This is Addendum Number Four to the Plans and Specifications for a demolition project issued by Corpus Christi Independent School District (CCISD) in Corpus Christi, Texas, prepared by Lamarr Womack & Associates, LP. The project involves the demolition of six school facilities: Fannin, Kostoryz, Sanders, and Travis Elementary Schools; Browne and Martin Middle Schools; and CIRC (Old Cunningham on Prescott). The addendum, dated June 17, 2026, provides clarifications, specification additions, and plan revisions to the original contract documents. Key clarifications include that contractors must provide their own bid bonds, existing storm drains must remain and be protected during demolition, and a site tour schedule would be provided in a subsequent addendum. The addendum incorporates asbestos inspection reports and abatement specifications for Fannin Elementary (prepared by Sitex, dated June 3 and 6, 2026), Kostoryz Elementary (dated June 12 and 15, 2026), and Browne Middle School (dated June 17, 2026), along with a revised demolition site plan for Old Cunningham Elementary. Contractors are required to furnish performance bonds, payment bonds, and certificates of insurance before commencing work, with work to begin within 10 days of contract execution.
The asbestos inspection report for Fannin Elementary identifies 374 samples of suspect asbestos-containing materials, with findings including floor tile mastic, floor tile, pipe insulation mastic, sink mastic, transite pipe, ceiling tile mastic, and vapor barrier containing greater than one percent asbestos. Materials are currently in good condition and non-friable; however, Sitex recommends removal of all asbestos-containing materials prior to demolition in accordance with NESHAP regulations and Texas Asbestos Health Protection Rules. The removal must be designed by a DSHS-licensed asbestos consultant, performed by DSHS-licensed abatement contractors, and monitored by a DSHS-licensed air monitoring firm. The sample quantities for asbestos-containing materials are estimates only, and contractors are required to conduct independent measurements and cost projections. Liquidated damages apply if work is not completed within the agreed timeframe, and the District reserves the right to approve changes in scope and change orders through Board of Trustees action.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM NUMBER FOUR June 17, 2026
TO THE PLANS AND SPECIFICATIONS FOR: PAGE 1 OF 549
DEMOLITION OF FANNIN, KOSTORYZ, SANDERS, AND TRAVIS
ELEMENTARY SCHOOLS, BROWNE & MARTIN MIDDLE
SCHOOLS, AND CIRC (OLD CUNNINGHAM ON PRESCOTT)
CORPUS CHRISTI INDEPENDENT SCHOOL DISTRICT
CORPUS CHRISTI, TEXAS
LAMARR WOMACK & ASSOCIATES, LP
711 N. CARANCAHUA, SUITE 404
CORPUS CHRISTI, TX 78401
361/884-7442 FAX: 361/226-4548
This addendum is generally separated into sections for convenience; however, all contractors, subcontractors, materialmen, and other parties shall be responsible for reading the entire addendum.
The failure to list an item or items in all affected sections of this addendum does not relieve any party affected from performing as per instructions, providing that the information is set forth any time, any place in this addendum. These documents shall be attached to and become a part of the contract documents for this project.
CLARIFICATION ITEMS
Item C-1 Section 00100 Instructions to All Interested Offerors, Request for Competitive
Sealed Proposal - ADD Sample – Construction Contract for informational purposes only. (3 pages)
Item C-2 Section 00100 Instructions to All Interested Offerors, Request for Competitive
Sealed Proposal - CLARIFICATION Corpus Christi Independent School District does not provide a Bid Bond form. Contractors are to provide their own Bid Bonds.
Item C-3 Section 00100 Instructions To All Interested Offerors, 15. Examination of
Contract Documents and Site, 15.2 – CLARIFICATION A site tour schedule for additional viewing of the campus sites is to follow with next addendum.
SPECIFICATION ITEMS
Item S-1 Specification 003126 Existing Hazardous Material Information, 1.1 B. – ADD and Asbestos Inspection Report for Fannin Elementary, prepared by Sitex, dated June 3, 2026, attached. (113 pages)
Item S-2 Section 003126 Existing Hazardous Material Information, 1.1 B. – ADD and
Specifications for Asbestos Abatement for Fannin Elementary, prepared by Sitex, dated June 6, 2026, attached. (56 pages)
06-17-2026
ADDENDUM NUMBER FOUR June 17, 2026
TO THE PLANS AND SPECIFICATIONS FOR: PAGE 2 OF 549
Item S-3 Specification 003126 Existing Hazardous Material Information, 1.1 B. – ADD and Asbestos Inspection Report for Kostoryz Elementary, prepared by Sitex, dated June 12, 2026, attached. (119 pages)
Item S-4 Section 003126 Existing Hazardous Material Information, 1.1 B. – ADD and
Specifications for Asbestos Abatement for Kostoryz Elementary, prepared by Sitex, dated June 15, 2026, attached. (56 pages)
Item S-5 Specification 003126 Existing Hazardous Material Information, 1.1 B. – ADD and Asbestos Inspection Report for Browne Middle School, prepared by Sitex, dated June 17, 2026, attached. (143 pages)
Item S-6 Section 003126 Existing Hazardous Material Information, 1.1 B. – ADD and
Specifications for Asbestos Abatement for Browne Middle School, prepared by Sitex, dated June 17, 2026, attached. (56 pages)
PLAN ITEMS
Item P-1 Sheets A100 thru A106 Demolition Site Plans, Site Plan General Notes, Note E.
– CLARIFICATION All existing storm drains to remain and to be protected during demolition. Locations and quantities of existing drainage structures including storm drains, manholes and inlets to be field verified by Contractor.
Item P-2 Sheets A100 thru A106 Demolition Site Plans, Existing Fences and New Fences
– CLARIFICATION Existing fences and new fences can be used for site security. Temporary fences are only as required, if new and existing fences to remain are not around perimeter of project. All fences are to be protected during demolition. Refer to related Item S-5 on Addendum 2.
The entire campus property and existing perimeter fence are not shown on all sheets. The existing fences not shown on some of the plans continue around to enclose the perimeter of each campus.
Item P-3 Sheet A106 Demolition Site Plan, Old Cunningham Elementary – REPLACE sheet with attached revised sheet, Addendum 4. (1 page)
SAMPLE - CONSTRUCTION CONTRACT
THE STATE OF TEXAS §
COUNTY OF NUECES §
The CORPUS CHRISTI INDEPENDENT SCHOOL DISTRICT (hereafter called “Owner”) and _______________________ (hereafter called “Contractor”), hereby agree as follows:
1. Contractor agrees to construct for Owner in accord with the Contract Documents the following: __(“Project”), according to the contract documents prepared by (“Engineer”).
2. Contractor agrees to furnish, at his own expense, all labor, services, materials, tools, equipment and supervision necessary to the full and final completion of the Project, and everything incidental thereto, as shown on the Drawings, stated in the Specifications, or properly inferable therefrom, all in accord with the Contract Documents, as hereafter defined.
