ADDENDUM 1.pdf

PDF 11 MB Posted

Attached to
Vasquez Blvd. Sanitary Sewer Improvements
Solicitation number
1135-008
Issued by
Weld County, Pueblo City, Colorado

About this file

This document is Addendum No. 1 for the Vasquez Blvd. Sewer Improvements project in Platteville, Colorado, issued by Northern Engineering Services on February 7, 2024. The addendum modifies the original bidding documents from January 17, 2024, and includes changes to specifications and drawings. Key modifications include adding a Temporary Erosion and Sediment Control section, revising a note on Sheet 3 regarding a transformer, and adding erosion control details to multiple sheets. The addendum also provides clarifications to several bidder questions, including confirmation that Cretex Pro-Ring is acceptable, details about working around a transformer, potential road closures, Saturday work permissions, and apartment parking lot access.

The addendum includes additional technical and logistical information for potential bidders. Notable details include that roads could be closed with advance notice during sewer line crossings, Saturday work is permitted with advance notice and equipment start restrictions, and partial apartment parking lot closures are possible with specific coordination. The Town has some potential staging areas near Town Hall, and clean fill dirt can be delivered to 100 North Division Blvd. The document also addresses specific concerns about precast manhole lead times, with the Town potentially considering project time extensions if material production becomes an issue. The Platteville Apartments manager provided additional notes about an abandoned lawn sprinkler system and recommendations for protecting existing rock landscaping during construction.

View the file

Other files

File Type Posted
1135-008 Vasquez Blvd. Specifications.pdf PDF
ADDENDUM-2.pdf PDF
1135-008 Vasquez Blvd. Plans.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM NO. 1

February 7, 2024

RE: Vasquez Blvd. Sewer Improvements Platteville, Colorado Project No. 1135-008

FROM: Northern Engineering Services 820 8th Street Greeley, CO 80631

(970) 221-4158

TO: Prospective Bidders

This Addendum forms part of the Contract Documents and modifies the original Bidding Documents dated January 17, 2024. Acknowledge receipt of this Addendum in the space provided on the Bid Form.

Failure to do so may subject the Bidder to disqualification.

This Addendum consists of three pages and the following attached files: 1135-008 VASQUEZ SEWER 2-5- 24.pdf, and 01 57 13.pdf

CHANGES TO THE SPECIFICATIONS:

1. Section 01 57 13 – Temporary Erosion and Sediment Control has been added.

CHANGES TO THE DRAWINGS:

2. Sheet 3 of 8, EX1, note has been revised as follows: “CONTRACTOR TO WORK AROUND

TRANSFORMER AND CONDUIT. TRANSFORMER WILL NOT BE REMOVED OR RELOCATED.”

3. Sheet 4 of 9, SS1, erosion control added.

3. Sheet 5 of 9, SS2, erosion control added.

4. Sheet 9 of 9, D3, erosion control details added.

CLARIFICATIONS:

Q. Are Cretex Pro-Ring acceptable for the Platteville project.

A. It meets CDOT specs, so acceptable.

Q. Will the transformer box that is near the new manhole be removed before construction starts?

A. Work will need to be around transformer. Not scheduled for removal.

Q. It was mentioned that the road needs to remain with 1 lane traffic during construction. Can the road be closed during the crossing for each sewer line?

A. With advance notice, the roads could be closed for the crossing.

Q. Can the contractor work on Saturdays?

A. Yes, with advance notice and cannot start equipment prior to 8AM.

Q. Is the contractor able to shut down the apartment parking lot during the sewer installation?

A. VERY SPECIFIC COORDINATION with the apartment manager and residents; with enough notice, part of the parking lot could be shut down for a minimum amount of time.]

Q. Is there a designated staging area for this project?

A. A specific staging area close to the project has not been identified. The Town has some areas near Town Hall that could used if necessary.

Q. Can Flash Fill be used as a substitute for flow fill in the pipe abandonment?

A. Yes.

Q. Is there a soils report for this project?

A. No.

Q. Allow additional time project time for precast manholes (6-8 week lead time)?

A. No additional time is being considered at this time, however, if the precast manhole production lead time is an issue for the low Bidder, the Town will consider an extension of the project time. Please reflect any proposed delays in materials in your construction schedule to be submitted.

Q. Is the town interested in taking any leftover dirt? If so, what address would they want it delivered to?

A. CLEAN FILL DIRT only. 100 North Division Blvd.

Q. Will the moving of the electrical transformers be performed by others or is it the responsibility of the contractor?

A. Work will need to be around transformer. Not scheduled for removal.

COMMENTS FROM THE PLATTEVILLE APARTMENT’S MANAGER:

1. We have abandoned the old lawn sprinkler system at the Platteville Apts and installed rocks over plastic barrier landscaping. If the contractor finds that they have cut into this old system, there would be no reason to restore it.

2. When they dig their trenches and need to deposit the earth materials next to the trenches, they can save themselves a lot of work if they invest in lots of tarps to lay over the rocks before the dump the dirt into our rock landscaping. Separating out all that dirt from the rocks at a later date is going to be costly and never really gets done correctly. We bought the rocks for a reason and we don’t need any more dirt mixed in than we already have.

END OF ADDENDUM

TEMPORARY EROSION AND

SEDIMENT CONTROL 01 57 13-1

SECTION 01 57 13

TEMPORARY EROSION AND SEDIMENT CONTROL

PART 1 GENERAL

1.01 SUMMARY

A. Section Includes:

1. Temporary measures needed to control erosion and water pollution by use of berms, dikes, dams, sediment basins and /or traps, geotextiles, stone checks, hay bales, silt fences, surface roughing, mats and nets, aggregate, mulch, grasses, slope drains, and other approved measures at the locations necessary to control erosion and water pollution.

2. Coordinate temporary pollution controls with the permanent erosion control features specified.

B. Related Sections:

1. Section 01 57 26, Watering for Dust Control

2. Section 02 41 00, Site Demolition

3. Section 31 20 00, Earth Moving.

1.02 REFERENCES

A. “Urban Storm Drainage Criteria Manual, Volume 3, Stormwater Quality”, Urban Drainage and Flood Control District.

1.03 SUBMITTALS

A. Schedule:

1. Prepare schedules for accomplishing all required temporary and permanent erosion control work and submit them for acceptance at the preconstruction conference. Include all construction activities within the project, haul road, borrow pits, storage and plate sites, and the plan for disposal of waste material.

Do not start work until temporary erosion control schedules have been accepted.

B. Permit:

SEDIMENT CONTROL 01 57 13-2

1. Submit completed and approved Colorado Discharge Permit System – Stormwater Construction Permit (CDPS_SCP) with required Stormwater Management Plan (SWMP).

C. Permit Changes:

1. Submit any proposed changes to the permits for approval prior to doing the work.

1.04 QUALITY ASSURANCE

A. Preconstruction Conference:

1. CONTRACTOR shall assign an SWMP Administrator/Erosion Control Supervisor whose responsibility will be to fulfill the obligations listed below:

a. Have authority over all necessary labor and equipment to direct and channel new drainage which may develop on a daily or hourly basis into suitable temporary pollution and erosion control features wherever necessary during unforeseen or emergency situations, and of dismantling those features when their purpose has been fulfilled unless the ENGINEER directs that the facility be left in place as a permanent control feature. If removed, the area in which these features were constructed shall be returned to a condition reasonably similar to that which existed prior to its disturbance.

b. Be immediately available upon the ENGINEER’s request to implement necessary actions to reduce any anticipated or presently existing water quality or erosion problems resulting from construction activities. The criteria by which the ENGINEER initiates this action may be based on water quality data derived from monitoring operations or by any anticipated condition (e.g., predicted storms) that the ENGINEER believes could lead to unsuitable water quality situations.

c. Give high priority to actions deemed necessary by the ENGINEER to control adverse water quality impacts. The erosion control/water quality supervisor, must make immediately available all personnel and equipment judged appropriate by the ENGINEER to maintain suitable erosion control features. These actions requested by the ENGINEER take precedence over any other aspect of the project construction that has need of the same manpower and equipment.

d. Sample water and provide the appropriate reports of analytical test results on the water sampled, or hire a qualified firm approved by the ENGINEER to perform the sampling and testing of water samples at the locations and time schedule reqir4ed by the permits.

e. Obtain permits as required by local authorities having jurisdiction.

