Addendum #4 Tech - RFP 2627-02 BP#4 Athens HS - Addition.pdf

PDF 8 MB Posted

Attached to
RFP2627-02 BP#4A - Athens High School Addition
Solicitation number
RFP TSD 260000002636 5
Issued by
Michigan

About this file

This is Addendum #4 to an RFP issued by the Troy School District in Michigan for Bid Package 4A related to technology systems and structured cabling for the Athens High School Addition project. The addendum, issued October 2, 2026, provides scope clarifications and drawing revisions for the technology infrastructure work across multiple floors and zones of the building addition. The project includes structured cabling for data, audio-visual systems, access control, and video surveillance throughout Zones J, K, and L on the first, second, and third floors. The revisions reflect changes to public address (PA) system drops, with numerous IP PA device data drops deleted and analog PA horn boxes retained; modifications to digital clock cabling color specifications (yellow Cat 6 for Primex clocks, orange Cat 6 for secondary systems, blue Cat 6 for Apple TV devices); clarification that wireless access point symbols indicate both data drop locations and device mounting points; and repositioning of wall phones in science laboratories away from eyewash stations. The bid package was originally scheduled with bids due September 1, 2026.

The addendum addresses responses to multiple Requests for Information (RFI #26 through RFI #38), clarifying faceplate requirements for all data locations, cabling color coding specifications across multiple disciplines, and confirming that wireless access points, cameras, digital clocks, PA devices, Apple TV devices, sound field amplifiers, wall phones, switches, UPS units, and other active equipment are furnished and installed by the owner or other assigned trades rather than the data cabling contractor. An $80,000 Network Cabling/Security/Audio Visual allowance is designated for out-of-scope data cabling work, with costs to be substantiated using unit prices and labor rates from the contract documents. The addendum confirms that end-to-end Hubbell/Belden structured cabling solutions meeting MISSION CRITICAL 25-year system warranty standards are acceptable, provided they comply with the specification's approved manufacturers list. General technology notes throughout the drawings emphasize contractor responsibilities for complete system functionality, field verification, penetrations and firestopping, coordination with other trades, and resolution of any installation conflicts at no additional cost to the owner.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM 4

ADDENDUM 4 ISSUE DATE: October 2, 2026

PROJECT: Troy School District Athens High School Addition Bid Package 4A

DATE: October 2, 2026

TO: All Known Plan Holders

The purpose of this addendum is to clarify information that has been gathered after the release of the drawings and specifications for the Troy School District Bid Package 4A. The following information is included in the Contract Documents.

Scope Clarifications and Drawing Revisions

See attached issued drawings:

1. T3.1K – 1st Floor Zone K Structured Cabling:

a. Deleted all exterior PA data drops as those horns should be analog. NOTE: The boxes need to remain for the analog horn.

b. Deleted many ceiling PA drops associated with IP PA devices.

c. Added DC drop in Emergency Electrical K125.

2. T3.1L – 1st Floor Zone L Structured Cabling:

a. Deleted all exterior PA data drops as those horns should be analog. NOTE: The boxes need to remain for the analog horn.

b. Deleted many ceiling PA drops associated with IP PA devices.

c. Drop for “document camera” added to life skills.

3. T3.2K – 2nd Floor Zone K Structured Cabling:

a. Deleted many ceiling PA drops associated with IP PA devices.

4. T3.2L – 2nd Floor Zone L Structured Cabling:

a. Deleted many ceiling PA drops associated with IP PA devices.

5. T3.3K – 3rd Floor Zone K Structured Cabling:

a. Deleted many ceiling PA drops associated with IP PA devices.

b. Science Lab K301, K304, K319, K321 added blank boxes and pathways for future use by owner.

Wall phones also moved in these labs.

6. T3.3L – 3rd Floor Zone L Structured Cabling:

a. Deleted many ceiling PA drops associated with IP PA devices.

b. Moved WP's in Science Lab L309, L320 to be away from eyewash stations.

c. Science Lab L303, L309, L311, L315, L320 added blank boxes and pathways for future use by owner. Wall phones also moved in these labs.

ADDENDUM 4

ADDENDUM 4 ISSUE DATE: October 2, 2026 Page 2 of 2

RFI Responses

RFI #26

Q: Please specify which locations require a faceplate to be provided by the AV contractor?

A: Provide a wall plate for every data location shown on drawings regardless of device type shown.

RFI #27

Q: Please clarify the color cabling required as the specification does not match the drawing. The drawing states the DC cabling is yellow but that color is not listed in the specification. The ATV shows orange on the drawing but the specifications states it is blue. Please clarify each discipline.

A: Primex Clocks (which occur mostly in classrooms) are marked with BLACK DC data drop. They are to be cabled with yellow cat 6. There are also ORANGE DC data drops, they are to be cabled with orange cat 6. ATV data drops (apple TV) to be always cabled blue.

RFI #29

Q: Please Clarify why there are duplicate AP symbols on the drawings? Are they ceiling mounted AP units?

A: Typically yes, ceiling mounted APs. One symbol is for the data drop (cat 6A) and the other symbol is for the device itself. The network contractor will furnish and install the APs. AP locations are shown for reference, so that drops can be provided in appropriate locations.

RFI #35

Q: Please identify any video-surveillance or IP-paging cable runs expected to exceed the standard

90-meter permanent-link distance so the appropriate approved extended-distance cabling solution can be included.

A: None are anticipated, but the spec covers the extended-distance cabling in case of a unique circumstance.

RFI #36

Q: Please confirm how the required $80,000 Network Cabling / Security / Audio Visual allowance is to be treated relative to bond cost, insurance, contractor fee / markup, and any Bid Form markup limitations.

A: The allowance will be utilized for out of scope data cabling work. We will be utilizing the unit prices and the labor rates and markup from the contract documents to substantiate any costs related to use of the allowance.

RFI #37

Q: Please confirm that wireless access points, cameras, digital clocks, PA devices, Apple TV devices, sound field amplifiers, wall phones, switches, UPS units, and other active equipment are furnished / installed by the Owner or other assigned trades.

A: Yes confirmed. However, coordination is required between data cabling scope and any other trades.

RFI #38

Q: WaTech intends to provide an end-to-end Hubbell / Belden structured cabling solution for this project. The proposed system is eligible for registration under the Hubbell MISSION CRITICAL 25-year system warranty. Please confirm that an end-to-end Hubbell / Belden solution is acceptable for the project in lieu of any other specified manufacturer combination.

A: Please read list of approved manufacturers in the specification.

