Addendum Two .pdf
PDF 2 MB Posted
- Solicitation number
- RFB-785-2400000371-3
- Issued by
- Henderson County, Kentucky
About this file
This document is an addendum to an Invitation to Bid (ITB) issued by the Commonwealth of Kentucky Department for Facilities and Support Services Division of Engineering and Contract Administration for the Interior Renovation of the Academic Technical Building at Henderson Community College in the Kentucky Community & Technical College System. The addendum provides updates to the specifications and drawings, including adding stamped ACCUREX drawings, replacing electrical drawings, and modifying the scope of work for the adjacent lab space. The addendum also revises the Alternate Bid No. 1 to include a fireplace and motorized roller shades in lieu of manually operated shades. The bid response date remains February 21, 2024.
The ITB includes an electrical legend, lighting fixture schedule, electrical demolition plans, power and systems plans, a one-line diagram, and detailed drawings for the kitchen exhaust hood, fire suppression system, and utility distribution system. The electrical work involves modifying existing circuits, connecting new lighting and equipment, and integrating the fire suppression system. The kitchen equipment includes an exhaust hood, exhaust fan, controls, and fire suppression system. Pricing, set asides, funding sources, and other salient commercial terms are not provided in the addendum.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Final_RFB_785_2400000371_1_SO_FORM.PDF | ||
| Addendum One .pdf | ||
| Final_RFB_785_2400000371_3_SO_FORM.PDF | ||
| Final_RFB_785_2400000371_2_SO_FORM.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-157-24
FOR: Interior Renovation Academic Technical Building Henderson Community College Kentucky Community & Technical College System Henderson, Kentucky
DATE: February 21, 2024
RFB-785-2400000371
ADDENDUM NO. Two (2)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-157-24 For: Interior Renovation Academic Technical Building Henderson Community College Kentucky Community & Technical College System Henderson, Kentucky
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
P a g e
T000-LASTNAME-
INT
Project: Addendum No.:
Date:
Owner: Project Number:
Contract for:
The original specifications and drawings dated October, 2023 for the project noted above are amended as noted in this Addendum Number 002. Receipt of this addendum and any subsequent addenda must be acknowledged on the final bid documents. This addendum consists of Ten (10) item(s) and Two (2) attachment(s).
2-1 Add stamped ACCUREX drawings attached. Work shown therein becomes part of the contract. Delete Addendum Item 1-1 noting drawings are for reference only.
2-2 Replace the Electrical Drawings in the Construction Documents noted “Not for Construction” with the Stamped Drawings attached.
2-3 Reference Sheet A1.1, Food Service Demolition, Floor & RCP Plans. At the adjacent Lab Space located south of the proposed kitchen, add a Dust Barrier Wall similar to that shown at Room 202 on Sheet A2.1, Cyber Café Demolition Plan & Floor Plan. Additionally add Dust Barrier Walls to the south exterior wall when concrete demolition and piping installation work is underway through the
Lab. Protect existing construction and furnishings.
2-4 Work in the adjacent Lab is restricted to no earlier than May 3 and no later than August 1, 2024.
2-5 Reference attached Sheets M5-1, M5-2, M5-3, M5-4, M5-5 and M5-6.
2-6 Disregard Addendum Item 1-2. Drawings M5-1, M5-2, M5-3, M5-4, M5-5 and M5-6 shall be included in the project. All material and labor associated with hood and fan shall be included.
2-7 Reference attached sheets E1-1, E1-2, E1-3, E1-4, E2-1, E2-2 and E3-1.
2-8 Reference attached sheet E2-1, for modifications for power feed to motorized roller shades.
2-9 Provide five (5) blinds, each +/- 11’-8” wide to cover the entire length of the curtain wall at
Room 202.
2-10 Change Alternate Bid No. 1 to read as follows:
P a g e
Attachments:
By:
CC:
Alternate No. 1
At Room 102, CYBER CAFÉ:
Manually Operated Roller Shades, as specified in Section 122413, Roller Window Shades, shall be installed at the existing curtainwall as part of the Base Bid. Base Bid also includes installation of all required electrical rough-in and wiring for a complete, future motorized installation.
This Alternate Bid is to furnish and install motorized Roller Shades in lieu of Manually Operated Roller Shades as described above.
Aquafire Fireplace (AWA-60-150) at the TV Feature Wall. Work includes creating the wall opening for the fireplace and all required electrical and plumbing rough-in for a complete installation. If this Alternate Bid is not accepted the fireplace will not be installed in the future and the opening and electrical and plumbing rough-in will not be required.
S a,b,c,...
WALL MOUNT JUNCTION BOX.
PHASE
CONDUCTOR
NEUTRAL
GROUND
LC1-1
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
SYMBOL DESCRIPTIONDESCRIPTIONSYMBOL
WALL OUTLET WITH 20A, 125V DUPLEX RECEPTACLE. MOUNT
18 INCHES ABOVE FINISHED FLOOR TO CENTER, UNLESS
NOTED OTHERWISE.
WALL OUTLET WITH 20A, 125V DUPLEX RECEPTACLE. MOUNT
46 INCHES ABOVE FINISHED FLOOR TO CENTER, OR 8 INCHES
ABOVE COUNTER OR COUNTER BACKSPLASH TO CENTER,
UNLESS NOTED OTHERWISE.
CEILING MOUNT JUNCTION BOX.
SYMBOL INDICATES FIXTURE TYPE WHEN SHOWN ON LIGHTING
PLANS AND SITE ELECTRICAL PLANS ADJACENT TO FIXTURE
SYMBOL. REFER TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE
REQUIREMENTS.
"GFI"
DATA OUTLET. MOUNT OUTLET AT SAME HEIGHT AS THE ASSOCIATED
POWER OUTLET, UNLESS NOTED OTHERWISE. PROVIDE 1 INCH CONDUIT
FROM OUTLET BOX TO NEAREST ACCESSIBLE CEILING CAVITY. BUSH
CONDUIT ENDS. PROVIDE TWO DATA CABLES TO OUTLET. OUTLET BOX
SHALL BE 4" SQUARE BY 2-3/4" DEEP WITH A SINGLE-GANG PLASTER RING,
UNLESS NOTED OTHERWISE. SEE "TYPICAL VOICE/DATA CONDUIT
INSTALLATION DETAIL" AND "TYPICAL VOICE/DATA AND POWER OUTLET
DETAIL" , THIS SHEET, FOR ADDITIONAL REQUIREMENTS.
DESCRIPTIONSYMBOL
OUTLET BOX AND 20A, SINGLE POLE SWITCH. MOUNT AT 46 INCHES
ABOVE FINISHED FLOOR TO CENTER, UNLESS NOTED OTHERWISE.
LOCATE WITHIN 8" OF STRIKE SIDE OF DOOR, UNLESS NOTED
OTHERWISE. LOWER CASE LETTER INDICATES CIRCUIT SWITCHED.
SYMBOL INDICATES GROUND FAULT INTERRUPTER TYPE
RECEPTACLE WHEN SHOWN PLANS ADJACENT TO
SYMBOL.
CEILING OUTLET AND EXIT LIGHT FIXTURE AS SCHEDULED.
ARROWS INDICATE DIRECTION ARROWS REQUIRED
PUSH BUTTON. (EMERGENCY POWER OFF)
LOWER CASE LETTERS INDICATE SWITCHING ARRANGEMENT
WHEN SHOWN NEXT TO OR WITHIN SYMBOL ON PLANS.
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
a
MULTI-FUNCTION FLOOR BOX.
ELECTRICAL LEGEND - POWERELECTRICAL LEGEND - LIGHTING ELECTRICAL LEGEND - TECHNOLOGY
TELECOMMUNICATIONS
J
J
EPO
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
CEILING MOUNT SMOKE DETECTOR.
DESCRIPTIONSYMBOL
FIRE ALARM SYSTEM
AUDIO-VISUAL ALARM DEVICE. FIRE ALARM SYSTEM. WALL
MOUNT AT SAME HEIGHT AS EXISTING DEVICES, OR 6 INCHES
BELOW CEILING TO TOP, WHICHEVER IS LOWER.
MANUAL PULL STATION. FIRE ALARM SYSTEM. MOUNT AT 46
INCHES A.F.F. TO CENTER, UNLESS NOTED OTHERWISE.
ELECTRICAL LEGEND - SYSTEMS
F
F S
F
WIRELESS NETWORK ACCESS SYSTEM OUTLET.
HOMERUN TO PANEL INDICATED. PREFIX INDICATES PANEL
NOMENCLATURE. NUMBERS INDICATE CIRCUIT NUMBERS.
CIRCUIT. NUMBER OF CROSSBARS INDICATE QUANTITY OF
CONDUCTORS REQUIRED. MINIMUM CONDUIT SIZE SHALL BE
3/4 INCH TRADE SIZE. MINIMUM SIZE CONDUCTORS SHALL BE
12 AWG.
F1
"EX" SYMBOL INDICATES EXISTING DEVICE WHEN SHOWN ON
PLANS ADJACENT TO SYMBOL.
NA
HALF-HATCHING PATTERN SHOWN WITHIN LIGHTING FIXTURE
SYMBOLS INDICATES FIXTURE CONNECTED TO EMERGENCY
BRANCH CIRCUIT.
S 3a
OUTLET BOX AND 20A, THREE-WAY SWITCH. MOUNT AT 46 INCHES
ABOVE FINISHED FLOOR TO CENTER, UNLESS NOTED OTHERWISE.
LOCATE WITHIN 8" OF STRIKE SIDE OF DOOR, UNLESS NOTED
OTHERWISE. LOWER CASE LETTER INDICATES CIRCUIT SWITCHED.
OUTLET BOX AND 20A, DIMMING SWITCH. MOUNT AT 46 INCHES
ABOVE FINISHED FLOOR TO CENTER, UNLESS NOTED OTHERWISE.
LOCATE WITHIN 8" OF STRIKE SIDE OF DOOR, UNLESS NOTED
OTHERWISE. LOWER CASE LETTER INDICATES CIRCUIT
SWITCHED.
a a
OCCUPANCY SENSOR. THE LETTER(S) DESIGNATION NEXT TO
THE SYMBOL (IF SHOWN) INDICATE SWITCHING ZONES TO BE
CONTROLLED VIA THE OCCUPANCY SENSOR. IF A LETTER
DESIGNATION IS NOT SHOWN, THE OCCUPANCY SENSOR SHALL
CONTROL ALL LIGHTING FIXTURES WITHIN THE ROOM. SEE
OCCUPANCY SENSOR CONTROL WIRING DIAGRAMS, AND
DETAILS, THIS SHEET, FOR ADDITIONAL REQUIREMENTS.