3. The Contract Documents consist of this Construction Contract and the following instruments, which are incorporated herein:
a. Request For Competitive Sealed Proposals # FYXX-P-00XX Included in the Project Manual
b. Proposal response
c. Conditions of the Contract (General and Supplemental)
d. Drawings
e. Specifications
f. Addenda and amendments to the foregoing as follows:
(1) Addendum No. 1 dated ________
(2) Addendum No. 2 dated ________
4. Immediately following the execution of this contract and before performing any work, Contractor shall furnish to Owner a valid Performance Bond and Payment Bond, each in the full amount of the contract price on forms promulgated by Owner, written by companies acceptable to and approved by Owner and a required Certificate of Insurance, each in accord with the requirements of the Contract Documents.
5. Contractor shall commence work on or before 10 days from the effective date of this Contract and shall complete the work on or before . Time is of the essence in all phases of the work. If the work is not timely completed in accord with the terms of the Contract Documents, Contractor shall be liable to Owner for damages calculated in accord with the terms and provisions of Article 13 of the Supplemental General Conditions of the Contract. If liquidated damages are assessed according to Article 13, it is expressly agreed that the said sum per day is a fair estimate of the pecuniary damages which will be sustained by the Owner in the event that the work is not completed within the agreed time. Said sum shall be considered as liquidated damages only and in no sense shall be considered a penalty, said damages being caused by additional compensation to personnel, for loss of interest on money, and other miscellaneous increased costs, all of which are difficult to exactly ascertain. Such liquidated damages, if assessed, shall be in addition to, and not in lieu of any other rights or remedies Owner may have against Contractor for failure to timely achieve completion of the work.
6. The total contract price is $_________ dollars ($), which includes the base bid and alternates numbers: N/A.
7. The parties hereto agree that they will take such steps and execute such instruments as may be necessary to enable Owner to claim its exemption from the State of Texas Limited Sales Tax for Materials used in such Project. All savings resulting from such tax exemption shall be for the benefit of the Owner.
6. The Board of Trustees, by majority vote, is the only representative of the
Owner, an independent school district having the power to enter into a contact to approve changes in the scope of the work to approve a change order, or to agree to an extension to the date of completion of the work. The Board may authorize a representative to act on behalf of the Owner in the day-to-day administration of the contract.
Executed in Corpus Christi, Texas, on __________, 202X.
ATTEST: CORPUS CHRISTI INDEPENDENT SCHOOL DISTRICT
By: Date:
President, Board of Trustees
Dr. Roland Hernandez Superintendent of Schools
Reviewed and Approved for Purchasing Compliance
Arnulfo Gonzalez
Director for Purchasing and Distribution
Approved as to legal form:
Brian S. Nelson General Counsel for CCISD
ABC Company 1234 XYZ Street, Corpus Christi, TX 78408
(361) 123-4567
Owner
HOUSTON • CORPUS CHRISTI
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
Asbestos Inspection Report
June 3, 2026
FANNIN ELEMENTARY SCHOOL
2730 GOLLIHAR RD
CORPUS CHRISTI, TEXAS
Prepared for:
CORPUS CHRISTI INDEPENDENT SCHOOL DISTRICT
Prepared by:
SITEX, INC
5233 IH 37 SUITE A-3
CORPUS CHRISTI, TEXAS 78408
(361) 887-9400
PROJECT NUMBER: 23958
June 3, 2026
Mr. Trent Wagner Executive Director of Construction and Project Management Corpus Christi Independent School District 801 Leopard Street Corpus Christi, TX 78401
RE: Asbestos Demolition Inspection Fannin Elementary School 2730 Gollihar Corpus Christi, TX Project Number: 23958
Dear Mr. Wagner:
Enclosed is the report for the asbestos inspection performed at 2730 Gollihar in Corpus Christi, TX. The sampling was performed on May 19 to 25, 2026, by Mr. Paul Kass of Sitex, Inc. Mr. Kass is licensed by the Texas Department of State Health Services as an Asbestos Inspector (#60-2824).
SCOPE OF WORK
The scope of this project was limited to suspect asbestos-containing materials (ACM) specified by the client at the above-referenced property. Three hundred seventy four (374) samples of suspect asbestos-containing materials were collected. State of Texas regulations define asbestos-containing materials as having greater than one per-cent (>1%) asbestos content. Samples of the following materials were found to contain greater than one percent (>1%) asbestos:
1) Floor tile mastic
2) Floor tile
3) Pipe Insulation Mastic
4) Sink Mastic
5) Transite pipe
6) Ceiling tile mastic
7) Vapor barrier
Sink mastic, floor tile mastic and window glaze included in the samples collected in the facility was found to con-tain less than one percent (< 1%) asbestos by approved laboratory analytical methods. In the State of Texas, a material must contain greater than one percent (> 1%) asbestos to be considered as a regulated material. Based upon Environmental Protection Agency (EPA) and Texas Department of State Health Services (DSHS) regula-tions, the sample is less than one percent (< 1%) asbestos and is not defined as an asbestos-containing material by rule, is not regulated by DSHS, and does not require abatement prior to the demolition or renovation of the existing structure.
However, Occupational Safety and Health Administration (OSHA) regulations regarding asbestos fiber exposure to workers does apply to materials containing less than one percent (< 1%) asbestos. The OSHA regulation re-quires each employer to determine the proper respiratory protection for employees, based upon reliable air mon-itoring data. Each employer should evaluate the respiratory hazards based upon their own health and safety programs, which are developed to comply with the current OSHA respiratory requirements. Sitex recommends wet methods, engineering controls during demolition activities, and employee air monitoring to determine proper respiratory protection when dealing with materials containing less than one percent (< 1%) asbestos.
Suspect Materials Tested
Suspect asbestos-containing materials (ACM) were collected according to protocol established by the Texas As-bestos Health Protection Rules (TAHPR) 295.34 (c) for building demolitions and renovations. During the inspection, sampled materials were assigned a sample number and a homogenous area (H.A.) number. Samples were col-lected of each area and the friability and condition of the suspect material was assessed.
Table 1 contains the homogenous area numbers, material types, material descriptions, material locations, condi-tion assessments, and a summary of the analytical results.
Table 2 correlates each sample number to its homogenous area number. Analytical results and a list of definitions can be found following the text of this report.
Analytical Methods
All polarized light microscopy (PLM) lab analyses were performed at SanAir Technologies Laboratory Inc. in North Chesterfield, VA, using standard oil immersion and optical staining techniques. SanAir is an American Industrial Hygiene Association participant laboratory (#162952), a National Institute of Standards and Technology NVLAP-accredited laboratory (#200870) and licensed by the Texas Department of State Health Services (#30-0440) for asbestos laboratory analysis.
RECOMMENDATIONS
Recommendations concerning the asbestos-containing materials (ACM) identified in this limited inspection are based on the following:
1. Condition
2. Friability
3. Potential for disturbance
Condition and Friability
The asbestos-containing floor tile, mastic, vapor barrier, pipe insulation mastic, sink mastic, ceiling tile mastic are in good condition and considered non-friable.