END OF ADDENDUM

ZONE K

ZONE L

AP

AP

DC

SFA

ATV

PA

AP

AP

ATV

DC

SFA

ATVSFA

AP

AP

AP

AP

ATV

SFA

AP

AP

ATV

DC

SFA

ATV

PA

SFA

ATV

VS

VS

VS

AP

AP

ATV

WP

DC

ATV

AP

AP

DC

AP

AP

ATV

SFAPA

PA

PA

SFA

AP

AP

ATV

PA

IDF 6

VS

ATVSFA

AP

AP

AP

AP

ATV SFA

VS

VS

ATV

SFA

DC

PA

DC

DC

ATV

DC

ATV

AP

AP

DC

ATV

AP

AP

DC

DC

WP

DC

DC

VI

WP

WP

DC

DC

VS

VS

VS

VS

VS

COPIER

AP

AP

ATV

AP

AP

DC

2 DC

DC

AP

AP2

DC

WP

DC ATV

ATV

AP

AP

DC

ATV SFA

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

VS

VS

VS

VS

VS

ATV

AP

AP

AP

AP

ATV

SFA

WP

VS

VS

VS

SFA

WP

VS

VS

ATV

WP

WP

WP

LOCATION TBD

SFA

AP

AP

ATV

DC

ATV

ATV

LEARNING STUDIO

K105

ACTIVE STUDIO

K110

LEARNING STUDIO

K107

LEARNING STUDIO

K109

LEARNING STUDIO

K124

ACTIVE STUDIO

K117

LEARNING STUDIO

K122

LEARNING STUDIO

K120

S.E. LEARNING STUDIO

L134

STAIR

K106

SENSORY ROOM

L115

OT/PT

L120

SMALL GROUP

K108

SMALL GROUP

K121

LAB PREP

K111

STORAGE

K102

ACADEMIC SUPPORT

K127

TOILET

K116

STORAGE

L112

TEACHER OFFICE

L107

ACADEMIC SUPPORT

L111

VESTIBULE

K101

STAIR

L122

STAIR

K123

ELEVATOR

K114

TEACHER OFFICE

K118

TOILET

L108

TOILET

K104

TOILET

L131

CUSTODIAL

L101

I.T.

L113A

TOILET

K119

EMERGENCY ELECTRICAL

K125

CONFERENCE

L132

OFFICE

L121

OFFICE

L119

OFFICE

L118

OFFICE

L116

LIFE SKILLS

L133

PAES LAB

K128

SECLUSION ROOM

L117

MECHANICAL

K126

TEACHER OFFICE

K103

ACADEMIC SUPPORT

K112

STORAGE

K113

LEARNING COMMONS

K100

MAIN STAIR

K130

ELECTRICAL

L113

DC

FOR DOCUMENT CAMERA

BY AV CONTRACTOR

VS

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

STRUCTURED CABLING LEGEND:

COLOR CODE FOR CABLING & JACKS

BLUE - GENERAL DATA

PURPLE - WIRELESS ACCESS POINT

GREEN - SECURITY

ORANGE - EPIC SYSTEM

YELLOW (SHOWN AS BLACK) - BASIC CLOCK SYSTEM

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT (0"-36" AFF)

LOCATED ON WALL, MID HEIGHT (36"-84" AFF)

LOCATED ON WALL, HIGH HEIGHT (84"+ AFF)

LOCATED AT CEILING

OUTLET / PLATE ABBREVIATIONS

# NUMBER OF DATA DROPS

AP WIRELESS ACCESS POINT LOCATION, INCLUDE 1 DATA DROP

ATV APPLE TV DEVICE LOCATION, INCLUDE 1 DATA DROP

DC DIGITAL CLOCK LOCATION, INCLUDE 1 DATA DROP

PA PUBLIC ADDRES SPEAKER LOCATION, INCLUDE 1 DATA DROP

PS PULL STATION LOCATION, INCLUDE 1 DATA DROP

SFA SOUNDFIELD AMPLIFIER LOCATION, INCLUDE 1 DATA DROP

WP WALL PHONE LOCATION, INCLUDE 1 DATA DROP & WALL PHONE PLATE

VS VIDEO SURVEILLANCE CAMERA LOCATION, INCLUDE 1 DATA DROP

HARDWARE

WIRELESS ACCESS POINT, CEILING | WALL MOUNTED

APAP

Owner:

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

DateIssued For

Bid Package 4A

Athens High School Addition

Project Number: 230018

Troy, Michigan

Project Manager: James Elliott

BIDS 09/01/2026

Drawn By: Bill Dawson, CTS

T3.1K

1st Floor Zone K

Structured Cabling

Athens

High School

N

AB

CD

EF

G

H

JK

L

ADDENDUM 4 10/02/2026

ZONE L SFA

AP

AP

ATV

SFA

AP

AP

ATV

AP

AP

ATV SFA

AP

AP

ATV

SFA

ATVSFA

AP

AP

VS

VS

SFA

AP

AP

ATV

PA

PA

AP

AP

ATV

SFA

IDF 6

AP

AP

ATV

WP

ATVSFA

AP

AP

VS

VS

VS

ATV

ATV

VI

DC

DC

VS

VS

VS

DC

DC

ATV

PA

DC

DC

COPIER

AP

AP

ATV

WP

DC

ATV

AP

AP

DC

ATVSFA

AP

AP

DC

WP

DC

DC

DC

DC

VI

DC

DC

DC

AP

AP2

DC

WP

DC ATV

ATV

AP

AP

AP

AP

DC

ATV SFA

AP

AP

VS

AP

AP

AP

AP

AP

AP

VS

VS

VS

WP

VS

VS

SFA

WP

VS

VS

WP

ATV

ATVSFA

ATV

LEARNING STUDIO

L102

ACTIVE STUDIO

L109

STAIR

L103

LEARNING STUDIO

L104

LEARNING STUDIO

L106

S.E. LEARNING STUDIO

L123

S.E. LEARNING STUDIO

L134

S.E. LEARNING STUDIO

L125

SMALL GROUP

L105

SENSORY ROOM

L115

OT/PT

L120

S.E. LEARNING STUDIO

L126

STORAGE

K102

VESTIBULE

L124

SPECIAL EDUCATION

L114

STORAGE

L112

TEACHER OFFICE

L107

ACADEMIC SUPPORT

L111

VESTIBULE

K101

STAIR

L122

ELEVATOR

K114

TOILET

L108

TOILET

K104

TOILET

L131

TOILET

L130

CUSTODIAL

L101

I.T.

L113A

TOILET

L129

TEACHER OFFICE

L127

TOILET

L128

CONFERENCE

L132

OFFICE

L121

OFFICE

L119

OFFICE

L118

OFFICE

L116

LIFE SKILLS

L133

SECLUSION ROOM

L117

STORAGE

K113

LEARNING COMMONS

L100

MAIN STAIR

K130

ELECTRICAL

L113

STORAGE

L135

LAB PREP

L110

FOR DOCUMENT CAMERA

BY AV CONTRACTOR

FRONT

BACK4 POST RACK

(3) 2" SLEEVES

TO ROOM ABOVE

FOR TECHNOLOGY

(BY OTHERS)

OTHER DEVICES ON W

ALL

12" CABLE TRAY

PLYWOOD BY OTHERS

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

STRUCTURED CABLING LEGEND:

COLOR CODE FOR CABLING & JACKS

BLUE - GENERAL DATA

PURPLE - WIRELESS ACCESS POINT

GREEN - SECURITY

ORANGE - EPIC SYSTEM

YELLOW (SHOWN AS BLACK) - BASIC CLOCK SYSTEM

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT (0"-36" AFF)

LOCATED ON WALL, MID HEIGHT (36"-84" AFF)

LOCATED ON WALL, HIGH HEIGHT (84"+ AFF)

