A02 - Statement of Work (SOW).pdf
PDF 101 KB Posted
- Attached to
- Headwater Diverson Scour Repair Material
- Solicitation number
- W912EQ21Q0020
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combined Synopsis and Solicitation (W912EQ21Q0020).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work
Scope: The Contractor shall supply and deliver 10,000 TN of R-90 riprap, 2,950 TN of bedding stone, and 1,200 LF of Silt Fencing. Delivery to be on or before 8 April 2021.
Stone Sources:
Stone meeting the requirements of this statement of work has been produced from the sources listed. THE APPROVED STONE SOURCES CAN BE FOUND AT:
http://www.mvm.usace.army.mil/Portals/51/docs/construction/MVDStoneLST.pdf
Service Required, Location: The Contractor will be responsible for the supply and delivery of material to the project location at 3508 Nash Road, Scott City, MO 63780. Any load fees shall be included in the unit price of material. Any additional fees or surcharges for longer haul distances, truck fees, fuel surcharge and/or standby fees shall be included in the unit price of material.
All contractor and all associated sub-contractors employees shall comply with applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative). The contractor shall also provide all information required for background checks to meet installation/facility access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security Office. Contractor workforce must comply with all personal identity verification requirements (FAR clause 52.204-9, Personal Identity Verification of Contractor Personnel) as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any installation or facility change, the Government may require changes in contractor security matters or processes.
All contract employees, including subcontractor employees who are not in possession of the appropriate security clearance or access privileges, will be escorted in areas where they may be exposed to classified and/or sensitive materials and/or sensitive or restricted areas.
Coordination of Work: The Contractor shall coordinate delivery with the following personnel:
The Point of Contact for this effort is Kenneth Burden or Sean Fegette. Mr. Burden can be reached at (901) 634-9857 or by email: Kenneth.L.Burden@usace.army.mil. Mr. Fegette can be reached at (901) 728-7330 or by e-mail: sean.e.fegette@usace.army.mil.
http://www.mvm.usace.army.mil/Portals/51/docs/construction/MVDStoneLST.pdf mailto:Kenneth.L.Burden@usace.army.mil mailto:sean.e.fegette@usace.army.mil
The following are the gradation requirements for bedding material and R-90 Riprap:
R90 Gradation Permissible Limits
Weight of Stone (Pounds) Percent by Weight, Passing 90 100 80 50-100 40 15-50 10 0-15
Gradation for Bedding Material
U.S. Standard Sieve No. Permissible Limits % by Weight, Passing 3-inch 100
1-1/2 inch 85-100 3/4 inch 35-85 3/8 inch 5-40
No. 4 0-10
Statement of Work
File details come from the government source that posted it. Updated .