A02_Attachment 0001_SOW.pdf
PDF 158 KB Posted
- Attached to
- 33153 Furnace Services Federal contract opportunity
- Solicitation number
- W519TC25Q2181
About this file
This is a Statement of Work (SOW) for diagnosing burners on a furnace at Rock Island Arsenal Joint Manufacturing Technology Center (RIA-JMTC). The solicitation (W519TC25Q2181) is restricted to Terminal Connections and seeks a contractor to diagnose why the burners on Furnace 19 (Equipment #3000005108) will not hold a constant temperature, with dangerous flame shooting observed. The furnace is a Unitherm Corp Model GPC-48144, located in Building 222 in Rock Island, IL.
Key requirements include dispatching a factory-trained certified technician to diagnose the burner issues, perform necessary lock-out and tag-out procedures, and provide a detailed service report. The contractor must comply with Rock Island Arsenal's security protocols, including registering employees, completing AT Level I training, and obtaining necessary access passes. The service will be performed during 0600-1430 Central Time, with the performance period beginning immediately after contract award. The resultant contract will be a firm-fixed price (FFP) type, and the Service Contract Act Wage Determination #2015-5011 is incorporated by reference.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B08_W519TC25Q2181_Solicitation.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROCK ISLAND ARSENAL DATE: 11 February 2025
SCOPE OF WORK
DIAGNOSE THE BURNERS ON RIA 33153
1. GENERAL:
1.1 Purpose: The purpose of this Scope of Work (SOW) is to provide service to diagnose the burners on Furnace 19, RIA 33153, Equipment# 3000005108 and determine why the furnace will not hold a constant temperature. The furnace is located at the Rock Island Arsenal Joint Manufacturing Technology Center (RIA-JMTC), BLDG 222, in Rock Island, IL 61299-6400.
1.2 Equipment:
RIA 33153, Equipment# 3000005108, Manufacturer Unitherm Corp, Model Number GPC-48144, Serial Number 1089-1
1.3. Security: RIA-JMTC is an Army installation subject to Department of the Defense safeguards, various precautions, and plant protection measures. At all times during the execution of this SOW, the contractor will maintain adequate plant protection devices to minimize espionage, sabotage, and other malicious destruction and damage. At least one week in advance of the scheduled performance period the contractor will register each contracted employee required to perform this SOW at Rock Island Arsenal with the Security Office.
The Contractor shall comply with all security requirements of the Rock Island Arsenal.
1.4. Delivery Hours or Service Hours: Deliveries and service calls will only be allowed from 0600 – 1430 Central Time. These hours are subject to change;
however, the Government will notify the contractor of such changes. The contractor will contact the designated JMTC Representative to obtain an electronic key for their representative (i.e. delivery driver) in order to have access to the facility. Deliveries and service calls outside the normal hours stated above will be coordinated with the JMTC Representative to address any emergency situations.
1.5. PERFORMANCE PERIOD:
Contractor's effort will begin once the contract is awarded.
ROCK ISLAND ARSENAL DATE: 11 February 2025
2. SAFETY AND ENVIRONMENTAL:
2.1. SAFETY: The contractor is responsible for complying with all federal, state, and local safety and environmental regulations, including, but not limited to Occupational Safety and Health Act, Environmental Protection Agency (EPA), Illinois Environmental Protection Agency (IEPA), and Army regulations.
Contractor must adhere to all Rock Island Arsenal Safety requirements, policies and statutes. The contractor shall be responsible for obtaining any hot work/open flame permits required and coordinating with the RIA Fire Department in accordance with (IAW) RIAR 420-2, Chapter #7 – Special Operations, Welding, Cutting and Tar Kettles, specifically Section 7-2, pages 27 and 28. To contact Fire Department for flame permit, contractor shall call (309) 782-5948 or 2911.
2.2. Environmental: All hazardous wastes, acid, and contaminated material generated by the execution of this project will be disposed of IAW all applicable federal, state, and local laws and regulations. All transport and decontamination will be performed IAW all applicable interstate, federal, state, and local laws and regulations. Any materials and/or wastes generated from this effort shall be labeled with appropriate transportation/disposal documentation for off-site disposal to include but not limited to Hazardous waste manifests and associated Land Disposal Restriction. Prior to discussing any environmental issues with the environmental agency of primacy, the contractor shall contact the designated JMTC Representative for direction.