LOCATED AT CEILING

OUTLET / PLATE ABBREVIATIONS

# NUMBER OF DATA DROPS

AP WIRELESS ACCESS POINT LOCATION, INCLUDE 1 DATA DROP

ATV APPLE TV DEVICE LOCATION, INCLUDE 1 DATA DROP

DC DIGITAL CLOCK LOCATION, INCLUDE 1 DATA DROP

PA PUBLIC ADDRES SPEAKER LOCATION, INCLUDE 1 DATA DROP

PS PULL STATION LOCATION, INCLUDE 1 DATA DROP

SFA SOUNDFIELD AMPLIFIER LOCATION, INCLUDE 1 DATA DROP

WP WALL PHONE LOCATION, INCLUDE 1 DATA DROP & WALL PHONE PLATE

VS VIDEO SURVEILLANCE CAMERA LOCATION, INCLUDE 1 DATA DROP

HARDWARE

WIRELESS ACCESS POINT, CEILING | WALL MOUNTED

APAP

Owner:

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

DateIssued For

Bid Package 4A

Athens High School Addition

Project Number: 230018

Troy, Michigan

Project Manager: James Elliott

BIDS 09/01/2026

Drawn By: Bill Dawson, CTS

T3.1L

1st Floor Zone L

Structured Cabling

Athens

High School

N

IDF 6 Enlarged Plan

SCALE: 1/2" = 1'

AB

CD

EF

G

H

JK

VS

AP

AP

ATV

DC

SFA

ATV

PA

AP

AP

ATV

DC

SFA

ATVSFA

AP

AP

AP

AP

ATV

SFA

DC

ATV

PA

VS

AP

AP

ATV

DC

ATV

AP

AP

DC

AP

AP

ATV

SFA

PA

PA

SFA

AP

AP

ATV

PA

IDF 7

VS

ATV

DC

ATV

DC

ATV

AP

AP

DC

PA

DC

DC

DC

COPIER

PA

ATVSFA

AP

AP

DC

AP

AP

ATV

DC

SFA

ATV

PA

ATV

PA

AP

AP

ATV

SFA

SFA

AP

AP

ATV

DC

DC

SFA

AP

AP

ATV

DC

AP

AP

AP

AP

ATV

SFA

DC

AP

AP

ATV

SFA

DC

AP

AP

ATV

DC

DC

AP

AP

ATV1

WP

PA

AP

AP

AP

AP

AP

AP

AP

AP

VS

VS

VS

DC

WP

VS

DC

VS

SFA

ATV

WP

WP

WP

ZONE K

ZONE L

LEARNING STUDIO

L220

LEARNING STUDIO

K208

LEARNING STUDIO

K202

LEARNING STUDIO

K219

LEARNING STUDIO

K221

STAIR

K207

STAIR

K220

STORAGE

L214

ELEVATOR

K223

STORAGE

K203

TEACHER OFFICE

K204

LEARNING STUDIO

K210

LEARNING STUDIO

K217

SMALL GROUP

K209

SMALL GROUP

K218

ACADEMIC SUPPORT

K222

ACADEMIC SUPPORT

L215

TEACHER OFFICE

TOILET

L205

CUSTODIAL

L202

I.T.

L201A

TOILET

K205

ACADEMIC SUPPORT

K214

TOILET

L218

LEARNING STUDIO

L203

LEARNING STUDIO

K215

SMALL GROUP

K211

SMALL GROUP

K216

LEARNING STUDIO

K212

LEARNING STUDIO

L216

COUNSELING CLASSROOM

K223

MAIN STAIR

K230

ELECTRICAL

L201

TOILET

K213

LEARNING STUDIO

K206

LEARNING COMMONS

K224

TOILET

L213

VS

VS

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

STRUCTURED CABLING LEGEND:

COLOR CODE FOR CABLING & JACKS

BLUE - GENERAL DATA

PURPLE - WIRELESS ACCESS POINT

GREEN - SECURITY

ORANGE - EPIC SYSTEM

YELLOW (SHOWN AS BLACK) - BASIC CLOCK SYSTEM

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT (0"-36" AFF)

LOCATED ON WALL, MID HEIGHT (36"-84" AFF)

LOCATED ON WALL, HIGH HEIGHT (84"+ AFF)

LOCATED AT CEILING

OUTLET / PLATE ABBREVIATIONS

# NUMBER OF DATA DROPS

AP WIRELESS ACCESS POINT LOCATION, INCLUDE 1 DATA DROP

ATV APPLE TV DEVICE LOCATION, INCLUDE 1 DATA DROP

DC DIGITAL CLOCK LOCATION, INCLUDE 1 DATA DROP

PA PUBLIC ADDRES SPEAKER LOCATION, INCLUDE 1 DATA DROP

PS PULL STATION LOCATION, INCLUDE 1 DATA DROP

SFA SOUNDFIELD AMPLIFIER LOCATION, INCLUDE 1 DATA DROP

WP WALL PHONE LOCATION, INCLUDE 1 DATA DROP & WALL PHONE PLATE

VS VIDEO SURVEILLANCE CAMERA LOCATION, INCLUDE 1 DATA DROP

HARDWARE

WIRELESS ACCESS POINT, CEILING | WALL MOUNTED

APAP

Owner:

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

DateIssued For

Bid Package 4A

Athens High School Addition

Project Number: 230018

Troy, Michigan

Project Manager: James Elliott

BIDS 09/01/2026

Drawn By: Bill Dawson, CTS

T3.2K

2nd Floor Zone K

Structured Cabling

Athens

High School

N

AB

CD

EF

G

H

JK

FRONT

4 POST RACK

(3) 2" SLEEVES

BETWEEN ROOMS

BELOW & ABOVE

FOR TECHNOLOGY

(BY OTHERS)

OTHER DEVICES ON W

ALL

12" CABLE TRAY

PLYWOOD BY OTHERS

BACK

VS

SFA

AP

AP

ATV

SFA

AP

AP

ATV

AP

AP

ATV SFA

ATVSFA

AP

AP

VS

SFA

AP

AP

ATV

PA

PA

AP

AP

ATV

SFA

IDF 7

ATV

ATV

DC

DC

DC

ATV

PA

DC

DC

COPIER

PA

ATVSFA

AP

AP

DC

DC

DC

SFA

AP

AP

ATV

DC

AP

AP

SFA

DC

ATV

PA

ATV

PA

ATV

PA

DC

AP

AP

ATV SFA

AP

AP

ATV

SFA

DC

AP

AP

ATV

SFA

DC

AP

AP

ATV

DC

DC

AP

AP

ATV1

WP

PA

DC

SFA

AP

AP

ATV

AP

AP

AP

AP

AP

AP

VS

VS

VS

DC

WP

AP

AP

ATV

VS

DC

ATV

WP

ZONE K

ZONE L

LEARNING STUDIO

L208

LEARNING STUDIO

L206 LEARNING STUDIO

L222

LEARNING STUDIO

L220

LEARNING STUDIO

K202

STAIR

L207

STAIR

L221

STORAGE

L214

TEACHER OFFICE

L204

ELEVATOR

K223

STORAGE

K203

LEARNING STUDIO

L210

LEARNING STUDIO

L224

SMALL GROUP

L209

SMALL GROUP

L223

SMALL GROUP

L211

SMALL GROUP

L225

LEARNING STUDIO

L212

ACADEMIC SUPPORT

L215

TEACHER OFFICE

L217

TOILET

L205

CUSTODIAL

L202

I.T.

