Bonneville Dam PH1 North Unwatering Sump 3 Specifications

Specifications are for the replacement of a Bingham 6x6 dry pit pump at Bonneville Lock and Dam.

ITEM 1 Submersible Dry Pit Pump (QTY. 1)

Required Operating Conditions and Performance

• 4-inch suction

• 4-inch discharge

• Fluid pumped: Water at 40 degrees F.

• Pump Capacity: 500 GPM @ 115-feet HD

• Submersible Dry Pit Pump

• 460V/ 3 Phase motor with thermal protection and seal leak detection.

• Motor VFD Rated

• Insulation Class: H

• Duty Type: S1

• Frequency: 60-HZ

• 150-foot power cable and 150-foot control cable

• Motor to have all sealed connections and hardware for power cable and control cable

• Self-cleaning semi-open channel impeller

• Modular Based design with high adaptation grade.

• Installation type: T-Vertical Permanent, Dry

• Provide T-Stand for supplied pump

• Impeller Material: Hard-Iron

• 5-year Warranty on motor and pump.

• Current suction line is 6 inch flanged, horizontal direction. New Pump will come with suction kit adaptor for the supplied pump configuration.

• All assembly hardware for stand and suction adaptor will be included, material: 316 stainless steel.