Response Actions
Sitex, Inc. recommends that the condition of these asbestos-containing materials should be monitored. If this material becomes damaged or will be disturbed during renovations, then this material should be removed.
Response Actions for Demolition
According to NESHAP 40 CFR 61 Subpart M, 61.145 and Texas Asbestos Health Protection Rules, 295.60, friable or potentially friable ACM which will be disturbed during demolition, or has the potential to be disturbed, must be removed. Thus Sitex, Inc. recommends that all asbestos-containing materials be removed from the building prior to demolition. A licensed asbestos consultant should be consulted prior to any demolition operations in a building or other structure containing ACM. The project must be designed by a DSHS (Department of State Health Services) licensed asbestos consultant and monitored by a DSHS licensed company.
Use of Licensed Contractors
According to the Texas Asbestos Health Protection Rules, 295.34, the removal of asbestos in projects covered by the regulations require asbestos abatement specifications to be written by a DSHS licensed asbestos consultant and air monitoring be performed by a DSHS licensed air monitoring firm. In addition, a DSHS licensed asbestos abatement contractor must perform the removal.
Upon request from the Client, Sitex, Inc. can develop asbestos abatement specifications and obtain removal bids from multiple licensed abatement contractors. Please contact Stacy Kraatz at 361-887-9400 or by email at sta-cyk@sitexsolutions.com if this service is desired.
DISCLAIMER
The quantities for the asbestos-containing materials (ACM) indicated in Table I of this report (below) are estimates only, based upon scaled diagrams provided by the client and on-site evaluations. Sitex, Inc. assumes no liability for the use or interpretation of said quantities by any subsequent contractors, including, but not limited to, mailto:stacyk@sitexsolutions.com mailto:stacyk@sitexsolutions.com logistical issues, cost overruns and/or budgeting problems. Contractors bidding on removal of these materials should determine and develop cost projections based on their own independent measurements and quantifica-tions.
LIMITATIONS
This sampling report does not guarantee that additional asbestos-containing materials are not present. The scope of this project was limited to the client-specified materials sampled within this report. All other portions of the building not designated in the Scope of Work were specifically excluded. This report does not constitute a com-prehensive asbestos survey.
The following analytical results pertain to only the samples analyzed and may not reflect the actual composition of the entire homogeneous area. Sitex, Inc. assumes no responsibility for any subsequent use or interpretations of these analytical results. This report must not be used to claim product endorsement by NVLAP or any other state or federal government agency.
Please call us if you have any questions regarding this inspection report. We appreciate the opportunity to be of service to you.
Sincerely, Stacy Kraatz Paul Kass Asbestos Consultant (#10-5874) Asbestos Inspector (#60-2824) South Texas Regional Manager Sitex, Inc.
Sitex, Inc.
List of Definitions
Asbestos-Containing Material (ACM) - any material containing more than one percent asbestos (chrysotile asbes-tos, amosite asbestos, crocidolite asbestos, tremolite asbestos, anthophyllite asbestos, actinolite asbestos).
Demolition - the wrecking or taking out of any load-supporting structure member and any related razing, remov-ing, or stripping of asbestos products.
Disturbance - contact which releases fibers from ACM or debris containing ACM including activities which that disrupts the matrix of ACM, render ACM friable, or generate visible debris.
Encapsulation - a method of control of asbestos fibers in which the surface of ACM is penetrated by or covered with a liquid coating prepared for that purpose.
Enclosure - the construction of an airtight, impermeable, semi-permanent barrier surrounding asbestos to prevent the release of asbestos fibers into the air.
Fiber - a particulate form of asbestos, 5 micrometers or longer, with a length-to diameter ratio of at least 3 to 1.
Friable Materials - any material that when dry can be crumbled, pulverized, or reduced to powder by hand pres-sure.
Homogeneous Area - an area of surfacing material or thermal system that is uniform in color and texture.
Intact - means that the ACM has not crumbled, been pulverized, or otherwise deteriorated so that it is no longer likely to be bound with its matrix.
Removal - all operations where ACM is taken out or stripped from structures or substrates, and includes demoli-tion operations.
Renovation - the modifying of any existing structure, or portion thereof.
Repair - overhauling, rebuilding, reconstructing, or reconditioning of structures or substrates, including encapsu-lation or other repair of ACM attached to structures or substrates.
Table I – Sample Materials Summary
Table II – Sample Location / Homogeneous Area Association
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
TABLE I - SAMPLE MATERIALS SUMMARY
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
1 Floor Tile 12x12 White W/Blue Streaks Rooms 1-5,7,8 (Approx 4550 sf) Good No No
2 Floor Tile Mastic Yellow/Brown Rooms 1-5,7,8 (Approx 4550 sf) Good No No
3 Sheet Vinyl Teal Fibrous Material Rooms 1-16 (Approx 384 sf) Good No No
4 Sheet Vinyl Mas-tic
Yellow/Brown Mastic Rooms 1-16 (Approx 384 sf) Good No No
5 Sink Mastic Black Mastic Rooms 1-16 (16 Sinks) Good No No (<1%)
6 Pipe Insulation Mastic
White Mastic Inside Building Below Rooftop Units (Approx 250 ln ft)
Good No YES
7 Drywall White Powder W/Brown Fi-ber
Rooms 1-16, Restrooms (Ap-prox 2566 sf)
Good Yes No
8 Joint Compound White Powder Rooms 1-16, Restrooms (Ap-prox 2566 sf)
Good Yes No
9 Floor Tile 12x12 Cream W/Brown Streaks
Hallways of Rooms 1-16 and Rooms 13-16 (Approx 3250 sf)