GTD
EMERGENCY POWER GENERATOR TRANSFER DEVICE. UL924
AND UL1008 LISTED FOR USE AS A SWITCH BYPASS OR
BRANCH CIRCUIT EMERGENCY LIGHTING TRANSFER SWITCH
AND RATED FOR CONNECTED LOAD AND VOLTAGE. PROVIDE
BODINE GTDU OR APPROVED EQUAL.
VISUAL ALARM DEVICE. FIRE ALARM SYSTEM. WALL
MOUNT AT SAME HEIGHT AS EXISTING DEVICES, OR 6 INCHES
BELOW CEILING TO TOP, WHICHEVER IS LOWER.
F
NOTE: COORDINATE EXACT OUTLET BOX INSTALLATION
LOCATIONS IN FIELD WITH ARCHITECT PRIOR TO ROUGH-IN.
INFORMATION OUTLET
BOXES. VIDEO OUTLET
BOXES, AND ASSOCIATED
POWER OUTLET BOXES
SHALL BE NEATLY GROUPED
TOGETHER AT THE SAME
MOUNTING HEIGHTS.
(TYPICAL, ALL LOCATIONS)
RECEPTACLE
VOICE / DATA
OUTLET BOX
FINISHED FLOOR
TYPICAL INFORMATION OUTLET AND
POWER OUTLET DETAIL
NO SCALE
EXTEND CONDUIT PAST
CEILING AND PROVIDE A
90° BEND IN CONDUIT.
BUSH CONDUIT ENDS.
EXTEND TO NEAREST
ACCESSIBLE CEILING
CAVITY
ACCESSIBLE
CEILING CAVITY
NON-
ACCESSIBLE
CEILING CAVITY
CONDUIT
ROUTED WITHIN
WALL
OUTLET BOX AS
SPECIFIED AND
NOTED
FINISHED FLOOR
TYPICAL INFORMATION OUTLET &
CONDUIT INSTALLATION
NO SCALE
GENERAL LIGHTING CONTROL NOTES:
R e d
W h t
Wht
Blk/Orn Blue
Blue
Relay (if req'd)
Normally Closed
Photocell (if req'd)
Common
Normally Open
Auto Dimming Ctrl (if req'd)
7-Brn
8-Vio
6-Gry
5-Blu
4-Vio w/ Wht stripe
3-Blk
2-Wht
1-Red
SWITCH "a" N
SWITCH "b"
Power Pack
Additional Occupancy
Sensor (qty. as shown on Lighting Plans)
3-WAY
SWITCH
3-WAY
SWITCH
4-WAY
SWITCH
UNSWITCHED HOT CONDUCTOR.
OPERATION & PROGRAMMING NOTE: OCCUPANCY SENSORS SHALL ALLOW
LIGHTING FIXTURES TO BE "TURNED ON" VIA THE LIGHTING CONTROL SWITCHES /
DIMMER SWITCHES WHEN OCCUPANCY HAS BEEN DETECTED. THE LIGHTING
FIXTURES SHALL REMAIN "ON" UNTIL THE AREA HAS BEEN FOUND TO BE
"UNOCCUPIED" FOR THE PROGRAMMED TIME PERIOD (OR WHENEVER THE
LIGHTING CONTROL SWITCH HAS BEEN TURNED "OFF". COORDINATE "ON"
DURATION TIME PERIODS FOR EACH TYPE OF ROOM WITH OWNER PRIOR TO
INSTALLATION OF THE OCCUPANCY SENSORS.
NOTE: CONTROL DIAGRAM IS TYPICAL FOR ALL SPACES WITH ONE OR MORE
SWITCHES AND ONE OR MORE OCCUPANCY SENSORS, UNLESS NOTED OTHERWISE.
SWITCHED HOT CONDUCTOR.
NOTE: SWITCH CONFIGURATIONS SHOWN FOR WIRING
REFERENCE ONLY. SWITCH CONFIGURATION FOR A PARTICULAR
SPACE SHALL BE A COMBINATION OF THE ABOVE TYPES OF
SWITCHES, QUANTITY AS INDICATED ON THE LIGHTING PLANS.
Occupancy
Sensor
LIGHTING CONTROL DIAGRAM - TYPICAL FOR ROOMS WITH SINGLE OR
MULTIPLE CONTROL SWITCHES & OCCUPANCY SENSORS
NO SCALE
7-Brn
8-Vio
6-Gry
5-Blu
4-Vio w/ Wht stripe
3-Blk
2-Wht
1-Red
B lk
Relay (if req'd)
Relay (if req'd)
Relay (if req'd)
Normally Closed
Photocell (if req'd)
Common
Normally Open
Auto Dimming Ctrl (if req'd)
Relay (if req'd)
Relay (if req'd)
A. OCCUPANCY SENSOR DESIGNS ARE BASED ON PRODUCTS BY SENSORSWITCH. CONTRACTOR SHALL BE RESPONSIBLE FOR
ANY DESIGN CHANGES REQUIRED TO USE PRODUCTS BY ANOTHER MANUFACTURER.
B. CEILING MOUNT SENSOR LOCATIONS SHALL BE TYPE AS REQUIRED FOR (AND RATED FOR USE) THE INSTALLED CEILING HEIGHT
AND THE INSTALLED ENVIRONMENT.
C IT IS NOT THE INTENT OF THIS DRAWING TO SHOW, NOR DOES THIS DRAWING SHOW EVERY CONFIGURATION OF LIGHTING CONTROL DIAGRAM REQUIRED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ALL LIGHTING CONTROL PER THE
LIGHTING CONTROL SYSTEM MANUFACTURER'S REQUIREMENTS.
D. CEILING MOUNT OCCUPANCY SENSORS SHALL BE DUAL TECHNOLOGY (PIR/MICROPHONICS) TYPE WHERE INSTALLED WITHIN
SPACES WHERE OCCUPANTS ARE STATIONARY FOR LONG PERIODS OF TIME.
E. DIMMER SWITCH ADJUSTMENTS. UNLESS NOTED OTHERWISE, ALL DIMMER SWITCHES SHALL BE ADJUSTED / SET TO AUTOMATICALLY TURN ASSOCIATED CONTROLLED LIGHTING FIXTURES "ON" TO THE PREVIOUS DIMMING LEVEL (I.E. AS WAS PRIOR
TO BEING "SHUT-OFF" BY OCCUPANCY SENSORS) WHEN THE ROOM BECOMES OCCUPIED.
F. DIMMER SWITCH ADJUSTMENTS. UNLESS NOTED OTHERWISE, ALL DIMMER SWITCHES SHALL BE ADJUSTED / SET TO AUTOMATICALLY TURN ASSOCIATED CONTROLLED LIGHTING FIXTURES "ON" TO THE PREVIOUS DIMMING LEVEL (I.E. AS WAS PRIOR TO BEING "SHUT-OFF" BY INTERGRAL "ON/OFF" SWITCH) WHEN THE INTEGRAL "ON/OFF" SWITCH IS PLACED IN THE "ON" CONDITION.
DIMMER SWITCH
(0-to-10V Type)
LTG FIXTURE(S) CONTROLLED VIA
DIMMER SWITCH (0-to-10V Type)
LOW VOLTAGE CTRL CKTS
(PER MFGR REQUIREMENTS)
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
CRAIG
34886
AJ SON
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/23
KCTCS - HCC FOOD SERVICE & CYBER CAFE
ELECTRICAL LEGEND
E1.1
ZWS
ZWS
ZWS
ADDENDUM #2 02/20/24
LIGHTING FIXTURE SCHEDULE
---F1D
F2D
MANUFACTURERSYMBOL DESCRIPTION
LOUVER FINISHTYPE
FIXTURE SERIES
LAMP
LENSWATTS REFLECTOR
MOUNTING
LIGHT CONTROL
REMARKS
FIXTURE
VOLTAGEQNTY PER
FIXTURE
F3
6' LENGTH LINEAR LED LIGHTING FIXTURE WITH FLUSH LENS
& WHITE FINISH. PROVIDE FIXTURE WITH CEILING TRIM FOR
INSTALLATION WITHIN T-GRID CEILING.
(FIXTURE DIMENSIONS: 6FT(L) x 4-1/8"(W) x 4"(D)).
[FIXTURE LUMEN OUTPUT ~ 6000 LUMENS]
SATIN
WHITE
120/277
(MULTI-
VOLT)
COOPER LTG
METALUX
QNTY AS
REQUIRED
35W
(NOMINAL
FIXTURE
INPUT
WATTS)
RECESSED,
T-GRID
CEILING
2'x4' LED LOW GLARE FLAT PANEL. CONTRACTOR SHALL
SELECT THE MEDIUM LUMEN OUTPUT POSITION.
(2.2" MAX FIXTURE DEPTH).
[FIXTURE LUMEN OUTPUT ~ 4500 LUMENS]
LEDS 3500K
(60,000 HRS WITH
70% LUMEN
MAINTENANCE)
L70/60
80+ CRI
CPX-2x4-AL08-80CRI-SWW7-SWL-
MVOLT SERIES
22FP3235C-80CRI-35K-NODIM-UNV
SERIES
LITHONIA
AXIS LIGHTING
BBRLED-1000-80-35-FL-6-W-UNV-
NODIM-1-RQD MOUNTING SERIES
LUMENWERX
VIA4R-D-HLO-FH-SW-80-1000-35-6FT-
UNV-D1-1C-XX-W-RQD MOUNTING
SERIES
RECESSED,
T-GRID
120/277
(MULTI-
VOLT)
61.7W
(NOMINAL
FIXTURE
INPUT
WATTS)
LEDS 3500K
(50,000 HRS
WITH 85% LUMEN
MAINTENANCE)
L85/50,000
80+ CRI MIN
QNTY AS
REQUIRED
4' LENGTH LINEAR LED LIGHTING FIXTURE WITH FLUSH LENS
& WHITE FINISH. PROVIDE FIXTURE WITH CEILING TRIM FOR
INSTALLATION WITHIN T-GRID CEILING.
(FIXTURE DIMENSIONS: 4FT(L) x 4-1/8"(W) x 4"(D)).
