OH DR
RECEIVING
OH DR
MEZZANINE
C R
I B
OH DR
OH DR
OH DR
OH DR OH DR
O H
D
R
INDIVIDUAL
ISSUE
VAULT
OFFICE
OFFICE
BREAK
ROOM
BATT
STORE
STORE
STORAGE &
ISSUE
HAZ.
STORE
MECHNICAL
ROOM
DELIVERY,
RECEIVING &
INSPECTION
OFFICE
PACKING,
CRATING &
AIRLOG
OFFICE
PASSAGE
OH DR
MODULAR
OFFICE
MODULAR
OFFICE
MODULAR
OFFICE
MODULAR
OFFICE
MODULAR
OFFICE
RAMP
RAMP
10'-4"
12'-4"
N
T
I
N
C
N
T
R
A
C
T
C
A
I
GENERAL NOTES
1. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. ALL DIMENSIONS AND
CONDITIONS ARE TO BE VERIFIED IN FIELD BY THE CONTRACTOR.
2. CONTRACTOR SHALL NOT PAINT EXISTING STEEL STRUCTURE OR EXTERIOR
METAL PANELS.
3. CONTRACTOR SHALL PROTECT ALL ADJACENT EQUIPMENT FROM OVER SPRAY
AND DRIPS.
KEYNOTES:
A. PAINT LOW WALL AT PERIMETER OF RECEIVING PLATFORM (PNT-1). PRESERVE
SAFETY AND CAUTION MARKINGS. IF MARKINGS ARE PAINTED OVER,
CONTRACTOR IS RESPONSIBLE FOR REPLACING/REPAINTING MARKINGS.
B. PAINT HAND RAILS AND ALL ASSOCIATED PARTS. (PNT-5)
C. PAINT MAN DOORS AND ASSOCIATED TRIM COMPLETE (PNT-3)
D. PAINT WINDOW FRAME, AND ASSOCIATED TRIM COMPLETE (PNT-3)
E. PAINT OVER HEAD DOOR AND ASSOCIATED TRIM COMPLETE (PNT-3)
F. PAINT WALL. PAINT WALL AND WALL MOUNTED ACCESSORIES IN A MANNER
THAT ALLOWS FOR PROPER OPERATION ONCE PAINT DRIES. WALL SHALL BE
(PNT-1) BELOW 8'-6" AFF. WALL SHALL BE (PNT-2) ABOVE 8'-6" AFF. ALL A
COORDINATE WITH GOV'T TO ARRANGE MOVEMENT OF THE ITEMS STORED
ALONG THE WALL. SEE ASSOCIATED DETAIL 02, THIS SHEET.
G. PAINT WALL ABOVE MODULAR OFFICE EQUIPMENT. OFFICE EQUIPMENT. (PNT-2)
H. PAINT PARTIAL WALL ABOVE BREAK ROOM. (PNT-2) STRUCTURE BELOW MAY
NOT BE ABLE TO SUPPORT PERSONNEL. PLAN ACCORDINGLY.
I. MODULAR OFFICE FURNITURE/EQUIPMENT NOT TO BE PAINTED. CONTRACTOR
SHALL PROTECT FROM OVER SPRAY AND DRIPS.
J. EXISTING INSULATED METAL SIDING. NOT TO BE PAINTED, DEEP CLEAN AND
PROTECT FROM PAINT OVER SPRAY AND DRIPS.
K. APPROXIMATE LOCATION OF COLUMN. DEEP CLEAN AND REPAINT COLUMN AND
ATTACHED STRUCTURE BELOW 17' AFF AND WHERE ACCESSIBLE (PNT-4). COLOR
MATCH WILL BE REQUIRED.
L. PAINT 8" LINES DELINEATING EXTERIOR LIMITS OF RECEIVING BAY EXTERIOR
ROLL UP DOORS. HATCH IN AREA BETWEEN LINES WITH 6" PAINTED LINES. LINES
SHALL BE OF AN APPROPRIATE TYPE OF PAINT (PNT-5) AND SHALL TRAVEL AT 45
DEGREE ANGLE.
