Addendum #2 - 2024-11-07 - BCCCH IFB#24-24813.pdf
PDF 29 MB Posted
- Solicitation number
- 80096
- Issued by
- Botetourt County, Virginia
About this file
This document is Addendum #2 related to IFB 24-24813 for the construction of the Botetourt County Courthouse in Virginia. The solicitation is for pre-qualified general contractors to bid on the project. A mandatory pre-bid meeting was held on October 24, 2024 at the courthouse location. The project consists of the construction of the Botetourt County Courthouse. Bids will not be accepted from subcontractors. The solicitation includes a due date, but the specific deadline is not provided in the addendum.
The addendum does not provide details on pricing terms, set asides, incumbents, funding requirements, or other salient financial information. It focuses on clarifying and amending the original solicitation documents.
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ad d e n d u m
10 9th S treet , Lynchburg , Vi rginia 24504 p 434-846-8456 | f 434-846-4534 | www.archi tecturalpar tners.com
Botetourt County New Circuit Courthouse
DATE: 11/7/2024
TO: All Bid Document Holders
FROM: Gary E Harvey
COMM. #: 24131
ADDENDUM #: 2
BID DATE*: 11/26/2024
*See QUESTIONS/ANSWERS AND CLARIFICATIONS #1
BID TIME: 2:00pm
BID LOCATION: Purchasing Office, Rm. 200, at 57 S. Center Drive, Daleville, VA 24083, Atten: Stephanie Sparks - purchasing@botetourtva.gov
This addendum becomes part of the Construction Documents. The following changes, additions, and deletions shall be made to the following documents; all other conditions shall remain the same. Please attach to all copies of the Construction Documents which you are holding.
All Contractors are to state in their bid the receipt of this addendum.
Instruction to Bidders:
ADDENDUM TO THE DRAWINGS:
Number Drawing Detail No.
AD2.1 C-102 n/a Illustrated extents of backfill to be removed behind retaining wall ‘RW-EX’ and added note for clarification.
AD2.2 L100 &
L404
1 Clouded area of plan and added note to address contractor question. See QUESTIONS/ANSWERS AND CLARIFICATIONS
#3.
AD2.3 L401 1 Callout corrected from 3/504 to 4/505.
AD2.4 L402 1 Callout corrected from 10/502 to 10/500.
AD2.5 A1.04a 1 Added “SEE STRUCTURAL.” to note pertaining to grating.
http://www.architecturalpartners.com/
2 Deleted.
AD2.6 A1.05.a 1 Showed downspout locations routed from metal roof areas to basement. Changed wall type for a portion of wall at ‘Clerk Waiting 103A’.
AD2.7 A1.06.a 1 Showed downspout locations routed from metal roof areas to basement. Added callouts for ‘3A1.43’. Adjusted dimensions in ‘Hearing Courtroom 213’.
AD2.8 A1.08.a 1 Illustrated downspout locations near portico.
AD2.9 A1.11 1 Added callout plan reference ‘4/A1.12’.
2 Revised ‘Public Corr. 201’ ceiling tag from ‘ACT-1’ to ‘ACT- 4’. Removed bulkhead at ‘W. Toilet 205’. Revised height of ceiling tag ‘2101’ from 27’-6” to 27’-3”.
n/a Added general reference note stating “SEE SHEET A1.13
FOR TYPICAL BULKHEAD AND CEILING TRANSITION
DETAILS.“
AD2.10 A1.12 1 & 2 Showed section reference ‘1/A1.13’. Added dimension references for bulkhead locations.
3 Adjusted view crop to show bulkhead sections ‘12/A1.13’.
Illustrated bulkheads in ‘Jury Assembly’. Revised ceiling elevation tags in ‘Lobby’ to reference finish floor of the ‘Lobby’, changing from 13’-6” to 25’-6”.
4 Added callout reflected ceiling plan.
AD2.11 A1.13 13 Illustrated taller vertical insulation.
AD2.12 A1.40a- A1.42
ALL For clarity: revised inconsistent hatch patterns, rotated details to align with plan North, and deleted unused details.
AD2.13 A1.43 1, 3, & 4 Added dashed downspout above for increased clarity.
AD2.14 A3.10 9 & 11 Illustrated header framing at base of bulkhead in section detail #9 and added enlarged section detail #11.
AD2.15 A3.11a 3 & 11 Clarified standard riser/nosing profile by replacing detail #3 and deleting detail #11.
AD2.16 A4.02 1 Included downspout piping from upper roof.
AD2.17 A5.10 2, 3, 4, 5, 6,
7, & 8
Revised trim profiles and notes to match the correct profiles from ‘A1.25’ and ‘A6.02b’.
AD2.18 A5.11 3 Callout waterproofing on the exterior face of the foundation wall.
AD2.19 A5.12 1, 2, 3, 4, 5,
6, 7, 8, 10, &
Revised trim profiles and notes to match the correct profiles from ‘A6.02b’.
AD2.20 A5.15 ALL Changed references as follows: “Bentonite” to “Bentonite Waterproofing Membrane”, “Membrane” to “Sheet Waterproofing Membrane”, “Approved Protection Course” to “Approved Protection/Drainage Sheet”, “Bentoseal” to “Bentonite Sealant”, “M-2000” to “Liquid Sealant”, and “Above Grade Air Barrier” to “Weather Barrier”. Changed titles of details.
NOTES Added note #2 stating, ”All sections of all subgrade building walls, regardless of wall assembly, are to be waterproofed in strict accordance with drawing details, specifications, and single-source manufacturer’s instructions for a complete and warrantied system.”
1 Removed gap between insulation and CMU. Changed text of note from ‘OTHERS’ to ‘CONTRACTOR’. Added note #2 stating “SIMILAR ASSEMBLY FOR CONCRETE WALL.”
7 Illustrated through wall metal drip edge flashing.
9 Deleted.
10 Removed excess components and references.
AD2.21 A6.01 DOOR
SCHEDULE
Changed all 1/A6.02b casings to ‘13/A6.02b’ and updated head and jamb details associated with these doors.
WINDOW
SCHEDULE
Revised window casing types.
AD2.22 A6.03 H5 & J5 Revised details to align more closely with existing vault frame and casing.
AD2.23 A6.04 H13, J13,
H18, J18
Revised casing and jamb profile references.
AD2.24 A6.05 H19, J19,
H20, J20
Changed referenced casing detail from ‘1/A6.02b’ to ‘13/A6.02b’.
AD2.25 A6.10 3 & 4 Revised hollow metal transom frame/door header to 6” hollow metal.
AD2.26 A7.20 ALL Changed detail names to include view direction. Updated casing profiles to be consistent with scheduled profiles.
Clarified window tags.
AD2.27 A7.20 5
AD2.28 S1.5 n/a Added further clarification and references to note regarding backfill work at retaining wall ‘RW-EX’.
AD2.29 S1.7 25 Removed second slab and illustrated full depth of turndown.
AD2.30 P2.01-
P2.04
ALL Illustrated downspout piping from two downspouts on the high roof area at attic to the storm line in the basement.
AD2.31 E2.02.a n/a Added note #10.
AD2.32 E2.04.a n/a Added note #9. Noted additional data at wall mounted televisions in witness rooms. Added additional WAP in ‘Jury Assembly’ and Witness 3’. Added receptacle and data for wall mounted television in ‘Hearing Courtroom’. Added power to motor operator in the other ‘Jury Courtroom’.
AD2.33 E2.04b n/a Revised rack layout in telecom area. Noted additional data ports in both courtrooms.
AD2.34 E3.05 EMP2 & P2 Revised circuits.
AD2.35 E3.06 P2A Revised circuits.
AD2.36 E4.07 N/A Revised rack layout in telecom area.
ADDENDUM TO THE SPECIFICATIONS:
Number Spec Section
AS2.1 01 1000 Included additional Owner supplied Contractor installed items.
AS2.2 07 4213 Revised to include both to FW-120 – Exterior Wall Panel and Artisan – Interior Liner Panel
AS2.3 09 5423 Added section covering exterior metal ceiling at portico.
AS2.4 12 2400 Clarified conflicts throughout specification in response to Contractor questions. See QUESTIONS/ANSWERS AND
CLARIFICATIONS #8-#13.
AS2.5 12 5000 Revised Section 2.01 to read “SEE ATTACHED
FURNITURE SPECIFICATIONS AND DATA FOR BASIS
OF DESIGN”.
AS2.6 26 0533 Revised Section 2.12(C).
AS2.7 28 1311.01 Added section covering card reader pedestal.
QUESTIONS/ANSWERS AND CLARIFICATIONS:
Number
1 Question We are requesting that the date for final questions be extended to November 12
Answer The last day for questions has been extended to Tuesday, November 12th and the bid date will be extended to Tuesday, November 26th.
2 Question Will the areas requiring the clean agent fire protection need to have a wet system back-up?
Answer No, the areas that are to be protected by clean-agent suppression are not to be protected with a wet system for back-up.
3 Question Please clarify the scope for all pavers that are to be mortar-set vs. all pavers that are to be sand-set.
a. Detail 2/L500 shows a metal edge restraint. Specification Section 32 1400, part 3.3 describes the edge pavers as being mortar-set.
b. ) L404 shows at least 3 notes stating the pavers are to be mortar-set. Are we to assume all pavers shown on this sheet are mortar-set? This refers only to full-height pavers.
Thin pavers are to be mortar-set. Correct?
Answer See attached revised drawing sheets L100 and L404 for clarification.
4 Question Where on the site is the temporary bell structure located?
Answer See sheet L402 (included with this addendum) for location information.
5 Question Please clarify the scope of the retaining wall backfill removal and replacement. Are we only removing and replacing portion or the entire length of the wall?
Answer See revised sheets C-102 and S1.5 (included with this addendum) for further information.
6 Question Sheet FP1.04 calls for the gabled attic space to be sprinkled. The structure is steel and the roof deck is metal. Thus being non-combustible construction this area does not require sprinklers per NFPA-13. Please confirm sprinklers will be required.
Answer Fire sprinkler coverage may be omitted in locations where coverage is not required by NFPA 13 as determined by the sprinkler contractor.
7 Question Will the cupola be required to be sprinkled?
Answer Fire sprinkler coverage may be omitted in locations where coverage is not required by NFPA 13 as determined by the sprinkler contractor.
8 Question No blackout fabric is listed in the specifications. Which blackout do we price?
Answer Shade fabric is to be ‘EcoVeil Screens – 1550 Series (3% open). Specification section ‘12 2400 – Window Shades – MechoShade Systems’ has been updated.
