A-3 COMBINED DRAWINGS - WA ANG B456.pdf
PDF 11 MB Posted
- Attached to
- B456 HVAC Repair Federal contract opportunity
- Solicitation number
- W50S9D-24-B-5001
- Issued by
- Department of the Army National Guard
About this file
This file contains technical drawings related to a federal contract opportunity for HVAC repair services. The solicitation number is W50S9D-24-B-5001 and is being issued by the Department of the Army National Guard for repairs to the HVAC system at facility B456. The pre-solicitation opportunity involves repair and maintenance of existing HVAC equipment as detailed in the combined drawings file, which contains system diagrams and specifications. Responses are due based on the standard solicitation timeline.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A-3 COMBINED SPECIFICATIONS - WA ANG B456.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MICHELLE
YVONNE
HIDLE
NO. C 38085
REN. 03-31-2023
C
E
TE
A S
T
I C L
FF LAO I
AI
O
NR
H N
DSE CAR
I T
TC
E
02/11/2022
AS AGENT OF AECOM
C
B
A
13 24
C
B
A
13 24
REGISTRATION
La st
P lo tte d:
Fi le na m e:
Printed on Post-Consumer Recycled Content Paper
AN
SI
D
2" x3
4" Pr oj ec t M an ag em en t I ni tia ls
D es ig ne r:
C he ck ed
Ap pr ov ed
©2022 AECOM Corporation
ISSUE/REVISION
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
CLIENT
A-E
A-1 SUBMITTAL (10%)08/12/2019
A-2 SUBMITTAL (35%)02/17/2020
A-2 RESUBMITTAL (35%)04/17/2020
B-1 SUBMITTAL (65%)07/14/2020
PROJECT
FAIRCHILD AIR FORCE BASE
REPAIR HVAC B456
B-2 SUBMITTAL (95%)12/03/2020
60604048
B-3 SUBMITTAL (100%)02/11/2022
1/
/2
9:
:3
PM
BI
M
-W
A
AN
G H
VA
C
B
B4
/6
8-
W A
AN
G
B
6_ A-
.rv t D
M
YH
LC
D
COVER SHEET
G-001G -0
-C
O
VE
R S
H
EE
T
Architecture
AECOM
999 Town & Country Rd Orange, CA 92868
HTTP://AECOM.COM
Washington Air National Guard 141st Air Refueling Wing Fairchild Air Force Base Spokane County, WA
TEL(509) 247-7003
HTTP://www.141arw.ang.af.mil/
Architectural
AECOM
401 West A Street Suite 1200 San Diego, CA 92101
HTTP://AECOM.COM
REPAIR HVAC BUILDING 456,
SERVICES
FAIRCHILD AIR FORCE BASE, WASHINGTON
WASHINGTON AIR NATIONAL GUARD
141ST AIR REFUELING WING
ANG PROJECT NUMBER: GJKZ152865
AECOM PROJECT NUMBER: 60604048
FY2022
B-3 SUBMITTAL
100% DESIGN
02-11-2022
LOCATION MAP
VICINITY MAP
PROJECT SITE
FAIRCHILD AFB
I/R DATE DESCRIPTION
MICHELLE
YVONNE
HIDLE
NO. C 38085
REN. 03-31-2023
C
E
TE
A S
T
I C L
FF LAO I
AI
O
NR
H N
DSE CAR
I T
TC
E
02/11/202
C
B
A
13 24
C
B
A
13 24
REGISTRATION
La st
P lo tte d:
Fi le na m e:
Printed on Post-Consumer Recycled Content Paper
AN
SI
D
2" x3
4" Pr oj ec t M an ag em en t I ni tia ls
