This document is a detailed specification for MCFO Steel Fence Materials, outlining specific requirements for fence components to be procured by the Department of the Interior Bureau of Land Management. The specification covers five primary items: Steel Brace Posts (long and short), Steel Brace Rails, Drill Stem Mechanical Gate Closer, Gate Loop, Heavy Duty Steel Fence Posts, Heavy Duty Barbed Wire, and Heavy Duty Barbless Wire. Each item has precise technical specifications, including material composition, dimensions, weight, coating requirements, and quality standards, with specific quantities noted for each component (e.g., 172 long steel brace posts, 4000 heavy duty steel fence posts). The materials must meet specific ASTM standards, with explicit requirements for zinc coating, breaking strength, and manufacturing processes, and failure to meet these specifications will result in material rejection during inspection.

View the file

Other files

File Type Posted
Sol_140L3625Q0069_Amd_0001.pdf PDF
Solicitation_Body_6_30_25_Amendment_0001_0001.pdf PDF
A06_Drawings.pdf PDF
Sol_140L3625Q0069.pdf PDF
Schedule_of_Items.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MCFO STEEL FENCE MATERIAL

MCFO STEEL FENCE MATERIAL

Item 1.

Item 2.

Item 3.

Item 4.

Steel Brace Post (Long) 2-7/8” by 9’ (Quantity 172)

Steel Brace Posts (Long): Shall be 2-7/8” outside diameter, (OD) by 0.217” minimum wall thickness, by 9’ in length, Oil Company Tubular Goods (OCTG) steel pipe. Pipe shall be used/recycled structural OCTG casing or drill pipe in sound structural condition, clean and radiation free (<12 µR/hr.), or new reject pipe, or unused surplus pipe. Surface rust is acceptable; however, any material that is excessively pitted, rusty, flaking, peeling, or corroded will be rejected. Pipe with splits, bends, or thin spots (hot spots) will not be accepted. Pipe shall be free from oil debris. All pipe that is concrete lined, lined with any synthetic material, has holes or perforations shall not be accepted. All drill stem threads and/or collars shall be removed.

Steel Brace Post (Short) 2-7/8” by 4’ (Quantity 286)

Steel Brace Posts (Short): Shall be 2-7/8” outside diameter (OD) by 0.217” minimum wall thickness, by 4’ in length, Oil Company Tubular Goods (OCTG) steel pipe. Pipe shall be used/recycled structural OCTG casing or drill pipe in sound structural condition, clean and radiation free (<12 µR/hr.), or new reject pipe, or unused surplus pipe. Surface rust is acceptable; however, any material that is excessively pitted, rusty, flaking, peeling, or corroded will be rejected. Pipe with splits, bends, or thin spots (hot spots) will not be accepted. Pipe shall be free from oil debris. All pipe that is concrete lined, lined with any synthetic material, has holes or perforations shall not be accepted. All drill stem threads and/or collars shall be removed.

Steel Brace Rail 2” by 7’ (Quantity 286)

Steel Brace Rail: Shall be a minimum of 7’in length not to exceed 8’ in length, singular piece of round tubular steel constructed with a minimum 1-7/8” outside diameter, by minimum 11-gauge wall thickness. Brace rail ends shall be pressed flat on both ends and be equipped with both a 90- and 45-degree angle capable of being mounted both horizontally as well as diagonally on all bracing structures. Brace banding shall be 2-7/8” heavy duty galvanized brace band, measuring 1” wide by minimum 1/8” wall thickness and supplied with 3/8” galvanized grade five (5) carriage bolts, 1-1/2” to 2” in length with grade five (5) galvanized flange nuts.

Drill Stem Mechanical Gate Closer (Quantity 31)

Gate Closer: A36 rolled round steel bar 3/16” to 5/16” diameter or adjustable minimum

3/16” diameter galvanized steel cable wire loop with a minimum Working Load Limit

(WLL) 840 lb. force and Minimum Breaking Load (MBL) 4200 lb. force, fastened to a cam lever device. The pipe cover shall be constructed of a minimum 11-gauge steel plating made to rest upon and exceed the diameter of the 2-7/8” steel brace post.

Certification: The Contractor shall furnish written certification from the manufacturer that the Contractor-furnished fence posts and wire conform to the requirements of this section.

Item 5.

The mechanical break over latch shall be attached to a minimum of 2-3/8” (OD) by 11-gauge minimum wall thickness tubular steel stem that slides securely into the 2-7/8”

(OD) steel brace post a minimum of 6”. The steel stem shall be radiation free (<12 µR/hr.). The closer must be capable of fitting over a maximum 4” diameter wood gate stay and securely holding the gate stay in place. Alternatives require prior approval by the Contracting Officer (CO) with submission of samples.

Gate Loop (Quantity 97)

Gate Loop: A minimum 3/16” diameter galvanized steel cable wire loop with a minimum Working Load Limit (WLL) 840 lb.-force and Minimum Breaking Load

(MBL) 4200 lb. force, attached to a 3” U-bolt muffler clamp assembly and shaped so a maximum 4” diameter gate stay will be securely held in place. The muffler clamp shall be secured to the steel brace post with 9/16” grade five (5) galvanized round U-bolt and galvanized flange nuts. A sleeve shall be welded to the muffler clamp, parallel to a leg of the U-bolt. Another sleeve shall be welded parallel to the other leg of the U-bolt, on the same face of the muffler clamp. The sleeve shall be large enough to allow free movement of the steel galvanized cable but small enough to keep terminated ends from passing through when the loop is under pressure. The galvanized steel cable shall be threaded through the sleeves to form a loop without a bind and the ends shall be crimped with a flattened 9/16” grade five (5) galvanized nut further secured by a weld. Alternatives require prior approval by the CO with submission of samples.

MCFO FENCE MATERIALS

MCFO FENCE MATERIALS

Item 6.

Item 7.

Heavy Duty Steel Fence Posts 5-1/2’ (Quantity4000)

Heavy Duty Steel Fence Posts 5-1/2’: (Chicago Steel or Approved Equal) Shall be a heavy duty grade 5-1/2’ steel posts painted green with white, silver, or lime green tops or painted gray with red, white, or silver tops, “T” bar type, with a swaged or riveted anchor plate which does not easily bend or twist when an obstruction is hit during the driving process. Other steel post painted colors can be allowed on a case by case basis with the approval of the Contracting Officer (CO). Posts shall be furnished with clip-type fasteners. Punched tabs for fastening wires are not acceptable. Steel posts shall be manufactured from wrought, rail, or new billet steel, and shall weigh a minimum of 1.33 lb/ft exclusive of the anchor plate, which shall weigh a minimum of 0.67 lbs., with a minimum of 18 sq. inches in area. Posts shall meet all ASTM A702 requirements and must be tagged accordingly. Failure to meet any of these requirements shall result in the rejection of material at the time of inspection.

Heavy Duty Barbed Wire (Quantity 149)

Heavy Duty Barbed Wire: (Redbrand or Approved Equal) Two 12-1/2 ga.

galvanized wires twisted together with 2-point barbs of 14 ga. wire spaced 4”- 6” apart. Wire and barbs shall be zinc-coated steel, with a zinc coating of at least 0.28 oz/ft2 of coated surface area and a minimum breaking strength of 950 lb-force. The barbed wire shall be a heavy duty wire conforming to ASTM A121 requirements.

Failure to meet any of these requirements shall result in the rejection of the material at the time of inspection.

Heavy Duty Barbless Wire (Quantity 49) Item 8.

Heavy Duty Barbless Wire: (Redbrand or Approved Equal) Two 12-1/2 ga.

galvanized wires twisted together. Wire shall be zinc-coated steel wire of at least

0.28 oz/ft2 of coated surface area and a minimum breaking strength of 950 lb-force.

The wire shall be heavy duty with a high tensile strength, low stretch, tight braiding per rod, conform to all ASTM A641 requirements and must be tagged accordingly.

Failure to meet any of these requirements shall result in the rejection of the material at the time of inspection.

A06 Specifications 3624P0018