Addendum No 1.pdf
PDF 3 MB Posted
- Solicitation number
- RFB-785-2500000649-2
- Issued by
- Jessamine County, Kentucky
About this file
This is Addendum No. 1 for Invitation to Bid No. RFB-237-25, issued by the Commonwealth of Kentucky's Department for Facilities and Support Services, Division of Engineering and Contract Administration for KSP - Post 11 Building Renovations located in Laurel County, Kentucky. The addendum, dated May 6, 2025, provides clarifications and changes to the original bid specifications, including responses to bidder questions about wood blocking attachment, concrete reinforcement details, and exterior masonry repair extent. The document indicates the building is open for additional site visits by appointment, with contact information provided for Sgt. Josh Wilson.
The addendum includes several architectural modifications, such as allowing "G&S Acoustics" as an acceptable manufacturer for sound-absorptive panels, revising specification references, updating wall section details, and changing paint manufacturer references to Sherwin Williams for certain finishes. Attached to the document are revised architectural sheets (A310, A400, A401, A510) and a site meeting sign-in sheet from April 30, 2025. These changes are intended to provide additional clarity and precise guidance for potential bidders on the Kentucky State Police facility renovation project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Final_RFB_785_2500000649_2_SO_FORM.PDF | ||
| Final_RFB_785_2500000649_1_SO_FORM.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-237-25
FOR: KSP - Post 11 Building Renovations Kentucky State Police Laurel County, Kentucky
DATE: May 6, 2025
ADDENDUM NO. One (1)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to attached for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-237-25 For: KSP - Post 11 Building Renovations Kentucky State Police Laurel County, Kentucky
Kristi Sharp, Statewide Procurement Manager Division of Engineering and Contract Administration
Morris Workshop Architects | 151 N. Eagle Creek Drive | Suite 105 | Lexington, Kentucky | 40509
859.300.3745 | www.morrisworkshop.com
KSP Post 11 Building Renovations DECA Account Number: 520-CBBL-VR06-00 Commonwealth of Kentucky MWA Project Number: 2424 11 State Police Road, London, KY 40741 Addendum #1
KSP Post 11 Building Renovations
Addendum #1 Issued: May 5, 2025
BIDDER QUESTIONS:
1. Pg A310 Detail B: what will wood blocking be attached to?
A. The exterior grade wood blocking is to be attached to the CMU wall structure.
2. Pg. A310 detail A & Pg A401 detail G: we are needing to know which detail is correct for the concrete.
One calls for 4’’ over wwf and the other calls for 6’’ w/ #3 @ 24’’ OC.
A. A/A310 SECTION A provides thickness and reinforcement for the mow strip located at the plan north of the building. Detail G/A401 CONCRETE PAVEMENT / SIDEWALK TURNED DOWN EDGE is for the replacement paving located at the plan east and west of the building. Refer to
A100 FLOOR PLAN.
3. Please provide brick count or percentage of tuck pointing for exterior masonry.
A. Extent of exterior repairs are well documented in the Demolition Elevations (AD200) and Repair Photos (AD300 – AD304).
*Building is open to additional site visits by appointment.
Contact Sgt. Josh Wilson 606-878-6622
ARCHITECTURAL
Substitution Request:
1. Refer to specification 098413 FIXED SOUND-ABSORPTIVE PANELS. Provided the vendor meets all product requirements, “G&S Acoustics” may be listed as an acceptable manufacturer.
Plan Sheet Changes:
2. Refer to DEMOLITION / MASONRY REPAIR NOTES on the AD sheets. Revise note 2 to refer to specification 040100 MAITENANCE OF MASONRY instead of 04 0120.63 and 040120.64.
3. Refer to attached revised sheet A310 WALL SECTIONS. Wall sections A, B, and C have been revised to reflect A/A401 TYPICAL DETAIL AT EXTERIOR BEAM ENCASEMENT.
4. Refer to attached revised sheet A400 INTERIOR ELEVATIONS. In the FINISH LEGEND, replace manufacturer for PT-1 and PT-2 with “SHERWIN WILLIAMS CONFLEX SHERLASTIC”.