D es ig ne r:
C he ck ed
Ap pr ov ed
ISSUE/REVISION
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
CLIENT
A-E
A-1 SUBMITTAL (10%)08/12/2019
A-2 SUBMITTAL (35%)02/17/2020
A-2 RESUBMITTAL (35%)04/17/2020
B-1 SUBMITTAL (65%)07/14/2020
PROJECT
FAIRCHILD AIR FORCE BASE
REPAIR HVAC B456
B-2 SUBMITTAL (95%)12/03/2020
60604048
B-3 SUBMITTAL (100%)
/2
9:
:3
PM
BI
M
-W A
AN
G
H
VA
C B
B4
/6
8- W
A
AN
G B
6_
A-
.rv t
D M
YH
LC
D
SHEET INDEX
G-002G -0
-S
H
EE
T
IN
D
EX
MICHELLE
YVONNE
HIDLE
NO. C 38085
REN. 03-31-2023
C
E
TE
A S
T
I C L
FF LAO I
AI
O
NR
H N
DSE CAR
I T
TC
E
AS AGENT OF AECOM
C
B
A
13 24
C
B
A
13 24
REGISTRATION
La st
P lo tte d:
Fi le na m e:
Printed on Post-Consumer Recycled Content Paper
AN
SI
D
2" x3
4" Pr oj ec t M an ag em en t I ni tia ls
D es ig ne r:
C he ck ed
Ap pr ov ed
©2022 AECOM Corporation
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
CLIENT
A-E
A-1 SUBMITTAL (10%)08/12/2019
A-2 SUBMITTAL (35%)02/17/2020
A-2 RESUBMITTAL (35%)04/17/2020
B-1 SUBMITTAL (65%)07/14/2020
PROJECT
FAIRCHILD AIR FORCE BASE
REPAIR HVAC B456
B-2 SUBMITTAL (95%)12/03/2020
60604048
B-3 SUBMITTAL (100%)02/11/2022
1/
/2
9:
:3
PM
BI
M
-W
A
AN
G H
VA
C
B
B4
/6
8-
W A
AN
G
B
6_ A-
.rv t D
M
YH
LC
D
SHEET INDEX
G-002G -0
-S
H
EE
T
IN
D
EX
Architecture
AECOM
999 Town & Country Rd Orange, CA 92868
HTTP://AECOM.COM
Washington Air National Guard 141st Air Refueling Wing Fairchild Air Force Base Spokane County, WA
TEL(509) 247-7003
HTTP://www.141arw.ang.af.mil/
Architecture
AECOM
999 Town & Country Rd Orange, CA 92868
HTTP://AECOM.COM
Washington Air National Guard 141st Air Refueling Wing Fairchild Air Force Base Spokane County, WA
TEL(509) 247-7003
HTTP://www.141arw.ang.af.mil/
Architectural
AECOM
401 West A Street Suite 1200 San Diego, CA 92101
HTTP://AECOM.COM
Architectural
AECOM
401 West A Street Suite 1200 San Diego, CA 92101
HTTP://AECOM.COM
SCHEDULE - SHEET INDEX
- SUBMISSIONS
NUMBER NAME A-2 (35%) B-1 (65%) B-2 (95%) B-3 (100%)
GENERAL
G-001 COVER SHEET X X X X
G-002 SHEET INDEX X X X X
STRUCTURAL
S-001 STRUCTURAL NOTES X X X
S-002 STRUCTURAL NOTES X X X
S-003 TYPICAL DETAILS X X
S-004 TYPICAL DETAILS X X
S-110 STRUCTURAL FLOOR PLAN - FIRST FLOOR X X X
S-401 MECHANICAL YARD PLAN X X X
S-402 STRUCTURAL FLOOR PLAN (BID OPTION) X X
S-403 STRUCTURAL ROOF PLAN (BID OPTION) X X X
S-404 MECHANICAL YARD FOUNDATION PLAN (BID OPTION) X X
S-405 MECHANICAL YARD ROOF FRAMING PLAN (BID OPTION) X X X
S-501 STRUCTURAL DETAILS X X
S-502 STRUCTURAL DETAILS X X
ARCHITECTURE
A-001 ARCHITECTURAL GENERAL NOTES, ABBREVIATIONS X X X X
AD101 DEMOLITION RCP - FIRST FLOOR X X X X
