Addendum _1 IFB _493_25.pdf
PDF 10 MB Posted
- Solicitation number
- PE-64200-NONST-2026-000000071
- Issued by
- Douglas County, Georgia
About this file
Summary of IFB #493-25 Addendum #1 - Materials and Labor to Repair VMP Pavilion
This addendum document pertains to Invitation for Bid (IFB) #493-25 issued by Dawson County for materials and labor to repair the Veterans Memorial Park (VMP) Pavilion. The project involves structural repairs to the pavilion, specifically addressing timber replacement and related construction work. The IFB closing date is January 22, 2026, at 2:30 p.m., with the addendum issued on January 13, 2026, by Purchasing Manager Hanna Milford. The scope of work includes replacing bottom-chord members at specified truss joints, installing new cover plates at designated exterior truss connections, applying wood sealer to all existing and new wood members per specification, and providing all necessary shoring. The contractor is responsible for obtaining all permits and paying associated fees. Greater Georgia Contracting is identified as the current vendor providing existing shoring, which the contractor will remove with coordination between all involved parties. Contractors are permitted to use on-site restrooms during construction.
The project requires contractors to bid only the work specified in the construction documents, with any additional repairs identified as necessary to be submitted as separate line items on alternate pages of the Price Proposal Form with detailed descriptions and pricing. A bid bond is required regardless of project cost, and permits are mandatory for this project. Inspections will be conducted by Dawson County Community Development and the Engineer of Record, with no third-party inspection responsibility assigned to the general contractor. The project team includes Wakefield Beasley & Associates (architect), Foresite Group, Inc. (civil engineer), Shear Structural (structural engineer), and Griffith Engineering (mechanical/electrical/plumbing engineer). Original 2019 construction drawings for the pavilion are attached to the addendum to support the bidding process.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IFB _493_25.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IFB #493-25 MATERIALS AND LABOR TO REPAIR VMP PAVILION
ADDENDUM #1
IFB Closing Date: January 22, 2026, at 2:30 p.m.
IFB Addendum Issue Date: January 13, 2026 By: Hanna Milford, Purchasing Manager
The following are questions and answers to the IFB #493-25 Materials and Labor to Repair Veterans Memorial Park Pavilion
1. QUESTION: Who is the current vendor Dawson County has used for the shoring that is in place?
ANSWER: Greater Georgia Contracting
2. QUESTION: Note #1 on Sheet S-201 refers to Sheet S-001. Please provide sheet S-001.
ANSWER: Any reference to S-001 should be G-001
3. QUESTION: Will the contractors be able to utilize the restrooms that are on site?
ANSWER: Yes
4. QUESTION: Please verify that the contractor is responsible for permits and fees as noted on G-001.
ANSWER: Yes, the contractor is responsible for all permits and fees.
5. QUESTION: Sheets S-201 (East & West) and S-202 (North & South) show new cover places (A,B,C,D) at specific truss chord connection joints across all four exterior elevations. Please confirm which interpretation is correct and also, please confirm that no new cover plates are required at any interior truss chord connections:
A. Install new cover plates only at the bottom-chord replacement splice area B. Install new cover plates only at the specific exterior truss chord joints specified in Sheets S-201 and S-202, which include designated locations on all four exterior elevations
ANSWER: B is the correct interpretation.
6. QUESTION: The specification state that wood sealer is to be applies for all wood and all rough cut ends and drilled holes must be coated. Please confirm which scope is intended:
A. Apply sealer only on the new replacement bottom-chord members B. Apply sealer to all existing and new wood members throughout the entire pavilion, per the specification.
ANSWER: B is the correct interpretation
7. QUESTION: Will the existing plans be provided?
ANSWER: Attached to this addendum are the original drawings for the construction of the pavilion in 2019.
8. QUESTION: It seems that more members at the intersection where we are replacing timber seems to be rotted out and irreparable than is currently prescribed. Are we to bid what we believe will need to be replaced or just what the plans reflect?
ANSWER: Bid only what the plans reflect. For any additional repairs you believe may be necessary, please include those in your bid documents as an alternate on a separate page from the Price Proposal Form with the description of the repair and pricing.
9. QUESTION: Are the existing shores remaining in place?
ANSWER: No, the contractor will be responsible for providing their own shoring. The current shoring removal will be coordinated between contractors.
10. QUESTION: Will a permit be required for this project?
ANSWER: Yes
11. QUESTION: Will a bond be required if under 100k?
ANSWER: Yes, a bid bond is required for this project.
12. QUESTION: Is the GC responsible for any 3rd party inspections?
ANSWER: No, inspections will be completed by Dawson County Community Development, and the Engineer of Record.
Company Name Signature of Authorized Representative
Title Date
THIS DOCUMENT MUST BE COMPLETED AND SUBMITTED AS PART OF YOUR PROPOSAL
PROJECT TEAM
5200 AVALON BOULEVARD
ALPHARETTA, GEORGIA 30009
PHONE: 770.209.9393
CONTACT: CHRISTIAN SPRINGFIELD
EMAIL: cspringfield@wbassociates.com
ARCHITECT:
WAKEFIELD BEASLEY & ASSOCIATES, INC.
3740 DAVINCI CT
SUITE 100
PEACHTREE CORNERS, GA 30092
PHONE: 770.368.1399
CONTACT: JACK JOHNSON
EMAIL: jjohnson@fg-inc.net
CIVIL ENGINEER:
FORESITE GROUP, INC.
931 MONROE DRIVE
SUITE A102-491
ATLANTA, GA 30308
PHONE: 404.735.3712
CONTACT: KAREN JENKINS
EMAIL: kjenkins@shearstructural.com
STRUCTURAL ENGINEER:
SHEAR STRUCTURAL
MECH./ ELECT./ PLUMB./ FP ENGINEER:
GRIFFITH ENGINEERING
4360 CHAMBLEE DUNWOODY RD
SUITE 210
PHONE: 770.451.6757
CONTACT: TRIP WALTERS
EMAIL: twalters@griffitheng.com
25 JUSTICE WAY, SUITE 2223
DAWSONVILLE, GA 30534
PHONE: 706.344.3500 ext. 42223
CONTACT: MELISSA HAWK
EMAIL: mhawk@dawsoncounty.org
OWNER:
DAWSON COUNTY BOARD OF COMMISSIONERS
ATLANTA, GA 30303
GENERAL NOTES
LOCATION MAP
TRUE NORTH
SITE LOCATION
VINYL WALL COVERING
WELDED WIRE FABRIC
GENERAL CONTRACTOR
INSTALLED BY CONTRACTOR
FIBERGLASS REINFORCED POLYESTER
FURNISHED BY OWNER INSTALLED
BY CONTRACTOR
FIRE EXTINGUISHER CABINET
GYPSUM WALL BOARD
HEIGHT
HOLLOW METAL
GWB
HT
I.B.C.
H.M.
FRANCHISEE
FACE OF MASONRY
FLOOR
FINISH FLOOR
FIRE RETARDANT
G.C.
FRAN.
FRP
F.R.
F.O.M.
FL.
F.F.
FEC
VERT.
W.W.F.
W
W/
VWC
WD.
VERTICAL
WOOD
WITH
WIDE
NOT TO SCALE
NOT IN CONTRACT
NON-COMBUSTIBLE
PRESSURE TREATED
ROOF DRAIN
SUPPLIED BY OWNER
PLASTIC LAMINATE
OVERFLOW DRAIN
STRUCTURAL
MECHANICAL
UNLESS NOTED OTHERWISE
TONGUE AND GROOVE
CONCRETE MASONRY UNIT
ELECTRIC WATER COOLER
EQUIPMENT SUPPLIER
DRAWING
DOWN SPOUT
ELECTRIC
EXPANSION
EXTERIOR
ELEVATION
FLOOR DRAIN
E.S.
EXP.
E.W.C.
EXT.
F.D.
ELEV.
EA.
DWG.
D.S.
ELEC.
EACH
BRICK
CENTER LINE
BEARING
COLUMN
CONCRETE
COORDINATE
DIAMETER
CONTINUOUS
CONTROL JOINT
COORD.
COL
CONC.
CONT.
BR
C.L.
C.J.
BRG
C.M.U.
SCHED.
S.B.O.
STRUCT.
T/
T&G
TYP.
UNO
R.D.
STL.
SIM.
TOP OF
TYPICAL
SCHEDULE
STEEL
SIMILAR
PLYWD.
PL.
P.T.
O.C.
PR.
N.I.C.
NC.
O.D.
OPP.
N.T.E.
PAIR
PLYWOOD
ON CENTER
OPPOSITE
ABOVE FINISHED FLOOR
ACOUSTICAL TILE
ALUMINUM
BOARD
BUILDING
BOTTOM OF
ALUM.
A.F.F.
BD.
BLDG.
B/
ACT
@ AT
MECH.
MAT.
MAX.
MIN.
MTL.
L.L.
JT.
MATERIAL
MAXIMUM
MINIMUM
METAL
LANDLORD
JOINT
COLD FORMED METAL FRAMINGCFMF
NOT TO EXCEED
N.T.S.
FACE OF FINISHF.O.F.
FACE OFF.O.
CLEARCLR
FOIC
A-3.1
WOOD DIMENSIONAL
ROOM NAME & NUMBER
COLUMN AND GRID NUMBER
DOOR REFERENCE
NUMBER SEE SHEET A8.1
SOLID GROUT
'SIM' - SIMILAR
SECTION MARK
ENLARGED PLAN /
DETAIL MARK
'OH' - OPPOSITE HAND
ELEVATION MARK
WINDOW REFERENCE
NUMBER SEE SHEET A8.1
FLOOR FINISH
SHEATHING
RIGID INSULATION
BATT INSULATION
PLASTER, GYPSUM
WALLBOARD
EARTH
CONCRETE
WOOD
STEEL, IRON
BRICK
GRANULAR
C123
OFFICE
PT
A
MORTAR NET
A101
SYMBOLS
ABBREVIATIONS
Nelco Architecture, Inc.
a licensed affiliate of Nelson Worldwide, LLC.
DESIGNING ARCHITECT
ARCHITECT OF RECORD
RELEASED FOR CONSTRUCTION
COPYRIGHT AND REPRODUCTION NOTICE
© 2018 Wakefield Beasley & Associates Architects, Inc.
These drawings are protected by the copyright laws of the
United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of WBA.