5. Refer to attached revised sheet A401 DETAILS for revised detail A/A401 TYPICAL DETAIL AT EXTERIOR BEAM ENCASEMETN to extend new soffit panel and insulation to overlap existing soffit.
http://www.morrisworkshop.com/
Morris Workshop Architects | 151 N. Eagle Creek Drive | Suite 105 | Lexington, Kentucky | 40509
859.300.3745 | www.morrisworkshop.com
KSP Post 11 Building Renovations DECA Account Number: 520-CBBL-VR06-00 Commonwealth of Kentucky MWA Project Number: 2424 11 State Police Road, London, KY 40741 Addendum #1
6. Refer to attached revised sheet A510 STOREFRONT. Sill flashing added to 9/A510 DETAIL @
STOREFRONT SILL.
MEP
Attachments:
1. Site Meeting 4/30/25 Sign-in Sheet
2. A310 – WALL SECTIONS
3. A400 – INTERIOR ELEVATIONS
4. A401 – DETAILS
5. A510 - STOREFRONT
END OF ADDENDUM
http://www.morrisworkshop.com/
BILL NOVAK DECA Bill.Novak@ky.gov SGT. WILSON KSP POST 11 Joshua.Wilson@ky.gov KELLIN VELLENOWETH MORRIS WORKSHOP Kellin@morrisworkshop.com BRANDON SARRETT MORRIS WORKSHOP BSarrett@morrisworkshop.com
Site Meeting
FIRST FLOOR
0' - 0"
PARAPET
14' - 8"
ROOF
12' - 0"
A
B.O. OVERHANG
8' - 8"
AA
EXISTING WALL
ALUMINUM STOREFRONT
4" CONCRETE PAVEMENT 4500 PSI
PREFINISHED METAL
DOWNSPOUT
EXISTING WALL
PAINT EXISTING
SOFFIT PANEL, TYP.
SBS MODIFIED BITUMEN ROOF ASSEMBLY
COPING CAP
4'
8" 1'
4"
2'
0"
A401 A
Sim
A401 B
Sim
B
WEEP 24" O.C.
4" DGA COMPACTED TO 95%
STANDARD PROCTOR DENSITY
EXPANSION JOINT
6"x6" WELDED WIRE MESH ON CHAIRS
CONCRETE SPLASH GUARD NOT
TO BE PINNED TO BUILDING
PAINT ENTIRETY OF WALL
TO MATCH EXISTING
SF 1
1' - 0"
8"
4" 4"
EXISTING 6" BATT INSULATION,
VERIFY SOFFIT AND BEAM
COVERAGE IN FIELD, TYP.
FIRST FLOOR
0' - 0"
PARAPET
14' - 8"
ROOF
12' - 0"
B.O. OVERHANG
8' - 8"
Y
A401 A
4'
8" 1'
4"
5'
4"
A401 B
EXISTING WALL
SBS MODIFIED BITUMEN
ROOF ASSEMBLY
EXISTING WALL
NEW COPING CAP
WEEP 24" O.C.
REINSTALL FACE BRICK
NEW BUILDING SIGNAGE
BY OTHERS.
COORDINATE BLOCKING.
ALUMINUM STOREFRONT
PAINT EXISTING SOFFIT PANEL, TYP.
SF 6
FIRST FLOOR
0' - 0"
PARAPET
14' - 8"
ROOF
12' - 0"
B.O. OVERHANG
8' - 8"
Y
EXISTING WALL
4'
8" 1'
4"
3" 5'
1"
BUILDING SIGNAGE BY
OTHERS
SBS MODIFIED BITUMEN ROOF ASSEMBLY
COPING CAP
A401 A
Sim
A401 B
Sim
BLOCKING
WEEP 24" O.C.
EXISTING WALL
1'
7/
8"
ALUMINUM STOREFRONT
CUSTOM ALUMINUM CLOSURE
PANEL, INTERIOR AND EXTERIOR,
TO COVER ADDITIONAL
BLOCKING REQURIED
SF 4
ACCOUNT NO.
DRAWING NO.