[FIXTURE LUMEN OUTPUT ~ 3200 LUMENS]
SATIN
WHITE
AXIS LIGHTING
BBRLED-800-80-35-FL-4-W-UNV-NODIM-1-
RQD MOUNTING SERIES
LUMENWERX
VIA4R-D-HLO-FH-SW-80-800-35-4FT-UNV-
D1-1C-XX-W-RQD MOUNTING SERIES
RECESSED,
T-GRID
120/277
(MULTI-
VOLT)
31.5W
(NOMINAL
FIXTURE
INPUT
WATTS)
LEDS 3500K
(50,000 HRS
WITH 85% LUMEN
MAINTENANCE)
L85/50,000
80+ CRI MIN
QNTY AS
REQUIRED
SATIN
WHITE
F5
120/277
(MULTI-
VOLT)
HALO
QNTY AS
REQUIRED
31.6W
(NOMINAL
FIXTURE
INPUT
WATTS)
RECESSED
CLEAR,
SEMI-
SPECULAR
8" APERATURE LED DOWNLIGHT FIXTURE WITH A MAXIMUM
DEPTH OF 8"
[FIXTURE LUMEN OUTPUT ~ 2000 LUMENS]
LEDS 3500K
(60,000 HRS WITH
70% LUMEN
MAINTENANCE)
L70/60
80+ CRI
HC820D010-HM60525835-61MDH
SERIES
LITHONIA
END OF LIGHTING FIXTURE SCHEDULE
F4
120/277
(MULTI-
VOLT)
COOPER LTG
METALUX
QNTY AS
REQUIRED
27.7W
(NOMINAL
FIXTURE
INPUT
WATTS)
RECESSED,
T-GRID
CEILING
2'x2' LED LOW GLARE FLAT PANEL. CONTRACTOR SHALL
SELECT THE MEDIUM LUMEN OUTPUT POSITION.
(2.2" MAX FIXTURE DEPTH).
[FIXTURE LUMEN OUTPUT ~ 3200 LUMENS]
LEDS 3500K
(60,000 HRS WITH
70% LUMEN
MAINTENANCE)
L70/60
80+ CRI
CPX-2x2-AL07-80CRI-SWW7-SWL-
MVOLT SERIES
22FP3235C-80CRI-35K-NODIM-UNV
SERIES
LITHONIA
SATIN
WHITE
EX1
120/277
(MULTI-
VOLT)
QNTY AS
REQUIRED
LESS
THAN 5W
SURFACE,
CEILING
EXIT LIGHTING FIXTURE, WHITE THERMOPLASTIC HOUSING,
SINGLE-FACE WITH RED LETTERS.
LEDS (RED)
LQM QUANTUM SERIESLITHONIA
LBR8-20LM-35K-AR-LSS-MWD-MVOLT
SERIES
F5D
120/277
(MULTI-
VOLT)
HALO
QNTY AS
REQUIRED
31.6W
(NOMINAL
FIXTURE
INPUT
WATTS)
RECESSED
CLEAR,
SEMI-
SPECULAR
SAME FIXTURE AS TYPE "F5" EXCEPT PROVIDE FIXTURE
WITH CAPABILITIES TO DIM TO 10% USING 0-TO-10V
CONTROLS.
LEDS 3500K
(60,000 HRS WITH
70% LUMEN
MAINTENANCE)
L70/60
80+ CRI
HC820D010-HM60525835-61MDH
SERIES
LITHONIA
LBR8-20LM-35K-AR-LSS-MWD-MVOLT
SERIES
1. PROVIDE FIXTURE WITH 0-TO-10V DIMMING CONTROLLER(S) [QNTY AS INDICATED ON LIGHTING
PLAN] FULLY COMPATIBLE WITH THE FIXTURE AND RATED FOR OPERATION WITH THE FIXTURE
AND CONNECTED LOAD. FINISH COLOR OF THE DIMMING CONTROLLER(S) AND DEVICE PLATES
SHALL MATCH THE COLOR OF ALL OTHER WIRING DEVICES / DEVICE PLATES CONNECTED TO
THE ASSOCIATED POWER SOURCE
1. PROVIDE FIXTURE WITH 0-TO-10V DIMMING CONTROLLER(S) [QNTY AS INDICATED ON LIGHTING
PLAN] FULLY COMPATIBLE WITH THE FIXTURE AND RATED FOR OPERATION WITH THE FIXTURE
AND CONNECTED LOAD. FINISH COLOR OF THE DIMMING CONTROLLER(S) AND DEVICE PLATES
SHALL MATCH THE COLOR OF ALL OTHER WIRING DEVICES / DEVICE PLATES CONNECTED TO
THE ASSOCIATED POWER SOURCE
1. PROVIDE FIXTURE WITH 0-TO-10V DIMMING CONTROLLER(S) [QNTY AS INDICATED ON LIGHTING
PLAN] FULLY COMPATIBLE WITH THE FIXTURE AND RATED FOR OPERATION WITH THE FIXTURE
AND CONNECTED LOAD. FINISH COLOR OF THE DIMMING CONTROLLER(S) AND DEVICE PLATES
SHALL MATCH THE COLOR OF ALL OTHER WIRING DEVICES / DEVICE PLATES CONNECTED TO
THE ASSOCIATED POWER SOURCE
1. CONTRACTOR MAY UTILIZE FIXED LUMEN OUTPUT.
1. CONTRACTOR MAY UTILIZE FIXED LUMEN OUTPUT.
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
CRAIG
34886
AJ SON
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/23
KCTCS - HCC FOOD SERVICE & CYBER CAFE
LIGHTING FIXTURE SCHEDULE
E1.2
ZWS
ZWS
ZWS
F
F
F S
F S
F S
F S
F S
NA
GENERAL DEMOLITION NOTES:
GD1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE
BUILDING AND SITE TO BECOME FAMILIAR WITH THE EXISTING
CONDITIONS. THESE REMOVAL DRAWINGS SHALL SERVE TO AID THE
CONTRACTOR IN HIS EVALUATION OF THE EXTENT OF REMOVALS, BUT
SHALL NOT BE HELD TO BE ALL INCLUSIVE.
GD2. FOR FURTHER REQUIREMENTS WITH REGARD TO EXTENT OF
REMOVALS, SEE THE NEW CONSTRUCTION PLANS WHICH ILLUSTRATE
THE ADJACENT NEW CONSTRUCTION.
GD3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOVALS
REQUIRED FOR THE INSTALLATION OF NEW WORK, WHETHER OR NOT
IT IS SPECIFICALLY INDICATED OR NOTED IN THESE DOCUMENTS.
GD4. ALL EQUIPMENT REMOVED FOR RELOCATION SHALL BE
REMOVED IN SUCH A MANNER THAT REUSE IS POSSIBLE.
GD5. ALL CONDUIT RUNS TO REMOVED EQUIPMENT SHALL HAVE ALL
CONDUCTORS REMOVED, UNLESS CONDUCTORS ARE REQUIRED TO
SERVE EXISTING EQUIPMENT TO REMAIN.
GD6. REMOVAL OF EMPTY CONDUIT SHALL BE REQUIRED ONLY IF
SUCH CONDUIT INTERFERES WITH THE NEW CONSTRUCTION AND/OR IF
INDICATED TO BE DISCONNECT AND REMOVED COMPLETE BACK TO
SOURCE OF FEED.
GD7. IF PORTIONS OF CIRCUITS SERVING EQUIPMENT TO REMAIN
MUST BE RELOCATED OR REMOVED DUE TO OTHER DEMOLITION OR
DUE TO INTERFERENCE WITH NEW EQUIPMENT INSTALLATION, THE
CIRCUITS SHALL BE MODIFIED IN A MANNER WHICH SHALL ENSURE
PROPER OPERATION OF THE EQUIPMENT AFTER THE CONSTRUCTION
IS COMPLETE. CONTRACTOR SHALL USE THE SAME GAUGE AND TYPE
OF CONDUCTOR, AND THE SAME CONDUIT SIZE AS EXISTING TO MAKE
ALL REQUIRED CIRCUIT MODIFICATIONS.
GD8. IF WALLS, CEILINGS, FLOORS, OR EQUIPMENT ARE REMOVED, OR
OTHER DEMOLITION OCCURS, WHICH EXPOSES CIRCUITS SERVING
EQUIPMENT TO REMAIN, THE CIRCUITS SHALL BE RELOCATED OR
MODIFIED IN SUCH A MANNER WHICH SHALL ENSURE THE CONTINUED
OPERATION OF THE CIRCUIT. EXISTING CONDUITS EXPOSED DURING
DEMOLITION WHICH REMAIN TO SERVE EQUIPMENT SHALL BE
RESUPPORTED IN ACCORDANCE WITH THE REQUIREMENTS OF THE
NEC.
GD9. EQUIPMENT REMOVED FOR RELOCATION BUT NOT RELOCATED
SHALL BE STORED AT A LOCATION DIRECTED BY THE OWNER.
GD10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER
DISPOSAL OF ALL EQUIPMENT REMOVED.
GD11. OWNER RESERVES THE FIRST RIGHT OF REFUSAL OF REMOVED
EQUIPMENT.
GD12. THE CONTRACTOR SHALL COORDINATE DISRUPTION OF
SERVICES WITH THE OWNER. DISRUPTIONS OF SERVICES SHALL BE
KEPT TO A MINIMUM. DISRUPTIONS SHALL ONLY OCCUR AFTER
RECEIVING OWNER PRIOR APPROVAL.
GD13. THE CONTRACTOR SHALL REFER TO THE MECHANICAL,
PLUMBING, AND ARCHITECTURAL PLANS FOR ADDITIONAL
REQUIREMENTS ON EQUIPMENT AND AREAS REQUIRING
DISCONNECTIONS AND REMOVALS.
GD14. ALL WALL/CEILING MOUNT DEVICES AND FACEPLATES SHALL BE
REMOVED AS REQUIRED FOR WALL FINISH INSTALLATION. PROVIDE ALL
LABOR AND MATERIAL TO INSTALL DEVICES WITHIN EXISTING JUNCTION
BOXES (PROVIDING BOX AND EXTENDERS AS REQUIRED).