Good No No
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
10 Floor Tile Mastic Yellow/Brown Mastic Hallways of Rooms 1-16 and
Rooms 13-16 (Approx 3250 sf) Good No No
11 Ceiling Tile 2x4 Grey Fiber W/White Paint
Hallways and Classrooms of 1-
Good Yes No
12 Carpet Mastic Yellow/Black Mastic Under Carpet of Admin Offices (Approx 1889 sf)
Good No No
13 Sheet Flooring Teal Office Restrooms (Approx 36 sf)
Good No No
14 Sheet Mastic Yellow/Brown Mastic Office Restrooms (Approx 36 sf)
Good No No
15 Sheet Flooring Brown Speck Nurse Restroom (Approx 25 sf) Good No No
16 Sheet Flooring Mastic
Yellow Mastic Nurse Restroom (Approx 25 sf) Good No No
17 Floor Tile 12x12 Cream W/Bronw Flecks
Nurse Office & Closet (Approx 150 sf)
Good No No
18 Floor Tile Mastic Yellow Mastic Nurse Office & Closet (Approx 150 sf)
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
19 Floor Tile 12x12 Cream W/Bronw
Flecks Under Carpet of Lounge (Ap-prox 384 sf)
Good No Yes
20 Floor Tile Mastic Black Mastic Under Carpet of Lounge (Ap-prox 384 sf)
Good No Yes
21 Sink Mastic
Pink Mastic Lounge Sink Good No Yes
22 Sink Mastic Black Mastic Teacher’s Work Room Good No Yes
23 Refractory Ce-ment
White Cementous Material Room 33 Kiln Good No No
24 Transite Pipe Grey Cementous Material Kitchen (Approx. 5 lf) Good No Yes
25 Carpet Mastic Yellow/Green Mastic Under Carpet of Room 33 (Ap-prox. 882 sf)
Good No No
26 Carpet Mastic Yellow/Green Mastic Under Carpet of Library (Ap-prox. 1404 sf)
27 Sink Mastic Grey Mastic Rooms 21,25,34 Good No YES
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
28 Sink Mastic Black Mastic Rooms 17-20,22-24,26-302 Good No No
(<1%) 29 Cove Base Mastic Tan/Black Mastic Perimeter of Halls and Class-rooms of West Building Good No No
30 Ceiling Tile 2x4 Grey Fiber W/White Paint
Suspended Ceiling of West Half of Building
Good Yes No
31 Ceiling Tile 2x4 Grey Fiber W/White Paint
Suspended Ceiling of West Half of Building
Good Yes No
32 Drywall White Powder W/Brown Fi-ber
RR Ceilings, Fur downs of Rooms 17-32, Rooms and Hall-ways of 33-35 (Approx 3020 sf)
Good Yes No
33 Floor Tile 12x12 Cream W/Tan Streaks Hallways, Library Storage, Workroom, Rms 17-32,34,35 (Approx. 11,200 sf)
Good No No
34 Floor Tile Mastic Yellow/Brown/ Black Mastic Hallways, Library Storage, Workroom, Rms 17-32,34,35 (Approx. 11,200 sf)
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
35 Floor Tile 12x12 Yellow W/Yellow
Streaks Designs of Hallways, Library Storage, Workroom, Rms 17- 32,34,35 (Approx 950 sf)
Good No No
36 Floor Tile 12x12 Yellow W/Yellow Streaks
Designs of Hallways, Library Storage, Workroom, Rms 17- 32,34,35 (Approx 950 sf)
Good No No
37 Floor Tile Mastic Yellow/Brown/ Black Mastic Designs of Hallways, Library Storage, Workroom, Rms 17- 32,34,35 (Approx 950 sf)
Good No No
38 Floor Tile Mastic Yellow/Brown/ Black Mastic Designs of Hallways, Library Storage, Workroom, Rms 17- 32,34,35 (Approx 950 sf)
Good No No
39 Floor Tile 12x12 Lt. Blue W/Blue Streaks
Designs of Hallways, Library Storage, Workroom, Rms 17- 32,34,35 (Approx 950 sf)
Good No No
40 Floor Tile Mastic Yellow/Brown/ Black Mastic Designs of Hallways, Library Storage, Workroom, Rms 17- 32,34,35 (Approx 950 sf)
41 Floor Tile 12x12 Cream W/Tan Streaks Room 35,36 (Approx 1394 sf) Good No No
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
42 Floor Tile Mastic Yellow/Black Mastic Room 35,36 (Approx 1394 sf) Good No No
(<1%) 43 Floor Tile 12x12 Yellow W/Cream
Streaks Design of Room 35,36 (Approx 55 sf)
Good No No
44 Floor Tile Mastic Yellow/Black Mastic Design of Room 35,36 (Approx 55 sf)
Good No No (<1%)
45 Floor Tile 12x12 Dk. Blue W/Lt. Blue Streaks
Design of Room 35,36 (Approx 55 sf)
Good No No
46 Floor Tile Mastic Yellow/Black Mastic Design of Room 35,36 (Approx 55 sf)
Good No No (<1%)
47 Sink Mastic Grey Mastic Sinks of 35,36 Good No No
48 Ceiling Tile 2x4 Grey Fiber W/White Paint
Suspended Ceiling of 35,36 Good Yes No
49 Sheet Vinyl Tan Pebble Design Restrooms of 35,36 (Approx 64 sf)
Good No No
50 Sheet Vinyl Mas-tic
Yellow/Bronw Mastic Restrooms of 35,36 (Approx 64 sf)
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
51 Ceiling Tile 2x4 Grey Fiber W/White
Paint Rooms 37,38 Good Yes No
52 Sink Mastic White Mastic Sinks of 37,38 Good No No
53 Sheet Vinyl Tan Pebble Design Restrooms of 37,38 (Approx 64 sf)
Good No No
54 Sheet Vinyl Mas-tic
Yellow/Bronw Mastic Restrooms of 37,38 (Approx 64 sf)
Good No No
55 Floor Tile 12x12 Cream W/Brown Streaks
Rooms 37,38 (Approx 692 sf) Good No No
56 Floor Tile Mastic Yellow/Brown Mastic Rooms 37,38 (Approx 692 sf) Good No No
57 Floor Tile 12x12 Lt. Blue W/Dk. Blue Streaks
Design of Rooms 37,38 (Approx 20 sf)
Good No No
58 Floor Tile Mastic Yellow/Brown Mastic Design of Rooms 37,38 (Approx 20 sf)
Good No No
59 Floor Tile 12x12 Yellow W/Lt. Yellow Streaks
Design of Rooms 37,38 (Approx 20 sf)
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
60 Floor Tile Mastic Yellow/Brown Mastic Design of Rooms 37,38 (Approx
20 sf) Good No No
61 Floor Tile 12x12 Dk. Blue W/Lt. Blue Streaks
Design of Rooms 37,38 (Approx 20 sf)
Good No No
62 Floor Tile Mastic Yellow/Brown Mastic Design of Rooms 37,38 (Approx 20 sf)
Good No No
63 Floor Tile 12x12 White W/Blue Streaks Room 37 (Approx 692 sf) Good No No
64 Floor Tile Mastic Yellow/Brown Mastic Room 37 (Approx 692 sf) Good No No
65 Floor Tile 12x12 Orange W/Brown Streaks
Design of Room 37 (Approx 20 sf)
Good No No
66 Floor Tile Mastic Yellow/Brown Mastic Design of Room 37 (Approx 20 sf)
Good No No
67 Floor Tile 12x12 Blue W/Dk. Blue Streaks
Design of Room 37 (Approx 20 sf)
Good No No
68 Floor Tile Mastic Yellow/Brown Mastic Design of Room 37 (Approx 20
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
69 Floor Tile 12x12 Purple W/Dk. Purple
Streaks Design of Room 37 (Approx 20 sf)
Good No No
70 Floor Tile Mastic Yellow/Brown Mastic Design of Room 37 (Approx 20 sf)
Good No No
71 Floor Tile 12x12 Green W/Dk. Green Streaks
Design of Room 37 (Approx 20 sf)
