This document is a Statement of Objectives (SOO) for a Small Business Innovation Research (SBIR) contract opportunity titled "Dynamic Synthetic Tissues for Medical Simulation and Training" (A244-052). The project aims to develop material-based solutions that can demonstrate prolonged casualty care, nursing care, and trauma scenarios while dynamically changing patient state based on care provided. The solicitation falls under the Bio Medical and Human Systems technology areas with modernization priorities in Advanced Materials and Biotechnology. No CMMC level requirement or technical point of contact is identified.
The project requires synthetic tissue materials capable of five dynamic response capabilities: color and texture change to demonstrate symptoms such as bruising and infection; controlled swelling and edema without mechanical actuators; liquid secretion simulating blood and sweat; olfactory responses representative of wound conditions; and temperature control emulating medical complications like fever and frostbite. Phase I requires demonstration of a functional prototype incorporating at least two of the five capabilities with minimum dimensions of one inch by one inch, plus an outline of projected wound simulations. Phase II, budgeted at $1.1M over two years, requires integration of at least three capabilities into a complete moulage material with surrounding tissues, validation study comparing the prototype against current teaching methods, and capability for accelerated wound progression display. Phase III emphasizes transition to combat medic schoolhouses, advanced individual training locations, nursing providers, and surgical training facilities, with expansion of wound scenarios based on Phase II feedback. The target transition audience includes battalion aid stations and medical facilities operating at Role 2 or Role 3 levels.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Army_244_R19.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A244-052: Dynamic Synthetic Tissues for Medical Simulation and Training
PROJECTED CMMC LEVEL REQUIREMENT:
N/A
TECHNOLOGY AREAS:
Bio Medical | Human Systems
MODERNIZATION PRIORITIES:
Advanced Materials | Biotechnology
KEYWORDS:
Dynamic Wounds, Moulage, Medical, material-based swelling, nursing care, medical simulation, wound progression, synthetic biology
ADDITIONAL INFORMATION
N/A
OBJECTIVE:
Develop a material-based solution which can demonstrate prolonged casualty care (PCC), nursing care, and trauma scenarios while dynamically changing the patient state based on the care being provided.
DESCRIPTION:
Human patient simulators leverage unreliable mechanical air bladders, anatomically inaccurate synthetic tissues (Hannay et. all, 2022; Lee et. all, 2021; Norfleet et. all, 2015), and often do not accurately show a patient progression or regression during treatment. To increase training immersion, realism, and soldier buy-in, synthetic tissue materials must increase in fidelity and be capable of emulating real medical complications. These signs and symptoms should change in appearance over time while providing learners with the correct sensory cues to indicate a need for treatment. This project targets five material response areas of interest based on common medical symptoms. The synthetic tissue materials should demonstrate treatment proficiency feedback, i.e. the trainee performed the intervention correctly and the tissue shows improvement, or the trainee performed incorrectly, and the patient state worsens. Having synthetic tissue materials that demonstrate the cues required for intervention, look and behave realistically, respond appropriately to treatment, and dynamically change over time will improve training immersion and soldier buy-in while also enabling new PCC training scenarios.
The five targeted material response areas are:
Color change and texture change Ability of the material to change color to include symptoms or injuries including bruising, infection, and blisters
Inoculation – negative, positive, or no reaction○
Swelling/edema Controlled edema effect that does not require mechanical actuators or air bladders that detract from trainee immersion
The swelling of the tissue should be identifiable by the trainee and demonstrate the need for a medical intervention.
Application examples include demonstrating internal pressure from compartment syndrome that requires a pressure release through a fasciotomy.
Liquid secretion Ability to secrete appropriate liquids important to, or that provide realism, for the medical procedure being performed
Examples: blood, sweat, etc.○
The ability to produce smell based on the current state of the wound, simulation, or procedure being trained
Material should be capable of demonstrating olfactory responses representative of the wound and training scenario requirements
Example: burnt flesh smell for a burn scenario that requires an escharotomy○
Temperature control and temperature changes respective to medical conditions Emulate various levels of medical complications through the use of temperature control○
Examples: Fever, overheating, frostbite○
PHASE I:
Begin feasibility of topic of the synthetic materials capable of dynamic change over time. At the culmination of Phase I, the proposer will demonstrate the functional prototype with the following requirements:
Integration of as many of the five capabilities mentioned in the objectives section as possible (smell, temperature, swelling, liquid secretion, and color change) is advisable.
The minimum requirement for phase 1 is incorporation of at least two of the objective capabilities listed above.
Minimum 1 inch by 1 inch size requirement with a plan for appropriate size scale-up in Phase II.• Outline of projected wound simulations that these materials can replicate in the following phases.•
PHASE II:
Briefly describe expectations and minimum required deliverable, culminating in a well-defined prototype (a technology, product, or service) meeting the requirements of the topic and can be made commercially viable. (2 Yrs, $1.1M effort)
Phase II will build upon the initial findings and prototype from Phase I. This iteration will provide at least one additional capability from the previous material. This phase will also consist of a validation study on the effectiveness of the prototype as a training tool. A comparative analysis of the prototype against the current method of teaching is required.
Minimum integration of three capabilities in one moulage material (smell, temperature, swelling, liquid secretion, and color change).
The Phase 2 prototype should include tissues surrounding the wounded area.• Ideally, capable of demonstrating all five of the objectives over multiple moulage prototypes and overlapping integration as determined optimal for training.
Deliverables:
Dynamic materials capable of at least 3 of the identified requirements that are integrated into a wound or set of wounds that are representative of PCC, nursing care, or surgical care.
Complete set of wound materials and surrounding tissues that can simulate anatomical wound healing over time.
Capable of being sped up to “faster than real time” to allow trainees to experience the wound progression or degradation over PCC and nursing care timelines.
Training evaluation study or usability study of the prototype system.•
PHASE III DUAL USE APPLICATIONS:
The target transition audience for the end-state will include the combat medic schoolhouses and advanced individual training locations (Camp Bullis), civilian and military nursing providers, and even some lower level surgical training providers. The expected training experience will likely be that of a battalion aid station, Role 2, or even Role 3 depending on the performers wound selection. As part of the transition and commercialization process, Phase III should include building out relevant additional wounds and surrounding tissues based on the feedback and results found in Phase II
REFERENCES:
Norfleet, J., Mazzeo, M., Palata, K., Tenorio, L. M., Barocas, V., & Sweet, R. (2016). Thoracostomy Simulations: A comparison of the mechanical properties of human pleura vs synthetic training pleura.
MODSIM World, 19
1.
Hannay, V., Rahul, F. N. U., Josyula, K., Kruger, U., Gallagher, S., Lee, S., ... & De, S. (2022). Synthetic tissues lack the fidelity for the use in burn care simulators. Scientific Reports, 12(1), 21398.
2.
Lee, S., Rahul, Hannay, V., Gallagher, S., Lee, H., Imtiaz, A., ... & De, S. (2021). Evaluate the fidelity of synthetic tissues used in escharotomy simulators. In Mechanics of Biological Systems and Materials & Micro-and Nanomechanics & Research Applications: Proceedings of the 2020 Annual Conference on Experimental and Applied Mechanics (pp. 77-80). Springer International Publishing.
3.
Norfleet, J., Fenoglietto, F. L., & Mazzeo, M. (2015). Simulated Human Tissue Performance. In MODSIM World Meeting 2015.
4.
TECHNICAL POINT OF CONTACT (TPOC):
None