GD15. IT IS NOT THE INTENT OF THIS DRAWING TO SHOW ALL EXISTING
ELECTRICAL DEVICES, EQUIPMENT, AND ITEMS TO BE DISCONNECTED
AND REMOVED. THIS DRAWING DOES NOT SHOW ALL ELECTRICAL
DEVICES, EQUIPMENT, AND ITEMS TO BE DISCONNECTED AND
REMOVED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING
THE PROJECT AREAS TO BECOME FAMILIAR WITH THE EXISTING
CONDITIONS AND TO DETERMINE THE AMOUNT OF REMOVALS.
LTG
CONTACTOR
PANEL "L1"
PANEL "M1"
PANEL "E1"
PANEL "C1"
XFMR#3
PANEL "R1"
XFMR#2
GE EST F.A.
CONTROL PANEL
F.A. BOOSTER
PANEL
NOTE D1
NOTE D2
NOTE D2
NOTE D3
NOTE D3
NOTE D3
NOTE D5
NOTE D5
NOTE D5
NOTE D5
NOTE D4
NOTE D6
PANEL "EE"
NOTE D5 NOTE D5 NOTE D5 NOTE D5
NOTE D5
NOTE D5
NOTE D5NOTE D5NOTE D5
NOTE D5
NOTE D5 NOTE D5
NOTE D5
NOTE D2
NOTE D1
R1-6R1-5R1-4R1-3
R1-2
R1-2
R1-2
R1-2R1-2
R1-2
C1-1
C1-1
C1-1
C1-2 C1-2 C1-2 C1-2
R1-31R1-30
NOTE D7,
TYPICAL ALL LOCATIONS.
NOTE D5
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
CRAIG
34886
AJ SON
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/23
KCTCS - HCC FOOD SERVICE & CYBER CAFE
ELECTRICAL DEMO PLAN - SULLIVAN TECHNOLOGY CENTER
E1.3
ZWS
ZWS
ZWS
1/4" = 1'-0"
ELECTRICAL DEMOLITION PLAN - SULLIVAN TECHNOLGY BUILDING - FIRST FLOOR
DEMOLITION NOTES:
D1. DISCONNECT AND REMOVE RECEPTACLE. EXISTING CIRCUIT
SHALL REMAIN AND SHALL BE REWORKED AS REQUIRED FOR REUSE.
D2. DISCONNECT AND REMOVE DATA DEVICE AND ASSOCIATED
CIRCUIT COMPLETE BACK TO SOURCE OF FEED.
D3 DISCONNECT AND REMOVE RECEPTACLE AND ASSOCIATED
CIRCUIT COMPLETE BACK TO SOURCE OF FEED.
D4. DISCONNECT AND REMOVE FIRE ALARM DEVICE AND
ASSOCIATED CIRCUIT COMPLETE BACK TO SOURCE OF FEED.
D5. DISCONNECT AND REMOVE LIGHTING FIXTURE. EXISTING CIRCUIT
SHALL REMAIN AND SHALL BE REWORKED AS REQUIRED FOR REUSE.
D6. DISCONNECT, REMOVE, REWORK AND REINSTALL FIRE ALARM
DEVICE IN SAME GENERAL LOCATION FOR WALL INSTALLATION.
D7. NOMENCLATURE INDICATED PANEL AND CIRCUIT WHICH SERVES
DEVICE PER RECORD DRAWINGS DATED 07-2008.
1'0' 2' 4'
1/4''=1'-0'' North
T
F
F S
S S
S
F
F S
F S
S
F S
NOTE 5
NOTES 2, 3, 4 & 6.
NOTE 7
NOTE 1
NOTE 1
NOTE 8
NOTE 8
NOTE 9
NOTE 10
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
CRAIG
34886
AJ SON
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/23
KCTCS - HCC FOOD SERVICE & CYBER CAFE
ELECTRICAL DEMO PLAN - ACADEMIC TECHNICAL BUILDING
E1.4
ZWS
ZWS
ZWS
1/4" = 1'-0"
ELECTRICAL DEMOLITION PLAN SERVING AREA
DEMOLITION NOTES:
1. DISCONNECT AND REMOVE FIRE ALARM DEVICE COMPLETE
BACK TO SOURCE OF FEED.
2. DISCONNECT AND REMOVE ALL RECEPTACLES WITHIN DASHED
LINE TYPE, UNLESS NOTED OTHERWISE. DISCONNECT AND REMOVE
ALL ASSOCIATED CIRCUITS COMPLETE BACK TO SOURCE OF FEED.
3. DISCONNECT AND REMOVE ALL DATA DEVICES WITHIN DASHED
LINE TYPE, UNLESS NOTED OTHERWISE. DISCONNECT AND REMOVE
ALL ASSOCIATED DATA CABLES COMPLETE BACK TO SOURCE OF
FEED.
4. DISCONNECT AND REMOVE DEVICES WITHIN FLOOR BOX,
WITHIN DASHED LINE TYPE. DISCONNECT AND REMOVE ALL
ASSOCIATED CIRCUITS COMPLETE BACK TO SOURCE OF FEED.
FLOORBOX SHALL BE ABANDONED IN PLACE. CONTRACTOR SHALL
PROVIDE BLANK COVER.
5. DISCONNECT AND REMOVE PANEL "EL" COMPLETE BACK TO
SOURCE OF FEED. DISCONNECT AND REMOVE FEEDER COMPLETE
BACK TO SOURCE OF FEED.
6. DISCONNECT AND REMOVE ALL LIGHTING FIXTURES WITHIN
DASHED LINE TYPE, UNLESS NOTED OTHERWISE. EXISTING CIRCUIT
SHALL REMAIN AND SHALL BE REWORKED AS REQUIRED FOR
REUSE.
7. DISCONNECT AND REMOVE TELEPHONE EQUIPMENT AND
TELEPHONE BACKBOARD COMPLETE BACK TO SOURCE OF FEED.
8. DISCONNECT AND REMOVE FIRE ALARM DEVICE FOR
RELOCATION. EXISTING CIRCUIT SHALL BE REMAIN AND SHALL BE
REWORKED AS REQUIRED TO SERVE DEVICE AT NEW LOCATION.
9. DISCONNECT AND REMOVE LIGHTING FIXTURE FOR
RELOCATION. EXISTING CIRCUIT SHALL REMAIN AND SHALL BE
REWORKED AS REQUIRED FOR REUSE.
10. DISCONNECT AND REMOVE SWITCHES FOR RELOCATION.
SWITCH-LEG CONDUCTORS SHALL BE REWORKED AS REQUIRED
FOR INSTALLATION. CONTRACTOR SHALL FIELD VERIFY EXACT
SWITCH TYPE INSTALLED (I.E. SINGLE POLE, 3WAY, 4WAY, ETC.) FOR
REINSTALLATION. CONTRACTOR SHALL PROVIDE NEW SWITCHES.
1'0' 2' 4'
1/4''=1'-0''
F S
F S
F S
F S
NA
F
F
JJ
JJ
J
S
S
EXEX EXEX EXEX EXEX
EX
EX
NOTE 5
EX
EX
NOTE 2
EX
EX
EX
EX
EX
EX
EX
GFIGFI
GFI
NOTE 4
NOTES 2 & 7.
NOTE 4
NOTE 4
NOTES 2 & 8.
EXISTING LTG
CONTACTOR
EXISTING PANEL "L1"
EXISTING PANEL "M1"
EXISTING PANEL "E1"
EXISTING PANEL "C1"
EXISTING XFMR#3
EXISTING PANEL "R1"
EXISTING XFMR#2
EXISTING GE EST
F.A. CONTROL
PANEL
EXISTING F.A.
BOOSTER PANEL
EXISTING
PANEL "EE"
EX
EX
NOTE 2
NOTE 5
NOTE 3
NOTE 8
NOTE 10
NOTE 8 NOTES 2 & 8.
NOTES 2 & 8.
EX EX EX EX EX EX EX
F1D F1D F1D F1D F1D F1D F1D F1D F1D
F2DF2DF2DF2D
NOTE 6
NOTE 6EX1
EX1
3a
3a
GTD
F5D
F5DF5DF5DF5DF5DF5D
c
GTDGTD
cccccc c b a aaaa bbbbbbbbb
EX1
a a
GTD
NOTE 9 NOTE 9 NOTE 9
NOTE 9
NOTE 1
NOTE 1
NOTE 1
NOTE 11NOTE 11NOTE 11
NOTE 11
F4
F4
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
CRAIG
34886
AJ SON
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/23
KCTCS - HCC FOOD SERVICE & CYBER CAFE
ELECTRICAL PLANS - SULLIVAN TECHNOLOGY CENTER
E2.1
ZWS
ZWS
ZWS
1/4" = 1'-0"
POWER AND SYSTEMS PLAN - STC - FIRST FLOOR
1/4" = 1'-0"
LIGHTING PLAN - STC - FIRST FLOOR
NOTES: CON'T
5. POINT OF CONNECTION TO EXISTING.
6. UTILIZE EXISTING NORMAL CIRCUIT WHICH SERVED LIGHTING IN
AREA TO SERVE NEW FIXTURES. PROVIDE ALL REQUIRED
CONDUCTORS FOR CONTROL OF FIXTURES AS INDICATED.
7. AS PART OF ALTERNATE BLINDS AND FIREPLACE, PROVIDE
RECEPTACLE AND DEDICATED 120V, 20A BRANCH CIRCUIT FOR
WATER VAPOR FIREPLACE. COORDINATE INSTALLATION LOCATION
WITH ARCHITECT AND FIREPLACE MANUFACTURER PRIOR TO
ROUGH-IN.
8. AS PART OF ALTERNATE BLINDS AND FIREPLACE, PROVIDE
RECEPTACLE AND DEDICATED 120V, 20A BRANCH CIRCUIT FOR
ELECTRIC BLIND SYSTEM. PROVIDE FINAL CONNECTION PER
EQUIPMENT MANUFACTURER'S REQUIREMENTS. COORDINATE
INSTALLATION LOCATION WITH EQUIPMENT VENDOR AND ARCHITECT
PRIOR TO START OF ROUGH-IN.
9. CONNECT GENERATOR TRANSFER DEVICE TO EXISTING NORMAL
AND EXISTING EMERGENCY CIRCUIT WHICH SERVES EMERGENCY
AND EGRESS LIGHTING IN AREA. PTOVIDE ALL CONNECTIONS AS
REQUIRED FOR CONTROL AS INDICATED.
10. REINSTALL FIRE ALARM DEVICE REMOVED FOR RELOCATION.
PROVIDE ALL MODIFICATIONS AS REQUIRED FOR RELOCATION.