Good No No
72 Floor Tile Mastic Yellow/Brown Mastic Design of Room 37 (Approx 20 sf)
Good No No
73 Ceiling Tile 2x4 Grey Fiber W/White Paint
Rooms 37,38 Good Yes No
74 Sink Mastic Grey Mastic Sink in 40 Good No No
75 Sheet Vinyl Teal W/White Swirl Pattern Restroom (Approx 100 sf) Good No No
76 Sheet Vinyl Mas-tic
Yellow/Brown Mastic Restroom (Approx 100 sf) Good No No
77 Floor Tile 12x12 Cream W/Brown Streaks
Rooms 39,40 (Approx 1376 sf) Good No No
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
78 Floor Tile Mastic Yellow/Brown Mastic Rooms 39,40 (Approx 1376 sf) Good No No
79 Floor Tile 12x12 Blue W/Dk Blue Streaks
Rooms 39,40 (Approx 20 sf) Good No No
80 Floor Tile Mastic Yellow/Brown Mastic Rooms 39,40 (Approx 20 sf) Good No No
81 Floor Tile 12x12 Dk Blue W/Lt. Blue Streaks
Rooms 39,40 (Approx 20 sf) Good No No
82 Floor Tile Mastic Yellow/Brown Mastic Rooms 39,40 (Approx 20 sf) Good No No
83 Floor Tile 12x12 Yellow W/Dk. Yellow Streaks
Rooms 39,40 (Approx 20 sf) Good No No
84 Floor Tile Mastic Yellow/Brown Mastic Rooms 39,40 (Approx 20 sf) Good No No
85 Ceiling Tile 2x4 Grey Fiber W/White Paint
Cafeteria and Storage Good Yes No
86 Ceiling Tile 12x12 Tan Fiber W/White Paint
Cafeteria and Stage Above Sus-pended Ceiling (Approx. 3986
Good Yes No
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
87 Ceiling Tile Mas-tic Brown/Black/Tan Cafeteria and Stage Above Sus-pended Ceiling (Approx. 3986 sf)
Good No YES
88 Floor Tile 12x12 Blue Tile Border of Cafeteria (Approx.
492 sf)
Good No No
89 Floor Tile Mastic Yellow/Brown Mastic Border of Cafeteria (Approx.
492 sf)
Good No No
90 Floor Tile 12x12 Cream W/Brown Streaks
Cafeteria (Approx. 2758 sf) Good No No
91 Floor Tile Mastic Brown Mastic Cafeteria (Approx. 2758 sf) Good No No
92 Windowpane Glaze
Tan/White Powder Cafeteria Windowpanes (Ap-prox. 47 Windows
Good No No (<1%)
93 Door Sealant White/Tan Cafeteria Door Frames Good No No
94 Vapor Barrier Black Fibrous Mastic South Wall of Cafeteria (Approx 40 lf)
Good No No
95 Vapor Barrier Black Fibrous Mastic Main Building (Approx 11340
Good No YES
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400 • Fax 361.887.9401 • www.envirotestllc.com
2730 Gollihar Rd, Corpus Christi, TX
H.A.* MATERIAL
NAME MATERIAL DESCRIPTION MATERIAL LOCATION CONDITION FRIABLE
ASBESTOS-
CONTAINING
MATERIAL
96 Door Sealant White Bituminous Material Exterior Doors of Main Building Good No No
97 Brick Seam Seal-ant
Grey Bituminous Material Exterior Brick Expansion Seams Good No No
98 Sheet Roofing Black Fiber W/Black Tar and White Pebbles
Roof of Rooms 39-40 Good No No
99 Sheet Roofing Black Fiber W/Black Tar and White Pebbles
Roof of Rooms 35-36 Good No No
100 Sheet Roofing Black Fiber W/Black Tar and White Pebbles
Roof of Rooms 37-38 Good No No
101 Sheet Roofing Black Fiber W/Black Tar and White Pebbles
Roof of Rooms 33-34 Good No No
102 Roofing Black Tar Main Building Roof Good No No
103 Curb Roofing Black Fiber W/White Pebbles and Black Tar
Main Roof Curbs Good No No
* Homogeneous Area
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
TABLE II: SAMPLE NUMBER ⇔ HOMOGENEOUS AREA
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
1. 1 Room 2
2. 1 Room 3
3. 1 Room 4
4. 1 Room 6
5. 1 Room 7
6. 2 Room 2
7. 2 Room 3
8. 2 Room 4
9. 2 Room 6
10. 2 Room 7
11. 3 Room 3
12. 3 Room 6
13. 3 Room 10
14. 4 Room 3
15. 4 Room 6
16. 4 Room 10
17. 5 Room 3
18. 5 Room 6
19. 5 Room 14
20. 6 Room 6
21. 7 Room 3
22. 7 Room 6
23. 7 Room 10
24. 7 Room 11
25. 7 Room 14
26. 8 Room 3
27. 8 Room 6
28. 8 Room 10
29. 8 Room 11
30. 8 Room 14
31. 9 Hallway @ Room 6
32. 9 Room10
33. 9 Room 11
34. 9 Hallway @ Room 13
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
35. 9 Room 14
36. 10 Hallway @ Room 6
37. 10 Room10
38. 10 Room 11
39. 10 Hallway @ Room 13
40. 10 Room 14
41. 11 Hallway @ Restroom
42. 11 Room 2
43. 11 Hallway @ Room 6
44. 11 Room 6
45. 11 Hallway @ Room 8
46. 11 Room 10
47. 11 Room 16
48. 12 Reception
49. 12 Assistant Principal
50. 12 Principal
51. 12 Police
52. 12 Conference
53. 13 Restroom 2
54. 13 Restroom 2
55. 13 Restroom 1
56. 14 Restroom 2
57. 14 Restroom 2
58. 14 Restroom 1
59. 15 Nurse Restroom
60. 15 Nurse Restroom
61. 15 Nurse Restroom
62. 16 Nurse Restroom
63. 16 Nurse Restroom
64. 16 Nurse Restroom
65. 17 Nurse Office
66. 17 Nurse Office
67. 17 Nurse Office
68. 18 Nurse Office
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
69. 18 Nurse Office
70. 18 Nurse Office
71. 19 Lounge
72. 19 Lounge
73. 19 Lounge
74. 20 Lounge
75. 20 Lounge
76. 20 Lounge
77. 21 Lounge
78. 22 Teacher’s Work Room
79. 23 Room 33 Kiln
80. 24 Kitchen
81. 25 Room 33
82. 25 Room 33
83. 25 Room 33
84. 26 Library
85. 26 Library
86. 26 Library
87. 27 Room 87
88. 27 Room 88
89. 27 Room 89
90. 28 Room 17
91. 28 Room 23
92. 28 Room 26
93. 28 Room 29
94. 29 Teacher’s Work Room
95. 29 Room 17
96. 29 Room 21
97. 29 Room 25
98. 29 Room 29
99. 29 Room 34
100. 29 Hallway @ Room 21
101. 30 Teacher’s Work Room
102. 30 Room 17
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
103. 30 Room 21
104. 30 Room 25
105. 30 Room 29
106. 30 Room 34
107. 30 Hallway @ Room 21
108. 31 Room 17
109. 31 Room 21
110. 31 Room 25
111. 31 Room 29
112. 31 Room 33
113. 31 Room 34
114. 31 Boy’s RR
115. 32 Room 17
116. 32 Room 21
117. 32 Room 25
118. 32 Room 29
119. 32 Room 33
120. 32 Room 34
121. 32 Boy’s RR