L201A

K205

TOILET

L218

LEARNING STUDIO

L203

LEARNING STUDIO

L216

MAIN STAIR

K230

ELECTRICAL

L201

LEARNING COMMONS

L200

TOILET

L213

LEARNING STUDIO

L226

VS

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

STRUCTURED CABLING LEGEND:

COLOR CODE FOR CABLING & JACKS

BLUE - GENERAL DATA

PURPLE - WIRELESS ACCESS POINT

GREEN - SECURITY

ORANGE - EPIC SYSTEM

YELLOW (SHOWN AS BLACK) - BASIC CLOCK SYSTEM

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT (0"-36" AFF)

LOCATED ON WALL, MID HEIGHT (36"-84" AFF)

LOCATED ON WALL, HIGH HEIGHT (84"+ AFF)

LOCATED AT CEILING

OUTLET / PLATE ABBREVIATIONS

# NUMBER OF DATA DROPS

AP WIRELESS ACCESS POINT LOCATION, INCLUDE 1 DATA DROP

ATV APPLE TV DEVICE LOCATION, INCLUDE 1 DATA DROP

DC DIGITAL CLOCK LOCATION, INCLUDE 1 DATA DROP

PA PUBLIC ADDRES SPEAKER LOCATION, INCLUDE 1 DATA DROP

PS PULL STATION LOCATION, INCLUDE 1 DATA DROP

SFA SOUNDFIELD AMPLIFIER LOCATION, INCLUDE 1 DATA DROP

WP WALL PHONE LOCATION, INCLUDE 1 DATA DROP & WALL PHONE PLATE

VS VIDEO SURVEILLANCE CAMERA LOCATION, INCLUDE 1 DATA DROP

HARDWARE

WIRELESS ACCESS POINT, CEILING | WALL MOUNTED

APAP

Owner:

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

DateIssued For

Bid Package 4A

Athens High School Addition

Project Number: 230018

Troy, Michigan

Project Manager: James Elliott

BIDS 09/01/2026

Drawn By: Bill Dawson, CTS

T3.2L

2nd Floor Zone L

Structured Cabling

Athens

High School

N

IDF 7 Enlarged Plan

SCALE: 1/2" = 1'

AB

CD

EF

G

H

JK

ZONE K

ZONE L

AP

AP

ATV

DC

SFA

ATV

PA

AP

AP

ATV

SFA

DC

WP

ATV

PA

VS

SFA

ATV

VS

VS

AP

AP

ATV

DC

AP

AP

ATV

SFA

PA

PA

PA

SFA

AP

AP

ATV

WP

PA

IDF 8

ATV

AP

AP

DC

PA

DC

DC

DC

DC

COPIER

COPIER

PA

AP

AP

ATV

SFA

AP

AP

ATV

SFA

DC

SFA

AP

AP

ATV

DC

AP

AP

ATV

PA

DC

SFA

AP

AP

ATV

AP

AP

AP

AP

AP

AP

AP

AP

VS

PA

ATV

PA

ATV

PA

VS

WP

WP

PA

ATV

VS

DC

SFA

AP

AP

ATV

DC

AP

AP

ATV

SFA

WP

WP

WP

DC

AP

AP

ATV

DC

DC

ELEVATOR

VS

VS

VS

DC

VS

WP

ATV

LEARNING STUDIO

K308

SMALL GROUP

K309

SMALL GROUP

K316

STAIR

K307

STAIR

L317

STAIR

K318

SCIENCE LAB

K301

LEARNING COMMONS

K300

ELEVATOR

K302

STORAGE

L313

TEACHER OFFICE

L304

STORAGE

K303

TEACHER OFFICE

K305

TOILET

K313

ACADEMIC SUPPORT

L316

TOILET

L305

CUSTODIAL

L302

I.T.

L301A

TOILET

K306

ACADEMIC SUPPORT

K312

TOILET

L312

SCIENCE LAB

K319

SCIENCE LAB

K321

SCIENCE LAB

L315

SCIENCE LAB

K304

SCIENCE LAB

L303

COMPUTER LAB

K317

LEARNING STUDIO

K320

STORAGE

L314

SMALL GROUP

K311

SMALL GROUP

K314

LAB PREP

K315

OUTDOOR PATIO

K310

MAIN STAIR

K330

ELECTRICAL

L301

ELEVATOR MECHANICAL

K302A

SFA

ATV

AP

AP

DC

WP

VS

VS

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

STRUCTURED CABLING LEGEND:

COLOR CODE FOR CABLING & JACKS

BLUE - GENERAL DATA

PURPLE - WIRELESS ACCESS POINT

GREEN - SECURITY

ORANGE - EPIC SYSTEM

YELLOW (SHOWN AS BLACK) - BASIC CLOCK SYSTEM

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT (0"-36" AFF)

LOCATED ON WALL, MID HEIGHT (36"-84" AFF)

LOCATED ON WALL, HIGH HEIGHT (84"+ AFF)

LOCATED AT CEILING

OUTLET / PLATE ABBREVIATIONS

# NUMBER OF DATA DROPS

AP WIRELESS ACCESS POINT LOCATION, INCLUDE 1 DATA DROP

ATV APPLE TV DEVICE LOCATION, INCLUDE 1 DATA DROP

DC DIGITAL CLOCK LOCATION, INCLUDE 1 DATA DROP

PA PUBLIC ADDRES SPEAKER LOCATION, INCLUDE 1 DATA DROP

PS PULL STATION LOCATION, INCLUDE 1 DATA DROP

SFA SOUNDFIELD AMPLIFIER LOCATION, INCLUDE 1 DATA DROP

WP WALL PHONE LOCATION, INCLUDE 1 DATA DROP & WALL PHONE PLATE

VS VIDEO SURVEILLANCE CAMERA LOCATION, INCLUDE 1 DATA DROP

HARDWARE

WIRELESS ACCESS POINT, CEILING | WALL MOUNTED

APAP

Owner:

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

DateIssued For

Bid Package 4A

Athens High School Addition

Project Number: 230018

Troy, Michigan

Project Manager: James Elliott

BIDS 09/01/2026

Drawn By: Bill Dawson, CTS

T3.3K

3rd Floor Zone K

Structured Cabling

Athens

High School

N

AB

CD

EF

G

H

JK

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

STRUCTURED CABLING LEGEND:

COLOR CODE FOR CABLING & JACKS

BLUE - GENERAL DATA

PURPLE - WIRELESS ACCESS POINT

GREEN - SECURITY

ORANGE - EPIC SYSTEM

YELLOW (SHOWN AS BLACK) - BASIC CLOCK SYSTEM

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT (0"-36" AFF)

LOCATED ON WALL, MID HEIGHT (36"-84" AFF)

LOCATED ON WALL, HIGH HEIGHT (84"+ AFF)