2.3. Ozone Depleting Chemicals (ODCs): The contractor shall assure during execution of the tasks outlined in this SOW that none of the materials used contain Class I ODCs as defined by Public Law 102-484, Section 326.
ROCK ISLAND ARSENAL DATE: 11 February 2025
3.1 Performance Requirements: This SOW is a performance-based specification. The objective of this contract is to diagnose why the burners on the furnace will not hold a consistent temperature. The status of the machine is that the burners will come on, but they are shooting out flames causing a dangerous environment.
3.2. General: The contractor shall be responsible for performing all lock-out and tag-out of equipment. Contractor shall provide all necessary tools, and equipment to perform the full scope of work. At the time of completion, the contractor’s POC shall notify the JMTC Representative the service is complete with the diagnosis of the machine.
3.3. Points of Contact and Notification: At the time of contract award, the contractor shall identify a notification Point of Contact (POC) for service scheduling purposes. The JMTC Representative shall notify the Contractor’s POC to schedule the service requirement when the contract is awarded.
3.4. Qualifications: All work performed under this contract shall be accomplished by a (factory trained) certified technician, repairman or engineer.
The technician, repairman or engineer must be trained to perform service on the equipment requested in the initial designated JMTC Representative notification.
3.5. RIA Assistance: Contractor shall furnish all labor, parts and tools required to perform repairs. JMTC shall assist when possible; however, the contractor should not depend on this assistance.
3.6. Additional: The JMTC Representative shall be notified immediately of any service requirements or parts, which are identified as extraordinary repairs. This would include all parts and services not considered covered in this purchase order. The Contractor shall provide a service report at the completion of each service call. Said report shall contain detailed itemization of all parts and labor.
Report to be legible, either handwritten or electronic (preferred) in a Microsoft Word or Excel format. Reports are to include identification of the servicing technician and should be legible. Service Reports shall be sent to the assigned JMTC Representative.
ROCK ISLAND ARSENAL DATE: 11 February 2025
3.7. Shipping Address: All boxes, parts and components which require shipping shall be accomplished by the servicing technician. Incoming shipment of repair parts shall be made to:
Rock Island Arsenal
Bldg. 299 Recv. Door 16A
Rock Island, IL. 61299-6400
Attn: Nicholas Sallach
Maintenance Crib, Bldg. 220, Floor and a Half
(Include the contract number)
4. INSPECTION/FINAL ACCEPTANCE:
4.1. The JMTC Representative will monitor contractor performance on this Purchase Order in accordance with the Quality Assurance Surveillance Plan (QASP) and the terms and conditions set forth in this SOW.
4.2. Upon machine calibration completion, JMTC Representative will inspect the repaired machine, and, if acceptable, sign the Service Report.
4.3. The JMTC Representative will perform acceptance of service in Wide Area Workflow (WAWF) once the contractor has submitted their invoice and all work is completed.
ROCK ISLAND ARSENAL DATE: 11 February 2025
5. QUALIFICATIONS: When requested, the Contractor shall provide documented evidence that:
5.1. The service technician has at least two (2) years’ experience performing work on Met One (HACH) Particle Counter’s.
5.2. The Contractor possesses the necessary equipment to conduct the services set forth in this SOW.
6. Security training (not needing a CAC)
6.1 AT Level I Training. All contractor employees, including subcontractor employees, requiring access to Army installations, facilities, or controlled access areas shall complete AT Level I awareness training. The JMTC Representative will be provided a copy of the RIA-JMTC AT Level I awareness training and assuring the training is completed. The contractor shall sign a Memorandum of Record for each contractor employee and subcontractor employee to the RIA- JMTC Operations Center prior to a RIA-JMTC electronic keys and access pass being issued.
6.2 Access and General Protection/Security Policy and Procedures.
The contractor and all associated subcontractors’ employees shall provide all information required for background checks to meet installation access requirements to be accomplished by the installation Director of Emergency Services. The contractor workforce must comply with all personal identity verification requirements (FAR clause 52.204-9, Personal Identity Verification of Contractor Personnel) as directed by DoD, HQDA, and/or local policy. In addition to the changes otherwise authorized by the change clause of this contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes.