9 Question Specifications list both 120v EDU and 24v EDU. Which one is required?
Answer 120v EDU. Specification section ‘12 2400 – Window Shades – MechoShade Systems’ has been updated.
10 Question Specifications call for double roller shades but only list one fabric 1550 series 3%, the drawing on sheet A1.14 shows a single roller shade, in a 5"x 5" recessed ceiling pocket. Are these single or double roller shades? The pocket for a double shade is a lot bigger than 5" x 5”.
Answer The roller shades are to be single roller in a recessed ceiling pocket.
Specification section ‘12 2400 – Window Shades – MechoShade Systems’ has been updated.
11 Question Are motorized roller shades operated as a group, controlled by a single wall switch?
Answer Motorized roller shades are operated as a group controlled from a singular switch location. See note #1 on Sheet E2.04.a.
12 Question Are motorized shades connected to and controlled with a third party system?
Answer There is no third-party system planned for the integration and control of the motorized shades.
13 Question If roller shade system are single roller shades with solar fabric. Are side channels required?
Answer Side channels are not required. Specification section ‘12 2400 – Window Shades – MechoShade Systems’ has been updated.
ATTACHMENTS:
1) Specification sections as listed under ‘Addendum to the Specifications’
2) Drawing sheets as listed under ‘Addendum to the Drawings’
END OF ADDENDUM #2
U G
G U
G G
U G
G U
G G
U G
G U
G G
U G
G U
G G
U G
G
U G
G
UG UNK
UG UNK
UG U
NK
UG UNK
UG U
NK
U G
G
UG G
UG G
UG G
UG G
UG G
UG G
UG G
UG G UG G UG G UG G UG G
UG G UG G
UG
G
U G
G
UG G
UG G
UG G
UG G
UG G
X
X
X
U G
T U
G T
U G
T
UG FO
UG
CTV
W W
W W
W
W
W W
W
WV
FP
U G
U N
K
U G
U N
K U
G U
N K
U G
U N
K U
G U
N K
EOI
EO
I
G
G
U G
E
UG E UG E
UG E
U G
E U
G E
UG EUG E
UG E
UG E
U G
E
UG E
U G
E
E o o o o o o o o o
X X
X
XXXX
X X
X
X
X
HVHV
UG FO
HV
G
HV
HV
HV HV E
EOI
HV
HV
E
EOI
W
E
HV
HV
HV
HVHV
E
W
GV
G V
6" SS
6" SS
6" S
S
6" S
S
6" S
S
6" SS
6" SS
WV
S
S
FF =1251.61'
2-ST BRICK
BUILDING
"MUSEUM"
FF =1261.5'
2ND FLOOR
FF =1243.15'
FF =1246.9'
FF =1257.3'
FF =1257.3'
FF =1257.3'
3-ST BRICK BUILDING
FF =1246.85'
3-ST BRICK
BUILDING
"OLD JAIL"
FF =1256.85'
2ND FLOORFF =1238.64'
FF =1227.58'
GARAGE
15" CMP - RCP
(APPEARS TO
CHANGE UG)
INV IN =1226.7'
INV OUT =1220.2'
DROP INLET
TOP =1209.8'
INV OUT =1207.6'
SIGN
SIGN
SI
G
N
SIGN SIGN
SIGN
SI
G
N
SIGN
MONUMENTS
STONE WALL
STONE WALL
STONE WALL
ST
O
N E
W
AL
L
ST
ONE
W
AL
L
C O
N C
. W
AL
L
TI
M
BE
R
W
AL
L 2-ST BRICK
BUILDING
"OLD DISTRICT
COURT BUILDING"
FF =1254.82'
FF =1247.40
BASEMENT'
FF =1252.24'
G
EN
ER
AT
O R
FF =1225.46'
2ND FLOOR
FF =1214.74'
GARAGE
FF =1225.46'
2-ST FRAME
BUILDING
2-ST BRICK FRAME
BUILDING
TIMBER WALL
18" RCP W/ FLARED
END SECTION
INV IN =1204.9'
DROP INLET
TOP =1207.2'
INV IN =1204.9'
INV OUT =1204.8'
" R
C P
2-
ST
B R
IC
K
BU
IL
D
IN
G "V
PI
E
XT
EN
SI
O
N
FF
.2 1'
ASPHALT DITCH
ELEVATED W
OOD SIDEWALK
24" HICKORY
CREPE MYRTLE
LOCUST CLUSTER
15" PINE
15" PINE
10" PINE
22" PINE
12" PINE
24" PINE
24" PINE
12" PINE
14" MAPLE (2)
20" TREE
28" MAPLE 10" ORN
8" DOGWOOD
8" DOGWOOD
36" MAPLE
36" OAK
36" OAK
.1
.1
32.0'
DOUBLE CEDAR
16.2'
.4
.8
13.2'
43.7'
.4
12.3'
.1
.6
.2
2.2'
.7
28.1'
.0
8.
1'
0.7' 24.0'
15.4'
.6
5.1'
5.7' 5.4' 15.2' 3.9' 31.9'
43.5'
8.
0' 8.
1'
.0
' 36 .7
.0
.4
3.7'
.9
25.3'
4.
5'
4.
4' 40.3'
25.1'
.6
.0
1.9'
23.9'
.2
26.0'
0.7'
1.0' 1.0'
1.0' 1.0'
.9
37.3'
CENTERLINE OF PAVEMENT
CENTERLINE OF PAVEMENT
C
EN
TE
R
LI
N
E O
F
PA
VE
M
EN
T
CONCRETE DITCH
W. BACK STREET
ROUTE T-1205
S.
R
O
AN
O
KE
S
TR
EE
T
R O
U
TE
T -1
(3 3'
R /W
W. MAIN STREET
ROUTE T-630
BO
TE
TO
U
R T
R O
AD
U
S R
O U
TE
(V
AR
IA
BL
E
W
ID
TH
R
/W
6" R C
P
IN
V O
U T =1242.1'
6" TC
PIPE
IN
V O
U
T =1243.0' EXPOSED ROOF
DRAIN PIPES
.3
.9
43.9'
ST
O
N E
W
AL
L
1206.8' +
1207.1' +
1207.5' +
1207.6' +
1207.7' +
TW 1250.3'
BW 1246.6'
TW 1255.2'
BW 1250.9'
TW 1255.5'
BW 1252.0'
TW 1236.7'
BW 1232.5'
+1249.1'
+1246.4'
+1244.9'
CONTROL NAIL
N: 3708484.03 E: 11082806.81
ELEV: 1208.69
CONTROL NAIL
N: 3708346.58 E: 11083252.48
ELEV: 1241.19
CONTROL NAIL
N: 3708127.74 E: 11083228.78
ELEV: 1257.81
CONTROL NAIL
N: 3708444.48 E: 11083023.76
ELEV: 1245.35
AS
PH
AL
T
W
AL
KUG T
GAZEBO
SHED
WOOD PORCH
" R
C P
W
AT
ER
VA
U
LT
WINDOW
WELL
MONUMENT
MONUMENT
BRICK
RAMP (TYP)
PILLARS
EOI
EOI
+1225.2'
IPF
N87° 04' 20"E
298.42'
N 2°
5'
0"
W
9.
N87° 04' 20"E 149.95'
N 0°
8'
0"
E
6.
N49° 0 9' 31"E
33.78'
N79° 16' 42"E
100.80'
N59° 07' 56"W 40.88'
N85° 20' 40"W 82.01' S87° 04' 20"W
326.19'
S2 ° 5
5'
0" E
7.
BOTETOURT COUNTY
BOARD OF SUPERVISORS
PID: 73A(1)20&20A
BOTETOURT COUNTY
COURTHOUSE
PID: 73A(1)15-19
1257.81
1256.65
X
X X
X X
X X
G
ATE
16" C O
N C
. R
ET. W
ALL
1246.3'TW +
1248.3'TW +
1248.3'TW +
1246.3'TW +
.3'
TW +
.9'
TW +
+ 1
6.3
'TW
1246.3'TW +
1246.3'TW +
1244.3'TW +
+ 1244.8'G
1230.9' +
1228.7'G +
+ 1239.7'G
+ 1244.3'G
U G
G U
G G
U G
G
U G
G
SAWCUT
SAWCUT
UG E
UG E
U G
E
UG
E
U G
E U
G E
UG E
UG E
UG E
UG E
UG E
UG E
U G
E U
G E
UG E
NEW
TRANS.
