOOTH TRANSITION.
WHEN FUTURE GREENSPACE
PROJECT IS BUILT (NIC), FIRE LANE
WILL BE EXTENDED THROUGH THE
FUTURE PROPOSED CONCRETE
PLAZA (NIC).
Z
B B
P
SS / SD-3.0
T
HC / SD-3.0
CG / SD-3.0
D
SS / SD-3.0
Q
Q
P
C
C
AA CONCRETE WHEEL STOP WS / SD-3.0
AA
x 6
TYP.
AA
x 5
TYP.
C
C
G
D. CONCRETE PROTECTION FOR REINFORCEMENT:
1. THE MINIMUM CONCRETE COVER PROVIDED FOR REINFORCEMENT SHALL BE PROVIDED PER ACI 318, SECTION 20.6.1, U.N.O.
2. FOR CAST-IN-PLACE, POST-TENSIONED CONSTRUCTION, THE MINIMUM CONCRETE COVER FOR REINFORCEMENT
SHALL BE AS FOLLOWS:
SLAB TOP REINFORCEMENT 1 1/2"
SLAB BOTTOM REINFORCEMENT 1 1/2"
BEAM TOP REINFORCEMENT 3" OR 3X BAR DIAMETER, WHICHEVER IS GREATER
BEAM STIRRUPS AT BOTTOM AND SIDES OF BEAMS 1 1/2"
BEAM STIRRUPS AT TOP OF BEAM 2 1/2"
COLUMN TIES 1 1/2"
3. EPOXY COAT ALL REINFORCING WITHIN 2" FROM THE TOP OF P/T SLABS AND BEAMS
GENERAL NOTES
I. CODES AND STANDARDS VI. CONCRETE MASONRY
VII. STRUCTURAL STEEL
IX. GENERAL ITEMS
A. THE FOLLOWING CODES AND STANDARDS SHALL APPLY TO THE DESIGN AND CONSTRUCTION OF THIS STRUCTURE. USE THE
LATEST EDITION UNLESS NOTED OTHERWISE.
1. "INTERNATIONAL BUILDING CODE" (IBC 2015) - INTERNATIONAL CODE COUNCIL
2. "KENTUCKY BUILDING CODE" (2018) - LOCAL BUILDING CODE, AS APPLICABLE
3. "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" (ASCE 7-10) - AMERICAN SOCIETY OF CIVIL ENGINEERS
4. "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" (ACI-318-14) - AMERICAN CONCRETE INSTITUTE
5. "MANUAL OF STEEL CONSTRUCTION" (14TH EDITION) - AMERICAN INSTITUTE OF STEEL CONSTRUCTION
6. "ACI MANUAL OF CONCRETE PRACTICE" (2015, PART 1 THROUGH PART 5) - AMERICAN CONCRETE INSTITUTE
7. "CRSI DESIGN HANDBOOK" (2008) - CONCRETE REINFORCING STEEL INSTITUTE
8. "POST-TENSIONING MANUAL" (6TH EDITION) - POST-TENSIONING INSTITUTE
9. "STRUCTURAL WELDING CODE" (LASTEST EDITION) - AMERICAN WELDING SOCIETY
B. THE CONSTRUCTION OF THIS STRUCTURE INCLUDING THE QUALITY CONTROL AND SAFETY OF ALL WORK SHALL BE GOVERNED BY ALL APPLICABLE FEDERAL, COMMONWEALTH OF KENTUCKY, AND CITY OF LOUISVILLE CODES AND ORDINANCES INCLUDING FIRE
CODES. THIS STRUCTURE SHALL BE CLASSIFIED AS TYPE IB.
C. THE STRUCTURE IS DESIGNED FOR FUTURE VERTICAL EXPANSION.
D. THE STRUCTURE IS DESIGNED FOR ITS FINAL SERVICE CONDITION. G.C. & RESPECTIVE CONTRACTORS SHALL BE RESPONSIBLE FOR THE CONSTRUCTION SEQUENCE & FIELD SPLICES / CONSTRUCTION JOINTS, U.N.O. TO WITHSTAND HANDLING AND ERECTION FORCES/CONSTRUCTION LOADING, GUYING & STAYING & SHORING AS REQUIRED TO ASSURE STRUCTURAL
STABILITY DURING CONSTRUCTION STAGE.
NOTES:
1. REFER TO ASCE 7-10, FIGURE 30.6-1 FOR ADDITIONAL INFORMATION.
2. POSITIVE AND NEGATIVE PRESSURES REPRESENT PRESSURES ACTING TOWARD AND AWAY FROM THE
APPLICABLE SURFACE, RESPECTIVELY.
3. FOR ZONES INDICATED IN THE TABLE ABOVE, REFER TO THE GENERIC WALL AND ROOF SURFACE DIAGRAMS
BELOW. NOTE THAT IF A PARAPET EQUAL TO OR HIGHER THAN 3 FT IS PROVIDED AROUND THE PERIMETER OF A
ROOF SURFACE, ZONE 3 SHOULD BE TREATED AS ZONE 2.
4. MODIFY VALUES SHOWN FOR PARAPET CONDITIONS USING INTERNAL PRESSURE COEFFICIENT SHOWN ABOVE.
2 1 2
WALL SURFACE ROOF SURFACE
a a a a a = 12.5 FT a: 10% OF LEAST HORIZONTAL DIMENSION OR 0.4h, WHICHEVER IS
SMALLER, BUT NOT LESS THAN
EITHER 4% OF LEAST HORIZONTAL
DIMENSION OR 3FT.