11. FIXTURE SHALL BE POWERED AND CONTROLLED VIA GTD DEVICE.
1'0' 2' 4'
1/4''=1'-0'' North
1'0' 2' 4'
1/4''=1'-0'' North
NOTES:
1. CONNECT FIXTURE TO EXISTING EMERGENCY CIRCUIT WHICH
SERVES EGRESS AND EMERGENCY FIXTURES WITHIN AREA.
2. UTILIZE CIRCUIT MADE AVAILABLE DURING DEMOLITION TO SERVE
LOAD. CONTRACTOR SHALL DOCUMENT PANEL AND CIRCUIT ON AS-
BUILT DRAWINGS.
3. PROVIDE FIRE ALARM DEVICE COMPATIBLE WITH GE EST FIRE
ALARM CONTROL PANEL AND CONNECT TO EXISTING BUILDING FIRE
ALARM SYSTEM.
4. RECEPTACLE AND DATA DEVICE FOR WALL MOUNT TV.
COORDINATE MOUNTING HEIGHT IN FIELD WITH ARCHITECT PRIOR
TO ROUGH-IN.
J
JJ
J
F
MM
F J
J J
J J
J J
S
S S
S
NOTE 4
NOTE 5
NOTE 6
NOTE 6
NOTE 2
NOTE 1
EX
NOTE 3
NOTE 6
NOTE 6
NOTE 6
NOTE 10
PANEL "K1"
NOTE 12
FOOD SERVICES
CORRIDOR
CLASSROOM
F3F3F3
F3 F3 F3
NL
a a a aa a
NOTE 7
NOTE 8
NOTE 9
NOTE 11
EXEX EX
EXEX EX
EXEX EX
EXEX EX
EXEX EX
F5
F5
NOTE 13
FOOD SERVICES
CORRIDOR
CLASSROOM
PANEL "K1"
EXISTING MAIN
SWITCHGEAR
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
CRAIG
34886
AJ SON
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/23
KCTCS - HCC FOOD SERVICE & CYBER CAFE
ELECTRICAL PLANS - ACADEMIC TECHNICAL BUILDING
E2.2
ZWS
ZWS
ZWS
1/4" = 1'-0"
POWER & SYSTEMS PLAN SERVING AREA
1/4" = 1'-0"
LIGHTING PLAN SERVING AREA
NOTES:
1. PROVIDE MONITORING MODULE FOR MONITORING OF KITCHEN
HOOD FIRE SUPPRESSION SYSTEM. COORDINATE INSTALLATION
WITH KITCHEN EQUIPMENT VENDOR. REFER TO KITCHEN DRAWINGS
FOR ADDITIONAL REQUIREMENTS.
2. PROVIDE 208Y/120V, 200A, 3Ø FEEDER CIRCUIT FROM EXISTING
MAIN SWITCHGEAR TO THE PANELBOARD, WITH SHUNT-TRIP MAIN
BREAKER, PROVIDED WITHIN THE UTILITY DISTRIBUTION SYSTEM
"UDS-1". COORDINATE ALL INSTALLATION REQUIREMENTS WITH
"UDS-1" AND KITCHEN EQUIPMENT PROVIDER PRIOR TO START OF
ROUGH-IN. REFER TO ONE-LINE DIAGRAM, SHEET E3.1, FOR
ADDITIONAL REQUIREMENTS.
3. PROVIDE 120V, 20A BRANCH CIRCUIT TO SERVE UTILITY
DISTRIBUTION SYSTEM POWER FOR CONTROLS/LIGHTS PER
EQUIPMENT MANUFACTURER'S REQUIREMENTS. PROVIDE ALL
REQUIRED CIRCUITS FOR A COMPLETE AND OPERATIONAL SYSTEM.
UTILIZE 2#12, 1#12G AND 3/4"C FROM PANEL "K1" CIRCUIT 2.
4. PROVIDE 120V, 20A, GFI PROTECTED BRANCH CIRCUIT AND
RECEPTACLE FROM PANEL "K1" CIRCUIT 1 TO SERVE
REFRIGERATOR.
5. PROVIDE 120V, 20A, GFI PROTECTED BRANCH CIRCUIT AND
RECEPTACLE FROM PANEL "K1" CIRCUIT 3 TO SERVE FREEZER.
6. PROVIDE JUNCTION BOX MOUNTED AT 18" A.F.F AND 3/4"C
ROUTED TO ACCESSIBLE CEILING FOR FUTURE INSTALLATION OF
KITCHEN EQUIPMENT. PROVIDE BLANK STAINLESS STEEL
COVERPLATE.
7. UTILIZE EXISTING LIGHTING CIRCUITS WHICH SERVED LIGHTING
IN AREA TO SERVE NEW FIXTURES. FIXTURES SHALL BE
CONTROLLED AS INDICATED.
8. UTILIZE CIRCUIT WHICH SERVES CORRIDOR TO SERVE FIXTURE.
FIXTURE SHALL BE CONTROLLED SAME AS CORRIDOR LIGHTING.
9. PROVIDE SWITCHES BASED UPON FIELD VERIFICATION. REWORK
AND EXTEND ALL ASSOCIATED CIRCUITS AS REQUIRED. LIGHTING
CONTROL SWITCHES AND CONNECTED LOAD SHALL OPERATE AS
WAS PRIOR TO START OF DEMOLITION.
10. UTILIZE FIRE ALARM DEVICE REMOVED FOR RELOCATION.
REWORK AND CONNECT TO EXISTING FIRE ALARM CIRCUIT WHICH
SERVED DEVICE PRIOR TO DEMOLITION.
11. UTILIZE LIGHTING FIXTURE REMOVED FOR RELOCATION AND
CONNECT TO EXISTING CIRCUIT WHICH SERVED FIXTURE PRIOR TO
DEMOLITION.
12. PROVIDE 208V, 25A, 1Ø BRANCH CIRCUIT FROM PANEL "K1"
CIRCUIT 13 FOR KITCHEN HOOD EXHAUST FAN. UTILIZE 2#10, 1#10G
AND 3/4"C TO SERVE LOAD. PROVIDE ALL REQUIRED CONTROL
CIRCUITS FROM EXHAUST FAN TO KITCHEN HOOD CONTROL PANEL.
PROVIDE FINAL EQUIPMENT CONNECTIONS PER MANUFACTURER
REQUIREMENTS. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR
ADDITIONAL DETAILS.
13. UTILIZE NEAREST EMERGENCY BRANCH CIRCUIT WHICH SERVED
EGRESS LIGHTING TO SERVE FIXTURE. CONTRACTOR SHALL
DOCUMENT PANEL AND CIRCUIT NUMBER ON AS-BUILT DRAWINGS.
1/16" = 1'-0"
AREA PLAN
1'0' 2' 4'
1/4''=1'-0'' North
1'0' 2' 4'
1/4''=1'-0''
M
1 2 3 5 6 7 8 11 1312 14 159 104 16
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
30 20A
28 20A
SPARE
24 30A
20 30A19
SPARE
SPARE
30A
SPARE
12 20A
8 20A7
SPARE
SPARE
4 40A
2 20A1
SPARE
EXHAUST HOOD SYSTEM
225A, 208Y/120V, 3PH, 4W
RECESSED MOUNT
42 SPACE
22,000 A.I.C.
PROVIDE WITH HINGED COVER ENCLOSURE
PANEL "K1"
20A SPARE
SPARE
20A
GFI
20A
GFI
20ASPARE
25AKITCHEN HOOD EXHAUST FAN
FREEZER
REFRIGERATOR
20A
GFISPARE
20A
GFISPARE
SPACE
SPACE
SPACE
3231SPACE
SPACE
SPACE
3837SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
20ASPARE
20ASPARE
20ASPARE
NO SCALE
ONE-LINE DIAGRAM
EXISTING MAIN SWITCHGEAR
208Y/120V, 3Ø, 4W, 2000A, 65,000 A.I.C.
GE AV-LINE SWITCHBOARD
2000A/3
EXISTING
PANEL
"A1"
EXISTING
PANEL
"A2"
TO D.P.B. #2 UNKNOWN
LOAD
EXISTING
PANEL
"ML"
EXISTING
PANEL
"EL"
TO ATS-7
(EXISTING
PANEL "ATE")
TO VACUUM
PUMP
200A/3 200A/3 600A/3 600A/3 30A/3 100A/3100A/3 60A/3 60A/3
PANEL
"K1"
4#2, 1#8, 1-1/2"C
NOTE 1
NOTE 2
EXISTING
PANEL
"MT"
200A/3
TO CHILLER
FEED #1
600A/3
TO CHILLER
FEED #2
SPACE SPACE
TO D.P.B. #1
400A/3
EXISTING
PANEL
"BS"
200A/3
TO C.W.
PUMP 2
60A/3
CONTINUED BELOW
CONTINUED
FROM ABOVE
60A/3
TO C.W.
PUMP 1
TO BOILER
60A/3
TO AIR
COMPRESSOR
40A/3 40A/3
TO H.W.
PUMP 1
40A/3
TO H.W.
PUMP 2
100A/3
TO AHU#1
100A/3
TO COND.
UNIT #1
60A/3
UNKNOWN
LOAD
400A/3
TO 400A
BUSS DUCT
(OFF)
SPACE
125A/3
TO AHU#2
125A/3
TO
ELEVATOR
(OFF)
200A/3 225A/3
TO ATS-8
(EXISTING
PANEL "EP4")
SPACE SPACE
NOTE 3
UTILITY
DISTRIBUTION
SYSTEM "UDS-1"
(LOCATED WITHIN
KITCHEN HOOD)
4#3/0, 1#6, 2"C
NOTE 2
NOTES 4 & 5.
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
CRAIG
34886
AJ SON
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/23
KCTCS - HCC FOOD SERVICE & CYBER CAFE
ONE-LINE DIAGRAM AND BUSSING DIAGRAM - A/T BUILDING
E3.1
ZWS
ZWS
ZWS
NOTES:
1. DISCONNECT AND REMOVE ALL ELECTRICAL EQUIPMENT WITHIN
HATCHED REGION.
2. POINT OF CONNECTION TO EXISTING EQUIPMENT.
3. PROVIDE NEW DISTRIBUTION LABELS ON EXISTING BREAKERS.
PROVIDE TYPED LAMINATED INDEXCARD WHICH CORRECTLY
IDENTFIES CONNECTED LOADS.
