Minimum Salient Characteristics:

1. QTY (2) Retractable Enclosure Systems

a. Dimensions: 8.5’H x 20’W x 40’L

b. Retracts to 8.5’H x 20’W x 8’L

c. Anteroom 8.5’H x 5’W x 8’L with HEPA filtration

d. Systems: fabricated from fire resistant clear and solid vinyl and heavy walled steel framing

e. Capacity: pulls 18,000 CFM which maintains over the minimum 100 linear feet per minute at the intake filters

f. Support surface: Vinyl and steel framing

g. Height adjustment: 8.5’

h. Portable on casters

i. Design features: fire resistant, retracts to less than 20% of extended length, build on casters for extending and retracting

2. QTY (2) Anteroom

a. Dimensions: 8.5’H x 5’W x 8’L

b. Retracts to less than 20% of the extended length

c. Code compliant galvanized heavy wall tube steel frame

d. Fire rated PVC vinyl in accordance with NFPA 701 (16mil thickness)

e. All vinyl joints are heat welded

f. Design features: Clear PVC vinyl 16 mil.

g. Ceiling mounted HEPA unit for anteroom: SAM24 Haz Loc NCR 2’x 4’ ‐2 units, HEPA Filter, 99.99% @ 0.3μm

3. Installation:

a. Installation in designated locations inside hangars

b. Assist in erecting the enclosure, assembling the air handling unit, and provide training

c. Provide guidance in installing the fire suppression system so it is fully wired through building alarm system.

d. Provide guidance for electrician to wire the controls

e. Two (2) Locations at Fort Campbell, KY

4. Training:

a. To include: how to utilize exhaust system, fire suppression, retract/open system, and change filters.

b. Control panel must be demonstrated on all the uses.