This document outlines requirements for a UH-60 Heater Mat Tester procurement. The Missouri Army National Guard's Aviation Classification Repair Activity Depot seeks to purchase a High Voltage Analyzer test system to assess heating mats on UH-60 Blackhawk tail rotor blades. The system shall include a switching module and cards, desktop computer, monitor, printer, surge protector, software, and modular test analyzer with controller, interface cable, comparator, detector, driver and manuals. Additionally, the procurement seeks a switching module with connectors, four switching cards, interconnect cable and cabinet. Modification requirements include adding a switching module and moving two cards to it along with a daisy chain cable.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W912NS23Q8511

Missouri National Guard UH-60 Heater Mat Tester AVCRAD

Objective of the Acquisition

The Missouri Army National Guard’s Aviation Classification Repair Activity Depot (AVCRAD) is seeking to purchase a High Voltage Analyzer (HVA) test system to assess heating mats on UH-60 Blackhawk tail rotor blades.

CLIN 0001) UH-60 Heater Mat Tester:

a. High Voltage Analyzer (HVA) test system to assess heating mats on UH-60 tail rotor blades containing the following components:

i. One (1) switching module and four (4) - HVA switching cards (50 points each) totaling 200 points.

ii. Minimum Desktop Computer Assembly, i5 Intel® Processor, 8GB Memory, 256GB Storage Drive, SSD Drive, two (2) LAN Ports, one (1) USB port, keyboard, a trusted Platform Module TPM 2.0, mouse, MS Windows® 11 PRO 64bit OS.

iii. Flat screen monitor.

iv. Laser printer with USB cable.

v. Power Control/Surge Suppressor

vi. Tested Software & Hardware integration

b. Modular Test Analyzer (MTA) with MTA controller and HVA port capable of 1500V, 2 Amp, 4-wire, DC HIPOT and AC volt measurement, and capacitance measurement shall include the following:

i. Netlink Interface Cable, 10 feet long

ii. Standard Measurement Unit (SMU) comparator, programmable, up to 1500 VDC IR & DC HIPOT, and up to 2A continuity and resistance testing.

iii. 1500 VAC Real Current AC Detector.

iv. Segment driver to drive up to 15,000 test points.

v. One (1) CD-ROM with Standard Operation and Maintenance Manuals.

vi. One (1) Set Standard Operating Software and license agreement.

vii. Standard Input Power 115 Volt, Single-Phase, 50/60 Hz.

c. One (1) HVA switching module with dual D interface connectors (max. 700 points per module)//dual-D panel including seven (7) connectors.

d. Four (4) HVA switching card (1500 VAC) 50 points (operates in HVA modules only)

e. One (1) Daisy chain interconnect cable, three (3) feet length

f. One (1) Portable Single Bay Cabinet (3119/51) with A/C Input Assembly CLIN 0002) Modification to UH-60 Heater Mat Tester:

a. Add one (1) switching module and move two switching cards from the switch module listed above to this module (includes 3 ft. Daisy Chain cable).