U G
E
UG E
UG E
U G
E U
G E
UG E
UG E
U G
E U
G E
U G
E
EO
I
UG E
UG E
UG E
UG E
EO
I
UG FO
UG FO U
G
FO
U G
FO
U
G
FO
UG FO
UG T
UG T
U G
T U
G T
U G
T
UG FO UG FO
U G
FO
U G
FO
U
G
FO
U G
FO
UG CTV UG CTV
UG CTV
U G
C
TV
U G
C
TV
U G
C
TV
U G
U N
K U
G U
N K
UG
UNK
UG UNK
EOI
POSSIBLE UG
WATER
UG U
NK
UG UNK
UG U
NK
U G
U N
K
UG UNK
EOI UG T
UG E
W
W W
EOI
6" SS 6" SS 6" SS 6" SS
6" SS 6" SS S
S
S A
B
C (1)
(2)
(2)
(1)UNDERGROUND
SEWER SHOWN
APPROXIMATE PER
INSPECTION OF
SANITARY MANHOLES
6" PVC 6" PVC
6" C
I
6" CI
6" CI
CO
S S
S
SS
SS
SS
CO
CO
S
E
F
G
(1)
(2)
H
I J
K
8" P
VC
8" PVC
8" PVC
8" P
VC
8" PVC
8" PVC
6" SS
D
20' SETBACK
' S
ET
BA
C K
XX
X
X
X
X
X
X X
X X
X X
X SSF
SSF
SSF
SSF
SSF
SSF
X X X X
X X
SSF
SSF
SSF
IP
LIMITS OF
CONSTRUCTION (2.95AC)
LIMITS OF
CONSTRUCTION (2.95AC)
LIMITS OF
CONSTRUCTION (2.95AC)
LIMITS OF
CONSTRUCTION (2.95AC)
SSF
EXISTING BRICK
SIDEWALK TO REMAIN
EXISTING BRICK
SIDEWALK TO BE
REMOVED AS SHOWN
EXISTING BRICK
SIDEWALK TO BE
REMOVED AS SHOWN
REMOVE
EXISTING
MANHOLES
REMOVE
EXISTING
SANITARY
EXISTING
PAVING/GUARDRAIL
TO BE REMOVED
CAP EXISTING
6" SANITARY SEWER
ABANDON EXISTING
SANITARY SEWER
SAWCUT AND REMOVED
EXISTING CONCRETE DITCH
AS NEEDED TO INSTALL NEW
ENTRANCE CULVERT PIPE
CONTRACTOR TO REMOVE
EXISTING UNDERGROUND
ELECTRIC
TP
X
X
TP
X
X
TP
X
X
TP
X
X
REMOVE
EXISTING
SANITARY
EXISTING
MANHOLE
TO REMAIN
EXISTING
MANHOLES
TO REMAIN
SAWCUT AND REMOVE
EXISTING ASPHALT AS SHOWN
SAWCUT AND REMOVE
EXISTING ASPHALT AS SHOWN
SAWCUT AND REMOVE
EXISTING ASPHALT AS SHOWN
SAWCUT AND REMOVE
EXISTING WALL AS SHOWN
COMMUNITY
CENTER
DODD BLD/OLD
PUBLIC WORKS
ALL EXISTING PAVEMENT TO BE SAWCUT SHALL
BE CUT TO A MINIMUM WIDTH OF 1' AND TO THE
FULL DEPTH OF THE EXISTING PAVEMENT (TYP)
SAWCUT AND REMOVE
EXISTING ASPHALT AS SHOWN
SAWCUT AND REMOVE
EXISTING ASPHALT AS
SHOWN
SAWCUT AND REMOVE
EXISTING ASPHALT AS SHOWN
SAWCUT AND REMOVE
EXISTING ASPHALT AS SHOWN
SAWCUT AND REMOVE
EXISTING ASPHALT AS SHOWN
10 7 10 76
10 7
10 7
2 31 5 84
REMOVE EXISTING WATER METER
AS SHOWN AND ABANDON LATERAL
AT THE WATER MAIN
ABANDON EXISTING LATERAL
AT THE WATER MAIN
REMOVE
EXISTING STAIRS
AS SHOWN
RELOCATE
EXISTING
HVAC UNIT
SALVAGE EXISTING
MECHANICAL
UNITS FOR RE-USE
(SEE LOH A1.1)
REMOVE EXISTING
FOUNDATION
FOLLOWING
REMOVAL OF
BUILDING. FILL
AND REGRADE
WITH CLEAN SOIL.
SAWCUT AND REMOVE
EXISTING ASPHALT
AS SHOWN
RELOCATE 3 PHASE AND
SINGLE PHASE ELECTRIC
(SEE UTILITY SHEET C-105)
RELOCATE
COMMUNICATION
LINES (SEE
UTILITY SHEET C-105)
PUBLIC PARKING
AND ACCESS TO
REMAIN UNTIL
UPPER PARKING LOT
IS OPEN
REMOVE
EXISTING
SANITARY
REMOVE AND STORE
EXISTING FENCE
AND GATE/RE-INSTALL
AFTER LAW OFFICE MOVE
AND STORM SEWER
INSTALLATION
PERMANENTLY REMOVE
AFTER WALL PEDESTRIAN
GUARDS INSTALLED
REMOVE POLE AND BASE
REUSE POLE AT RELOCATED
LOCATION IF NEEDED
EXISTING
SANITARY
TO REMAIN
EXISTING
SANITARY
TO REMAIN
EXISTING
SANITARY
TO REMAIN
EXISTING
SANITARY
TO REMAIN
CO
1.1
24.72'
17.82' 8.75'
9.06'
12.22'12.50'
8.
S
CE
THROUGHOUT HATCHED AREA, REMOVE ALL EXISTING BACKFILL INSTALLED BEHIND
RETAINING WALL (RW-EX) DOWN TO BOTTOM OF FOUNDATIONS. REMOVED BACKFILL
MATERIAL IS TO BE ASSUMED SUITABLE FOR PERMANENT PLACEMENT/REUSE AFTER IT IS
INSPECTED AND APPROVED FOR REUSE BY OWNER'S THIRD-PARTY INSPECTOR. INSTALL
NEW BACKFILL AS INDICATED PER STRUCTURAL. (SEE STRUCTURAL SHEET S1.5 FOR
FURTHER INFORMATION) EXCESS OR UNSUITABLE/SOIL CONTAMINATED STONE BACKFILL
(#57 STONE) MAY BE USED DURING THE CONSTRUCTION PROCESS TO CONSTRUCT
TEMPORARY PARKING AREAS OR TEMPORARY ACCESS ROADS.
10/18/2024
DATE:
DRAWN:
CHECKED:
NRO
PCP
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A
R C
H
IT
E C
T U
R A
L P
A R
T N
E R
S
P .C
LAT: 37.499228°
LONG: -79.878238°
ENGINEERING • SURVEYING • LAND DEVELOPMENT • ENVIRONMENTAL
GEOTECHNICAL • CONSTRUCTION TESTING & INSPECTION • CULTURAL RESOURCES
2524 LANGHORNE ROAD LYNCHBURG, VA. 24501
434.847.7796 HANDP.COM
INSPIRED / RESPONSIVE / TRUSTED
20200660
Lic. No. 034330
PATRICK C. PROFFITT
BID SET
10/18/2024
BO
TE
TO
UR
T
CO
UN
TY
N
EW
C
IR
C U
IT
C
O U
R
TH
O U
SE
W
ES
T M
AI
N
S T.
0, F
IN
C
AS
TL
E, V
A
P
R O
JE
C
T N
O .:2
SI
TE
SCALE 1" = 20'
0 10 20 40 C-102
DEMOLITION
AND STAGE 1
E&S PLAN
CE
SSF
IP
REFER TO SHEET C-002 FOR DEMOLITION NOTES
REFER TO SHEET C-002 FOR EROSION CONTROL NOTES
REFER TO SHEET C-505 FOR EROSION CONTROL DETAILS
DENOTES ITEM
TO BE REMOVED/DEMOLISHED
DENOTES ITEM
TO BE REMOVED/DEMOLISHED
LIMITS OF CONSTRUCTION
NEW LEGEND:
X
VIRGINIA UNIFORM CODING SYSTEM FOR EROSION
AND SEDIMENT CONTROL PRACTICES
* CHART TAKEN FROM THE VIRGINIA EROSION AND SEDIMENT
CONTROL HANDBOOK (JULY 1992)
TEMPORARY CONSTRUCTION ENTRANCE (3.02)
SUPER SILT FENCE (3.05)
STORM DRAIN INLET PROTECTION (3.07)
TP TREE PRESERVATION & PROTECTION (3.38)X
X
PRESERVATION OF HISTORIC MATERIALS
THE BOTETOURT COUNTY COURTHOUSE DESIGN CALLS FOR THE SALVAGE AND RE-USE
OF THE BOTETOURT COUNTY COURTHOUSE STONE WALLS AND FENCE MATERIALS.
THE FOLLOWING MATERIALS SHALL BE PRESERVED AND ARE TO BE REPURPOSED:
· IRON FENCE MATERIAL- INCLUDING PICKETS AND POSTS AND ASSOCIATED
HARDWARE
· IRON COLUMNS INCLUDING ALL ASSOCIATED HARDWARE
· IRON GATE WITH ARCHWAY INCLUDING ASSOCIATED HARDWARE.
· ALL CAP STONES FROM THE WALLS ADJACENT TO THE EXISTING COURTHOUSE.
· ALL STONE FROM THE WALLS ADJACENT TO THE EXISTING COURTHOUSE
THE CONTRACTOR SHALL SUPERVISE CAREFUL REMOVAL OF THE ABOVE MATERIALS IN
ORDER TO PRESERVE ALL COMPONENTS AND HARDWARE, REGARDLESS OF CONDITION
AT THE TIME OF REMOVAL. THE IRON FENCE SHALL BE DISASSEMBLED IN FULL PANEL
LENGTHS IN A CAREFUL MANNER MINIMIZING SAWCUTS AND AVOIDING DAMAGE. ALL
FASTENER COMPONENTS INCLUDING BROKEN OR RUSTED OUT COMPONENTS SHALL BE
PRESERVED AND MARKED WITH A UNIQUE IDENTIFIER SO THAT THEY CAN BE REUSED
OR EVALUATED FOR THEIR REPLACEMENT. NEW HARDWARE WILL BE REQUIRED TO
RE-ANCHOR THE RAILINGS, GATE, AND COLUMNS. NEW HARDWARE WILL NEED TO
MATCH EXISTING HARDWARE. THE GATE SHOULD BE REMOVED WITH AS LITTLE
DISASSEMBLY AS POSSIBLE, WHILE STILL RETAINING THE INTEGRITY OF THE UNIT. IF
ANY FENCE, GATE, OR COLUMN COMPONENTS ARE DAMAGED IN THE REMOVAL
PROCESS, THE CONTRACTOR WILL BE RESPONSIBLE FOR ANY REPAIR, WELDING, OR
RE-FINISHING IN ORDER TO ACHIEVE A PRODUCT EQUAL TO THE EXISTING CONDITION.
THE CONSTRUCTION MATERIALS SHALL BE STORED, STACKED, AND HANDLED IN SUCH
A MANNER TO PREVENT DETERIORATION, AND INTRUSION OF FOREIGN MATTER AND TO
ENSURE THE PRESERVATION OF THEIR QUALITY AND FITNESS FOR THE WORK. THE
MATERIALS SHALL BE SEGREGATED AS PER THEIR TYPE, SIZE, AND LENGTH, AND
PLACED IN NEAT, ORDERLY PILES THAT ARE SAFE AGAINST FALLING. IF THE PILES ARE
HIGH, THEY SHALL BE STACKED AT SUITABLE INTERVALS IN HEIGHT, AND A
PASSAGEWAY OF 3 FT WIDTH IS PREFERRED IN BETWEEN THE PILES OR STACKS FOR
INSPECTION OR REMOVAL. THE CONSTRUCTION MATERIALS SHALL BE STACKED ON
WELL-DRAINED, FIRM, AND UNYIELDING SURFACE AND SHALL NOT BE STACKED TO
IMPOSE ANY UNDUE STRESSES ON WALLS OR OTHER STRUCTURES.