SEDIMENT CONTROL 01 57 13-3

1.05 TEMPORARY CONTROLS

A. Dust Control

1. The CONTRACTOR shall be responsible for the abatement and control of dust produced as a result of this contract. The CONTRACTOR, entirely at CONTRACTOR’S own expense, shall take all reasonable measures to control dust. This shall include dust control efforts when deemed necessary by the OWNER on weekends, holidays, and other time during the contract period when fugitive dust may be a problem.

2. Use water sprinkling, temporary enclosures, and other suitable methods to limit dust and dirt rising and scattering in air to lowest practical level. Comply with governing regulations pertaining to environmental protection.

3. Do not use water when it may create hazardous or objectionable conditions such as ice, flooding, and pollution.

B. Noise Control

1. Construction machinery and vehicles shall be equipped with practical sound muffling devices and operated in a manner to cause the least noise consistent with efficient performance of the work.

C. Pollution control

1. The CONTRACTOR shall prevent pollution by sanitary wastes, sediment, debris, and other substances resulting from construction activities by preventing sediment, debris or other substances from entering water systems, sanitary sewers, storm drains, and culverts and by retaining all spent oils, hydraulic fluids, and other petroleum fluids in containers for disposal off the site.

2. No dumping into or polluting of adjacent rivers will be allowed.

D. Erosion control

1. The CONTRACTOR shall prevent the erosion of soil on the site and adjacent properties that might result from construction activities.

2. The CONTRACTOR shall provide temporary materials such as hay bales, sand bags, silt fence, chain link fence fabric, rip rap or culverts to prevent the erosion of banks or excavation where runoff may be increased or concentrated due to construction activities.

SEDIMENT CONTROL 01 57 13-4

3. Clean adjacent structures and improvements of dust, dirt, and debris caused by construction operations, as directed by the ENGINEER and OWNER. Return adjacent areas to condition existing prior to start of work.

PART 2 PRODUCTS

2.01 MATERIAL

A. Mulches:

1. Mulches may be hay or straw, as noted in the plan general notes.

B. Grass:

1. Native grass seed mix as noted on the drawings or as approved by the

ENGINEER.

C. Erosion Bales:

1. Hay, straw or other approved material containing approximately 5 cubic feet of material and weighing not less than 35 pounds. Bales shall be bound with wire.

D. Anchor Stakes:

1. No. 4 reinforcing steel bars approximately 4 feet long or 2” x 2” x 3’ wood stakes.

E. Temporary Berms:

1. Construct berms from on site soil which is reasonably fine textured.

F. Silt Fence:

1. Plastic Filter Cloth: Manufactured especially for erosion control applications consisting of either polyvinylidene chloride nylon/polypropylene, or polypropylene monofilament yarns, with the following requirements:

TEST REQUIREMENTS (Minimum)

Thickness (ASTM D1910) 15 mils Grab Tensile Strength, Fill and Warp (ASTM D1682) 100 lbs.

Grab Elongation (ASTM D1685) 30% Toughness (grab tensile strength X Grab elongation) 5000 lbs. X % Trapezoid Tear (ASTM D2263) 60 lbs.

Coefficient of Friction (CFMC FFET-5) 0.4 Flow rate (head change from 30 cm to 10 cm) 220 gal/min/sf

SEDIMENT CONTROL 01 57 13-5

Pore Size (CFMC FFET-1) (maximum) 0.15 mm

2. Provide cloth insect, rodent, mildew and rot resistant.

3. Wire Mesh: Standard woven wire field fence, 832-6-11 (32” height), approximately 0.65 lbs/ft.

4. Alternate: 4” x 4” Wire “V” mesh (34” height), approximately 75 lbs/ft.

5. Posts: Metal or wood with a minimum length of 5 ft. Furnish metal posts

“studded tee” or “U” type with minimum weight of 1.28 lbs./lin. ft. with fin anchors sufficient to resist post movement or wood posts with a minimum diameter of 4 inches.

6. Wire Ties: 14-gage minimum.

7. Staples for Wood Posts: No. 9 wire minimum at least 1.5 inches long.

8. Sediment Traps: Construct from soil which is reasonably fine textured and well graded to minimize seepage. Do no use organic material.

G. Vehicle Tracking Control

1. Vehicle Tracking Control: 9-inch minimum thick stone stabilization mat.

2. Stone: 3 inch (D50) coarse aggregate.

3. Filter Layer: Geotextile material.

PART 3 EXECUTION

3.01 CONSTRUCTION REQUIREMENTS

A. General:

1. Implement, operate, and maintain in a safe manner all permanent or temporary erosion control features. It is the CONTRACTOR’s responsibility to conduct the construction work in such a manner to prevent contamination of adjacent steams, lakes, ponds, or other watercourses or water impoundment areas.

2. Include temporary pollution control in construction work outside the right-of-way where necessary for borrow pits, haul roads, and equipment storage sites.

3. Incorporate all permanent erosion control features into the project at the earliest predictable time as outlined in the accepted schedule. Maintain erosion control features until the project is accepted.

SEDIMENT CONTROL 01 57 13-6

4. Comply with all provisions contained within the dewatering and stormwater discharge permits, including sampling water, analytical testing of the water samples, and reporting the results to the regulatory agency.

B. Temporary Controls:

1. Provide temporary erosion and pollution control measures for the purpose of correcting conditions that develop during construction not foreseen during the design of the project, or during an emergency situation, and for the purpose of providing continuous erosion and sediment control for the duration of the project. Measures proposed by the CONTRACTOR must be reviewed and approved by the ENGINEER prior to installation.

C. Slopes:

1. Stabilize all cut and fill slopes with seeding, mulching, or other appropriate measures as the excavation proceeds where construction activity will not occur for a period of 14 or more calendar days.

D. Silt Fences:

1. Set stakes, excavate 4” x 4” trench upslope of stakes, place filter fabric, backfill and compact trench.

E. Straw Bales:

1. Excavate 4” depth trench the width of bale. Place bales in trench with tight abutting ends. Stake each bale with two stakes.

F. Concrete Truck Washout:

1. A temporary pit shall be used for concrete mixers and mix truck washout.

Excess concrete will not be discharged on-site, but shall remain in the trucks and returned to concrete batch plant. Dispose of hardened concrete offsite.

Concrete truck operators are prohibited from dumping or cleaning their trucks in any manner that results in water discharge into storm drains. Inspect the washout area daily for runoff control adequacy and weekly for removal of hardened concrete

G. Vehicle Tracking Control

1. Locate at points of vehicle ingress to construction site.

2. Fill entire vehicle tracking control area with 9-inch minimum thickness of stone aggregate. Screed and roller compact to provide uniform base.

H. Dewatering:

SEDIMENT CONTROL 01 57 13-7

1. Conduct dewatering (uncontaminated-concentration below target clean-up levels) or excavations in a manner that avoids pollution and erosion. Water from dewatering operations shall not be discharged into natural steams or waterways, into irrigation ditches or canals, or into storm sewers, unless allowed by a point source discharge permit. Discharge into sanitary sewers shall not be allowed unless written permission of the OWNER or controlling authority is obtained and this disposal method is approved by the ENGINEER. Contain water from dewatering operations in settling basins to allow sediment deposition and sampling and testing for groundwater contaminants.

I. Unacceptable Applications:

1. Sprinkler or aerial application shall not be used unless approved by the

ENGINEER.

J. Conflicts:

1. In the event of conflicts between these requirements and water quality control laws, rules, or regulations of other Federal, State, or local agencies, the more restrictive laws, rules, or regulations shall apply.

3.02 WATER QUALITY MANAGEMENT REQUIREMENTS

A. Compliance:

1. Take all reasonable steps to comply with the applicable standards, permit conditions, and regulations of appropriate agencies.

B. Start of Work:

1. Install permanent erosion and sediment control measures at the earliest practicable time. As one of the first construction activities, place permanent and temporary erosion and sediment control measures around the perimeter of the project or the initial work areas.

C. Coordination:

1. Coordinate temporary erosion and sediment control measures with permanent measures to ensure economical, effective, and continuous control throughout the construction phase.

D. Disposal:

1. Pollutant byproducts of construction, solids, sludges, pollutants removed in the course of treatment of wastewater, excavation, or excess fill material, and material from sediment traps shall be handled, stockpiled, or disposed of in such a manner so entry into any waterbodies, wetlands, or impoundments within or outside the project boundaries is prevented.