VIII. EXAMINATION PRIOR TO CUTTING, DRILLING, AND CORING THROUGH STRUCTURE
II. EXISTING CONDITION AND CONSTRUCTION
PRIOR TO FABRICATION AND ERECTION OR INSTALLATION OF ANY MATERIAL OR PLACEMENT OF CONCRETE FOR NEW CONSTRUCTION, FIELD VERIFY ALL EXISTING ELEVATIONS, DIMENSIONS, AND CONDITIONS OF ADJACENT EXISTING CONSTRUCTION, INCLUDING FOUNDATION, AND COMPARE THEM WITH THE CONTRACT DOCUMENTS. REPORT ANY CONTRADICTION OR DISCREPANCY TO THE ARCHITECT/ENGINEER IMMEDIATELY FOR INTERPRETATIONS AND/OR ADJUSTMENTS PRIOR TO COMMENCING WORK. COST OF CORRECTION DISCREPANCIES AFTER WORK HAS BEEN STARTED SHALL BE BORNE BY THE CONTRACTOR.
III. DESIGN LOADS
A. LIVE LOADS:
1. PARKING LEVELS
A. UNIFORM LOAD 40 PSF
B. CONCENTRATED LOAD (ON 4.5" x 4.5" AREA) 3000 LBS
C. LIVE LOAD REDUCTIONS PERMITTED PER IBC SECTION 1607.11
2. STAIRS, LANDING, LOBBIES
A. UNIFORM LOAD 100 PSF
B. CONCENTRATED LOAD AT STAIR TREADS (ON 4 IN^2 AREA) 300 LBS.
3. STAIR / ELEVATOR TOWER ROOF 20 PSF
4. BUMPER IMPACT LOAD ON 18" & 27" A.F.F. (ON 1 SQ. FT. SURFACE) 6000 LBS.
5. ELEVATOR MACHINE ROOM PER MANUFACTURER'S PRODUCT INFO.
NOTE: CONCENTRATED LOADS APPLIED TO PRODUCE MAXIMUM STRESS ON ALL SUSCEPTIBLE MEMBERS.
B. SUPERIMPOSED DEAD LOADS:
1. MECHANICAL AND ELECTRICAL COMPONENTS 5 PSF
2. BUILDING FACADE COMPONENTS PER ARCHITECTURAL PLANS
C. WIND LOADS:
1. BASIC DESIGN WIND SPEED 115 MPH
2. RISK CATEGORY II
3. WIND EXPOSURE B
4. INTERNAL PRESSURE COEFFIECIENT, GCpi +/- 0.18
5. COMPONENTS & CLADDING WIND DESIGN PRESSURE, Ps SEE TABLE BELOW
D. SEISMIC LOADS:
1. SEISMIC IMPORTANCE FACTOR, Ie 1.00
2. OCCUPANCY RISK CATEGORY II
3. Ss: 0.2 SECOND SPECTRAL RESPONSE ACCELERATION 0.198% g S1: 1.0 SECOND SPECTRAL RESPONSE ACCELERATION 0.099% g
4. SITE CLASS D
5. SDS: 0.2 SECOND SPECTRAL RESPONSE COEFFICIENT 0.211% g SD1: 1.0 SECOND SPECTRAL RESPONSE COEFFICIENT 0.159% g
6. SEISMIC DESIGN CATEGORY C
7. (BASIC) SEISMIC FORCE RESISTING SYSTEM
A. THE SEISMIC FORCE RESISTING SYSTEM SHALL BE CLASSIFIED AS ORDINARY REINFORCED CONCRETE MOMENT FRAMES
AND SHALL COMPLY WITH THE REQUIREMENTS OF ASCE 7-10 SECTION 14.2.
B. MOMENT-RESISTING FRAME SYSTEM WITH ORDINARY REINFORCED CONCRETE MOMENT FRAMES.
i. RESPONSE MODIFICATION FACTOR, R 3
ii. DEFLECTIONS MODIFICATION FACTOR, CD 2.5
8. Cs: SEISMIC RESPONSE COEFFICIENT
A. N-S DIRECTION Cs = 0.071 B. E-W DIRECTION Cs = 0.071
9. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE PROCEDURE
10. DESIGN BASE SHEAR
A. N-S DIRECTION SEISMIC LOADS Vs = 1160 KIPS B. E-W DIRECTION SEISMIC LOADS Vs = 1160 KIPS
E. SNOW LOADS:
1. GROUND SNOW LOAD, pg 15 PSF
2. SNOW EXPOSURE FACTOR, Ce 1.0
3. THERMAL FACTOR, Ct 1.2
4. SNOW IMPORTANCE FACTOR, Is 1.0
5. FLAT ROOF SNOW LOAD, pf 11.8 PSF
F. RAIN LOADS:
1. DEPTH OF WATER UP TO SECONDARY DRAINAGE SYSTEM, ds 3"
2. ADD'L DEPTH OF WATER ABOVE SECONDARY DRAINAGE SYSTEM, dH 0"
3. RAIN LOAD, R 15 PSF
G. VOLUME CHANGE PARAMETERS:
1. DESIGN TEMPERATURE DIFFERENTIAL 58 °F
2. ANNUAL AVERAGE AMBIENT RELATIVE HUMIDITY 71 %
3. CONSIDER MINIMUM 50% ADDITIONAL VOLUME CHANGE EFFECTS DUE TO P/T STRESSING ON UPPER LEVELS FOR FINAL
EXPANSION JOINT SIZES. PRIOR TO SUBMITTAL OF EXPANSION JOINT SHOP DRAWING, CONTRACTOR SHALL FIELD VERIFY THE
AS-BUILT GAPS BETWEEN STAIR TOWER & PARKING STRUCTURES & TEMPERATURES AT SITE.