UPON COMPLETION OF THE MATERIAL STOCKPILE, THE ARCHITECT AND CONTRACTOR
WILL WORK TOGETHER TO SELECT THE MATERIALS TO BE REPURPOSED FOR
CONSTRUCTION. ONCE SELECTIONS HAVE BEEN MADE, MATERIALS MARKED FOR
REJECTION MAY BE DISPOSED OF AND MATERIALS MARKED FOR PRESERVATION SHALL
BE STAGED FOR THEIR REUSE.
CONTRACTOR SEE NOTE AT TOP OF PAGE FOR
PRESERVATION OF HISTORIC MATERIALS
BEFORE STARTING DEMOLITION ACTIVITIES.
CONTRACTOR TO REFERENCE PROJECT
MANUAL FOR SALVAGE ITEMS LIST.#
SOME UTILITIES SHOWN ON SITE MAY NO LONGER BE
IN SERVICE. CONTRACTOR TO VERIFY AND CONFIRM
WITH THE RESPECTIVE UTILITY PROVIDERS THAT THE
EXISTING UTILITIES ARE ENERGIZED AND IN SERVICE.
REVISIONS:
NO. 2 ADDENDUM 2 11/07/24
11/07/2024
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
NORTH
CDF
D
YH
W
W V
DYH
10+37 10+00
CO
W V
CO
1.1
S
G
EN
ER
AT
O R
CENTERLINE OF PAVEMENT
CENTERLINE OF PAVEMENT
C
EN
TE
R
LI
N
E O
F
PA
VE
M
EN
T
CONCRETE DITCH
W. BACK STREET
ROUTE T-1205
S.
R
O
AN
O
KE
S
TR
EE
T
R O
U
TE
T -1
(3 3'
R /W
W. MAIN STREET
ROUTE T-630
BO
TE
TO
U
R T
R O
AD
U
S R
O U
TE
(V
AR
IA
BL
E
W
ID
TH
R
/W
X
X X
X X
X X
NEW
TRANS.
W W
EOI
Lower Parking Area L403
North Parking Area L401
Town Green L402
Front Courthouse L400
Town Green
Lawn
Lawn
Brick
C on cr et e
S id ew al k
Concrete
Brick
Brick
"SOUTH STREET
PARKING AREA"
"NORTH SECURE
PARKING AREA"
"UPPER
PARKING
AREA"
"LOWER
PARKING
AREA"
Conc.
L404
"LAW OFFICE
GROUNDS"
Law Office Grounds
DATE: 10/18/2024
DRAWN:
CHECKED:
BJS
JM
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A
R C
H
IT
E C
T U
R A
L P
A R
T N
E R
S
P .C
LAT: 37.499228°
LONG: -79.878238°
BID SET
B O
TE
TO
U R
T C
O U
N
TY
NE
W
C
IR
CU
IT
C
OU
RT
HO
US
E
SI
TE
W
ES
T
M
AI
N S
T.
0, F
IN
C
AS
TL
E, V A
O
JE
C T
N O
.:2
10-18-2024
L100
LANDSCAPE
IMPROVEMENTS
AND LAYOUT
Site Improvements Plan L100
Scale: 1" = 20' - 0" 0' 20' 40'
10'
GENERAL NOTES:
ALL DISTURBED ARES SHALL BE SEEDED. SEE
LP SHEETS FOR ALL TURF AND SEEDED AREAS.
Addendum #2: All bricks within the clouded area are thin bricks that are set in mortar (with a mortared edge, as per detail1/L501). Brick pavers outside the clouded area shown on sheets L 401 to L-403 are full-depth bricks that are sand-set with a metal edge restraint, as per detail 2/L500)
D
YH
CO
OH T
G
EN
ER
AT
O R
CENTERLINE OF PAVEMENT
W. BACK STREET
ROUTE T-1205
X X
X X
X X
X
X X X
NEW
TRANS.
L502
Perimeter Wall
RW-10
L502
Perimeter Wall
RW-6
Gate: See Architectural sheets
L500
Concrete steps with railing
L500
Railing
Step in wall height typ. Step in wall height typ.
O rnam ental/ sm all tree
LP500
8River cobble edge
Botetourt County Courthouse Building
5'
4'
6'
16'-8"
104°
13'-4"
90°
105'
65'-11"
R16'-5"Light typ. See Electrical sheets
Intercom Stanchion.
See Security Plan TS1.1
R23'-8"
156°
16'-11"
90°
3'-3"
156°
R28'
20'-3"
4'
5'
21' 5'-2"
6'
20'-10" 6'-3" 16'
5'
Step in wall height typ.
L505
"NORTH
SECURE
PARKING
AREA""UPPER
PARKING
AREA"44'-4"
89°
Wall steps down
Wall Step
Light typ. See electrical sheets
Expansion joint, typ.
See structural sheets for ramp details
L500
Handicap parking sign See Civil sheets
Concrete sidewalk:
See civil sheets
Light, typ. See Electrical sheets
Light, typ. See Electrical sheets
Ex. concrete
Ex. tree to remain
Intercom Stanchion.
See electrical sheets
L505
L505
Gen.
Trans.
6'
L500
Concrete steps with railing
DATE: 10/18/2024
DRAWN:
CHECKED:
BJS
JM
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A
R C
H
IT
E C
T U
R A
L P
A R
T N
E R
S
P .C
LAT: 37.499228°
LONG: -79.878238°
BID SET
B O
TE
TO
U R
T C
O U
N
TY
NE
W
C
IR
CU
IT
C
OU
RT
HO
US
E
SI
TE
W
ES
T
M
AI
N S
T.
0, F
IN
C
AS
TL
E, V A
O
JE
C T
N O
.:2
10-18-2024
L401
SITE
IMPROVEMENTS
& LAYOUT-
NORTH
SECURE
PARKING AREA
Site Improvements Plan- North Parking Area L401
M at ch lin e se e sh ee t L
Scale: 1" = 10' - 0" 0' 10' 20'
5'
Matchline see sheet L404
Addendum #2: Callout corrected from 3/504 to 4/5052
C D F
D Y H
10+37 10+00
GENERATOR
C
EN
TE
R
LI
N
E O
F
PA
VE
M
EN
T W
. M
AI
N S
TR
EE
T R
O U
TE
T
-6
X
Brick paver on concrete base
Brick paver on concrete base
Perimeter wall- RW-6
Town green seatwall
RW-4.2
Stacked stone wall
RW-5.1
Stacked stone wall
RW-5.2
L502
L502
L500
L502
L502
L500
Stage area for eventsL500
Bench
Light post with outlet- See Electrical sheets
Botetourt County Courthouse Building Gate
Trash receptacle L500
4'-10" 7'-10" 6'-4"
6'
24'
5'-9"
11'-9"
Stone wall with cast stone cap
RW-4.1
L502
6'-9"
6'-8"
3'-3"
19'-6"
10'
6'
52'-6"
16'-10"
72'-10"
3'-1"
4'-11"
Step in wall height
Step in wall height
Stone wall with cast stone cap
RW-4.1
L502
Existng wall to remain
Light typ. See Electrical sheets.
Match existing grade
3'-3"
21'-6"
30'-1"
4'-8"
1'-6" 1'-6"
Concrete entrance ramp
Yard Hydrant typ.LP500
Grasspave2 LP500
Town Green
Lawn
Concrete
Brick
Existing walkway to remain
Existing walkways to remain
Relocated historic mill stone
4'
Conc.
"LAW
OFFICE
GROUNDS"
Bell shelter- See Architectural sheets
L500
Ex. sign
+252.10 +250.60 +249.10
Lights- See Electrical sheets
9'
9'Lights- See Electrical sheets
L505
Removeable bollardL501
BenchL500
L500
Repurposed RailingL502
6'
DATE: 10/18/2024
DRAWN:
CHECKED:
BJS
JM
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A
R C
H
IT
E C
T U
R A
L P
A R
T N
E R
S
P .C
LAT: 37.499228°
LONG: -79.878238°
BID SET
B O
TE
TO
U R
T C
O U
N
TY
NE
W
C
IR
CU
IT
C
OU
RT
HO
US
E
SI
TE
W
ES
T
M
AI
N S
T.
0, F
IN
C
AS
TL
E, V A
O
JE
C T
N O
.:2
10-18-2024
L402
SITE
IMPROVEMENTS
& LAYOUT-
TOWN GREEN
Site Improvements Plan- Town Green L402
Matchline see sheet L403
Matchline see sheet L400
Matchline see sheet L404
Scale: 1" = 10' - 0" 0' 10' 20'
5'
M at ch lin e se e sh ee t L
Addendum #2: Callout corrected from 10/502 to 10/5002
G
EN
ER
AT
O R
X
XXXX
X X
X X
X X
X X
X X
X X
X
Precast cap and veneer
Conc.
Stepping stone base L501
L501
Brick seatwall, see ARCH plans
Seatwall L501
Bollard light typ.
See MEP Plans
Interpretive sign L501
Relocated WWII rock memorial
Expansion joint, typ. L500
Mortared brick to concrete sidewalkL501
Herringbone patternL500
Concrete sidewalk- See Civil sheets
Mortared brick L501
Mortared brick patio L501
Safety fence
CL
L501
Lewis and Clark Memorial NOAA Disk relocated
L501
Columns for balcony (See architecture sheets)
G en er at or p ad
Chain Link Gate
L501
Herringbone pattern L500
Herringbone pattern L500
Herringbone patternL500
Mortared brick L501
Mortared brick
L501
Bullnose edge all exposed/ above grade edges of porches ramps and stairs
"LAW
OFFICE
GROUNDS"
L502
Running bondL500
Patio steps
Bench mounting
Running bondL500
4L500 1Expansion joint, typ.
Running bondL500
L500 4Herringbone pattern
L500 4Herringbone pattern
Railing L500
Stone wall with precast concrete cap
RW-5.1.B
L502
Lewis and Clark sign relocated
Ex. Safety fence (to be replaced after Law
Office Building relocation)
Segmental retaining wall L501
Relocated Obelisk and Canons:
See Structural sheets. Final dimension to match field measurements of monuments
Trash receptacle L500
5' 5'-6"
10'
1'-6"
10'
18'-6"
5'-2"
5'-6"
14'-1"
9'-8"
6'-9"
5'-2"
2'-8"
2'-8"
16'14'-1"
2'
2'
18'-10"6'
7'-6"
2'3'
3'
L501 9Patio steps
Railing L500
Note:
1. Remove and store ex. fence and gate/re-install after Law Office move and storm sewer installation. Permanently remove after wall pedestrian guards are installed.
