This is an Addendum (No. 02) issued by the Commonwealth of Kentucky's Department for Facilities and Support Services, Division of Engineering and Contract Administration, for the Ravenna Readiness Center Envelope Restoration project (Invitation to Bid No. RFB-35-26). The addendum, dated August 12, 2025, provides clarifications and modifications to the original bid documents for the Department of Military Affairs project located in Revenna, Kentucky. Key modifications include removing existing concrete stairs and landings, specifying new concrete stairs, detailing laminated copper flashing requirements, clarifying window system construction using storefront materials, and removing references to ballistic and bullet resistance in specifications.
The addendum also outlines specific technical requirements for storm water management, including installing 8" schedule 40 PVC pipes below grade from six downspouts on the front and side of the building, with back-of-building downspouts discharging to an existing flume. Pavement patch repairs using new blacktop are to match existing thicknesses. Additional site visits are not available prior to the bid date, and bidders are required to acknowledge receipt of this addendum in their proposal. The document is issued by alt32 Architecture | Design from Lexington, Kentucky, and provides comprehensive guidance for contractors bidding on this restoration project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-35-26
FOR: Envelope Restoration Ravenna Readiness Center Department of Military Affairs Revenna, Kentucky
DATE: August 12, 2025
RFB-785-2600000036
ADDENDUM NO. Two (2)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-35-26 For: Envelope Restoration Ravenna Readiness Center Department of Military Affairs Revenna, Kentucky
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
ADDENDUM NO. 02
August 12, 2025
To: All Plan holders
From: alt32 Architecture | Design 310 Old Vine Street, Suite 300 Lexington, KY 40507-1534
Re: RFB-35-26 DMA Ravenna RC Envelop Restoration
This addendum is one (2) Page of 8-1/2 x 11.
The purpose of this addendum is to clarify further the requirements of the contract documents. The contractors are governed by the information in the addendum as the content becomes part of the contract documents. The bidders shall acknowledge receipt of the addendum in their form of proposal.
Items:
1. Additional Site Visits are not available prior to the Bid Date.
2. Clarification: Details 1/A5 and 2/A5 on sheet “A5 - CONCRETE STEPS ENLARGED PLAN / ELEVATIONS”, where it indicates that a portion of the existing concrete is to remain, disregard. Remove existing concrete stairs and landings complete. Provide new concrete stairs and landings. Ensure new concrete allows for flush condition at building entrances.
3. Clarification: Basis for Design for Laminated Copper Flashing is as follows:
Hohmann & Barnard’s Copper-Fabric™ NA Copper Fabric Flashing 7oz.
Reference drawing 1/A6, 9/A6, and 15/A6. Use at all locations where new flashing is required.
4. Clarification: Details 5/A6 and 6/A6 on Sheet A6; Window systems to be constructed and assembled out of storefront material.
5. Reference specification section 085653 Exterior Security Windows:
1.1 A. : Reference to “bullet” shall be stricken from the specifications.
1.5 - A – 1 and 5: Reference to UL 752 Ballistic shall be stricken from the specifications
2.3 F. : Reference to “bullet” shall be stricken from the specifications.
The design intent to is to delete all reference to ballistic and bullet resistance. The intent is for the designated windows and storefronts to conform to blast resistance.
6. Reference the previously published addendum 1. The design intent is the capture all storm water from the existing downspouts and pipe below grade to the existing culvert at the road. Thus:
Provide and install new 8” schedule 40 PVC pipe below grade from all downspouts on the front and side of the building - total 6. Provide new "boot" transition at the bottom of the downspouts to the new pipe.
Downspouts on the back of the building will discharge to the existing flume similar to existing.
Patch repair the pavement. with new blacktop patch. Match existing thickness(es)
End of Addendum