This purchase description outlines requirements for a UH-60 Heater Mat Tester to be acquired by the Missouri Army National Guard Aviation Classification Repair Activity Depot. The tester would assess heating mats on UH-60 Blackhawk tail rotor blades and include a high voltage analyzer test system, desktop computer, monitor, printer, power control unit, test software, and modular test analyzer with switching modules and cards capable of voltage, current, and capacitance measurement up to 1500V and 2A. The related federal contract opportunity is a solicitation from the Department of the Army National Guard for this UH-60 Heater Mat Tester with responses due under solicitation number W912NS23Q8511.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W912NS23Q8511
Missouri National Guard UH-60 Heater Mat Tester AVCRAD
Objective of the Acquisition
The Missouri Army National Guard’s Aviation Classification Repair Activity Depot (AVCRAD) is seeking to purchase a High Voltage Analyzer (HVA) test system to assess heating mats on UH- 60 Blackhawk (Victor and Lima models) tail rotor blades.
CLIN 0001) UH-60 Heater Mat Tester:
a. High Voltage Analyzer (HVA) test system to assess heating mats on UH-60 tail rotor blades containing the following components:
i. One (1) switching module and four (4) - HVA switching cards (50 points each) totaling 200 points.
ii. Minimum Desktop Computer Assembly, i5 Intel® Processor, 8GB Memory, 256GB Storage Drive, SSD Drive, two (2) LAN Ports, one (1) USB port, keyboard, a trusted Platform Module TPM 2.0, mouse, MS Windows® 11 PRO 64bit OS.
iii. Flat screen monitor.
iv. Laser printer with USB cable.
v. Power Control/Surge Suppressor
vi. Tested Software & Hardware integration
b. Modular Test Analyzer (MTA) with MTA controller and HVA port capable of
1500V, 2 Amp, 4-wire, DC HIPOT and AC volt measurement, and capacitance measurement shall include the following:
i. Netlink Interface Cable, 10 feet long
ii. Standard Measurement Unit (SMU) comparator, programmable, up to
1500 VDC IR & DC HIPOT, and up to 2A continuity and resistance testing.
iii. 1500 VAC Real Current AC Detector.
iv. Segment driver to drive up to 15,000 test points.
v. One (1) CD-ROM with Standard Operation and Maintenance Manuals.
vi. One (1) Set Standard Operating Software and license agreement.
vii. Standard Input Power 115 Volt, Single-Phase, 50/60 Hz.
c. One (1) HVA switching module with dual D interface connectors (max. 700 points per module)/dual-D panel including seven (7) connectors.
d. Four (4) HVA switching card (1500 VAC) 50 points (operates in HVA modules only)
e. One (1) Daisy chain interconnect cable, three (3) feet length
f. One (1) Portable Single Bay Cabinet (3119/51) with A/C Input Assembly
CLIN 0002) Modification to UH-60 Heater Mat Tester:
a. Add one (1) switching module and move two switching cards from the switch module listed above to this module (includes 3 ft. Daisy Chain cable).
File details come from the government source that posted it. Updated .