2. See Structural / Architectural details for ramp and porch edge conditions.
River Cobble LP500
26'1'
18'-2"
Relocated Bicentennial marker
Light typ. See electrical sheets
R1'-6"
R2'4'
CL
DATE: 10/18/2024
DRAWN:
CHECKED:
BJS
JM
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A
R C
H
IT
E C
T U
R A
L P
A R
T N
E R
S
P .C
LAT: 37.499228°
LONG: -79.878238°
BID SET
B O
TE
TO
U R
T C
O U
N
TY
NE
W
C
IR
CU
IT
C
OU
RT
HO
US
E
SI
TE
W
ES
T
M
AI
N S
T.
0, F
IN
C
AS
TL
E, V A
O
JE
C T
N O
.:2
10-18-2024
L404
SITE
IMPROVEMENTS
& LAYOUT- LAW
OFFICE
GROUNDS
Site Improvements Plan L404
M at ch lin e se e sh ee t L
M at ch lin e se e sh ee t L
Matchline see sheet L401
Scale: 1" = 5' - 0" 0' 5' 10'
2.5'
Addendum #2: All bricks within the clouded area are thin bricks that are set in mortar (with a mortared edge, as per detail1/L501). Brick pavers outside the clouded area shown on sheets L 401 to L-403 are full-depth bricks that are sand-set with a metal edge restraint, as per detail 2/L500)
C
A3.02
A3.02
A4.03
A4.01
A4.03
A4.03
A4.02
A3.01
A3.01
6 7
3.1
3.1
8.9
8.9
4.3
4.3
1.2
1.2 4.5
4.5
5.6
5.6
1 2
1.7
1.7 3
6.9
6.9
J J
KK
HH
NN
LL
PP
M M
J.1 J.1
J.5J.5
H.6H.6
K.5 K.5
A4.02
A2.03
________________________ 1 A4.01
K.9K.9
A2.03
A6.20
CRAWL SPACE
MECHANICAL
/ELECT.
006.2
FLEX
I.
M.
CL.1
CL.2
006D
006A
006C
UP
0E1
006G006H
006F
A3.13
1ELEV.
E1 L-11
L-3
L-1
L-2
27' - 8" 43' - 8" 27' - 8"
/8
/8
/8
1/
1/
F2B F
/8
/8
1/
/8
8' - 6 3/4" 9' - 4 1/2" 63' - 6 7/8" 4' - 0"
4' - 0"
1'
1/
8' - 8 3/8" 7' - 2" 8' - 7 5/8" 6' - 11 1/2" 9' - 3 5/8" 29' - 1" 27' - 0 1/8"
F 3' - 0"
1' - 0"
/2
/8
/4
1/
SEE STRUCTURAL. COORDINATE THE
LOCATION OF THE ACCESS PANELS
AND PITS WITH THE SELECTED
DETENTION PLUMBING FIXTURE PRIOR
TO INSTALLATION
A1.40a
A1.40a 9_ ______
A1.40a
A1.40a
A1.40a
A1.40a
A1.40a
9 _ ______ A1.40a
A1.40a
11 _ ______ A1.40a
A1.40a
A1.40a
A1.40a
A1.40a
A5.15
F1A
F1A
F1A F1A F1A
F1A
F1A
F1A
2' - 8"
10' - 0"
A1.40a
A1.40b
A1.40b
A1.40b
A1.40b
2 1/4"
A1.40a
A1.40a
A1.40a
A1.40b
A1.40b
A1.40b
A1.40b
NOTES:
• ALL CMU OUTSIDE CORNERS TO BE BULLNOSE
BLOCK
• ANY WATERPROOFING TO ALL SUBGRADE WALLS
IN ACCORDANCE WITH ASSOCIATED SECTIONS,
DETAILS, AND SHEET A5.15 UNLESS NOTED
OTHERWISE.
• VERIFY DOOR JAMB CLEARANCE IN ACCORDANCE
WITH 7/A6.02b
• SEE 8/A6.02b FOR TYPICAL DOOR PLACEMENT
(UNLESS DIMENSIONED OTHERWISE ON PLAN)
• COVER OR SHEATH ALL INSTALLED FRAMING AND
PROVIDE PROTECTION SUCH THAT WATER
CANNOT INFILTRATE THE WALL CAVITY BELOW
ARCHITECT
C O M
MO
NW
EA
LTH OF VIRGIN
AIGARY E. HARVEY
Lic. No. 11908
DATE:
DESIGNED:
DRAWN:
CHECKED:
REVISIONS:
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A R
C H
IT
E
C T
U R
A L
P A
R T
N E
R S
P
.C
BO
TE
TO
UR
T
CO
UN
TY
N
EW
C
IR
C U
IT
C
O U
R
TH
O U
SE
W
ES
T M
AI
N
S T.
0, F
IN
C
AS
TL
E, V
A
O
JE
C
T N
O
/7
/2
5:
:1
PM
10/18/2024
JMT/BEG
KTG/BEG/JRW
GEH
BID SET
10/18/2024
A1.04.a
BASEMENT
FLOOR
ENLARGED-
PART A
C C
H
0 3' 12'6' 24'
3/16" = 1'-0"
TN PN
3/16" = 1'-0"A1.04.a
1 BASEMENT FLOOR ENLARGED PLAN- PART A
KEY PLAN
A1.04.a NOTES No. Note Text
303 CONCRETE SLAB- SEE STRUCTURAL
DRAWINGS
410 8" CMU - GROUT SOLID
No. Date 1 10/30/2024 2 11/7/2024
2 2
LC
C
U.C.
Refr.
A2.01
A3.02
A3.02
A4.03
A4.01
A4.03
A4.03
A4.02
A7.10
A7.31
A7.31
A7.32
A7.20
A4.01
A3.01
A3.01
A7.11
6 7
3.1
3.1
8.9
8.94
1.2
1.2 4.5
4.5
5.6
5.6
1 2
1.7
1.7 3
6.9
6.9
JJ
KK
HH
NN
LL
PP
M
M
J.1J.1
J.5J.5
H.6H.6
K.5K.5
A4.02
A2.03
A2.03
A7.31
A4.01
A7.11
A2.01
K.9K.9
A7.20
A6.10
A3.11b
A3.11b
A7.20
A6.02a
A2.03
A6.20
A6.20
PARALEGAL
OFFICE
MANAGER
ELECT.
ELEV.
E1
CLERK
OF
COURT
TLT.
LOBBY
102A
PUBLIC
SPACE
GENEALOGY
PRINT/
COPY
SECURITY
C.A.
WAITING
BOOK
KEEPER
CLERK
CLERK
STAIR
S01
LOBBY
ENTRY
CLERK
WAITING
103A
CORR.
TLT.
TLT.
JAN.
136A
146A
109A
103B
103A
137A
113A
CLERK
CORR.
VEST.
CORR.
CLERK
COUNTER
103B
RECEPTION
GENERAL
OFFICE
UP
W9
W1
W1W1 W1 W1
W1
W1
W1
W1
W8
W8
W8
W6
W3
145A
WORK
TABLES/
SUPPORT
W8
110A
VICTIM/
WITNESS
102A
143A
144A
141A
104A
101C101B
147A
DN
1201.1
101A
102C
102B
W1
W10
102D
G01A
DF
A1.1
A1.3
B1.1
B1.1
A1.1
B1.1
A1.1
A1.1
A1.1A1.1
A1.3
A1.3A1.2
A1.1
A1.2
A1.1
A1.1
A1.1
A1.1
A1.1
D
D1
D
A1.1
28' - 8" 39' - 5" 28' - 8"
1/
1/
6' - 9 1/2" 13' - 6" 8' - 4 1/2" 7' - 1" 9' - 0 1/2" 7' - 2" 9' - 0 1/2" 7' - 1" 8' - 4 1/2" 13' - 6" 6' - 9 1/2"
/8
7'
/8
/8
1/
1/
1/
1/
12' - 7 7/8"12' - 8 1/2"12' - 7 7/8"
7' - 7"
96' - 9"
/8
17' - 7" 10' - 7"
/4
11'
/8
/8
1'
1/
1"
7' - 3 1/2" 8' - 6 3/4"
/8
11'
/8
/8
/8
6' - 7" 5' - 1 5/8"
28' - 2" 39' - 5" 15' - 0" 14' - 2"
2' - 7 1/2" 3' - 11 3/8" 2' - 11 1/4" 8' - 4 3/8" 9' - 9 1/2"
29' - 2"
/8
/4
11'
/8
12' - 10" 36' - 0 7/8" 31' - 6 1/4" 16' - 3 7/8"
/8
6' - 9 1/2" 12' - 7 3/8" 16' - 8" 22' - 1 3/8" 9' - 4 7/8" 15' - 3 7/8"
8' - 6 1/2" 4' - 0 7/8" 8' - 0" 8' - 8"
7'
5' - 4 1/8" 6' - 4 1/2"
11' - 8 5/8" 14' - 8 1/8" 12' - 0 1/4"
11'
/8
/8
F11
W14
F13
F14
F26
F18
F19
A3.1
G1
A1.2
F15 A3.1A1.1
F12
F10
B1.1A1.1
A1.1 15' - 5 3/4"
16' - 1 5/8" 6' - 0" 9' - 4 5/8"
/8
9' - 6 7/8"
F16
3204 32043204 3204 3204 3204 3204
A1.43
A6.10
AO
AO
CR
CR
CR
CR
CR
A7.31
1/
1'
/4 "9
/8
1'
/4 "9
/8
1'
/4
/4
A7.30
A7.30
A7.30
A7.30
A7.30
A7.31
A7.31
G
G
G G
G
G
A1.3
G
/8
B1.1
A3.2
A3.2
1E1
A7.22 7a
A7.30
7' - 6" 7' - 6"
A1.43
A1.43
A1.43
A1.43
A1.43
A1.43
A1.43
A7.23
114A
A1.44
CL
102B
A1.44
2 _ ______ A1.44
A1.41a
A7.22 3a
A7.11
A1.05.a
A1.05.a
A2.03
D
811.2
A7.35
D1
A1.41a
A1.41a
A1.41a
A1.41a
A1.41a
A1.41b
718A 718A
718A
718A
718A
718A
SHADED AREA PLAN LEGEND
SMOKE PARTITION - NOT RATED
SMOKE PARTITION AFFECTED OR
CLEAN AGENT AREA
CLEAN AGENT / DRY CHEMICAL SEAL
NOTE:
ALL PENETRATIONS IN PERIMETER WALLS
THAT ARE TO CONTAIN A CLEAN-AGENT FIRE
SUPPRESSION SYSTEM SHALL BE PROPERLY
SEALED TO MAINTAIN THE INTEGRITY OF THE
CLEAN-AGENT FIRE SUPPRESSION SYSTEM.