LOCATED AT CEILING

OUTLET / PLATE ABBREVIATIONS

# NUMBER OF DATA DROPS

AP WIRELESS ACCESS POINT LOCATION, INCLUDE 1 DATA DROP

ATV APPLE TV DEVICE LOCATION, INCLUDE 1 DATA DROP

DC DIGITAL CLOCK LOCATION, INCLUDE 1 DATA DROP

PA PUBLIC ADDRES SPEAKER LOCATION, INCLUDE 1 DATA DROP

PS PULL STATION LOCATION, INCLUDE 1 DATA DROP

SFA SOUNDFIELD AMPLIFIER LOCATION, INCLUDE 1 DATA DROP

WP WALL PHONE LOCATION, INCLUDE 1 DATA DROP & WALL PHONE PLATE

VS VIDEO SURVEILLANCE CAMERA LOCATION, INCLUDE 1 DATA DROP

HARDWARE

WIRELESS ACCESS POINT, CEILING | WALL MOUNTED

APAP

FRONT

4 POST RACK

2 POST RACK WITH CABLE

MANAGEMENT BOTH SIDES

(3) 2" SLEEVES

TO ROOM BELOW

FOR TECHNOLOGY

(BY OTHERS)

OTHER DEVICES ON W

ALL

12" CABLE TRAY

PLYWOOD BY OTHERS

BACK

ZONE K

ZONE L

ZONE K

ZONE L

SFA

AP

AP

ATV

SFA

AP

AP

ATV

AP

AP

ATV SFA

ATVSFA

WP

AP

AP

VS

SFA

AP

AP

ATV

PA

PA

WP

AP

AP

ATV

SFA

IDF 8

ATV

DC

DC

DC

DC

ATV

PA

DC

DC

COPIER

PA

DC

DC

AP

AP

ATV

SFA

DC

ATV

PA

DC

AP

AP

ATV

PA

DC

SFA

AP

AP

ATV

AP

AP

AP

AP

AP

VS

VS

WP

VS

DC

AP

AP

ATV

SFA

WP

AP

AP ATV SFA

DC

PA

WP

WP

WP

DC

WP

AP

AP

ATV

ELEVATOR

VS

VS

VS

ON ROOF FOR

PARAPET CAMERA

DC

WP

LEARNING STUDIO

L307

SMALL GROUP

L308

SMALL GROUP

L319

STAIR

L306

STAIR

L317

SCIENCE LAB

L320

SCIENCE LAB

K301

STORAGE

L313

TEACHER OFFICE

L304

STORAGE

K303

ACADEMIC SUPPORT

L316

TOILET

L305

CUSTODIAL

L302

I.T.

L301A

TOILET

L312

SCIENCE LAB

L315

SCIENCE LAB

L303

LEARNING STUDIO

L318

STORAGE

L314

LAB PREP

L310

SCIENCE LAB

L311

SCIENCE LAB

L309

LEARNING COMMONS

L300

MAIN STAIR

K330

ELECTRICAL

L301

ELEVATOR MECHANICAL

K302A

VS

Owner:

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

DateIssued For

Bid Package 4A

Athens High School Addition

Project Number: 230018

Troy, Michigan

Project Manager: James Elliott

BIDS 09/01/2026

Drawn By: Bill Dawson, CTS

T3.3L

3rd Floor Zone L

Structured Cabling

Athens

High School

N

IDF 8 Enlarged Plan

SCALE: 1/2" = 1'

AB

CD

EF

G

H

JK

ZONE F

ZONE J

ZO

NE J

ZO

NE D

D2

FPATV

CONFERENCE SOLUTION

CABLE TO CONFERENCE BAR

THROUGH FLOOR BOX

3C

D1

D1

PA

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

AUDIOVISUAL & EPIC SYSTEMS LEGEND:

COLOR CODE

GREEN - AUDIOVISUAL SYSTEM DEVICE

PURPLE - IP EPIC DEVICE

BROWN - ANALOG EPIC DEVICE

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT

LOCATED ON WALL, MID HEIGHT

LOCATED ON WALL, HIGH HEIGHT

OUTLET / PLATE ABBREVIATIONS

A AUDIO PLATE: SEE SCHEMATIC

V AUDIO AND / OR VIDEO PLATE: SEE SCHEMATIC

AV LEGACY AUDIOVISUAL INTERFACE

HARDWARE

FLAT PANEL DISPLAY, CEILING OR CART MOUNTED | WALL MOUNTED, MINIMUM SIZE INDICATED

PROJECTOR, CEILING MOUNTED

APPLE TV (OWNER FURNISHED, CONTRACTOR INSTALLED), TYPICALLY CEILING MOUNTED

DISPLAY ELEVATION - SEE SHEET T9.4

SOUNDFIELD AMPLIFIER | XD RECEIVER, WALL MOUNTED

AUDIO ENHANCEMENTS: MS-700 KIT UNLESS OTHERWISE NOTED

ZONE CONTROLLER & AMPLIFIER, RACK LOCATED, AUDIO ENHANCEMENTS: CZA-1300

DOOR SENSOR INTERFACE(S), BARIX: BARIONET 50

PJ

FP

XD

DSI

ATV

SFA

ZC

FP

D1

D2

IP DIGITAL ANNOUNCER, SINGLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPSWDHD-MW

IP DIGITAL ANNOUNCER, DOUBLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPCSHD-DS-MB

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, PRIMEX: 125-PE115G

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, LARGE SIZE

IP STROBE, WALL MOUNTED, ALGO, MULTI-COLOR: 8138

IP PA SPEAKER, CEILING MOUNTED, ADVANCED NETWORK DEVICES: IPSCM-RMe

INCLUDE BACKBOX FOR WALL MOUNT AND HARD / EXPOSED CEILING APPLICATIONS

ANALOG PA SPEAKER, CEILING MOUNTED, WITH 70V TRANSFORMER & POTENTIOMETER VOLUME CONTROL

INCLUDE BACKBOX FOR WALL MOUNT AND HARD / EXPOSED CEILING APPLICATIONS

TOUCH CONTROLLER, AUDIO ENHANCEMENT: INTERACTIVE TOUCH CONTROLLER

SOUNDFIELD SPEAKER, CEILING | WALL MOUNTED

PAGING HORN, WALL MOUNTED, AUDIO ENHANCEMENTS: SP-1091, TAP 15 WATTS

CALL BUTTON, WALL MOUNTED

SF

HN

PA

SF

ITC

CB

D3

D4

S

PA

CALL BUTTON BOX, NO CABLE / HARDWARE, WALL MOUNTED - INCLUDE STAINLESS BLANK COVER PLATE

AUDIOVISUAL SYSTEMS NEW PROJECT NOTES:

1. WHERE SHOWN, CABLE DEVICES TO LOCATIONS IDENTIFIED; DAISY-CHAIN 70V SPEAKERS/HORNS WITH

COMMON HEAD END.