SEDIMENT CONTROL 01 57 13-8

E. Use of Hazardous Materials:

1. The use of chemicals such as soil stabilizers, dust palliatives, sterilants, growth inhibitors, fertilizers, deicing salts, etc., during construction shall be in accordance with the manufacturer’s recommended application rates, frequency, and instructions. These chemicals shall not be used, stored, or stockpiled within 50 feet of the ordinary high water line of any watercourse or impoundment. Where these chemicals are stored or stockpiled, spill prevention and containment measures shall be taken to prevent the pollution of any watercourse or impoundment due to accidental spills.

F. Storage:

1. Do not store or stockpile any construction waste or salvable material, excavation excess material, fill material, construction equipment, and other material stockpiles within 50 feet of the ordinary high water line of any watercourse or impoundment.

G. Permit Changes:

1. When a project is subject to a water quality permit, the quantities, locations, and compositions of discharges, the quantities of dredging and fills, and the erosion and sediment control measures will be stated in the permit. If the CONTRACTOR anticipates a change from permit conditions, or if construction activities result in noncompliance with the permit conditions, the CONTRACTOR shall verbally notify ENGINEER within 24 hours and detail the anticipated changes or noncompliance in a written report. The submission of the report shall be within four days from the time the CONTRACTOR becomes aware of change or noncompliance. Within 10 days after receipt of the report, the ENGINEER will approve or disapprove the request for change, or detail the course of action after noncompliance.

F. Compliance with Contract:

1. Any diversion from, or bypass of, facilities necessary to maintain compliance with the terms and conditions contained in the Contract is prohibited except, (1) where unavoidable to prevent loss of life or sever property damage, or (2) where excessive storm drainage or runoff would damage the facilities; however, this exception is not satisfied if the CONTRACTOR could have installed adequate backup equipment to prevent a bypass which occurred during normal periods of equipment downtime or preventative maintenance. If diversion or bypass of the facilities occurs, the CONTRACTOR shall verbally notify the ENGINEER within 24 hours and in writing within four days of the occurrence. The ENGINEER will assess the damage, if any, resulting from the occurrence, and detail a course of action.

G. Seeding:

SEDIMENT CONTROL 01 57 13-9

1. Seed or revegetate all areas indicated at the earliest practicable time to prevent soil erosion. Comply with the requirements of these specifications if seeding is to remain in-place at completion of the contract.

H. Fill Material:

1. Furnish, place, and compact fill materials following requirements of Section 31 20 00, Earth Moving.

I. Waste Material:

1. Do not place plastic, concrete or any other construction material into wetlands, watercourses, or impoundments.

3.03 MAINTENANCE

A. Continuously maintain all erosion and sediment control measures so that they perform their intended function during the construction of the project.

B. Remove and replace sediment laden and ineffective bales with new straw bales.

C. Remove and replace damaged or ineffective silt fences.

END OF SECTION

D

IV

IS

IO

N S

T.

U .S

.8

M

AI

N S

T.

WCR 30

S.

F

R O

N T

ST

R

EE

T

WCR 30

Byers Ave.

Va sq ue z

Bl vd

Salisbury Ave.

JANUARY 2024 CONTACT INFORMATION

PROJECT TEAM:

Northern Engineering Services, Inc.

Bradley Curtis, PE 820 8th Street Greeley, Colorado 80631

(970) 221-4158

Northern Engineering Services, Inc.

Tim Foglesong, PLS 820 8th Street Greeley, Colorado 80631

(970) 221-4158

E NG I NE E R NGI

EHTRON RN

E NG I NE E R NGI

EHTRON RN

PROJECT

LOCATION

VICINITY MAP

NORTH

SITE ENGINEER

SURVEYOR

Northern Engineering Services, Inc NE Project No. 1135-008 Date: March 6, 2023

ORIGINAL FIELD SURVEY BY:

SHEET INDEX

CONSTRUCTION PLANS FOR

VASQUEZ SEWER PROJECT

OWNER

LOCATED IN THE SOUTHWEST QUARTER OF SECTION 19,

TOWNSHIP 3 NORTH, RANGE 67 WEST OF THE 6TH P.M.

TOWN OF PLATTEVILLE, COUNTY OF WELD, STATE OF COLORADO

Town of Platteville 400 Grand Avenue Platteville, CO, 80651

(970) 785-2245

NOTES:

HORIZONTAL DATUM: COORDINATE SYSTEM IS A NORTHERN ENGINEERING LOCAL

COORDINATE SYSTEM BASED ON NGS "PLATTEVILLE" (300000,600000). KNOWN INTERNALLY

AS "PLATTEVILLE LOCAL". LINEAL MEASURE IS BASED ON THE U.S. SURVEY FOOT.

VERTICAL DATUM: VERTICAL DATUM IS NAVD88 USING GEOID MODEL "CO G18 GRS80"

- BENCHMARK: NGS BENCHMARK "J 391" (NAVD88 ELEV=4801.03)

CS1

C O

V E

R S

H E

E T

1. The Contractor shall notify all utility companies including but not limited to Atmos Energy (gas), CenturyLink (telephone), Xcel Energy (power), the Town of Platteville Public Works Department and the Town of Platteville Water & Sewer Department prior to commencing construction to have all lines and conduits field located.

2. The size, type and location of all known underground utilities are approximate when shown on these drawings. It shall be the responsibility of the Contractor to locate all underground utilities in the area of the work before commencing new construction.

3. All work shall be constructed to the Town of Platteville Standard Specifications unless these plans & specifications are more restrictive, in which case they shall control.

4. Contractor shall have a registered land surveyor tie out & reset any property corners or section corners to be disturbed.

5. All project control listed hereon is provided as a courtesy. It is the responsibility of the Contractor to verify the accuracy of the coordinates and elevations shown prior to using them for any purposes.

NOTES:

CALL UTILITY NOTIFICATION CENTER OF

COLORADO

Know what's below.

before you dig.Call

R

UTILITY NOTE:

THE LOCATION OF UNDERGROUND UTILITIES AS SHOWN ARE BASED

ON OBSERVED EVIDENCE AND UTILITY MARKINGS AT TIME OF SURVEY.

ADDITIONAL UTILITY LINES MAY EXIST. THE EXACT LOCATION OF ANY

UNDERGROUND UTILITIES SHOWN AND THE LOCATION OF ANY

ADDITIONAL UNDERGROUND UTILITIES SHOULD BE DETERMINED BY

CONTACTING "ONE CALL" FOR A UTILITY LOCATE.

UTILITY CONTACT LIST: *

UTILITY COMPANY

* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information.

PHONE NUMBER

GAS----------------- Atmos Energy--------------------------- Christine McDermott (970) 304-2080 ELECTRIC-------- Xcel Energy------------------------------ Peter Stitt (970) 602-1662 TELECOM.--------CenturyLink-------------------------------Robert Rulli (970) 490-7503 WATER------------ Town of Platteville Public Works----David Brand (970) 785-6415 WASTEWATER--Town of Platteville Public Works----David Brand (970) 785-6415 STORMWATER- Town of Platteville Public Works----David Brand (970) 785-6415

Sheet

V A

S Q

U E

Z S

E W

E R

P R

O

JE

C T

Th es e dr aw in gs a re in st ru m en ts o f s er vi ce pr ov id ed b y

N or th er n En gi ne er in g Se rv ic es In c.

an d ar e no t to b e us ed fo r an y ty pe o f c on st ru ct io n un le ss s ig ne d an d se al ed b y a P ro fe ss io na l E ng in ee r in th e em pl oy o f N or th er n En gi ne er in g Se rv ic es In c.

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

R E

V

IE

W S

E T

SHEET INDEX

PL

AT

TE

VI

LL

E, C O

LO

R

AD

O

UTILITY LOCATOR

Colorado Utility Finders PO Box 7506 Loveland, CO 80537 Phone: (303) 817-3386 Email: info@coloradoutilityfinders.com

UTILITY LOCATOR

Rocky Mountain Utility Locating Michael Sweney Loveland, CO 80537 Phone: (970) 370-8111 Email: info@rmlocating.com

PROJECT GENERAL NOTES

1. ALL CONSTRUCTION WORK SHALL BE IN ACCORDANCE WITH THE TOWN OF PLATTEVILLE'S STANDARD SPECIFICATIONS, LATEST EDITION.

2. TYPE OF COMPACTION FOR THIS PROJECT SHALL BE AASHTO T-99 (ASTM D698) (STANDARD PROCTOR) FOR SUBGRADE SOILS AND AASHTO T-180 (ASTM D1557) (MODIFIED PROCTOR) FOR AGGREGATE BASE COURSE.

