Appendix C - Specifications.pdf
PDF 47 KB Posted
- Attached to
- RFP-A27-0590 Vector Network Analyzer
- Solicitation number
- A27-0590
- Issued by
-
Department of Energy Ames Laboratory
About this file
This document is a technical specifications appendix for a Vector Network Analyzer procurement requirement.
The requirement specifies a two-port Vector Network Analyzer (VNA) as a standalone bench unit with a 12.1-inch TFT color LCD touch screen display and integrated mechanical button controls. The VNA must feature 3.5 mm female RF connectors with 2-port configuration and Direct Receiver Access (DRA) breakout jumpers for advanced RF measurements. Key performance specifications include frequency range from 100 kHz to at least 26.5 GHz, dynamic range of 135 dB or better, frequency resolution of 1 Hz or better, and IF bandwidth adjustable from 1 Hz to 10 MHz. Output power must range from -55 dBm to +10 dBm with 0.05 dB resolution and ±0.5 dB level linearity. Trace noise requirements are 0.005 dB rms and 0.012° rms or better. The analyzer must support S-parameter measurements (S11, S21, S12, S22), reflection and transmission measurements, and time-domain analysis with SCPI access to receiver ratios. Calibration capabilities must include response, enhanced response, full two-port, and TRL calibration options. The instrument must support linear, logarithmic, power, and time-domain sweep modes with at least 100,000 measurement points per sweep. Connectivity requires LAN and USB interfaces with remote control via SCPI, Labview, or IVI based on USB-TMC, VXI-11, Socket, Telnet, or WebServer protocols. Video output to external monitors (HDMI, DVI-D, or DisplayPort) is required. The VNA must be supplied with a calibration certificate, carry NRTL certification, and include a 3-year warranty. Equivalent instruments meeting or exceeding these minimum performance requirements are acceptable. The preferred delivery timeframe is within 8 weeks of purchase order receipt, with a maximum acceptable lead time of 12 weeks after receipt of order.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Vector Network Analyzer
Technical Specifications:
• Two-port Vector Network Analyzer (VNA)
• Standalone bench unit with integrated display and mechanical button controls, 12.1 inch TFT color LCD with touch screen controls.
• 2-port configuration with Direct Receiver Access (DRA) breakout jumpers for both ports, or equivalent functionality, for advanced RF measurements.
• 3.5 mm female RF connectors.
• Frequency range: 100 kHz to at least 26.5 GHz.
• Dynamic range: 135 dB or better.
• Frequency resolution: 1 Hz or better.
• IF bandwidth: Adjustable from 1 Hz to 10 MHz.
• Output power range: -55 dBm to +10 dBm with 0.05 dB resolution; level linearity ±0.5 dB
• Trace noise: 0.005 dB rms, 0.012° rms or better
• Measurement capabilities: S-parameter measurements (S11, S21, S12, S22), reflection and transmission measurements, and time-domain analysis. SCPI access to receiver ratios.
• Calibration capabilities:
Response, enhanced response, full two-port calibration, and TRL calibration.
• Sweep capability: Linear, logarithmic, power, and time-domain measurements.
• Measurement points: At least 100,000 points per sweep.
• Connectivity: LAN and USB interfaces, with support for remote instrument control through
SCPI or equivalent commands.
• Remote control: SCPI / Labview / IVI based on USB-TMC / VXI-11 / Socket / Telnet /
WebServer.
• Video output: to external monitor, HDMI / DVI-D / DP
• Supplied with calibration certificate.
• 3-year warranty.
• NRTL Certified Equivalent instruments meeting or exceeding these minimum performance requirements would be acceptable.
Maximum Acceptable Lead Time:
Our preferred delivery timeframe is within 8 weeks of receipt of the purchase order.
However, we can accommodate a maximum lead time of 12 weeks after receipt of the purchase order (ARO).