F
IL
E N
A M
E
S H
E E
T N
A M
E
SHEET NUMBER
DATE
SHEET TITLE
DAWSON
COUNTY
PAVILION
Print Record
PROJECT NUMBER
Revisions
No. Date Description
2019-01-14 SCHEMATIC DESIGN PACKAGE
2019-02-19 CONSTRUCTION DOCUMENTS 100%
/1
/2
:3
:4
P
M C
U s e rs
\s is k a n d e r\
D o c u m e n ts
\M y R e v it P ro je c ts
\2 \1
D a w s o n C o u n ty
P a v ili o n \1
D a w s o n C o u n ty
P a v ili o n -X
A M
-J U
S s is k a n d e r.
rv t
201 RECREATION RD
DAWSONVILLE, GA 30534
February 19, 2019
COVER SHEET
G0-01
C O
V E
R S
H E
E T
S
H E
E T
N U
M B
E R
G
-0
P
R O
J E
C T
N A
M E
P
R O
J E
C T
N A
M E
1816000.000
DAWSON COUNTY PAVILION
SHEET LIST
SHEET NUMBER Sheet Name 2
-0
-1
C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
01 GENERAL
G0-01 COVER SHEET X
G0-02 ADAAG REGULATORY SIGNAGE, OTHER SIGNAGE, & TYPICAL MOUNTING HEIGHTS X
G0-03 HANDICAPPED ACCESSIBILITY DIAGRAMS X
02 CIVIL
G-2 CONSTRUCTION RESPONSIBILITY PLAN X
03 STRUCTURAL
S0-01 GENERAL NOTES X
S0-02 COMPONENTS AND CLADDING X
S1-10 FOUNDATION PLAN X
S1-70 ROOF FRAMING PLAN X
S3-01 FOUNDATION DETAILS X
S6-01 WOOD FRAMING DETAILS X
S6-02 WOOD FRAMING DETAILS X
S6-03 ROOF TRUSS PROFILES X
04 ARCHITECTURAL
A1-10 REFERENCE FLOOR PLAN X
A1-21 ENLARGED RESTROOM BUILDING PLANS & SECTIONS X
A1-31 REFLECTED CEILING PLAN X
A1-70 ROOF PLAN X
A2-00 EXTERIOR ELEVATIONS X
A2-01 EXTERIOR ELEVATIONS X
A3-10 WALL SECTIONS X
A6-10 COLUMN & CAST STONE DETAILS X
A6-11 ROOF DETAILS X
A7-00 DOOR SCHEDULE, ELEVATIONS, & DETAILS X
A7-10 WINDOW SCHEDULE, ELEVATIONS & DETAILS X
05 INTERIORS
I0-01 FINISH PLAN, DETAILS, NOTES, & LEGEND X
I0-02 FINISH ELEVATIONS X
06 MECHANICAL
M0-01 MECHANICAL NOTES X
M1-01 MECHANICAL FLOOR PLAN X
07 PLUMBING
P0-01 PLUMBING NOTES, SCHEDULE, AND LEGEND X
P1-01 PLUMBING FLOOR PLAN X
P1-02 PLUMBING FLOOR PLAN X
P5-01 PLUMBING SCHEDULE & DETAILS X
P6-01 PLUMBING RISERS X
08 ELECTRICAL
E0-01 ELECTRICAL NOTES & LEGEND X
E1-01 PAVILION POWER PLAN X
E1-02 PAVILION LIGHTING PLAN X
201 RECREATION RD
DAWSONVILLE, GA 30534
100% CONSTRUCTION DOCUMENTS
1 DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY. FOR DIMENSIONS
NOT SHOWN OR IN QUESTION, CONTRACTOR SHALL REQUEST
CLARIFICATION FROM ARCHITECT BEFORE PROCEEDING.
2 UNLESS OTHERWISE NOTED, INTERIOR PARTITION DIMENSIONS ARE GIVEN
FROM FACE OF METAL STUD FRAMING/CMU TO FACE OF METAL STUD
FRAMING/CMU, OR FROM FACE OF METAL STUD FRAMING/CMU TO COLUMN
CENTERLINE. EXCEPTION: MILLWORK DETAILS WHERE DIMENSIONS ARE
FROM FACE OF FINISH SURFACES (GWB, PLASTER, ETC.).
3 ELEVATIONS AND LEVELS ARE SHOWN FROM FINISH FLOOR ELEVATION
(F.F.E. 0'-0" = 993.30') TARGET ELEVATIONS ARE BASED ON A "REFERENCE
BENCHMARK ELEVATION" -COORDINATE ELEVATION OF FINISHED FLOOR
HEIGHT WITH CIVIL AND STRUCTURAL DRAWINGS.
4 ELECTRIC PANELS, ALARM BOXES, FIRE EQUIPMENT CABINETS AND OTHER
RECESSED BOXES GREATER THAN 16 SQUARE INCHES THAT ARE LOCATED
IN RATED WALLS SHALL BE BACKED BY GYPSUM WALLBOARD LAYERS
SUFFICIENT TO MAINTAIN THE DESIGNATED RATING. FEC'S MAY BE
PROIDED WITH A RATED CABINET TO MATCH THE DESIGNATED RATING.
5 ATTIC ACCESS FROM AN ADJACENT SPACE SHALL BE PROVIDED WHERE
THE BELOW ITEMS OCCUR OVER GWB CEILINGS:
A. VALVES
B. FLOW MEASURING DEVICES
C. MIXING BOXES
D. POWER OPERATED DAMPERS
E. ACCESS PANELS IN DUCTWORK
F. VOLUME AND BALANCING DEVICES
G. WATER FLOW SWITCHES
H. SPRINKLER SYSTEM DRAINS AND TEST CONNECTIONS
I. PRESSURE SWITCHES
6 PATCH AND REPAIR ALL ITEMS DAMAGED OR ALTERED DURING
CONSTRUCTION. ALL PATCHES SHALL BLEND WITH ADJACENT MATERIAL,
COLOR, FINISH, AND TEXTURE. ALL EXISTING WORK FURNISHINGS,
EQUIPMENT OR MATERIAL TO REMAIN THAT ARE DAMAGED BY THE
CONTRACTOR'S OPERATION SHALL BE REPAIRED AT NO ADDITIONAL COST
TO THE OWNER.
1'
1'
STANDING
DRINKING
FOUNTAIN
STANDARD
URINAL
STANDARD
TOILET
FINISHED FLOOR
3'
3'
2'
FINISHED FLOOR
SOAP DISPENSER TOWEL DISPENSER SANITARY NAPKIN
DISPOSAL
HAND DRYER
3'
NOTE: TOILET ACCESSORIES ARE SHOWN FOR MOUNTING HEIGHTS ONLY AND DO NOT REPRESENT ACTUAL FIXTURES SPECIFIED. SEE PLUMBING DRAWINGS AND ENLARGED TOILET PLANS, ELEVATIONS & TOILET ACCESSORY SCHEDULES FOR
DETAILS. SEE SHEET G-003 FOR REQUIRED HANDICAPPED HEIGHTS AND CLEARANCES.
4'
4'
O F
C O
IN
S
LO
T
T O
C E
N T
E R
LI
N
E
T O
W E
L E
X T
R A
C T
IO
N
T O
P A
P E
R
32" MIN.
5'
SANITARY
NAPKIN/
VENDOR
TOWER
DISPENSER AND
WASTE
RECEPTACLE
MOP AND
BROOM HOLDER
FIRE EXTINGUISHER FIRE EXTINGUISHER
CABINET
3'
M A
X
3'
M
IN
3'
6"
" H
O
LD
M
AX
3'
0"
STANDARD
DRINKING
FOUNTAIN
*PROVIDE CANE
APRON AT
CORRIDOR
LOCATIONS
OPERABLE PART
NO
1/8"INTER-CELL SPACING
WITHIN A CELL = 0.10"
(VERTICAL OF HORIZONTAL)
1/4"INTER-CELL SPACING 0.20"
BRAILLE DOT
ROUNDED DOT
(ACCEPTABLE)
SQUARED DOT
(NOT ACCEPTABLE)
RECOMMENDED ROUNDED OR DOMED BRAILLED DOTS, EACH DISTINCT
AND SEPARATE. DOTS WITH STRAIGHT SIDES AND FLAT TOPS ARE NOT
READABLE FOR MANY BRAILLE USERS.
3/ 8"
1. CHARACTER TYPE: CHARACTERS ON SIGNS SHALL BE RAISED 1/32"MINIMUM AND SHALL BE SANS
SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE II BRAILLE.
2. CHARACTER SIZE: RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8"(15.9mm) AND A MAXIMUM OF 2" (51mm) HIGH.
3. FINISH AND CONTRAST: CONTRAST BETWEEN CHARACTERS, SYMBOLS AND THEIR BACKGROUND
MUST BE 70% MINIMUM AND HAVE A NON-GLARE FINISH.
4. PROPORTIONS: CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5
AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO OF BETWEEN 1:5 AND 1:10.
ALL LETTERS MEASURED MUST BE UPPERCASE. AFTER CHOOSING A TYPESTYLE TO TEST, BEGIN BY PRINTING THE LETTERS I, X AND O AT 1 INCH HIGH. PLACE THE TEMPLATE'S 1:1 SQUARE OVER THE X
OR O, WHICHEVER IS NARROWER. IF THE CHARACTER IS NOT SMALLER THAN 1 INCH, NOR
NARROWER THAN THE 3:5 RECTANGLE TO DETERMINE IF THE STROKE OF THE I IS TOO BROAD, AND THE 1:10 RECTANGLE TO SEE IF IT IS TOO NARROW. IF ALL THE TESTS ARE PASSED, THE TYPESTYLE
IS COMPLIANT WITH PROPORTION CODE.
TEMPLATE FOR CHECKING CHARACTER AND STROKE WIDTH TO HEIGHT PROPORTIONS
1:1 100%
3:5 60%
1:5 20%
1:10 10%
CHARACTER WIDTH STROKE WIDTH
5. BRAILLE: GRADE II BRAILLE SHALL BE USED WHENEVER BRAILLE IS
REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE
1/10"(2.54mm) ON CENTERS IN EACH CELL WITH .241"(5.08mm) SPACE
BETWEEN CELLS, MEASURED M CELL. DOTS SHALL BE RAISED A MINIMUM
OF
1/4" (0.635mm) ABOVE THE BACKGROUND.
0.
1/
BRAILLE CELL
REF: ADA 4.30
ANSI 703.4
1 RESTROOM IDENTIFICATION SYMBOL. COLOR TO CONTRAST w/ DOOR FINISH
SYMBOL BACKGROUND - 1/4" THICK MATTE ACRYLIC BACK PAINTED COLOR TO CONTRAST w/ DOOR FINISH
CORRESPONDING GRADE II BRAILLE
SYMBOL OF ACCESSIBILITY
6"
2"MEN
6"
1/4" RADIUS, TYP.