122. 33 Workroom
123. 33 Room17
124. 33 Room 21
125. 33 Room 25
126. 33 Room 29
127. 33 Room 34
128. 33 Hallway @ Room 21
129. 34 Workroom
130. 34 Room17
131. 34 Room 21
132. 34 Room 25
133. 34 Room 29
134. 34 Room 34
135. 34 Hallway @ Room 21
136. 35 Workroom
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
137. 35 Room17
138. 35 Room 21
139. 35 Room 25
140. 35 Room 29
141. 35 Room 34
142. 35 Hallway @ Room 21
143. 36 Workroom
144. 36 Room17
145. 36 Room 21
146. 36 Room 25
147. 36 Room 29
148. 36 Room 34
149. 36 Hallway @ Room 21
150. 37 Teacher’s Workroom
151. 37 Room17
152. 37 Room 21
153. 37 Room 25
154. 37 Room 29
155. 37 Room 34
156. 37 Hallway @ Room 21
157. 37 Workroom
158. 38 Room17
159. 38 Room 21
160. 38 Room 25
161. 38 Room 29
162. 38 Room 34
163. 38 Hallway @ Room 21
164. 39 Teacher’s Workroom
165. 39 Room17
166. 39 Room 21
167. 39 Room 25
168. 39 Room 29
169. 39 Room 34
170. 39 Hallway @ Room 21
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
171. 40 Workroom
172. 40 Room17
173. 40 Room 21
174. 40 Room 25
175. 40 Room 29
176. 40 Room 34
177. 40 Hallway @ Room 21
178. 41 Room 35
179. 41 Room 36
180. 41 Room 36
181. 42 Room 35
182. 42 Room 36
183. 42 Room 36
184. 43 Room 35
185. 43 Room 36
186. 43 Room 36
187. 44 Room 35
188. 44 Room 36
189. 44 Room 36
190. 45 Room 35
191. 45 Room 36
192. 45 Room 36
193. 46 Room 35
194. 46 Room 36
195. 46 Room 36
196. 47 Room 35
197. 47 Room 35
198. 47 Room 36
199. 48 Room 35
200. 48 Room 35
201. 48 Room 36
202. 49 Room 35
203. 49 Room 35
204. 49 Room 36
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
205. 50 Room 36
206. 50 Room 36
207. 50 Room 36
208. 51 Room 37
209. 51 Room 38
210. 51 Room 38
211. 52 Room 37
212. 52 Room 37
213. 52 Room 37
214. 53 Room 37
215. 53 Room 38
216. 53 Room 38
217. 54 Room 37
218. 54 Room 38
219. 54 Room 38
220. 55 Room 38
221. 55 Room 38
222. 55 Room 38
223. 56 Room 38
224. 56 Room 38
225. 56 Room 38
226. 57 Room 38
227. 57 Room 38
228. 57 Room 38
229. 58 Room 38
230. 58 Room 38
231. 58 Room 38
232. 59 Room 38
233. 59 Room 38
234. 59 Room 38
235. 60 Room 38
236. 60 Room 38
237. 60 Room 38
238. 61 Room 38
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
239. 61 Room 38
240. 61 Room 38
241. 62 Room 38
242. 62 Room 38
243. 62 Room 38
244. 63 Room 37
245. 63 Room 37
246. 63 Room 37
247. 64 Room 37
248. 64 Room 37
249. 64 Room 37
250. 65 Room 37
251. 65 Room 37
252. 65 Room 37
253. 66 Room 37
254. 66 Room 37
255. 66 Room 37
256. 67 Room 37
257. 67 Room 37
258. 67 Room 37
259. 68 Room 37
260. 68 Room 37
261. 68 Room 37
262. 69 Room 37
263. 69 Room 37
264. 69 Room 37
265. 70 Room 37
266. 70 Room 37
267. 70 Room 37
268. 71 Room 37
269. 71 Room 37
270. 71 Room 37
271. 72 Room 37
272. 72 Room 37
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
273. 72 Room 37
274. 73 Room 39
275. 73 Room 39
276. 73 Room 40
277. 74 Room 40
278. 74 Room 40
279. 74 Room 40
280. 75 Restroom
281. 75 Restroom
282. 75 Restroom
283. 76 Restroom
284. 76 Restroom
285. 76 Restroom
286. 77 Room 39
287. 77 Room 39
288. 77 Room 40
289. 78 Room 39
290. 78 Room 39
291. 78 Room 40
292. 79 Room 39
293. 79 Room 39
294. 79 Room 40
295. 80 Room 39
296. 80 Room 39
297. 80 Room 40
298. 81 Room 39
299. 81 Room 39
300. 81 Room 40
301. 82 Room 39
302. 82 Room 39
303. 82 Room 40
304. 83 Room 39
305. 83 Room 39
306. 83 Room 40
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
307. 84 Room 39
308. 84 Room 39
309. 84 Room 40
310. 85 Cafeteria
311. 85 Cafeteria
312. 85 Cafeteria
313. 85 Cafeteria
314. 85 Cafeteria
315. 86 Cafeteria
316. 86 Cafeteria
317. 86 Cafeteria
318. 86 Cafeteria
319. 86 Cafeteria
320. 87 Cafeteria
321. 87 Cafeteria
322. 87 Cafeteria
323. 87 Cafeteria
324. 87 Cafeteria
325. 88 Cafeteria
326. 88 Cafeteria
327. 88 Cafeteria
328. 89 Cafeteria
329. 89 Cafeteria
330. 89 Cafeteria
331. 90 Cafeteria
332. 90 Cafeteria
333. 90 Cafeteria
334. 90 Cafeteria
335. 90 Cafeteria
336. 91 Cafeteria
337. 91 Cafeteria
338. 91 Cafeteria
339. 91 Cafeteria
340. 91 Cafeteria
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
341. 92 Cafeteria
342. 92 Cafeteria
343. 92 Cafeteria
344. 93 Cafeteria
345. 93 Cafeteria
346. 93 Cafeteria
347. 94 South Cafeteria Wall
348. 95 Outside Room 32
349. 95 Outside Room 20
350. 95 Outside Room 9
351. 96 Door a @ Room 32
352. 96 Door a @ Room 9
353. 96 Door a @ Room 5
354. 97
Exterior @ Room 32
355. 97
Exterior @ Room 11
356. 97
Exterior @ Room 5
357. 98 Roof of 39
358. 98 Roof of 39
359. 98 Roof of 40
360. 99 Roof of 35
361. 99 Roof of 35
362. 99 Roof of 36
363. 100 Roof of 37
364. 100 Roof of 38
365. 100 Roof of 38
366. 101 Roof of 33
367. 101 Roof of 34
368. 101 Roof of 34
369. 102 Roof Above Room 32
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
2730 Gollihar Rd, Corpus Christi, TX
SAMPLE # H.A.* SAMPLE LOCATION
370. 102 Roof Above Library
371. 102 Roof Above Cafeteria
372. 103 Curb Above Room 32
373. 103 Curb Above Library
374. 103 Curb Above Cafeteria
* Homogeneous Area
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
Sample Location Diagrams
280,281,282 283,284,285
23,28 32,37
25,30 35,40
5,10 13,16
4,9 12,15,18 20,23,27
3,8 2,7,11,14,17 21,26
1,6,43
350,355
31,36,43
34,39
24,29 33,38
55,58
53,54 56,57
81,82,83 112,119
79,89
94,101,122,129, 136,143 150,157 164,171
59,60,61 62,63,64
65,66,67 68,69,70
71,72,73 74,75,76
84,85,86 370,373 353,356