ROCK ISLAND ARSENAL DATE: 11 February 2025
6.3 For contractors that do not require CAC but require access to a DoD facility or installation.
Contractor and all associated subcontractor employees shall comply with adjudication standards and procedures using the National Crime Information Center interstate identification Index (NCIC-III) and Terrorist Screening Database (TSDB) (Army Directive 2014-05/AR 190-13), applicable installation, facility access and local security policies and procedures (provided by government representative). The JMTC Representative will provide guidance to complete the Access Control Records Check Request Form thru the RIA Directorate of Emergency Services.
6.4 Access Badges and Electronic Keys.
Contractor will acquire and need to return all issued U.S. Government Common Access Cards, installation badges, and/or access passes. Use FAR 52.204-9 or PADDS Clause IF00015 IF00015 at the end of the contract or the last day of an individual contractor’s employment.
6.4.1. RIA-JMTC electronic keys and access passes are accountable items and will be returned within 24 hours of no longer being needed.
Items will return to the JMTC Representative or placed in a drop box at an RIA-JMTC access point.
6.4.2 Contractors who routinely fail to return these items will not be issued them in support of any future contract.
ROCK ISLAND ARSENAL DATE: 11 February 2025
6.5 IWATCH (See Something, Say Something) Training.
The Contractor and all associated subcontractors shall brief all employees on the local iWATCH program. The iWATCH training will be provided in the RIA- JMTC AT training.
6.6 Impact on contractor performance during increased FPCON during periods of increased threat.
During FPCONs Charlie and Delta, services may be discontinued/postponed due to higher threat. Services will resume when FPCON level is reduced to level Bravo or lower. The FPCON descriptions will be provided in the RIA-JMTC AT training.
The JMTC Representative will keep the contractors informed on the current FPCON or any possible FPCON change.
6.7 Random Antiterrorism Measures Program (RAMP) participation.
Contractor personnel working on Rock Island Arsenal are subject to participation in installation RAMP security program (e.g. vehicles searches, wearing of ID badges, etc.). Contractors will comply with any instructions given by the Rock Island Arsenal Police Department. The RAMP program is discussed in the RIA-JMTC AT training.
ROCK ISLAND ARSENAL DATE: 11 February 2025
7. SOFTWARE SUPPORT:
Equipment identified by the JMTC Representative as causing RIA-JMTC to not meet its customers’ orders or security non-compliant shall have the repair service prioritized. RIA-JMTC will have access to software and firmware for accreditation. The contractor will notify JMTC Representative within 15 days of a security update for firmware and or software.
7.1. INFORMATION ASSURANCE AND ACCREDITATION
7.2.1. Information Technology Support Staff.
RIA-JMTC IT Support Staff will be engaged in the event any interaction with RIA-
JMTC information systems or associated computing devices is required. The Contracting Officer Representative (COR) will send a notification to the RIA-JMTC Help Desk (usarmy.RIA.usamc.mbx.ria-jmtc-helpdesk@army.mil) following the scheduling of a vendor visit. This request will notify RIA-JMTC IT Support Staff that there will be an upcoming requirement to accompany the contractor on the scheduled dates. The contractor shall notify their technician that access to the workstation may not be available outside of normal business hours. The technician will be accompanied by an appropriately trained RIA-JMTC IT Support Staff member at all times while at the workstation. RIA-JMTC will not provide the technician credentials to access the workstation. Access to the workstation will be provided by the RIA-JMTC IT Support Staff escort. Removable Media e.g. CD/DVD/USB/SD/External hard drive will be scanned prior to use. Programs and software must be ran from RIA-JMTC approved/provided media or CD/DVD(s). Vendor Devices will not be allowed to connect to the RIA-JMTC network nor will they be allowed to connect to RIA-JMTC equipment other than to scan and transfer media.
mailto:usarmy.RIA.usamc.mbx.ria-jmtc-helpdesk@army.mil
File details come from the government source that posted it. Updated .