A-110 COMPREHENSIVE FLOOR PLAN - FIRST FLOOR X X X X
A-111 FIRST FLOOR PLAN - AREA A X X X
A-112 FIRST FLOOR PLAN - AREA B X X X
A-113 FIRST FLOOR PLAN - AREA C X X X
AR110 COMPREHENSIVE RCP - FIRST FLOOR X X X
AR111 FIRST FLOOR RCP - AREA A X X X
AR112 FIRST FLOOR RCP - AREA B X X X
AR113 FIRST FLOOR RCP - AREA C X X X
A-201 ELEVATIONS - NORTH AND SOUTH X X X X
A-202 ELEVATIONS - EAST AND WEST X X X X
A-301 BUILDING SECTIONS X X X X
A-401 MECHANICAL ENCLOSURE - PLAN & DETAILS X X
A-402 MECHANICAL ENCLOSURE - ELEVATIONS & DETAILS X X
A-403 (ABI) MECHANICAL ENCLOSURE - PLAN & DETAILS X X X
A-404 (ABI) MECHANICAL ENCLOSURE - ELEVATIONS X X
A-405 (ABI) STOREFRONT REPLACEMENT - PLAN & DETAILS X X X
A-501 DETAILS, CEILING X X X
A-502 DETAILS, DUCT PENETRATION X X
A-503 DETAILS, DUCT PENETRATION X X
A-601 DOOR & WINDOW SCHEDULE X X X X
A-610 (ABI) DOOR & WINDOW TYPES & DETAILS X X X
A-611 (ABI) DOOR & WINDOW DETAILS X X
MECHANICAL
M-001 MECHANICAL ABBREVIATIONS, LEGENDS, SYMBOLS, & NOTES X X X X
M-002 MECHANICAL SCHEDULES X X X X
MD-100 COMPREHENSIVE HVAC DEMO PLAN - FIRST FLOOR X X X X
MD-101 HVAC FIRST FLOOR DEMO PLAN - AREA A X X X X
MD-102 COMPREHENSIVE PLUMBING DEMO PLAN - FIRST FLOOR X X X X
MD-103 PLUMBING FIRST FLOOR DEMO PLAN - AREA A X X X X
M-100 COMPREHENSIVE HVAC FIRST FLOOR PLAN X X X X
M-101 HVAC FIRST FLOOR PLAN - AREA A X X X X
M-102 HVAC FIRST FLOOR PLAN - AREA B X X X X
M-103 HVAC FIRST FLOOR PLAN - AREA C X X X X
M-300 MECHANICAL SECTIONS X X X X
M-500 MECHANICAL DETAILS X X X X
M-700 MECHANICAL CONTROL DIAGRAMS X X X X
M-701 MECHANICAL CONTROL DIAGRAMS X X
MP-100 COMPREHENSIVE PLUMBING FLOOR PLAN - FIRST FLOOR X X X X
MP-101 PLUMBING FIRST FLOOR PLAN - AREA A X X X X
ELECTRICAL
E-001 ELECTRICAL ABBREVIATIONS, LEGENDS, SYMBOLS, & NOTES X X X X
ED-100 ELECTRICAL DEMO PLAN - FIRST FLOOR X X X X
ED-700 ELECTRICAL SINGLE LINE DIAGRAM - DEMO X X X X
E-100 COMPREHENSIVE ELECTRICAL FLOOR PLAN - FIRST FLOOR X X X X
COMPREHENSIVE ELECTRICAL LIGHTING FLOOR PLAN - FIRST FLOOR X X X X
I/R DATE DESCRIPTIONI/R DATE DESCRIPTION
E-700 ELECTRICAL SINGLE LINE DIAGRAM X X X X
E-105
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
ADAHA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
OF CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
C
B
A
13 24
C
B
A
13 24
REGISTRATION
L a s t
P lo tt e d
F ile n a m e
Printed on Post-Consumer Recycled Content Paper
A N
S I
D
"x
P ro je c t
M a n a g e m e n t
In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
©2022 AECOM Corporation
ISSUE/REVISION
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
CLIENT
