OMB Approval No. 9000-0009

Authorized for Local Reproduction STANDARD FORM 18 (Rev. 6-95) Previous Edition Not Usable Prescribed by GSA FAR (48 CFR) 53.215-1(a)

REQUEST FOR QUOTATION

(THIS IS NOT AN ORDER)

This RFQ [X ] is [ ] is not a Small Business Set-Aside Page

Of Pages

1. REQUEST NO.

ABL – 90569

2. DATE ISSUED

7/30/2009

3. REQUISITION/PURCHASE REQUEST NO.

4. CERT. FOR NAT. DEF.

UNDER BDSA REG. 2

AND/OR DMS REG.1

RATING

5a. ISSUED BY: U.S. DEPT. OF COMMERCE, NOAA, WESTERN ADMIN SUPPORT CENTER

7600 SAND POINT WAY N.E., SEATTLE WA 98115-6349

6. DELIVER BY (Date) October 15, 2009

5b. FOR INFORMATION CALL (NO COLLECT CALLS)

7. DELIVERY

NAME TELEPHONE NUMBER [ ] FOB DESTINATION [ X ] OTHER (see schedule)

9. DESTINATION SUZANNE JOHNSTON

SUZANNE.JOHNSTON@NOAA.GOV

AREA CODE

NUMBER

789-6061

8. TO:

a. NAME OF CONSIGNEE USDOC/NOAA

NOAA LITTLE PORT WALTER RESEARCH STATION

a. NAME

b. COMPANY

b. STREET ADDRESS

C/O ALASKA MARINE LINES

c. STREET ADDRESS

c. CITY

SITKA

d. CITY

e. STATE

f. ZIP CODE d. STATE

AK

e. ZIP CODE 99835

10. PLEASE FURNISH QUOTATIONS TO

THE ISSUING OFFICE IN BLOCK 5a ON OR BEFORE CLOSE OF BUSINESS (Date)

08/14/2009 3:00 pm AST

IMPORTANT: This is a request for information, and quotations furnished are not offers. If you are unable to quote, please so indicate on this form and return it to the address in Block 5a. This request does not commit the Government to pay any costs incurred in the preparation of the submission of this quotation or to contract for supplies or services. Supplies are of domestic origin unless otherwise indicated by quoter. Any representations and/or certifications attached to this Request for Quotations must be completed by the quoter.

11. SCHEDULE (Include applicable Federal, State and local Taxes)

ITEM NO.

(a)

SUPPLIES/SERVICES

(b)

QUANTITY

(c)

UNIT

(d)

UNIT PRICE

(e)

AMOUNT

(f)

Supply all materials and associated necessary fasteners for the attached roofing and siding project documents

Deliver to address:

Auke Bay Lab, Attn: Jack Christiansen (907-723-4506) C/O Alaska Marine Lines (A.M.L) 5600 W. Marginal Way S.W.

Seattle, WA 98106

MUST ARRIVE IN SITKA, AK

NLT 10/15/2009

FOR ULTIMATE DELIVERY TO AML

SITKA FOR TRANSFER TO M/V EYAK TO

TRANSPORT TO LITTLE PORT WALTER,

AK

LOT

d. CALENDAR DAYS

12. DISCOUNT FOR PROMPT PAYMENT 4

a. 10 CALENDAR DAYS %

b. 20 CALENDAR DAYS %

c. 30 CALENDAR DAYS %

NUMBER

PERCENTAGE

NOTE: Additional provisions and representations [ ] are [ ] are not attached.

13. NAME AND ADDRESS OF QUOTER 14. SIGNATURE OF PERSON AUTHORIZED TO SIGN

QUOTATION

15. DATE OF QUOTATION

a. NAME OF QUOTER

16. SIGNER

b. STREET ADDRESS

b. TELEPHONE a. NAME (type or print)

c. COUNTY

AREA CODE

d. CITY

e. STATE

f. ZIP CODE

c. TITLE (type or print)

NUMBER

QUOTED BY:_____________________ DATE__________________________________

COMPANY NAME:_________________________ email ADDRESS:__________________

PHONE:__________________________ SMALL BUSINESS?_____________________

FAX:_____________________________ TAX ID NUMBER:_______________________

ADDRESS:_______________________

_________________________________ DUNS no._______________________________

_________________________________ CAGE CODE (CCR):_______________________

NAICS CODE_______________________

SIZE STANDARD______ MILLION/YEAR_____________

FAX QUOTE TO SUZANNE JOHNSTON AT (907) 789-6094

Or email suzanne.johnston@noaa.gov.

THE WESTERN REGIONAL ACQUISITION DIVISION, REQUIRES THAT ALL

CONTRACTORS DOING BUSINESS WITH THIS ACQUISITION OFFICE BE REGISTERED

WITH THE CENTRAL CONTRACTOR REGISTRY (CCR) AS OF OCTOBER 1, 2003. AFTER

THIS DATE, NO AWARD CAN BE MADE UNLESS THE VENDER IS REGISTERED IN CCR.

FOR ADDITIONAL INFORMATION AND TO REGISTER IN CCR PLEASE ACCESS THE

FOLLOWING WEB SITE: HTTP://WWW.CCR.GOV. IN ORDER TO REGISTER WITH THE

CCR AND TO BE ELIGIBLE TO RECEIVE AN AWARD FROM THIS ACQUISITION OFFICE,

ALL OFFERORS MUST HAVE A DUN & BRADSTREET NUMBER. A DUN & BRADSTREET

NUMBER MAY BE ACQUIRED FREE OF CHARGE BY CONTACTING DUN &

BRADSTREET ON-LINE AT WWW.DNB.COM/EUPDATE OR BY PHONE AT (800) 333-0505.

ALL CONTRACTORS ARE ALSO REQUIRED TO COMPLETE ONLINE

REPRESENTATIONS AND CERTIFICATIONS AT HTTP://ORCA.BPN.GOV.

NAICS Code applicable to this procurement: 423330 Size standard: 100 employees

Award will only be issued to Vendors/Contractors who:

1. Have a Data Universal Numbering System (DUNS)

2. Is actively registered in the Central Contractor Registration (CCR)

3. Have completed their Online Representations and Certifications Application (ORCA)

According to FAR 52.204-7, to register in CCR, a firm must have a Data Universal Numbering System (DUNS) number. The DUNS Number (DUN & BRADSTREENT #) is assigned by Dun & Bradstreet, Inc. (D&B) to identify unique business entities. A DUNS may be acquired free of charge by going on-line at WWW.DNB.COM/EUPDATE or by phone at (800) 333-0505.

According to the FAR 4.11, prospective vendors must be registered in CCR prior to the award of a contract; basic agreement, basic ordering agreement, or blanket purchase agreement. CCR registration can be done free of charge by going online at WWW.CCR.GOV or you can 1-888-227- 2423 for CCR customer assistance.