A. THE FOUNDATION (INCLUDING AUGER CAST PILES, PILE CAPS, GRADE BEAMS, AND SLAB-ON-GRADE) HAS BEEN DESIGNED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT PREPARED BY CONSULTING SERVICES INCORPORATED DATED FEBRUARY 13, 2023.
SEE DIVISION 31 OF THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
B. FOUNDATION DESIGN PARAMETERS
1. AUGER CAST PILE (18" PILE DIAMETER) @ 75FT PILE LENGTH
A. ALLOWABLE AXIAL CAPACITY 302 KIPS (151 TONS)
B. ALLOWABLE UPLIFT CAPACITY 252 KIPS (126 TONS)
C. ALLOWABLE LATERAL CAPACITY TO BE DETERMINED BY GEOTECHNICAL ENGINEER
3. FROST DEPTH 2 FT
C. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF ALL TEMPORARY EXCAVATIONS, BRACING, SHEETING, AND SHORING.
IV. FOUNDATION WORK
A. MATERIAL PROPERTIES - CONCRETE
MIN. f'c AT MAX. W/C MAX TOTAL AIR
28 DAYS RATIO SLUMP CONTENT
(PSI) (INCHES)
1. CAST-IN-PLACE CONCRETE:
PILES 5000 N/A N/A NOT REQ'D
FOUNDATION (PILE CAPS, G.B.) 5000 0.45 4 NOT REQ'D
WALLS, PIERS 5000 0.40 4 5 1/2±1 1/2%
COLUMNS 6000 0.40 3 6 1/2±1 1/2%
SLAB-ON-GRADE 5000 0.40 3 6 1/2±1 1/2%
P/T BEAMS, GIRDERS, SLAB, 5000 0.40 3 6 1/2±1 1/2%
STAIR/ELEVATOR TOWER
WALLS, BUMPER WALLS, &
STAIRS
2. OTHER CONCRETE:
DRY PACK / GROUT 3000 N/A 8-10 NOT REQ'D
MASONRY GROUT FILL
N.S.N.S GROUT 6000 N/A 0 NOT REQ'D
3. THE ALLOWABLE MAXIMUM SLUMP SHOWN ABOVE SHALL BE PRIOR TO ADDING SUPER-PLASTICIZER AS APPLICABLE. THE ALLOWABLE MAXIMUM SLUMP OF CONCRETE MIXES AFTER SUPER-PLASTICIZER ADMIXTURE IS ADDED SHALL BE 8" ± 1 1/2".
4. ALL CONCRETE AGGREGATES SHALL BE NORMAL -WEIGHT, U.N.O.
B. MATERIAL PROPERTIES - REINFORCING & CONNECTION STEEL:
TYPE GRADE, KSI ASTM REF.
DEFORMED REBARS, U.N.O. 60, 80 A615 (A706)
WELDABLE DEFORMED REBARS 60, 80 A706
WELDED WIRE REINFORCEMENT (W.W.R.) 65 A185
POST-TENSION STRANDS 270 A416
DEFORMED BAR ANCHORS (D.B.A.) 79 A469
HEADED ANCHOR STUDS (H.A.S.) 60 A108
C. CAST-IN-PLACE CONCRETE NOTES:
1. THE MINIMUM CONCRETE COVER PROVIDED FOR REINFORCEMENT SHALL BE PROVIDED PER ACI 318-14, SECTION 20.6, U.N.O. REFER TO THE TABLE BELOW FOR THE REQUIRED CONCRETE COVERS FOR NON-PRESTRESSED, C.I.P. CONCRETE, TYP.
2. ALL REINFORCEMENT SHALL BE CONTINUOUS AND NO SPLICES SHALL BE PERMITTED EXCEPT AS DETAILED OR AUTHORIZED BY THE ENGINEER. WHEN PERMITTED, COLUMN REINFORCEMENT TO BE SPLICED ACCORDING TO ACI 318, SECTION 25.5, U.N.O.
3. TENSION SPLICES SHALL BE MADE BY CLASS B LAP SPLICES, TYPICAL, U.N.O.
4. PROVIDE ADDITIONAL REINFORCEMENT AROUND ALL OPENINGS, I.E., DOORS, WINDOWS, BLOCKOUTS, ETC., AS FOLLOWS:
(2) #5 BARS ON ALL SIDES OF EACH OPENING EXTENDED 2'-0" BEYOND THE CORNERS OF EACH OPENING PLUS (2) #5 BY
4'-0" LONG DIAGONALS AT EACH CORNER EXCEPT AS NOTED HEREIN.
5. PROVIDE 3/4" CHAMFERS ON EXPOSED CORNERS OF CONCRETE, U.N.O.
6. PROVIDED CONSTRUCTION AND CONTROL JOINTS IN SLABS AND WALLS AS SHOWN ON THE DRAWINGS. FOR FURTHER
INFOMRATION, REFER TO SECTION 033000 OF THE SPECIFICATIONS.
7. ALL INSERTS, COIL RODS, AND PLATE CONNECTIONS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. WHENEVER FEASIBLE, ALL INSERTS AND SLEEVES SHALL BE CAST IN THE CONCRETE. USE OF POWER-PROPELLED FASTENERS OR DRILLED-IN ANCHORS SHALL NOT BE ALLOWED IN PRESTRESSED CONCRETE UNLESS AUTHORIZED IN WRITING BY THE
ENGINEER.