A-E
A-1 SUBMITTAL (10%)08/12/2019
A-2 SUBMITTAL (35%)02/17/2020
A-2 RESUBMITTAL (35%)04/17/2020
B-1 SUBMITTAL (65%)07/14/2020
PROJECT
FAIRCHILD AIR FORCE BASE
REPAIR HVAC B456
B-2 SUBMITTAL (95%)12/03/2020
60604048
B-3 SUBMITTAL (100%)02/11/2022
/2
/2
:5 :5
P
M
B
IM
/6
-W A
A N
G H
V A
C B
B
/6
-W A
A N
G B
S -1
.r v t
P A
P A
L D
STRUCTURAL NOTES
S-001S -0
-S T
R U
C T
U R
A L
N O
T E
S
Architectural
AECOM
999 Town & Country Rd Orange, CA 92868
HTTP://AECOM.COM
Washington Air National Guard 141st Air Refueling Wing Fairchild Air Force Base Spokane County, WA
TEL(509) 247-7003
HTTP://www.141arw.ang.af.mil/
Architectural
AECOM
401 West A Street Suite 1200 San Diego, CA 92101
HTTP://AECOM.COM
GENERAL
1. DESIGN CODES AND GENERAL REQUIREMENTS:
A. UNIFIED FACILITIES CRITERIA (UFC) OCT 2016
B. WASHINGTON BUILDING CODE WITH LOCAL AMENDMENTS (2015).
C. FEDERAL OCCUPATIONAL SAFETY AND HEALTH STANDARDS ACT.
D. INTERNATIONAL BUILDING CODE (2015).
E. ALL OTHER STATE, LOCAL, AND COUNTY REGULATIONS WHERE THEY APPLY.
2. ALL WORKMANSHIP, INSPECTION AND MATERIALS SHALL CONFORM TO THE LATEST
EDITIONS OF THE WASHINGTON BUILDING CODE AND ALL OTHER REGULATIONS APPLICABLE
TO ANY PORTION OF WORK.
3. FOR PURPOSES OF THE SCOPE OF STRUCTURAL WORK SHOWN HEREIN, AECOM IS THE
ENGINEER OF RECORD (EOR).
4. THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT
INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL
MEASURES NECESSARY TO PROTECT THE STRUCTURES DURING CONSTRUCTION. SUCH
MEASURES SHALL INCLUDE BUT NOT BE LIMITED TO BRACING AND SHORING ALL
EXCAVATIONS, TEMPORARY AND EXISTING STRUCTURES, AND PARTIALLY COMPLETED
PORTIONS OF THE WORK.
5. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS
GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. THE
ENGINEER OF RECORD SHALL BE NOTIFIED WHEN ACTUAL CONDITIONS CONFLICT WITH THE
DRAWINGS.
6. ALL DIMENSIONS AND SITE CONDITIONS SHALL BE VERIFIED BEFORE STARTING WORK.
THE ENGINEER OF RECORD SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES OR
INCONSISTENCIES.
7. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER THESE GENERAL
NOTES AND TYPICAL DETAILS. NUMERICAL DIMENSIONS SHALL TAKE PRECEDENCE OVER
SCALE SHOWN ON PLANS, SECTIONS AND DETAILS.
8. PRIOR TO START OF WORK, CONTRACTOR SHALL CONDUCT NECESSARY INVESTIGATION
FOR VERIFICATION OF EXISTING UNDERGROUND UTILITIES AND STRUCTURES SHOWN ON
THE DRAWINGS AND FOR IDENTIFICATION AND LOCATING EXISTING UNDERGROUND
UTILITIES AND STRUCTURES WHICH MAY NOT BE SHOWN ON THE DRAWINGS WITHIN THE
WORK AREA. THE ENGINEER OF RECORD SHALL BE NOTIFIED OF ANY INTERFERENCE
WITHIN THE NEW WORK.