PROPER SEALING SHALL BE IN ACCORDANCE
WITH THE MANUFACTURER’S SPECIFICATIONS
AND APPLICABLE BUILDING CODES.
1.2
K.9
401A
A3.1
1' - 0"
8.9 9
J.5
2' - 0"
1'
401A
NOTES:
• ALL CMU OUTSIDE CORNERS TO BE BULLNOSE
BLOCK
• VERIFY DOOR JAMB CLEARANCE IN ACCORDANCE
WITH 7/A6.02b
• SEE 8/A6.02b FOR TYPICAL DOOR PLACEMENT
(UNLESS DIMENSIONED OTHERWISE ON PLAN)
• COVER OR SHEATH ALL INSTALLED FRAMING AND
PROVIDE PROTECTION SUCH THAT WATER
CANNOT INFILTRATE THE WALL CAVITY BELOW
ARCHITECT
C O M
MO
NW
EA
LTH OF VIRGIN
AIGARY E. HARVEY
Lic. No. 11908
DATE:
DESIGNED:
DRAWN:
CHECKED:
REVISIONS:
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A R
C H
IT
E
C T
U R
A L
P A
R T
N E
R S
P
.C
BO
TE
TO
UR
T
CO
UN
TY
N
EW
C
IR
C U
IT
C
O U
R
TH
O U
SE
W
ES
T M
AI
N
S T.
0, F
IN
C
AS
TL
E, V
A
O
JE
C
T N
O
/7
/2
5:
:3
PM
10/18/2024
JMT/BEG
KTG/BEG/JRW
GEH
BID SET
10/18/2024
A1.05.a
FIRST FLOOR
ENLARGED-
PART A
C C
H
TN PN
3/16" = 1'-0"A1.05.a
1 FIRST FLOOR ENLARGED PLAN- PART A 0 3' 12'6' 24'
3/16" = 1'-0"
A1.05.a NOTES No. Note Text
401A BRICK VENEER - FLEMISH BOND W/
GRAPEVINE STRUCK JOINT
413 PRECAST STONE PLINTH CAP - SEE DETAILS
ON 1/A1.44
414 PRECAST STONE COLUMN BASE
507 3 5/8" MTL STUDS @ 16"O.C.
509 METAL HANDRAIL - SEE TYPICAL DETAILS ON
A3.11a
602 FRP COLUMN COVER - SEE PROFILE ON
2/A2.10 -SEE BASIS OF DESIGN COLOR
605 5/8" GYPSUM SHEATHING
701 BATT INSULATION - R-19
702 2" RIGID INSULATION - R-10
707 BATT INSULATION - R-13
901 5/8" GWB - IMPACT RESISTANT
1003 QUEUING RAIL
1004 METAL DETECTOR - MAGNETOMETER
1005 X-RAY SCANNING MACHINE
1201.1 COUNTERTOPS & CASEWORK
2301 HVAC EQUIPMENT - SEE HVAC DRAWINGS
2302 STAINLESS STEEL FLOOR REGISTER VENT -
SEE MECHANICAL DRAWINGS
3204 SEE LANDSCAPING DRAWINGS FOR DETAILS
KEY PLAN
1/2" = 1'-0"A1.05.a
2 ELECT. 127 SHAFT DETAIL
1/2" = 1'-0"A1.05.a
CLERK OF COURT 110
SHAFT DETAIL
No. Date 1 10/30/2024 2 11/7/2024
CR
A3.02
A3.02
A2.02
A4.03
A4.01
A4.03
A4.03
A7.10
A4.01
A3.01
A3.01
6 7
3.1
3.1
8.9
8.9
4.3 4.5
4.5
5.6
5.6
1 2
2 3
6.9
6.9
JJ
KK
HH
NN
LL
PP
M M
J.1J.1
J.5
H.6H.6
K.5 K.5
A4.02
A4.01
A7.11
A2.01
A7.01
K.9K.9
A7.20
A7.20
A7.01
OPEN TO
BELOW
M.
TOILET
W.
TOILET
COURT
WAITING/JURY
ASSEMBLY
ELECT.
HEARING
COURTROOM
ELEV.
E1
VENDING
DETAINEE
232.1
ATTORNEY
CONF.
WITNESS
WITNESS
WITNESS
PUBLIC
CORR.
214A 213A
232.1A
210A
212A
DN
W6
W6
W12
W1
W1
W1W1 W1W1
W1
W1
W6
W6
W6
202A
203A
211A
205A
VEST.
206A
209A
208A 207A
232.2ASECURE
TOILET
232.2
201A
201B
W9
W9
W9
W9
W9
W11
W2 W2
1'
/8
7'
/8
/4
/8
11'
/4
4' - 0" 7' - 3 1/2" 8' - 6 3/4" 8' - 3 3/4" 39' - 5" 9' - 7 3/8" 13' - 11 5/8" 5' - 7"
1/
/8
/2
/8
/8
/8
8' - 11" 4' - 10 1/2" 10' - 4 1/2"
/4
/8
1"
1'
1/
"9
/2
/8
/8
1'
/2
/8
/8
1'
1"
1'
/8
/8
7'
/8
/8
1' - 9 1/2" A1.1 A2
A2
A2
A2
D B1.1
B2
A1.1
B1.1
A1.1
D
A2
A2
6' - 7 5/8" 13' - 2 5/8" 10' - 2 3/4" 13' - 3 1/2" 9' - 9 1/4" 6' - 4 1/8" 14' - 3" 8' - 4" 13' - 8 1/8"
35' - 9 1/8" 1' - 6"
36' - 4 3/8" 10' - 1 3/4" 6' - 0 1/2"
1/
1/
/8
7'
/8
/8
1/
1/
1/
1/
6' - 9 1/2" 13' - 6" 8' - 4 1/2" 7' - 1" 25' - 3" 7' - 1" 8' - 4 1/2" 13' - 6" 6' - 9 1/2"
28' - 8" 39' - 5" 28' - 8"
96' - 9"
/8
/8
/2
D
D
A2
A2
A2G G G G
G
I
IA2
G1
A2
G1
A3.1
A1.42
A1.42
A1.43
CR
CR
CRA2
A2
B1.1
I
G1
811.2
811.2
811.2
2E1
A7.22 18a
A7.22
I
B2
A7.30
A2 I
I
D
/8
29' - 2"
28' - 2"
11'
/4
37' - 3 1/8"
A1.43
A1.42
A1.42
A1.42
A1.43
A1.43
W13W13
A1.42
A1.42
A7.02
1'
9" 2' - 0"
1'
A1.06.a
A1.06.a
A1.06.a
A1.06.a
D1
STAIR
S01
A1.06.a
A1.43
A1.43
A1.42
A1.42
A1.42
A1.42
A1.42
A1.42
718A
718A718A
718A
718A
718A
J.5
401A
A3.1
9"
1'
1.2
L
K.9
401A
1/
1' - 0"
8.9 9
J.5
1/
2' - 0"
401A
8.9 9
K
901 507
401A
506 505
2' - 8 3/8"
1'
1 7 /8
1/
1' - 9 1/2" 901
NOTES:
• ALL CMU OUTSIDE CORNERS TO BE BULLNOSE
BLOCK
• ALIGN CENTERLINE OF WINDOWS/OPENINGS AT
SECOND FLOOR LEVEL PERIMETER OF LOBBY
WITH THE DOORS/WINDOWS/OPENINGS OF THE
FIRST FLOOR BELOW.
• VERIFY DOOR JAMB CLEARANCE IN ACCORDANCE
WITH 7/A6.02b
• SEE 8/A6.02b FOR TYPICAL DOOR PLACEMENT
(UNLESS DIMENSIONED OTHERWISE ON PLAN)
• COVER OR SHEATH ALL INSTALLED FRAMING AND
PROVIDE PROTECTION SUCH THAT WATER
CANNOT INFILTRATE THE WALL CAVITY BELOW
ARCHITECT
C O M
MO
NW
EA
LTH OF VIRGIN
AIGARY E. HARVEY
Lic. No. 11908
DATE:
DESIGNED:
DRAWN:
CHECKED:
REVISIONS:
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A R
C H
IT
E
C T
U R
A L
P A
R T
N E
R S
P
.C
BO
TE
TO
UR
T
CO
UN
TY
N
EW
C
IR
C U
IT
C
O U
R
TH
O U
SE
W
ES
T M
AI
N
S T.
0, F
IN
C
AS
TL
E, V
A
O
JE
C
T N
O
/7
/2
5:
:2
PM
10/18/2024
JMT/BEG
KTG/BEG/JRW
GEH
BID SET
10/18/2024
A1.06.a
SECOND
FLOOR
ENLARGED-
PART A
C C
H
TN PN
3/16" = 1'-0"A1.06.a
1 SECOND FLOOR REFERENCE PLAN- PART A 0 3' 12'6' 24'
3/16" = 1'-0"
A1.06.a NOTES No. Note Text
401A BRICK VENEER - FLEMISH BOND W/
GRAPEVINE STRUCK JOINT
505 STEEL TUBE - SEE STRUCTURAL DRAWINGS
506 6" MTL STUDS @ 16"O.C.
507 3 5/8" MTL STUDS @ 16"O.C.
605 5/8" GYPSUM SHEATHING
701 BATT INSULATION - R-19
702 2" RIGID INSULATION - R-10
707 BATT INSULATION - R-13
811.2 ALUMINUM CLAD WOOD WINDOW WITH
(OBSCURE) PATTERNED GLASS. SEE
SPECIFICATION SECTION 08 8000.