DRAWING
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
520-CBBL-VR06-00
PHASE
RTA DATE
DECA LOG #
DRAWING INFORMATION
DESCRIPTION OF REVISIONS DATE DESCRIPTION OF REVISIONS DATE
REVISION HISTORY OF THIS DRAWING
RTA
AS BUILT DATE
04/03/25
A310
WALL SECTIONS
KSP POST 11 BUILDING RENOVATIONS
04/03/2025
KTV / BM
BS / KTTV
SCALE: 3/4" = 1'-0"A310
A SECTION A
SCALE: 3/4" = 1'-0"A310
C SECTION C
SCALE: 3/4" = 1'-0"A310
B SECTION B
PROVIDE EXPANSION JOINTS
EVERY 50' IN CONCRETE SLAB.
INSTALL TWO #3 REBAR 12" LONG
@ 4" O.C. CENTERED IN SLAB. TYP.
PROVIDE TURN DOWNS AT
CONCRETE SLAB EXPANSION
JOINT LOCATIONS. TYP.
1 1
ADD 1 ADD 1
ADD 1
REVISION 1, ADDENDUM 1 05/05/2025
FWP-1
INTERROGATION
101B
EQ. 8' - 0"
4'
1" 3'
1"
RB-1
FIRST FLOOR
0' - 0"
INTERROGATION
101B
FWP-1
EQ.8' - 0"EQ.
3'
1" 4'
1"
RB-1
FIRST FLOOR
0' - 0"
INTERROGATION
101B
FWP-1
EQ. 8' - 0" EQ.
4'
1" 3'
1"
RB-1
FIRST FLOOR
0' - 0"
INTERROGATION
101B
FWP-1
EQ. 8' - 0" EQ.
4'
1" 3'
1"
RB-1
TAG MANUFACTURERCATEGORY DESCRIPTION REMARKS
WALLS
MTL-1 ALUCOBOND COLOR TO BE SELECTED
BY ARCHITECT
FORMAT
BEAM
ENCASEMENT
CORRUGATED
METAL PANEL
FLOORS
ACP-1 MATCH EXISTING
CEILING
MISCELLANEOUS
BRK-1 - -TO MATCH EXISTING8" BRICK -
- -2'-0" x 2'-0"ACOUSTIC
PANEL/GRID
FINISH LEGEND
PT-1 SW 7073
NETWORK GRAY
FIELD WALLELASTOMERIC PAINT SHERWIN WILLIAMS LOXON
PRIMER
PT-2 FIELD WALLELASTOMERIC PAINT
CMU - -INTERIOR WALLCONCRETE
MASONRY UNIT
SHERWIN WILLIAMS
CONFLEX SHERLASTIC
SW 6993
BLACK OF THE NIGHT
SHERWIN WILLIAMS LOXON
PRIMER
*REFER TO SPECIFICATIONS FOR ALL FINISHES
FWP-1 ACOUSTICAL PANEL
SYSTEM (APS, INC)
ECOCORE HI-IMPACT2' x 97" x 2"FABRIC WRAPPED
ACOUSTICAL PANEL
CPT-1 CARPET TILE MATCH EXISTING CHARCOAL GRAYMOHAWK MATCH EXISTING
PT-3 SW 7074
SOFTWARE
DOOR AND FRAMEPAINT -
SF
YKK 45TUREFER TO FRAME
TYPES & SCHEDULE
STOREFRONT BLACK -
RB-1 - JOHNSONITE BLACK4" CONTINUOUSRESILIENT BASE -
SHERWIN WILLIAMS
CONFLEX SHERLASTIC
ACCOUNT NO.
DRAWING NO.