M O
U N
T
IN
G H
E
IG
H T
0"
EQ
1"
M
AX
EQ
1 RESTROOM IDENTIFICATION SYMBOL. COLOR TO CONTRAST w/ DOOR FINISH
SYMBOL BACKGROUND - 1/4"THICK MATTE ACRYLIC BACK PAINTED COLOR TO CONTRAST w/ DOOR FINISH
CORRESPONDING GRADE II BRAILLE
SYMBOL OF ACCESSIBILITY
6"
2"FAMILY
7"
1/4" RADIUS, TYP.
M O
U N
T
IN
G H
E
IG
H T
0"
EQ
1"
M
AX
EQ
5'
A F
F
WALL MOUNTED SIGN TYPE B
0' - 6" 1' - 0"
1 RESTROOM IDENTIFICATION SYMBOL. COLOR TO CONTRAST w/ DOOR FINISH
SYMBOL BACKGROUND - 1/4"THICK MATTE ACRYLIC BACK PAINTED COLOR TO CONTRAST w/ DOOR FINISH
CORRESPONDING GRADE II BRAILLE
SYMBOL OF ACCESSIBILITY
6"
2"WOMEN
6"
1/4" RADIUS, TYP.
M O
U N
T
IN
G H
E
IG
H T
0"
EQ
1"
M
AX
EQ
A. SYMBOL PROPORTIONS
B. DISPLAY CONDITIONS
NOTE:
SYMBOL SIZE SHALL BE AS SCHEDULED IN SIGN LAYOUT
DIAGRAMS.
STROKE WIDTH TO HEIGHT RATIO SHALL BE BETWEEN
1:5 & 1:10.
SIGN LETTERS/ NUMBERS WIDTH TO HEIGHT RATIO
SHALL BE BETWEEN 1:5 & 1:10.
REF: ADA
4.30, FIG. 30,
ANSI 703.6
DIE CUT ALUMINUM LETTERS;
FONT TYPE: META BOLD
ITALIC, LOWERCASE
WOOD TRIM FASTENED TO
BOARD & BATTEN TO CREATE
SIGNAGE LEDGE
1'
6"
11"
2" 6"
0' - 6" 1' - 0"
5'
0" A
FF
SIGN TYPE A-3
DIE CUT ALUMINUM LETTERS;
FONT TYPE: META BOLD
ITALIC, LOWERCASE
WOOD TRIM FASTENED TO
BOARD & BATTEN TO CREATE
SIGNAGE LEDGE
1'
6"
11"
6" 2"
0' - 6"1' - 0"
5'
0" A
FF
SIGN TYPE A-2
Nelco Architecture, Inc.
a licensed affiliate of Nelson Worldwide, LLC.
DESIGNING ARCHITECT
ARCHITECT OF RECORD
RELEASED FOR CONSTRUCTION
COPYRIGHT AND REPRODUCTION NOTICE
© 2018 Wakefield Beasley & Associates Architects, Inc.
These drawings are protected by the copyright laws of the
United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of WBA.
F
IL
E N
A M
E
S H
E E
T N
A M
E
SHEET NUMBER
DATE
SHEET TITLE
DAWSON
COUNTY
PAVILION
Print Record
PROJECT NUMBER
Revisions
No. Date Description
2019-01-14 SCHEMATIC DESIGN PACKAGE
2019-02-19 CONSTRUCTION DOCUMENTS 100%
/1
/2
:3
:4
P
M C
U s e rs
\s is k a n d e r\
D o c u m e n ts
\M y R e v it P ro je c ts
\2 \1
D a w s o n C o u n ty
P a v ili o n \1
D a w s o n C o u n ty
P a v ili o n -X
A M
-J U
S s is k a n d e r.
rv t
201 RECREATION RD
DAWSONVILLE, GA 30534
February 19, 2019
ADAAG REGULATORY
SIGNAGE, OTHER
SIGNAGE, & TYPICAL
MOUNTING HEIGHTS
G0-02
A D
A A
G R
E G
U L A
T O
R Y
S
IG
N A
G E
O
T H
E R
S
IG
N A
G E
T Y
P
IC
A L M
O U
N T
IN
G
H E
IG
H
E
E T
N U
M B
E R
G
-0
P
R O
J E
C T
N A
M E
P
R O
J E
C T
N A
M E
1816000.000
SCALE: 1/4" = 1'-0"
STANDARD FIXTURE MOUNTING HEIGHTS
SCALE: 1 : 1
BRAILLE REQUIREMENTS
SCALE: 3" = 1'-0"
SIGN TYPE A-3 - RESTROOM
SCALE: 3" = 1'-0"
SIGN TYPE A-1 - RESTROOM
SCALE: 1/2" = 1'-0"
CODE REQUIRED SIGN
MOUNTING DIAGRAM
SCALE: 3" = 1'-0"
SIGN TYPE A-2 - RESTROOM
SCALE: 1 : 1
INTERNATIONAL ACCESSIBILITY
SYMBOL
SIGNAGE:
1. ALL SIGNAGE SHALL MEET THE REQUIREMENTS OF THE 2010
FEDERAL HANDICAPPED ACCESSIBILITY GUIDELINES.
2. PROVIDE ALL CODE REQUIRED SIGNAGE AT THE FOLLOWING
LOCATIONS: ALL TOILETS AND RESTROOMS, MECHANICAL ROOMS,
ELECTRICAL ROOMS, EQUIPMENT ROOMS.
SCALE: 1/2" = 1'-0"
MEN'S RESTROOM SIGNAGE
SCALE: 1/2" = 1'-0"
WOMEN'S RESTROOM SIGNAGE
Nelco Architecture, Inc.
a licensed affiliate of Nelson Worldwide, LLC.
DESIGNING ARCHITECT
ARCHITECT OF RECORD
RELEASED FOR CONSTRUCTION
COPYRIGHT AND REPRODUCTION NOTICE
© 2018 Wakefield Beasley & Associates Architects, Inc.
These drawings are protected by the copyright laws of the
United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of WBA.
F
IL
E N
A M
E
S H
E E
T N
A M
E
SHEET NUMBER
DATE
SHEET TITLE
DAWSON
COUNTY
PAVILION
Print Record
PROJECT NUMBER
Revisions
No. Date Description
2019-01-14 SCHEMATIC DESIGN PACKAGE
2019-02-19 CONSTRUCTION DOCUMENTS 100%
/1
/2
:3
:4
P
M C
U s e rs
\s is k a n d e r\
D o c u m e n ts
\M y R e v it P ro je c ts
\2 \1
D a w s o n C o u n ty
P a v ili o n \1
D a w s o n C o u n ty
P a v ili o n -X
A M
-J U
S s is k a n d e r.
rv t
201 RECREATION RD
DAWSONVILLE, GA 30534
February 19, 2019
HANDICAPPED
ACCESSIBILITY
DIAGRAMS
G0-03
H A
N D
IC
A
P P
E D
A C
C E
S S
IB
IL
IT
Y
D
IA
G R
A M
S
S
H E
E T
N U
M B
E R
G
-0
P
R O
J E
C T
N A
M E
P
R O
J E
C T
N A
M
1816000.000
F
O
O
T
P
R
I
N
T
S
E
N
I
O
R
C
N
T
E
R
S
T
O
Y
B
I
K
U
I
L
D
I
N
G
GATE
P
A
V
E
M
E
N
T
C
O
N
C
R
E
T
E
A
S
P
H
A
L
R
B
M
E
T
A
E
D
R
I
P
R
A
P
F
F
E
W
O
D
W
L
L
S
I
D
E
W
A
L
K
C
R
E
A
T
I
N
A
D
C
O
N
C
R
E
T
E
B
R
I
L
L
R
A
M
P
W
O
N
C
E
W
O
N
C
E
O
R
B
I R
E
W
O
N
C
E
F
F
E
A
S
P
H
A
L
T
A
P
P
R
O
X
I M
A
P
O
P
E
R
N
E
C
I
M
I T
S
C
I
W
S
O
N
V
I L
L
E Z
O
N
C
I
M
I T
S
R
D
E
D
G
P
H
A
L
T
E
D
P
H
A
L
T
X
A
S
P
H
A
A
I L
C
O
N
C
R
E
T
E
C
A
N
O
P
Y
W
O
O
D
D
E
C
K
A
S
P
H
A
L
T
T O
H
IG
H W
A Y
A
S
P
H
A
I V
E
A
P
P
R
O
X
I M
A
O
P
E
R
N
E
Z
O
N
S
D
A
W
S
U
N
T
Y
C
I
W
S
O
N
V
I L
L
E
Z
O
N
Z
O
N
S
D
A
W
S
U
N
T
Y
M
A
R
G
A
V
E
R
T
RECREATION ROAD
L
A
N
D
S
C
A
R
I P
B
U
I L
D
I
T
B
A
C
K
CU
A H
U
F
B A
T T
I N
G
C
A G
E
A
S
P
H
A
I V
E
F
L
A
G
P
O
L
E
G A
T E
F
O
L
L
P
O
L
E
T
R
A
S
H
C
A
N
G
A
T
E
S
C
O
R
E
B
O
A
R
D
B
E
N
C
H
ASPHALT DRIVE
A
S
P
H
A
I
V
E
6'C H
A
IN
-LIN
K
F E
N C
E
A
S
P
H
A
I
V
E
C
H
A
I
N
L
I
N
C
E
P
L
A
N
T
E
R
A
S
P
H
A
I
V
E
E
D
A
V
E
L
3' WOOD
A
S
P
H
A
L
T
R
U
N
N
I
A
C
K
O
V
E
R
H
A
N
G
R
E
S
T
R
O
O
M
S
S
T
O
R
Y
B
L
O
I
L
D
I
N
G
C
R
O
S
S
T
R
D
E
R
C
O
N
C
R
E
T
E
P
A
D
C
O
N
C
B
A
S
E
B
A
E
L
D
LOD
LOD
LO
D
LOD
LOD
LO
D
LO
D
LOD LO
D
LO
D
LOD
LOD
LO
D
LO
D
LO
D
LODLOD
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD
LOD LOD
LOD
LOD
LOD
LOD LOD
LOD
LOD LOD LOD LOD
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD LOD
LOD LOD LOD
LODLOD
LOD
LOD
LOD
LOD
LOD
LO
D
LOD
LO
D
LOD
LO
D
LO
D
LOD
LOD
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LODLOD
LOD
LOD
LO
D
LOD
LOD
LO
D
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LODLO
D
LO
D
LOD
SENIOR
CENTER
A
C
E
S
F
F
E
PAVILION
F
E
E
201 RECREATION RD
DAWSONVILLE, GA 30534
COPYRIGHT AND REPRODUCTION NOTICE
© 2018 Wakefield Beasley & Associates Architects, Inc.
These drawings are protected by the copyright laws of the
United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of WBA.
RELEASED FOR CONSTRUCTION
SHEET NUMBER
DATE
SHEET TITLE
Print Record
PROJECT NUMBER
Revisions
No. Date Description
2019-01-14 SCHEMATIC DESIGN PACKAGE
Nelco Architecture, Inc.
a licensed affiliate of Nelson Worldwide, LLC.