901 5/8" GWB - IMPACT RESISTANT
911 7/8" FURRING CHANNEL
919 CERAMIC TILE WAINSCOT, 5'-0" AFF
1012 BOTETOURT COUNTY SEAL - VERIFY
LOCATION WITH ARCHITECT
KEY PLAN
1/2" = 1'-0"A1.06.a
PUBLIC CORR. 201 SHAFT
DETAIL
1/2" = 1'-0"A1.06.a
3 ELECT. 212 SHAFT DETAIL
1/2" = 1'-0"A1.06.a
4 WITNESS 1 208 SHAFT DETAIL
1/2" = 1'-0"A1.06.a
5 W. TOILET 205 SHAFT DETAIL
1/2" = 1'-0"A1.06.a
ATTORNEY CONF. SHAFT
DETAIL
No. Date 1 10/30/2024 2 11/7/2024
F F
F
W P
SP
SP
A3.02
A3.02
A2.02
A4.03
A4.01
A4.03
A4.03
A4.01
8.9
8.9
2.8
2.8
1.2
1.21
7.2
7.2
KK
NN
LL
H.6H.6
A4.02
A4.01
A2.03
A4.02
A1.09b
A1.09b
1/4" / 12" DN
1/4" / 12" DN
718A
718A
718A
722722
4 1/2" / 12"
4 1 /2"
/ 1 2"
4 1 /2"
/ 1 2"
4 1 /2"
/ 1 2"
4 1 /2"
/ 1 2"
4 1/2" / 12"
3' - 8"
ROOFING RIDGE
LINE
3' - 0"
4' - 8"
722722
A1.09b
A1.09b
4 1/2" / 12" 4 1/2" / 12"
1/8" / 12" DN1/4" / 12" DN
1/4
" D
N
1/8" / 12" DN 1/8" / 12" DN
1/4
" D
N
1/4" / 12" DN
A4.02
3/8
" D
N
1/4" / 12" DN
1 1 /8"
/ 1 2"
D N
1/4" / 12" DN
1/4
" D
N
1/4" / 12" DN
1/2
" D
N
A7.02
A5.14
WALKPATH AROUND
DUCTWORK
A7.35
718A 718A
718A
718A
718A
7/
" 718A
718A
ARCHITECT
C O M
MO
NW
EA
LTH OF VIRGIN
AIGARY E. HARVEY
Lic. No. 11908
DATE:
DESIGNED:
DRAWN:
CHECKED:
REVISIONS:
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A R
C H
IT
E
C T
U R
A L
P A
R T
N E
R S
P
.C
BO
TE
TO
UR
T
CO
UN
TY
N
EW
C
IR
C U
IT
C
O U
R
TH
O U
SE
W
ES
T M
AI
N
S T.
0, F
IN
C
AS
TL
E, V
A
O
JE
C
T N
O
/7
/2
5:
:5
PM
10/18/2024
JMT/BEG
KTG/BEG/JRW
GEH
BID SET
10/18/2024
A1.08.a
ROOF PLAN
ENLARGED-
PART A
C C
H
TN PN
3/16" = 1'-0"A1.08.a
1 ROOF ENLARGED PLAN- PART A 0 3' 12'6' 24'
3/16" = 1'-0"
A1.08.a NOTES No. Note Text
715 METAL ROOF
718A DOWNSPOUT
722 HIDDEN GUTTER SYSTEM - SEE 6/A1.09a
1008 WALK PAD
2202 ROOF DRAIN - SEE PLUMBING DRAWINGS
2602 FLOOD LIGHT - SEE ELECTRICAL DRAWINGS
KEY PLAN
No. Date
1 10/30/2024 2 11/7/2024
NOTE:
• COVER OR SHEATH ALL INSTALLED FRAMING AND
PROVIDE PROTECTION SUCH THAT WATER
CANNOT INFILTRATE THE WALL CAVITY BELOW
M M
M
W P
WP
M M
M M
M M
F
W P
W P
W P
M
C
ES
CR
ELEV.
E3
ELEV.
E2
ELEV.
E1
STAIR
S02
JUDGE
JUDGE
JURY
DELIB.
TLT.
TLT.
TLT.
M.
TOILET
W.
TOILET
COURT
WAITING/JURY
ASSEMBLY
ELECT.
VENDING
CELL
DETAINEE
232.1
ATTORNEY
CONF.
WITNESS
WITNESS
WITNESS
PUBLIC
CORR.
ACT-2
8' - 0"
ACT-2
8' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-2
9' - 0"
HOLDING
CORR.
RESTRICTED
CORR.
CORR.
CORR.
CELL
ACT-1
9' - 0"
ACT-2
9' - 0"
ACT-1
9' - 0"
I.T.
ELECT.
AV
ACT-1
9' - 0"
ACT-1
10' - 0"
ACT-2
8' - 0"
ACT-2
8' - 0"
ACT-2
8' - 0"
VEST.
ACT-1
10' - 0"
ACT-2
10' - 0"
ACT 3
10' - 4"
ACT-1
10' - 0"
GWB-2
10' - 0"
GWB-2
10' - 0"
ACT-1
10' - 0"
ACT-1
10' - 0"
ACT-1
9' - 0"
VEST.
ACT-1
9' - 0"
A1.12
Sim
A1.12
Sim
A1.12
Sim
2101GWB-1
12' - 0"
ACT-2
10' - 0"
GWB-2
10' - 0"
BREAK
TLT.
M-1
27' - 3"
ACT-1
10' - 0"
TLT.
ACT-1
10' - 0"
ACT-2
9' - 0"
ACT-1
8' - 0"
JUDGE
ASSIST.
SECURE
TOILET
232.2
EVID.
ACT-2
10' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-4
10' - 0"
M-1 ACOUSTICAL METAL CEILING
2 x 2 ACOUSTICAL LAY-IN CEILING (TYP.)
REFLECTED CEILING LEGEND
2 x 2 ACOUSTICAL LAY-IN CEILING (OPTIMA)
2 x 2 VINYL-FACED ACOUSTICAL LAY-IN CEILING
ACT-1
ACT-2
ACT-3
2 x 4 WOOD SLAT GRILLEACT-4
GWB - ACOUSTICAL GWB-1
GWB - IMPACT RESISTANT W/
METAL MESH
GWB-2
GWB - FIRE RATED TYPE 'X'GWB-3
ACOUSTICAL METAL CLIP-ONACT-5
GWBGWB-4
NOTE: CLEAN-AGENT ROOM LOCATIONS ARE NOTED ON FINISH SCHEDULE
AND SHEETS A1.04.a, A1.04.b, A1.05a, A1.05b, A1.06a, A1.06b.
ELEV.
E3
ELEV.
E2
ACA 3
OFFICE
MANAGER
ELECT.
ELEV.
E1
COMM.
ATTORNEY
TLT.
TLT.
JAN.
BREAK
CIVIL CLERK
CRIMINAL
CLERK 1
PROBATE
CLERK 1
CONF.
BREAK
DEPUTY
CLERK
PROBATE
CLERK 2
CLERK OF
COURT
TLT.
LOBBY
102A
STAIR
S02
PUBLIC
SPACE
GENEALOGY
GENERAL
OFFICE
SUPPORT
C.A.
WAITING
CLERK 2
GENERAL
OFFICE
STAIR
S01
LOBBY
ENTRY
CLERK
WAITING
103A
CORR.
TLT.
TLT.
JAN.
CLERK 1
CORR.
VEST.
CORR.
CORR.
CORR.
CLERK
COUNTER
103B
RECEPTION
VCN
CL.
ACT-1
10' - 0"
ACT-1
9' - 0"
ACT-2
8' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
10' - 0"
LAND
RECORDS
VICTIM/
WITNESS
COMPUTER
ELECTRICAL
ACT-1
10' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-2
8' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
10' - 10"
A7.11
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
PRINT/ COPY
ACT-5
10' - 10 7/8"
ACT-1
8' - 4"
PARALEGAL
TLT.
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 6"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-2
8' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
CLERK 3
ACT-1
9' - 0"
ACT-1
9' - 0"
BOOK
KEEPER
ACT-1
9' - 0"
SECURITY
ACT-1
9' - 0"
ACT-1
9' - 0"
ACA 1
ACT-1
9' - 0"
ACT-1
9' - 0"
GENERAL
OFFICE
ACT-1
8' - 0"
ACA 2
ACT-1
9' - 0"
ACT-1
9' - 0"
ACA 4
ACT-1
9' - 0"
TLT.
ACT-2
8' - 0"
CURRENT
FILES
ACT-1
9' - 0"
CIVIL CLERK
ACT-1
9' - 0"
ACT-2
8' - 0"
ACT-2
8' - 0"
ACT-1
10' - 0"
ACT-1
10' - 0"
ACT-1
9' - 0"
CURRENT
FILES
TLT.
ACT-1
9' - 0"ACT-1
9' - 0"
WORK
TABLES/
SUPPORT
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
8' - 0"
ACT-2
8' - 0"
ACT-2
8' - 0"
A3.11c
ACT-1
9' - 0"
A1.12
ARCHITECT
C O M
MO
NW
EA
LTH OF VIRGIN
AIGARY E. HARVEY
Lic. No. 11908
DATE:
DESIGNED:
DRAWN:
CHECKED:
REVISIONS:
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A R
C H
IT
E
C T
U R
A L
P A
R T
N E
R S
P
.C
BO
TE
TO
UR
T
CO
UN
TY
N
EW
C
IR
C U
IT
C
O U
R
TH
O U
SE
W
ES
T M
AI
N
S T.
0, F
IN
C
AS
TL
E, V
A
O
JE
C
T N
O
/7
/2
5:
:1
PM
10/18/2024
JMT/BEG
KTG/BEG
GEH
BID SET
10/18/2024
A1.11
FIRST &
SECOND
FLOOR
REFLECTED
CEILING
PLANS
C C
H
TN PN
3/32" = 1'-0"A1.11
2 SECOND FLOOR REFLECTED CEILING PLAN
A1.11 NOTES
No. Note Text
2101 THE EXACT LOCATIONS OF CONCEALED SPRINKLER HEADS IN THE CEILING OF
THIS SPACE MUST BE COORDINATED WITH THE CEILING DESIGN REPRESENTED
ON THE REFLECTED CEILING PLANS SUCH THAT HEADS ARE SYMMETRICALLY
PLACED AND/OR CENTERED WITHIN THE SPACE, EITHER ON A CENTERLINE, OR
TO EITHER SIDE OF A NORTH/SOUTH CENTER LINE, AND/OR ON CENTER LINES
WITHIN A CEILNG TYPE. IT IS UNDERSTOOD THAT THESE EXACT
REQUIREMENTS FOR SYMMETRY MAY RESULT IN ADDITIONAL SPRINKLER
HEADS BEYOND THOSE NECESSARY FOR MEETING MINIMUM CODE
REQUIREMENTS. THE COST OF ANY SUCH ADDITIONAL HEADS, OR PIPING
REQUIRED FOR THESE HEADS, OR DESIGN SERVICES, OR ANY LABOR AND
MATERIAL AS PART OF THE FIRE SUPPRESSION SYSTEM REQUIRED TO PROVIDE
THESE ADDITIONAL HEADS FOR THE PURPOSE OF SYMMETRY IS TO BE A PART
OF THE GENERAL CONTRACTOR’S BASE BID. THE EXACT LOCATION AND
PATTERN OF SPRINKLER HEADS IN THESE SPACES IS TO BE CLEARLY
INDICATED ON SUBMITTALS, WITH NECESSARY NOTES AND DIMENSIONS, AND
APPROVED BY THE ARCHITECT. WORK PERFORMED AT VARIANCE WITH THE
APPROVED SUBMITTALS WILL NOT BE ACCEPTED FOR ANY REASON.