Contracts awarded to your firm by the Federal Government containing the clause 52.204-8 Annual Representations and Certifications, require you to create and maintain a profile in ORCA. This can be done online at HTTP://ORCA.BPN.GOV. Instructions on completing your firm's ORCA profile are contained at the ORCA web site:

STATEMENT OF WORK

NOAA Auke Bay Labs Little Port Walter Research Station Warehouse Roofing/Siding Project

Materials

ABL-90569

OBJECTIVE – Upgrade of NOAA’s Little Port Walter Research Station Warehouse roofing and siding.

SPECIFIC TASKS – to include (but not limited to):

• Supply all materials and associated necessary fasteners for the attached roofing and siding project documents

• All panels will be supplied at full lengths specified – no field splicing

• Provide an additional 10% material for all trim and flashing

• Submittal of samples of roofing and siding colors for approval are required with bid submission.

• Prior to shipping the installation contractor will verify material quantity submittals for

NOAA’s approval

Government Provided Please contact Jack Christiansen at 907-723-4506 with questions regarding this RFQ.

Vendor Provided

Vendor to provide all materials per the attached documents plus necessary fasteners and additional lengths as described above. All items to be delivered to Sitka, AK via Alaska Marine Lines with delivery in Sitka to M/V Eyak and clearly marked for delivery to LPW.

PERIOD OF PERFORMANCE

All items are to arrive in Sitka, AK no later than October 15, 2009. Quantity verifications will be made no later than September 15th, 2009 in the event there are minor variations in quantity needed..

INVOICING

In compliance with the Prompt Payment Act, the Financial Management Division will pay an invoice in accordance with the terms set forth in the contracts with vendors if a "proper invoice" is received. A "proper invoice" has:

1. Name of the vendor and an invoice date

2. Purchase order number

3. Description, price and quantity of property and services actually delivered or rendered

4. Payment terms are “Net 30”.

6. Name, title, phone number, and complete mailing address of the responsible official to whom payment is to be made

Invoices are to be submitted to: DOC/NOAA/NMFS Auke Bay Laboratories Ted Stevens Marine Research Institute 17109 Point Lena Loop Rd Juneau, AK 99801

PAYMENT TERMS

This order is net 30 days which means you will receive payment 30 days after a proper invoice is received. Do not expect early payment. If it has been longer than 30 days from the Contracting Officer’s receipt of the invoice, you may request information on when you can expect payment.

INSURANCE COVERAGE

The contractor is solely responsible for their own health, workmen’s compensation and unemployment insurance as well as applicable social security, local, state, and federal taxes.

FEDERAL, STATE, AND LOCAL TAXES

Except as may be otherwise provided in this contract price includes all applicable federal, state, and local taxes and duties in effect on the date of this contract but does not include any taxes from which the Government the Contractor or this transaction is exempt. Upon request of the contractor, the Government shall furnish a tax exemption certificate or similar evidence of exemption with respect to any such tax not included in the contract price pursuant to this clause. For the purpose of this clause, the term "date of this contract" means the date of the contractor's quotation or, if no quotation, the date of this Purchase Order.

The C&A requirements of clause 73 do not apply, and a Security Accreditation Package is not required for this procurement.

NOAA Biological Field Station Little Port Walter, Alaska

Wall and Roof Panel Replacement Material Take-Off Sheets

G:\_Projects\0955\Excel\0935 LPW Material Take-Off 072409.xlsx Page 1

Roof Panel: Snap Seam 16"X2"

Location Panel Length (Feet) No. Panel LF Panel SF Panel

Warehouse S 19.67 45 885 1181 Warehouse N 20.67 45 930 1241 Office S 19.00 21 399 532 Office N 17.50 21 368 490 Wood Warhouse Upper 17.50 21 368 490 Wood Warhouse Lower 17.67 21 371 495 Wood Work Area 20.83 21 437 584 Boom 10.00 16 160 213 Equipment / Open Storage 9.00 44 396 528 Sub totals 4,314 5755

Wall and Roof Panel Replacement Material Take-Off Sheets

G:\_Projects\0955\Excel\0935 LPW Material Take-Off 072409.xlsx Page 2

Soffit Panel: Prestige 12"X1-1/2"

Location Panel Length (Feet) No. Panel LF Panel SF Panel

Warehouse S 3.33 60 200 200

2.33 60 140 186

340 386

Soffit Panel: Trim

Location Panel Length (Feet) Length (FT) Number LF Trim

Warehouse Up Hill N 60 1 60 Warehouse Up Hill S 60 1 60 Subtotal Up Hill Panel Trim 120 Warehouse Up Lower N 60 1 60 Warehouse Up Lower S 60 1 60 Subtotal Lower Panel Trim 120

Wall and Roof Panel Replacement Material Take-Off Sheets

G:\_Projects\0955\Excel\0935 LPW Material Take-Off 072409.xlsx Page 3

Wall Panel: HR-36

Location Panel Length (Feet) No. Panel LF Panel SF Panel

Warehouse S 14.00 20 280 840 Warehouse N 14.00 20 280 840 Warehouse E 15.33 1 15 46

16.33 1 16 49

17.33 1 17 52

18.33 1 18 55

19.33 1 19 58

19.67 1 20 59

Wood Warehouse N 9.50 9 86 257 Wood Warehouse E 11.00 1 11 33

12.00 1 12 36

4.50 1 5 14

5.50 1 6 17

15.00 1 15 45

16.00 1 16 48

6.50 1 7 20

7.50 1 8 23

19.00 1 19 57

20.00 1 20 60

Wood Warehouse W 11.00 1 11 33

12.00 1 12 36

13.00 1 13 39

14.00 1 14 42

4.75 1 5 14

5.33 1 5 16

6.33 1 6 19

7.33 1 7 22

8.33 1 8 25

9.33 1 9 28

10.33 1 10 31

Wall and Roof Panel Replacement Material Take-Off Sheets

G:\_Projects\0955\Excel\0935 LPW Material Take-Off 072409.xlsx Page 4

Wall Panel: HR-36 Continued

Location Panel Length (Feet) No. Panel LF Panel SF Panel

Office E 7.00 1 7 21

8.00 1 8 24

Office S 7.00 1 7 21 Office W 12.00 1 12 36

13.00 1 13 39

14.00 1 14 42

15.00 1 15 45

16.00 1 16 48

16.33 1 16 49

Work Area E 9.00 1 9 27

10.00 1 10 30

11.00 1 11 33

4.00 1 4 12

5.00 1 5 15

13.00 1 13 39

14.00 1 14 42

Work Area S 3.00 7 21 63

9.67 3 29 87

Work Area W 9.00 1 9 27

10.00 1 10 30

11.00 1 11 33

12.00 1 12 36

9.00 1 9 27

3.00 1 3 9

4.00 1 4 12

Work Area W/S 11.00 2 22 66 Boom E 7.67 1 8 23

6.67 1 7 20

5.67 1 6 17

Boom S 5.67 7 40 119 Equipment / Open Storage S 12.83 2 26 77 Equipment / Open Storage W 12.33 17 210 629