M. PAINT SIDES OF MTL DOCK RAMP WITH APPROPRIATE PAINT. (PNT-5)
N. APPROXIMATE LOCATION OF EYE WASH STATION. PAINT WITH APPROPRIATE
PAINT. (PNT-5)
O. PAINT LOUVER AND ASSOCIATED TRIM COMPLETE (PNT-3)
C
C
C
C
C
C
C
C
C
C
C
C
E
E E
E
E
C
C
E
C
E
D
B
EE
E E E
VGLZ182014
BLDG. 105 &
BLDG. 24
PAINT
FINISH
FLOOR PLAN
1 1
NOTES:
BUILDING 105 - FLOOR PLAN
SCALE: 1' = 1/6"
A-401
A-401
BUILDING 24 - FLOOR PLAN
SCALE: 1' = 1/6"
A-401
PAINT COLORS
COLOR # COLOR NAME
PNT-1 COLOR TBD
PNT-2
SHERWIN WILLAMS, SW 7004 "SNOW BOUND"
PNT-3
SHERWIN WILLAMS, SW 2012 "WARM SHADOW"
PNT-4
GLIDDEN 79-64 "DARK BROWN" (COLOR MATCH EXISTING)
PNT-5
SHERWIN WILLIAMS, SW 4048 "SAFETY YELLOW"
I
I
I
D
D
K
TYP
K
TYP
K
TYP
K
TYP
J
TYP
K
F
LLLL
B BM
N
J
TYP
J
TYP
TYP
J
TYP
F
O
O O
O
H
H
F
TYP
F
F
F
F
F
F
F
F
F
TYP
TYP
TYP
TYP
F
TYP
F
TYP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WORK BAY
AutoCAD SHX Text
LOCKER ROOM
AutoCAD SHX Text
LOCKER ROOM
AutoCAD SHX Text
BREAK ROOM
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
BOILER ROOM
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
WASH BAY
AutoCAD SHX Text
COMPRESSOR ROOM/ TEST CELL
AutoCAD SHX Text
WORK BAY/ TEST CELL
AutoCAD SHX Text
WASH BAY
AutoCAD SHX Text
WORK BAY/ TEST CELL
AutoCAD SHX Text
HAZMAT ROOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
105 SF
AutoCAD SHX Text
105 SF
AutoCAD SHX Text
4,925 SF
AutoCAD SHX Text
319 SF
AutoCAD SHX Text
319 SF
AutoCAD SHX Text
319 SF
AutoCAD SHX Text
319 SF
AutoCAD SHX Text
319 SF
AutoCAD SHX Text
319 SF
AutoCAD SHX Text
ELEC ROOM
AutoCAD SHX Text
COMM ROOM
AutoCAD SHX Text
MEN
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text F
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text Sheet Title
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text 127th WING/CIVIL ENGINEER
AutoCAD SHX Text Engineer/Consultants
AutoCAD SHX Text
SELFRIDGE AIR
AutoCAD SHX Text
NATIONAL GUARD
AutoCAD SHX Text
BASE, MICHIGAN
AutoCAD SHX Text Project Number:
AutoCAD SHX Text File:
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text Designed By:
AutoCAD SHX Text Checked By:
AutoCAD SHX Text
A. VERMEERSCH
AutoCAD SHX Text xxxxxxx.dwg
AutoCAD SHX Text
VGLZ 000000
AutoCAD SHX Text Mark
AutoCAD SHX Text Date
AutoCAD SHX Text Description
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text Scale:
AutoCAD SHX Text 1/16:=1'-0"
AutoCAD SHX Text Date:
AutoCAD SHX Text 20200505
AutoCAD SHX Text
1. THE PLAN AND UNDERGROUND THE PLAN AND UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE GOVERNMENT MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN-SERVICE OR ABANDONED. THE GOVERNMENT FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM AVAILABLE INFORMATION.
AutoCAD SHX Text
A. VERMEERSCH
AutoCAD SHX Text
A. VERMEERSCH