9. FOR SIZE, LOCATION AND ANCHOR BOLT REQUIREMENTS OF ALL EQUIPMENT MOUNTING
BASES REFER TO MECHANICAL, PIPING, ELECTRICAL AND/OR MANUFACTURER DRAWINGS.
EQUIPMENT VENDOR SHALL PROVIDE MOUNTING TEMPLATE SHOWING ANCHOR BOLT
LOCATION FOR EQUIPMENT FURNISHED. NOTIFY THE ENGINEER OF RECORD OF ANY
DISCREPANCY.
10.ANY EQUIVALENT MATERIALS SUBSTITUTED PER "APPROVED EQUAL" NOTE, SHALL BE
APPROVED BY THE LOCAL BUILDING DEPARTMENT AND THE ENGINEER OF RECORD BEFORE
USE.
11.CONTRACTOR SHALL FURNISH ALL MATERIALS, EQUIPMENT LABOR AND SHALL PERFORM
ALL OPERATIONS AS SPECIFIED AS NECESSARY TO COMPLETE THE PROJECT. THE
CONTRACTOR SHALL SOLELY BE RESPONSIBLE FOR THE QUALITY CONTROL OF THE
SUPPLIED MATERIALS EXCEPT FOR PROCURED ITEMS BY THE OWNER.
12.THE OWNER'S TECHNICAL REPRESENTATIVE RESERVES THE RIGHT TO MAKE
INSPECTIONS AT ANY TIME DURING EXECUTION OF THE PROJECT. SUCH INSPECTIONS DO
NOT ABSOLVE THE CONTRACTOR OF THEIR DUTY TO CONSTRUCT PER THE CONTRACT
DRAWINGS AND SCOPE OF WORK, INCLUDING GEOTECHNICAL COMPACTION
REQUIREMENTS.
13.THE CONTRACTOR SHALL CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES INCLUDING
BUT NOT LIMITED TO SHORING, TEMPORARY BRACING AND FALL PROTECTION IN
ACCORDANCE WITH ALL LOCAL STATE AND FEDERAL SAFETY AND HEALTH REGULATION
AND STANDARDS AND LAWS.
14.CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR OR
ROOF. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT OF FLOOR.
PROVIDE ADEQUATE SHORING AND/OR BRACING WHERE STRUCTURE HAS TO ATTAIN
DESIGN STRENGTH.
15.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING
UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE
CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION
WITH THE PROSECUTION OF THIS WORK.
16.ALL CONDITIONS NOT SPECIFICALLY SHOWN OR DETAILED SHALL BE OF THE SAME TYPE
AND CHARACTER AS THOSE SHOWN FOR SIMILAR CONDITIONS.
17.STRUCTURAL WORK SHALL BE COORDINATED WITH THE MECHANICAL AND ELECTRICAL
DRAWINGS FOR LOCATIONS OF ALL PIPES, CONDUITS, ETC. PRIOR TO CONSTRUCTION.
CODES AND STANDARDS
THE DESIGN, DETAILING, FABRICATION, AND ERECTION OF ALL STRUCTURES SHALL
CONFORM TO THE FOLLOWING CODES, SPECIFICATIONS, U.O.N.:
1. UNIFIED FACILITIES CRITERIA (UFC) 3-301-01 OCT 2016
2. WASHINGTON BUILDING CODE (WBC) 2015
3. AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS AND
OTHER STRUCTURES W/ SUPPLEMENT NO. 1 (ASCE 7-10).
4. INTERNATIONAL BUILDING CODE (IBC) 2015
5. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
6. ASTM STANDARDS IN BUILDING CODES, LATEST EDITION.
7. ACI 530-13 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES.
DESIGN CRITERIA
1. AHU-1 WT = 5,824 LBS
DOAS-1 WT = 3,276 LBS
2. WIND PARAMETERS
RISK CATEGORY = II
EXPOSURE = D
BASIC WIND SPEED = 110 MPH
3. SNOW PARAMETERS
Is = 1.0
GROUND SNOW = 42 PSF
4. SEISMIC DESIGN PARAMETERS
RISK CATEGORY = II
Ie = 1.0 SS = 0.32 g S1 = 0.12 g SDS = 0.331 g SD1 = 0.18 g
SITE CLASS: D
SDC: C
GEOTECHNICAL REPORT AND SOILS
1. SOIL DESIGN PARAMETERS:
CLASS 5 SOIL ASSUMED PER IBC TABLE 1806.2 IN THE ABSENCE OF GEOTHECHNICAL REPORT.