6.50 45 293 878

6.50 45 293 878

Sub Total Wall Panel 2,155 6,465

Wall and Roof Panel Replacement Material Take-Off Sheets

G:\_Projects\0955\Excel\0935 LPW Material Take-Off 072409.xlsx Page 5

Metal Warehouse Trim & Misc

Location Discription Length (Ft) Number LF Material

Warehouse Coiling Dr Panel Drip 14 2 28 Panel Jamb 11.00 4.00 44

Warehouse Man Dr Panel Drip 4.00 2.00 8 Panel Jamb 7.00 28.00 196

Warehouse Sill & Closer N/S Sill & Closer 60.00 2.00 120 Warehouse Sill & Closer E Sill & Closer 32.00 1.00 32 Warehouse Panel Cap N/S Panel End & Closer 60.00 2.00 120 Warehouse Rake Rake & Closer 17.00 2.00 34 Warehouse Eave Drip & Flashing 60.00 2.00 120 Warehouse Roof to Wall Transition & Closer 17.00 2.00 34 Warehouse Corner Inside 14.00 2.00 28 Warehouse Corner Outside 14.00 2.00 28 Warehouse Ridge Ridge Vent 60.00 1.00 60 Warehouse Roof Hat Channel 1-1/2 Hat Channels 60.00 22.00 1320 Warehouse Roof Panel Clips Stand off Clips 21.00 22.00 462 Warehouse Roof Purlins S 8" 16 ga "C" Channel Joist 19.33 22.00 425 Warehouse Roof Purlins N 8" 16 ga "C" Channel Joist 20.33 19.00 386 Warehouse Ridge Ventilator 8' Monovent 8.00 1.00 1 each Warehouse Wall Hat Channel S 1-1/2 Hat Channel 8.00 60.00 480 Warehouse Wall Hat Channel N 1-1/2 Hat Channel 8.00 60.00 480 Warehouse Wall Hat Channel E 1-1/2 Hat Channel 10.00 32.00 320 Warehouse Soffit Hat Channel S 1-1/2 Hat Channel 3.00 60.00 180 Warehouse Soffit Hat Channel S 1-1/2 Hat Channel 3.00 60.00 180 Warehouse Roof Insulation S 5" foil Face (UP) 60.00 17.00 1020 Warehouse Roof Insulation N 5" foil Face (UP) 60.00 17.00 1020

Wall and Roof Panel Replacement Material Take-Off Sheets

G:\_Projects\0955\Excel\0935 LPW Material Take-Off 072409.xlsx Page 6

Wood: Office / Warehouse

Location Discription Length (Ft) Number LF Material

Rake Trim Office Roof Rake E/W S Edge Trim and Flashing 19.00 2.00 38 Office Roof Rake E/W n Edge Trim and Flashing 17.50 2.00 35 Warehouse Rake E/W Upper Edge Trim and Flashing 18.50 2.00 37 Warehouse Rake E/W Lower Edge Trim and Flashing 17.50 2.00 35 Work Area Roof Rake E/W Edge Trim and Flashing 20.83 2.00 42 Boom Roof Rake E/W Edge Trim and Flashing 10.50 2.00 21

Eave Trim Office Roof Eave S Edge Drip and Flashing 28.00 1.00 28 Warehouse Roof Eave N Edge Drip and Flashing 28.00 1.00 28 Work Area Roof Eave S Edge Drip and Flashing 28.00 1.00 28 Work Area Roof Eave W Edge Drip and Flashing 7.00 1.00 7 Boom Roof Rake E/W Edge Drip and Flashing 21.00 1.00 21 Equip/Open Storage Eave W Edge Drip and Flashing 53.00 1.00 53 Step Flashing Warehouse Roof Step Flashing Edge Drip & Step Flashing 28.00 2.00 56

Wall to Roof Transition Flashing Office to Work Area S Flashing and Closer 24.50 1.00 25 Work Area to Boom S Flashing and Closer 21.00 1.00 21 Office to Equip/Open Storage Flashing and Closer 59.00 1.00 59

Base Sill & Closer Warehouse E Sill w/ Insert & Panel Closer 10.00 1.00 10 Warehouse N Sill w/ Insert & Panel Closer 24.50 1.00 25 Warehouse W Sill w/ Insert & Panel Closer 13.50 1.00 14 Work Area E Sill w/ Insert & Panel Closer 8.00 1.00 8 Work Area S Sill w/ Insert & Panel Closer 5.50 1.00 6 Work Area W/S Sill w/ Insert & Panel Closer 3.52 1.00 4 Work Area W Sill w/ Insert & Panel Closer 17.67 1.00 18 Boom E Sill w/ Insert & Panel Closer 8.50 1.00 9 Boom S Sill w/ Insert & Panel Closer 20.00 1.00 20 Equip/Open Storage S Sill w/ Insert & Panel Closer 3.17 1.00 3 Equip/Open Storage W Sill w/ Insert & Panel Closer 50.52 1.00 51

Wall and Roof Panel Replacement Material Take-Off Sheets

G:\_Projects\0955\Excel\0935 LPW Material Take-Off 072409.xlsx Page 7

Wood: Office / Warehouse

Location Discription Length (Ft) Number LF Material

Panel Head Office E Head w/ Insert & Pnl Closer 17.00 2.00 34 Office S Head w/ Insert & Pnl Closer 24.50 1.00 25 Office W Head w/ Insert & Pnl Closer 17.00 2.00 34 Warehouse Upper E/W Head w/ Insert & Pnl Closer 18.00 2.00 36 Warehouse Lower E/W Head w/ Insert & Pnl Closer 17.00 2.00 34 Warehousse N Head w/ Insert & Pnl Closer 24.50 1.00 25 Work Area E/W Head w/ Insert & Pnl Closer 17.00 2.00 34 Work Area S Head w/ Insert & Pnl Closer 24.50 1.00 25 Boom E/W Head w/ Insert & Pnl Closer 10.00 2.00 20 Boom S Head w/ Insert & Pnl Closer 20.00 1.00 20 Equip/Open Storage W Head w/ Insert & Pnl Closer 56.00 1.00 56 Equip/Open Storage S Head w/ Insert & Pnl Closer 8.00 1.00 8 Equip/Open Storage N Head w/ Insert & Pnl Closer 8.00 1.00 8