8. PROVIDE A MINIMUM OF ONE INCH CLEARANCE GAP BETWEEN BACKUP BARS FOR P/T ANCHORS AND ANCHOR PLATE.
9. STRESSING SEQUENCE FOR POST-TENSIONING SHALL BE AS FOLLOWS:
• SLAB TENDONS PARALLEL TO BEAMS
• SLAB TENDONS PERPENDICULAR TO BEAMS
• BEAM TENDONS
• GIRDER TENDONS
DO NOT CHANGE THE ORDER OF SEQUENCING, STRESS P/T MEMBERS WITHIN 96 HOURS AFTER CONCRETE POUR. THE MINIMUM COMPRESSIVE CONCRETE STRENGTH FOR THE STRESSING IS 3000 PSI. SEE SECTION 033650 OF THE
SPECIFICATIONS FOR ADDITIONAL INFORMATION ON STRESSING.
9. DO NOT BUNDLE MORE THAN THREE SLAB TENDONS IN A SINGLE BUNDLE WITHOUT PRIOR WRITTEN PERMISSION FROM
THE ENGINEER.
10. ALL C.I.P. SLABS, BEAMS, GIRDERS, AND STAIRS TO CONTAIN CALCIUM NITRITE CORROSION INHIBITOR (3 GAL. PER CU.
YD. OR CONCRETE) AND 1 1/2 LB. FIBROUS REINFORCEMENT PER CUBIC YARD OF CONCRETE IN ACCORDANCE WITH SPEC.
SECTION 033000. MAXIMUM SIZE OF COARSE AGGREGATE SHALL BE 3/4" TYP., U.N.O.
11. MAXIMUM SIZE OF COARSE AGGREGATE IN CONJESTED REINFORCING AREAS AND AT BEAM/COLUMN INTERFACES SHALL
BE 3/8" TYP.
12. SLAB-ON-GRADE TO CONTAIN 1 1/2 LB. FIBROUS REINFORCEMENT PER CU. YD. OF CONCRETE IN ACCORDANCE WITH
SPECIFICATION SECTION 033000. MAXIMUM SIZE OF COARSE AGGREGATE SHALL BE 3/4".
V. CONCRETE
A. MATERIAL PROPERTIES - MASONRY
1. NET AREA COMPRESSIVE STRENGTH OF MASONRY SYSTEM, f'M=1900 PSI
2. MORTAR TYPE "M" (BELOW GRADE) OR "S" (ABOVE GRADE)
B. GENERAL NOTES FOR MASONRY
1. MINIMUM VERTICAL REINFORCEMENT FOR MASONRY WALLS SHALL BE #4 @ 48" O.C., TYPICAL, U.N.O. PROVIDE ONE #5 VERTICAL AT ALL CORNERS, AT EACH SIDE OF OPENINGS AND AT ENDS OF WALLS. MASONRY WALLS SUBJECT TO BUMPER LOADS SHALL BE REINFORCED WITH #4 @ 16" O.C. EXTENEDED TO AT LEAST 2'-8" ABOVE
FLOOR, AND ALL CORES SHALL BE GROUTED SOLID UP TO 2'-8" ABOVE FLOOR.
2. PROVIDE DOWELS BETWEEN FOUNDATION AND MASONRY WALLS TO MATCH VERTICAL WALL REINFORCEMENT IN
SIZE AND SPACING, U.N.O.
3. HORIZONTAL JOINT REINFORCEMENT FOR MASONRY WALLS SHALL BE STANDARD WEIGHT, GALVANIZED, AND SPACED @ 16" O.C., TYPICAL, U.N.O. PROVIDE ONE-PIECE PREFABRICATED UNITS SPACED @ 8" O.C. AT WALL
CORNERS AND INTERSECTIONS.
4. MINIMUM BOND BEAM REQUIREMENTS, U.N.O. - PROVIDE CONTINUOUS HORIZONTAL BOND BEAM WITH (2) #5
CONTINUOUS BARS AT THE FOLLOWING LOCATIONS:
A. ABOVE DOOR OPENINGS
B. AT TOP OF WALL PER "TYPICAL TOP OF C.M.U. WALL DETAIL"
C. A MAXIMUM OF 8'-0" ABOVE THE FLOOR AND SPACED VERTICALLY AT 8'-0" O.C. (MAX) THEREAFTER
D. PER APPLICABLE BUILDING CODE REQUIREMENTS
5. PROVIDE BOND BEAM LINTELS WITH TWO #5 CONTINUOUS BARS ABOVE OPENINGS, U.N.O. LENGTH OF BEARING SUPPORT FOR BOND BEAMS SHALL BE 1" PER FOOT OF OPENING BUT NOT LESS THAN 8" AND BEARING SUPPORT SHALL BE SOLID BLOCKS OR HOLLOW BLOCKS GROUTED SOLID, OVER THREE COURSES BELOW AND EXTENDING
OUT AT THE ANGLE OF 45 DEGREES, U.N.O.
6. THE CONTRACTOR SHALL VERIFY THAT ALL OPENINGS BELOW LINTELS ARE ADEQUATE TO ACCEPT DOOR OR WINDOW FRAMES, LOUVERS, ETC., AS SHOWN ON THE DRAWINGS. NOTIFY ARCHITECT AND/OR ENGINEER OF
ANY CONFLICT PRIOR TO LINTEL INSTALLATION
7. PROVIDE CONTROL JOINTS IN MASONRY OR BRICK WALLS AT 20'-0" O.C. MAXIMUM, U.N.O.
8. FOR CONTINUOUS BOND BEAMS, PROVIDE HORIZONTAL REINFORCING AT WALL CORNERS AND INTERSECTIONS
PER C.I.P. WALL "CORNER REINFORCING DETAIL", SIM.
A. MATERIAL PROPERTIES - STRUCTURAL STEEL
Fy, PSI ASTM REF. (U.N.O.)