DRAWING
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
520-CBBL-VR06-00
PHASE
RTA DATE
DECA LOG #
DRAWING INFORMATION
DESCRIPTION OF REVISIONS DATE DESCRIPTION OF REVISIONS DATE
REVISION HISTORY OF THIS DRAWING
RTA
AS BUILT DATE
04/03/25
A400
INTERIOR ELEVATIONS
KSP POST 11 BUILDING RENOVATIONS
04/03/2025
KTV / BM
BS / KTTV
SCALE: 1/2" = 1'-0"A400
1 INTERIOR ELEVATION
SCALE: 1/2" = 1'-0"A400
3 INTERIOR ELEVATION
SCALE: 1/2" = 1'-0"A400
4 INTERIOR ELEVATION
SCALE: 1/2" = 1'-0"A400
2 INTERIOR ELEVATION
ROOM FINISH SCHEDULE
NAME FLOOR FINISH BASE WALL FINISH CEILING COMMENTS
STORAGE - - MATCH
EXISTING
INTERROGATION CPT-1 RB-1 PT ACP-1 ARCHITECT TO SELECT
PAINT COLOR
OFFICE - - MATCH
EXISTING
OFFICE - - MATCH
EXISTING
OFFICE - - MATCH
EXISTING
OFFICE - - MATCH
EXISTING
OFFICE - - MATCH
EXISTING
WORKROOM - - MATCH
EXISTING
OFFICE - - MATCH
EXISTING
EVIDENCE - - MATCH
EXISTING
CONTRABAND - - MATCH
EXISTING
1 ADD 1
JAMB ANCOR
4" FACE BRICK
AIR SPACE
1" RIGID INSULATION
6" CONCRETE BLOCK
GROUT FRAME
3"
BRICK ANCOR
A
FIREPROOF SEALANT AT SEAM
EXISTING WALL ASSEMBLY
8" CONCRETE MASONRY UNIT
ROOF
12' - 0"
B.O. OVERHANG
8' - 8"
Y
9 1/2"
1'
7/
8" PARAPET
14' - 8"
ROOF
12' - 0"
Y
6"4"
COPING
EXISTING WALL
MODIFIED BITUMEN ROOF ASSEMBLY
ROOF FINISH TO WRAP
OVER WALL ASSEMBLY
CANT STRIP
COVER BOARD
V.I.F.
EXTERIOR GRADE
BLOCKING
NEW BUILDING SIGNAGE
BY OTHERS
FIRST FLOOR
0' - 0"
PARAPET
14' - 8"
ROOF
12' - 0"
B.O. OVERHANG
8' - 8"
W
ALUMINUM MOUNTING BRACKETS
AND ANCHORS - SIZE AS REQUIRED
TO SUPPORT LOADS. COORDINATE
OFFSET FROM WALL WITH NEW
BEAM WRAP ASSEMBLY.
ALUMINUM MOUNTING BRACKETS
AND ANCHORS - SIZE AS REQUIRED
TO SUPPORT LOADS.
1' -0
" M
AX
ALUMINUM MOUNTING BRACKETS AND
ANCHORS - SIZE AS REQUIRED TO SUPPORT
LOADS, ANCHOR TO CONCRETE PAD
PROVIDE MIN 1/4"X4"X4"
GALVANIZED PLATE @ EACH
5/8" DIA. THROUGH BOLT
PROVIDE MIN 1/4"X4"X4"
GALVANIZED PLATE @ EACH
5/8" DIA. THROUGH BOLT
6" MIN.
FLUID APPLIED AIR BARRIER
M
AX
1'
0"
1'
9" 1'
9"
2' - 0"
FLAT STEEL BAR SIDE RIAL AND
EXTENSION
STEEL BAR GRATING
COORDINATE LADDER
CONFIGURATION WITH
PARAPET WALL
FIRST FLOOR
0' - 0"
PARAPET
14' - 8"
ROOF
12' - 0"
B.O. OVERHANG
8' - 8"
ALUMINUM PANEL SECURITY DOOR ,
HINGED TO SIDE RAIL WITH HASP FOR
PADLOCK BY LADDER MANUFACTURER.
PROVIDE RUBBER BUMPERS TO PREVENT
DOOR FROM BANGING AGAINST LADDER
2 1/4" SERRATED ALUMINUM RUNGS, ALL
RUNGS ARE TO BE EQUALLY SPACED
RUNGS TO BE A MIN OF 6" FROM WALL
ALUMINUM MOUNTING BRACKETS
AND ANCHORS - SIZE AS REQUIRED
TO SUPPORT LOADS.