Window Trim Office Drip Head Drip w/ Closer 6.67 3.00 20 Office Jamb Panel Jamb 4.00 6.00 24 Office Sill Sill 6.33 3.00 19 Office Drip Head Drip w/ Closer 4.67 3.00 14 Office Jamb Panel Jamb 4.00 6.00 24 Office Sill Sill 4.33 3.00 13 Office Drip Head Drip w/ Closer 2.67 1.00 3 Office Jamb Panel Jamb 4.00 2.00 8 Office Sill Sill 2.33 1.00 2 Warehouse Drip Head Drip w/ Closer 3.67 1.00 4 Warehouse Jamb Panel Jamb 3.00 2.00 6 Warehouse Sill Sill 3.33 1.00 3 Work Area Drip Head Drip w/ Closer 8.67 2.00 17 Work Area Jamb Panel Jamb 2.00 4.00 8 Work Area Sill Sill 8.33 2.00 17 Work Area Drip Head Drip w/ Closer 5.67 2.00 11 Work Area Jamb Panel Jamb 4.50 4.00 18 Work Area Sill Sill 5.33 2.00 11 Work Area Drip Head Drip w/ Closer 2.67 2.00 5 Work Area Jamb Panel Jamb 4.50 4.00 18 Work Area Sill Sill 2.33 2.00 5

Wall and Roof Panel Replacement Material Take-Off Sheets

G:\_Projects\0955\Excel\0935 LPW Material Take-Off 072409.xlsx Page 8

Wood: Office / Warehouse

Location Discription Length (Ft) Number LF Material

Door / Opening Trim Warehouse Coiling Door Drip Drip & Closer 10.67 1.00 11 Warehouse Coiling Door Jamb Panel Jamb 11.33 2.00 23 Warehouse Coiling Door Drip Drip & Closer 10.67 1.00 11 Warehouse Coiling Door Jamb Panel Jamb 8.00 2.00 16 Warehouse Opening Drip Drip & Closer 3.67 1.00 4 Warehouse Opening Jamb Panel Jamb 7.00 2.00 14 Warehouse Opening Drip Drip & Closer 11.67 1.00 12 Warehouse Opening Jamb Panel Jamb 7.50 2.00 15 Warehouse Stair Opening Drip Drip & Closer 4.67 1.00 5 Warehouse Stair Opening Jamb Panel Jamb 13.00 1.00 13 Boom Opening Drip W Drip & Closer 7.00 2.00 14 Boom Opening Jamb W Panel Jamb 5.00 3.00 15

Outside Corner Trim Office W Panel Outside Corner 11.00 1.00 11 Office E Panel Outside Corner 6.00 1.00 6 Warehouse E/W Panel Outside Corner 9.00 2.00 18 Work Area E Panel Outside Corner 8.67 2.00 17 Work Area W Panel Outside Corner 8.00 2.00 16 Equip/Open Storage Panel Outside Corner 11.50 2.00 23

Inside Corner Trim Work Area E Panel Inside Corner 14.00 1.00 14 Work Area E Panel Inside Corner 8.67 1.00 9 Work Area W Panel Inside Corner 10.00 1.00 10 Work Area W Panel Inside Corner 8.50 1.00 9

Wall and Roof Panel Replacement Material Take-Off Sheets

G:\_Projects\0955\Excel\0935 LPW Material Take-Off 072409.xlsx Page 9

Wood: Office / Warehouse

Location Width (Ft) Height (FT) SF Material

30 lb Roofing Felt Office S 28.00 20.00 560 Office/Warehouse N 28.00 55.00 1540 Work Area 21.00 26.00 546 Boom 21.00 10.00 210 Equip/Open Storage 9.00 56.00 504 Total Roofing Felt 3360

Tyvek for Plywood Sheathing North 24.50 9.00 221 East 70.00 20.00 1400 South 24.50 16.00 392 West 92.00 20.00 1840 Total Tyvek 3853

NOAA Biological Field Station COLD-FORMED METAL FRAMING Wall and Roof Panel Replacement 054000 - 1

SECTION 054000 - COLD-FORMED METAL FRAMING

PART 1 - GENERAL

1.1 SUMMARY

A. This Section includes the following:

1. Exterior load-bearing framing.

1.2 PERFORMANCE REQUIREMENTS

A. Structural Performance: Provide cold-formed metal framing capable of withstanding design loads within limits and under conditions indicated.

1. Design Loads: As follows:

a. Snow Loads: 240 lb snow ground load

b. Wind Loads: 120 mph exposure D

1.3 SUBMITTALS

A. Product Data: For each type of product and accessory indicated.

B. Qualification data.

C. Product test reports.

D. Research/evaluation reports.

1.4 QUALITY ASSURANCE

A. Product Tests: Mill certificates or data from a qualified independent testing agency indicating steel sheet complies with requirements.

PART 2 - PRODUCTS

2.1 MATERIALS

A. Steel Sheet: ASTM A 1003/A 1003M, Structural Grade, Type H, metallic coated, of grade and coating weight as follows:

1. Grade: ST33H (ST230H).

2. Coating: G90 (Z275) or equivalent.

3. Sizes and configurations: As shown.

Wall and Roof Panel Replacement 054000 - 2

2.2 FRAMING ACCESSORIES

A. Fabricate steel-framing accessories from steel sheet, ASTM A 1003/A 1003M, Structural Grade, Type H, metallic coated, of same grade and coating weight used for framing members, unless otherwise indicated.

B. Steel Shapes and Clips: ASTM A 36/A 36M, zinc coated by hot-dip process according to

ASTM A 123/A 123M.

C. Mechanical Fasteners: ASTM C 1513, corrosion-resistant-coated, self-drilling, self-tapping steel drill screws.

1. Head Type: Low-profile head beneath sheathing, manufacturer's standard elsewhere.

2.3 MISCELLANEOUS MATERIALS

A. Galvanizing Repair Paint: SSPC-Paint 20 or DOD-P-21035.

B. Sealer Gaskets: Closed-cell neoprene foam, 1/4 inch (6.4 mm) thick, selected from manufacturer's standard widths to match width of bottom track or rim track members.

PART 3 - EXECUTION

3.1 PREPARATION

A. Examine existing roof and walls and verify lines and levels indicated. Provide additional shims or additional framing as required to align surfaces. Do not proceed until substrate requirements for metal roof are achieved.

3.2 INSTALLATION, GENERAL

A. Install cold-formed metal framing according to AISI's "Standard for Cold-Formed Steel Framing - General Provisions" and to manufacturer's written instructions unless more stringent requirements are indicated.

B. Install cold-formed metal framing and accessories plumb, square, and true to line, and with connections securely fastened.

C. Install framing members in one-piece lengths.

D. Install temporary bracing and supports to secure framing and support loads comparable in intensity to those for which structure was designed. Maintain braces and supports in place, undisturbed, until entire integrated supporting structure has been completed and permanent connections to framing are secured.

E. Install insulation, specified in Division 07 Section "Thermal Insulation," in built-up exterior framing members, such as headers, sills, boxed joists, and multiple studs at openings, that are inaccessible on completion of framing work.

Wall and Roof Panel Replacement 054000 - 3

F. Fasten hole reinforcing plate over web penetrations that exceed size of manufacturer's standard punched openings.

G. Erection Tolerances: Install cold-formed metal framing level, plumb, and true to line to a maximum allowable tolerance variation of 1/8 inch in 10 feet (1:960) and as follows:

1. Space individual framing members no more than plus or minus 1/8 inch (3 mm) from plan location. Cumulative error shall not exceed minimum fastening requirements of sheathing or other finishing materials.