Owner:

Project Number: 230018

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

Project Manager: James Elliott

Drawn By: Bill Dawson, CTS

DateIssued For

Bid Package T5

Technology Systems

Troy, Michigan

REFERENCE ONLY 09/17/2026

NOT FOR CONSTRUCTION

T5.1J

1st Floor Zone J

Audiovisual Systems

EPIC System

Athens

High School

N

AB

CD

EF

G

H

JK

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

AUDIOVISUAL & EPIC SYSTEMS LEGEND:

COLOR CODE

GREEN - AUDIOVISUAL SYSTEM DEVICE

PURPLE - IP EPIC DEVICE

BROWN - ANALOG EPIC DEVICE

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT

LOCATED ON WALL, MID HEIGHT

LOCATED ON WALL, HIGH HEIGHT

OUTLET / PLATE ABBREVIATIONS

A AUDIO PLATE: SEE SCHEMATIC

V AUDIO AND / OR VIDEO PLATE: SEE SCHEMATIC

AV LEGACY AUDIOVISUAL INTERFACE

HARDWARE

FLAT PANEL DISPLAY, CEILING OR CART MOUNTED | WALL MOUNTED, MINIMUM SIZE INDICATED

PROJECTOR, CEILING MOUNTED

APPLE TV (OWNER FURNISHED, CONTRACTOR INSTALLED), TYPICALLY CEILING MOUNTED

DISPLAY ELEVATION - SEE SHEET T9.4

SOUNDFIELD AMPLIFIER | XD RECEIVER, WALL MOUNTED

AUDIO ENHANCEMENTS: MS-700 KIT UNLESS OTHERWISE NOTED

ZONE CONTROLLER & AMPLIFIER, RACK LOCATED, AUDIO ENHANCEMENTS: CZA-1300

DOOR SENSOR INTERFACE(S), BARIX: BARIONET 50

PJ

FP

XD

DSI

ATV

SFA

ZC

FP

ZONE K

ZONE L

FPSFA

FP

D3

SF

SF

SF

SF

ATV

PA

XD

1A

ATV

FP

SFA

SF

SF

SF

SF

XD

ATV

FP

SFA

SF

SF

SF

SF

XD

ATV

FPSFA

SF

SF

SF

SF

XD

ATV

FPSFA

D3

SF

SF

SF

SF

XD

ATV

FP

ATV

PA

1A

FP SFA

ATV

FP

ATV

FP

D1

FPATV

D1

FPSFA

SF

SF

SF

SF

XD

ATV

PA

PA

PA

FP SFA

XD

SF

SF

ATV

SF

SF

PA

IDF 6

FP

SFA XD

ATV

SF

SF

SF

SF

FP

SFA

SF

SF

SF

SF

XD

ATV

DSI

HN

HN

HN

HN

HN

HN

FP ATV

ITC

ITC

D3

FP

SFA XD

ITC

D3

PA

ITC

D3

ITC

D3

ITC

FP ATV

D1 -

ATV

D1

PA

PA

FP

ATV

D1 -

PA

D3 ITC

D3ITC

D2

D2

PA

FP

ATV

D1 -

PA

D3ITC

D1-

FP

ATV V

D1

TEAMS CONFERENCE SOLUTION

CABLE TO CONFERENCE BAR

THROUGH FLOOR BOX

SF

SF

SF

SF

ITC

D3

FP ATV

ITC

D3

FP

SFAXD

ATV

SF

SF

SF

SF

ATV

FPSFA

SF

SF

SF

SF

XD

ATV

SFA

SF

SF

XD

SF

SF

4A

4A 4A

4A 4A

4A

4A

3C

3A

3A

3C

3C

4A

4A

4A

3C

3B

3C

4A

4A

4A

3A

D1

FP SFA

XD

SF

SF

ATV

SF

SF

D3ITC

4A

FP

ATV

3C

SF

FP

ATV3C

PA

PA

PA

D1

PA

PA

ZC

EXTERIOR ZONE

PA

PA

PA

PA

PA

PA

PA

PA

FROM ZC IN IDF 7

D1

D2

IP DIGITAL ANNOUNCER, SINGLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPSWDHD-MW

IP DIGITAL ANNOUNCER, DOUBLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPCSHD-DS-MB

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, PRIMEX: 125-PE115G

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, LARGE SIZE

IP STROBE, WALL MOUNTED, ALGO, MULTI-COLOR: 8138

IP PA SPEAKER, CEILING MOUNTED, ADVANCED NETWORK DEVICES: IPSCM-RMe

INCLUDE BACKBOX FOR WALL MOUNT AND HARD / EXPOSED CEILING APPLICATIONS

ANALOG PA SPEAKER, CEILING MOUNTED, WITH 70V TRANSFORMER & POTENTIOMETER VOLUME CONTROL

INCLUDE BACKBOX FOR WALL MOUNT AND HARD / EXPOSED CEILING APPLICATIONS

TOUCH CONTROLLER, AUDIO ENHANCEMENT: INTERACTIVE TOUCH CONTROLLER

SOUNDFIELD SPEAKER, CEILING | WALL MOUNTED

PAGING HORN, WALL MOUNTED, AUDIO ENHANCEMENTS: SP-1091, TAP 15 WATTS

CALL BUTTON, WALL MOUNTED

SF

HN

PA

SF

ITC

CB

D3

D4

S

PA

CALL BUTTON BOX, NO CABLE / HARDWARE, WALL MOUNTED - INCLUDE STAINLESS BLANK COVER PLATE

AUDIOVISUAL SYSTEMS NEW PROJECT NOTES:

1. WHERE SHOWN, CABLE DEVICES TO LOCATIONS IDENTIFIED; DAISY-CHAIN 70V SPEAKERS/HORNS WITH

COMMON HEAD END.

Owner:

Project Number: 230018

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

Project Manager: James Elliott

Drawn By: Bill Dawson, CTS

DateIssued For

Bid Package T5

Technology Systems

Troy, Michigan

REFERENCE ONLY 09/17/2026

NOT FOR CONSTRUCTION

T5.1K

1st Floor Zone K

Audiovisual Systems

EPIC System

Athens

High School

N

AB

CD

EF

G

H

FP SFA

XD

SF

SF

ATV

SF

SF

FP SFA

XD

SF

SF

ATV

SF

SF

FP

SFA

SF

SF

SF

SF

XD

ATV

FP

SFA

SF

SF

SF

SF

XD

ATV

FP

SFA

SF

SF

SF

SF

XD

ATV

FP SFA

XD SF

SF

SF

SF

ATV

PA

PA

SF

SF

FPSFA

SF

SF

SF

SF

XD

ATV

IDF 6

FP

ATV

SF

SF

SF

SF

PA

FP

SFA XD

ATV

DSI

HN

HN

HN

HN

HN

FP ATV

FP ATV

PA

D2

D2

D3 ITC

D3 ITC

FP

ATV

PA

1A

D3

ITC

D1

PA

FP

ATV D1

FP

ATV

D1 -

PA

FP

SFA XD

ATV

D3

ITC

D1

D3

ITC

D3

ITC

D1

D3ITC

D3ITC

D1-

FP

ATV V

D1

TEAMS CONFERENCE SOLUTION

CABLE TO CONFERENCE BAR

THROUGH FLOOR BOX

SF

SF

SF

SF

ITC

D3

FP ATV

ITC

D3

FP

SFAXD

ATV

SF

SF

SF

SF

SFA

SF

SF

XD

SF

SF

3C

3C

3B

3C

4A

4A

4A

4A

4A

3C

4A 4A

4A

4A

3C

3A

4A

FP

ATV

3C

FP

SFA XD

ATV

SF

SF

SF

SF

4A

FP

ATV3C

PA

PA

PA

PA

CONNECT ONE TO EACH

CHANNEL OF L109 SFA

PA

ZC

EXTERIOR ZONE

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

FROM ZC IN IDF 7

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

AUDIOVISUAL & EPIC SYSTEMS LEGEND:

