A.02 J 15 02 000 03 Optional equipment Inventory.xlsx
XLSX spreadsheet 34 KB Posted
- Attached to
- Fort Jackson Facility Investment Services Federal contract opportunity
- Solicitation number
- W912HP-20-R-2000
About this file
This document summarizes a pre-solicitation notice and related federal contract opportunity for facility investment and maintenance services at Fort Jackson, South Carolina. The US Army Corps of Engineers, Charleston District intends to issue a request for proposals for preventative maintenance, repair services, and facility investment projects covering approximately 71 buildings totaling over 5 million square feet. Services will include preventative maintenance, service calls, infrastructure sustainment projects, and minimal restoration and modernization work. The acquisition will be a 100% total small business set-aside with a NAICS code of 561210 and size standard of $41.5 million. The contract will be a firm fixed price indefinite delivery indefinite quantity contract awarded for a one year base period and four one-year options with a period of performance through 2026. The pre-proposal conference and site visit details will be provided via future announcement. Prospective offerors should monitor the beta.sam.gov website for the formal solicitation expected before January 30, 2021 with proposals due at least 30 days thereafter.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A.02 J 15 02 000 08 ALMS GFEBS Directions.pdf | ||
| A.02 J 15 02 000 06 GFEBS Role Authorization Form.pdf | ||
| A.02 J 1502000 09 Building Inventory.xlsx | XLSX spreadsheet | |
| A.02 J 15 02 000 02 Service Call History.xlsx | XLSX spreadsheet | |
| A.02 J 02 00 000 12 Employee Background Check Information.pdf | ||
| A.02 DRAFT PWS FIS Fort Jackson 20201204.pdf | ||
| A.02 J-0200000-13 Record of Environmental Consideration.pdf | ||
| A.02 J 0200000 02 Wage Determination 15-4429.txt | TXT text file | |
| A.02 Attachment J-020000-07, -08, -09 ELINs (11.20.20).xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Generators
| FORT JACKSON REAL PROPERTY GENERATORS | |||||||||||||||||
| Building Number | Serviced By | Specific Location | Building Function | Engine Manufacturer | Engine Model Number | Engine Serial Number | Genset Manufacturer | Genset Model Number | Genset Serial Number | Fuel | Generator Output (kW) | Engine HP | Manufacture Date | Stack configuration | |||
| (vertical, horizontal) | Associated Fuel Storage Tank | ||||||||||||||||
| (AST, UST or None) | Capacity | ||||||||||||||||
| (gallons) | Needed Service | ||||||||||||||||
| 2400 | DPW | Behind building | Headquarters | Cummins | TD400-01 | P-8376 | Diesel | 400 | 536 | Jun-15 | AST | In addition to regular maintenance, the following services need to occur: |
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 2609 DPW Behind building, inside fence NEC Mitsubishi 4D34-T(?) Unknown Generac 3931290100 2076879 Diesel 60 80 Apr-04 Vertical AST Unknown In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 3100 DPW Next to building, inside fence NEC Cummins Unknown Unknown Cummins DSFAE-7295859 F110221737 Diesel 80 107 Jun-11 Vertical AST Unknown In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson J4236 DPW Next to building, inside fence NEC Mitsubishi 4D34-T 0D5825 Generac 3617980100 2074860 Diesel 80 107 Nov-03 AST In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 4282 DPW Behind building NEC Cummins Q5X15-G9 79635574 Cummins DFEH-1220445 A130452520 Diesel 354 475? Jan-13 AST In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 5499 DPW N/A EMS/Fire Department Cummins GTA855C1 25273798 Elliot Power Systems 180RN BX01J193 Natural Gas 180 293 Nov-01 Vertical None N/A In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect spark plugs every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 5615 DPW Behind building, inside fence NEC Cummins QSM11-G4NR3 2003245 Cummins DQHAB-8086897 J110256725 Diesel 300 402 Sep-11 Vertical AST 600 In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 12020 DPW N/A NEC Cummins Unknown Unknown Cummins DSFAE-7295845 F110221739 Diesel 80 107 Jun-11 Vertical AST Unknown In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson JRR DPW Johnson Rifle Road NEC Unknown Unknown Generac 14861230100 2118091 Diesel 50 67 Dec-16 Vertical AST Unknown In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 7533 DPW N/A Emergency Operations Center (EOC) MTU 6R1600G70S 16301001230 MTU/Marathon Electric 433PSL6216 MX159004 PH Diesel 275 369 2010 AST In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson
USTs
| FORT JACKSON UNDERGROUND STORAGE TANKS | ||||||
| USTs | Bldg No | No. | Type | Capacity (gal) | Permit No. | Services needed. |
| Gate 1 Shoppette | 2420 | 1 | Gasoline (Reg) | 12000 | 18458 | 1. Regular maintenance and repair as needed. |
2. Annual line and tank tightness testing.
3. Veeder Root leak detector tests
4. Overfill protection system tests.
5. All sensors inspected and checked.
| Gate 1 Shoppette | 2420 | 2 | Gasoline (Reg) | 12000 | 18458 | |
| Gate 1 Shoppette | 2420 | 3 | Gasoline (Prem) | 12000 | 18458 | |
| Gate 1 Veeder Roort System 450 Plus | ||||||
| Gate 2 Shoppette | 4120 | 1 | Gasoline (Reg) | 12000 | 13033 | 1. Regular maintenance and repair as needed. |