3.3 REPAIRS AND PROTECTION

A. Galvanizing Repairs: Prepare and repair damaged galvanized coatings on fabricated and installed cold-formed metal framing with galvanized repair paint according to ASTM A 780 and manufacturer's written instructions.

B. Provide final protection and maintain conditions, in a manner acceptable to manufacturer and Installer, that ensure that cold-formed metal framing is without damage or deterioration at time of Substantial Completion.

END OF SECTION 054000

NOAA Biological Field Station THERMAL INSULATION Wall and Roof Panel Replacement 072100 - 1

SECTION 072100 - THERMAL INSULATION

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Glass-fiber blanket insulation.

1.2 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Product test reports.

C. Research/evaluation reports.

PART 2 - PRODUCTS

2.1 GLASS-FIBER BLANKET INSULATION

A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

1. CertainTeed Corporation.

2. Guardian Building Products, Inc.

3. Johns Manville.

4. Knauf Insulation.

5. Owens Corning.

B. Polypropylene-Scrim-Kraft-Faced, Glass-Fiber Blanket Insulation: ASTM C 665, Type II (non-reflective faced), Class A (faced surface with a flame-spread index of 25 or less); Category 1 (membrane is a vapor barrier).

C. Eave Ventilation Troughs: Preformed, rigid fiberboard or plastic sheets designed and sized to fit between roof framing members and to provide cross ventilation between insulated attic spaces and vented eaves.

PART 3 - EXECUTION

3.1 INSTALLATION, GENERAL

A. Comply with insulation manufacturer's written instructions applicable to products and applications indicated.

NOAA Biological Field Station THERMAL INSULATION Wall and Roof Panel Replacement 072100 - 2

B. Install insulation that is undamaged, dry, and unsoiled and that has not been left exposed to ice, rain, or snow at any time.

C. Extend insulation to envelop entire area to be insulated. Cut and fit tightly around obstructions and fill voids with insulation. Remove projections that interfere with placement.

D. Provide sizes to fit applications indicated and selected from manufacturer's standard thicknesses, widths, and lengths. Apply single layer of insulation units to produce thickness indicated unless multiple layers are otherwise shown or required to make up total thickness.

3.2 INSTALLATION OF INSULATION FOR FRAMED CONSTRUCTION

A. Apply insulation units to substrates by method indicated, complying with manufacturer's written instructions. If no specific method is indicated, bond units to substrate with adhesive or use mechanical anchorage to provide permanent placement and support of units.

B. Glass-Fiber Insulation: Install in cavities formed by framing members according to the following requirements:

1. Use insulation widths and lengths that fill the cavities formed by framing members to extent shown. If more than one length is required to fill the cavities, provide lengths that will produce a snug fit between ends.

2. Place insulation in cavities formed by framing members to produce a friction fit between edges of insulation and adjoining framing members.

3. Install eave ventilation troughs between roof framing members in insulated attic spaces at vented eaves.

END OF SECTION 072100

Copyright 2008 AIA MASTERSPEC Short Form 11/08

NOAA Biological Field Station WEATHER BARRIERS Wall and Roof Panel Replacement 072500 - 1

SECTION 072500 - WEATHER BARRIERS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Building paper.

2. Building wrap.

3. Flexible flashing.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

1.3 INFORMATIONAL SUBMITTALS

A. Evaluation Reports: For water-resistive barrier and flexible flashing, from ICC-ES.

PART 2 - PRODUCTS

2.1 WATER-RESISTIVE BARRIER

A. Building Paper for application on plywood roof deck: ASTM D 226, Type II (No. 30 asphalt-saturated organic felt), unperforated.

B. Building Wrap for application on plywood wall sheathing: ASTM E 1677, Type I air barrier;

with flame-spread and smoke-developed indexes of less than 25 and 450, respectively, when tested according to ASTM E 84; UV stabilized; and acceptable to authorities having jurisdiction.

1. Products: Subject to compliance with requirements, provide one of the following:

a. Dow Chemical Company (The); Styrofoam Weathermate Plus Brand Housewrap.

b. DuPont (E. I. du Pont de Nemours and Company); Tyvek CommercialWrap.

c. Ludlow Coated Products; Barricade Building Wrap.

d. Pactiv, Inc.; GreenGuard Ultra Wrap.

e. Raven Industries Inc.; Fortress Pro Weather Protective Barrier.

f. Reemay, Inc.; Typar HouseWrap.

2. Water-Vapor Permeance: Not less than 50 g through 1 sq. m of surface in 24 hours per ASTM E 96/E 96M, Desiccant Method (Procedure A).

Wall and Roof Panel Replacement 072500 - 2

C. Building-Wrap Tape: Pressure-sensitive plastic tape recommended by building-wrap manufacturer for sealing joints and penetrations in building wrap.

2.2 MISCELLANEOUS MATERIALS

A. Flexible Flashing: Self-adhesive butyl rubber or rubberized-asphalt compound, bonded to a high-density polyethylene film, aluminum foil, or spunbonded polyolefin to produce an overall thickness of not less than 0.025 inch (0.6 mm).

1. Products: Subject to compliance with requirements, provide one of the following:

a. DuPont (E. I. du Pont de Nemours and Company); DuPont Flashing Tape.

b. Grace Construction Products, a unit of W. R. Grace & Co. - Conn.; Vycor Butyl

Self Adhered Flashing.

c. Protecto Wrap Company; BT-25 XL.

d. Raven Industries Inc.; Fortress Flashshield.

e. Advanced Building Products Inc.; Wind-o-wrap.

f. Carlisle Coatings & Waterproofing; CCW-705-TWF Thru-Wall Flashing.

g. Fiberweb, Clark Hammerbeam Corp.; Aquaflash 500.

h. Fortifiber Building Systems Group; Fortiflash 40.

i. Grace Construction Products, a unit of W. R. Grace & Co. - Conn.; Vycor V40

Self-Adhered Flashing.

j. MFM Building Products Corp.; Window Wrap.

k. Sandell Manufacturing Co., Inc.; Presto-Seal.

PART 3 - EXECUTION

3.1 WATER-RESISTIVE BARRIER INSTALLATION

A. Cover sheathing with water-resistive barrier as follows:

1. Cut back barrier 1/2 inch (13 mm) on each side of the break in supporting members at expansion- or control-joint locations.

2. Apply barrier to cover vertical flashing with a minimum 4-inch (100-mm) overlap unless otherwise indicated.

B. Building Paper: Apply horizontally with a 2-inch (50-mm) overlap and a 6-inch (150-mm) end lap; fasten to sheathing with galvanized staples or roofing nails.