DESIGNING ARCHITECT
ARCHITECT OF RECORD
2019-02-04 BID PACKAGE
F I L
E N
A M
E
S H
E E
T
N
A M
E
DAWSON
COUNTY
SENIOR
CENTER
AND PAVILION
2019-03-08 GRANT REVIEW DOCUMENTS
D a w s o n
S e n i o r
C e n t e r
D a w s o n
C o u n t y
G
A D
W G
G
R e s p o n s i b i l i t y
P l a n d w g
CONSTRUCTION
RESPONSIBILITY
PLAN
G-2
SCALE IN FEET
100'50'25'50'
1"=50'
N
A
D
A
A
Z
N
E
LIMITS OF CONSTRUCTION, TYP.
CONTRACTOR RESPONSIBILITY NOTES:
SITEWORK CONTRACTOR RESPONSIBILITIES:
1. ALL DEMOLITION.
2. ALL GRADING, EARTHWORK, STORMWATER MANAGEMENT AND DRAINAGE
INFRASTRUCTURE INCLUDING ROOF DRAINS STUBBED AT 5' OUTSIDE THE
BUILDING ENVELOPE.
3. SITEWORK CONTRACTOR IS RESPONSIBLE TO BRING THE BUILDING PADS TO
GRADE IN ACCORDANCE WITH THE REPORT OF SUBSURFACE EXPLORATION AND
GEOTECHNICAL ENGINEERING PREPARED BY GEOHYDRO ENGINEERS, DATED
APRIL 3, 2018.
4. ALL UTILITIES STUBBED AT 5' OUTSIDE BUILDING ENVELOPE (INCLUDING
UNDERGROUND ROOF DRAINAGE LINES). SITE WORK CONTRACTOR IS
RESPONSIBLE FOR ALL COSTS AND COORDINATION WITH UTILITY PROVIDERS FOR
INSTALLATION OF SERVICES, RELOCATION AND/OR MODIFICATION OF SERVICES.
5. SITEWORK CONTRACTOR IS RESPONSIBLE FOR TRANSFORMER PAD. BUILDING
CONTRACTOR RESPONSIBLE FOR ALL OTHER BUILDING UTILITY EQUIPMENT PADS,
SEE NOTES BELOW.
6. ALL RETAINING WALLS, FENCES AND GUARDRAILS (SEE BUILDING STRUCTURAL
PLANS FOR FENCE CONNECTION DETAIL TO TOP OF RETAINING WALL).
7. ALL PLAYGROUND INFRASTRUCTURE UNLESS OTHERWISE NOTED HERE ON.
8. ALL AMPHITHEATER INFRASTRUCTURE.
9. ALL CURB AND GUTTER.
10. ALL CONCRETE SIDEWALK, UNLESS OTHERWISE NOTED IN THE RESPONSIBILITY
EXHIBIT.
11. ALL ROADWAY, TRAIL, AND PARKING LOT ASPHALT PAVING TO THE BINDER
COURSE OF ASPHALT. THE BUILDING CONTRACTOR WILL BE RESPONSIBLE TO
INSTALL THE FINISH COURSE OF ASPHALT AT THE COMPLETION OF
CONSTRUCTION.
12. ALL LANDSCAPING AND IRRIGATION.
13. ALL PAVEMENT STRIPING AND SIGNAGE.
14. REPLACEMENT OF ANY IMPROVEMENTS INSTALLED BY THE BUILDING
CONTRACTOR THAT ARE DAMAGED BY SITEWORK CONTRACTOR DURING
CONSTRUCTION.
15. ALL OTHER SITEWORK INDICATED IN THE PLANS AND SPECIFICATIONS NOT
COVERED BY THE BUILDING CONTRACTOR.
BUILDING CONTRACTOR RESPONSIBILITY AREA
INDICATED WITH HATCHING. GENERALLY BUILDING
CONTRACTOR IS RESPONSIBLE FOR BUILDING AND
ALL WORK WITHIN 5' OF BUILDING. SEE NOTES ON
THIS SHEET FOR MORE INFORMATION.
SITEWORK CONTRACTOR IS RESPONSIBLE FOR ALL
WORK OUTSIDE HATCHED AREAS. SEE NOTES ON
THIS SHEET FOR MORE INFORMATION.
BUILDING CONTRACTOR IS REPONSIBLE FOR
INSTALLATION OF SIDEWALKS IN HATCHED AREA
BUILDING CONTRACTOR RESPONSIBILITIES:
1. COMPLETE BUILDING PER BUILDING PLANS.
2. UTILITY CONNECTIONS TO BUILDING.
3. HVAC AND OTHER EQUIPMENT PADS EXCEPT TRANSFORMER PAD. SEE NOTES
ABOVE.
4. DOWNSPOUT CONNECTIONS TO UNDERGROUND ROOF DRAINAGE LINES.
5. CONCRETE PAVEMENT IN PORTE COCHERE AREA.
6. PORTIONS OF CONCRETE SIDEWALK INDICATED IN THE RESPONSIBILITY EXHIBIT.
7. INSTALLATION THE FINISH COURSE OF ASPHALT AT THE COMPLETION OF
CONSTRUCTION.
8. REPLACEMENT OF ANY SIDEWALK, CURBS OR OTHER IMPROVEMENTS INSTALLED
BY THE SITEWORK CONTRACTOR THAT ARE DAMAGED BY BUILDING CONTRACTOR
DURING CONSTRUCTION.
BUILDING CONTRACTOR IS REPONSIBLE FOR
INSTALLATION OF SIDEWALKS IN HATCHED AREA
BUILDING CONTRACTOR IS RESPONSIBLE FOR
INSTALLATION OF CONCRETE RAMP INTO
PLAYGROUND AREA
SITEWORK CONTRACTOR IS REPONSIBLE FOR ALL
RETAINING WALLS, FENCES AND GUARDRAILS, TYP.
1. NO PROVISION OF ANY REFERENCED STANDARD SPECIFICATION, MANUAL OR CODE (WHETHER OR
NOT SPECIFICALLY INCORPORATED BY REFERENCE IN THE CONTRACT DOCUMENTS) SHALL BE
EFFECTIVE TO CHANGE THE DUTIES AND RESPONSIBILITIES OF OWNER, CONTRACTOR, DESIGN
PROFESSIONAL, SUPPLIER, OR ANY OF THEIR CONSULTANTS, AGENTS, OR EMPLOYEES FROM THOSE SET FORTH IN THE CONTRACT DOCUMENTS. NOR SHALL IT BE EFFECTIVE TO ASSIGN TO THE DESIGN PROFESSIONAL OF RECORD OR ANY OF THE DESIGN PROFESSIONAL OF RECORD'S CONSULTANTS, AGENTS, OR EMPLOYEES ANY DUTY OR AUTHORITY TO SUPERVISE OR DIRECT THE FURNISHING OR
PERFORMANCE OF THE WORK OR ANY DUTY OR AUTHORITY TO UNDERTAKE RESPONSIBILITIES
CONTRARY TO THE PROVISIONS OF THE CONTRACT DOCUMENTS.
2. CONTRACT DOCUMENTS INCLUDE, BUT ARE NOT LIMITED TO, THE STRUCTURAL DOCUMENTS
(DRAWINGS AND SPECIFICATIONS), BUT DO NOT INCLUDE SHOP DRAWINGS, VENDOR DRAWINGS, OR
MATERIAL PREPARED AND SUBMITTED BY THE CONTRACTOR.
3. REFERENCE TO STANDARD SPECIFICATIONS OF ANY TECHNICAL SOCIETY, ORGANIZATION, OR ASSOCIATION OR TO CODES OF LOCAL OR STATE AUTHORITIES, SHALL MEAN THE LATEST STANDARD, CODE, SPECIFICATION OR TENTATIVE SPECIFICATION ADOPTED AT THE DATE OF TAKING BIDS, UNLESS
SPECIFICALLY STATED OTHERWISE.
4. CONTRACT DOCUMENTS SHALL GOVERN IN THE EVENT OF A CONFLICT WITH THE CODE OF PRACTICE OR SPECIFICATIONS OF ACI, PCI, AISC, SJI OR OTHER STANDARDS. WHERE A CONFLICT OCCURS
WITHIN THE CONTRACT DOCUMENTS, THE STRICTEST REQUIREMENT SHALL GOVERN.
5. MATERIAL, WORKMANSHIP, AND DESIGN SHALL CONFORM TO THE REFERENCED BUILDING CODE.
6. CONTRACTOR SHALL COORDINATE THE STRUCTURAL DOCUMENTS WITH THE ARCHITECTURAL,
MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL DOCUMENTS. DESIGN PROFESSIONAL SHALL BE NOTIFIED OF ANY DISCREPANCY OR OMISSION. FOR DIMENSIONS NOT SHOWN ON THE STRUCTURAL
DRAWINGS SEE THE ARCHITECTURAL DRAWINGS.
7. CONTRACTOR SHALL VERIFY EXISTING DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE
STARTING WORK. DESIGN PROFESSIONAL SHALL BE NOTIFIED OF ANY DISCREPANCY.
8. CONTRACTOR SHALL VERIFY THE STRUCTURALLY SUPPORTED MECHANICAL EQUIPMENT WEIGHTS, OPENING SIZES AND LOCATIONS IDENTIFIED ON THE STRUCTURAL DRAWINGS WITH ARCHITECTURAL
AND MECHANICAL DRAWINGS.
9. CONTRACTOR SHALL VERIFY THAT MISCELLANEOUS FRAMING SHOWN ON THE STRUCTURAL
DRAWINGS FOR MECHANICAL EQUIPMENT, OWNER-FURNISHED ITEMS, PARTITIONS, ETC. IS
CONSISTENT WITH THE REQUIREMENTS OF SUCH ITEMS.
10. CONTRACTOR HAS SOLE RESPONSIBILITY FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND
PROCEDURES OF CONSTRUCTION.
11. THE STRUCTURE IS STABLE ONLY IN ITS COMPLETED FORM. TEMPORARY SUPPORTS REQUIRED FOR STABILITY DURING ALL INTERMEDIATE STAGES OF CONSTRUCTION SHALL BE DESIGNED, FURNISHED, AND INSTALLED BY THE CONTRACTOR.
12. CONTRACTOR HAS SOLE RESPONSIBILITY TO COMPLY WITH ALL OSHA REGULATIONS.
13. ELECTRONIC DRAWING FILES WILL NOT BE PROVIDED TO THE CONTRACTOR. REPRODUCTION OF
STRUCTURAL DRAWINGS FOR SHOP DRAWINGS IS NOT PERMITTED.
