A06_-_Submittals.pdf
PDF 34 KB Posted
- Attached to
- CO-ROCKY MTN ARSNL NWR-REHAB SECTION 12
- Solicitation number
- 140FC123R0019
About this file
This document contains a project submittal list for the installation of a new pump/motor, pipe conveyance system, and culvert upgrade at the Rocky Mountain Arsenal in Colorado under solicitation number 140FC123R0019 issued by the Department of the Interior Fish and Wildlife Service.
The submittal list requires the contractor to provide documentation for materials, tests, certifications, samples, and manuals for items related to steel reinforcement, joint filler, concrete mix, well house fabrication, pipe materials, gate valves, warning tape, water meters, check valves, subbase materials, base materials, engineered fill, riprap, riprap bedding, well contractor licensing, pump warranty, operation and maintenance plans, pump test results, water quality test results, drop pipe, redevelopment process, well pumps, well motors, well electrical components, well heads, culvert pipe, pipe coating, directional drill logs, as-built drawings, geotextile fabric, floor drain pipe, and floor drain grating. The list specifies the required action for each submittal as approved, approved with notes, no action taken with comments required, or disapproved with resubmission required.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET 1 OF 2
PROJECT NAME: SECTION 12 WELL ENGR. PROJECT NO.: 23-008
LOCATION: ROCKY MOUNTAIN ARSENAL CONTRACT NO.:
CONTRACTOR:
Spec.
Section
Number
Spec.
Paragraph
No.
Description of item and submittal type (i.e. shop drawings, manufacture cut sheets, tests required, certifications, samples, operating and maintenance manuals, etc.)
Contractor's
Submittal
Number
Date
Submitted
Action
Taken
Date
Resubmitted
Action
Taken Comments
033000 2.2 Steel reinforcement
033000 2.7 Joint filler
033000 2.8 Concrete mix
133423 2 Fabricated well house or all materials for custom build
221116 2.3 Pipe material
221116 2.4 Gate valve
221116 2.5 Warning tape
221116 2.6 Water meter
221116 2.7 Check valve
313215 2.1.B Subbase material
313215 2.1.C Base material
313215 2.1.D Engineered fill
313215 2.2 Riprap
313215 2.3 Riprap bedding
332100 1.4 Well contractor license
332100 1.5 Pump warranty
332100 1.5 Operation and maintenance plan
332100 1.7 Pump test results
332100 1.8 Water quality test results
332100 1.10.B Drop pipe
332100 1.10.C Redevelop process
PROJECT SUBMITTAL LIST
A - Approved as Submitted.
B - Approved, Except as Noted. No Resubmission Required.
C - Approved, Except as Noted. Resubmission Required.
D - No Action Taken. See Comments. Resubmission Required.
E - disapproved. See Comments. Resubmission Required.
SHEET 2 OF 2
PROJECT NAME: SECTION 12 WELL ENGR. PROJECT NO.: 23-008
LOCATION: ROCKY MOUNTAIN ARSENAL CONTRACT NO.:
CONTRACTOR:
Spec.
Section
Number
Spec.
Paragraph
No.
Description of item and submittal type (i.e. shop drawings, manufacture cut sheets, tests required, certifications, samples, operating and maintenance manuals, etc.)
Contractor's
Submittal
Number
Date
Submitted
Action
Taken
Date
Resubmitted
Action
Taken Comments
PROJECT SUBMITTAL LIST
332100 2.3 Well pump
332100 2.4 Well motor
332100 2.5 Well electrical components
332100 3.2 Well head
333100 2.1.A Culvert pipe
333100 2.1.B Pipe coating
333100 3.3 Directional drill log
333100 3.4 As-built
334102 2.1.A Culvert
Draw 3C 3 Geotextile fabric
Draw 3C 3 Floor drain pipe
Draw 3C 3 Floor drain grating
NOTE: The list may not included all required items.
A - Approved as Submitted.
B - Approved, Except as Noted. No Resubmission Required.
C - Approved, Except as Noted. Resubmission Required.
D - No Action Taken. See Comments. Resubmission Required.
E - disapproved. See Comments. Resubmission Required.