341,344
100,107,128,135 142,149,156,163
170,177
88,97,104, 110,117,125, 132,139,146 153,160, 167 174
95,102,108,115 123,130,137,14 4,151,158,165, 87,96,103 109,116,124, 131,138,145 152,159 166,173
274,275,286,287, 289,290,292,293, 295,296,298,299, 301,302,304,305, 307,308,357,358
276,277,278,279, 288,291,294,297, 300,303,306,309, 179,180,182,183 185,186,188,189 191,192,194,195, 198,201,204,207, 178,181,184,187, 190,193,196,197, 199,200,202,203 205,206,360,361, 114,121
99,106,113,120, 127,134,141,148, 155,162,367,368
98,105,111,118 126,133,140,147 154,161,168,175
208,211,214,217,244, 245,246,247,248,249, 250,251,252,253,254, 255,256,257,258,259, 260,261,262,263,264, 265,266,267,268,269, 270,271,272,273,363
209,210,212,213,215, 216,218,219,220,221, 222,223,224,225,226, 227,228,229,230,231, 232,233,234,235,236, 237,238,239,240,241, 242,243,364,365
310,311,312,313,314, 315,316,317,318,319, 320,321,322,323,324, 325,326,327,328,329, 330,331,332,333,334, 335,336,337,338,339, 340, 343,346 342,345
348,351,354
371,374
369,372
CORPUS CHRISTI OFFICE: 5233 IH 37 Suite A-3 • Corpus Christi, Texas 78408 • Voice 361.887.9400
Polarized Light Microscopy Laboratory Analytical Results
SanAir ID#: 26031190
Project #: 23958 Project Name: CCISD Fannin Elementary Report Date: 6/2/2026
Analysis Report prepared for SITEX Inc.
Dear M.P. Kass, We at SanAir would like to thank you for the work you recently submitted. The 374 sample(s) were received on Thursday, May 28, 2026 via FedEx. The final report(s) is enclosed for the following sample(s): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 90, 91, 92, 93, 94, 95, 96, 97, 98, 99, 100, 101, 102, 103, 104, 105, 106, 107, 108, 109, 110, 111, 112, 113, 114, 115, 116, 117, 118, 119, 120, 121, 122, 123, 124, 125, 126, 127, 128, 129, 130, 131, 132, 133, 134, 135, 136, 137, 138, 139, 140, 141, 142, 143, 144, 145, 146, 147, 148, 149, 150, 151, 152, 153, 154, 155, 156, 157, 158, 159, 160, 161, 162, 163, 164, 165, 166, 167, 168, 169, 170, 171, 172, 173, 174, 175, 176, 177, 178, 179, 180, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190, 191, 192, 193, 194, 195, 196, 197, 198, 199, 200, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220, 221, 222, 223, 224, 225, 226, 227, 228, 229, 230, 231, 232, 233, 234, 235, 236, 237, 238, 239, 240, 241, 242, 243, 244, 245, 246, 247, 248, 249, 250, 251, 252, 253, 254, 255, 256, 257, 258, 259, 260, 261, 262, 263, 264, 265, 266, 267, 268, 269, 270, 271, 272, 273, 274, 275, 276, 277, 278, 279, 280, 281, 282, 283, 284, 285, 286, 287, 288, 289, 290, 291, 292, 293, 294, 295, 296, 297, 298, 299, 300, 301, 302, 303, 304, 305, 306, 307, 308, 309, 310, 311, 312, 313, 314, 315, 316, 317, 318, 319, 320, 321, 322, 323, 324, 325, 326, 327, 328, 329, 330, 331, 332, 333, 334, 335, 336, 337, 338, 339, 340, 341, 342, 343, 344, 345, 346, 347, 348, 349, 350, 351, 352, 353, 354, 355, 356, 357, 358, 359, 360, 361, 362, 363, 364, 365, 366, 367, 368, 369, 370, 371, 372, 373, 374.
These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information
Sample conditions:
- 3 samples in Discrepancy w/ COC condition. (#11, #12, #13)
- 371 samples in Good condition.
10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | LabReports@SanAir.com
23958Project Number:
P.O. Number:
Project Name: CCISD Fannin Elementary
5/25/2026Collected Date:
5/28/2026 10:15:00 AMReceived Date:
6/2/2026 5:13:14 PM
26031190 SanAir ID Number
FINAL REPORT
SITEX Inc.Name:
Address: 1525 S. Broadway
St. Louis, MO 63104
713-782-4411Phone:
Analyst: Tallert, Jonathan | O'Connell, Christopher | Williams, Darien | Mayes, Jean | Dunville, Reece | Parker, Sarah | Magalis, Lane | Armitage, Morgan | Hogrefe, Sarah | Moore, Brandi | Campbell, Grace
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 1 / 26031190-001 Floor Tile 12x12 W/ Streaks Rooms 1-5, 7, 8 Room 2
White Non-Fibrous
Homogeneous
100% Other None Detected
2 / 26031190-002 Floor Tile 12x12 W/ Streaks Rooms 1-5, 7, 8 Room 3
White Non-Fibrous
Homogeneous
100% Other None Detected
3 / 26031190-003 Floor Tile 12x12 W/ Streaks Rooms 1-5, 7, 8 Room 4
White Non-Fibrous
Homogeneous
100% Other None Detected
4 / 26031190-004 Floor Tile 12x12 W/ Streaks Rooms 1-5, 7, 8 Room 6
White Non-Fibrous
Homogeneous
100% Other None Detected
5 / 26031190-005 Floor Tile 12x12 W/ Streaks Rooms 1-5, 7, 8 Room 7
White Non-Fibrous
Homogeneous
100% Other None Detected
6 / 26031190-006 Floor Tile Mastic Rooms 1-5, 7, 8 Room 2, Mastic/Leveler
Various Non-Fibrous
Heterogeneous
100% Other None Detected
7 / 26031190-007 Floor Tile Mastic Rooms 1-5, 7, 8 Room 3
Yellow Non-Fibrous
Homogeneous
100% Other None Detected
8 / 26031190-008 Floor Tile Mastic Rooms 1-5, 7, 8 Room 4
Yellow Non-Fibrous
Homogeneous
100% Other None Detected
9 / 26031190-009 Floor Tile Mastic Rooms 1-5, 7, 8 Room 6
Yellow Non-Fibrous
Homogeneous
100% Other None Detected
10 / 26031190-010 Floor Tile Mastic Rooms 1-5, 7, 8 Room 7, Mastic/Leveler
Various Non-Fibrous
Heterogeneous
100% Other None Detected
Analyst:
Analysis Date: 6/2/2026 Date: 6/2/2026
Approved Signatory:
10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | LabReports@SanAir.com
23958Project Number:
P.O. Number:
Project Name: CCISD Fannin Elementary
5/25/2026Collected Date:
5/28/2026 10:15:00 AMReceived Date:
6/2/2026 5:13:14 PM
26031190 SanAir ID Number
FINAL REPORT
SITEX Inc.Name:
Address: 1525 S. Broadway
St. Louis, MO 63104
Analyst: Tallert, Jonathan | O'Connell, Christopher | Williams, Darien | Mayes, Jean | Dunville, Reece | Parker, Sarah | Magalis, Lane
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 11 / 26031190-011 Sheet Vinyl Material Rooms 1-16 Room 3
Green Non-Fibrous
Homogeneous
100% Other None Detected
12 / 26031190-012 Sheet Vinyl Material Rooms 1-16 Room 6
Green Non-Fibrous
Homogeneous
100% Other None Detected
13 / 26031190-013 Sheet Vinyl Material Rooms 1-16 Room 10
Green Non-Fibrous
Homogeneous
100% Other None Detected
14 / 26031190-014 Sheet Vinyl Mastic Mastic Rooms 1-16 Room 3
Yellow Non-Fibrous
Homogeneous
100% Other None Detected
15 / 26031190-015 Sheet Vinyl Mastic Mastic Rooms 1-16 Room 6, Mastic/Leveler
Various Non-Fibrous
Heterogeneous
100% Other None Detected
16 / 26031190-016 Sheet Vinyl Mastic Mastic Rooms 1-16 Room 10, Mastic/Leveler
Various Non-Fibrous
Heterogeneous
100% Other None Detected
17 / 26031190-017 Sink Mastic Mastic Rooms 1-16 (16 Sinks) Room 3
Black Non-Fibrous
Homogeneous
100% Other < 1% Chrysotile
18 / 26031190-018 Sink Mastic Mastic Rooms 1-16 (16 Sinks) Room 6
Black Non-Fibrous
Homogeneous
100% Other < 1% Chrysotile
19 / 26031190-019 Sink Mastic Mastic Rooms 1-16 (16 Sinks) Room 14
Black Non-Fibrous
Homogeneous
100% Other < 1% Chrysotile
20 / 26031190-020 Pipe Insulation Mastic Mastic Inside Building Below Rooftop
White Fibrous
Homogeneous
98% Other 2% Chrysotile
Analyst:
Analysis Date: 6/2/2026 Date: 6/2/2026
Approved Signatory:
10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | LabReports@SanAir.com
23958Project Number:
P.O. Number:
Project Name: CCISD Fannin Elementary
5/25/2026Collected Date:
5/28/2026 10:15:00 AMReceived Date:
6/2/2026 5:13:14 PM
26031190 SanAir ID Number
FINAL REPORT
SITEX Inc.Name:
Address: 1525 S. Broadway
St. Louis, MO 63104
Analyst: Tallert, Jonathan | O'Connell, Christopher | Williams, Darien | Mayes, Jean | Dunville, Reece | Parker, Sarah | Magalis, Lane
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 21 / 26031190-021 Drywall Powder W/ Fiber Rooms 1 -16, Restrooms Room 3
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
22 / 26031190-022 Drywall Powder W/ Fiber Rooms 1 -16, Restrooms Room 6
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
23 / 26031190-023 Drywall Powder W/ Fiber Rooms 1 -16, Restrooms Room 10
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
24 / 26031190-024 Drywall Powder W/ Fiber Rooms 1 -16, Restrooms Room 11
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
25 / 26031190-025 Drywall Powder W/ Fiber Rooms 1 -16, Restrooms Room 14
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
26 / 26031190-026 Joint Compound Powder Rooms 1 -16, Restrooms Room 3
White Non-Fibrous
Homogeneous
100% Other None Detected
27 / 26031190-027 Joint Compound Powder Rooms 1 -16, Restrooms Room 6
White Non-Fibrous
Homogeneous
100% Other None Detected
28 / 26031190-028 Joint Compound Powder Rooms 1 -16, Restrooms Room 10, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
28 / 26031190-028 Joint Compound Powder Rooms 1 -16, Restrooms Room 10, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
29 / 26031190-029 Joint Compound Powder Rooms 1 -16, Restrooms Room 11, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 6/2/2026 Date: 6/2/2026
Approved Signatory:
10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | LabReports@SanAir.com
23958Project Number:
P.O. Number:
Project Name: CCISD Fannin Elementary
5/25/2026Collected Date:
5/28/2026 10:15:00 AMReceived Date:
6/2/2026 5:13:14 PM
26031190 SanAir ID Number
FINAL REPORT
SITEX Inc.Name:
Address: 1525 S. Broadway
St. Louis, MO 63104
Analyst: Tallert, Jonathan | O'Connell, Christopher | Williams, Darien | Mayes, Jean | Dunville, Reece | Parker, Sarah | Magalis, Lane
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 29 / 26031190-029 Joint Compound Powder Rooms 1 -16, Restrooms Room 11, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
30 / 26031190-030 Joint Compound Powder Rooms 1 -16, Restrooms Room 14
White Non-Fibrous
Homogeneous
100% Other None Detected
31 / 26031190-031 Floor Tile 12x12 W/ Streaks Hallways Of Rooms 1-16 And Rooms
Cream Non-Fibrous
Homogeneous
100% Other None Detected
32 / 26031190-032 Floor Tile 12x12 W/ Streaks Hallways Of Rooms 1-16 And Rooms
Cream Non-Fibrous
Homogeneous
100% Other None Detected
33 / 26031190-033 Floor Tile 12x12 W/ Streaks Hallways Of Rooms 1-16 And Rooms
Cream Non-Fibrous
Homogeneous
100% Other None Detected
34 / 26031190-034 Floor Tile 12x12 W/ Streaks Hallways Of Rooms 1-16 And Rooms
Cream Non-Fibrous
Homogeneous
100% Other None Detected
35 / 26031190-035 Floor Tile 12x12 W/ Streaks Hallways Of Rooms 1-16 And Rooms
Cream Non-Fibrous
Homogeneous
100% Other None Detected
36 / 26031190-036 Floor Tile Mastic Mastic Hallways Of Rooms 1-16 And Rooms 13
Various Non-Fibrous
Homogeneous
100% Other None Detected
37 / 26031190-037 Floor Tile Mastic Mastic Hallways Of Rooms 1-16 And Rooms 13
Various Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 6/2/2026 Date: 6/2/2026
Approved Signatory:
10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | LabReports@SanAir.com
23958Project Number:
P.O. Number:
Project Name: CCISD Fannin Elementary
5/25/20…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .