Addendum One .pdf
PDF 4 MB Posted
- Attached to
- RFB-166-26 DOC KSP Security Fence Addition
- Solicitation number
- RFB 785 2600000294 3
- Issued by
- Leslie County, Kentucky
About this file
This is Addendum One to Invitation to Bid No. RFB-166-26 issued by the Commonwealth of Kentucky Department for Facilities and Support Services, Division of Engineering and Contract Administration, for a Security Fence Addition project at the Kentucky State Penitentiary in Eddyville, Kentucky. The addendum, dated January 6, 2026, modifies the original Project Manual and Construction Drawings dated November 21, 2025, and must be acknowledged by bidders in their proposals to avoid disqualification. The project involves repair and addition work to the existing prison stone wall, including stone masonry repair and repointing, high-security chain link fences and gates, concrete cap repairs, and structural patching. Key modifications include the addition of Sections 040342 (Historic Stone Masonry Repair) and 040343 (Historic Stone Masonry Repointing) to the specifications, revision of fence height specifications to read "as indicated on Drawings," and complete replacement of all structural drawings. The repair schedule identifies specific quantities of work including 3,060 stone repairs on the inside north wall, 26,700 linear feet of repointing, 5,940 square feet of concrete cap spall repair, and 637 square feet of concrete cap crack repair across the east, west, and north prison stone walls.
The addendum establishes detailed contractor responsibilities and requirements for field verification of all dimensions and existing conditions prior to fabrication or material ordering, with the contractor bearing sole responsibility for design adequacy and safety of temporary supports, bracing, and shoring. All shop drawing submittals for structural items, including stone repair mortars, concrete repair mortars, epoxy, concrete joint sealants, and elevation drawings, must be submitted to the architect prior to fabrication or construction. The contractor must coordinate all work with the owner's safety and security protocols given the facility will remain operational during construction, and must notify the engineer of any field conditions differing from those shown in structural documents. The specifications provide contractors with options for stone repair methods including complete replacement, "Dutchman" stone repair, or stone repair mortar application, with the repair method selection at the contractor's discretion.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum Two.pdf | ||
| Final_RFB_785_2600000294_2_SO_FORM.PDF | ||
| Final_RFB_785_2600000294_1_SO_FORM.PDF | ||
| Final_RFB_785_2600000294_3_SO_FORM.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-166-26
FOR: Security Fence Addition Kentucky State Penitentiary Department of Corrections Eddyville, Kentucky
DATE: January 6, 2026
RFB-785-2600000294
ADDENDUM NO. One (1)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to attached addendum for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-166-26 For: Security Fence Addition Kentucky State Penitentiary Department of Corrections Eddyville, Kentucky
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
D i f f erent by Des i gn – B u i l t on Expe r i enc e
SECURITY FENCE ADDITION
Kentucky State Penitentiary 266 Water Street Eddyville, KY 42038
Addendum Number One
05 January 2026
Project #: 527-CAL7-SR50-00
TO ALL BIDDERS OF RECORD AND ALL REGULATORY AGENCIES
This Addendum forms part of the Contract Documents and modifies the Project Manual and the Construction Drawings dated 21 November 2025. Acknowledge receipt of this Addendum in Proposal. Failure to do so may subject Bidder to disqualification.
1.1 Reference: Specifications
A. Section 040342 – Historic Stone Masonry Repair
1) Add Section 040342 to Project Manual.
B. Section 040343 – Historic Stone Masonry Repointing
1) Add Section 040342 to Project Manual.
C. Section 323113.53 - High-Security Chain Link Fences and Gates
1) Revise Paragraph 2.3.A.1 to read Fence Height: As indicated on Drawings.
1.2 Reference: Drawings
Structural Drawings – Replace all structural drawings in their entirety.
A. Sheet S001 – General Notes
1) Revise notes.
B. Sheet S101 – Existing Stone Wall Repair Plan
1) Revise column heading on Repair Schedule
2) Revise repair schedule note 2.
3) Add repair schedule note 7.
C. Sheet S102 – Existing Stone Wall Repair
1) No revisions.
D. Sheet S103 – Existing Stone Wall Repair Details
1) Photo 2 – revise stone “replacement” keynote with stone repair.
2) Revise notes.
Shane D Wiles, AIA, LEED AP BD+C Architect 713 Architects, PLLC
1) GENERAL NOTES
a) SUBMITTALS
i) SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO ANY
FABRICATION OR CONSTRUCTION FOR ALL STRUCTURAL ITEMS, INCLUDING THE
FOLLOWING: STONE REPAIR MORTARS, CONCRETE REPAIR MORTARS, EPOXY,
CONCRETE JOINT SEALANT, ELEVATION DRAWINGS SHOWING STONES TO BE
REPAIRED.
2) MISCELLANEOUS
a) NO CHANGE IN SIZE OF STRUCTURAL ELEMENTS OR MODIFICATION THEREOF SHALL BE
MADE, NOR ARE ANY OPENINGS OR SLEEVES THROUGH ANY STRUCTURAL ELEMENTS
PERMITTED, UNLESS DETAILED ON THE STRUCTURAL DRAWINGS.
b) NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER SPECIFICATIONS, GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE SHOWN FOR SIMILAR WORK.
3) CONTRACTOR RESPONSIBILITIES
a) MATERIAL, WORKMANSHIP, AND DESIGN SHALL CONFORM TO THE BUILDING CODE.
b) CONTRACT DRAWINGS ARE CONSIDERED TO BE PART OF THE CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW AND COORDINATION OF
ALL THE DRAWINGS AND SPECIFICATIONS PRIOR TO THE START OF CONSTRUCTION.
ANY DISCREPANCIES THAT OCCUR SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT/ENGINEER PRIOR TO THE START OF CONSTRUCTION SO THAT A
CLARIFICATION CAN BE ISSUED. ANY WORK PERFORMED IN CONFLICT WITH THE
CONTRACT DOCUMENTS OR ANY CODE REQUIREMENTS SHALL BE CORRECTED BY THE
CONTRACTOR AT THEIR OWN EXPENSE AND AT NO EXPENSE TO THE OWNER OR
ARCHITECT/ENGINEER.
c) VERIFY THE DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING
WORK. ANY DISCREPANCY BETWEEN SUCH DETAILS AND DIMENSIONS AS MAY OCCUR
SHALL BE REPORTED TO THE ARCHITECT/EOR FOR CLARIFICATION BEFORE
PROCEEDING WITH THE WORK.
d) DUE TO THE NATURE OF THE WORK, ALL DIMENSIONS AND/OR EXISTING DETAILS
SHOWN ON THE DRAWINGS THAT WILL IN ANY WAY AFFECT THE WORK SHALL BE
FIELD-VERIFIED PRIOR TO FABRICATION OF ANY MATERIALS. FIELD-VERIFICATION
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. IF THERE IS ANY QUESTION TO
THE INTENT OF THE WORK INDICATED, THE CONTRACTOR SHALL CLEAR THE QUESTION
WITH THE ARCHITECT/EOR.
e) THE CONTRACTOR SHALL BE AWARE THAT THE WORK INVOLVES REPAIR TO AN
EXISTING FACILITY THAT WILL REMAIN IN OPERATION DURING CONSTRUCTION. IT IS
THEREFORE MANDATORY FOR WORK THAT WILL IN ANY WAY AFFECT THE NORMAL
OPERATION OF THE FACILITY BE COORDINATED WITH THE OWNER.
f) NOTIFY, IN WRITING, THE ENGINEER OF CONDITIONS ENCOUNTERED IN THE FIELD
DIFFERENT FROM THOSE SHOWN IN THE STRUCTURAL DOCUMENTS.
g) THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE
FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE
CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY SHALL INCLUDE, BUT NOT
BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT,
ETC. OBSERVATION VISITS TO THE SITE BY THE ENGINEER SHALL NOT INCLUDE
INSPECTION OF THE ABOVE ITEMS.
h) CONTRACTOR HAS SOLE RESPONSIBILITY FOR THE DESIGN, ADEQUACY, AND SAFETY
OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC.
i) CONTRACTOR HAS SOLE RESPONSIBILITY TO COMPLY WITH ALL OSHA SAFETY
REGULATIONS.
j) CONTRACTOR SUBMITTALS/SHOP DRAWINGS
i) DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE ENGINEER; THEREFORE, THEY SHALL BE VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL REVIEW AND
STAMP THE DRAWINGS FOR CONFORMANCE WITH THE MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND OPERATIONS OF CONSTRUCTION, AND ALL SAFETY
PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO.
