This sources sought notice from the U.S. Army Corps of Engineers, Savannah District is conducting market research for the repair of Barracks Building M4520 at Fort Bragg, North Carolina. The project involves repairs to the roof, exterior walls, windows, interior walls, doors, insulation, floors, ceilings, plumbing, HVAC, fire protection, and electrical systems. The estimated value is between $10-25 million and the period of performance is 548 days from notice to proceed. Interested parties classified as NAICS 236220 for commercial and institutional building construction must submit capability statements and responses to the market survey no later than July 17, 2022 to the identified contracting officer and specialist. The market research will help determine if the requirement will be set aside for small businesses.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought | Market Survey For

Proj No.: FA-90902-21, Revitalize Building M4520 Fort Bragg, North Carolina

1. The US Army Corps of Engineers (USACE), Savannah District, is conducting market research to identify potential parties that have an interest in and the capability of repairing the roof, exterior walls, windows, interior walls, doors, insulation, floors, ceilings, plumbing, Heating, Ventilation, & Air Condition (HVAC) system, fire protection, and the electrical system. This repair project will incorporate the minimum anti-terrorism and force protection requirements and bring the building to current standards. This project will repair the failed building envelope (roofing, windows, walls, doors); mechanical, electrical, and plumbing systems; and ceilings, floors, and flooring coverings. The project will also remove the continued mold growth and seal rodent entry points into the facility. Hazardous materials (HAZMAT), if found, will be abated according to Federal and State requirements. This project will meet minimum anti-terrorism and force protection requirements.

Based on the responses to this Source Sought Notice/Market Research, this requirement may be set aside for small businesses (in full or in part) or procured through full and open competition. All Small Business Set-Aside categories will be considered. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluation will be provided to companies regarding their submissions. The Government will consider input in determining if a small business set-aside is appropriate for this project when it issues the solicitation package planned for early 4th quarter FY22 with an anticipated award date of 1st quarter FY23.

DISCLAIMER: This Sources Sought is for information only; it is not a request for competitive proposals, quotations, or bids. It does not constitute a solicitation and shall not be construed as a commitment by the Government. Responses in any form are not offers, and the Government is under no obligation to award a contract due to this announcement. No Funds are available to pay for preparing responses to this announcement. Any information submitted by respondents to the announcement is strictly voluntary and will not be returned to the responder. Incomplete answers in any section, failure to provide required or incomplete documents, or providing information outside the scope of this announcement may remove respondents from the Government’s determination of whether to solicit the reference project on a set-aside basis in accordance with Part 19 of the Federal Acquisition Regulation.

Not responding to this notice does not preclude participation in any future request for competitive proposals, quotations, or bids. A solicitation will be synopsized on the Governmentwide Point of Entry (GPE) if a solicitation is released. Potential offerors are responsible for monitoring the GPE for additional information about this requirement.

2. The applicable NAICS code for this requirement is 236220-Commercial and Industrial Building Construction with a Small Business Size Standard of $39.5M. The Product Service Code is Z2FC-Repair of Alteration of Troop Housing Facilities. Businesses of all sizes are encouraged to respond; however, each respondent must identify their business size in their capabilities statement.

3. Construction Magnitude: The estimated magnitude of this construction project is between

$10,000,000 and $25,000,000 (DFARS 236.204).

4. Project Summary: Repairs to barracks building number M4520 with a usable space of

33,962 Square Feet at Fort Bragg, NC, are required to prevent further damage and failure to the failing systems. The building is a three-story housing facility and company operations facility built in 1985.

Abatement and demolition: This project will demolish elements of the building listed in the scope as part of the process to accomplish the repairs. Removed components or systems will be collected and disposed of in a designated location in the waste field. Personnel will not be directly exposed to HAZMAT at any time during the repairs of the facility during its removal and transportation. All safety precautions will be followed during facility restoration according to local and federal regulations.

Architecture: Interior architecture and finishes have failed throughout the building. Paint is peeling, ceiling tiles are sagging and damaged, and floor tiles are broken throughout the building. Windows have peeling paint and evidence of air and water leakage. Mold is present on interior walls. Doors and door hardware are worn. Several cracks are visible in the facade, and the exterior masonry requires pointing.

Electrical: The existing interior electrical systems do not meet current codes and are not adequately sized to support today's everyday electrical demands. Additional receptacles have been added in surface-mounted conduits, and space in electric panels is used. Much of the wiring dates back to the 1980s.

Mechanical: There is evidence of numerous leaks in the HVAC piping systems throughout the building. The main system piping, and valves are corroded and show proof of leaks in the main mechanical room.

