Addendum #1 for the City of Delta, Colorado's Directional Drilling project provides clarification and additional details for potential bidders on a municipal infrastructure improvement project. The addendum addresses various questions regarding utility work, including waterline installation and electrical conduit placement at multiple locations: Hartig Drive Alley, E 7th Street, West 5th Street, and Confluence Drive. The document outlines specific responsibilities for the contractor, such as calling in utility locates, and the city's provisions, including water availability, equipment storage, soil disposal, and bore pit filling. The project involves directional drilling for water lines ranging from 1" to 6" in length, with total base bid locations covering approximately 1,680 linear feet and optional alternate locations adding up to 2,000 linear feet.

The bid documents include a detailed Directional Drilling Bid Tab that breaks down location-specific requirements, including line sizes, lengths, number of pipes, materials (including Pure Core and HDPE SDR 13.5), and pressure testing specifications. The city has provided supplementary materials such as City Standards and Specifications, a Geotech report for Confluence Drive, a revised Bid Tab, and an Area Utilities Map. The addendum emphasizes that the information contained supersedes any previous documentation and must be acknowledged in submitted proposals. Soil conditions vary by location, with some areas described as having little to no rock and others consisting of Pit Run material, which may impact drilling complexity and equipment requirements.

View the file

Other files

File Type Posted
Directional Drilling IFB.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CITY OF DELTA, COLORADO

INVITATION FOR BID

DIRECTIONAL DRILLING

Addendum # 1 - June 30, 2025

QUESTIONS RECEIVED AND ANSWERS

1. Is the contractor responsible for any services on the waterlines?

Answer: The city will be responsible for all services.

2. Is the contractor responsible for calling in locates?

Answer: The contractor will be responsible for calling in utility locates; however, the City will provide a map showing the utilities in the area for which it has available data.

3. Will water be available for the contractor?

Answer: Water will be available through hydrants or the public water dispenser at no charge.

4. Will there be a designated area for the disposal of soil?

Answer: The city will provide a location for disposal at no charge.

5. Is there a designated area that the contractor can store vehicles and equipment related to the project?

Answer: The city will provide an area for equipment storage.

6. Who is responsible for filling in the bore pits?

Answer: The city will fill in all bore pits.

7. Will a trailer be provided for the electrical conduit and water line?

Answer: A city reel trailer will be provided.

8. Who is responsible for putting the pipe together?

Answer: The contractor will put together the Certalock pipe, and the city will do the tie-ins and fittings.

9. Who is responsible for disinfection?

Answer: The contractor will fill, and the city will inspect and flush.

10. Does the city have any insight into the soil material for the locations?

Answer:

Location 1 - when excavating in the past, the material would be suitable for standard tooling as the soil had little to no rock in it

Location 2 - would consist of Pit Run material going down 5th St., with the unknown of the material that is under Confluence Drive

Location 3 - would consist of Pit Run material

Location 4 - when excavating in the past, the material would be suitable for standard tooling as the soil had little to no rock in it.

CHANGES TO PROVIDED MATERIALS

1. City Standards and Specifications can be found at https://www.cityofdelta.net/publicworks-utilities/page/standards-specifications-details

2. Geotech report for Confluence Drive attached – Refer to page 3 #TH-22

3. Revised Bid Tab attached

4. Area Utilities Map

THIS ADDENDUM #1 TO THE ABOVE PROJECT.

INFORMATION CONTAINED IN ADDENDUM#1 SHALL SUPERSEDE ANY

INFORMATION PRESENTED IN THE RFP AND SHOULD BE ACKNOWLEDGED IN

THE PROPOSAL SUBMITTED BY RESPONDENTS.

END OF ADDENDUM #1

https://www.cityofdelta.net/publicworks-utilities/page/standards-specifications-details

Location # Location Line Size Length # of Pipes Material Purpose Pressure Testing Alternate Total Price

1 Hartig Dr Alley ‐ 7th to Cherry Lane 2" 680' Pure Core Water Line Yes No $

E 7th St between Hartig and Viente 2" 80' 1 HDPE SDR 13.5 Electric Conduit No No $

2 West 5th and Confluence 6" 600' DR18 C‐900 Certalok Water Line Yes No $

3 West 5th and Confluence 6" 800' DR18 C‐900 Certalok Water Line Yes Yes $

West side of E 5th and Confluence 2" 80' 3 HDPE SDR 13.5 Electric Conduit No No $

South side of E 5th and Confluence 2" 140' 4 HDPE SDR 13.5 Electric Conduit No No $

East side of E 5th and Confluence 2" 80' 3 HDPE SDR 13.5 Electric Conduit No No $

4 Trap Club Rd. (ALTERNATE) 1" 2000' Pure Core Water Line No Yes $

Potholing (ALTERNATE) Yes $ EACH POTHOLE

Total Base Bid Construction Cost $

Total Base Bid with Alternates Construction Cost $

Directional Drilling Bid Tab

© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TomTom map: Auto (Aerial) Mar 2022 - Jul 2022

Addendum 1
Geotech
42-Geotech (1)
43-Geotech (2)
44-Geotech (3)
45-Geotech (4)
46-Geotech (5)
47-Geotech (6)
48-Geotech (7)
49-Geotech (8)
Bid Tab - v3
5th Street
E 5th Pond
Truck route 4th and 5th
Utilities Maps
5th St
7th to Cherry
Trap Club

File details come from the government source that posted it. Updated .