S02. Drawing - 2-T2-1 - Partial Second Floor Technology Demo Plan - Phase 2.pdf
PDF 492 KB Posted
- Attached to
- Y1NB--Renovate Operating Rooms - VAMC Cleveland
- Solicitation number
- A0006
About this file
This document contains a drawing for a partial second floor technology demolition plan for Phase 2 of a renovation project at the Veterans Affairs Medical Center in Cleveland, Ohio. The demolition plan shows the locations of existing telecommunications outlets, nurse call devices, conduit, wiring and other low voltage cables to be removed from specific areas during Phase 2 of the project. Notation is made to remove all existing technology equipment, devices and cabling from the project and phase areas back to the existing telecom room, with detailed phasing requirements referred to on drawing 2-E5-1. The related federal contract opportunity posting provides additional details on Solicitation Number A0006 to renovate operating rooms at the VA Medical Center in Cleveland. The addendum extends the bid opening date to September 9, 2020 at noon for this opportunity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06. 36C25020B0022 Amend 0006.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I
P
TV
I I
I
I
I
I
TV TV
T V
T V
TV TV TV
PA
M M
D1
D1
P
I V
C
16C 17B 20A 24C 25B 26B 28B25C
C2
A1
ZZ
YY
XX
UU
RR
ss
B
D
VV
E
G1
C1
17a 24b 25a 26a 28 3119c 23b
X
X
X
X
X X
X
X X
X
XX
X
X
X
X
X
X
X
X X
X
X
X
XX
X
X X
X
X
X
X
X
X X
X
X
X
TYP
TYP
TYP
X
PHASE 2 SCOPE OF WORK
TYP
TYP
TYP
X X
X
P H
A S
E
S C
O P
E O
F W
O R
K
X
X
X X
X
X
X
X
X
X
X
Patient Room #3 (Isolation)
2D127B
Anteroom
2D127A
EMS
Closet
2D110
Gas Room Non
Oxidizing
2514A
Laser Scales Video
Equipment
Toilet
2D127C
Patient Room #5
2D112
Patient Room #4
2D111
Patient Room #2
2D126
Lounge / Dictation
2D251
CRNA
2D253
Corridor
2D250
Women Lockers
2D257A
Surgery Waiting
2D270
Work
2D260D
Work
2D260E
Work
2D260F
Holding
2D260
Holding
Corridor
2500B
Implant Storage
Anesthesia Work Room
Corridor
2500H
OR-7
General
OR-6
General
Electric
EMS
Anesthesia Storage
EMS
2508A
Sub Sterile
Sub Sterile
Dictation
Sterile Storage
General
OR-5
General
OR-4
Storage
OR-3
Orthopedic
Elec.
2517A
Sub Sterile
Sub Sterile
Storage
OR-1
Cardiac
Pump Room
Gas Room Oxidizing
TEMP.
Implant Storage
Rm.
Stair
2S7
Office
Special Equipment Records
OR-2
Neuro
Bed/ Treatment
Room
Medication Prep
Room
Workroom
Corridor
2C100E
Corridor
2500A
Pharmacy
Unisex RR
Corridor
2500J
Corridor
2C280
Foyer
2D255E
Alcove
2D251A
Soiled Utility
2D254
Sterile Supply
2D254A
Locker Room
2D252
Dictation
2D252A
Office
Corridor
2C280
Light Room
2500I
TEMP.
Medical
Prep Rm.
Soiled Elevator
Clean Elevator
Scrub
2500N Scrub
2500O
Upper Mechanical
Room
2500Q
Office
2D261C
Nurse Mgr.
2D262
Control
2D261
PACU
Cubicle 4
2C237D
PACU
Cubicle 3
2C237C
PACU
Cubicle 2
2C237B
PACU
Cubicle 1
2C237A
PACU EMS
2C234 Stair #9
2C202
PACU
Cubicle 5
2C237E
PACU
Cubicle 6
2C237F
Sub-Sterile
2C235
HAC
2C224
Procedure
2C233
Procedure
2C232
Procedure
2C231
Passage
2C230
Staff Women
2B213
Staff Men
2B212
S
59459
M.P. LONG
R
E
S
O F
I
R
G E
NO
I
S
P
E
N
E
D
ERT
L EA
E I N
G
R
T
S
TE
A
H
F OO
IO
FREDRICK, FREDRICK & HELLER
ENGINEERS, INC.