4. UTILITY DISTRIBUTION SYSTEM "UDS-1" PROVIDED WITH
FACTORY INSTALLED MAIN BREAKER WITH SHUNT-TRIP.
5. ALL KITCHEN EQUIPMENT SHALL BE PROVIDED WITH GFCI TYPE
CIRCUIT BREAKERS.
CHROME APPLIANCE DROPS
ROUND LED LIGHT DETAIL
115VAC HOT
115VAC NEUTRAL
GROUND
BLACK
WHITE
GREEN
BLACK
WHITE
GREEN
FIRST LED
HOOD LIGHT
SECOND LED
HOOD LIGHT
LAST LED
HOOD LIGHT
LIGHT QTY
BASED ON
CONFIGURATION
NOTES:
VOLTAGE: 115VAC, 50-60HZ
WATTAGE: 20W EACH
AMPERAGE: 0.167A EACH
LUMENS: 1800
CONDUIT PORTS: 2 EACH
(1/2" - 14 NPT)
COLOR: 3900 - 4100K
DIMMABLE (0-10VDC)
BLACK (115VAC HOT)
WHITE (115VAC NEUTRAL)
GREEN (GROUND)
PURPLE (DIM 0-10VDC +)
GRAY (DIM 0-10VDC -)
8.0
DRAWING NOT TO SCALE
SECURE PANELS
TO WALL STUDS
(HOLES AND FASTENERS
BY OTHERS)
SLIDE
PANEL
BEHIND
HOOD
FLAT
BACKSPLASH
PANEL
FASTEN TO WALL
HARDWARE BY OTHERS
5/16'' BOLTS
PROVIDED BY
MANUFACTURER
CLAMPS
PROVIDED BY MANUFACTURER
HOOD TOP
1" INSULATION
FULL WALL
END FILLER PANEL
PARTIAL WALL
END FILLER PANEL
1" INSULATION
HOOD LENGTH
3.6
TYPICAL
HANGER
BRACKET
3.6
4.0
2.6
THREADED
ROD (1/2")
WASHER
HANGER
BRACKET
1/2" NUT
TEMPERATURE SENSORS
FIELD WIRING TO CONTROLS REQUIRED
USER
INTERFACE:
TOUCH
SCREEN
REMOVABLE GREASE CUP W/
CONCEALED GREASE TROUGH
UL LISTED HIGH EFFICIENCY
'GREASE-X-TRACTOR' FILTERS
UL LISTED LED LIGHT FIXTURE
X K
C
IT
E
M
E
X H
A U
S T
H O
O D
H E
N D
E R
S O
N C
O M
M U
N
IT
Y C
O L L E
G E
A C
C U
R E
X S
O U
T H
O H
K Y
I N
A A R O N
G E A R H A R T
A A
R O
N .G
E A
R H
A R
T
A C
C U
R E
X .C
O M
(5
)5
-5
P R
O J E
C T
M A
R K
/2
/2
2 FP
2W
2 FP
3 FP
3N
2 FP
1 FP
1N
1 FP
1N
48 24
MODEL
LENGTH WIDTH HEIGHT
HOOD DIMENSIONS (IN.)
MARK
WIDTH LENGTH DIA. CFM S.P.
COLLAR(S)
EXHAUST
HOOD INFORMATION
HOOD
NO.
COOKING
LOAD /
DUTY
RATING
HOOD
CONSTR. MUA
CFM
AC
CFM
TOTAL
WEIGHT
LBS.
SECTION
LOCATIONTOTAL
CFM
SUPPLY
HOOD OPTIONS
UL 710 LISTED W/ OUT EXHAUST FIRE DAMPER - UL #R25625
BACK INTEGRAL AIR SPACE - 3 IN WIDE
LEFT NON-INTEGRAL AIR SPACE - 1 IN THICK - ZERO CLEARANCE
4 IN HIGH CEILING ENCLOSURES - FRONT RIGHT - FIELD INSTALLED
FACTORY MOUNTED EXHAUST COLLAR(S)
BACKSPLASH 108.00 IN HIGH 199.00 IN LONG
PERFORMANCE ENHANCING LIP (PEL) TECHNOLOGY
STANDING SEAM CONSTRUCTION FOR SUPERIOR STRENGTH
A N
S U
L R
R E
L E
A S
E O
E M
T A
N K
3" REAR INTEGRAL AIR SPACE
FLAT BACKSPLASH PANEL INST. DETAIL
ENCLOSURE PANEL INSTALLATION DETAIL
ZERO CLEARANCE TO END OF HOOD
NOTES:
TO BE UL LISTED THERE MUST BE
SIDESPLASH PANELS MOUNTED THE FULL
WIDTH OF THE HOOD AGAINST THE
COMBUSTIBLE WALL
VERIFICATION OF HOOD HANGING HEIGHT ABOVE FINISHED FLOOR
(A.F.F.) IS REQUIRED FOR CORRECT PLACEMENT OF FIRE SYSTEM
NOZZLES.
HOOD HANGING HEIGHT FOR FIRE SYSTEMS
RECOMMENDED HANGING HEIGHT = 80" FROM
FINISHED FLOOR TO LOWER FRONT EDGE OF HOOD.
OTHER HANGING HEIGHT = __________" FROM
FINISHED FLOOR TO LOWER EDGE OF HOOD.
ON HOODS OVER 120"
HOOD HANGER BRACKET DETAIL
NOT TO SCALE
REFERENCE SCALED DRAWING FOR ACTUAL LOCATIONS
TYPICAL HOOD
HANGING METHOD
R a n g e
- 4 o r m o re b u rn e rs
F u e l T y p e : E le c tric
" L X
" W
X
" H
F ry e r - F u ll V a t w ith D rip b o a rd
F u e l T y p e : E le c tric
.5 " L
X
" W
X
" H
D u m p
S ta tio n
F u e l T y p e : E le c tric
.5 " L
X
" W
X
" H
G rid d le
F u e l T y p e : E le c tric
" L X
" W
X
" H
C o n v e c tio n O v e n
F u e l T y p e : E le c tric
" L X
" W
X
" H
MARK: Item 1 - Exhaust Hood - SECTION 1
ELEVATION VIEW
MARK: Item 1 - Exhaust Hood - SECTION 1
PLAN VIEW
46 IN. OC
F
IR
E S
Y S
T E
M M
A R
K It e m
C
F ir e S u p p re s s io n
MARK: Item 1 - Exhaust Hood
SECTION VIEW
169.0
FIXTURE TYPE
BULB / LAMP INFO
FOOT
CANDLES
TYPE / MODEL
MATERIAL
SIZE (IN.)
HOOD
NO.
ROUND LED
X-TRACTOR
STAINLESS STEEL
6.5 3.5 3.0
4.0 6.0
26.0
9.0 7.0
78.0 78.0
156.0 12.0 1.0
AIR SPACE
3.0
48.0
4.0
80.0
ABOVE
FINISHED
FLOOR
24.0
4.0
108.0
3.0
199.0 in. LENGTH
BACKSPLASH PANEL
9 26 0.562
26001 156 SINGLEXXEW-156-SITEM 1 - EXHAUST HOOD
4;394.184;MEDIUM
4;430 SS
WHERE
EXPOSED
LIGHTING DETAILS
QTY
L
GREASE FILTRATION DETAILS
QTY
H
LOCATION
UTILITY CABINET(S)
CONTROLS
HOOD INFORMATION
MARK FIRE SYSTEM
MODELTYPE SIZE INTERFACE
67.68
1 ITEM 1 - EXHAUST HOOD RIGHT ANSUL R102 XKC TOUCHSCREEN3
C O N S
TR
U C
TI
O N
C O M P L
IE
S
W
IT
H
N F P A
R R
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
STEINHART
23766
W.
YANR
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/2023
KCTCS - HCC FOOD SERVICE & CYBER CAFE
EXHAUST HOOD DRAWINGS
M5.1 Author
Checker
Designer
STANDARD
FIRE-WRAPPED
18 SQ
12 SQ
DUCT TYPE SIZE
WALL
26.00 SQ ∅ 28.88
51.75
(22.00)
13.25
See Table
22.50
SQ
26.00 SQ
Curb Cap
RECOMMENDED EXHAUST DUCT SIZE
SUGGESTED WALL OPENING
OVERALL HEIGHT MAY BE GREATER DEPENDING ON
MOTOR, ADAPTER, AND/OR HINGE BASE.
DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB.
CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE.
NOTE: SUGGESTED WALL OPENING WITH ROOF CURB - 26
One piece fully welded windband
Switch, NEMA-3R, Toggle, Shipped with Unit
Hinge, Factory Installed
High Temp Curb Seal Rated for Continuous Duty at 1500 F (Factory Attached)
Grease Pan Kit - Containment Configured for Wall-Mounted Applications (PN:879137)
Grease Trap (PN:475538)
Tapered bushing wheel hub
Breather tube outlet area min. 4.4 sq. in. (sizes 99-480), 2.0 sq. in. (sizes 60-95)
Min. windband material thickness: 0.051" aluminum (060-240), 0.064" aluminum (240HP, 240XP), 0.080" aluminum (sizes 300-480)
Larger Curb Cap Size - 26 Square
Sidewall Mounting - Fan Configured for Wall-Mounted Applications
Curb will be Through Wall, 12 in. Wall Thickness
UL/cUL 705 Listed - Supplement SC - "Power Ventilators for Restaurant Exh. Appliances" (Formerly UL 762)
MODEL
OPERATING
POWER (HP)
V/C/P ENCLOSURE
VOLUME
(CFM)
FAN
RPM
QTY
Direct Drive Upblast Centrifugal Wall Exhaust Fan
MOTORRPMWINDINGS NEC FLA*
MOTOR INFORMATION
SIZE (HP)
WEIGHT
(LB.)
MARK
TOTAL EXTERNAL SP
(IN WG)
MARK INFORMATION FAN INFORMATION
XCUE-160-VG 0.93 208/60/1 TF2,600 1,3521 1725 1 13.22138Item 1A - Exhaust Fan 1.25
Item 1A - Exhaust Fan : SELECTED OPTIONS AND ACCESSORIES
*NEC FLA - Based on table 430. 250 or 430. 248 of National Electrical Code 2020. Actual motor FLA may vary for sizing thermal overload, consult factory"
IT
E
M
A
E X
H A
U S
T F
A N
H E
N D
E R
S O
N C
O M
M U
N
IT
Y C
O L L E
G E
A C
C U
R E
X S
O U
T H
O H
K Y
I N
A A R O N
G E A R H A R T
A A
R O
N .G
E A
R H
A R
T
A C
C U
R E
X .C
O M
(5
)5
-5
P R
O J E
C T
M A
R K
/2
/2
22.00
25.50 25.50
C O N S
TR
U C
TI
O N
C O M P L
IE
S
W
IT
H
N F P A
R R
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
STEINHART
23766
W.