ii) SHOP DRAWINGS SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE
ORDERS. THE PURPOSE OF SHOP DRAWINGS SUBMITTALS IS TO DEMONSTRATE TO
THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, BY
INDICATING WHICH MATERIAL IS INTENDED TO BE FURNISHED AND INSTALLED,
AND BY DETAILING THE INTENDED FABRICATION AND INSTALLATION METHOD. IF
ANY DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP DRAWINGS AND
THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP
DRAWING SUBMITTALS ARE PROCESSED BY THE ENGINEER, THE CONTRACT
DRAWINGS AND SPECIFICATIONS SHALL CONTROL AND SHALL BE FOLLOWED.
iii) REVIEW OF SUBMITTALS OR SHOP DRAWINGS BY THE ENGINEER DOES NOT
RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW AND CHECK
ALL SUBMITTALS AND SHOP DRAWINGS BEFORE SUBMITTING TO THE STRUCTURAL
ENGINEER. CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR THE ERRORS AND
OMISSIONS ASSOCIATED WITH THE PREPARATION OF SUBMITTALS AND SHOP
DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS
SPECIFIED IN THE CONTRACT DOCUMENT.
iv) DIMENSIONS NOTED AS PLUS OR MINUS (±) INDICATE UNVERIFIED DIMENSIONS
AND ARE APPROXIMATE. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS OR
EXCESSIVE VARIATIONS FROM INDICATED DIMENSIONS. NOTED DIMENSIONS TAKE
PRECEDENCE OVER SCALED DIMENSIONS–DO NOT SCALE DRAWINGS. DIMENSIONS
OF EXISTING CONDITIONS MAY BE BASED ON RECORD DRAWINGS AND ARE TO BE
FIELD-VERIFIED BY THE CONTRACTOR.
RTA DATERTA DATE
DECA LOG #DECA LOG #
A&E FILE NO.A&E FILE NO.
CHECKED BYCHECKED BY
DRAWN BYDRAWN BY
DRAWING DATEDRAWING DATE
DRAWING INFORMATIONDRAWING INFORMATION
DRAWING NO.DRAWING NO.
AS BUILT DATEAS BUILT DATE
DATEDATEDESCRIPTION OF REVISIONSDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWINGREVISION HISTORY OF THIS DRAWING
DATEDATEDESCRIPTION OF REVISIONSDESCRIPTION OF REVISIONS
527-CAL7-SR50-00527-CAL7-SR50-00
COMMONWEALTH OF KENTUCKYCOMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINETFINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICESDEPARTMENT FOR FACILITIES AND SUPPORT SERVICES DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATIONDIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKYFRANKFORT, KENTUCKY
713 Architects, PLLC 9700 Park Plaza Avenue Suite 201 Louisville, KY 40241
500 W Jefferson Street, Suite 2200 Louisville, KY 40202 O: 502.325.0100 www.kpff.com
AS BUILT DATEAS BUILT DATE
S001
GENERAL NOTES
KENTUCKY STATE PENITENTIARY
SECURITY FENCE ADDITION
11/22/24
JP
YL
2200416
ADDENDUM 1 01/05/2026
1/5/
(E) STONE WALL TO BE REPAIRED
-APPOXIMATELY 20 FT TALL
CELL HOUSE #3
GUN TOWER @2
49'-4 3/4"
CELL HOUSE #6
BLDG #2
BLDG #1
ANNEX
CELL HOUSE #4
CELL HOUSE #5
CONTROL ROOM
GUN TOWER #4
222'-0 1/4"
GUN TOWER #5
GUN TOWER #6
440'-0''
(E)
GATE
(E)
GATE
GUN TOWER #3
GUN TOWER #8
GUN TOWER #7
209'-0" 245'-9 5/8"
4'
-5
/8
2'
-3
9'
-3
/8
70'-0" 440'-0''
WEST PRISON STONE
WALL
EAST PRISON STONE
WALL
0'
-0
N O
R
TH
NORTH PRISON STONE
WALL
LENGTH OF WALL DIMENSIONS ARE +/-, VERIFY IN FIELD
REPAIR SCHEDULE
SIDE
INSIDE
OUTSIDE
OUTSIDE
WALL
EAST
EAST
NORTH
CAP
JOINT
(LF)
PHOTO
3/S103
CONC CAP
SPALL (SF)
PHOTO
3/S103
CONC. CAP
CRACK (LF)
PHOTO
4/S103
3060INSIDE
NORTH
STONE
"REPAIR"
(EA.)