3. THE CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL, AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE NECESSARY EQUIPMENT AND MATERIALS TO SATISFACTORILY CONTROL DUST AT ALL TIMES, AND AS DIRECTED BY THE TOWN. WATER SHALL BE USED AS THE DUST PALLIATIVE WHERE REQUIRED. THE CONTRACTOR

WILL FURNISH AND SPREAD WATER AT NO ADDITIONAL COST TO THE PROJECT.

4. DEPTH OF MOISTURE-CONTROL FOR THIS PROJECT SHALL BE AS FOLLOWS:

FULL DEPTH OF ALL EMBANKMENTS

BASE OF CUTS AND FILLS, 0.5 FT.

EXCAVATION AND DIGGING AS REQUIRED FOR THE COMPACTION OF BASES OF CUTS AND FILLS WILL BE CONSIDERED

SUBSIDIARY TO THAT OPERATION AND WILL NOT BE PAID FOR SEPARATELY.

5. WHEN EXISTING ASPHALT PAVEMENT IS TO BE REMOVED, IT SHALL BE CUT TO A NEAT WORK LINE WITH A CUTTING WHEEL ATTACHED TO A BLADE, SAW OR OTHER METHODS AS APPROVED BY THE ENGINEER. THIS WORK WILL NOT BE

PAID FOR SEPARATELY BUT SHALL BE CONSIDERED AS SUBSIDIARY TO OTHER WORK.

6. ALL DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS SHALL BE REMOVED FROM THE SITE AND LEGALLY DISPOSED OF OFF-SITE. LOCATION OF DUMP, LENGTH OF HAUL, AND DISPOSAL EXPENSES

SHALL BE CONTRACTOR'S RESPONSIBILITY.

7. THE STREETS ADJACENT TO THE CONSTRUCTION AREA SHALL BE CLEARED OF DEBRIS GENERATED BY THE PROJECT BY THE CONTRACTOR AT THE EARLIEST OPPORTUNITY, BUT IN NO CASE SHALL THE ROADS BE LEFT UNCLEARED AFTER THE COMPLETION OF THE DAY'S WORK. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE NECESSARY EQUIPMENT AND MATERIAL TO SATISFACTORILY CLEAN THE ROADWAYS AT NO ADDITIONAL COST TO THE

PROJECT.

8. THERE SHALL BE A MINIMUM 12" VERTICAL SEPARATION WHERE UTILITY SLEEVES ARE LOCATED IN THE SAME TRENCH.

9. CONTRACTOR SHALL SUBMIT AS-BUILT INFORMATION TO THE PROJECT ENGINEER TO REVIEW AND PREPARE FINAL

AS-BUILT RECORD DRAWINGS.

10. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS PRIOR TO COMMENCEMENT OF ANY WORK WITHIN THE RIGHT-OF-WAY. A PERMIT FROM PUBLIC WORKS IS REQUIRED FOR ALL CONSTRUCTION IN PUBLIC RIGHT-OF-WAY OR EASEMENTS. A PRE-CONSTRUCTION CONFERENCE SHALL BE HELD WITH TOWN REPRESENTATIVES

BEFORE A PERMIT WILL BE ISSUED.

11. THE CONTRACTOR SHALL NOTIFY PUBLIC WORKS AT LEAST 24-HOURS PRIOR TO THE DESIRED INSPECTION WITHIN THE

RIGHT-OF-WAY.

12. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE TOWN OF ANY PROBLEMS IN CONFORMING TO THE ACCEPTED PLANS FOR ANY ELEMENT OF THE PROPOSED IMPROVEMENTS PRIOR TO ITS CONSTRUCTION.

13. IT IS THE RESPONSIBILITY OF THE CONTRACTOR DURING CONSTRUCTION ACTIVITIES TO RESOLVE CONSTRUCTION PROBLEMS DUE TO CHANGED CONDITIONS, OR DESIGN ERRORS ENCOUNTERED BY THE CONTRACTOR DURING THE PROGRESS OF ANY PORTION OF THE PROJECT. IF THE MODIFICATIONS PROPOSED BY THE CONTRACTOR TO THE ACCEPTED PLANS INVOLVE SIGNIFICANT CHANGES TO THE CHARACTER OF THE WORK, OR TO THE FUTURE CONTIGUOUS PUBLIC OR PRIVATE IMPROVEMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR RE-SUBMITTING THE REVISED PLANS TO THE TOWN OF PLATTEVILLE FOR ACCEPTANCE PRIOR TO ANY FURTHER CONSTRUCTION RELATED TO THAT PORTION OF THE PROJECT. ANY IMPROVEMENTS NOT CONSTRUCTED IN ACCORDANCE WITH THE ACCEPTED PLANS, OR THE ACCEPTED REVISED PLANS, SHALL BE REMOVED AND RECONSTRUCTED ACCORDING TO

THE APPROVED PLAN.

14. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS AT AND ADJACENT TO THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND SHALL NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE TOWN TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR THE CONSTRUCTION

SITE.

15. THE CONTRACTOR SHALL PROVIDE ALL LIGHTS, SIGNS, BARRICADES, FLAG PERSONS, OR OTHER DEVICES NECESSARY TO PROVIDE FOR PUBLIC SAFETY IN ACCORDANCE WITH THE CURRENT MANUAL ON UNIFORM TRAFFIC CONTROL

DEVICES.

16. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL SURVEY MONUMENTS. ANY MONUMENT THAT MUST BE DESTROYED FOR CONSTRUCTION MUST BE REPLACED. THE CONTRACTOR SHALL ENGAGE THE SERVICES OF A

LICENSED SURVEYOR PRIOR TO DISTURBING ANY MONUMENTS.

17. REPRODUCIBLE COPIES OF RECORD DRAWING PLANS SHALL BE SUBMITTED TO THE TOWN OF PLATTEVILLE PRIOR TO

CONSTRUCTION ACCEPTANCE OF THE PUBLIC IMPROVEMENTS.

CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU

DIG, GRADE, OR EXCAVATE FOR THE MARKING OF

UNDERGROUND MEMBER UTILITIES.

CALL UTILITY NOTIFICATION CENTER OF

COLORADO

Know what'sbelow.

before you dig.Call

R

STRIPING NOTES

1. ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THESE PLANS, AS WELL AS THE TRAFFIC SIGNING

AND MARKING CONSTRUCTION NOTES LISTED HERE.

2. ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMED THERMO-PLASTIC.

3. ALL SIGNAGE SHALL BE PER TOWN OF PLATTEVILLE AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD.

4. ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS.

5. ALL LANE LINES FOR CONCRETE PAVEMENT SHALL BE EPOXY PAINT.

6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE CONTRACTOR SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMEMT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE TOWN ENGINEERS PRIOR TO PERMANENT INSTALLATION OF STRIPING AND SYMBOLS.

7. PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS.

8. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE

CONSTRUCTION.

9. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS.

10. ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS.

11. A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE TOWN'S ENGINEERS. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE

2-YEAR WARRANTY PERIOD WILL BEGIN.

12. THE SUB-CONTRACTOR OR CONTRACTOR INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING

ALL UNDERGROUND UTILITIES.

13. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN.

14. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD. THE TOWN RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE TOWN DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS).

Sheet

V A

S Q

U E

Z S

E W

E R

P R

O

JE

C T

Th es e dr aw in gs a re in st ru m en ts o f s er vi ce pr ov id ed b y

N or th er n En gi ne er in g Se rv ic es In c.

an d ar e no t to b e us ed fo r an y ty pe o f c on st ru ct io n un le ss s ig ne d an d se al ed b y a P ro fe ss io na l E ng in ee r in th e em pl oy o f N or th er n En gi ne er in g Se rv ic es In c.

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

R E

V

IE

W S

E T

CS2

G E

N E

R A

L N

O

TE

S

PL

AT

TE

VI

LL

E, C

O

LO

R

AD

O

GENERAL NOTES-WATER & SANITARY SEWER

1. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION. CALL UTILITY NOTIFICATION CENTER OF

COLORADO AT 811 (or 1-800-922-1987) AT LEAST 48 HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING.

2. MAINTAIN A MINIMUM OF 10 FOOT HORIZONTAL CLEAR DISTANCE SEPARATION BETWEEN POTABLE WATER AND SANITARY SEWER OR NON-POTABLE IRRIGATION MAINS AND SERVICES. POTABLE WATER MAINS AND SERVICES ARE TO BE LOCATED 18 INCHES MINIMUM ABOVE THE SANITARY SEWER OR NON-POTABLE IRRIGATION MAIN OR SERVICES. IF FIELD CONDITIONS VARY FROM THOSE SHOWN ON THESE PLANS AND THE SANITARY SEWER OR NON-POTABLE CANNOT BE LOCATED BELOW THE WATER MAIN OR SERVICE, A CLEAR VERTICAL DISTANCE OF 18 INCHES CANNOT BE MAINTAINED, OR A MINIMUM 10 FOOT HORIZONTAL SEPARATION CANNOT BE ACHIEVED, THE TOWN OF EATON'S

INSPECTION SERVICES SHALL BE CONTACTED IMMEDIATELY TO REVIEW THE SITUATION.

3. WHERE SANITARY SEWER LINES CROSS BENEATH POTABLE WATER LINES WITH LESS THAN EIGHTEEN (18") INCHES CLEARANCE, SANITARY SEWER LINES CROSS ABOVE POTABLE WATER LINES, OR THE TEN (10') FEET HORIZONTAL CLEARANCE BETWEEN POTABLE WATER LINES AND SANITARY SEWER LINES CANNOT BE MAINTAINED, PIPE ENCASEMENT SHALL BE DESIGNED AND CONSTRUCTED SO AS TO PROTECT THE POTABLE WATER MAIN.

4. CONTRACTOR SHALL NOTIFY THE TOWN OF PLATTEVILLE (DAVID BRAND, 970-539-3001) ONE WEEK PRIOR TO COMMENCING WORK AFTER TOWN-ACCEPTED CONSTRUCTION DRAWING DISTRIBUTION AND A PRE-CONSTRUCTION

MEETING HAS BEEN HELD WITH THE TOWN.

5. CONTRACTOR SHALL POTHOLE ALL EXISTING UTILITIES TO BE CROSSED BY POTABLE WATER, SANITARY SEWER OR NON-POTABLE IRRIGATION LINES AT LEAST 24 HOURS PRIOR TO CROSSING TO ENSURE 18 INCH MINIMUM CLEARANCE IF OPEN CUT CROSSING METHODS ARE USED AND 36 INCH MINIMUM CLEARANCE FOR BORED CROSSINGS. IF VERTICAL CLEARANCE CANNOT BE MET AS SHOWN ON THE DRAWINGS, CONTACT THE DESIGN ENGINEER IMMEDIATELY.

HORIZONTAL AND VERTICAL LOCATION OF CROSSED EXISTING UTILITIES SHALL BE RECORDED ON THE

AS-CONSTRUCTED RECORD DRAWINGS.

6. SHOULD ANY VARIATIONS BEFORE OR DURING CONSTRUCTION TO THE POTABLE WATER MAIN OR SANITARY SEWER COLLECTION, OR NON-POTABLE IRRIGATION SYSTEM DESIGNS BE CONSIDERED, NOTICE MUST FIRST BE GIVEN TO THE TOWN'S INSPECTOR TO DETERMINE IF IT NEEDS ACCEPTANCE BY THE TOWN. IF SO, THE NEW PLAN MUST BE DRAWN AND SUBMITTED TO THE TOWN FOR ACCEPTANCE BY THE DEVELOPER'S ENGINEER 72 HOURS PRIOR TO

CONSTRUCTION.

7. FINAL CONSTRUCTION PLANS ARE VALID FOR CONSTRUCTION ONE (1) YEAR FROM THE DATE OF TOWN SIGNATURE

ACCEPTANCE.

8. ALL EXISTING POTABLE WATER MAINS, SERVICES, AND HYDRANT LINES SHALL HAVE A MINIMUM COVER OF FIVE (5) FEET AND A MAXIMUM COVER OF SIX (6) FEET UNLESS OTHERWISE INDICATED ON THE ACCEPTED CONSTRUCTION DRAWINGS.

9. VERIFICATION SURVEY - TOP OF PIPE ELEVATIONS AT ALL POTABLE AND NON-POTABLE WATER LINE VALVES AND SANITARY SEWER MANHOLE INVERTS SHALL BE SURVEYED AND PROVIDED TO THE TOWN BY THE DESIGN ENGINEER FOR ACCEPTANCE PRIOR TO PAVING CONSTRUCTION. THE VERIFICATION SURVEY SHALL ALSO PROVIDE SEWER PIPE SLOPES AND LENGTH AND PROPOSED FINISHED GROUND ELEVATIONS AT ALL VALVE BOXES AND MANHOLE RIM

ELEVATIONS.

10. ALL UTILITY CONDUIT CROSSINGS OF POTABLE WATER, SANITARY SEWER AND NON-POTABLE IRRIGATION LINES MUST BE ENCASED IN HIGH DENSITY POLYETHYLENE (HDPE) PIPE, WITH MINIMUM STANDARD DIMENSION RATIO (SDR) 11, ACROSS THE ENTIRE EASEMENT OR RIGHT-OF-WAY WIDTH. THE ENCASEMENT JOINT SHALL BE BUTT FUSED. FLEXIBLE

JOINTS ARE NOT ALLOWED.

11. WATER AND SANITARY SEWER WARRANTY PERIOD WILL NOT BEGIN UNTIL AS-BUILT RECORD DRAWINGS ARE ACCEPTED

BY THE TOWN OF PLATTEVILLE PUBLIC WORKS DEPARTMENT.

12. NO POLYVINYL CHLORIDE (PVC) PIPE STORED OUTSIDE AND EXPOSED TO SUNLIGHT SHALL EXCEED THE MANUFACTURER'S RECOMMENDATION EXPOSURE TIME. THIS TIME SHALL BEGIN FROM THE DATE OF MANUFACTURE. IF THE TIME WILL BE GREATER THAN THE MANUFACTURE'S RECOMMENDED TIME, THE PIPE SHALL BE COVERED WITH AN

OPAQUE MATERIAL. AIR CIRCULATION SHALL BE PROVIDED UNDER THE COVERING.

13. ALL NEW UNDERGROUND UTILITIES MUST BE ELECTRONICALLY LOCATABLE WHEN INSTALLED, PER COLORADO REVISED STATUE 9-1.56-103. REFER TO CITY OF GREELEY STANDARD DETAILS W-1 AND WS-4 FOR MORE INFORMATION ON

TRACER WIRE INSTALLATION.

14. FOR PUBLIC WATER OR SEWER LINES LOCATED IN PRIVATE ROADS OR EASEMENTS: FUTURE REPAIR OF PAVING, LANDSCAPING, OR OTHER IMPROVED SURFACES SUBSEQUENT TO THE REPAIR OF A WATER OR SEWER LINE SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER. THE TOWN OF EATON'S WATER AND SEWER DEPARTMENT WILL BACKFILL THE TRENCH TO THE SURFACE BUT NOT REBUILD ANY SURFACE IMPROVEMENTS OR REPLACE LANDSCAPING.

15. ALL SANITARY SEWER LINES SHALL BE ASTM D-3034 (PVC SDR 35) UNLESS OTHERWISE NOTED.

16. PVC SEWER PIPE SHALL BE INSTALLED USING A CDOT CLASS B BEDDING 6 INCHES ABOVE & 6 INCHES BELOW THE PIPE.

17. POTABLE WATER AND SANITARY SEWER SERVICES AND DISTRIBUTION/COLLECTION MAINS SHALL HAVE A MINIMUM OF TEN (10') FEET HORIZONTAL & EIGHTEEN (18") INCHES VERTICAL SEPARATION FROM ALL UTILITIES MEASURED FROM

OUTSIDE DIAMETER.

18. CONTRACTOR TO OBTAIN ALL PERMITS, DO ALL EXCAVATION FOR OSHA SAFE TRENCH.

19. INSULATION BOARD SHALL BE INSTALLED ABOVE THE BEDDING ZONE WHEN THE DEPTH OF COVER OVER ANY SANITARY

SEWER PIPE IS LESS THAN FOUR (4') FEET.