YANR
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/2023
KCTCS - HCC FOOD SERVICE & CYBER CAFE
EXHAUST FAN DRAWINGS
M5.2 Author
Checker
LINE 2
208V / 1PH
POWER FOR E1
MCA: 16.50
MOP: 25
LINE 1
GROUND 208V / 1PH
M
2 HP
13.2 FLA
DS1
6***
VARI-
GREEN
MOTOR
(ECM)
AI
COM
***REMOVE FACTORY
INSTALLED JUMPER
BETWEEN TERMINAL
5 AND 6 IF PRESENT
HOOD
LIGHTS
115VAC
1200W MAX
110V-120V / 1PH
POWER FOR
CONTROLS /
LIGHTS
(NON SHUNTED
15A BREAKER)
C2
NO2
NC2
COMMON
NORMALLY OPEN
NORMALLY CLOSED
FIRE SYSTEM
DRY
CONTACT 2*
UPON FIRE
OR NO POWER TO PANEL:
C TO NO WILL CLOSE
C TO NC WILL OPEN
LTS-H
LTS-N
GND
L
L
BLACK
WHITE
GREEN
DI-2A
DI-2B
DIGITAL IN 2
LIGHT ON/OFF
(DEFAULT)
C NO
DI-1A
DI-1B
DIGITAL IN 1
FAN ON/OFF
(DEFAULT)
C NO
(OPTIONAL ON/OFF INPUTS)
RS-A
RS-B
ROOM SENSOR
(SHIPPED LOOSE) 4.50
2.80
1.10
MOUNTING TYPE
FACTORY MOUNTED:
UTILITY CABINET - RIGHT END OF HOOD
USER INTERFACE CONTROL
FANS AND LIGHTS
INTERFACE CABLE LENGTH
7FT (FACTORY PROVIDED)
(INNER CONTROL BOX: 12 X 20 X 6)
ROOM SENSOR DETAILS
DRAWING NOT TO SCALE
MOUNTING TYPE
SHIP LOOSE:
SURFACE MOUNT
WIRING
BY OTHERS (USE 18/2)
4;CONTROLS
KITCHEN HOOD
NA
JOB NAME: HENDERSON COMMUNITY
COLLEGE
MODEL:
SERIAL NUMBER:
XKC-DCV-SR-10-1-1-0
WIRING DIAGRAM CODE:
MARK: ITEM 1B - CONTROLS
WDSN#
JOB NAME: HENDERSON COMMUNITY
COLLEGE
MODEL:
SERIAL NUMBER:
CAUTION
XKC-DCV-SR-10-1-1-0
THESE DRAWINGS SHALL NOT BE REMOVED FROM
THIS EQUIPMENT. USE COPPER CONDUCTORS
RATED TO 90°C UNLESS SPECIFIED. TORQUE
CONTROL & GROUND BLOCKS TO 8 LBS. IN.
TORQUE POWER LUGS/SCREWS TO COMPONENT
RATINGS LISTED. TORQUE CONTROL BOARD
SCREW TERMINALS TO 3.5 LBS. IN. FIELD CONTROL
WIRING RESISTANCE SHOULD NOT EXCEED 0.75
OHM. SEE IOM FOR ADDITIONAL INFORMATION, OR
CALL FACTORY AT 1-800-371-6858.
WIRING DIAGRAM CODE:
MARK: ITEM 1B - CONTROLS
WDSN#
ATTENTION
UNIT MUST BE GROUNDED IN ACCORDANCE
WITH N.E.C. POWER MUST BE OFF WHILE
SERVICING.
L’APPAREIL DOIT ÊTRE MIS À LA TERRE
CONFORMÉMENT AU CODE C.E. L’ALIMENTATION
DOIT ÊTRE COUPÉE DURANT L’ENTRETIEN.
NE PAS RETIRER CES DESSINS DE CET
ÉQUIPEMENT. SAUF INDICATION CONTRAIRE,
UTILISER DES CONDUCTEURS EN CUIVRE CLASSÉS
90 °C. SERRER LES BORNES DE COMMANDE ET DE
MISE À LA TERRE À 8 LB-PO. SERRER LES
COSSES/VIS D’ALIMENTATION AUX COUPLES
INDIQUÉS POUR LE COMPOSANT. SERRER LES
BORNES À VIS DE LA CARTE DE COMMANDE
À 3,5 LB-PO. LA RÉSISTANCE DU CÂBLAGE DE
COMMANDE LOCAL NE DOIT PAS DÉPASSER
0,75 OHM. POUR PLUS D’INFORMATION, CONSULTER
LE MANUEL OU APPELER 1-800-371-6858PRG VERSION: V4
FIELD WIRED (CÂBLÉ LOCALEMENT)
FACTORY WIRED (CÂBLÉ À L’USINE)
DOC NUMBER: ---- REV: ----
FACTORY SETTINGS
TYPE: VAV
CONFIGURATION: STANDARD
ZONES: 1
HOODS: 1
SUMPS: 0
EXHAUST FANS: 1
SUPPLY FANS: 0
MB ROOM SENSOR: YES
MB TEMP SENSORS: 1
HIGH TEMP FAULT: NO
FREEZE PROTECTION: YES
GAS RESET: NO
FAN PROVING: NO
BMS: NONE
ZONE SETTINGS
SEE ZONE CONFIGURATION IN TABLE ON LEFT
HOOD SETTINGS
SEE HOOD CONFIGURATION IN TABLE ON LEFT
EXHAUST FAN SETTINGS
SEE FAN CONFIGURATION IN TABLE ON LEFT
SUPPLY FAN SETTINGS 4;
SEE FAN CONFIGURATION IN TABLE ON LEFT
SENSOR SETTINGS
SEE HOOD CONFIGURATION IN TABLE ON LEFT
USER INTERFACE SETTINGS (MB) 4;
FAN & LIGHT BUTTONS: SHOW BOTH (SEPERATE)
USER INTERFACE SETTINGS (HCB)
NA
GENERAL SETTINGS 4;
TIME ZONE: CENTRAL DAYLIGHT (DEFAULT)
FIRE/FAULT SETTINGS 4;
EXHAUST DURING FIRE: MAX
SUPPLY DURING FIRE: OFF
LIGHTS DURING FIRE: OFF
BMS SETTINGS
DEFAULT SETTINGS /
PARAMÈTRES PAR DÉFAUT
PRG VERSION: V4
DRAWING NOT TO SCALE
CABINET DETAILS USER INTERFACE DETAILS
MOUNTING LOCATION:
UTILITY CABINET ON HOOD
NOTES:
1) WHEN CONTROLS ARE MOUNTED IN
HOOD-MOUNTED OR WALL-MOUNTED UTILITY
CABINET, FOR HOOD OR WALL CABINET
DIMENSIONS SEE HOOD SUBMITTAL.
2) MINIMUM OF 36" OF CLEARANCE
RECOMMENDED IN FRONT OF CONTROL CABINET
POWER WIRING FOR KITCHEN CONTROLS
43BM
COMMERCIAL APPLIANCE OUTLET CENTER
ELECTRICAL RATINGS: 110-240V,1PHASE, 50 -60HZ,15A
BASE FILE #E200616, ML FILE #E313951
SHUNT TRIP
(BY OTHERS)
WIRING EXAMPLE:
C1
NO1
COMMON
NORMALLY OPEN
APPLIANCE CONTACTORS
(BY OTHERS)
WIRING EXAMPLE:
HOT
NEUTRAL
SHUNT TRIP
BREAKER COIL
C1
NC1
COMMON
NORMALLY CLOSED
HOT
NEUTRAL
APPLIANCE
CONTACTOR COIL
*FIRE SYSTEM DRY CONTACT WIRING EXAMPLES
MAIN
CONTROL PANEL
CONTROL WIRING FOR KITCHEN CONTROLS
MB
(MAIN BOARD)
(WIRING TO BE DONE BY ELECTRICIAN) (WIRING TO BE DONE BY ELECTRICIAN,
IF NO CONTROLS CONTRACTOR.
USE 18-22GA WIRE UNLESS SPECIFIED.)