PHOTO
2/S103
1.
2.
3.
4.
5.
6.
7.
A.
B.
C.
REPOINT JOINT: 1/2'' THICK X4'' DEEP
FOR BIDDING PURPOSES ASSUME STONE REPAIR IS 4'' DEEP. EXISTING STONES ARE APPROX. 2 FT HIGH X 3 FT WIDE .
CAP JOINT; SAW-CUT 3/8'' WIDE DP. GROOVE IN TOP OF (E) CAP INSTALL BACKER ROD & SEALANT. DETAIL 6/S103 CONC. CAP SPALL: CUT OUT DETERIORATED CONCRETE PER TYPICAL REPAIR DETAIL AND PLACE STRUCTURAL PATCHING MATERIAL. DETAIL 8/S103
CRACK - EPOXY INJECT
ALL WORK TO BE COORDINATED AND PERFORMED IN ACCORDANCE WITH THE OWNER'S SAFETY AND SECURITY PROTOCOL.
"STONE REPAIR" - SPECIFICATIONS PROVIDE THREE DIFFERENT WAYS TO REPAIR THE STONE:
COMPLETE REPLACEMENT
"DUTCHMAN"
STONE REPAIR MORTAR
THE REPAIR METHOD IS AT THE CONTRACTOR'S OPTION
NOTES
WEST
WEST
INSIDE
OUTSIDE
REPOINT
(SF).
PHOTO
1/S103
TOTAL 26700 14 310 1535
NOTE:
1. VERIFY MEASUREMENTS AND CONDITIONS IN THE FIELD.
CONC CAP VOID (CF)
PHOTO 5/S103
SCALE: 1" = 40'-0"
EXISTING PRISON STONE WALL REPAIR PLAN1
RTA DATERTA DATE
DECA LOG #DECA LOG #
A&E FILE NO.A&E FILE NO.
CHECKED BYCHECKED BY
DRAWN BYDRAWN BY
DRAWING DATEDRAWING DATE
DRAWING INFORMATIONDRAWING INFORMATION
DRAWING NO.DRAWING NO.
AS BUILT DATEAS BUILT DATE
DATEDATEDESCRIPTION OF REVISIONSDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWINGREVISION HISTORY OF THIS DRAWING
DATEDATEDESCRIPTION OF REVISIONSDESCRIPTION OF REVISIONS
527-CAL7-SR50-00527-CAL7-SR50-00
COMMONWEALTH OF KENTUCKYCOMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINETFINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICESDEPARTMENT FOR FACILITIES AND SUPPORT SERVICES DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATIONDIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKYFRANKFORT, KENTUCKY
713 Architects, PLLC 9700 Park Plaza Avenue Suite 201 Louisville, KY 40241
500 W Jefferson Street, Suite 2200 Louisville, KY 40202 O: 502.325.0100 www.kpff.com
AS BUILT DATEAS BUILT DATE
S101
EXISTING STONE WALL REPAIR PLAN
KENTUCKY STATE PENITENTIARY
SECURITY FENCE ADDITION
11/22/24
JP
YL
2200416
ADDENDUM 1 01/05/2026
RTA DATERTA DATE
DECA LOG #DECA LOG #
A&E FILE NO.A&E FILE NO.
CHECKED BYCHECKED BY
DRAWN BYDRAWN BY
DRAWING DATEDRAWING DATE
DRAWING INFORMATIONDRAWING INFORMATION
DRAWING NO.DRAWING NO.