3" x 1" x 1/8" FLAT
ALUMINUM BAR SIDE RAIL
ALUMINUM MOUNTING BRACKETS AND
ANCHORS - SIZE AS REQUIRED TO SUPPORT
LOADS, ANCHOR TO CONCRETE PAD
ALUMINUM MOUNTING BRIDGING AND
ANCHORS - SIZE AS REQUIRED TO
SUPPORT LOADS
EQ
. S
PA
C
IN
G
1' M
AX
1' -0
" M
AX
1/2" RADIUS
4500 PSI 6" THICK CONCRETE WITH TURNED DOWN
EDGES. FINISH WITH MADIUM BROOM FINISH.
#4 BAR 16" LONG DOWE @ 12" O.C. PLACE INTO
CONCRETE ON ONE END BETWEEN SLABS.
1/2" EXP. JOINT @ 30' O.C. MAX. FILL TOP WITH 1/2"
ELAST. JT. COMPOUNT. TYP.
SAW CUT JOINT 1/4" DEPTH OF CONCRETE THICKNESS.
TYP.
#3 BARS @ 24" O.C. EACH WAY ON CHAIRS
DGA COMPACTED TO 98% STANDARD PROCTOR DENSITY
SUBGRADE COMPACTED TO 98% STANDARD PROCTOR
DENSITY
6" 6"
ACCOUNT NO.
DRAWING NO.
DRAWING
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
520-CBBL-VR06-00
PHASE
RTA DATE
DECA LOG #
DRAWING INFORMATION
DESCRIPTION OF REVISIONS DATE DESCRIPTION OF REVISIONS DATE
REVISION HISTORY OF THIS DRAWING
RTA
AS BUILT DATE
04/03/25
A401
DETAILS
KSP POST 11 BUILDING RENOVATIONS
04/03/2025
KTV / BM
BS / KTTV
SCALE: 1 1/2" = 1'-0"A401
E CMU/BRICK - TYP. DOOR JAMB
SCALE: 1 1/2" = 1'-0"A401
F WALL INTERSECTION DETAIL
SCALE: 1 1/2" = 1'-0"A401
A TYPICAL DETAIL AT EXTERIOR BEAM ENCASEMENT
SHEATHING
BATT INSULATION, VERIFY
CAVITY DEPTH IN FIELD
Z CHANNEL
RIGID MINERAL WOOL
INSULATION (MIN. R-7.5)
FLUID APPLIED AIR BARRIER
250S137-33 @ 24" O.C., TYP.
NEW STAINLESS STEEL THROUGH WALL
FLASHING AND COUNTER FLASHING,
COATED TO MATCH FIELD COLOR
RECONSTRUCTED BRICK VENEER
SOFFIT PANEL
SCALE: 1 1/2" = 1'-0"A401
B TYPICAL DETAIL AT PARAPET
FLAT ACM. PANEL. SEE FINISH SCHEDULE.
DRIP EDGE
SCALE: 1/2" = 1'-0"A401
C LADDER SECTION
SCALE: 1/2" = 1'-0"A401
D LADDER ELEVATION
Z CHANNEL
RIGID MINERAL WOOL
INSULATION (MIN. R-7.5)
J CHANNEL
SHEATHING
FLUID APPLIED AIR BARRIER
PAINT EXISTING SOFFIT
NEW BUILDING SIGNAGE BY OTHERS
SEALANT
TRANSITION FLASHING WITH DRIP EDGE,
SLOPE TO DRAIN, MIN. 1/4" / 1'-0", COLOR
TO MATCH ACM PANEL
SECURE STUDS TO EXISTING STEEL
BEAM W/ (2) L4X4X12 GUAGE W/(1)
PAF. SECURE ANGLE TO STUDS
W/(2) #8-18 SCREWS
MASONRY MORTAR NET MATERIAL
MASONRY WEEPS, TYP 24" O.C.