2. Annual line and tank tightness testing.
3. Veeder Root leak detector tests
4. Overfill protection system tests.
5. All sensors inspected and checked.
| Gate 2 Shoppette | 4120 | 2 | Gasoline (Reg) | 12000 | 13033 |
| Gate 2 Shoppette | 4120 | 3 | Gasoline (Reg) | 12000 | 13033 |
| Gate 2 Shoppette | 4120 | 4 | Gasoline (Prem) | 12000 | 13033 |
ASTs
| FORT JACKSON ABOVEGROUND STORAGE TANKS | |||||
| Bldg No | No. | Type | Capacity (gal) | Description | Notes |
| 2400 | Diesel | 2025 | HQ | ||
| 2609 | Diesel | ≈200 | NEC | ||
| 3100 | Diesel | ≈200 | NEC | ||
| 4282 | Diesel | 3000 | NEC | Needs painting, labeling and integrity testing. | |
| 5615 | Diesel | ≈450 | NEC | ||
| 7533 | Diesel | 1000 | Emergency Operations Center (EOC) | ||
| 12020 | Diesel | ≈200 | NEC | ||
| JRR | Diesel | ≈200 | NEC | ||
| J4237 | Diesel | ≈200 | NEC |
OWS
| FORT JACKSON OIL WATER SEPERATORS | |||||||||||||
| Building | Organization | Sediment Trap/ Grit Chamber | Location | Type | Configuration | Construction Material | Accessibility (Top Of Tank) | OWS Size | Holding capacity | Alarm | Effluent Discharge To: | Recommend Cleaning Frequency | Recommend Cleaning |
| 2604 | TACOM Motor Pool | NO | OWS west of building | Standard Gravity | Cylindrical | Steel | Closed w/ manholes (Bolted) | ***** | ***** | Yes | Sanitary sewer POTW | Annually | OWS |
| 2607 | DPW Bus Wash | YES | OWS located immediately west of bus wash rack building. (location also has Grit Chamber located west of bus wash) | Coalescing Standard Gravity-Parallel plates/ Corrugated Plates | Cylindrical | Steel | Closed w/ manholes (Bolted) | 350 gallons | 140 gallons | Yes | Sanitary sewer POTW | Annually | OWS & Grit Chamber |
| 2610 | DPW/ LRC maintenance Complex | NO | OWS located next to wash rack | Coalescing Standard Gravity-Parallel plates/ Corrugated Plates | Cylindrical | Steel | Closed w/ manholes (Bolted) | 2000 gallons | 800 gallons (Integral) | Yes | Sanitary sewer POTW | Annually | OWS |
| 5669 | FMWR Autocraft Shop | NO | OWS at west end of building | Standard Gravity | Rectangular | Reinforce Concrete | Closed w/ manhole | 1000 gallons | ? | No | Sanitary sewer POTW | Annually | OWS |
| 5672 | Car Wash | NO | Not yet installed | Expected to be Standard Gravity | Expected to be Rectangular | Reinforced Concrete | Closed w/ manhole | Approx 1500 gal | ? | Yes | Sanitary sewer POTW | Semiannual | OWS |
| 9408 | AMC/ Tacom Motor Pool | NO | OWS south of wash rack | Coalescing Standard Gravity-Parallel plates/ Corrugated Plates | Cylindrical | Steel | Closed w/ manholes (Bolted) | 2000 gallons | 800 gallons (Integral) | No | Sanitary sewer POTW | Annually | OWS |
&"Arial Narrow,Bold"&24&K03+000 Fort Jackson OWS and Washrack Inventory
Washracks
| FORT JACKSON WASH RACKS | ||||||
| Building | Organization | Sediment Trap/ Grit Chamber | Location | Effluent Discharge To: | Recommend Cleaning Frequency | Recommend Cleaning |
| 2607 (Bus wash) | DPW Bus Wash | YES | Location also has Grit Chamber located west of bus wash) | Sanitary sewer POTW | Annually | Washrack |
| 2610 (Washrack) | DPW/ LRC maintenance Complex | Yes | OWS located next to wash rack | Sanitary sewer POTW | Annually | Washrack |
| 9408 (Washrack) | AMC/ Tacom Motor Pool | NO | OWS south of wash rack | Sanitary sewer POTW | Annually | Washrack |
| Services to the wash rack shall be to clean the wash rack area so that it is free so debris, the sediment trap/grit chamber is pumped out, cleaned and that no debris remains after servicing. |
&"Arial Narrow,Bold"&24&K03+000 Fort Jackson OWS and Washrack Inventory
Crane
| FJ Overhead Cranes | |||||||
| Building | Hoist Manufacturer | Crane Manufacturer | Crane Type | Rated Capacity | Span | Lift | Voltage |
| 2602 | Yale | RJ Mack | UHSG | 7.5 ton | 54 ft | 20 ft | 460 |
| 2602 | R&M | Cleveland Tamrail | UHSG | 2 ton | 18 | 15 | 230 |
| 2603 | Yale | RJ Mack | UHSG | 7.5 ton | 54 ft | 20 ft | 460 |
| 2603 | Yale | RJ Mack | UHSG | 7.5 ton | 54 ft | 20 ft | 460 |
| 2604 | Yale | RJ Mack | UHSG | 7.5 ton | 54 ft | 20 ft | 460 |
| 2604 | UNKNOWN | UNKNOWN | UNKNOWN | UNKNOWN | UNKNOWN | UNKNOWN | UNKNOWN |
image1.emf image2.emf image3.emf image4.emf