This document outlines specifications for a Montana-Dakotas Field Office steel fence material contract scheduled for 2023. The contract requires the supply of steel brace posts measuring 2-7/8 inches in diameter by 9 feet in length, constructed of oil company tubular goods steel pipe in sound structural condition. Additional materials include steel line posts, tension wire, and galvanized barbed wire. All steel fence materials must meet specifications for dimensions, material composition and quality, and be free of radiation contamination.
The related federal contract opportunity is solicitation number 140L3624Q0025 from the Department of the Interior Bureau of Land Management Montana-Dakotas seeking proposals for an MCFO steel fence supply contract in 2024. The solicitation involves the procurement of steel fence materials to specification for BLM land management use. Offerors should follow submission instructions and anticipated award and performance dates outlined in the full solicitation document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140L3624Q0025_Amd_0001.pdf | ||
| A06_Revised_Specifications_0001.pdf | ||
| A06_Gate_Closer_Drawing.pdf | ||
| Sol_140L3624Q0025.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MCFO STEEL FENCE MATERIAL CONTRACT 2023
Item 1. Steel Brace Post (Long) 2-7/8” by 9’ (Quantity 254)
Steel Brace Posts (Long): Shall be 2-7/8” outside diameter, (OD) by 0.217” minimum wall thickness, by 9’ in length, Oil Company Tubular Goods (OCTG) steel pipe. Pipe shall be used/recycled structural OCTG casing or drill pipe in sound structural condition, clean and radiation free (<12 µR/hr.), or new reject pipe, or unused surplus pipe. Surface rust is acceptable; however, any material that is excessively pitted, rusty, flaking, peeling, or corroded will be rejected. Pipe with splits, bends, or thin spots (hot spots) will not be accepted. Pipe shall be free from oil debris. All pipe that is concrete lined, lined with any synthetic material, has holes or perforations shall not be accepted. All drill stem threads and/or collars shall be removed.
Item 2. Steel Brace Post (Short) 2-7/8” by 4’ (Quantity 412)
Steel Brace Posts (Short): Shall be 2-7/8” outside diameter (OD) by 0.217” minimum wall thickness, by 4’ in length, Oil Company Tubular Goods (OCTG) steel pipe. Pipe shall be used/recycled structural OCTG casing or drill pipe in sound structural condition, clean and radiation free (<12 µR/hr.), or new reject pipe, or unused surplus pipe. Surface rust is acceptable; however, any material that is excessively pitted, rusty, flaking, peeling, or corroded will be rejected. Pipe with splits, bends, or thin spots (hot spots) will not be accepted. Pipe shall be free from oil debris. All pipe that is concrete lined, lined with any synthetic material, has holes or perforations shall not be accepted. All drill stem threads and/or collars shall be removed.
Item 3. Steel Brace Rail 2” by 7’ (Quantity 412)
Steel Brace Rail: Shall be a minimum of 7’in length not to exceed 8’ in length, singular piece of round tubular steel constructed with a minimum 1-7/8” outside diameter, by minimum 11-gauge wall thickness. Brace rail ends shall be pressed flat on both ends and be equipped with both a 90- and 45-degree angle capable of being mounted both horizontally as well as diagonally on all bracing structures. Brace banding shall be 2-7/8” heavy duty galvanized brace band, measuring 1” wide by minimum 1/8” wall thickness and supplied with 3/8” galvanized grade five (5) carriage bolts, 1-1/2” to 2” in length with grade five (5) galvanized flange nuts.
Item 4. Drill Stem Mechanical Gate Closer (Quantity 44)
Gate Closer: A36 rolled round steel bar 3/16” to 5/16” diameter or adjustable minimum
3/16” diameter galvanized steel cable wire loop with a minimum Working Load Limit
(WLL) 840 lb. force and Minimum Breaking Load (MBL) 4200 lb. force, fastened to a cam lever device. The pipe cover shall be constructed of a minimum 11-gauge steel plating made to rest upon and exceed the diameter of the 2-7/8” steel brace post.
The mechanical break over latch shall be attached to a minimum of 2-3/8” (OD) by 11-gauge minimum wall thickness tubular steel stem that slides securely into the 2-7/8”
(OD) steel brace post a minimum of 6”. The steel stem shall be radiation free (<12 µR/hr.). The closer must be capable of fitting over a maximum 4” diameter wood gate stay and securely holding the gate stay in place. Alternatives require prior approval by the Contracting Officer (CO) with submission of samples.
Item 5. Gate Loop (Quantity 140)
Gate Loop: A minimum 3/16” diameter galvanized steel cable wire loop with a minimum Working Load Limit (WLL) 840 lb.-force and Minimum Breaking Load
(MBL) 4200 lb. force, attached to a 3” U-bolt muffler clamp assembly and shaped so a maximum 4” diameter gate stay will be securely held in place. The muffler clamp shall be secured to the steel brace post with 9/16” grade five (5) galvanized round U-bolt and galvanized flange nuts. A sleeve shall be welded to the muffler clamp, parallel to a leg of the U-bolt. Another sleeve shall be welded parallel to the other leg of the U-bolt, on the same face of the muffler clamp. The sleeve shall be large enough to allow free movement of the steel galvanized cable but small enough to keep terminated ends from passing through when the loop is under pressure. The galvanized steel cable shall be threaded through the sleeves to form a loop without a bind and the ends shall be crimped with a flattened 9/16” grade five (5) galvanized nut further secured by a weld. Alternatives require prior approval by the CO with submission of samples.