672 EAST ROYALTON ROAD
BROADVIEW HTS., OHIO 44147
TEL. (440) 546-9696
FAX: (440) 546-9699
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1DESIGN AND CONSTRUCTION DOCUMENTS AS
INSTRUMENTS OF SERVICE ARE GIVEN IN
CONFIDENCE AND REMAIN THE PROPERTY OF
PERSPECTUS ARCHITECTURE. THE USE OF THIS
DESIGN AND THESE CONSTRUCTION
DOCUMENTS FOR PURPOSES OTHER THAN THE
SPECIFIC PROJECT NAMED HEREIN IS STRICTLY
PROHIBITED WITHOUT THE EXPRESSED
WRITTEN CONSENT OF PERSPECTUS
ARCHITECTURE. COPYRIGHT C 2019.
13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833
18067
Z M y D o c u m e n ts \1
F F
H C
F R jd u a le .r v t
/2
/2
:0
:4
A
M
2-T2-1
10701 East Blvd. Cleveland, OH 44106
06/26/2020 MPL JRD
541-19-101Renovate Operating RoomsBID ISSUEPARTIAL SECOND FLOOR TECHNOLOGY DEMO
PLAN - PH 2
N
# CODED NOTES
TECHNOLOGY DEMOLITION NOTES
D1 ALL EXISTING TELECOMMUNICATIONS OUTLETS, NURSE CALL DEVICES, CONDUIT, WIRING ETC. THAT WILL NOT BE REUSED IN THE REMODELED INSTALLATION SHALL BE REMOVED UNLESS OTHERWISE NOTED. THIS DEMOLITION SHALL INCLUDE ALL ELECTRICAL ITEMS SHOWN ON THIS PLAN THAT ARE NOT DESIGNATED BY "X", "XN" OR "XRR" AND ALL OTHER ADDITIONAL ITEMS THAT ARE NOT SHOWN BUT THAT MUST BE REMOVED IN ORDER TO PRODUCE A NEAT, FINISHED, PROPERLY FUNCTIONING ELECTRICAL INSTALLATION. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING REUSED ELECTRICAL SYSTEMS COMPONENTS - PROVIDE ALL CONDUIT AND WIRING NECESSARY TO ACHIEVE THE SAME. THE CONTRACTOR SHALL FIELD VERIFY THE NATURE AND EXTENT OF ALL DEMOLITION
WORK AND SHALL INCLUDE COST FOR THE SAME IN THE BID SUBMITTAL.
D2 ALL EXISTING REMOVED TECHNOLOGY EQUIPMENT, DEVICES, ETC. THAT ARE NOT RETAINED BY THE OWNER
SHALL BE DISPOSED OF BY THE ELECTRICAL CONTRACTOR.
D3 DASHED WALLS ON PLAN INDICATE EXISTING CONSTRUCTION TO BE REMOVED.
D4 REFER TO TECHNOLOGY LEGEND FOR ALL SYMBOL DESIGNATIONS. NOTE SPECIAL ATTENTION TO SELECTED EXISTING DEVICES, WIREWAYS, ETC. MARKED XB, XRR OR XN, AND REMOVE/BLANK OFF, RELOCATE OR REPLACE
THESE COMPONENTS AS REQUIRED.
D6 THE TELECOMMUNICATIONS CONTRACTOR SHALL CLOSELY COORDINATE ALL TECHNOLOGY DEMOLITION WORK WITH THE GENERAL AND MECHANICAL CONTRACTORS, AND SHALL DISCONNECT ALL REQUIRED CIRCUITS IN A
TIMELY MANNER.
0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'
1/8" = 1'-0"
PARTIAL SECOND FLOOR TECHNOLOGY
DEMOLITION PLAN - PHASE 2 1
1 REMOVE EXISTING TELECOM OUTLETS, CATV OUTLETS, SPECIAL SYSTEM DEVICES, HORIZONTAL
CABLING, CATV COAX CABLING, AND ANY LOW VOLTAGE CABLES WITH PROJECT/PHASE AREA
COMPLETE BACK TO EXISTING TELECOM ROOM.
REFER TO DRAWING 2-E5-1 "PARTIAL SECOND FLOOR SUBPHASES A,B - PHASE 2" FOR DETAILED
PHASING REQUIREMENTS.
PHASING GENERAL NOTES:
ALL WORK IN PHASE 2 SHALL BE DONE DURING OFF-HOURS. REFER TO THE GENERAL REQUIREMENTS FOR
ADDITIONAL INFORMATION.
1.
Revisions: Date:
Bid Issue 06/26/2020
Addendum 6 08/25/2020
| 18067 FFH CF R19_jduale |
| 2-T2-1 - PARTIAL SECOND FLOOR TECHNOLOGY DEMO PLAN - PH 2 |
File details come from the government source that posted it. Updated .