Plumbing: Water supply and waste lines have failed. Exposed piping has been repaired, and multiple patches in walls indicate spot repairs to plumbing in chases. Waste lines are cast iron with various sections replaced with PVC and temporary, flexible fittings. Plumbing fixtures use excessive amounts of water beyond current standards. Fixtures are all stained from rust and pipe corrosion. The entire plumbing system has reached a point where piecemeal repairs are no longer effective.

Fire Safety: A fire sprinkler system is currently being repaired as part of the major repair of the facility, according to NFPA 101. Mass notification, central RVAC shutoff, and fire alarm systems are failing.

5. The estimated period of performance for construction is 548 days after issuance of the Notice to Proceed. Specifics regarding the number of option periods, if any, will be provided in the solicitation.

6. Submittal Requirements: All interested parties, with 236220 as an approved NAICS code, are requested to capability statement limited to no more than five (5) pages (excluding attached Market Survey and PLA Determination Tool Responses) in length in Time New Roman font of not less than 10 pitch. This document must address at a minimum the following items:

What type of work has your company performed in the past in support of the same or similar requirement? Include scope, project value, percentage of work you performed, and whether you served as the Prime. (Minimum of three (3) projects)

Can or has your company managed a task of this nature? If so, please provide details.

Can or has your company managed a team of subcontractors before? If so, provide details.

What specific technical skills does your company possess which ensure capability to perform the tasks?

Please note that under a Small-Business Set-Aside, in accordance with FAR 52.219-14, the small business prime must perform at least 15% of the work themselves in terms of the cost of performance. Provide an explanation of your company’s ability to perform at least 15% of the tasking described in this announcement.

Include in your response your ability to meet the requirements in the Facility and

Safeguarding requirements.

7. All responses under this Sources Sought Notice must be emailed to Contract Specialist, SFC

Kassandra Robinson at kassandra.n.robinson@usace.army.mil and cc the Contracting Officer, Mr. Gregory Graham at gregory.m.graham@usace.army.mil no later than July 17, 2022 at 12:00pm Eastern Standard Time. Responses must include a capability statement, responses to the UACE PLA Determination Tool, identification and verification of the company's business size status, and a completed Market Survey Questionnaire which is provided as an attachment to this announcement.

GREGORY M. GRAHAM

Contracting Officer

Attachments:

Market Survey

Sources Sought | Market Survey For

Proj No.: FA-90902-21, Revitalize Building M4520 Fort Bragg, North Carolina

1. Company’s information:

Name: ________________________________________________________

Address (as registered in System for Award Management – SAM):

Point of Contact: __________________________

Phone number: ___________________________

Email address: ___________________________

CAGE Code: ______________

DUNS number: ___________________________

SAM UEI number: ___________________________

2. This market survey applies to work associated with NAICS code 236220 — Commercial and Institutional Building Construction with a size standard of $39.5M, as described in the Sources Sought posting. Respondents to this notice must indicate their business classification. Check all that apply:

( ) Small Business (SB) ( ) Small Disadvantaged Business (SDB) ( ) Veteran Owned (VOSB) ( ) Service-Disabled Veteran Owned (SDVSB) ( ) Women-Owned (WOSB) ( ) Historically Underutilize Business Zone (HUBZone) ( ) 8(a) Program ( ) Other than Small Business (Large Business)

3. Bonding Capability: Per Project*; Aggregate*

*As evidenced by submission of Surety Company letter stating bonding capacity.

Note: Prime contractor must be able to bond for the project amount in its entirety.

4. Interest in providing a proposal, quotation, or bid on any pending solicitation once issued? If no, please submit responses to a and b. ( ) Yes ( ) No

a. If not interested in providing a proposal, quotation, or bid please provide feedback as to why not. Feedback from small business concerns as to why they are not interested is highly encouraged.

b. If as a small business concern, you have a threshold in which you would submit please identify that threshold in your response.

5. In relation to the Project Description:

a. Do you believe all aspects of the project could be performed by the Small Business Sector? ( ) Yes ( ) No If No, please explain areas in which you believe would be challenging for Small Businesses to complete?

b. As a ( ) Large Business / ( ) Small Business, what estimated percentage of the TOTAL project would you self-perform? _______%

c. Please specify/describe which areas are best suited for subcontracting to the small business sector. Also identify your intentions to:

( ) Pursue a Joint-Venture or some other form of teaming agreement ( ) Subcontract Any Work.

d. If a Large Business, what do you think can be subcontracted out to small business?

( ) Small Business (SB) ______% ( ) Small Disadvantaged Business (SDB) ______% ( ) Historically Underutilize Business Zone (HUBZone) ______% ( ) Women-Owned (WOSB) ______% ( ) Veteran Owned (VOSB) ______% ( ) Service-Disabled Veteran Owned (SDVSB) ______%