ALLOWABLE VERTICAL BEARING PRESSURE = 1500 PSF
ALLOWABLE LATERAL BEARING PRESSURE = 100 PSF/FT
ALLOWABLE LATERAL SLIDING RESISTANCE = 130 PSF
COHESION (IN NO CASE SHALL THE LATERAL SLIDING RESISTANCE EXCEED ONE-HALF THE
DEAD LOAD PER IBC 1806.3.2)
FROST DEPTH = 64"
2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUPPORTS REQUIRED FOR EXCAVATION.
CONCRETE
1. ALL CONCRETE CONSTRUCTION WORK SHALL CONFORM TO AMERICAN CONCRETE INSTITUTE
SPECIFICATION ACI-318.
2. ALL STRUCTURAL CONCRETE PLACED SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF
4,500 PSI, WHEN TESTED AT 28 DAYS. LOADS SHALL NOT BE PLACED ON NEW CONCRETE UNTIL A
MINIMUM OF 28 DAYS HAS PASSED FROM TIME OF CONCRETE PLACEMENT.
3. AT CONTRACTOR'S OPTION, STRUCTURAL CONCRETE WITH A MINIMUM COMPRESSIVE
STRENGTH OF 5,000 PSI, WHEN TESTED AT 28 DAYS, MAY BE USED TO REDUCE THE TIME PERIOD
BEFORE LOAD CAN BE PLACED ON THE CONCRETE TO A MINIMUM OF 14 DAYS AFTER TIME OF
CONCRETE PLACEMENT. IF THIS CONTRACTOR'S OPTION IS IMPLEMENTED, THE NUMBER OF
CONCRETE TEST SAMPLES INDICATED IN CONCRETE NOTE #23 SHALL BE DOUBLED, AND HALF OF THE COLLECTED TEST SAMPLES SHALL BE TESTED AT 14 DAYS AFTER CONCRETE PLACEMENT TO VERIFY THAT THE 14 DAY CONCRETE COMPRESSIVE STRENGTH IS AT LEAST 3000 PSI PRIOR TO
PLACING ANY LOAD ON THE CONCRETE.
4. MIXES SHALL BE SO DESIGNED THAT AVERAGE STRENGTH DEVELOPED IN SAMPLES MADE,
CURED AND TESTED UNDER THE PROVISIONS OF THIS SPECIFICATION WILL BE AT LEAST 15
PERCENT GREATER THAN STRENGTH SPECIFIED ABOVE.
5. CONCRETE MATERIAL SPECIFICATIONS:
CEMENT (LOW ALKALI) ASTM C-150, TYPE II
COARSE AGGREGATE (3/4" MAXIMUM) ASTM C-33
FINE AGGREGATE (CONCRETE SAND) ASTM C-33
6. READY MIX CONCRETE MAY BE USED IF IT MEETS ABOVE CONCRETE SPECIFICATIONS AND
SHALL CONFORM TO ASTM C-94. WATER SHALL BE CLEAN AND CHEMICAL FREE. DISCHARGE LIMIT
SHALL NOT EXCEED 90 MINUTES FROM THE TIME THAT CONCRETE IS BATCHED.