REGLET
GROUT SOLID
SCALE: 1" = 1'-0"A401
G CONCRETE PAVEMENT / SIDEWALK TURNED DOWN EDGE 1
ADD 1
VIF
23' - 2 1/2"
VI
F
5'
1"
VI
F
3'
4"
SF 4
BAL BAL BAL BAL
EQ EQ EQ EQ
FIRST FLOOR
0' - 0"
VI
F
5'
4"
VI
F
3'
4"
VIF
10' - 6"
SF 6
BAL BAL
EQ EQ
FIRST FLOOR
0' - 0"
VIF
5' - 6"
VI
F
5'
4"
VI
F
3'
4"
SF 7
BAL
FIRST FLOOR
0' - 0"
VI
F
6'
8"
VI
F
2'
0"
SF 1
BAL BAL BAL BAL BAL BAL BAL BAL BAL BAL BAL BAL BAL BAL BAL BAL BAL BAL
EQ 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" EQ
VIF
89' - 4"
FIRST FLOOR
0' - 0"
VI
F
5'
1"
VI
F
3'
4"
VIF
13' - 5"
SF 3
BALBAL
EQ EQ
FIRST FLOOR
0' - 0"
VI
F
5'
4"
VI
F
3'
4"
VIF
3' - 5"
SF 5
BAL
GLAZING TYPE LEGEND
IGU EXTERIOR INSULATED GLAZING PER IECC 2012
SAFETY GLAZING REQUIRED AS INDICATED IN DIAGRAM ABOVE
ASG INSULATED ARCHITECTURAL SAFETY GLAZING
SAFETY GLAZING REQUIRED AS INDICATED IN DIAGRAM ABOVE
BAL LEVEL 3 BALISTIC RATED WINDOW
FIRST FLOOR
0' - 0"
SF 2
BAL
BAL
VI
F
5'
4"
VI
F
3'
4"
VI
F
8'
8"
D O
O R
7'
0" 1'
8"
2' - 2 3/4"
DOOR
3' - 0"
VIF
5' - 5"
M
AT
C H
E
XI
ST
IN
G
EXISTING WALL
ASSEMBLY
FACE BRICK
ALUMINUM
STOREFRONT
FRAMING SYSTEM
JOINT SEALANT
AND BACKER ROD
4"
EXISTING WALL ASSEMBLY
MASONRY WEEPS, TYP. 24" O.C.
SEALANT AND BACKER ROD
ALUMINUM STOREFRONT
FRAMING SYSTEM
4"
MATCH EXISTING
LADDER STYLE VENEER ANCOR, TYP.
METAL FLASHING, INTEGRATED
DRIP EDGE. TYP.
ALUMINUM STOREFRONT
FRAMING SYSTEM
SEALANT AND
BACKER ROD
4"
EXISTING WALL
ASSEMBLY
MATCH EXISTING
EXISTING WALL ASSEMBLY
MASONRY WEEPS, TYP. 24" O.C.
SEALANT AND BACKER ROD
ALUMINUM STOREFRONT
FRAMING SYSTEM
4"
MATCH EXISTING
LADDER STYLE VENEER ANCOR, TYP.
METAL FLASHING
ACCOUNT NO.
DRAWING NO.
DRAWING
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
520-CBBL-VR06-00
PHASE
RTA DATE
DECA LOG #
DRAWING INFORMATION
DESCRIPTION OF REVISIONS DATE DESCRIPTION OF REVISIONS DATE
REVISION HISTORY OF THIS DRAWING
RTA
AS BUILT DATE
04/03/25
A510
STOREFRONT
KSP POST 11 BUILDING RENOVATIONS
04/03/2025
KTV / BM
BS / KTTV
SCALE: 3" = 1'-0"A510
11 DETAIL @ STOREFRONT JAMB
SCALE: 3" = 1'-0"A510
9 DETAIL @ STOREFRONT SILL
SCALE: 3" = 1'-0"A510
8 DETAIL @ STOREFRONT HEAD
SCALE: 3" = 1'-0"A510
10 DETAIL @ STOREFRONT SILL
1 ADD 1
REVISION 1, ADDENDUM 1 05/05/2025
| Addendum No 1.pdf |
| Item 1: Refer to attached for all additions, deletions, and/or changes to specifications and/or drawings. |
| END OF ADDENDUM |
2424 - KSP Building Renovations - Addendum #1.pdf
File details come from the government source that posted it. Updated .