A16-121.pdf

PDF 45 KB Posted

Attached to
Active fan/blower noise reduction
Solicitation number
A16-121
Issued by

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A16-121: Active fan/blower noise reduction

PROJECTED CMMC LEVEL REQUIREMENT:

N/A

TECHNOLOGY AREAS:

Ground Sea

MODERNIZATION PRIORITIES:

KEYWORDS:

active noise control, fan, blower

ADDITIONAL INFORMATION

OBJECTIVE:

Develop an actively controlled system to reduce the noise emitted from cooling fan and/or blower noise by no less than 10 dB

DESCRIPTION:

As the noise generated from the engine and drivetrain of power generation systems gets treated to desired levels, the most significant noise source left to eliminate is the noise generated by air mover for the cooling system.

Current state of the art systems have been developed for computer fan noise that imbed magnets in the fan to be used to create the noise canceling sound wave. This solution is not practical for military applications because of the extreme environment that the solution will see in application and the extreme vibration of military applications. The solution desired in this topic shall be innovative in that it could be used over a wide temperature range (-40 F to 145 F) and be applicable to both conventional fan/radiator applications as well as in blowers used to feed air to fuel cell stacks.

PHASE I:

Should include a feasibility study to include how the solution would accommodate the temperature ranges and the fan/radiator as well as the blower applications. The control strategy shall be determined and evaluated showing conformance for the fore mentioned variables. A proof of control concept shall be demonstrated for technical merit. A system durability evaluation shall be included to prove the technical merit of the solution. The commercial merit shall be evaluated with an estimate for final cost

PHASE II:

The system shall be developed and demonstrated to show the ability to produce the desired results in at the extremes of the temperature range. The system shall also be demonstrated on the fan/radiator and the blower applications. The durability of the system shall be demonstrated through an accelerated life cycle vibration test for a potential application. The final solution shall be evaluated to determine the commercial viability in phase II also.

PHASE III DUAL USE APPLICATIONS:

Applications for this system shall be for a military Auxiliary Power Units (APU) application that uses a fan/radiator system and for a blower in a fuel cell application. The potential commercial application includes fuel cell vehicles and commercial bus applications where the cooling fan noise is significant for pedestrians.

REFERENCES:

http://www.geek.com/chips/noctua-adds-active-noise-cancellation-to-a-cpu-fan-1495099/1.

https://www.irjet.net/archives/V3/i2/IRJET-V3I288.pdf2.

http://www.google.com/patents/US54486453.

http://gizmodo.com/first-active-noise-canceling-computer-fan-will-finally-5134466484.

TECHNICAL POINT OF CONTACT (TPOC):

None

File details come from the government source that posted it. Updated .