19.1. INSULATION BOARD INSTALLATION SHALL CONSIST OF TWO (2) OVERLAPPING BOARDS, ONE INCH (1") MINIMUM

THICKNESS PER BOARD, WITH OFF-SET JOINTS.

19.2. INSULATION BOARD SHALL BE PLACED ACROSS THE FULL WIDTH OF THE TRENCH.

19.3. ACCEPTABLE INSULATION BOARD MANUFACTURERS ARE:

19.3.1. DOW CHEMICAL COMPANY

19.3.2. OWENS-CORNING

19.3.3. OR APPROVED EQUIVALENT

S

S

S

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

S

C

W

TT

E

GAS

CONTROL

IRR

CONTROL

IRR

W

W CS

W

CS

ELEC

CS

W

HY D

HY D

H2O

S

G

C

CC

ELEC

BRKR

E

EG

GE

SS

SS

SS

SS

SS

SS

SS

O H

U

S

C.O.

C.O.

CONTROL

IRR

SS

SS

SS

SS

SS

SS

SS SS

X

X

X

X

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

CTV CTV CTV CTV CTV CTV

CTV

G G

W W W W W W W W W W W W W W W

W W

W W

W W

W W

W W

W

G G

G

G G G G G G G G

G

W

W

G G

G

G G

G

E

EEE

E E

EE

W W

G G

G G

G G

G G

G G

G

W W

W

E

E

W

W W

W W

W W

G G

E

E

E

SS

SS

SS

SS

SS

G GSSSSSS

SS

CTV

E E

E

W

CTV CTV CTV CTV CTV

C

TV

CTV CTV CTV CTV CTV

C

TV

OHU OHU OHU OHU OHU OHU

4" W 4" W 4" W 4" W 4" W 4" W 4" W 4" W 4" W

4" W 4" W

ELEC

SALISBURY AVENUE

VA

SQ

U

EZ

B O

U

LE

VA

R

D

VA

SQ

U

EZ

B

O U

LE

VA

R D

AN

N

P

LA

C E

AN

N

P

LA

C E

SANITARY MANHOLE 7152

RIM = 4820.36

INV(W) 4816.41' 8" PVC

INV(N) 4816.36' 8" PVC

SANITARY MANHOLE 7153

RIM = 4820.83'

INV(S) 4814.18' 8" PVC

INV(N) 4814.13' 8" PVC

SANITARY MANHOLE 7155

RIM = 4815.80

INV(S) 4810.90' 8" PVC

INV(N) 4810.93' 8" PVC

SANITARY MANHOLE 7156

RIM = 4817.60

INV(S) 4812.00 8" PVC

INV(N) 4811.90 8" PVC

8" CONCRETE WALL

12" BRICK WALL

6" CONCRETE

WALL

ADDITIONAL UNDERGROUND CABLE LINE

LOCATED IN SAME LOCATION

18" CMP

FLOWLINE = 4816.53

UNIDENTIFIED

WATERLINE

FEATURE

POSSIBLE OLD

FIRE HYDRANT

CLEANOUT

RIM = 4821.71

FL/BOTTOM = 4817.07

CLEANOUT

RIM = 4821.89

FL/BOTTOM = 4816.44

4" WOOD LANDSCAPE WALL

BYERS AVE

S

S

S

S

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

S

C

W

TT

E

GAS

CONTROL

IRR

CONTROL

IRR

W

W CS

W

CS

ELEC

CS

W

HY D

HY D

H2O

S

G

C

CC

ELEC

BRKR

E

EG

GE

SS

SS

SS

SS

SS

SS

SS

O H

U

S

C.O.

C.O.

CONTROL

IRR

SS

SS

SS

SS

SS

SS

SS SS

X

X

X

X

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

CTV CTV CTV CTV CTV CTV

CTV

G G

W W W W W W W W W W W W W W W

W W

W W

W W

W W

W W

W

G G

G

G G G G G G G G

G

W

W

G G

G

G G

G

E

EEE

E E

EE

W W

G G

G G

G G

G G

G G

G

W W

W

E

E

W

W W

W W

W W

G G

E

E

E

SS

SS

SS

SS

SS

G GSSSSSS

SS

CTV

E E

E

W

CTV CTV CTV CTV CTV

C

TV

CTV CTV CTV CTV CTV

C

TV

OHU OHU OHU OHU OHU OHU

4" W 4" W 4" W 4" W 4" W 4" W 4" W 4" W 4" W

4" W 4" W

ELEC

SALISBURY AVENUE

VA

SQ

U

EZ

B O

U

LE

VA

R

D

VA

SQ

U

EZ

B

O U

LE

VA

R D

AN

N

P

LA

C E

AN

N

P

LA

C E

SANITARY MANHOLE 7152

RIM = 4820.36

INV(W) 4816.41' 8" PVC

INV(N) 4816.36' 8" PVC

SANITARY MANHOLE 7153

RIM = 4820.83'

INV(S) 4814.18' 8" PVC

INV(N) 4814.13' 8" PVC

SANITARY MANHOLE 7155

RIM = 4815.80

INV(S) 4810.90' 8" PVC

INV(N) 4810.93' 8" PVC

SANITARY MANHOLE 7156

RIM = 4817.60

INV(S) 4812.00 8" PVC

INV(N) 4811.90 8" PVC

8" CONCRETE WALL

12" BRICK WALL

6" CONCRETE

WALL

ADDITIONAL UNDERGROUND CABLE LINE

LOCATED IN SAME LOCATION

18" CMP

FLOWLINE = 4816.53

UNIDENTIFIED

WATERLINE

FEATURE

POSSIBLE OLD

FIRE HYDRANT

CLEANOUT

RIM = 4821.71

FL/BOTTOM = 4817.07

CLEANOUT

RIM = 4821.89

FL/BOTTOM = 4816.44

4" WOOD LANDSCAPE WALL

BYERS AVE

S

S

S

S

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

S

C

W

TT

E

GAS

CONTROL

IRR

CONTROL

IRR

W

W CS

W

CS

ELEC

CS

W

HY D

HY D

H2O

S

G

C

CC

ELEC

BRKR

E

EG

GE

SS

SS

SS

SS

SS

SS

SS

O H

U

S

C.O.

C.O.

CONTROL

IRR

SS

SS

SS

SS

SS

SS

SS SS

X

X

X

X

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

CTV CTV CTV CTV CTV CTV

CTV

G G

W W W W W W W W W W W W W W W

W W

W W

W W

W W

W W

W

G G

G

G G G G G G G G

G

W

W

G G

G

G G

G

E

EEE

E E

EE

W W

G G

G G

G G

G G

G G

G

W W

W

E

E

W

W W

W W

W W

G G

E

E

E

SS

SS

SS

SS

SS

G GSSSSSS

SS

CTV

E E

E

W

CTV CTV CTV CTV CTV

C

TV

CTV CTV CTV CTV CTV

C

TV

OHU OHU OHU OHU OHU OHU

4" W 4" W 4" W 4" W 4" W 4" W 4" W 4" W 4" W

4" W 4" W

ELEC

SALISBURY AVENUE

VA

SQ

U

EZ

B O

U

LE

VA

R

D

VA

SQ

U

EZ

B

O U

LE

VA

R D

AN

N

P

LA

C E

AN

N

P

LA

C E

SANITARY MANHOLE 7152

RIM = 4820.36

INV(W) 4816.41' 8" PVC

INV(N) 4816.36' 8" PVC

SANITARY MANHOLE 7153

RIM = 4820.83'

INV(S) 4814.18' 8" PVC

INV(N) 4814.13' 8" PVC

SANITARY MANHOLE 7155

RIM = 4815.80

INV(S) 4810.90' 8" PVC

INV(N) 4810.93' 8" PVC

SANITARY MANHOLE 7156

RIM = 4817.60

INV(S) 4812.00 8" PVC

INV(N) 4811.90 8" PVC

8" CONCRETE WALL

12" BRICK WALL

6" CONCRETE

WALL

ADDITIONAL UNDERGROUND CABLE LINE

LOCATED IN SAME LOCATION

18" CMP

FLOWLINE = 4816.53

UNIDENTIFIED

WATERLINE

FEATURE

POSSIBLE OLD

FIRE HYDRANT

CLEANOUT

RIM = 4821.71

FL/BOTTOM = 4817.07

CLEANOUT

RIM = 4821.89

FL/BOTTOM = 4816.44

4" WOOD LANDSCAPE WALL

BYERS AVE

PROPOSED PRIVATE

SANITARY SEWER

ALIGNMENT

PROPOSED

MANHOLE

PROPOSED

MANHOLE

PROPOSED

MANHOLE

PROPOSED

MANHOLE

PROPOSED

MANHOLE

PROPOSED PUBLIC

SANITARY SEWER

ALIGNMENT

PROPOSED PUBLIC

SANITARY SEWER

ALIGNMENT

PROPOSED PRIVATE

SANITARY SEWER

ALIGNMENT

EXISTING

SANITARY

LINE TO BE

ABANDONED

EXISTING SANITARY

LINE TO BE ABANDONED

APPROXIMATE

ROW

APPROXIMATE

ROW

APPROXIMATE

ROW

GAS METERS

EXISTING 4" WATER MAIN

EXISTING 10" WATER MAIN

EXISTING 2" GAS LINE

PROTECT

POWER POLE DURING

CONSTRUCTION

EXISTING SANITARY

SEWER LINE

EXISTING SANITARY

SEWER LINE

EXISTING SANITARY

SEWER LINE

REMOVE/REPLACE

GRASS

REMOVE/REPLACE

TREE

REMOVE/REPLACE

VERTICAL CURB

AND GUTTER/

REMOVE/REPLACE

ASPHALT

PROPOSED

MANHOLE

REMOVE/REPLACE

GRAVEL

APPROXIMATE

ROW

REMOVE/REPLACE

GRAVEL

REMOVE/REPLACE

ASPHALT

REMOVE/REPLACE

GRASS

REMOVE/REPLACE

ROLL OVER CURB

AND GUTTER

REMOVE/REPLACE

ASPHALT

REMOVE/REPLACE

GRAVEL

REMOVE/REPLACE

ASPHALT

REMOVE/RELOCATE

TRANSFORMER AND BOLLARDS REMOVE/REPLACE

CONCRETE DRIVEWAY

SEE NOTE ON

THE LEFT

REMOVE/REPLACE

SIDEWALK

REMOVE/REPLACE

SIDEWALK

REPLACE

STRIPING TO MATCH

ORIGINAL

REPLACE

STRIPING TO

MATCH ORIGINAL

REMOVE/REPLACE

VERTICAL CURB

PIPE INSTALLATION METHODS

BASE BID:

1. OPEN TRENCH: REMOVE AND REPLACE EXISTING

ASPHALT

ADD ALTERNATE:

2. DIRECTIONAL BORING UNDER STREET

PROTECT

DURING CONSTRUCTION REMOVE/RELOCATE

CABLE PEDESTAL

PROTECT CURB STOP AND

WATER METER DURING

CONSTRUCTION

EXISTING SANITARY LINE

TO BE ABANDONED

(SEE VIEW PORT 2 ON

THE RIGHT)

VIEW PORT 2

SEWER LINE TO BE ABANDONED

EXISTING MANHOLE

TO BE ABANDONED

EXISTING SEWER LINE

TO BE ABANDONED

EXISTING SEWER LINE

TO BE ABANDONED

EXISTING SEWER LINE

TO BE ABANDONED

S

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS SS SS

SS

O H

U O

H U

O H

U O

H U

O H

U

SS

SS

SS

G G G

SSSS

SANITARY MANHOLE 7154

RIM = 4820.78'

INV(S) 4812.43' 8" PVC

INV(W) 4812.28' 8" PVC

S

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS SS SS

SS

O H

U O

H U

O H

U O

H U

O H

U

SS

SS

SS

G G G

SSSS

SANITARY MANHOLE 7154

RIM = 4820.78'

INV(S) 4812.43' 8" PVC

INV(W) 4812.28' 8" PVC

S

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS SS SS

SS

O H

U O

H U

O H

U O

H U

O H

U

SS

SS

SS

G G G

SSSS

SANITARY MANHOLE 7154

RIM = 4820.78'

INV(S) 4812.43' 8" PVC

INV(W) 4812.28' 8" PVC

EXISTING SANITARY LINE TO BE

ABANDONED

EXISTING SANITARY LINE TO BE

ABANDONED

EX1

E X

IS

TI

N G

C O

N D

IT

IO

N

A

N D

D E

M O

LI

TI

O N

M A

P

CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU

DIG, GRADE, OR EXCAVATE FOR THE MARKING OF

UNDERGROUND MEMBER UTILITIES.

CALL UTILITY NOTIFICATION CENTER OF

COLORADO

Know what'sbelow.

before you dig.Call

R

Sheet

V A

S Q

U E

Z S

E W

E R

P R

O

JE

C T

Th es e dr aw in gs a re in st ru m en ts o f s er vi ce pr ov id ed b y

N or th er n En gi ne er in g Se rv ic es In c.

an d ar e no t to b e us ed fo r an y ty pe o f c on st ru ct io n un le ss s ig ne d an d se al ed b y a P ro fe ss io na l E ng in ee r in th e em pl oy o f N or th er n En gi ne er in g Se rv ic es In c.

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

R E

V

IE

W S

E T

30 30

60 90

NORTHNORTHNORTHNORTH

30 30

60 90

20 20

40 60

5.0' MIN

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

G

C

CC

ELEC

BRKR

E

EG

GE

SS

SS

SS

SS

SS

SS

SS

SS

O H

U O

H U

CONTROL

IRR

SS

SS

SS SS SS SS

O H

U O

H U

O H

U O

H U

O H

U

E

SS

SS

SS

SS

G G G G

SSSSSSSS

SS

SS

C

TV

CTV CTV

C

TV

E

EE

E

E

G

C

TV

C

TV

C

TV

C

TV

C

TV

40.59 LF 6" PVC @ 2.04%40.59 LF 6" PVC @ 2.04%40.59 LF 6" PVC @ 2.04%40.59 LF 6" PVC @ 2.04%40.59 LF 6" PVC @ 2.04%45.05 LF 6" PVC @ 1.27% 40.59 LF 6" PVC @ 2.04%45.05 LF 6" PVC @ 1.27% 40.59 LF 6" PVC @ 2.04%45.05 LF 6" PVC @ 1.27%

9.95 LF 4" PVC

CONNECT TO PROPOSED/ADJUST IN THE FIELD

10.58 LF 4" PVC @ 59.85%

CONNECT TO PROPOSED/ADJUST IN THE FIELD

15.39 LF 6" PVC @ 1.36%

4.11 LF 4" PVC

CONNECT TO PROPOSED/ADJUST IN THE FIELD

45.05 LF 6" PVC @ 1.27%

177.74 LF 8" PVC @ 0.56%

CO3

STA 12+22.79

N: 299432.63 E: 597339.43

CO2

STA 12+38.18

N: 299432.69 E: 597354.82

CO1

STA 12+78.77

N: 299432.86 E: 597395.41

INSTALL SANITARY

SEWER CAP

EXISTING SEWER LINE

TO BE ABANDONED

POWERPOLE

PROTECT

POWER

POLE

DURING

INSTALLATION

PIPE INSTALLATION METHODS

BASE BID;

OPEN TRENCH: REMOVE AND

REPLACE EXISTING ASPHALT

ADD ALTERNATE;

DIRECTIONAL BORING UNDER

STREET

SSMH A2

INV. IN=4811.87 (E)

INV. OUT=4811.76 (W)

FG=4817.59

INV. OUT=4810.57 (N)

FG=4815.52

SSMH A2

INV. IN=4811.87 (E)

INV. OUT=4811.76 (W)

FG=4817.59

Structure - (162)

INV. IN=4810.77 (E)

INV. IN=4810.67 (S)

INV. OUT=4810.57 (N)

FG=4815.52

9+50 10+00 11+00 12+00 13+00 14+00

STATION=12+15.26

SOURCE ELEVATION=4817.84

ELECTRIC

STATION=12+61.17

TOP=4820.37

UNKNOWN UTILITY

STATION=12+61.46

TOP= 4818.66

GAS

STATION=12+61.56

TOP= 4819.31

UNKNOWN UTILITY

SS

M

H A

ST

A

+7 7.

R

IM

7.

6±

IN

V.

IN

1.

(E

IN

V.

O U

T

.7

(W

STATION=12+27.16

SOURCE ELEVATION= 4817.81

ELECTRIC

C O

ST

A

+2 2.

R

IM

9.

IN

V.

IN

2.

(N

IN

V.

IN

2.

(E

IN

V.

O U

T

.4

(W

EXISTING

GROUND

C O

ST

A

+3 8.