C. Building Wrap: Comply with manufacturer's written instructions.

1. Seal seams, edges, fasteners, and penetrations with tape.

2. Extend into jambs of openings and seal corners with tape.

Wall and Roof Panel Replacement 072500 - 3

3.2 FLEXIBLE FLASHING INSTALLATION

A. Apply flexible flashing: at all door, window and framed openings in walls; at all changes in roof plane; at roof perimeter to 36” inside wall line; where indicated to comply with manufacturer's written instructions.

1. Lap seams and junctures with other materials at least 4 inches (100 mm) except that at flashing flanges of other construction, laps need not exceed flange width.

2. Lap flashing over water-resistive barrier at bottom and sides of openings.

3. Lap water-resistive barrier over flashing at heads of openings.

END OF SECTION 072500

NOAA Biological Field Station METAL ROOF PANELS Wall and Roof Panel Replacement 074113 - 1

SECTION 074113 - METAL ROOF PANELS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Standing-seam metal roof panels.

2. Metal soffit panels.

1.2 PERFORMANCE REQUIREMENTS

A. Hydrostatic-Head Resistance: No water penetration when tested according to ASTM E 2140.

B. Structural Performance: Provide metal roof panel assemblies capable of withstanding the effects of gravity loads and the following loads and stresses within limits and under conditions indicated, based on testing according to ASTM E 1592:

1. Wind Loads resulting from design wind load at site, prescribed as 120 mph exposure D, as defined in the 2006 International Building Code.

2. Snow Loads: 240 psf ground snow load.

3. Deflection Limits: Metal roof panel assemblies shall withstand wind and snow loads with vertical deflections no greater than 1/180 of the span.

1.3 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Shop Drawings: Show fabrication and installation layouts of metal roof panels; details of edge conditions, side-seam and endlap joints, panel profiles, corners, anchorages, trim, flashings, closures, and accessories; and special details. Distinguish between factory- and field-assembled work.

C. Samples: For each type of exposed finish required.

D. Delegated-Design Submittal: For metal roof panel assembly indicated to comply with performance requirements and design criteria, including analysis data and calculations signed and sealed by the qualified professional engineer responsible for their preparation.

E. Coordination Drawings: Roof plans, drawn to scale, based on drawings provided in project manual, and as verified in the field by the roof manufacturer.

F. Manufacturer Certificates: Signed by manufacturer certifying that roof panels comply with energy performance requirements specified in "Performance Requirements" Article.

1. Submit evidence of meeting performance requirements.

Wall and Roof Panel Replacement 074113 - 2

G. Product test reports.

H. Field quality-control reports.

I. Maintenance data.

J. Warranties: Samples of special warranties.

1.4 QUALITY ASSURANCE

A. Installer Qualifications: An employer of workers trained and approved by manufacturer.

B. Fire-Resistance Ratings: Where indicated, provide metal roof panels identical to those of assemblies tested for fire resistance per ASTM E 119 by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.

1. Combustion Characteristics: ASTM E 136.

C. Preinstallation Conference: Conduct conference at location directed by Owner.

1.5 WARRANTY

A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace metal roof panel assemblies that fail in materials or workmanship within specified warranty period.

1. Warranty Period: Two years from date of Substantial Completion.

B. Special Warranty on Panel Finishes: Manufacturer's standard form in which manufacturer agrees to repair finish or replace metal roof panels that show evidence of deterioration of factory-applied finishes within specified warranty period.

1. Finish Warranty Period: 20 years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 PANEL MATERIALS

A. Metallic-Coated Steel Sheet: Restricted flatness steel sheet metallic coated by the hot-dip process and prepainted by the coil-coating process to comply with ASTM A 755/A 755M.

1. Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A 792/A 792M, Class AZ50 coating designation, Grade 40 (Class AZM150 coating designation, Grade 275); structural quality.

2. Surface: Smooth, flat finish.

3. Exposed Coil-Coated Finish:

a. 3-Coat Fluoropolymer: AAMA 621. Fluoropolymer finish containing not less than 70 percent PVDF resin by weight in both color coat and clear topcoat.

Wall and Roof Panel Replacement 074113 - 3

4. Concealed Finish: Manufacturer's standard white or light-colored acrylic or polyester backer finish.

B. Panel Sealants:

1. Sealant Tape: Pressure-sensitive, 100 percent solids, gray polyisobutylene compound sealant tape with release-paper backing; 1/2 inch (13 mm) wide and 1/8 inch (3 mm) thick.

2. Joint Sealant: ASTM C 920; as recommended in writing by metal roof panel manufacturer.

3. Butyl-Rubber-Based, Solvent-Release Sealant: ASTM C 1311.

2.2 FIELD-INSTALLED THERMAL INSULATION

A. Refer to Division 07 Section "Thermal Insulation."

2.3 UNDERLAYMENT MATERIALS

A. Refer to Division 07 Section “Weather Barriers”.

B. Slip Sheet: Manufacturer's recommended slip sheet, of type required for application.

2.4 MISCELLANEOUS METAL FRAMING

A. Refer to Division 05 Section “Cold Formed Metal Framing”.

2.5 MISCELLANEOUS MATERIALS

A. Panel Fasteners: Self-tapping screws, bolts, nuts, self-locking rivets and bolts, end-welded studs, and other suitable fasteners designed to withstand design loads. Provide exposed fasteners with heads matching color of metal roof panels by means of plastic caps or factory-applied coating. Provide EPDM, PVC, or neoprene sealing washers.

B. Bituminous Coating: Cold-applied asphalt mastic, SSPC-Paint 12, compounded for 15-mil (0.4-mm) dry film thickness per coat. Provide inert-type noncorrosive compound free of asbestos fibers, sulfur components, and other deleterious impurities.

2.6 STANDING-SEAM METAL ROOF PANELS

A. General: Provide factory-formed metal roof panels designed to be installed by lapping and interconnecting raised side edges of adjacent panels with joint type indicated and mechanically attaching panels to supports using concealed clips in side laps. Include clips, cleats, pressure plates, and accessories required for weathertight installation.

1. Steel Panel Systems: Unless more stringent requirements are indicated, comply with

ASTM E 1514.

Wall and Roof Panel Replacement 074113 - 4

2. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on Drawings or comparable product by one of the following:

a. AEP-Span.

b. Architectural Building Components.

c. Architectural Metal Systems.

d. Architectural Roofing and Siding, Inc.

e. ATAS International, Inc.

f. Berridge Manufacturing Company.

g. Butler Manufacturing; a BlueScope Steel company.

h. CENTRIA Architectural Systems.

i. Copper Sales, Inc.

j. Dimensional Metals, Inc.

k. Englert, Inc.

l. Fabral.

m. Flexospan Steel Buildings, Inc.

n. Galvamet; Galvacer Building Systems.

o. IMETCO.

p. Integris Metals.

q. MBCI; a division of NCI Building Systems, L. P.

r. McElroy Metal, Inc.

s. Merchant & Evans.

t. Metal-Fab Manufacturing, LLC.

u. Metal Sales Manufacturing Corporation.

v. Metecno-Morin; Division of Metecno Inc.

w. Modern Metal Systems, Inc.

x. Petersen Aluminum Corporation.

y. Steelox Systems, L.L.C.

z. Ultra Seam Incorporated.

aa. United Steel Deck Inc.; Subsidiary of Bouras Industries Inc.

bb. VICWEST; Div. of Jenisys Engineered Products.