14. REVIEW OF SUBMITTALS OR SHOP DRAWINGS BY THE DESIGN PROFESSIONAL DOES NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW AND CHECK ALL SUBMITTALS AND SHOP
DRAWINGS BEFORE SUBMITTING TO THE DESIGN PROFESSIONAL. CONTRACTOR REMAINS SOLELY
RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP
DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE
CONTRACT DOCUMENTS.
15. DETAILS LABELED "TYPICAL" ON THE STRUCTURAL DRAWINGS APPLY TO ALL SITUATIONS OCCURRING
ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THE TYPICAL DETAILS UNLESS THOSE
LOCATIONS ARE SPECIFICALLY DETAILED OTHERWISE.
16. STRUCTURAL DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR THE DESIGN OF CURTAIN
WALL/WINDOW WALL SYSTEMS, COLD-FORMED METAL FRAMING, OR OTHER SYSTEMS NOT SHOWN IN THE STRUCTURAL DOCUMENTS. SUCH SYSTEMS SHALL BE DESIGNED, FURNISHED, AND INSTALLED AS
REQUIRED BY OTHER PORTIONS OF THE CONTRACT DOCUMENTS.
17. SUBMITTALS
17.1 SUBMITTALS BY THE CONTRACTOR ARE NOT A PART OF THE CONTRACT DOCUMENTS. PRIOR
TO THE INITIAL SUBMITTAL, CONTRACTOR SHALL SUBMIT TO THE DESIGN PROFESSIONAL A
SCHEDULE OF SUBMITTED INFORMATION.
17.2 SUBMITTALS SHALL BE ACCOMPANIED BY A TRANSMITTAL LETTER WITH THE FOLLOWING
INFORMATION:
• PROJECT NAME
• CONTRACTOR'S NAME
• DATE SUBMITTED
• DESCRIPTION OF ITEMS SUBMITTED. IDENTIFY WORK AND PRODUCT BY SPECIFICATION
SECTION
• NUMBER OF DRAWINGS AND OTHER PERTINENT DATA.
17.3 CONTRACTOR SHALL DIRECT SPECIFIC ATTENTION ON THE SUBMITTAL TO ANY DEVIATION
FROM THE CONTRACT DOCUMENTS. CONTRACTOR SHALL STAMP AND SIGN EACH SHEET OF
SHOP DRAWINGS AND PRODUCT DATA, AND SIGN OR INITIAL EACH SAMPLE TO CERTIFY
COMPLIANCE WITH REQUIREMENTS OF CONTRACT DOCUMENTS. SUBMITTALS RECEIVED
WITHOUT THE CONTRACTOR'S STAMP OF REVIEW WILL BE RETURNED TO THE CONTRACTOR
FOR REVIEW AND RESUBMITTAL.
17.4 WORK REQUIRING SHOP DRAWINGS, WHETHER CALLED FOR BY THE CONTRACT DOCUMENTS
OR REQUESTED BY THE CONTRACTOR, SHALL NOT COMMENCE UNTIL THE SUBMISSION HAS
BEEN REVIEWED BY THE DESIGN PROFESSIONAL. WORK MAY COMMENCE IF THE CONTRACTOR
VERIFIES THE ACCURACY OF THE DESIGN PROFESSIONAL'S CORRECTIONS AND NOTATIONS
AND COMPLIES WITH THEM WITHOUT EXCEPTION AND WITHOUT REQUESTING CHANGE IN
CONTRACT SUM OR CONTRACT TIME AT COPY OF THE MARKED STRUCTURAL SHOP DRAWINGS
WITH THE DESIGN ROFESSIONAL'S REVIEW STAMP IS TO BE MAINTAINED AT THE JOB SITE.
GENERAL
1. STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE FOLLOWING:
• INTERNATIONAL BUILDING CODE, 2012 EDITION WITH GEORGIA AMENDMENTS.
2. GRAVITY LOADS
2.1 UNIFORM FLOOR LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
• GENERAL AREAS 100 PSF
2.2 UNIFORM ROOF LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
• ROOF 20 PSF
• GROUND SNOW LOAD, Pg 10 PSF
• SNOW EXPOSURE FACTOR, Ce = 0.9
• SNOW LOAD IMPORTANCE FACTOR, I = 1.0
• THERMAL FACTOR, Ct = 1.0
PONDING AND DRIFT EFFECTS HAVE BEEN INCLUDED IN THE DESIGN.
2.3 DEAD LOADS (IN ADDITION TO STRUCTURE SELF-WEIGHT):
ROOF:
• ROOFING 5 PSF
• MISCELLANEOUS 5 PSF
CODE/DESIGN CRITERIA
3. WIND LOADS:
• ULTIMATE DESIGN WIND SPEED, VULT = 115 MPH
• NOMINAL DESIGN WIND SPEED, VASD = 89 MPH
• RISK CATEGORY: II
• EXPOSURE B
SEE COMPONENT AND CLADDING DESIGN WIND PRESSURE DIAGRAM
4. EARTHQUAKE LOADS:
• RISK CATEGORY: II
• SEISMIC IMPORTANCE FACTOR: I = 1.0
• SHORT PERIOD MAPPED SPECTRAL RESPONSE COEFFICIENT, SS = 0.246
• 1 SECOND PERIOD MAPPED SPECTRAL RESPONSE COEFFICIENT, S1 = 0.101
• SITE CLASS D
• SHORT PERIOD DESIGN SPECTRAL RESPONSE COEFFICIENT, SDS = 0.262
• 1 SECOND PERIOD DESIGN SPECTRAL RESPONSE COEFFICIENT, SD1 = 0.162
• SEISMIC DESIGN CATEGORY: C
• BASIC SEISMIC-FORCE RESISTING SYSTEM: WOOD CANTILEVERED COLUMNS
• DESIGN BASE SHEAR: 23 KIPS
• SEISMIC RESPONSE COEFFICIENT, CS = 0.174
• RESPONSE MODIFICATION FACTOR, R = 1.5
• ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE
5. UNLESS NOTED OTHERWISE CALCULATED INDIVIDUAL MEMBER DEFLECTIONS (IN INCHES) DO NOT
EXCEED THE FOLLOWING:
DEAD LOAD LIVE LOAD DEAD + LIVE LOAD
ROOF MEMBERS: L/360 L/360 L/240
• WHERE, L = SPAN LENGTH (IN INCHES) BETWEEN SUPPORTS. (FOR CANTILEVERS, L IS
TWICE THE LENGTH OF THE CANTILEVER.) NOTE THAT THE TOTAL MAXIMUM
CALCULATED FLOOR SYSTEM DEFECTION WILL BE THE SUM OF THE DEFLECTIONS OF
THE SUPPORTED ELEMENTS IN A BAY.
• THE CALCULATED DEFLECTION FOR INDIVIDUAL MEMBERS SUPPORTING MASONRY DO
NOT EXCEED L/600 FOR DESIGN LOADS APPLIED AFTER THE INSTALLATION OF THE
MASONRY.
6. SPECIAL INSPECTIONS:
6.1 THE STRUCTURAL TESTING/INSPECTION AGENCY, SEE SPECIFICATION SECTION 014525, WILL
PERFORM SPECIAL INSPECTIONS AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE.
MATERIALS AND WORK TO BE INSPECTED INCLUDE WOOD AND CONCRETE CONSTRUCTION.
SEE SPECIFICATION SECTIONS 014525 FOR A COMPLETE LIST OF WORK REQUIRING SPECIAL
INSPECTIONS.
6.2 SPECIAL INSPECTION AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE ARE REQUIRED
FOR STRUCTURAL COMPONENTS AND ASSEMBLIES WHICH ARE NOT FABRICATED AT THE
CONSTRUCTION JOB SITE INCLUDING BUT NOT LIMITED TO ROOF TRUSSES AND JOISTS OF
WOOD MATERIALS.
6.3 SPECIAL INSPECTION AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE MAY BE WAIVED
FOR ITEMS WHICH ARE PRODUCED ON THE PREMISES OF A FABRICATOR REGISTERED AND
APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. APPROVAL SHALL BE
BASED UPON REVIEW OF THE FABRICATOR'S WRITTEN PROCEDURAL AND QUALITY CONTROL
MANUALS AND BY PERIODIC AUDITING OF FABRICATION PRACTICES BY AN APPROVED SPECIAL
INSPECTION AGENCY. THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF
COMPLIANCE TO THE CHIEF COMMERCIAL BUILDING INSPECTOR OR HIS DESIGNEE WHICH
STATES THAT THE FABRICATION WORK WAS PERFORMED IN ACCORDANCE WITH THE
APPROVED CONSTRUCTION DOCUMENTS.
6.4 THE PROJECT OWNER WILL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PERFORM
INSPECTIONS AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE DURING CONSTRUCTION
OF THE PROJECT. DOCUMENTATION THAT SUMMARIZES THE QUALIFICATION AND
CREDENTIALS OF EACH SPECIAL INSPECTOR AND DEMONSTRATES COMPETENCE FOR
INSPECTION OF EACH PARTICULAR TYPE OF CONSTRUCTION REQUIRING SPECIAL INSPECTION
SHALL BE SUBMITTED TO THE CHIEF COMMERCIAL BUILDING INSPECTOR OR HIS DESIGNEE
FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION.
6.5 APPROVED SPECIAL INSPECTORS SHALL FURNISH INSPECTION REPORTS TO THE CHIEF
COMMERCIAL BUILDING INSPECTOR OR HIS DESIGNEE AND TO THE DESIGN PROFESSIONAL
WHICH INDICATE THAT THE WORK INSPECTED WAS DONE IN CONFORMANCE WITH THE
APPROVED CONSTRUCTION DOCUMENTS. A FINAL REPORT WHICH DOCUMENTS THE RESULTS
OF THE SPECIAL INSPECTIONS PERFORMED INCLUDING CORRECTION OF ANY DISCREPANCIES
IDENTIFIED DURING INSPECTION SHALL BE SUBMITTED PERIODICALLY AT A FREQUENCY
APPROVED BY CHIEF COMMERCIAL BUILDING INSPECTOR PRIOR TO CONSTRUCTION.
7. NO PROVISIONS HAVE BEEN MADE FOR FUTURE HORIZONTAL OR VERTICAL EXPANSION.
1. FOUNDATION DESIGN IS BASED ON THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT
PREPARED BY GEO HYDRO ENGINEERS, PROJECT NUMBER 180267.20 DATED APRIL 3, 2018. DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR SUBSURFACE CONDITIONS ENCOUNTERED IN THE FIELD
DIFFERENT TO THOSE ASSUMED FOR DESIGN.