COORDINATION AMONG SUB-CONTRACTORS AND TRADES TO ACHIEVE
DESIGN REQUIREMENTS AND SUBMITTAL COMPLIANCE WILL REMAIN THE SOLE
RESPONSIBILITY OF THE GENERAL CONTRACTOR.
TN PN
3/32" = 1'-0"A1.11
1 FIRST FLOOR REFLECTED CEILING PLAN 0 5' 20'10' 40'
3/32" = 1'-0"
0 5' 20'10' 40'
3/32" = 1'-0"
No. Date 1 10/30/2024 2 11/7/2024
SEE SHEET A1.13 FOR TYPICAL BULKHEAD
AND CEILING TRANSITION DETAILS.
A7.02
A7.02
A7.02
A7.02
A7.02
A7.02
A1.13
A1.13
A1.13
A1.13
A1.13
+10' - 3"
GWB-1
12' - 4"
ACT 3
10' - 4"
ACT 3
10' - 4"
A7.01
A1.14
ACT 3
10' - 4"
A1.13
4' - 0" 2' - 0" 2' - 0" 4' - 0"
A7.02
A7.02
A7.02
A1.13
A1.13
A1.13
________________________ 3 A1.13
A7.01
+9' - 11"
GWB-1
12' - 4"
ACT 3
10' - 0"
ACT-2
10' - 0"
ACT-2
10' - 0"
ACT-2
10' - 0"
ACT 3
10' - 0"
ACT-2
10' - 0"
A7.02
A1.13
4' - 0" 2' - 0" 2' - 0" 4' - 0"
1/
A1.13
A1.13
A1.13
A1.13
A1.13
A1.13
A1.13
A1.13
+25' - 6"
+9' - 11"
GWB-1
12' - 0"
ACT-1
10' - 0"
ACT-1
10' - 0"
ACT-1
10' - 0"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
GWB-1
26' - 6"
+25' - 6"
+25' - 6"
+9' - 11"
/8
1/
1/
/2
1'
/8 " F
R O
M C
.L . O
F B
E A
M
11' - 7" 2' - 0" 11' - 1 5/8" 2' - 0" 11' - 7 5/8"
ACT-1
10' - 0"
A1.13
A1.13
M-1 ACOUSTICAL METAL CEILING
2 x 2 ACOUSTICAL LAY-IN CEILING (TYP.)
REFLECTED CEILING LEGEND
2 x 2 ACOUSTICAL LAY-IN CEILING (OPTIMA)
2 x 2 VINYL-FACED ACOUSTICAL LAY-IN CEILING
ACT-1
ACT-2
ACT-3
2 x 4 WOOD SLAT GRILLEACT-4
GWB - ACOUSTICAL GWB-1
GWB - IMPACT RESISTANT W/
METAL MESH
GWB-2
GWB - FIRE RATED TYPE 'X'GWB-3
ACOUSTICAL METAL CLIP-ONACT-5
GWBGWB-4
NOTE: CLEAN-AGENT ROOM LOCATIONS ARE NOTED ON FINISH SCHEDULE
AND SHEETS A1.04.a, A1.04.b, A1.05a, A1.05b, A1.06a, A1.06b.
GENERAL
OFFICE
GENERAL
OFFICE
CORR.
RECEPTION
VEST.
TLT.
A1.13
A1.13
A1.13
A1.13
ACT-1
10' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
A1.13
A1.13
1/
1/
/2
NOTE: ALIGN VERTICAL FACES OF BULKHEADS WITH VERTICAL FACES AND CORNERS OF WALLS BELOW
ARCHITECT
C O M
MO
NW
EA
LTH OF VIRGIN
AIGARY E. HARVEY
Lic. No. 11908
DATE:
DESIGNED:
DRAWN:
CHECKED:
REVISIONS:
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A R
C H
IT
E
C T
U R
A L
P A
R T
N E
R S
P
.C
BO
TE
TO
UR
T
CO
UN
TY
N
EW
C
IR
C U
IT
C
O U
R
TH
O U
SE
W
ES
T M
AI
N
S T.
0, F
IN
C
AS
TL
E, V
A
O
JE
C
T N
O
/7
/2
5:
:4
PM
10/18/2024
JMT/BEG
KTG
GEH
BID SET
10/18/2024
A1.12
ENLARGED
REFLECTED
CEILING PLAN
C C
H
TN PN
3/16" = 1'-0"A1.12
2 SECOND FLOOR - JURY COURTROOM RCP
TN PN
3/16" = 1'-0"A1.12
1 SECOND FLOOR - HEARING COURTROOM RCP
TN PN
3/16" = 1'-0"A1.12
3 SECOND FLOOR - COURT WAITING/JURY ASSEMBLY & LOBBY RCP
0 3' 12'6' 24'
3/16" = 1'-0"
0 3' 12'6' 24'
3/16" = 1'-0"
0 3' 12'6' 24'
3/16" = 1'-0"
NOTE:
• COORDINATE LOCATION OF AND FRAMING FOR
TYPE 'S' COVE LIGHTING IN COURTROOM AND
HEARING ROOM WITH ELECTRICAL
• COORDINATE LOCATION OF AND FRAMING FOR
TYPE 'R' LIGHTING WITH ELECTRICAL. THIS LIGHTING
IS TO BE INSTALLED BEHIND JUDGES BENCH
ABOVE THE COUNTY SEAL.
• WINDOW TREATMENTS TO BE PROVIDED AT EACH
WINDOW OF THE JURY COURTROOM. COORDINATE
INSTALLATION OF CEILING GRID AND TILE WITH
THESE WINDOW TREATMENTS. SEE DETAILS 1/A1.14.
• EXACTLY CENTER LIGHTS WITHIN CEILING PANELS
OR AS IN THE LOBBY EXACTLY CENTERED
BETWEEN THE COFFERS.
No. Date 1 10/30/2024 2 11/7/2024
TN PN
3/16" = 1'-0"A1.12
4 SECOND FLOOR - GEN OFFICE RCP
0 3' 12'6' 24'
3/16" = 1'-0"
702 406
1' - 7 5/8"
406 410
1'
/8
HOLDING CELL
THIS SIDE
1' - 3 5/8"
410 406
EQ EQ
/1
1/
2"
1' - 7 5/8" 1'
/8
9 1/2"
E Q
E Q
1' - 7 5/8"
EQ EQ
1'
/8
E Q
E Q
1' - 7 5/8"
1'
/8
1' - 7 5/8"
EQ EQ
/4
/8
1/
406 402
402410
426 702
406 402
ARCHITECT
C O M
MO
NW
EA
LTH OF VIRGIN
AIGARY E. HARVEY
Lic. No. 11908
DATE:
DESIGNED:
DRAWN:
CHECKED:
REVISIONS:
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
A R
C H
IT
E
C T
U R
A L
P A
R T
N E
R S
P
.C
BO
TE
TO
UR
T
CO
UN
TY
N
EW
C
IR
C U
IT
C
O U
R
TH
O U
SE
W
ES
T M
AI
N
S T.
0, F
IN
C
AS
TL
E, V
A
O
JE
C
T N
O
/7
/2
5:
:0
PM
10/18/2024
JMT/BEG
JRW
GEH
BID SET
10/18/2024
A1.40a
BASEMENT
FLOOR
COLUMN
DETAILS
C C
H
SEE STRUCTURAL GRID
A/1.2, A/8.2, D/1, D/8.9, SEE STRUCTURAL GRID
A/2.5, F.2/1, G/1, H/1, J.1/1, P/4.5, P/5.6, J/8.9, G.4/9, F/9
SEE STRUCTURAL GRID
A/5.8, A/7.2
SEE STRUCTURAL GRID
B/8.2
SEE STRUCTURAL GRID
F.5/2, F.5/4
SEE STRUCTURAL GRID
F/2, F/4
SEE STRUCTURAL GRID
D/1.2
SEE STRUCTURAL GRID
D/2.5
SEE STRUCTURAL GRID
G/6, G/8, H/1.7, H/4, H/6, H/8, J/6, J/8, J.5/2, J.5/4.3, L/3, L/5, L/7, M/3, M/5, M/7, N/5
SEE STRUCTURAL GRID
E/6, F/6
SEE STRUCTURAL GRID
K/4.5, K/5.6, K/7
SEE STRUCTURAL GRID
D.8/9
SEE STRUCTURAL GRID
D/8.2
SEE STRUCTURAL GRID
E/1
SEE STRUCTURAL GRID
N/3, N/7
SEE STRUCTURAL GRID
K/1
A1.40a NOTES No. Note Text
301 CONCRETE FOUNDATION WALL- SEE STRUCTURAL DRAWINGS
312 CONCRETE PIER (SEE STRCUTURAL DRAWINGS)
402 STONE VENEER - ABOVE GRADE ONLY
406 4" CMU
410 8" CMU - GROUT SOLID
418 GROUT
422 CMU PIER-BULLNOSE (SEE STRUCTURAL DRAWINGS FOR DETAILS)
426 12" CMU - GROUT SOLID
507 3 5/8" MTL STUDS @ 16"O.C.
702 2" RIGID INSULATION - R-10
802 HOLLOW METAL FRAME & GLAZING SYSTEM
806 HOLLOW METAL FRAME @ HEAD - GROUT SOLID
807 CUSTOM HOLLOW METAL DOOR: SEE A6.01 DOOR SCHEDULE
901 5/8" GWB - IMPACT RESISTANT
NOTE:
1. ALL CMU OUTSIDE CORNERS TO BE BULLNOSE
BLOCK. ALL CONCRETE OUTSIDE CORNERS TO BE
RUBBED.
2. SEE STRUCTURAL DRAWINGS FOR CMU & CONCRETE
PIERS AND STRUCTURAL STEEL COLUMNS
No. Date 1 10/30/2024 2 11/7/2024
1 1/2" = 1'-0"A1.40a
1 B.1 COLUMN DETAIL
1 1/2" = 1'-0"A1.40a
2 B.2 COLUMN DETAIL
1 1/2" =…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .