This Request for Information (RFI) from the Department of Labor's Mine Safety and Health Administration (MSHA) seeks information about vendors capable of providing SKC Chek-Mate Flowmeter (part number 375-0550NK) for calibrating air flow sample pumps. MSHA requires these flowmeters for essential calibration and flow audits at approximately 10,000 metal/nonmetal mines across the United States and its territories.

The requirement includes delivery to 11 different MSHA locations, with quantities ranging from 2 to 80 units per location, totaling 169 flowmeters. The devices must operate within specific parameters including flow measurement ranges of 20-500 ml/min and 500-5000 ml/min, with accuracy between 1-2.5% depending on flow rate. Responses are due by January 22, 2025, at 5:00 PM ET and must include a one-page cover letter with CAGE code and DUNS number, a five-page technical response, and a one-page past performance summary. Delivery is required within 30 days after receipt of order. The NAICS code is 334519 (Other Measuring and Controlling Device Manufacturing).

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR INFORMATION/SOURCES SOUGHT:

AGENCY/OFFICE: U.S. Department of Labor, Mine Safety and Health Enforcement (MSHA)

LOCATION: Mine Safety and Health Administration Various Locations (see below)

PSC: 6680--Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments

NAICS: 334519-- Other Measuring and Controlling Device Manufacturing

1. GENERAL INFORMATION: The U.S. Department of Labor, Mine Safety and Health Administration (MSHA) is responsible for enforcing health standards promulgated under the authority of Section 103 (a) of the Federal Mine Safety and Health Act of 1977. A national network of MSHA inspectors collects health samples at approximately 10,000 metal/nonmetal mines located in the United States and its territories to monitor miners’ exposures to hazardous contaminants. Mine Safety and Health Administration’s (MSHA’s) Enforcement program is required to conduct periodic atmospheric sampling to confirm that the mine operator has implemented effective controls and to assess approved plan parameters required by the 30 C.F.R.

2. OBJECTIVE: This Request for Information (RFI) is being issued by the U.S. Department of Labor, Mine Safety and Health Administration (MSHA), to provide Chek-Mate Flowmeter part number 375-0550NK specified for essential calibration and flow audits, ensuring that the data collected by the required instruments are accurate and dependable.

3. SCOPE: To procure the SKC Chek-Mate Flowmeter part number 375-0550NK that uses differential pressure flowmeter for calibrating air flow sample pumps at flow ranges between 0.50-5.0 L/min, 20-500 ml/min and 5.0-30.0 L/min.

4. PERIOD OF PERFORMANCE Products are to be delivered within 30 days after receipt of order.

5. PLACE OF PERFORMANCE: Items (as needed) to be shipped to the following locations:

District
Location
Chek- Mates
Barbourville
MSHA 3837 S US HWY 25E Barbourville, KY 40906
7
Beckley
MSHA 1293 Airport Road, Beaver, WV 25813
4
Birmingham
MSHA 1030 London Drive Suite 400 Birmingham, AL 35211
6
Dallas
MSHA Dallas District 1100 Commerce Street Room 462 Dallas, TX 75242
10
Denver
MSHA 1 Denver Federal Center, 6th Ave and Kipling St. Building 25, Dock E-18 Denver, CO 80225
20
Duluth
MSHA 515 W. First St, Rm 323 Duluth, MN. 55802
80
Mt. Pleasant
MSHA Mt. Pleasant District 631 Excel Drive, Suite 100, Mt. Pleasant, PA 15666
8
Norton
MSHA 716 Spring Avenue, SE, Suite 200, Wise, VA 24293
8
Vacaville
MSHA 991 Nut Tree Road, Vacaville, CA 95687
15
Vincennes
MSHA 2300 Willow Street, Suite 200 Vincennes, IN 47591
2
Warrendale
MSHA Warrendale District, 178 Thorn Hill Rd, Suite 100

Warrendale, PA 15086

Note that this is not a request for quotes. A determination by the Government not to compete this requirement based upon responses to this notice is solely within the discretion of the Government. This Request for Information (RFI) seeks industry comments to assist the Government in locating potential sources with the ability to satisfy its requirement. Vendors that believe they can provide the needed services that fully meet the Government's requirements may submit substantiating documentation to determine capability.

6. Response:

Respondents should provide the following information:

A. A one-page cover letter that includes your company’s:

a. CAGE code

b. DUNS Number

c. Business size for the NAICS listed above

d. Contract Point of Contact.

B. Firms will need to provide a response no longer than five (5) pages which addresses each of the Performance Requirements listed in the Draft Statements of Work provided with this announcement.

Each major task(s) requires a written explanation to assess for capability.

Specifications:

Flow Measurement Range
1BLow Flow Chek-mate:

20 to 500 ml/min (volumetric) 2BMedium Flow Chek-mate:

500 to 5000 ml/min (volumetric)

Display Resolution
5B0.001 L/min
Accuracy
7BLow Flow Chek-mate:

20-50 ml/min ± 2.5% of reading

50-500 ml/min ± 1% of reading

Medium Flow Chek-mate:

500-750 ml/min ± 2.5% of reading

750 to 5000 ml/min ± 1% of reading

9BHigh Flow Chek-mate:

5 to 30 L/min ± 1% of reading

Battery
9-V alkaline primary (disposable) PP3 / 6LR61 / 1604A or equivalent, or

8.4V NiMH secondary (rechargeable) PP3 / 6HR61 / 8.4H5 or equivalent

12BAutomatic power off timer – 15 minutes

Operating Temperature Range
132 to 104 F (0 to 40 C)
Operating Barometric Pressure
.700 mbar to 1090 mbar (20.7 inch Hg to 32.2 inch Hg)
Operating Altitude
Sea level to approximately 10,000 ft (3050 m) above sea level
IP Rating (enclosure)
IP40
Overall Dimensions (including hose tail)
.7 x 3.3 x 1.3 in (17.8 x 8.4 x 3.3 cm)
Weight
Models below 9 ounces (255 grams)
Certification
CE Marked

C. Firms shall also provide one page that outlines:

Past government experience (task order/contract) with tasks similar to scope of this draft requirement. Past example should include contract numbers, customer information, and identify point of contacts.

D. Documentation will be evaluated solely for the purpose of determining the availability and potential technical capability of all businesses in providing the requirement.

Submissions should be organized in accordance with the instructions in this document to permit a thorough and accurate review and evaluation. Responses to this RFI must be submitted to Blaine S. Jackson, Contract Specialist via email no later than Wednesday 22 January 2025, at 5:00pm, ET to jackson.blaine.s@dol.gov.

File details come from the government source that posted it. Updated .