AS BUILT DATEAS BUILT DATE
DATEDATEDESCRIPTION OF REVISIONSDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWINGREVISION HISTORY OF THIS DRAWING
DATEDATEDESCRIPTION OF REVISIONSDESCRIPTION OF REVISIONS
527-CAL7-SR50-00527-CAL7-SR50-00
COMMONWEALTH OF KENTUCKYCOMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINETFINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICESDEPARTMENT FOR FACILITIES AND SUPPORT SERVICES DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATIONDIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKYFRANKFORT, KENTUCKY
713 Architects, PLLC 9700 Park Plaza Avenue Suite 201 Louisville, KY 40241
500 W Jefferson Street, Suite 2200 Louisville, KY 40202 O: 502.325.0100 www.kpff.com
AS BUILT DATEAS BUILT DATE
S102
EXISTING STONE WALL REPAIR
KENTUCKY STATE PENITENTIARY
SECURITY FENCE ADDITION
11/22/23
JP
YL
2200416
EAST WALL (INTERIOR) LOOKING NORTH1 EAST WALL (INTERIOR) LOOKING SOUTH2 NORTH WALL (INTERIOR) LOOKING WEST3 NORTH WALL (INTERIOR) LOOKING EAST4
WEST WALL (INTERIOR) LOOKING SOUTH5 WEST WALL (INTERIOR) LOOKING NORTH6 NORTH WALL (EXTERIOR) LOOKING SOUTHEAST7 WEST WALL (EXTERIOR) LOOKING NORTH8
WEST WALL (EXTERIOR) LOOKING SOUTH9 EAST WALL (EXTERIOR) LOOKING SOUTH10
NOTES:
1. SOUND CONCRETE BY CHAIN-DRAG TO LOCATE THE AREA OF UNSOUND/ DELAMINATION.
2. MARK PERIMETER OF REPAIR AREA ABOUT 2" BEYOND THE LOCATED UNSOUND/DELAMINATED AREA.
LAYOUT SHOULD BE SIMPLE GEOMETRIC SHAPE.
3. SAW-CUT PERIMETER OF REPAIR AREA 1/2" DEEP. DO NOT CUT (E) REINFORCING.
4. REMOVE LOOSE OR DELAMINATED CONCRETE WITH 15-LB MAX CHIPPING HAMMER ABOVE
OXIDIZED/CORRODED REINFORCING STEEL. ONCE INITIAL REMOVAL IS MADE, PROCEED WITH THE
UNDERCUTTING OF ALL EXPOSED OXIDIZED/CORRODED REINF. UNDERCUTTING IS TO PROVIDE
CLEARANCE FOR UNDER-BAR CLEANING, FULL REINF CIRCUMFERENCE BONDING TO SURROUNDING CONCRETE, AND TO SECURE THE PATCH STRUCTURALLY. PREPARE, AND IF REQUIRED, REPLACE REINF.
AS SPECIFIED.
5. PROVIDE MINIMUM 3/4" CLEARANCE BETWEEN EXPOSED REINF. AND SURROUNDING
CONCRETE OR 1/4" LARGER THAN THE LARGEST AGGREGATE SIZE IN THE REPAIR MIXTURE, WHICHEVER
IS GREATER.
6. CONCRETE REMOVAL SHALL EXTEND ALONG THE REINF. TO LOCATIONS ALONG THE REINF
FREE OF BOND INHIBITING CORROSION, AND WHERE THE REINF. IS WELL BONDED TO
SURROUNDING CONCRETE. SHOULD THE DEMOLISHED AREA EXCEED THE MARKED BOUNDARY, THE
NEW PERIMETER SHALL RECEIVE SAW CUT AS SPECIFIED ABOVE.
7. IF UNOXIDIZED REINFORCING STEEL IS EXPOSED DURING THE UNDERCUTTING PROCESS,
CARE SHALL BE TAKEN NOT TO DAMAGE THE REINFORCINGS BOND TO SURROUNDING CONCRETE.
IF BOND BETWEEN REINF. AND CONCRETE IS BROKEN, UNDERCUT REINF IN ACCORDANCE WITH THE
NOTES ABOVE.
8. ANY REINFORCEMENT WHICH IS LOOSE SHALL BE SECURED IN PLACE BY TYING TO OTHER
SECURED REINF OR BY ANCHORING EPOXY SET OF 1/4" Ø STAINLESS STEEL HOOK BARS
SPACED AT 12" MAXIMUM CENTERS.