R

IM

9.

8±

IN

V.

IN

2.

(E

IN

V.

IN

3.

(S

IN

V.

O

U T

.7

(W

STATION=12+28.08

SOURCE ELEVATION=4817.79

ELECTRIC

45.05 LF 6" PVC @ 1.27%

PRIVATE SERVICE LINE

15.39 LF 6" PVC @ 1.36%

PRIVATE SERVICE LINE

40.59 LF 6" PVC @ 2.04%

PRIVATE SERVICE LINE

177.74 LF 8" PVC @ 0.56%

SS

M

H A

ST

A

+0 0.

R

IM

5.

5±

IN

V.

IN

0.

(E

IN

V.

IN

0.

(S

IN

V.

O

U T

.5

(N

Sheet

V A

S Q

U E

Z S

E W

E R

P R

O

JE

C T

Th es e dr aw in gs a re in st ru m en ts o f s er vi ce pr ov id ed b y

N or th er n En gi ne er in g Se rv ic es In c.

an d ar e no t to b e us ed fo r an y ty pe o f c on st ru ct io n un le ss s ig ne d an d se al ed b y a P ro fe ss io na l E ng in ee r in th e em pl oy o f N or th er n En gi ne er in g Se rv ic es In c.

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

R E

V

IE

W S

E T

KEYMAP

SANITARY SEWER LINE A

PROFILE SCALE:

SAN A

NORTH

( IN FEET )

1 inch = ft.

Feet020 20

40 80

SS1

S A

N

IT

A R

Y S

E W

E R

L

IN

E A

P

LA

N

P R

O

FI

LE

EXISTING WATER MAIN

LEGEND:

NOTES:

1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE

APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE

RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL

UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW

CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL

UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN

UNDERGROUND UTILITIES.

2. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF

NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED

WITHIN VEHICLE OR BICYCLE WHEEL PATHS.

3. DRY UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT

LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY

PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.

4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL

STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.

5. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.

6. ALL CLEANOUTS LIDS SHOULD BE INSTALLED AT FINISH GRADE HEIGHT

7. ALL CLEANOUTS SHOULD HAVE A MINIMUM THICKNESS OF 12" AROUND CLEANOUT

WHEN LOCATED IN PAVED ROADWAY

W

PROPOSED SEWER SERVICE

EXISTING SANITARY SEWER SS

PROPOSED SANITARY SEWER

PROJECT BOUNDARY

EXISTING RIGHT OF WAY

EASEMENT LINE

EXISTING MAJOR CONTOUR

EXISTING MINOR CONTOUR

EXISTING CABLE CTV

EXISTING FIBER OPTIC FO

EXISTING OVERHEAD UTILITY OHE

CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU

DIG, GRADE, OR EXCAVATE FOR THE MARKING OF

UNDERGROUND MEMBER UTILITIES.

CALL UTILITY NOTIFICATION CENTER OF

COLORADO

Know what'sbelow.

before you dig.Call

R

ROCK SOCK

PORTABLE CONCRETE WASH AREA

EROSION CONTROL:

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

S

C

GAS

CONTROL

IRR

W

W CS

W

CS

ELEC

CS

W

H Y D

H Y D

S

C.O.

C.O.

SS

SS

SS

SS

SS

SS

X

X

X

O H

U O

H U

O H

U O

H U

O H

U O

H U

O H

U O

H U

CTV CTV CTV CTV CTV CTV

CTV

G G

W W W W W W W W W W W W W W W

W W

W W

W W

G G

G

G G G G G G G G

G

W

W

G G

G

G G

G

E

EEE

E E

EE

W W

G G

G G

G G

G G

W W

W

E

E

W

W W

W W

W

SS

SS

4" W 4" W 4" W 4" W 4" W 4" W 4" W 4" W 4" W

4" W 4" W

ELEC

SSMH A4

INV. OUT=4814.14 (W)

FG=4820.03

SSMH A5

INV. IN=4814.50 (N)

INV. IN=4813.50 (E)

INV. OUT=4812.79 (W)

FG=4819.37

44.21 LF 8" PVC @ 1.45%

296.50 LF 8" PVC @ 0.40%

.0

LF

" P

VC

.4

2%

P CO 1

INV. IN=4816.00 (NW)

INV. OUT=4815.80 (S)

FG=4816.52

EX CO 1

FL ELE. 4816.44

RIM ELE. 4821.89

N: 299274.80 E: 597406.47

EX CO 2

FL ELE. 4817.07

RIM ELE. 4821.71

N: 299189.10 E: 597395.65

SSMH A3

INV. IN=4815.00 (N)

INV. OUT=4814.80 (S)

FG=4820.70

SSMH A6

INV. IN=4811.60 (E)

FG=4818.04

27.83 LF 8" PVC @ 0.72%

30.68 LF 4" PVC @ -3.49%

.3

LF

" P

VC

.5

3%

22.50 LF 4" PVC @ 1.96%

PCO2

STA 13+95.42

N: 299189.07 E: 597426.33

INV. OUT: 4815.20

EXISTING MANHOLE

TO BE ABANDONED

ELECTRIC CONDUIT

TO BE RELOCATED

DURING INSTALLATION

TRANSFORMER

EXISTING 4" WATER MAIN

SEWER LINE C

EXISTING 10" WATER MAIN

EXISTING 2" GAS LINE

SEWER LINE C

SEWER LINE B

EXISTING SEWER LINE

TO BE ABANDONED

EXISTING SEWER LINE

TO BE ABANDONED

SS

SS

SS

SS

SS

SS

ELECTRIC CONDUIT

TO BE RELOCATED

9+75 10+00 11+00 12+00 13+00 14+00 15+00 15+25

STATION=10+01.52

SOURCE ELEVATION=4814.91

ELECTRIC

STATION=10+24.10

SOURCE ELEVATION=4813.68

H20 Service

STATION=11+00.24

SOURCE ELEVATION=4814.78

GAS

STATION=11+07.89

SOURCE ELEVATION=4814.69

ELECTRIC

STATION=11+16.98

SOURCE ELEVATION=4815.42

GAS

STATION=11+91.51

SOURCE ELEVATION=4813.73

H20 Service

STATION=12+19.36

SOURCE ELEVATION=4813.73

GAS

EX CO 2

FL ELE: 4817.07

N: 299189.10 E: 597395.65

INV. IN: 4816.00 (W)

INV. IN: 4815.40 (N)

INV. OUT: 4815.20 (S)

H2O 4" MAIN

APPROX LOCATION

Station=13+06.30 Source Elevation=4813.500

TOP PIPE GAS

Station=13+43.02

Source Elevation=4816.200

SS

M

H A

ST

A

+0 0.

R

IM

8.

0±

IN

V.

IN

1.

(E

IN

V

IN

1.

(S

IN

V O

U T

.3

(N

EXISTING

GROUND

SS

M

H A

ST

A

+0 0.

R

IM

9.

4±

IN

V.

IN

4.

(N

IN

V.

IN

3.

(E

IN

V.

O

U T

.7

(W

±0.68'

±1.7'

SS

M

H A

ST

A

+6 7.

R

IM

0.

7±

IN

V.

IN

5.

(N

IN

V.

O U

T

.8

(S

±0.82'

±1.0 '

±1.3'

EX CO 1

STA 14+93.21

N: 299274.80 E: 597406.47

P CO 1

STA 14+70.72

N: 299264.37 E: 597426.40

INV. IN: 4816.00 (W)

INV. IN: 4815.80 (S)

296.50 LF 8" PVC @ 0.40%

PUBLIC MAIN

30.68 LF

4" PVC

@ 2.61%

71.09 LF 8" PVC @ 0.42%

PRIVATE SERVICE LINE

75.30 LF 8" PVC @ 0.53%

22.50 LF

4" PVC

@ 1.96%

9+50 10+00 10+75

SS

M

H A

ST

A

+4 0.

R

IM

0.

0±

IN

V.

O

U T

.1

(W

SS

M

H A

ST

A

+0

R

IM

9.

4±

IN

V.

IN

4.

(N

IN

V.

IN

3.

(E

IN

V.

O U

T

.7

(W

H20 SERVICE

STA=10+10.41

TOP=4815.34

1.0' APPOXIMATE

EXISTING

GROUND

44.21 LF

8" PVC

@ 1.45%

Sheet

V A

S Q

U…