MAIN
CONTROL PANEL
(CONTINUED)
FS-C
FS-NC
C
NC
NO
FIRE SUPPRESSION
FIRE SYSTEM SWITCH
(REMOVE JUMPER IF USED)**
WILL BE
FACTORY
WIRED IF
MOUNTED
NEXT TO
FIRE SYSTEM
**WHEN FIRE SYSTEM IS
ARMED, FS-C TO FS-NC
SHOULD HAVE CONTINUITY
DOC NUMBER: ---- REV: ----
POWER WIRING FROM BREAKER
PANEL DIRECT TO FANS
BUILDING
BREAKER PANEL
(WIRING TO BE DONE BY ELECTRICIAN)
BUILDING
BREAKER PANEL
MAIN
CONTROL PANEL
H1 N1
GND
HOT
NEUTRAL
GROUND
C1
NO1
NC1
COMMON
NORMALLY OPEN
NORMALLY CLOSED
FIRE SYSTEM
DRY
CONTACT 1*
UPON FIRE
OR NO POWER TO PANEL:
C TO NO WILL CLOSE
C TO NC WILL OPEN
E1-S+ E1-S-
0-10VDC +
0-10VDC -
FAN SPEED
0-10VDC OUT
EXHAUST E1
MARK: ITEM 1A - EXHAUST FAN
EXHAUST E1
MARK:
ITEM 1A - EXHAUST
FAN
TS-1A
TS-1B
HOOD 1
TEMP SENSOR
HOOD MARK:
ITEM 1 - EXHAUST HOOD SECTION 1
WDC#
WDC#
IT
E
M
B
C O
N T
R O
LS
H E
N D
E R
S O
N C
O M
M U
N
IT
Y C
O
LL
E G
E A
C C
U R
E X
S O
U T
H O
H K
Y
IN
A A R O N
G E A R H A R T
A A
R O
N .G
E A
R H
A R
T
A C
C U
R E
X .C
O M
(5
)5
0-
P R
O
JE
C T
M A
R K
/2
/2
1 26001 EXHAUST E1 ITEM 1A - EXHAUST FAN 208 60 NO NO12FULL COLOR
TOUCHSCREEN
CABINET – RIGHT CABINET ON
ITEM 1 - EXHAUST HOODXKC-DCV-SR-10-1-1-0
RIGHT CABINET ON ITEM 1 -
EXHAUST HOODITEM 1B - CONTROLS
1 EXHAUST E1 ITEM 1A - EXHAUST FAN 2600 NO - - 5.0 10.0-1300Z1
1 H1 ITEM 1 - EXHAUST HOOD SECTION 1 Z1 E1 TS1 NO
1 Z1 MB-RS
ZONE CONFIGURATION
ZONE # ZONE ROOM TEMP
HOOD # HOOD HOOD MARK ZONE EXHAUST SUPPLY MB-TEMP SENSORS HCB
HOOD CONFIGURATION
FAN CONFIGURATION
FAN # TYPE FAN FAN MARK MAX CFM MODBUS VFD VFD ADDRESS MIN FREQ. MIN VDC MAX VDCMAX FREQ.MIN CFMZONE
FANS CONTROLLED
ZONE CFMFAN # TYPE FAN FAN MARK MOTOR VOLT CYCLE MOTOR STARTER IN PANEL VFD IN PANELMOTOR PHASEMOTOR HPTYPE
MARK
CONTROL INFORMATION
MODEL LOCATION
USER INTERFACE
LOCATION
ELECTRICAL CONTROL PACKAGE
CONTROL FEATURES
HOOD LIGHT CONTROL
TEMP SENSORS (FACTORY INSTALLED) - QTY. 1
ROOM SENSOR (SHIPPED LOOSE) - QTY. 1
DRY FIRE CONTACTS - QTY. 2
LIGHTS OFF DURING FIRE
EXHAUST MAX DURING FIRE
SUPPLY OFF DURING FIRE
C O N S
TR
U C
TI
O N
C O M P L
IE
S
W
IT
H
N F P A
R R
R E
NI
GNEAN LOIS
ES
F O R P
E
KENTUC
K Y
FO
ETAT
S
DESNE
L I C
STEINHART
23766
W.
YANR
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
AS BUILT DATE MM/DD/YR
DRAWN BY
A&E FILE NO. 2301-123
DECA LOG #
ACCOUNT NO.
470 CAXV HN 2901
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
10/16/2023
KCTCS - HCC FOOD SERVICE & CYBER CAFE
CONTROLS DRAWINGS
M5.3 Author
Checker
ANSUL R102 (WET CHEMICAL) FIRE PROTECTION SYSTEM - MODEL FSSC
NC
NO
SHUNT TRIP BREAKER
POWER TO
COOKING EQUIPMENT
ELECTRIC GAS VALVE - IF RESET RELAY IS USED
SEE OPTION A OR B AT RIGHT, MECHANICAL
GAS SHUT OFF VALVE DOES NOT REQUIRE
ELECTRICAL CONNECTION.
CONNECTION TO COOKING
EQUIPMENT SHUT DOWN
METHOD OF WIRING, IF PROHIBITED BY LOCAL CODES.
DO NOT SHUT DOWN EXHAUST FANS WITH THIS
NC
NO
FAN(S)
N } INPUT
120 VAC
POWER TO
FAN
STARTER
MANUAL SWITCH
CONNECTION TO FAN SHUT DOWN
N } INPUT
120 VAC
NC
NO
NC
VOLTAGE FREE
BUILDING ALARM(S)
CONTACTS FORINPUT
NO
CONNECTION TO BUILDINGS ALARM
3 4
IT
E
M
C
F
IR
E S
U P
P R
E S
S
IO
N
H E
N D
E R
S O
N C
O M
M U
N
IT
Y C
O L L E
G E
A C
C U
R E
X S
O U
T H
O H
K Y
I N
A A R O N
G E A R H A R T
A A
R O
N .G
E A
R H
A R
T
A C
C U
R E
X .C
O M
(5
)5
-5
P R
O J E
C T
M A
R K
/2
/2
IT
E
M
C
F
IR
E S
U P
P R
E S
S
IO
N
H E
N D
E R
S O
N C
O M
M U
N
IT
Y C
O L L E
G E
A C
C U
R E
X S
O U
T H
O H
K Y
I N
A A R O N
G E A R H A R T
A A
R O
N .G
E A
R H
A R
T
A C
C U
R E
X .C
O M
(5
)5
-5
P R
O J E
C T
M A
R K
/2
/2
SUPPLY
LINE
DETECTION MARK(S) PROTECTED BY FIRE SYSTEM
FIRE SYSTEM OPTIONS AND ACCESSORIES
FULL INSTALLATION (INCLUDES PRE-PIPED HOOD(S) WITH DETECTION AND FACTORY COORDINATED INSTALL)
CHROME SLEEVES FOR FACTORY PROVIDED APPLIANCES DROPS - INCLUDED
METAL BLOW-OFF CAPS - INCLUDED
HOOD SUPPRESSION TANK - INCLUDED - 3 GAL. - [(1) 3.0 TANK(S)]
REMOTE PULL STATION - STANDARD - FIELD INSTALLATION AT SINGLE POINT OF EGRESS
CONTINUOUS FUSIBLE LINK
ANSUL R-102
WET CHEMICAL
11 UTILIZED
11 AVAILABLE
CABINET – RIGHT END OF ITEM 1 -
EXHAUST HOOD
ITEM 1C - FIRE SUPPRESSION
1. STAINLESS STEEL ENCLOSURE
2. AGENT STORAGE TANK
3. EXPELLENT GAS CARTRIDGE
4. ANSUL AUTOMAN RELEASE
5. REGULATOR
6. KNOCKOUT FOR WIRING MICROSWITCH
CONTROL PANEL
WET CHEMICAL FIRE PROTECTION SYSTEM TO BE ANSUL R-102, DESIGNED IN
COMPLIANCE WITH UL 300 REQUIREMENTS.
-VERIFICATION OF ALL COOKING EQUIPMENT MAKE, MODEL AND LOCATION
REQUIRED FOR ALL FIRE PROTECTION SYSTEMS.
-ALL FIRE SYSTEM PIPING IS STANDARDLY TO THE RIGHT END OF THE HOOD
UNLESS A WALL IS LOCATED ON THE RIGHT END.
-ANSUL AUTOMAN RELEASE TO BE LOCATED WITHIN 60" OF HOOD.
THE BASIC FIRE SYSTEM WILL INCLUDE THE FOLLOWING:
-GAS SHUT-OFF VALVE, IF REQUIRED, TO BE SUPPLIED BY MANUFACTURER (UP
TO 2" DIAMETER AS STANDARD), AND INSTALLED BY A LICENSED PLUMBER.
-MICRO SWITCH TO BE SUPPLIED BY MANUFACTURER FOR CONNECTION TO,
BUT NOT LIMITED TO, BUILDING ALARM SYSTEM(S), EXHAUST AND SUPPLY
FANS AND ELECTRICAL POWER SHUT DOWN. FIELD WIRING AND CONNECTIONS
TO BE PERFORMED BY A LICENSED ELECTRICIAN.
THE BASIC FIRE SYSTEM DOES NOT INCLUDE THE FOLLOWING:
-FULL DUMP TEST OTHER THAN WHT IS SPECIFIED PER THE INSTALLATION
MANUAL, OR TO SATISFY A STATE OR LOCAL CODE. PERMIT AND TESTING
FEES ARE NOT INCLUDED UNLESS NOTED UNDER THE EQUIPMENT SCHEDULE
FOR THE FIRE SYSTEM.
-MORE THEN TWO TRIPS TO THE JOBSITE OR SPECIAL TRANSPORTATION, OR
OVERNIGHT LODGING REQUIREMENTS IN REMOTE AREAS. NORMAL TRAVEL
DISTANCE IS FIRST 50 MI. (80.5 KM) FROM OFFICE.
- SPECIAL CLASSES OR ADDITIONAL LABOR FOR ACCESS TO SECURITY
SENSITIVE AREAS.
-INSTALLATION OF GAS SHUT-OFF VALVE.
-SPECIAL DRAWINGS REQUIRED TO SATISFY STATE OR LOCAL CODE. PLAN
EXAMINATION FEES, PE OR FS APPROVAL STAMP.
-UNION LABOR, GOVERNMENT LABOR, OR PREVAILING WAGES REQUIRED FOR
FINAL FIELD HOOK-UP.
-ANY AND ALL ELECTRICAL COMPONENTS/CONNECTIONS REQUIRED TO SHUT
DOWN FANS, SHUT OFF DEVICE FOR ELECTRIC COOKING EQUIPMENT (SHUNT
TRIP BREAKER), OR ACTIVATE AN ALARM SYSTEM, ETC.
-ANY DISMANTLING OR REASSEMBLY REQUIRED TO GAIN ACCESS TO THE FIRE
SUPPRESSION PIPING LOCATED ON THE TOP OF THE HOOD.
-ROUGH-IN HIDDEN CONDUIT FOR REMOTE PULL STATION OR GAS VALVE
(FLUSH MOUNTED PULL STATION).
-INSTALLATION OF MORE THAN (1) REMOTE PULL STATIONS OR DISTANCES
GREATER THAN 20 FT (6.1M.)
-PARTS OR LABOR REQUIRED TO CORRECT PIPING DUE TO COOKING
EQUIPMENT CHANGES OR DEVIATION FROM PLANS. OR ANY CHARGES FOR
MISSING OR ADDITIONAL PARTS OTHER THEN THOSE INDICATED ON THE FIRE
SUPPRESSION DETAIL.
NOTES:
NOT TO SCALE
NOTES:
1.
2.
3. DO NOT USE BLACK WIRE ON SNAP-ACTION SWITCH IN
NORMAL INSTALLATION. BLACK WIRE TO BE USED ONLY
FOR EXTRANEOUS ALARM, LIGHT CIRCUITS, ETC.
DPDT SWITCHES PROVIDED BY MANUFACTURER MAY BE
WIRED PER TYPICAL EXAMPLES SHOWN. VERIFY WITH
LOCAL CODES AND EQUIPMENT SUPPLIED AS THE
CONNECTION NEEDED FOR YOUR INSTALLATION.
WIRING…