COLOR CODE

GREEN - AUDIOVISUAL SYSTEM DEVICE

PURPLE - IP EPIC DEVICE

BROWN - ANALOG EPIC DEVICE

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT

LOCATED ON WALL, MID HEIGHT

LOCATED ON WALL, HIGH HEIGHT

OUTLET / PLATE ABBREVIATIONS

A AUDIO PLATE: SEE SCHEMATIC

V AUDIO AND / OR VIDEO PLATE: SEE SCHEMATIC

AV LEGACY AUDIOVISUAL INTERFACE

HARDWARE

FLAT PANEL DISPLAY, CEILING OR CART MOUNTED | WALL MOUNTED, MINIMUM SIZE INDICATED

PROJECTOR, CEILING MOUNTED

APPLE TV (OWNER FURNISHED, CONTRACTOR INSTALLED), TYPICALLY CEILING MOUNTED

DISPLAY ELEVATION - SEE SHEET T9.4

SOUNDFIELD AMPLIFIER | XD RECEIVER, WALL MOUNTED

AUDIO ENHANCEMENTS: MS-700 KIT UNLESS OTHERWISE NOTED

ZONE CONTROLLER & AMPLIFIER, RACK LOCATED, AUDIO ENHANCEMENTS: CZA-1300

DOOR SENSOR INTERFACE(S), BARIX: BARIONET 50

PJ

FP

XD

DSI

ATV

SFA

ZC

FP

D1

D2

IP DIGITAL ANNOUNCER, SINGLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPSWDHD-MW

IP DIGITAL ANNOUNCER, DOUBLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPCSHD-DS-MB

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, PRIMEX: 125-PE115G

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, LARGE SIZE

IP STROBE, WALL MOUNTED, ALGO, MULTI-COLOR: 8138

IP PA SPEAKER, CEILING MOUNTED, ADVANCED NETWORK DEVICES: IPSCM-RMe

INCLUDE BACKBOX FOR WALL MOUNT AND HARD / EXPOSED CEILING APPLICATIONS

ANALOG PA SPEAKER, CEILING MOUNTED, WITH 70V TRANSFORMER & POTENTIOMETER VOLUME CONTROL

INCLUDE BACKBOX FOR WALL MOUNT AND HARD / EXPOSED CEILING APPLICATIONS

TOUCH CONTROLLER, AUDIO ENHANCEMENT: INTERACTIVE TOUCH CONTROLLER

SOUNDFIELD SPEAKER, CEILING | WALL MOUNTED

PAGING HORN, WALL MOUNTED, AUDIO ENHANCEMENTS: SP-1091, TAP 15 WATTS

CALL BUTTON, WALL MOUNTED

SF

HN

PA

SF

ITC

CB

D3

D4

S

PA

CALL BUTTON BOX, NO CABLE / HARDWARE, WALL MOUNTED - INCLUDE STAINLESS BLANK COVER PLATE

AUDIOVISUAL SYSTEMS NEW PROJECT NOTES:

1. WHERE SHOWN, CABLE DEVICES TO LOCATIONS IDENTIFIED; DAISY-CHAIN 70V SPEAKERS/HORNS WITH

COMMON HEAD END.

Owner:

Project Number: 230018

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

Project Manager: James Elliott

Drawn By: Bill Dawson, CTS

DateIssued For

Bid Package T5

Technology Systems

Troy, Michigan

REFERENCE ONLY 09/17/2026

NOT FOR CONSTRUCTION

T5.1L

1st Floor Zone L

Audiovisual Systems

EPIC System

Athens

High School

N

AB

CD

EF

G

H

D2DC

VS

AP

SF

VS

AP

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

AUDIOVISUAL & EPIC SYSTEMS LEGEND:

COLOR CODE

GREEN - AUDIOVISUAL SYSTEM DEVICE

PURPLE - IP EPIC DEVICE

BROWN - ANALOG EPIC DEVICE

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT

LOCATED ON WALL, MID HEIGHT

LOCATED ON WALL, HIGH HEIGHT

OUTLET / PLATE ABBREVIATIONS

A AUDIO PLATE: SEE SCHEMATIC

V AUDIO AND / OR VIDEO PLATE: SEE SCHEMATIC

AV LEGACY AUDIOVISUAL INTERFACE

HARDWARE

FLAT PANEL DISPLAY, CEILING OR CART MOUNTED | WALL MOUNTED, MINIMUM SIZE INDICATED

PROJECTOR, CEILING MOUNTED

APPLE TV (OWNER FURNISHED, CONTRACTOR INSTALLED), TYPICALLY CEILING MOUNTED

DISPLAY ELEVATION - SEE SHEET T9.4

SOUNDFIELD AMPLIFIER | XD RECEIVER, WALL MOUNTED

AUDIO ENHANCEMENTS: MS-700 KIT UNLESS OTHERWISE NOTED

ZONE CONTROLLER & AMPLIFIER, RACK LOCATED, AUDIO ENHANCEMENTS: CZA-1300

DOOR SENSOR INTERFACE(S), BARIX: BARIONET 50

PJ

FP

XD

DSI

ATV

SFA

ZC

FP

D1

D2

IP DIGITAL ANNOUNCER, SINGLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPSWDHD-MW

IP DIGITAL ANNOUNCER, DOUBLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPCSHD-DS-MB

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, PRIMEX: 125-PE115G

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, LARGE SIZE

IP STROBE, WALL MOUNTED, ALGO, MULTI-COLOR: 8138

IP PA SPEAKER, CEILING MOUNTED, ADVANCED NETWORK DEVICES: IPSCM-RMe

INCLUDE BACKBOX FOR WALL MOUNT AND HARD / EXPOSED CEILING APPLICATIONS

ANALOG PA SPEAKER, CEILING MOUNTED, WITH 70V TRANSFORMER & POTENTIOMETER VOLUME CONTROL

INCLUDE BACKBOX FOR WALL MOUNT AND HARD / EXPOSED CEILING APPLICATIONS

TOUCH CONTROLLER, AUDIO ENHANCEMENT: INTERACTIVE TOUCH CONTROLLER

SOUNDFIELD SPEAKER, CEILING | WALL MOUNTED

PAGING HORN, WALL MOUNTED, AUDIO ENHANCEMENTS: SP-1091, TAP 15 WATTS

CALL BUTTON, WALL MOUNTED

SF

HN

PA

SF

ITC

CB

D3

D4

S

PA

CALL BUTTON BOX, NO CABLE / HARDWARE, WALL MOUNTED - INCLUDE STAINLESS BLANK COVER PLATE

AUDIOVISUAL SYSTEMS NEW PROJECT NOTES:

1. WHERE SHOWN, CABLE DEVICES TO LOCATIONS IDENTIFIED; DAISY-CHAIN 70V SPEAKERS/HORNS WITH

COMMON HEAD END.

