A06_ADDITIONAL_DESCRIPTIVE_AND_MAP.pdf

PDF 350 KB Posted

Attached to
REPLACE HVAC AT 3 UNITS BICY Federal contract opportunity
Solicitation number
140P5223R0021
Issued by
Department of the Interior National Park Service Southeast Region

About this file

This document provides specifications for replacing HVAC systems at three units. The opportunity involves removing existing air handlers and condensing units at three quarters and replacing them with new high-efficiency systems, including a Lennox unit, Trane unit, and relocated Lennox unit. The scope of work specifies installing new supply and return plenums, ductwork, line sets, thermostats, wiring, pads, and other components at each unit. All work must be performed to code and under warranty. The related solicitation is for replacing HVAC at three units located at a National Park Service facility under opportunity number 140P5223R0021.

View the file

Other files for this federal contract opportunity

Other files attached to REPLACE HVAC AT 3 UNITS BICY, newest first.
File Type Posted
Amended_SOL_CLAUSES_0001.pdf PDF
Sol_140P5223R0021_Amd_0001.pdf PDF
A04_BICY_330800A_SOW_Replace_3_HVAC_systems.doc DOC document
B09_QUESTIONNAIRE.pdf PDF
B03_Award_Wages.pdf PDF
Sol_140P5223R0021.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Quarters 21

REMOVE THE EXISTING AIR HANDLER AND CONDENSING UNIT TO

REPLACE IT WITH:

1 NEW LENNOX 20 SEER MODEL NUMBER XC20-036 MATCHED WITH A

CBA38MV-036 VARIABLE SPEED AIR HANDLER WITH ELECTRIC HEAT

NEW SUPPLY PLENUM.

NEW RETURN PLENUM.

NEW AIR HANDLER STAND.

NEW WATER SAFETY SITCHES.

ALL NECESSARY DUCT WORK TO HOOK TO EXISTING DUCT SYSTEM.

ALL NEW DUCT WORK TO BE SEALED PER CODE.

ALL NECESSARY REFRIGERANT PIPING TO HOOK TO EXISTING PIPING.

NEW ARMA FLEX INSULATION ON OUTSIDE SUCTION LINE.

ALL NECESSARY REFRIGERANT PIPING.

NEW REFRIGERANT FILTER DRIER.

LENNOX S-30 ICOMFORT THERMOSTAT.

ALL NECESSARY CONDENSATE PIPING TO HOOK TO EXISTING DRAIN.

NEW SECONDARY DRAIN PAN AND INLINE FLOAT SAFETY SWITCH.

ALL NECESSARY LINE VOLTAGE WIRING TO PROPER ADJACENT

DISCONNECT.

WEATHER RESISTANT VIBRATION PROOF ISOLATION PADS FOR

CONDENSING UNIT.

ALL WORK TO BE PERFORMED IN A PROFESSIONAL MANNER.

WARRANTY: 1-YEAR LABOR 10-YEAR PARTS TO THE PRIGINAL

PURCHASER

Quarters 22

REMOVE THE EXISTING AIR HANDLER AND CONDENSING UNIT TO

REPLACE IT WITH:

1 NEW TRANE 15 SEER PACKAGE UNIT MODEL NUMBER 4TCY5042 WITH

ELECTRIC HEAT

NEW SUPPLY PLENUM.

NEW RETURN PLENUM.

NEW HURRICAN SLAB FOR THE PACKAE UNIT.

ALL NECESSARY DUCT WORK TO HOOK TO EXISTING DUCT SYSTEM.

ALL NEW DUCT WORK TO BE SEALED PER CODE.

DIGITAL THERMOSTAT.

ALL NECESSARY CONDENSATE PIPING.

ALL NECESSARY LINE VOLTAGE WIRING TO PROPER ADJACENT

DISCONNECT.

WEATHER RESISTANT VIBRATION PROOF ISOLATION PADS FOR

CONDENSING UNIT.

ALL WORK TO BE PERFORMED IN A PROFESSIONAL MANNER.

WARRANTY: 1-YEAR LABOR 10-YEAR PARTS TO THE PRIGINAL

Quarters 23

REMOVE THE EXISTING AIR HANDLER AND CONDENSING UNIT TO

REPLACE IT WITH:

1 NEW LENNOX 20 SEER MODEL NUMBER XC20-036 MATCHED WITH A

CBA38MV-036 VARIABLE SPEED AIR HANDLER WITH ELECTRIC HEAT

RELOCATE AIR HANDLER.

RELOCATE CONDENSING UNIT.

NEW COPPER LINE SET.

MODIFY EXISITNG DUCT SYSTEM TO ACCOMMODATE THE NEW AIR

HANDLER LOCATION.

NEW SUPPLY PLENUM.

NEW RETURN PLENUM.

NEW AIR HANDLER STAND.

NEW WATER SAFETY SITCHES.

ALL NECESSARY DUCT WORK TO HOOK TO EXISTING DUCT SYSTEM.

ALL NEW DUCT WORK TO BE SEALED PER CODE.

ALL NECESSARY REFRIGERANT PIPING TO HOOK TO EXISTING PIPING.

NEW ARMA FLEX INSULATION ON OUTSIDE SUCTION LINE.

ALL NECESSARY REFRIGERANT PIPING.

NEW REFRIGERANT FILTER DRIER.

LENNOX S-30 ICOMFORT THERMOSTAT.

ALL NECESSARY CONDENSATE PIPING TO HOOK TO EXISTING DRAIN.

NEW SECONDARY DRAIN PAN AND INLINE FLOAT SAFETY SWITCH.

ALL NECESSARY LINE VOLTAGE WIRING TO PROPER ADJACENT

DISCONNECT.

WEATHER RESISTANT VIBRATION PROOF ISOLATION PADS FOR

CONDENSING UNIT.

ALL WORK TO BE PERFORMED IN A PROFESSIONAL MANNER.

WARRANTY: 1-YEAR LABOR 10-YEAR PARTS TO THE PRIGINAL

***ALL UNITS WILL BE RAISED AT A MINIMUM OF 30 INCHES OFF OF THE GROUND OUTSIDE.

File details come from the government source that posted it. Updated .