This document is Appendix C - Specifications from solicitation A27-0598, detailing the technical requirements for two pieces of equipment.

The induction heater must operate on three-phase 208-240V AC power at 50/60 Hz with a maximum input current of 52A and maximum input power of 15 KW. The unit shall produce output frequency of 30-80 kHz with heating current capability of 5-50A. Timer control must be selectable between automatic and manual modes. The inverter box dimensions shall not exceed 43 cm (length) x 26 cm (width) x 37 cm (height). The equipment must be NRTL certified and include a water cooling option. The recirculating water chiller for the induction heater shall operate on 120V single-phase AC power (with capability to use 208-240V single-phase AC as an alternative) and provide 5 kW cooling capacity (17,500 BTU/hour) with temperature control range of 5-30°C and accuracy of ±0.3°C. The chiller shall feature a stainless steel heat exchanger, 58 liter/minute water flow rate, 28-meter head pressure (40 psi), and a 15-liter stainless steel water tank. The outlet connection must be compatible with the induction heater water inlet, and connection piping shall be polyurethane tubing with thickness greater than or equal to 2 mm and inner diameter greater than or equal to 8 mm. The chiller must also be NRTL certified.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. Induction heater

• Working voltage: 3 Phases, 208-240V AC, 50/60 Hz

• Max. input current: 52 A

• Output frequency: 30-80 kHz

• Heating current: 5-50A

• Max. input power: 15 KW

• Timer control: automatic timer control or manual control selectable

• Inverter box dimension no more than: 43 cm(L) x 26 cm(W) x 37 cm(H)

• NRTL certified

• Water cooling option (specification is listed below)

2. Recirculating Water Chiller for Induction heater

• Power supply: prefer 120 V single phase AC, but can use 208 -240V, single-phase AC.

• Cooling capacity: 5 kW (17500Btu/hour)

• Temperature control: 5~30 °C

• Temperature accuracy: ± 0.3 °C

• Heating exchanger: Stainless steel

• Water flow rate: 58 Liter / minute

• Head Pressure: 28 meters (or 40psi)

• Water tank: 15 Liters, stainless steel

• Outlet: compatible with the induction heater water inlet connection

• Connection pipe: polyurethane tube (thickness>=2 mm, ID>= 8 mm)

• NRTL certified

A27-0598 Appendix C - Specifications

File details come from the government source that posted it. Updated .