7. SUBMIT CONCRETE MIX DESIGNS TO EOR FOR ACCEPTANCE PRIOR TO USE.
8. THE MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE AS FOLLOWS:
EXPOSED TO EARTH, UNFORMED-----------3"
EXPOSED TO EARTH OR WEATHER, FORMED----2"
ALL OTHER CONCRETE WORK-------------2"
9. EXISTING PAVING IN THE AREA OF WORK SHALL BE SAWCUT AT THE EDGES OF THE REMOVAL
AREA TO PROVIDE A CLEAN EDGE AT THE BOUNDARY OF DEMOLITION. NEW WORK SHALL MEET
AND MATCH EXISTING GRADES ALONG THE CONSTRUCTION BOUNDARY.
10.ALL CONSTRUCTION THAT WILL JOIN EXISTING STRUCTURES SHALL DO SO AT FLAT CLEAN
SURFACES EITHER EXISTING OR SAWCUT. THE CONCRETE SURFACE OF THE JOINT SHALL BE
ROUGHENED TO APPROXIMATELY 1/4" AMPLITUDE BY MECHANICAL MEANS AND SHALL BE FREE OF
DIRT, GREASE, OIL AND LOOSE MATERIAL THAT MAY EFFECT BOND. PRIOR TO PLACEMENT OF
NEW CONCRETE A COAT OF CONCRETE BONDING AGENT SHALL BE APPLIED TO ALL SURFACES
THAT WILL BE JOINED.
11.ALL FORMS SHALL BE CONSTRUCTED TO MAINTAIN THEIR REQUIRED POSITION AND SHAPE
DURING AND AFTER THE PLACING OF CONCRETE AND BE SUFFICIENTLY TIGHT TO PREVENT THE
LEAKAGE OF CONCRETE.
12.PRIOR TO PLACING CONCRETE, ALL REINFORCEMENT STEEL, ANCHOR BOLTS, DOWELS,
EMBEDDED STRUCTURAL STEEL SHAPES, BARS, PLATES OR OTHER EMBEDDED ITEMS SHALL BE
WELL SECURED IN THEIR REQUIRED POSITIONS.
13.SLEEVES SHALL BE PROVIDED FOR ALL PIPING, PLUMBING AND ELECTRICAL OPENINGS BEFORE
PLACING CONCRETE.
14.ALL EXPOSED CONCRETE EDGES SHALL BE PROVIDED WITH A 3/4" CHAMFER.
15.GROUT SHALL BE NON-SHRINK CEMENTITIOUS GROUT MEETING ASTM C-1107 GRADE C
REQUIREMENT WITH A MIN. DESIGN COMPRESSIVE STRENGTH EQUAL TO 5000 PSI. CONCRETE
SURFACE TO RECEIVE CEMENTITIOUS GROUT SHALL BE ROUGHENED TO APPROXIMATELY 1/4"
AMPLITUDE BY MECHANICAL MEANS & SHALL BE FREE OF DIRT, GREASE, OIL, AND LOOSE
MATERIAL THAT MAY AFFECT BOND.
16.NONSHRINK GROUT SHALL BE PROVIDED UNDER ALL COLUMN BASE PLATES AND OTHER
LOCATIONS SHOWN ON DRAWINGS. SUFFICIENT WATER SHALL BE ADDED TO PRODUCE A
CONSISTENCY FOR POURING WITHOUT SEGREGATION OF GROUT CONSTITUENTS.
17.ALL FLAT WORK AND PAVING SHALL HAVE A BROOM FINISH.
18.PROPOSED CONSTRUCTION JOINTS, BY CONTRACTOR, SHALL BE SUBMITTED TO THE
ENGINEER FOR REVIEW AND APPROVAL, PRIOR TO INCLUSION IN THE WORK.
19.FORMED SURFACES, EXPOSED TO VIEW, SHALL BE SMOOTH FORM FINISH AS DESCRIBED IN ACI
301. ROUGH FORM FINISH IS ACCEPTABLE ELSEWHERE.
20.PREMOLDED EXPANSION JOINT FILLER SHALL COMPLY TO ASTM 1751. JOINT SEALANT SHALL BE
1/4" DEEP AND OF A SILICON CHEMICAL RESISTANT TYPE. PROVIDE SEALANT FILL AT
CONSTRUCTION JOINT (CJ). SAWCUT 1/2" EXPANSION JOINTS (EJ) SHALL BE FILLED WITH
PREMOLDED JOINT FILLER AND A 1/4" DEEP SEALANT CAP WHERE INDICATED.
