A16-073: Abrams Engine Stall Detection Sensor

PROJECTED CMMC LEVEL REQUIREMENT:

N/A

TECHNOLOGY AREAS:

Ground Sea

MODERNIZATION PRIORITIES:

KEYWORDS:

Abrams, AGT-1500, Turbine, Compressor, Stall

ADDITIONAL INFORMATION

OBJECTIVE:

Develop a solution capable of detecting the onset of compressor stall or stall precursors in gas turbine engines for the purpose of enabling the suppression of rotating stall prior to a surge event.

DESCRIPTION:

The Abrams engine (AGT-1500) is a 1500 hp turbine engine. It is currently suffering from a stalling issue in which the compressor stalls, creating a surge event that causes significant damage to the fourth stage of the low pressure compressor. This damage nearly always results in powerpack removal and a return to the depot to repair. The cost associated with the compressor repair can be up to $200k. While there are currently no other Army ground vehicles that use a turbine engine, there are applications to various aircraft and watercraft. In-depth explanation: There are two classes of compressor stall. The first, rotating stall, is a major limitation of modern turbine engines. In this case a small proportion of compressor blades experience flow separation, creating a region of stalled air which circulates around the engine at roughly half the speed of the rotor’s revolution. Key impacts of rotating stall are loss of efficiency, reduction in engine output power, and excess mechanical loading on the compressor blades. Additionally, rotating stall can progress to initiate axi-symmetric stall ("surge”). In an axi-symmetric stall, the entire compressor stage loses the ability to operate, resulting in a local reversal of the air flow. This in turn can cause the stalling of the preceding stage, and allow the phenomenon to propagate forwards through the engine, resulting in compressor surge. In this case the engine completely loses compression, resulting in a reversal of flow through the engine. This, in turn, can cause engine wear, extreme vibration, and even total destruction of the engine. Often the conditions which create the surge remain in place for a period of several seconds, resulting in a repeated surging of the engine. The surge phenomena is common to all turbine engines most specifically those using axial flow turbomachinery and are caused by numerous sources. There are numerous causes of compressor stall and surge, ranging from attempting to increase the engine speed too rapidly, to ingestion of a foreign object, erosion of engine parts, or extreme maneuvering. Surge can also be caused by an engine ingesting hot gases. Solution: What is needed is viable system for measuring the early stages of rotating stall in real-time on an operational turbine engine. We are seeking a technical solution that can detect a surge event in order to take action through the control system to avoid structural damage to compressor blades. The challenge is to monitor the compressor operation without impact to performance in a timely fashion that can be incorporated into the harsh Abrams engine environment for temperature, dust, shock and vibration.

PHASE I:

Provide analysis indicating optimal method for identifying/predicting compressor surge. Provide analysis showing maximum amount of time allowable to “move away” from the stall point before catastrophic damage occurs.

Develop solution that will identify a compressor surge on the low pressure compressor operating at 25,000 to 33,000 rpm and move the compressor away from the failure point. Deliverables include the technical analysis data and final report. The government will provide design details of the AGT-1500 as needed.

PHASE II:

Develop prototype system that includes new data analysis and analytical capabilities at engine relevant conditions. Fabricate 2 surge detection systems suitable for laboratory testing. Conduct laboratory testing on engine throughout engine operating range and during induced surge / stall event. Demonstrate identification and correction of surge / stall event with laboratory level equipment. Identify design changes suitable for vehicle level testing including integration into engine control system. Coordinate results and recommendations with engine OEM. Deliverables include the prototype hardware and software, technical data, test results, and final project report.

PHASE III DUAL USE APPLICATIONS:

Following successful completion of Phase II and endorsement of PM Abrams, develop a suitable solution for installation into the Abrams. . Design, fabricate, acquire, and integrate hardware to be installed and tested on the vehicle. Demonstrate operational suitability, reliability, and safety of the prototype to adequately demonstrate a TRL 7 for acquisition. The contractor will be required to coordinate results and recommendations with the engine OEM. Besides applications to the Abrams AGT-1500 Turbine, this technology could be applied to other Turbine applications, such as commercial jet aircraft, larger seafaring vessels, and some trains.

REFERENCES:

TRADOC Regulation 71-20. Concept Development, Capabilities Determination, and Capabilities Integrations, 28 June 2013 (http://www.tradoc.army.mil/tpubs/regs/tr71-20.pdf)

1.

Cousins, W. T. (1997). The Dynamics of Stall and Surge Behavior in Axial Centrifugal Compressors. Doctoral Dissertation. Virginia Tech. (http://scholar.lib.vt.edu/theses/available/etd-11298- 35210/unrestricted/etd.pdf)

2.

Christian Van Schalkwyk, M. M. (n.d.). Active Control of Rotating Stall Demonstrated for a Multistage Compressor With Inlet Distortion. (http://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/20050196613.pdf)

3.

TECHNICAL POINT OF CONTACT (TPOC):

None

File details come from the government source that posted it. Updated .