This document is a Statement of Work (SOW) for an electrical services contract at the U.S. Fish & Wildlife Service Bend Field Office in Bend, Oregon. The Government has purchased Friant Novo electrical panels and requires an electrician to connect the panels. The key requirements include connecting 4 base infeed, 4 circuit 8 wire panels that can distribute up to 20 amps per circuit, as well as installing ceiling power entry and internal direct connect panels. The electrician must coordinate work hours with local management, minimize dirt and debris, and comply with all applicable codes. The related federal contract opportunity is Solicitation Number 140FC324Q0037, which is for "ELECTRICIAN FOR BEND FURNITURE" for the Department of the Interior Fish and Wildlife Service.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Scope of Work USFWS Bend Field Office

63095 Deschutes Market Rd.

Bend Oregon 97701

Background:

An electrician is needed to connect electrical power wiring and connections to the new furniture that is being assembled at the Bend Field Office in Bend, Oregon.

Scope of Work Requirements: The Government has purchased Friant Novo electrical panels. The purpose of this contract is to connect the panels.

Qty 4 - Base infeed, 4 circuit 8 wire. Each circuit can distribute up to 20 amp.

Hardwire power infeed for use with 4-circuit power distribution.

• Connects building power from a wall, floor or column to the base of a powered System 2 or Novo panel, Interra frame, Beam post, Verity element, or 4-circuit Dash credenza. • Distributes up to four 20-amp circuits. Line IIII is dedicated • Includes a 6’ conduit that can be field-cut to the appropriate length

Ceiling power entry, internal direct connect, 4-circuit.

• Connects a ceiling electrical supply to the base of a powered System 2 or Novo panel, Interra frame, Beam post, or Verity element • Distributes up to four 20-amp circuits. Line IIII is dedicated • Includes a rigid conduit encasing 14’ of wire, factory installed power harness, 12’ pole • Pole can fit (70) cat. 6 cables along with power conduit.

See document “Friant-Power-Manual-12.22.21.pdf “on pages 4-5 that has the circuit wire details and the base feed.

Delivery Address:

U.S. Fish & Wildlife Service Bend Field Office 63095 Deschutes Market Rd.

Bend Oregon 97701

Miscellaneous:

1. If existing equipment or building surface damaged, repair to original specification.

Material used for touch-up and repairs shall blend with the color and texture of surrounding surface and applied in accordance with the manufacturer's recommendations.

2. Work shall include cleanup of work site during and after work to include removal of all unused material, refuse and debris from the work area.

3. Dirt, dust, and debris in the space from the install to be minimized during this work.

4. Work hours must be coordinated with local management.

5. Equipment/material installed shall operate/function as designed by the manufacturer.

6. Contractors shall comply with all applicable zoning and building codes.