Owner:

Project Number: 230018

Barton Malow Builders

26500 American Drive

Southfield, MI 48034

248.436.5000 www.bartonmalow.com

Key Plan:

Scale: 1/8" = 1'

Native Page Size: 42" X 30"

0' 2' 4' 8' 16'

Project Manager: James Elliott

Drawn By: Bill Dawson, CTS

DateIssued For

Bid Package T5

Technology Systems

Troy, Michigan

REFERENCE ONLY 09/17/2026

NOT FOR CONSTRUCTION

T5.2J

2nd Floor Zone J

Audiovisual Systems

EPIC System

Athens

High School

N

AB

CD

EF

G

H

FPSFA

FP

D3

SF

SF

SF

SF

ATV

PA

XD

1A

ATV

FP

SFA

SF

SF

SF

SF

XD

ATV

FP

SFA

SF

SF

SF

SF

XD

ATV

FPSFA

SF

SF

SF

SF

XD

ATV

D3

FP

ATV

PA

1A

FP

ATV

FP

D1

FPATV

D1

FPSFA

SF

SF

SF

SF

XD

ATV

PA

PA

FP SFA

XD

SF

SF

ATV

SF

SF

PA

IDF 7

DSI

FP

ATV

ITC

ITC

D3

ITC

D3

ITC

FP ATV

D1 -

D1

PA

PA

D3 ITC

D3ITC

D1

PA

PA

FP

SFA

SF

SF

SF

SF

XD

ATV

ITC

D3

FP

SFA

SF

SF

SF

SF

XD

ATV

ITC

D3

FP

ATV

PA

1A

FP

ATV

PA

1A

FPSFA

SF

SF

SF

SF

XD

ATV

FP SFA

XD

SF

SF

ATV

SF

SF

D3 ITC

SF

SF

D3 ITC

FP SFA

XD

SF

SF

ATV

SF

SF

D3ITC

SF

SF

SF

SF

FPSFA

SF

SF

SF

SF

XD

ATV

D3ITC

FPSFA

SF

SF

SF

SF

XD

ATV

D3ITC

FP

ATV

D1 -

D1

FP

PA

PA

D1-

ZC

D2

FP SFA

XD

ATV

3C

4A

4A

4A

4A 4A

4A

4A

4A

4A

4A

3C

4A

4A

3C

4A

4A

3C

3A

3A

3C

ZONE K

ZONE L

ATV

ATV

ALL CALL GROUP ONLY

PAPA

PA

PA

PA

PA PA

TO 1st & 3rd FLOORS

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK.

CONTRACTORS SHALL PROVIDE ALL INCIDENTAL MATERIALS AND LABOR FOR A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

2. PRIOR TO BEGINNING WORK, CONTRACTORS ARE TO REVIEW BUILDING PLANS, INSTALLATION LOCATIONS, AND SITE CONDITIONS. NOTIFY THE TECHNOLOGY DESIGNER OF ANY CONDITIONS THAT MAY: PREVENT PROPER INSTALLATION AND OPTIMAL PERFORMANCE OF THE SYSTEMS; VOID THE MANUFACTURER'S WARRANTY; OR THAT CONFLICT WITH THE INTENT OF THE PROJECT. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN RESOLVED. THE CONTRACTOR IS RESPONSIBLE FOR

ANY ADDITIONAL WORK RELATED TO CORRECTING UNREPORTED CONFLICTS AND ISSUES, AT NO

ADDITIONAL COST TO THE OWNER.

3. FIELD VERIFY LOCATIONS, CONDITIONS AND LENGTHS PRIOR TO INSTALLATION.

4. CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN PENETRATIONS, SLEEVES, AND CORES THROUGH ALL

WALLS AND FLOORS. ALL SLEEVES SHALL HAVE NYLON BUSHINGS.

5. CONTRACTOR SHALL PROVIDE FIRESTOPPING ON PENETRATIONS PASSING THROUGH WALLS AND FLOORS

IN WHICH THEY WORK.

6. CONTRACTOR SHALL COORDINATE TELECOMMUNICATION ROOM LAYOUTS WITH BARTON MALOW AND ALL

IMPACTED CONTRACTORS PRIOR TO INSTALLATION.

7. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT LOCATIONS AND ROUGH-IN REQUIREMENTS WITH

BARTON MALOW AND ALL IMPACTED CONTRACTORS PRIOR TO INSTALLATIONS.

8. CONTRACTOR SHALL PROVIDE FACEPLATES, INSERTS, AND ADAPTERS AS NECESSARY FOR THEIR DEVICES TO FIT-IN AND WORK-WITH: RACEWAY; FLOOR, TABLE, AND BACK BOXES; AND ELECTRICAL OUTLETS, WHETHER EXISTING OR PROVIDED BY OTHERS.

9. CONTRACTOR SHALL PROVIDE PROTECTIVE GUARDS ON THEIR DEVICES (CLOCKS, PHONES, ACCESS

POINTS, MOTION DETECTORS, ETC.) SUBJECT TO ABUSE IN GYMNASIUMS AND NATATORIUMS.

AUDIOVISUAL & EPIC SYSTEMS LEGEND:

COLOR CODE

GREEN - AUDIOVISUAL SYSTEM DEVICE

PURPLE - IP EPIC DEVICE

BROWN - ANALOG EPIC DEVICE

CABLING OUTLET / WALL PLATE

LOCATED IN FLOOR BOX

LOCATED ON WALL, LOW HEIGHT

LOCATED ON WALL, MID HEIGHT

LOCATED ON WALL, HIGH HEIGHT

OUTLET / PLATE ABBREVIATIONS

A AUDIO PLATE: SEE SCHEMATIC

V AUDIO AND / OR VIDEO PLATE: SEE SCHEMATIC

AV LEGACY AUDIOVISUAL INTERFACE

HARDWARE

FLAT PANEL DISPLAY, CEILING OR CART MOUNTED | WALL MOUNTED, MINIMUM SIZE INDICATED

PROJECTOR, CEILING MOUNTED

APPLE TV (OWNER FURNISHED, CONTRACTOR INSTALLED), TYPICALLY CEILING MOUNTED

DISPLAY ELEVATION - SEE SHEET T9.4

SOUNDFIELD AMPLIFIER | XD RECEIVER, WALL MOUNTED

AUDIO ENHANCEMENTS: MS-700 KIT UNLESS OTHERWISE NOTED

ZONE CONTROLLER & AMPLIFIER, RACK LOCATED, AUDIO ENHANCEMENTS: CZA-1300

DOOR SENSOR INTERFACE(S), BARIX: BARIONET 50

PJ

FP

XD

DSI

ATV

SFA

ZC

FP

D1

D2

IP DIGITAL ANNOUNCER, SINGLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPSWDHD-MW

IP DIGITAL ANNOUNCER, DOUBLE FACE, WALL MOUNTED, ADVANCED NETWORK DEVICES: IPCSHD-DS-MB

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, PRIMEX: 125-PE115G

IP DIGITAL CLOCK, SINGLE FACE, WALL MOUNTED, LARGE SIZE

IP STROBE, WALL MOUNTED, ALGO, MULTI-COLOR: 8138

IP PA SPEAKER, CEILING MOUNTED, ADVANCED NETWORK DEVICES: IPSCM-RMe

INC…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .