The provided document is a technical reference for a 2.5" corrugated commercial/residential roofing panel system. Key details include:

The roofing panels have 211/3" coverage, a minimum 3:12 roof slope, and are exposed fastened. Finishes include MS Colorfast45, Acrylic-Coated Galvalume, and Bare Galvanized. The panels are available in 30, 29, 26, 24, and 22 gauge thicknesses, with corrosion protection ratings of AZ55, AZ50, G60, G90 or G100. The panels are UL rated for impact, fire resistance, and Texas Windstorm. The document provides technical specifications, section properties, and allowable uniform load details for the panel system.

The related federal contract opportunity is for the National Park Service in the Yukon-Charley River National Preserve to procure galvanized roofing materials. The solicitation is set-aside for small businesses, under NAICS code 332322 with a 500-employee size standard. Quotes are due via email, and the resultant award will be a firm-fixed price purchase order.

View the file

Other files for this federal contract opportunity

Other files attached to GALVANIZED ROOFING MATERIALS, newest first.
File Type Posted
Sol_140P9724Q0037.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CCondensed TTe c h n i c a l RR e f e r e n c e

OPEN FRAMING OR

SOLID SUBSTRATE

COMMERCIAL

RESIDENTIAL

PANEL

211/3"

COVERAGE

MINIMUM

SLOPE

3:12

EXPOSED

FASTENED

Finishes: MS Colorfast45®, Acrylic-Coated Galvalume® and Bare Galvanized Corrosion Protection: AZ55 per ASTM A 792 for unpainted Galvalume®

AZ50 per ASTM A 792 for painted Galvalume®

G60, G90 or G100 per ASTM A 653 for Galvanized Gauges: 30 ga, 29 ga and 26 ga standard; 24 ga and 22 ga optional 211/3" panel coverage, 1/2" rib height Panel Length: Minimum: 3'-6"; Maximum: 30' recommended Exposed fastened, low profile roof system Corrugated ribs on 22/3" centers Minimum roof slope: 3:12

PANEL OVERVIEW

2.5" CORRUGATED

UL 2218 Impact Resistance - Class 4 UL 790 Fire Resistance Rating - Class A, per building code UL 263 Fire Resistance Rating - per assembly Texas Windstorm - Evaluation RC-159 2017 FBC Approvals - FL14645.1 ICC Evaluation Report - ESR-2385

TESTING AND APPROVALS

11/3" 22/3"

211/3" Roof Coverage

12" 1/2"

ROOF PANEL

C dpapke Highlight dpapke Highlight dpapke Highlight

CCondensed TTe c h n i c a l RR e f e r e n c e

M

S M

C /3

-2

Anchorage, AK 866.640.7663 Bay City, MI 888.777.7640 Deer Lake, PA 800.544.2577 Denver, CO 800.289.7663

Detroit Lakes, MN 888.594.1394 Fontana, CA 800.782.7953 Fort Smith, AR 877.452.3915 Independence, MO 800.747.0012

Jacksonville, FL 800.394.4419 Jefferson, OH 800.321.5833 Mocksville, NC 800.228.6119 Nashville, TN 800.251.8508 Rock Island, IL 800.747.1206 Rogers, MN 800.328.9316

Seattle, WA 800.431.3470 Sellersburg, IN 800.999.7777 Sioux Falls, SD 888.299.0024 Spokane, WA 800.572.6565 Temple, TX 800.543.4415 Woodland, CA 800.759.6019 metalsales.us.com

Overdriven fasteners will cause panel distortions.

Fasteners should extend 1/2" or more past the inside face of the support material.

Thick panels (ex. 18 ga) or supports (ex. 1/2" steel) may require predrilling of holes for screws.

Panel Fasteners:

Attaching to Wood:

#10-14 Wood Screw #10-14 XL Wood Screw

Attaching to Steel:

#12-14 Self Drilling Screw #12-14 XL Self Drilling Screw

Side Lap Fastener:

1/4"-14 x 7/8" Stitch Screw 1/4"-14 x 7/8" XL Stitch Screw

Trim Fastener:

1/4"-14 x 7/8" Stitch Screw 1/4"-14 x 7/8" XL Stitch Screw

FASTENER INFORMATION

2.5" CORRUGATED

SECTION PROPERTIES ALLOWABLE UNIFORM LOADS, psf For various fastener spacings

Ga Width in

Yield ksi

Weight psf

Top In Compression Bottom In Compression Inward Load Outward Load Ixx in4/ft

Sxx in3/ft

Ixx in4/ft

Sxx in3/ft 2' 2.5' 3' 3.5' 4' 4.5' 2' 2.5' 3' 3.5' 4' 4.5'

30 21.33 80 0.66 0.0051 0.0202 0.0051 0.0185 107 55 32 20 14 9 107 55 32 20 14 9 29 21.33 80 0.70 0.0056 0.0215 0.0056 0.0208 118 60 35 22 15 10 118 60 35 22 15 10 26 21.33 50 0.90 0.0073 0.0275 0.0073 0.0274 153 78 45 29 19 13 153 78 45 29 19 13 24 21.33 50 1.17 0.0096 0.0354 0.0096 0.0354 200 102 59 37 25 18 200 102 59 37 25 18 22 21.33 50 1.53 0.0124 0.0457 0.0124 0.0457 259 133 77 48 32 23 259 133 77 48 32 23

ATTACHMENT DETAILS

FASTENING PATTERN

Panel Fastener

Field of Panel

Ends of Panel

Side Lap Fastener

Panel Fastener

Side Lap Fastener

Panel Fastener Side Lap Fastener

1. Theoretical section properties have been calculated per AISI 2016 'North American Specification for the Design of Cold-Formed Steel Structural Members'.

Ixx and Sxx are effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2016 specifications considering bending, shear, combined bending and shear and deflection. Allowable load considers the 3 or more equal spans condition. Allowable load does not address web crippling, fasteners, support material or load testing. Panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase for wind.