9. WHERE PATCH DEPTH EXCEEDS 2",INSTALL 6X6-W4.0XW4.0 (58#) EPOXY COATED STEEL MESH IN THE PATCHED AREA WITH MINIMUM OF 1 1/2" COVER FROM TOP AND 3/4" FROM BOTTOM OF THE PATCH.
UNSOUND/DELAMINATED
EXISTING CONCRETE
A
LL
A R O
U N
D 1/
2" S
A W
C U
T
EXISTING
REINF.
SAW CUT AND REMOVE THE UNSOUND
CONCRETE.EXISTING
STONE
CONCRETE SURFACE PREPARATION & REPAIR DETAIL
EXISTING
CONCRETE CAP
2'' +/- TYP
(E) CONC. CAP
SAW-CUT JOINT 3/8" WIDE X 1"
DEEP, INSTALL BACKER ROD
AND SEALANT. EXTEND JOINT
AND SEALANT ALONG THE
SIDES OF CAP.
TOP OF CAP
TYPICAL CONCRETE REPAIR NOTES:
CRACK REPAIR:
PREPARE SUBSTRATE AND APPLY REPAIR PRODUCT AS PER MANUFACTURER
RECOMMENDATION/INSTRUCTION.
NON-STRUCTURAL CRACKS: HAIR LINE AND RANDOM CRACKS LESS THAN OR EQUAL TO 1/16" WIDE
THAT DOES NOT PENETRATE THE FULL THICKNESS OF THE CONCRETE
STRUCTURAL CRACK: ANY CRACK WIDER THAN 1/16" OR ANY CRACK THAT PENETRATES THE FULL
DEPTH OF THE CONCRETE.
A. HORIZONTAL NON-STRUCTURAL CRACK: ROUT & SEAL PER 7/S103
B. HORIZONTAL STRUCTURAL CRACK: PRESSURE INJECT CRACKS WITH EPOXY ADHESIVE. SET
INJECTION PORTS PER MANUFACTURER RECOMMENDATIONS. SEAL PORTS AND CRACKS
WITH EPOXY GEL.
C. VERTICAL NON-STRUCTURAL CRACK: ROUT AND SEAL PER DETAIL 7/S103
D. VERTICAL STRUCTURAL CRACK: REPAIR SAME AS HORIZONTAL STRUCTURAL CRACK.
E. GRIND SMOOTH PORTS AFTER EPOXY SETS.
VERTICAL SURFACE CONCRETE REPAIR:
A. SOUND AND PREPARE SURFACE SIMILAR TO 8/S103.
B. PRIME REINFORCEMENT WITH 2 COATS OF REINFORCEMENT RUST INHIBITOR. APPLY PER
PRODUCT DATA SHEET AND MANUFACTURERS INSTRUCTION. DO NOT APPLY TO THE
CONCRETE SUBSTRATE.
C. APPLY SCUB COAT OF CONCRETE REPAIR MORTAR (FOR VERTICAL REPAIR) INTO PREPARED
SURFACE AND WHILE THE SCUB COAT IS STILL WET APPLY THE CONCRETE REPAIR MORTAR
PER MANUFACTURER'S RECOMMENDATIONS.
FOR HORIZONTAL SURFACE CONCRETE REPAIR:
A. SOUND AND PREPARE SURFACE PER 8/S103
B. SAW CUT EDGES AND PREPARE CONCRETE AND REINFORCING STEEL FOR REPAIR. WHERE
REINFORCING STEEL WITH ACTIVE CORROSION IS ENCOUNTERED, SANDBLAST TO A WHITE
METAL FINISH TO REMOVE ALL CONTAMINANTS AND RUST.
C. PRIME REINFORCEMENT WITH 2 COATS OF RUST INHIBITOR. APPLY PER PRODUCT DATA
SHEET AND MANUFACTURERS INSTRUCTION. DO NOT APPLY RUST INHIBITOR. TO THE
CONCRETE SUBSTRATE.
D. APPLY SCUB COAT OF CONCRETE REPAIR MORTAR (FOR HORIZONTAL REPAIR) INTO
PREPARED SURFACE AND WHILE THE SCUB COAT IS STILL WET APPLY THE CONCRETE
REPAIR MORTAR PER MANUFACTURER'S RECOMMENDATIONS.