2. ALL FOUNDATIONS SHALL BE INSTALLED UNDER THE GUIDANCE OF A REGISTERED PROFESSIONAL
GEOTECHNICAL ENGINEER IN THE PROJECT STATE. THE GEOTECHNICAL ENGINEER SHALL GIVE
CONSIDERATION TO THE TYPE OF BUILDING AND FOUNDATION LOADS INVOLVED AS WELL AS THE
REQUIREMENTS OF THESE DOCUMENTS. DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR
SUBSURFACE CONDITIONS ENCOUNTERED IN THE FIELD DIFFERENT TO THOSE ASSUMED FOR
DESIGN.
3. STRUCTURAL TESTING/INSPECTION AGENCY SHALL CERTIFY THE BEARING MEDIUM.
4. INDIVIDUAL SPREAD FOOTINGS AND CONTINUOUS FOOTINGS SHALL BEAR ON SOIL CAPABLE OF
SUPPORTING 3000 PSF.
4.1 NO FOOTINGS SHALL BEAR ON ROCK. UNDERCUT ROCK A MINIMUM OF 2 FEET BELOW BOTTOM
OF FOOTING AND REPLACE WITH STRUCTURAL FILL.
5. PROOF ROLL BUILDING AREAS WITH TWO COMPLETE COVERAGES OF A LOADED DUMP-TRUCK OR
SCRAPER. REPLACE SOFT AREAS WITH COMPACTED STRUCTURAL FILL AS REQUIRED BY THE
SPECIFICATIONS.
6. STRUCTURAL FILL SHALL CONTAIN NO ORGANIC MATERIAL AND BE APPROVED BY A
GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. STRUCTURAL FILL UNDER SLABS AND WITHIN
10'-0" OF THE BUILDING FOOTPRINT SHALL BE PLACED IN LIFTS OF THICKNESS DETERMINED BY
THE INDEPENDENT TESTING AGENCY AND COMPACTED TO AT LEAST 95% OF ITS STANDARD
PROCTOR MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D698. THE TOP 12" SUB-BASE
UNDER SLABS ON GRADE SHALL BE COMPACTED TO AT LEAST 98% OF ITS STANDARD PROCTOR
MAXIMUM DRY DENSITY. ALL BACKFILL, COMPACTION AND PROOF ROLLING OPERATIONS SHALL
BE OBSERVED BY AN INDEPENDENT TESTING LABORATORY. STRUCTURAL FILL SOIL DENSITY
SHALL BE 120 PCF.
7. SLABS-ON-GRADE SHALL BE PLACED ON A 4" GRANULAR BASE, COMPACTED TO 98% OF ITS
STANDARD PROCTOR MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D698, AND COVERED
WITH A 10 MIL CONTINUOUSLY SEALED VAPOR BARRIER. THE BASE FOR SLABS-ON-GRADE SHALL
BE INSPECTED BY A GEOTECHNICAL ENGINEER PRIOR TO EACH PLACEMENT OF CONCRETE.
8. FOOTINGS SHALL BE CENTERED ABOUT COLUMN LINES UNLESS NOTED OTHERWISE.
9. ALL FOOTINGS AND TURN DOWN SLAB EDGES SHALL PENETRATE TO A MINIMUM DEPTH OF 18"
BELOW FINISHED GRADE.
FOUNDATION
1. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE.
2. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064 AND HAVE MINIMUM SIDE AND END LAPS
OF 8".
3. SUBMIT SHOP DRAWINGS WHICH ADEQUATELY DEPICT THE REINFORCING BAR SIZES AND
PLACEMENT. WRITTEN DESCRIPTION OF REINFORCEMENT WITHOUT ADEQUATE SECTIONS,
ELEVATIONS, AND DETAILS IS NOT ACCEPTABLE.
4. SPLICES SHALL BE CLASS B IN ACCORDANCE WITH ACI 318, UNLESS NOTED OTHERWISE.
REINFORCEMENT SHALL BE SPLICED ONLY AT LOCATIONS SHOWN OR NOTED IN THE STRUCTURAL
DOCUMENTS, EXCEPT REINFORCEMENT MARKED "CONTINUOUS" CAN BE SPLICED AT LOCATIONS
DETERMINED BY CONTRACTOR. SPLICES AT OTHER LOCATIONS SHALL BE APPROVED IN WRITING
BY THE DESIGN PROFESSIONAL.
5. PROVIDE DOWELS FROM FOUNDATIONS THE SAME SIZE AND NUMBER AS THE VERTICAL WALL OR
COLUMN REINFORCING, UNLESS NOTED OTHERWISE.
6. PLACE REINFORCEMENT AS FOLLOWS, UNLESS NOTED OTHERWISE:
6.1 CONCRETE REINFORCEMENT COVER
EXPOSED TO EARTH OR WEATHER:
• UNFORMED CAST AGAINST EARTH 3” CLEAR
• FORMED #6 AND LARGER 2” CLEAR
• FORMED #5 AND SMALLER 1-1/2” CLEAR
NOT EXPOSED TO EARTH OR WEATHER:
• WALLS 1" CLEAR
• SLABS 3/4" CLEAR
7. REINFORCING STEEL DESIGNATED CONTINUOUS SHALL BE LAPPED AS FOLLOWS:
• CONCRETE REINFORCEMENT: CLASS B TENSION LAP
8. ADHESIVE FOR REINFORCING DOWELS IN EXISTING CONCRETE SHALL CONFORM TO ASTM
C881-02, TYPE IV, GRADE 3, CLASS A, B, & C EXCEPT GEL TIMES AND EPOXY CONTENT. ADHESIVE
SHALL CONSIST OF A TWO COMPONENT ADHESIVE SYSTEM CONTAINED IN SIDE BY SIDE
PACKAGING CONNECTED TO A MIXING NOZZLE WHICH THOROUGHLY MIXES THE COMPONENTS AS
IT IS INJECTED INTO THE HOLE. ADHESIVE SHALL HAVE PASSED ICC EVALUATION SERVICES, INC
(ICC-ES) ACCEPTANCE CRITERIA 308 FOR LONG TERM CREEP. REINFORCING INSTALLED IN
CONCRETE THAT MAY BECOME CRACKED UNDER SERVICE LOADS SHALL BE EVALUATED BY ICC-
ES ACCEPTANCE CRITERIA 308 AND BE SPECIFICALLY APPROVED FOR USE IN CRACKED
CONCRETE. CONTACT DESIGN PROFESSIONAL FOR DETERMINATION OF CRACKED OR
UNCRACKED CONCRETE CONDITION UNLESS CONDITION IS NOTED ON THE DRAWINGS. INSTALL IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. MINIMUM EMBEDMENT LENGTH
SHALL BE 12 BAR DIAMETERS, UNLESS NOTED OTHERWISE.
9. ALL DOWELS AND TERMINATING BARS SHALL HAVE A STANDARD 90 DEGREE HOOK.
10. ALL HORIZONTAL REINFORCING SHALL BE CONTINUOUS THROUGH CONTROL AND/OR
CONSTRUCTION JOINTS AND AROUND CORNERS.
REINFORCEMENT
1. CONCRETE WORK SHALL CONFORM TO ACI 318 AND CRSI STANDARDS.
2. CONCRETE SHALL HAVE THE FOLLOWING MINIMUM SPECIFIED 28-DAY COMPRESSIVE STRENGTH:
2.1 NORMAL WEIGHT STRUCTURAL CONCRETE:
• FOOTINGS 3000 PSI
• SLABS-ON-GRADE 4500 PSI
3. PIPES OR DUCTS SHALL NOT EXCEED ONE-THIRD THE SLAB OR WALL THICKNESS INCLUDING
CROSSING UNLESS SPECIFICALLY DETAILED IN THE STRUCTURAL DOCUMENTS. ALL PIPES AND
DUCTS SHALL BE PLACED IN THE MIDDLE THIRD OF THE SLAB OR WALL THICKNESS UNLESS
SPECIFICALLY DETAILED OTHERWISE IN THE STRUCTURAL DOCUMENTS. SEE MECHANICAL AND
ELECTRICAL DRAWINGS FOR LOCATION OF SLEEVES, ACCESSORIES, ETC.
4. REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES, ORNAMENTS, CLIPS OR GROUNDS
REQUIRED TO BE ENCASED IN CONCRETE AND FOR LOCATION OF FLOOR FINISHES AND SLAB
DEPRESSIONS.
5. CONSTRUCTION JOINT LOCATIONS SHALL BE APPROVED BY THE DESIGN PROFESSIONAL. NO
HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED EXCEPT THOSE SHOWN ON THE
STRUCTURAL DRAWINGS.
6. DEFECTIVE AREAS IN CONCRETE INCLUDING, BUT NOT LIMITED TO, HONEY-COMBING, SPALLS, AND CRACKS WITH WIDTHS EXCEEDING 0.016 INCH SHALL BE REPAIRED. EXTENT OF DEFECTIVE AREA
TO BE DETERMINED BY THE DESIGN PROFESSIONAL.
CAST-IN-PLACE CONCRETE
1. WOOD FRAMING SHALL BE SOUTHERN PINE, NO. 1 K.D. (15% MAX. MOISTURE CONTENT) OR
EQUIVALENT. MINIMUM ALLOWABLE BENDING STRESS SHALL BE PER NDS (2013 ADDENDUM).
2. WOOD TRUSSES SHALL BE CAPABLE OF SUPPORTING THE SUPERIMPOSED LOADS AS GIVEN IN THE
CONTRACT DOCUMENTS.
3. DESIGN OF WOOD TRUSSES SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. SUBMIT
SHOP DRAWINGS, DESIGN LOAD DATA, AND SUPPORT REACTIONS SEALED BY AN ENGINEER
LICENSED IN THE PROJECT STATE. REVIEW OF SHOP DRAWINGS SHALL BE FOR CONFORMANCE
WITH THE CONTRACT DOCUMENTS WITH REGARD TO TRUSS CONFIGURATION, AND THE
CONTRACTOR'S INTERPRETATION OF DESIGN LOADS AND DETAILS. SUCH REVIEW SHALL NOT
RELIEVE THE CONTRACTOR OF THE FULL RESPONSIBILITY FOR THE DESIGN OF THE TRUSSES OR
TRUSS CONNECTIONS NOT SPECIFICALLY DETAILED IN THE CONTRACT DOCUMENTS.
4.1 ALL HARDWARE REQUIRED FOR CONNECTIONS BETWEEN PRE-ENGINEERED TRUSSES SHALL BE
DESIGNED BY AND SPECIFIED BY THE TRUSS DESIGN ENGINEER.
4.2 ALL PRE-ENGINEERED METAL PLATE CONNECTED WOOD TRUSSES SHALL BE BRACED IN
ACCORDANCE WITH TRUSS PLATE INSTITUTE'S "HANDLING, INSTALLING, AND BRACING METAL
PLATE CONNECTED WOOD TRUSSES, HIB-91" AND "BUILDING COMPONENT SAFETY INFORMATION
BOOKLET, BCSA 1-03" AND RELATED SHEETS.