3. Profile: Vertical-rib, seamed-joint, as indicated on Drawings.

4. Material: Aluminum-Zinc Alloy-Coated Steel Sheet: thickness and configuration shown.

a. Exterior Finish: 3-coat fluoropolymer.

b. Color: As selected by Architect from manufacturer's full range.

5. Clips: Floating to accommodate thermal movement.

a. Material: Metallic coated steel.

6. Joint Type: As standard with manufacturer.

7. Panel Coverage: 16”.

8. Panel Height: 2”.

Wall and Roof Panel Replacement 074113 - 5

2.7 METAL SOFFIT PANELS

A. General: Provide factory-formed perforated metal soffit panels designed to be installed by lapping and interconnecting side edges of adjacent panels and mechanically attaching through panel to supports using concealed fasteners in side laps. Include accessories required for weathertight installation.

B. Metal Soffit Panels: Match profile and material of metal roof panels.

1. Finish: Match finish and color of metal roof panels.

2. Sealant: Factory applied within interlocking joint.

3. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on Drawings or comparable product by one of the following:

a. AEP-Span.

b. Architectural Building Components.

c. ATAS International, Inc.

d. Berridge Manufacturing Company.

e. CENTRIA Architectural Systems.

f. Cheney Flashing Company.

g. Copper Sales, Inc.

h. Dimensional Metals, Inc.

i. Englert, Inc.

j. Fabral.

k. IMETCO.

l. MBCI; a division of NCI Building Systems, L. P.

m. McElroy Metal, Inc.

n. Merchant & Evans.

o. Metal-Fab Manufacturing, LLC.

p. Metal Sales Manufacturing Corporation.

q. Petersen Aluminum Corporation.

r. Ultra Seam Incorporated.

4. Profile: as indicated on Drawings.

5. Material: Same material, finish, and color as metal roof panels.

2.8 ACCESSORIES

A. Roof Panel Accessories: Provide components approved by roof panel manufacturer and as required for a complete metal roof panel assembly including trim, copings, fasciae, corner units, ridge closures, clips, flashings, sealants, gaskets, fillers, closure strips, and similar items. Match material and finish of metal roof panels unless otherwise indicated.

1. Closures: Provide closures at eaves and ridges, fabricated of same metal as metal roof panels.

2. Closure Strips: Closed-cell, expanded, cellular, rubber or crosslinked, polyolefin-foam or closed-cell laminated polyethylene; minimum 1-inch- (25-mm-) thick, flexible closure strips; cut or premolded to match metal roof panel profile. Provide closure strips where indicated or necessary to ensure weathertight construction.

Wall and Roof Panel Replacement 074113 - 6

3. Backing Plates: Provide metal backing plates at panel end splices, fabricated from material recommended by manufacturer.

B. Flashing and Trim: Formed from same material as roof panels, prepainted with coil coating, minimum 24 gage thick. Provide flashing and trim as required to seal against weather and to provide finished appearance. Locations include, but are not limited to, eaves, rakes, corners, bases, framed openings, vented and non ventilated ridges, fasciae, and fillers. Finish flashing and trim with same finish system as adjacent metal roof panels.

1. Include 2 part flashing to wrap existing wood fascias.

2.9 FABRICATION

A. Fabricate and finish metal roof panels and accessories at the factory to greatest extent possible, by manufacturer's standard procedures and processes and as necessary to fulfill indicated performance requirements. Comply with indicated profiles and with dimensional and structural requirements.

B. Provide panel profile, including major ribs and intermediate stiffening ribs, if any, for full length of panel.

C. Fabricate metal roof panel side laps with factory-installed captive gaskets or separator strips that provide a tight seal and prevent metal-to-metal contact, in a manner that will seal weathertight and minimize noise from movements within panel assembly.

D. Sheet Metal Accessories: Fabricate flashing and trim to comply with recommendations in SMACNA's "Architectural Sheet Metal Manual" that apply to the design, dimensions, metal, and other characteristics of item indicated.

PART 3 - EXECUTION

3.1 PREPARATION

A. Substrate Board: Examine existing roof deck on entire roof surface. Correct as required to meet roof manufacturer requirements.

B. Miscellaneous Framing: Install subpurlins, eave angles, furring, and other miscellaneous roof panel support members and anchorage according to metal roof panel manufacturer's written instructions.

3.2 UNDERLAYMENT INSTALLATION

A. Self-Adhering Sheet Underlayment: Apply primer if required by manufacturer. Comply with temperature restrictions of underlayment manufacturer for installation. Apply at locations indicated, wrinkle free, in shingle fashion to shed water, and with end laps of not less than 6 inches (150 mm) staggered 24 inches (600 mm) between courses. Overlap side edges not less than 3-1/2 inches (90 mm). Roll laps with roller. Cover underlayment within 14 days.

Wall and Roof Panel Replacement 074113 - 7

B. Felt Underlayment: Apply at locations indicated on Drawings, in shingle fashion to shed water, and with lapped joints of not less than 2 inches (50 mm).

C. Apply slip sheet over underlayment before installing metal roof panels.

D. Install flashings to cover underlayment to comply with requirements specified in Division 07 Section "Sheet Metal Flashing and Trim."

3.3 THERMAL INSULATION INSTALLATION

A. Blanket Insulation: Install insulation concurrently with metal roof panel installation, in thickness indicated to cover entire roof, according to manufacturer's written instructions and as follows:

1. Set vapor-retarder-faced units with vapor retarder to warm side of construction unless otherwise indicated. Do not obstruct ventilation spaces.

2. Tape joints and ruptures in vapor retarder and seal each continuous area of insulation to surrounding construction to ensure airtight installation.

3. Install blankets straight and true in one-piece lengths with both sets of facing tabs sealed.

4. Retainer Strips: Install retainer strips at each longitudinal insulation joint, straight and taut, nesting with secondary framing to hold insulation in place.

3.4 METAL ROOF PANEL INSTALLATION

A. Standing-Seam Metal Roof Panels: Fasten metal roof panels to supports with concealed clips at each standing-seam joint at location, spacing, and with fasteners recommended by manufacturer.

1. Install clips to supports with self-tapping fasteners.

2. Install pressure plates at locations indicated in manufacturer's written installation instructions.

3. Seamed Joint: Crimp standing seams with manufacturer-approved, motorized seamer tool so clip, metal roof panel, and factory-applied sealant are completely engaged.

B. Metal Soffit Panels: Provide metal soffit panels full width of soffits. Install panels perpendicular to support framing.

1. Flash and seal panels with weather closures where metal soffit panels meet walls and at perimeter of all openings.

3.5 ACCESSORY INSTALLATION

A. General: Install accessories with positive anchorage to building and weathertight mounting and provide for thermal expansion. Coordinate installation with flashings and other components.

1. Install components required for a complete metal roof panel assembly including trim, copings, ridge closures, seam covers, flashings, sealants, gaskets, fillers, closure strips, and similar items.

Wall and Roof Panel Replacement 074113 - 8

2. Flashing and Trim: Comply with performance requirements, manufacturer's written installation instructions, and SMACNA's "Architectural Sheet Metal Manual." Provide concealed fasteners where possible, and set units true to line and level as indicated.

Install work with laps, joints, and seams that will be permanently watertight and weather resistant.

3.6 CLEANING

A. Remove temporary protective coverings and strippable films, if any, as metal roof panels are installed unless otherwise indicated in manufacturer's written installation instructions. On completion of metal roof panel installation, clean finished surfaces as recommended by metal roof panel manufacturer. Maintain in a clean condition during construction.

END OF SECTION 074113

NOAA Biological Field Station METAL WALL PANELS Wall and Roof Panel Replacement 074213 - 1

SECTION 074213 - METAL WALL PANELS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Exposed-fastener, lap-seam metal wall panels.

1.2 PERFORMANCE REQUIREMENTS

A. Structural Performance: Provide metal wall panel assemblies capable of withstanding the effects the following loads and stresses within limits and under conditions indicated, based on testing according to ASTM E 1592:

1. Wind Loads: Determine loads based on the minimum design wind pressures as determined using design wind speed of 120 mph exposure D as defined by 2006 International Building Code.

2. Deflection Limits: Metal wall panel assemblies shall withstand wind loads with horizontal deflections no greater than 1/180 of the span.

1.3 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Shop Drawings: Show fabrication and installation layouts of metal wall panels; details of edge conditions, joints, panel profiles, corners, anchorages, attachment system, trim, flashings, closures, and accessories; and special details. Distinguish between factory-, shop- and field-assembled work.

C. Samples: For each type of exposed finish required.

D. Coordination Drawings: Exterior elevations drawn to scale and coordinating penetrations and wall-mounted items.

E. Product test reports.

F. Maintenance data.

G. Warranties: Samples of special warranties.

1.4 QUALITY ASSURANCE

A. Installer Qualifications: An employer of workers trained and approved by manufacturer.

Wall and Roof Panel Replacement 074213 - 2

1.5 WARRANTY

A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of metal wall panel assemblies that fail in materials or workmanship within specified warranty period.

1. Warranty Period: Two years from date of Substantial Completion.

B. Special Warranty on Panel Finishes: Manufacturer's standard form in which manufacturer agrees to repair finish or replace metal wall panels that show evidence of deterioration of factory-applied finishes within specified warranty period.

1. Finish Warranty Period: 20 years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 PANEL MATERIALS

A. Metallic-Coated Steel Sheet: Restricted flatness steel sheet metallic coated by the hot-dip process and prepainted by the coil-coating process to comply with ASTM A 755/A 755M.

1. Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A 792/A 792M, Class AZ50 coating designation, Grade 40 (Class AZM150 coating designation, Grade 275); structural quality.

2. Surface: Smooth, flat finish.

3. Exposed Coil-Coated Finish:

a. 3-Coat Fluoropolymer: AAMA 621. Fluoropolymer finish containing not less than 70 percent PVDF resin by weight in both color coat and clear topcoat.

4. Concealed Finish: Manufacturer's standard white or light-colored acrylic or polyester backer finish.

B. Panel Sealants:

1. Sealant Tape: Pressure-sensitive, 100 percent solids, gray polyisobutylene compound sealant tape with release-paper backing; 1/2 inch (13 mm) wide and 1/8 inch (3 mm) thick.

2. Joint Sealant: ASTM C 920 as recommended in writing by metal wall panel manufacturer.

3. Butyl-Rubber-Based, Solvent-Release Sealant: ASTM C 1311.

2.2 MISCELLANEOUS METAL FRAMING

A. Refer to Division 05 Section “Light Gage Metal Framing”, and drawings for locations, sizes and configurations.

Wall and Roof Panel Replacement 074213 - 3

2.3 MISCELLANEOUS MATERIALS

A. Panel Fasteners: Self-tapping screws, bolts, nuts, self-locking rivets and bolts, end-welded studs, and other suitable fasteners designed to withstand design loads. Provide exposed fasteners with heads matching color of metal wall panels by means of plastic caps or factory-applied coating. Provide EPDM, PVC, or neoprene sealing washers.

2.4 EXPOSED-FASTENER, LAP-SEAM METAL WALL PANELS

A. Provide factory-formed metal wall panels designed to be field assembled by lapping side edges of adjacent panels and mechanically attaching panels to supports using exposed fasteners in side laps. Include accessories required for weathertight installation.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on Drawings or comparable product by one of the following:

a. AEP-Span.

b. Alcoa Architectural Products (USA).

c. Architectural Metal Systems.

d. ATAS International, Inc.

e. Berridge Manufacturing Company.

f. Butler Manufacturing Company

g. CENTRIA Architectural Systems.

h. Copper Sales, Inc.

i. Englert, Inc.

j. Fabral.

k. Flexospan Steel Buildings, Inc.

l. Galvamet.

m. Industrial Building Panels.

n. MBCI; Div. of NCI Building Systems.

o. McElroy Metal, Inc.

p. Metal Sales Manufacturing Corporation.

q. Metecno-Morin.

r. Petersen Aluminum Corporation.

s. Steelox Systems, L.L.C.

t. United Steel Deck, Inc.; Subsidiary of Bouras Industries Inc.

u. VICWEST; Div. of Jenisys Engineered Products.

2. Profile: Tapered rib.

3. Material: Aluminum-zinc alloy-coated steel sheet, thickness as shown.

a. Exterior Finish: 3-coat fluoropolymer.

b. Color: As selected by Architect from manufacturer's full range.

4. Major-Rib Spacing: 7-3/16”

5. Panel Coverage: 36 inches

6. Panel Height: 1-1/2”

Wall and Roof Panel Replacement 074213 - 4

2.5 ACCESSORIES

A. Wall Panel Accessories: Provide components required for a complete metal wall panel assembly including trim, copings, fasciae, mullions, sills, corner units, clips, flashings, sealants, gaskets, fillers, closure strips, and similar items. Match material and finish of metal wall panels, unless otherwise indicated.

1. Closures: Provide closures at eaves and rakes, fabricated of same metal as metal wall panels.

2. Backing Plates: Provide metal backing plates at panel end splices, fabricated from material recommended by manufacturer.

3. Closure Strips: Closed-cell, expanded, cellular, rubber or crosslinked, polyolefin-foam or closed-cell laminated polyethylene; minimum 1-inch- (25-mm-) thick, flexible closure strips; cut or premolded to match metal wall panel profile.