MATERIAL
A. EPOXY ADHESIVE-LOW PRESSURE INJECTION (SELECT 1 FROM BELOW OR PROVIDE EQUIVALENT)
1. SIKA - SIKADUR 52
2. SIMPSON - CI-LV
3. EMECOLE — METRO 101
B. EPOXY GEL /SURFACE SEALER (SELECT 1 FROM BELOW OR PROVIDE EQUIVALENT)
1. SIKA - SIKADUR 31 HIGH MOD GEL
2. SIMPSON - ETR
3. EMECOLE — METRO 302
C. URETHANE SEALANT- COLOR TO MATCH EXISTING CONCRETE (SELECT 1 FROM BELOW OR PROVIDE
EQUIVALENT)
1. SIKA — MASTERSEAL NP1
2. SHERWIN-WILLIAMS — LOXON TX
3. LYMTAL — ISO-FLEX 825
D. RUST INHIBITOR (SELECT 1 FROM BELOW OR PROVIDE EQUIVALENT)
1. EVONIK — PROTECTOSIL CIT
2. SIKA — ARMATEC 1C
E. CONCRETE REPAIR MORTAR (SELECT 1 FROM BELOW OR PROVIDE EQUIVALENT)
1. SIKA — SIKAREPAIR — 224
2. EUCLID — CONCRETE-TOP SUPREME
3. KAUFMAN — PATCHWELL DEEP
x <= 1/4''
1.
2.
3.
4.
5.
6.
NOTES:
ROUT CRACK TO PROVIDE APPROXIMATELY 1/4" TO 3/8" WIDE V-SHAPED
GROOVE. BACKER ROD IS NEEDED FOR X>1/4" AS PER DETAIL B
CLEAN GROOVE USING OIL-FREE PRESSURIZED AIR.
ALLOW CRACK TO DRY BEFORE APPLYING PRIMER AND SEALANT.
APPLY PRIMER TO CRACK.
APPLY URETHANE SEALANT TO COMPLETELY FILL GROOVE WITH SURFACE OF
SEALANT, FLUSH WITH OR JUST BELOW CONCRETE SURFACE.
TOOL SEALANT TO PROVIDE SMOOTH AND SLIGHTLY CONCAVE SURFACE.
1/4' '< X <= 3/8''
2X
DET B: SEALANT w/
BACKER ROD
DET A: SEALANT
WITHOUT BACKER ROD
RTA DATERTA DATE
DECA LOG #DECA LOG #
A&E FILE NO.A&E FILE NO.
CHECKED BYCHECKED BY
DRAWN BYDRAWN BY
DRAWING DATEDRAWING DATE
DRAWING INFORMATIONDRAWING INFORMATION
DRAWING NO.DRAWING NO.
AS BUILT DATEAS BUILT DATE
DATEDATEDESCRIPTION OF REVISIONSDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWINGREVISION HISTORY OF THIS DRAWING
DATEDATEDESCRIPTION OF REVISIONSDESCRIPTION OF REVISIONS
527-CAL7-SR50-00527-CAL7-SR50-00
COMMONWEALTH OF KENTUCKYCOMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINETFINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICESDEPARTMENT FOR FACILITIES AND SUPPORT SERVICES DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATIONDIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKYFRANKFORT, KENTUCKY
713 Architects, PLLC 9700 Park Plaza Avenue Suite 201 Louisville, KY 40241
500 W Jefferson Street, Suite 2200 Louisville, KY 40202 O: 502.325.0100 www.kpff.com
AS BUILT DATEAS BUILT DATE
S103
EXISTING STONE WALL REPAIR DETAILS
KENTUCKY STATE PENITENTIARY
SECURITY FENCE ADDITION
11/07/2025
JP
YL
2200416
11/07/2025
ACCOUNT NO.
REPOINT JOINT STONE REPAIR
JOINT
CONCRETE SPALL
CRACK IN
CONCRETE CAP
CONCRETE CAP
JOINT
PHOTO 1 PHOTO 2 PHOTO 3 PHOTO 51 2 53
TYPICAL CONCRETE JOINT REPAIR DETAIL6
VOID
PHOTO 44
ADDENDUM 1 01/05/2026
1 1
CRACKING SEALING DETAIL7
| Addendum One |
| 527CAL7_ADD 1_2026-01-05 |
File details come from the government source that posted it. Updated .