4.3 ALL PRE-ENGINEERED TRUSS SHOP DRAWINGS SHALL BE AVAILABLE ON THE JOB SITE DURING THE TIMES OF INSPECTION AND SHALL BEAR CLEAR INDICATION THEY HAVE BEEN REVIEWED BY
THE PROJECT DESIGN PROFESSIONAL OF RECORD.
4.4 TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION
FOR WOOD CONSTRUCTION AND THE DESIGN SPECIFICATION FOR METAL PLATE CONNECTED
WOOD TRUSSES PUBLISHED BY THE TRUSS JOIST INSTITUTE, LATEST EDITION FOR THE
FOLLOWING LOADS. CONNECTIONS BETWEEN TRUSSES SHALL BE DESIGNED AND SPECIFIED BY
THE TRUSS ENGINEER. TRUSSES SHALL HAVE A MINIMUM NOMINAL BEARING LENGTH OF 4
INCHES (3 1/2" ACTUAL). CONCENTRATED MECHANICAL ELECTRICAL LOADS: SEE PLANS. TOP
AND BOTTOM CHORD OF TRUSSES SHALL BE AS SHOWN IN THE CONSTRUCTION DOCUMENTS.
4.5 TRUSS LOADING (IN ADDITION TO SELF WEIGHT). SEE TRUSS DIAGRAMS FOR ADDITIONAL
INFORMATION.
DEAD LOAD: LIVE LOAD:
TOP CHORD: 20 PSF 20 PSF
BOTTOM CHORD: 5 PSF -
4. ERECTION AND TEMPORARY BRACING OF PREFABRICATED WOOD TRUSSES SHALL BE IN
CONFORMANCE WITH THE RECOMMENDATIONS OF THE TRUSS MANUFACTURER AND THE TRUSS
PLATE INSTITUTE'S "BRACING WOOD TRUSSES: COMMENTARY AND RECOMMENDATIONS".
WOOD
6. CONNECTIONS FOR STRUCTURAL TIMBER SHALL BE GALVANIZED CONNECTORS.
7. WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE FOUNDATION GRADE PRESSURE-
TREATED SOUTHERN PINE. USE GALVANIZED NAILS IN PRESSURE-TREATED WOOD.
8. PROVIDE DOUBLE TOP PLATE LAPPED AT CORNERS AND AT SPLICES (4' SPLICE). SUPPORT ENDS OF
LAPS DIRECTLY OVER A VERTICAL LOAD BEARING STUD.
9. ROOF AND WALL SHEATHING SHALL BE PROVIDED IN ACCORDANCE WITH THE RECOMMENDATIONS
OF THE AMERICAN PLYWOOD ASSOCIATION (APA). THE MINIMUM THICKNESSES WHICH FOLLOW
SHALL BE INCREASED AS REQUIRED TO SATISFY ARCHITECTURAL REQUIREMENTS.
9.1 PLYWOOD DIAPHRAGMS SHALL BE EITHER STRUCTURAL I OR II SOUTHERN PINE PLYWOOD
WITH THICKNESS AS NOTED IN THE STRUCTURAL DOCUMENTS. PLYWOOD SHALL CONFORM TO
THE REQUIREMENTS OF THE BUILDING CODE.
9.2 ROOF SHEATHING SHALL BE APA RATED SHEATHING, EXPOSURE I, 48"x96", 3/4" 32/16
PLYWOOD SHEATHING. SHEATHING SHALL BE TONGUE AND GROOVE OR BE INSTALLED WITH
PANEL CLIPS IN ACCORDANCE WITH APA RECOMMENDATIONS. WHERE ALLOWABLE SPANS ARE
EXCEEDED AT ROOF SLOPE TRANSITIONS, PROVIDE SPECIALLY DESIGNED SUPPLEMENTAL
MEMBERS AS REQUIRED. SHEATHING SHALL BE INSTALLED WITH THE LONG EDGE ACROSS A
MINIMUM OF THREE SUPPORTING MEMBERS. SUPPORT AND STAGGER EDGES OF SHEATHING
PARALLEL TO SUPPORTING MEMBER. PROVIDE CONTINUOUS BLOCKING AT PERIMETER OF
EACH DIAPHRAGM PLANE (INCLUDING ROOF SLOPE TRANSITIONS) AND AROUND OPENINGS.
FASTEN SHEATHING WITH 8d NAILS AT 6" O.C. AT SUPPORTED EDGES UNO AND AT 12" O.C. AT INTERMEDIATE SUPPORTS. AN 1/8" GAP SHALL BE LEFT BETWEEN ADJACENT PANELS. PROTECT
EDGES AGAINST EXPOSURE TO WEATHER OR USE EXTERIOR GRADE SHEATHING. COVER
SHEATHING AS SOON AS POSSIBLE WITH ROOFING FELT OR SHINGLE UNDERLAYMENT FOR
PROTECTION AGAINST EXCESSIVE MOISTURE PRIOR TO ROOFING INSTALLATION.
9.3 WALL SHEATHING SHALL BE APA RATED SHEATHING, EXPOSURE I, 48"x96", 15/32" 32/16
PLYWOOD SHEATHING WITH CONTINUOUSLY SUPPORTED EDGES. AN 1/8" GAP SHALL BE LEFT
BETWEEN ADJACENT PANELS. PROVIDE ONE LAYER ON ONE SIDE OF WALL UNLESS INDICATED
ON PLAN TO PROVIDE ON LAYER ON EACH SIDE OF WALL.
9.4 FASTEN WALL SHEATHING WITH 8d NAILS @ 6" O.C. AT PANEL EDGES AND @ 12" O.C. AT
INTERMEDIATE SUPPORTS. SEE SCHEDULE FOR SHEAR WALL SHEATHING FASTENERS.
10. WOOD ROOF DECKING SHALL BE SELECT GRADE 2x6 TONGUE AND GROOVE DECKING. FASTEN TO TIMBER TRUSSES WITH THREE (3) 16d NAILS AT EACH BOARD END AND (2) 16d NAILS AT EACH
INTERMEDIATE SUPPORT.
11. FASTENING SCHEDULE SHALL BE IN ACCORDANCE WITH TABLE 2304.9.1 IN THE INTERNATIONAL
BUILDING CODE, 2012 EDITION, UNLESS OTHERWISE SPECIFIED IN THE CONSTRUCTION
DOCUMENTS.
12. PROVIDE WOOD BLOCKING AT 4'-0" O.C. AT WALL STUDS.
Nelco Architecture, Inc.
a licensed affiliate of Nelson Worldwide, LLC.
DESIGNING ARCHITECT
ARCHITECT OF RECORD
RELEASED FOR CONSTRUCTION
COPYRIGHT AND REPRODUCTION NOTICE
© 2018 Wakefield Beasley & Associates Architects, Inc.
These drawings are protected by the copyright laws of the
United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of WBA.
F
IL
E N
A M
E
S H
E E
T N
A M
E
SHEET NUMBER
DATE
SHEET TITLE
DAWSON
COUNTY
PAVILION
Print Record
PROJECT NUMBER
Revisions
No. Date Description
2019-01-14 SCHEMATIC DESIGN PACKAGE
2019-02-19 CONSTRUCTION DOCUMENTS 100%
/1
/2
:3 :4
A
M C
U s e rs
\U s e r1
\D o c u m e n ts
\0 .1
.2
D a w s o n C o u n ty
P a v ili o n S
T R
U C
T in fo s h e a rs tr u c tu ra l.
c o m
.r v t
201 RECREATION RD
DAWSONVILLE, GA 30534
February 19, 2019
GENERAL NOTES
S0-01
G E
N E
R A
L N
O T
E
E T
N U
M B
E R
S
-0
P
R O
J E
C T
N A
M E
P
R O
J E
C T
N A
M
.4
' T Y
P
IC
A L
3'-0" TYP
ROOF PLAN COMPONENTS AND CLADDING ULTIMATE
WIND PRESSURE DIAGRAM
= -38 PSF/+38 PSF
= -58 PSF/+57 PSF
= -58 PSF/+57 PSF
NOTE: WIND PRESSURE BASED ON 50 SQUARE FOOT AREA.
NEGATIVE INDICATES PRESSURE AWAY FROM SURFACE.
WALL ELEVATION COMPONENTS AND CLADDING ULTIMATE
WIND PRESSURE DIAGRAM
= -23 PSF/+21 PSF
= -27 PSF/+21 PSF
NOTE: WIND PRESSURE BASED ON 25 SQUARE FOOT AREA.
NEGATIVE INDICATES PRESSURE AWAY FROM SURFACE.
Nelco Architecture, Inc.
a licensed affiliate of Nelson Worldwide, LLC.
DESIGNING ARCHITECT
ARCHITECT OF RECORD
RELEASED FOR CONSTRUCTION
COPYRIGHT AND REPRODUCTION NOTICE
© 2018 Wakefield Beasley & Associates Architects, Inc.
These drawings are protected by the copyright laws of the
United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of WBA.
F
IL
E N
A M
E
S H
E E
T N
A M
E
SHEET NUMBER
DATE
SHEET TITLE
DAWSON
COUNTY
PAVILION
Print Record
PROJECT NUMBER
Revisions
No. Date Description
2019-01-14 SCHEMATIC DESIGN PACKAGE
2019-02-19 CONSTRUCTION DOCUMENTS 100%
/1
/2
:3 :4
A
M C
U s e rs
\U s e r1
\D o c u m e n ts
\0 .1
.2
D a w s o n C o u n ty
P a v ili o n S
T R
U C
T in fo s h e a rs tr u c tu ra l.
c o m
.r v t
201 RECREATION RD
DAWSONVILLE, GA 30534
February 19, 2019
COMPONENTS AND
CLADDING
S0-02
C O
M P
O N
E N
T S
A N
D C
L A
D D
IN
E
E T
N U
M B
E R
S
-0
P
R O
J E
C T
N A
M E
P
R O
J E
C T
N A
M
A B C D E F G
15'-0" 15'-0"
1'-9 1/8"
10'-11 3/8" 7'-3 1/2" 7'-3 1/2" 10'-11 3/8"
1'-9 1/8"
15'-0" 15'-0"
/8
/8
/8
8x8 P O S T
F4.0
8x8 P O S T
F4.0
8x8 P O S T
F4.0
8x8 P O S T
F4.0
(2) 6x10 P O
STS
F4.0
8x8 P O S
TS
F4.0
8x8 P O S T
F4.0
8x
PO
S T
F4.
0 8x
PO
S T
F4.
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
(2) 6x10 P O
STS
F4.0
S3-01
TYP
S3-01
TYP
S3-01
C.J. TYP
SEE NOTE 5
5" SLAB ON GRADE
SEE NOTE 4
S3-01
S3-01
S3-01
S3-01
SEE NOTE 6
S3-01
S3-01
2x6 STUDS @ 16" O.C.
