United States Department of the Interior
FWS WEST TENNESSEE REFUGE
234 FT. PRUDHOMME DR
HENNING TN 38041
Lower Hatchie National Wildlife Refuge
Happy Hollow Ditch Project
There are two water control structures and one culvert pipe in the waterfowl that needs to be replaced. These structures have become warped and difficult to insert and remove stop logs and they are leaking; therefore, replacement is needed immediately to meet our waterfowl objectives and general water management. The pipes and structures will need to be delivered by the vendor at 234 Fort Prudhomme Drive Henning, TN 38041. Refuge staff will be installing the structures. The dimensions and cost estimations are as follows:
Structure 1 Description
36" X 10' ALUMINUM FLASHBOARD RISER
- 42' WIDE WEIR
- 3/16" PLATE BACK & BOTTOM
- 1/4" X 2 3/4" X 2" ALUMINUM CHANNEL
- FULL GRATING PLATFORM
- 1/4" X 6" WING & TOE PLATE
-1 36" X 20' 12 GA. ALUMINUM CMP
-2 36" X 30' 12 GA. ALUMINUM CMP
-3 36" PAIRS ALUMINUM FLANGES
Structure 2 Description
24" X 5' ALUMINUM FLASHBOARD RISER
- 36" WIDE WEIR
- 1/4" X 2 3/4" X 2" ALUMINUM CHANNEL
- ANGLES FOR ANCHORING
- FULL GRATING PLATFORM
-2 24" X 20' 14 GA. ALUMINUM CMP
-1 24' PAIR ALUMINUM FLANGES
Straight Pipe
4 48" X 30' 12 GA. 3" X 1" ALUMINUM CMP
3 48" PAIRS ALUMINUM FLANGES
Water Control Structure Drop Off 35 36'37.74"N 89 53'09.31"W