W-SHAPES 50,000 A992
ANCHOR BOLTS 36,000 F1554, GRADE 36
CONNECTION STEEL 36,000 A36
STEEL PIPES 35,000 A53, GRADE B
STRUCTURAL TUBES 46,000 A500, GRADE B
COLD FORMED STEEL 33,000 A924
WELDING ELECTRODES E70XX AWS D1.1, D1.6 OR D19.0
TYPE Fu, PSI ASTM REF.
HIGH STRENGTH BOLTS 120,000 A325
B. STRUCTURAL STEEL FABRICATION, ERECTION AND CONNECTION DESIGN SHALL CONFORM TO AISC "MANUAL OF
STEEL CONSTRUCTION".
C. ALL STRUCTURAL STEEL CONNECTIONS SHALL BE PERFORMANCE DESIGNED (INCLUDING FIELD SPLICE CONNECTIONS) TO RESIST THE DESIGN LOADS. SUBMIT CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER, REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED, FOR APPROVAL PRIOR TO ANY FABRICATION.
D. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO ANY FABRICATION.
E. MEMBER CONNECTIONS SHALL BE DETAILED FOR A MINIMUM FACTORED FORCE OF NO LESS THAN 10 KIPS AS PER
AISC "MANUAL OF STEEL CONSTRUCTION".
F. ALL CONNECTIONS SHALL BE STANDARD AISC FRAMED OR SEATED BEAM CONNECTIONS, U.N.O.
G. ALL EXTERIOR STEEL MEMBERS AND CONNECTIONS SHALL BE PAINTED WITH RUST-INHIBITING PRIMER OR HOT-DIP GALVANIZED AND PAINTED PER SPECIFICATIONS. DO NOT GALVANIZE OR PAINT SURFACES TO BE FIELD WELDED.
TOUCH UP ALL FIELD WELDS WITH RUST-INHIBITING PRIMER OR GALVANIZING REPAIR PAINT AND PAINT PER
SPECIFICATIONS. REFER TO AWS D19.0 FOR ADDITIONAL INFO.
H. BOLTED CONNECTIONS:
1. ALL BOLTED CONNECTIONS SHALL BE MADE WITH 3/4" ⌀ ASTM A325 BOLTS WITH ASTM F436 WASHERS AND ASTM
A563 NUTS, U.N.O.
2. ALL HIGH-STRENGTH BOLT CONNECTIONS SHALL CONFORM TO "SPECIFICATIONS FOR STRUCTURAL JOINTS
USING ASTM A325 BOLTS" AS ENDORSED BY AISC.
3. HIGH-STRENGTH BOLTED CONNECTION SHALL BE BEARING TYPE WITH THREADS ALLOWED IN THE SHEAR PLANE, U.N.O.
4. HIGH-STRENGTH BOLTS SHALL BE SNUG-TIGHTENED, UNLESS REQUIRED BY AISC "MANUAL OF STEEL CONSTRUCTION" TO BE FULLY PRETENSIONED OR NOTED AS PRETENSIONED ON THE DRAWINGS. PRETENSION
BOLTS WITH A CALIBRATED TORGUE WRENCH OR BY THE "TURN OF THE NUT" METHOD.
I. ALL WELDING SHALL CONFORM TO THE LATEST EDITION OF AWS D1.1, AWS D1.6 (STAINLESS STEEL), OR AWS D19.0
(GALVANIZED STEEL), AS APPLICABLE.
J. WELDED CONNECTIONS:
1. MINIMUM SIZE OF WELD SHALL BE 3/16", U.N.O.
2. SURFACE TO BE FIELD WELDED SHALL BE CLEAN AND FREE OF PAINT, DIRT, GREASE OR OTHER FOREIGN
MATERIALS.
A. DO NOT CUT, DRILL, OR CORE THROUGH ANY STRUCTURAL ELEMENT WITHOUT PRIOR WRITTEN APPROVAL FROM
THE ENGINEER, U.N.O.
B. THE CONTRACTOR SHALL SCAN THE CONCRETE AT ALL LOCATIONS OF PROPOSED CUTS AND PENETRATIONS TO LOCATE AND MARK ALL EMBEDDED OBJECTS INCLUDING BUT NOT LIMITED TO EMMEDDED REINFORCING, POST- TENSION STRANDS, EMBEDDED CONNECTOINS, ELECTRICAL CONDUIT, AND ANY OTHER EMBEDDED HARDWARE/EQUIPMENT. SCANNING SHALL BE PERFORMED BY A CERTIFIED TECHNICIAN USING A PACHOMETER OR GROUND PENETRATING RADAR (GPR) TYPE SCANNER. CALIBRATE THE SCANNER AT THE BEGINNING OF EACH SHIFT AND WHEN CONDITIONS CHANGE. LOCATED AT LEAST THREE REINFORCING BARS USING THE SCANNER, AND HAMMER DRILL TEST HOLES TO DETERMINE DEPTH OF COVER. CALIBRATE SCANNER USING THE DEPTH OF COVER
MEASUREMENTS.
C. ADJUST LOCATIONS OF CUTS AND PENETRATIONS AS REQUIRED TO AVOID EMBEDDED OBJECTS.
D. SUBMIT SCANNING REPORTS(S), INCLUDING PHOTOGRAPHS AND SCALED DRAWINGS AND/OR SKETCHES, TO ARCHITECT/ENGINEER FOR APPROVAL. ALLOW SEVEN DAYS FOR ARCHITECT/ENGINEER TO REVIEW AND APPROVE OR COMMENTS ON THE PROPOSED CUTS AND PENETRATIONS. ADJUST THE LOCATIONS AS DIRECTED BY THE
ARCHITECT/ENGINEER.
E. USE HAMMER DRILLS WHEN POSSIBLE; DO NOT CORE DRILL UNLESS THE SCANNING OPERATION HAS CLEARLY
SHOWN THAT THE ARE IS FREE OF EMBEDDED OBJECTS.
F. DO NOT CUT THROUGH OR DAMAGE THE EMBEDDED REINFORCING, POST-TENSION STRANDS, EMBEDDED
CONNECTIONS, ELECTRICAL CONDUIT, AND ANY OTHER EMBEDDED HARDWARE/EQUIPMENT.
A. THE NOTES ON THIS SHEET SUPPLEMENT THE SPECIFICATIONS, WHICH SHALL BE REFERRED TO FOR FURTHER
INFORMATION.
B. IN CASE OF CONFLICT BETWEEN NOTES, DETAILS AND SPECIFICATIONS, THE MOST STRINGENT REQUIREMENTS
SHALL GOVERN.
C. FOR EXACT SIZES AND LOCATIONS OF ALL MECHANICAL, PLUMBING AND ELECTRICAL ITEMS AND PENETRATIONS, CONSULT RESPECTIVE TRADES FOR COORDINATION.
D. DO NOT SCALE THE DRAWINGS.
COMPONENTS & CLADDING WIND PRESSURES BASED ON LOCATION AND
COMPONENT EFFECTIVE WIND AREA, A (PSF)
LOCATION
A ≤ 50 FT2 50 FT2< A < 500 FT2 500 FT2≤ A
POSITIVE
ZONE 1
ZONE 2
ZONE 3
ZONE 4
< TIER 3
TIER 4
ZONE 5
< TIER 3
TIER 4
16.00
23.77
25.71
23.77
25.71
POSITIVE POSITIVE NEGATIVENEGATIVENEGATIVE
-25.71
-43.13
-64.92
-25.78
-27.88
-31.83
-34.42
16.00
21.76
23.53
21.76
23.53
-24.83
-29.81
-38.78
-42.29
-45.59
-46.38
-50.00
16.00
17.73
19.17
-23.53
-27.88
-27.88
-19.74
-21.35
16.00
16.00
16.00 16.00
16.00 16.00
17.73
19.17
-19.74
-21.35
X. ABBREVIATIONS
A.B. ANCHOR BOLT
A.F.F. ABOVE FINISHED FLOOR
ALT. ALTERNATE
ARCH. ARCHITECT
BET. BETWEEN
BIT. BITUMINOUS
BOT. BOTTOM
BRG. BEARING
C.I.P. CAST-IN-PLACE
C.J. CONTROL JOINT/ CONSTRUCTION JOINT
CL./CLR. CLEAR
C.M. CONSTRUCTION MANAGER
C.M.U. CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONT. CONTINUOUS
CONTR. CONTRACTOR
D.B.A. DEFORMED BAR ANCHOR
DET. DETAIL
DIA./ DIAMETER
DIM. DIMENSION
DN. DOWN
DWG(S). DRAWING(S)
EA. EACH
E.B.F. ELEVATION BOTTOM OF FOOTING
E.B.P. ELEVATION BOTTOM OF PIER
E.F. EACH FACE
E.F.G. ELEVATION FINISHED GRADE
E.J. EXPANSION JOINT
EL./ELEV. ELEVATION
ELEC. ELECTRICAL
EQ. EQUAL
E.T.B. ELEVATION TOP OF BEAM
E.T.P. ELEVATION TOP OF PILE OR DRILLED PIER CAP
E.T.F. ELEVATION TOP OF FOOTING
E.T.L. ELEVATION TOP OF LEDGE
E.T.P. ELEVATION TOP OF PIER
E.T.P/C. ELEVATION TOP OF PRECAST
E.T.S. ELEVATION TOP OF STEEL
E.T.W. ELEVATION TOP OF WALL
E.W. EACH WAY
E.W.E.F. EACH WAY, EACH FACE
E.W.P. ELEVATION WORKING POINT
EXT. EXTERIOR
F.D. FLOOR DRAIN
F.E. FIRE EXTINGUISHER
F.F. FAR FACE / FINISH FLOOR
FDN. FOUNDATION
FIN. FINISH
FL./FLR. FLOOR
FTG. FOOTING
GA. GAUGE
GALV. GALVANIZED
G.B. GRADE BEAM
G.C. GENERAL CONTRACTOR
GR. GRADE
G.W.B. GYPSUM WALL BOARD
H.A.S. HEADED ANCHOR STUDS
H.D.G. HOT-DIP GALVANIZED
H.M. HOLLOW METAL
HOR. HORIZONTAL
HT. HEIGHT
H.V.A.C. HEATING, VENTILATION & AIR CONDITIONING
I.D. INSIDE DIAMETER
INFO. INFORMATION
INSUL. INSULATION
INT. INTERIOR
INV. INVERT
IT INVERTED TEE
JT. JOINT
LBS. POUNDS
LIN. LINEAL
L.L.V. LONG LEG VERTICAL
MAX. MAXIMUM
MECH. MECHANICAL
MANUF. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
MTL. METAL
N.F. NEAR FACE
N.I.C. NOT IN CONTRACT
N.S.N.S. NON-SHRINK, NON-STAIN
N.T.S. NOT TO SCALE
O.C., O/C ON CENTER
O.D. OUTSIDE DIAMETER
O.H. OPPOSITE HAND
P/C PRECAST CONCRETE
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
P/T POST-TENSIONED
R.D. ROOF DRAIN
RM. ROOM
R.O. ROUGH OPENING
R.O.F. RANDOM ORIENTED FIBER
SCHED. SCHEDULE
SECT. SECTION
SHT. SHEET
SIM. SIMILAR
S.L.V. SHORT LEG VERTICAL
S.0.G. SLAB-ON-GRADE
SPEC(S). SPECIFICATION(S)
SQ. SQUARE
STD. STANDARD
STL. STEEL
T.&.B. TOP AND BOTTOM
T.B.D. TO BE DETERMINED
TYP. TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
W/ WITH
W/O WITHOUT
W.P. WORKING POINT
WT. WEIGHT
W.W.R. WELDED WIRE REINFORCEMENT
Concrete Exposure Member Reinforcement Specified cover, in.
Cast against and permanently in contact with ground
Exposed to weather or in contact with ground
Not exposed to weather or in contact with ground
All
All
Slabs, joists, and walls
Beams, columns, pedestals, and tension ties
All
No. 6 through No.
18 bars
No. 5 bar, W31 or D31 wire, and smaller
No. 14 and No. 18 bars
No. 11 bars and smaller
Primary reinforcement, stirrups, ties, spirals, and hoops
1-1/2
1-1/2
3/4
1-1/2
TABLE 20.6.1.3.1 - SPECIFIED CONCRETE COVER FOR
CAST-IN-PLACE NON-PRESTRESSED CONCRETE MEMBERS
a a a a θ h
5 5
08/28/2023RTA DATE
DECA LOG #
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING DATE
DRAWING NO.
AS BUILT DATE
MM/DD/YR
PHASE RTA FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
ACCOUNT NO.
470 CAJLJF45 00
CONSTRUCT PARKING GARAGE
JEFFERSON COMMUNITY AND TECHNICAL COLLEGE
SHERMAN CARTER BARNHART, PLLC
144 TURNER COMMONS WAY, SUITE 110
LEXINGTON, KY 40508
PHONE: 859.224.1351
FAX: 859.224.8446
DATEDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWING
DATEDESCRIPTION OF REVISIONS
DRAWING INFORMATION
/1
/2
:5
:5
P M
S0.1
GENERAL NOTES01/26/2024
A T
L .0
J C
T C
P A
R K
IN
G
D E
C K
ATL22127.00
DC
KWC
THA Consulting, Inc.
410 Peachtree Parkway Cumming, GA 30041 T. 770.850.3065 www.tha-consulting.com
ADDENDA #2 03/01/24
1 3 5 6 7
B
A
C
8 9 10 11 12 14 15 17162 4 13
1'-0" 27'-4" 21'-2" 27'-0" 27'-0" 27'-0" 27'-0" 27'-0" 27'-0" 27'-0" 27'-0" 25'-11" 2'-2" 25'-11" 27'-0" 21'-2" 27'-4" 1'-0"
1' -0
'-6
'-6
1'
-0
395'-0"
5'
-0
PC-5
-(3 '-2
PC-4
PC-5 -(3'-2")
PC-5 -(3'-2")
PC-5 -(3'-2")
'-6
PC-3
-(2 '-0
PC-6
PC-5 -(2'-6")
PC-3 -(7'-0")
PC-3 -(7'-0")
PC-3 -(7'-0")
PC-3 -(7'-0")
PC-3 -(7'-0")
PC-3 -(7'-0")
PC-6 -(4'-0")
PC-3 -(4'-0")
PC-3 -(4'-0")
PC-3 -(7'-0")
PC-3 -(7'-0")
PC-3 -(7'-0")
PC-3 -(4'-0")
PC-3 -(4'-0")
PC-1
(4
'-0
PC-1
(2
'-6
A.2
B.8
GB1
(2 '-6
GB1
(2 '-0
GB1
(2 '-0
GB1
(2 '-0
GB1
(5 '-0
PC-1
-(5 '-0
GB1
(5 '-0
GB1
(2 '-0
GB1
(3 '-6
GB1
(4 '-0
T Y
P
3'
0"
T Y
P
6'
" 3'
- 8
TYP.
5' - 2"
2'
2'
2' - 3"
2' - 3"
5' - 2"
S2.2
TYP.
GB2
(7 '-0
GB1 -(7'-0")
GB1 -(7'-0")
GB2 -(7'-0")
GB1 -(4'-0")
GB1 -(4'-0")
GB1 -(4'-0")
GB1 -(4'-0")
GB1 -(4'-0")
GB2 -(7'-0")
GB2 -(7'-0")
GB2 -(7'-0")
GB2
(3 '-2
GB2
(3 '-2
GB2
(3 '-2
GB2
(3 '-2
GB2
(3 '-2
GB2
(3 '-2
GB2
(3 '-2
W F1
-(4 '-0
W
F1 -(3
'-2
PC-6 -(3'-2")
S2.1
GB1
(2 '-6
GB2 -(2'-6")
PC-3 -(3'-0")
T Y
P
3'
0"
T Y
P
3'
0"
6'
GB1
(2 '-6
GB1
(2 '-0
GB1
(2 '-0
GB1
(2 '-0
GB1
(2 '-0
GB1
(3 '-0
5"
GB1
(2 '-6
")3"
GB2 -(7'-0")
GB2 -(7'-0")
GB2 -(7'-0")
GB2 -(4'-0")
STEP
GB1
(2 '-0
STEP
STEP
STEP
GB1
(4 '-9
GB1
(7 '-0
8'
13' - 4"
STEP
13' - 6"
GB1
(2 '-0
13' - 6"
GB2
(3 '-2
STEP
W F1
(3
'-2
W F1
(7
'-0
STEP
GB2
(3 '-2
STEP
E.T.W. = +(6'-9")
E.T.W. = +(7'-11")
Fx = 6 kips Fy = 4 kips Fz = 124 kips
Fx = 6 kips Fy = 4 kips Fz = 124 kips
Fx = 6 kips Fy = 4 kips Fz = 124 kips
Fx = 6 kips Fy = 4 kips Fz = 124 kips
Fx = 6 kips Fy = 4 kips Fz = 124 kips
Fx = 6 kips Fy = 4 kips Fz = 124 kips
Fx = 6 kips Fy = 4 kips Fz = 124 kips
Fx = 6 kips Fy = 4 kips Fz = 124 kips
Fx = 28 kips Fy = 18 kips Fz = 196 kips
Fx = 6 kips Fy = 4 kips Fz = 160 kips
Fx = 2 kips Fy = 2 kips Fz = 128 kips
Fx = 6 kips Fy = 4 kips Fz = 280 kips
ELEVATOR SHAFT WALLS:
Fx = 180 kips Fy = 110 kips Fz = 1160 kips
SHEET NOTES:
1. REFER TO SHEET S0.1 FOR GENERAL NOTES.
2. REFER TO SHEET S0.3 FOR GENERAL DETAILS.
3. REFER TO SHEET S1.1 FOR GROUND TIER PLAN, WITH FOUNDATION DETAIL
REFERENCES.
4. REFER TO SHEETS S1.0 & S2.1 THROUGH S2.2 FOR FOUNDATION DETAILS.
5. REFER TO SHEET S2.1 FOR E.T.W. (C.I.P. WALLS) NOT SHOWN ON PLAN.
6. REFER TO THIS SHEET FOR PILE CAP SCHEDULE.
7. ALL PILE CAPS AND COLUMNS ARE CENTERED ON GRID LINES U.N.O.
8. USE 75'-0" PILE LENGTH FOR ESTIMATING AND BIDDING PURPOSES ONLY. FRICTION
PILES TO BE PROVIDED AND REVIEWED IN THE FIELD BY GEOTECHNICAL ENGINEER
BASED ON ACTUAL CONDITIONS ENCOUNTERED.
9. TOP OF CONTINUOUS GRADE BEAMS TO MATCH E.T.C. OF ADJACENT PILE CAPS, U.N.O.
10. STEP WALL FOOTINGS AT LOCATIONS SHOWN ON PLAN PER DETAIL 5/S2.1.
11. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION
OF ALL TEMPORARY EXCAVATIONS, BRACING, SHEETING, AND SHORING.
12. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEWATERING ANY
GROUNDWATER ENCOUNTERED DURING EXCAVATION.
13. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING EXISTING
UTILITIES WITHIN THE NEW FOUNDATION LOCATIONS.
14. BASE EL. REPRESENTS THE BENCH MARK BY WHICH ACTUAL ELEVATIONS ARE
CALCULATED BY ADDING OR SUBTRACTING ELEVATIONS SHOWN ON THE SPECIFIC
LOCATION OF FOUNDATIONS.
C.I.P. FOUNDATION/WALL CONSTRUCTION TOLERANCE NOTE:
1. ALL C.I.P. CONSTRUCTION SHALL MEET REQUIRED TOLERANCES PER ACI 117, U.N.
2. ALL C.I.P. WALLS/FOUNDATIONS, WHICH WILL SUPPORT PRECAST MEMBERS ABOVE,
SHALL BE CONSTRUCTED TO MEET PRECAST CONCRETE TOLERANCE REQUIREMENTS
PER ACI 117 & PCI MANUAL 116, 120, 127.
X
X
PILE CAP MARK,
SEE SCHEDULE
PCx (E
.T .C
GBx (E
.T .B
ELEVATION TOP OF
GRADE BEAM (E.T.B.)
GRADE BEAM MARK PILE CAP
C.I.P. COLUMN ABOVE
ELEVATION TOP
OF PILE CAP
PILE, TYP.
PILE LEGEND
COMPRESSION/LATERAL PILE
TENSION PILE
SECTION B-B
18" DIA. AUGER-PLACED
GROUTED PILES
B
PILE CAP REINF.
(SEE PILE CAP SCHED.)
COL. DOWEL BAR TO
MATCH VERT. IN SIZE
& QUANTITY, TYP.
C.I.P. COLUMN, SEE SCHEDULE
ON S3.1 FOR ADD'L INFO.
18" DIA. A.C.I.P. PILE
X
COMPRESSION PILE
SECTION A-A
18" DIA. A.C.I.P. PILE
TENSION/LATERAL PILE
A A
CONTRACTOR TO FULLY
PERFORMANCE DESIGN.
EXTEND VERT. REINF. TO
PROJECT INTO PILE CAP
AS SHOWN, TYP.
#14 FULL LENGTH
CENTER BAR; Fy= 75 KSI
S E
E S
C H
E D
U
LE
T E
N S
IO
N
S P
LI
C
E
C
LA
S S
'B
4" 3"
NOTES:
1. REQUIRED GROUT STRENGTH OF 5000 PSI IS FOR A 28-DAY TEST.
COVER, TYP.
3" (MIN.) CLR
3" C
LR
FULL LENGTH #14 DYWIDAG THREADED
BAR W/ DOUBLE HEX NUT & WASHER
PLATE ANCHORAGE; GRADE 75 STEEL.
CONTRACTOR TO PROVIDE & LOCATE
PLATE ASSEMBLY AS REQUIRED TO
DEVELOP TENSILE STRENGTH OF BAR
SPLICE, TYP.
CLASS 'B'
FULL-LENGTH VERT. BAR
CAGE (SEE SECTION A-A)
EL. -75'-0"±
FROM EXISTING GRADE
E.T.C.
SEE PLAN
2' - 3" (MIN.)
(4) #4 TIES AT 4" O.C.,
TYP.
PILE CAP SCHEDULE (18" DIA. / 75FT LENGTH)
SIZE OF PILE CAP
(L x W x D)
PILE CAP
MARK
REMA…