2x6 STUDS @ 16" O.C.
2x8 STUDS @ 16" O.C.
2x8 STUDS @ 16" O.C.
6x6 P O
ST
6x6 P O
ST
6x6 P O
ST
6x6 P O
ST
6x
PO
ST
6x
PO
ST
6x
PO
ST6x6 PO
ST
S3-01
SW1
SW1
S W
S W
C.1 C.2 D.1 D.2
3.1
S3-01
TYP
NOTES:
1. SEE S0-01 FOR STRUCTURAL GENERAL NOTES.
2. SEE ARCH FOR ADDITIONAL INFORMATION AND DIMENSIONS.
3. Fx INDICATES COLUMN FOOTING. SEE 9/S3-01. T/FTG = -1'-6" UNO, BASED ON T/SLAB REFERENCE ELEVATION = 0'-0".
4. PROVIDE 5" SLAB ON GRADE REINFORCED WITH WWF 6x6 W2.1xW2.1 ON 4" GRANULAR BASE.
5. C.J. INDICATES SLAB CONTROL JOINT. SEE 3/S3-01 AND GENERAL NOTES FOR ADDITIONAL INFORMATION.
6. PROVIDE REINFORCEMENT AT RE-ENTRANT CORNERS, SEE 6/S3-01.
7. SWx INDICATES SHEAR WALL, SEE 7/S6-02.
Nelco Architecture, Inc.
a licensed affiliate of Nelson Worldwide, LLC.
DESIGNING ARCHITECT
ARCHITECT OF RECORD
RELEASED FOR CONSTRUCTION
COPYRIGHT AND REPRODUCTION NOTICE
© 2018 Wakefield Beasley & Associates Architects, Inc.
These drawings are protected by the copyright laws of the
United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of WBA.
F
IL
E N
A M
E
S H
E E
T N
A M
E
SHEET NUMBER
DATE
SHEET TITLE
DAWSON
COUNTY
PAVILION
Print Record
PROJECT NUMBER
Revisions
No. Date Description
2019-01-14 SCHEMATIC DESIGN PACKAGE
2019-02-19 CONSTRUCTION DOCUMENTS 100%
/1
/2
:3 :4
A
M C
U s e rs
\U s e r1
\D o c u m e n ts
\0 .1
.2
D a w s o n C o u n ty
P a v ili o n S
T R
U C
T in fo s h e a rs tr u c tu ra l.
c o m
.r v t
201 RECREATION RD
DAWSONVILLE, GA 30534
February 19, 2019
FOUNDATION PLAN
S1-10
F O
U N
D A
T
IO
N P
L A
N
S
H E
E T
N U
M B
E R
S
-1
P
R O
J E
C T
N A
M E
P
R O
J E
C T
N A
M E
1816000.000 3/16" = 1'-0"S1-10
1 FOUNDATION PLAN
A B C D E F G
T2
T3
T3
T2 SIM
T
T S
IM
T
T S
IM
T
T
S6-01
TYP
S6-01
TYP
S6-01
TYP
S6-01
TYP
S6-01
S6-01
S6-01
S6-01
6x10 PURLINS @ 4'-0" O.C.
6x10 PURLINS @ 4'-0" O.C.
6x10 PURLINS @ 4'-0" O.C.
6x10 PURLINS @ 4'-0" O.C.
T
6x10 PURLINS @ 4'-0" O.C.
6x10 PURLINS @ 4'-0" O.C.
x
R L
IN
O .C x
R L
IN
O .C x
R L
IN
O .C x
R L
IN
O .C
8x
8x14
8x148x x
8x10 (LO) 8x10 (LO) 8x10 (LO) 8x10 (LO)
8x10 (LO)8x10 (LO)
8x10 (LO) 8x10 (LO) 8x10 (LO) 8x10 (LO)
8x10 (LO) 8x10 (LO) 8x10 (LO) 8x10 (LO)
8x10 (LO) 8x10 (LO) x
L O x
L O x
L O
S6-01
TYP
S6-01
TYP
8x14 8x
8x
8x14
S6-02
S6-01
C.1 C.2 D.1 D.2
3.1
15'-0" 15'-0"
1'-9 1/8"
10'-11 3/8" 7'-3 1/2" 7'-3 1/2" 10'-11 3/8"
1'-9 1/8"
15'-0" 15'-0"
/8
/8
/8
NOTES:
1. SEE S0-01 FOR STRUCTURAL GENERAL NOTES.
2. SEE ARCH FOR ADDITIONAL INFORMATION AND DIMENSIONS.
3. INDICATES DIRECTIONAL SPAN OF 2x6 TONGUE AND GROOVE WOOD DECKING, SEE 3/S6-01 AND GENERAL NOTES.
4. Tx INDICATES PRE-ENGINEERED TIMBER TRUSS, SEE S6-03 FOR TRUSS PROFILES. TRUSS BEARING ELEVATION = 14'-0", UNO.
SEE GENERAL NOTES FOR ADDITIONAL INFORMATION.
5. BEAM BEARING ELEVATION AT "LO" = 14'-0", UNO.
Nelco Architecture, Inc.
a licensed affiliate of Nelson Worldwide, LLC.
DESIGNING ARCHITECT
ARCHITECT OF RECORD
RELEASED FOR CONSTRUCTION
COPYRIGHT AND REPRODUCTION NOTICE
© 2018 Wakefield Beasley & Associates Architects, Inc.
These drawings are protected by the copyright laws of the
United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of WBA.
F
IL
E N
A M
E
S H
E E
T N
A M
E
SHEET NUMBER
DATE
SHEET TITLE
DAWSON
COUNTY
PAVILION
Print Record
PROJECT NUMBER
Revisions
No. Date Description
2019-01-14 SCHEMATIC DESIGN PACKAGE
2019-02-19 CONSTRUCTION DOCUMENTS 100%
/1
/2
:3 :4
A
M C
U s e rs
\U s e r1
\D o c u m e n ts
\0 .1
.2
D a w s o n C o u n ty
P a v ili o n S
T R
U C
T in fo s h e a rs tr u c tu ra l.
c o m
.r v t
201 RECREATION RD
DAWSONVILLE, GA 30534
February 19, 2019
ROOF FRAMING PLAN
S1-70
R O
O F
F R
A M
IN
G
P L A
N
S
H E
E T
N U
M B
E R
S
-7
P
R O
J E
C T
N A
M E
P
R O
J E
C T
N A
M E
1816000.000 3/16" = 1'-0"S1-70
1 ROOF FRAMING PLAN
CONSTRUCTION JOINT
NOTE: SAW CUT OR DISCONTINUE REINF
AT CONTRACTION JT.
SLAB REINF IN TOP 1/3
OF SLAB
TOOLED JT
SLAB REINF IN TOP 1/3
OF SLAB
CONTRACTION JOINT
1/8" x 1/3 SLAB
DEPTH SAW CUT JT
2#5 CONT
WWF
FIN GR T/SLAB EL
8"
M
IN
SLAB ON GRADE,
SEE PLAN
20"x20" CONC PEDESTAL, SEE ARCH FOR FINISH
WRAP AT CANOPY DIMS
T/FTG EL
COLUMN BASE W/ 14000 MIN
GRAVITY LOAD CAPACITY &
6700LB MIN UPLIFT LOAD
CAPACITY , INSTALL PER MFR
REQUIREMENTS
SEE FOOTING
SCHEDULE FOR REINF
T/SLAB EL
CL FTG
4#6 DOWELS
6x10 POSTS, SEE PLAN
1/4" EXP JT MATERIAL
#3 TIES @ 12" O.C.
A A
5"
DOWNSPOUT,
SEE ARCH
WOOD POST,
SEE PLAN
4#6 DOWELS
20"x20" CONC
PEDESTAL
#3 TIES @
12" O.C.
20"x20" CONC PEDESTAL, SEE ARCH FOR FINISH
WRAP AT CANOPY DIMS
T/FTG EL
COLUMN BASE W/ 14000 MIN
GRAVITY LOAD CAPACITY &
6700LB MIN UPLIFT LOAD
CAPACITY , INSTALL PER
MFR REQUIREMENTS
SEE FOOTING
SCHEDULE FOR REINF
T/SLAB EL
CL FTG
4#6 DOWELS
8x8 POST, SEE PLAN
1/4" EXP JT MATERIAL
#3 TIES @ 12" O.C.
A A
WOOD POST,
SEE PLAN
4#6 DOWELS
20"x20" CONC
PEDESTAL
#3 TIES @
12" O.C.
T/FTG EL
COLUMN BASE W/ 14000 MIN
GRAVITY LOAD CAPACITY &
6700LB MIN UPLIFT LOAD
CAPACITY , INSTALL PER
MFR REQUIREMENTS
SEE FOOTING
SCHEDULE FOR REINF
T/SLAB EL
CL FTG
6#6 DOWELS
8x8 POST OR 6x8 POST, SEE PLAN
1/4" EXP JT MATERIAL
#3 TIES @ 12" O.C.
A A
WOOD POST,
SEE PLAN
6#6 DOWELS
20"x34" CONC
PEDESTAL
#3 TIES @
12" O.C.
2#5 x 4'-0" TOP
BLDG CORNER OR
CONSTRUCTION JT
3"
2"
2#5 CONT
WWF
FIN GR
T/SLAB EL
2'-7" @ BUMPOUT
8" @ SIM 8" 8"
M
IN
SLAB ON GRADE,
SEE PLAN
#4@12" O.C.
3'-0"
PT SILL PLATE W/ 1/2"
DIA ANCHOR BOLTS @
2'-0" O.C. AND WITHIN
12" OF ALL CORNERS
2x STUD WALL, SEE PLAN
PLYWOOD
SHEATHING
5#4 CONT
3#4 CONT @ SIM
#4@12" O.C.
ARCH
BUMPOUT3#4 CONT
WWF
T/SLAB EL
SLAB ON GRADE,
SEE PLAN
PT SILL PLATE W/ 5/8"
DIA ANCHOR BOLTS @
2'-0" O.C. AND WITHIN
12" OF ALL CORNERS
2x STUD WALL, SEE PLAN
PLYWOOD
SHEATHING
#4@12" O.C.
2'-0"
3#4 CONT
WWF
T/SLAB EL
SLAB ON GRADE,
SEE PLAN
WOOD POST,
SEE PLAN
#4@12" O.C.
2'-0"
COLUMN BASE W/ 14000 MIN
GRAVITY LOAD CAPACITY &
6700LB MIN UPLIFT LOAD
CAPACITY , INSTALL PER
MFR REQUIREMENTS
FOOTING SCHEDULE
MA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .