View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A19-165: Measurement of Water Volume for Real-Time Hydration Status and IoT Logistical Readiness

PROJECTED CMMC LEVEL REQUIREMENT:

N/A

TECHNOLOGY AREAS:

Human Systems

MODERNIZATION PRIORITIES:

KEYWORDS:

Hydration, Water Level, Water Bladder, Internet of Things, IoT, Body Area Networks, BAN, Logistics, LACE reporting, Lethality, Readiness, Sensor, Sensors, Body Worn Sensors, Individual equipment, Wireless, Inter-Soldier Wireless, ISW, IVAS, Nett WArrior, ATAK

ADDITIONAL INFORMATION

OBJECTIVE:

Design and build a sensor that measures the volume of water in a Soldier's water bladder and/or canteen. This digital information can be used to predict the Soldier's hydration level, maintaining their readiness, cognition, and lethality.

DESCRIPTION:

Despite current Army practices, Soldiers continue to suffer heat injuries in training and on the battlefield.

Maintaining soldier readiness is key to maintaining Solider lethality. To solve this, the Army is separately pursuing a system to monitor and predict Soldier hydration via a system of body worn sensors and physiologically validated algorithms [1] [2] [3]. A crucial part of this separate system is the capability to measure the volume of water a Soldier is consuming throughout the day. The few technologies that exist are either not well suited for field use, not accurate enough, or are too immature for integration. This system, when complete will ensure the effectiveness and lethality of Army units by keeping Soldiers in the fight. The desired technology should have two capabilities: 1) Measure and record the amount of water the user drinks on a threshold (T): hourly or objective (O):

minute basis throughout the day in outdoor free-living and field environments. The technology should be flexible enough to accommodate several form factors, as Soldiers drink from several water containers, including:

canteens, backpack water bladders, commercial Nalgene-type bottles and other sources such as disposable water bottles. 2) Measure the volume of water the soldier is carrying in their water containers at any given time. This data would be used in a separate system, for example, for logistical purposes to track and predict a unit’s water resupply needs using near-real time data. (Proposer is not responsible for any logistic software) Technologies with only one of these capabilities will be considered, although both capabilities are desired. Technologies that monitor the user rather than the equipment to obtain drinking behavior will also be considered. Other requirements include the following: The technology shall be: • Lightweight enough to integrate with the Soldier’s kit without notice • Accurate within +/- 10% of reference or better over a 2 liter range. • Digital and able to report data wirelessly over standard BLE protocols • Safe for use with potable water • Should be able to be used accurately and successfully in a free living environment e.g. sideways or upside down, over various terrain and non-freezing temperature ranges up to 120°F.

PHASE I:

Evaluate the efficacy of the proposed technological solution compared to other possible solutions and current technologies and prepare a tradeoff study. Demonstrate the feasibility and accuracy of the technology with a benchtop prototype. Identify technology and capability gaps to show how the technology can be developed into a TRL 6 prototype at the end of Phase II. Identify ways to integrate or retrofit the technology into a relevant water container. Demonstrate or describe in engineering terms how the technology would be able to withstand the complexities of free-living and field use. e.g. will the technology work if the container is turned upside down?

Phase I deliverables include: • Monthly reports • A final technical report describing o Development and testing of the technology o Technology gaps and recommendations for future work o Estimated cost in production • Demonstration of the state of the art of the technology

PHASE II:

The goal of Phase II is to develop and demonstrate a TRL6 technology. First, verify and validate the operation, accuracy, and robustness of all features and requirements in a lab environment. Evaluate the impact and cost of various levels of integration. Integrate the technology with one or more relevant water containers. Provide measurement data in standard BLE formats. Test the integrated system in a controlled environment and in free-living environments. Provide an estimate of production cost. Deliver 10 systems for Soldiers to test in a field environment. Include user guide, interface control document, and development guide so that the imbedded software can be configured and BLE messages can be received.

PHASE III DUAL USE APPLICATIONS:

Further refine the technologies features and capabilities. Present a design that is manufactureable at a price point that is competitive and reasonable for the intended market. COMMERCIALIZATION AND DUAL USE There are several applicable markets for this technology, especially since the advent and increased adoption of the Internet of Things (IoT). This water monitoring technology can be used in several DoD markets, especially any organization dealing with high risk of dehydration such as encapsulated CBRNE operations. Also: • First responders • The outdoor market • Leisure and health market • Physiological testing market in universities • The medial market for IV intake • Commercial applications dealing with liquid levels in manufacturing

REFERENCES:

Journal of Applied Physiology 112: 1300–1310, 2012. "Sweat rate prediction equations for outdoor exercise with transient solar radiation"; R. R. Gonzalez, S. N. Cheuvront,B.R. Ely, D. S. Moran,A. Hadid,T L.

Endrusick,M. N. Sawka

1.

“Army develops app to determine body's water needs”; Army.mil; Kelly Field, October 24, 2014;

https://www.army.mil/article/136391/army_develops_app_to_determine_bodys_water_needs

2.

Journal of Applied Physiology 107: 379–388, 2009; “Expanded prediction equations of human sweat loss and water needs”; R. R. Gonzalez, S. N. Cheuvront, S. J. Montain, D. A. Goodman, L. A. Blanchard,2 L. G.

Berglund, and M. N. Sawka

3.

TECHNICAL POINT OF CONTACT (TPOC):

None

File details come from the government source that posted it. Updated .