A02 SOW ISO ATC Toolbox.docx
DOCX document 40 KB Posted
- Attached to
- ATC Toolbox Federal contract opportunity
- Solicitation number
- W50S7E-21-Q-0021
- Issued by
- Department of the Army National Guard
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W50S7E21Q0021 Vendor Questions.docx | DOCX document | |
| Tool listing.pdf | ||
| B01 W50S7E21Q0021 ATC Toolbox.docx | DOCX document | |
| B06 FAR Clause 52_204_24 Representation FILL IN.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MINNESOTA AIR NATIONAL GUARD
HEADQUARTERS 133RD AIRLIFT WING (AMC)
SAINT PAUL MINNESOTA
28 Sep 2021
STATEMENT OF WORK
1. Project Title: 133 MXS Inspection Dock Tool Cabinet
| 2. Project Location: | 133d Airlift Wing |
| Minnesota Air National Guard Base |
685 General Miller Drive St Paul, MN 55111
3. General Scope: The Contractor shall provide an automatic tool control cabinet and startup services needed for inspection dock requirements.
4. Detailed Requirements:
A. 54” Automatic Tool Control Box
· Quantity: 1 each
· To include: Toolbox with at least 9 drawers and approximately 25 individual keys with individually identifiable ID tags for opening and closing the toolbox.
· Toolbox needs to hold approximately 300 tools.
· Toolbox should be a minimum of 54” in order to store the number of tools required.
· Software must report in real time the status of all tools stored within the box.
· Tools must be automatically checked out and turned in when removed from toolbox.
· The software must maintain a current inventory of tools that are in the toolbox.
· The software must track which tools have been removed.
· Software must interface with Air National Guard TC Max Software mandated by AFI 21-101.
· Wi-Fi capable (for standalone communication to other ATC interfaced boxes and lockers, Wi-Fi will be strictly non-network use)
· Toolbox software must be scalable for the addition of other automatic tool control boxes in the future.
· Must be capable of expanding to ethernet networkable on the AF NIPRNET, and scalable with other automatic tool control units
· Includes 110v AC for power.
· Must automatically lock when closed and give a noticeable alert if tools are improperly placed within toolbox or it’s not fully closed.
· Includes RFID and manual key access.
· Includes castors and a push bar.
· Able to track serialized, certified, and calibrated items
· Contractor must image tools and cut toolbox foam to fit the tools that will be placed in the toolbox.
· A list and associated pictures of the tools to be placed in the toolbox will be provided to the contractor.
· Tools cannot be modified to provide tracking
5. Warranty: All materials shall be warranted to be in compliance with this statement of work and to the highest standards of the industry. Minimum warranty of 1 year from date of installation.
Refer technical questions and information to:
MSgt Jason Mosher Contract Speciailist 610 Militia Drive St. Paul, MN 55111 612-713-2612 jason.mosher@us.af.mil image1.png