21.ALL STRUCTURAL CONCRETE MUST BE TESTED TO DETERMINE THE AVERAGE COMPRESSIVE
STRENGTH OF THE CONCRETE PLACED. CONCRETE BATCH TICKETS SHALL BE COLLECTED FOR
EACH LOAD DELIVERED AND CONCRETE SAMPLE CYLINDERS COLLECTED FOR EVALUATION AND
ACCEPTANCE IN ACCORDANCE WITH ACI 318 SECTION 5.6.
22.AN INDEPENDENT TESTING AGENCY SHALL BE HIRED BY THE CONTRACTOR TO COMPLETE
CONCRETE STRENGTH EVALUATION FOR ALL CONCRETE PLACED. THE TESTING AGENCY SHALL
PROVIDE QUALIFIED FIELD TECHNICIANS RESPONSIBLE FOR THE COLLECTION OF BATCH TICKETS, TEST SAMPLES, AND LOGGING THE INFORMATION WITH THE ASSOCIATED POUR. THE AGENCY
MUST PROVIDE A REPORT ONE WEEK AFTER THE (28) DAY CONCRETE CYLINDER TEST WITH THE
RESULTS OF THE EVALUATION ACCOMPANIED BY THE LOAD BATCH TICKETS.
TABLE #1A
MINIMUM LAP SPLICE AND ANCHORAGE DIMENSION TABLE
USE THIS TABLE FOR A615 GRADE 60-UNCOATED REINFORCING IN NORMAL-WEIGHT CONCRETE
WHEN CONCRETE COVER IS LESS THAN OR EQUAL TO ONE BAR DIAMETER OR BAR SPACING IS
LESS THAN OR EQUAL TO TWO BAR DIAMETERS. IN ALL OTHER CASES USE TABLE #1B.
(4500 PSI CONCRETE)
BAR TOP BARS OTHER BARS
SIZE LAP ANCH "Ld" LAP ANCH "Ld" #3 37" 28" 28" 22" #4 49" 37" 37" 29" #5 61" 47" 47" 36" #6 73" 56" 56" 43" #7 106" 81" 81" 63" #8 121" 93" 93" 72" #9 136" 105" 105" 81" #10 153" 118" 118" 91"
TABLE #1B
MINIMUM LAP SPLICE AND ANCHORAGE DIMENSION TABLE
USE THIS TABLE FOR A615 GRADE 60-UNCOATED REINFORCING WHEN CONCRETE COVER IS
GREATER THAN ONE BAR DIAMETER AND BAR SPACING IS GREATER THAN TWO BAR DIAMETERS.
(4500 PSI CONCRETE)
BAR TOP BARS OTHER BARS
SIZE LAP ANCH "Ld" LAP ANCH "Ld" HOOKED ANCH "Ldh" #3 25" 19" 19" 15" 8" #4 33" 25" 25" 19" 10" #5 41" 31" 31" 24" 12" #6 49" 73" 73" 29" 15" #7 71" 54" 54" 42" 17" #8 81" 62" 62" 48" 19" #9 91" 70" 70" 54" 22" #10 102" 79" 79" 61" 24"
NOTES FOR TABLES #1A AND #1B:
A. WHEN LAPPING TWO DIFFERENT SIZE BARS, USE THE LAP DIMENSION OF THE SMALLER BAR OR
THE ANCHORAGE DIMENSION OF THE LARGER BAR. USE WHICHEVER DIMENSION IS LARGER.
B. TOP BARS SHALL BE DEFINED AS BEAM AND SLAB HORIZONTAL REINFORCEMENT SO PLACED
THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE TOP
REINFORCEMENT. HORIZONTAL REINFORCING IN WALLS SHALL BE CONSIDERED TOP BARS.
REINFORCING STEEL
1. ALL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO AMERICAN CONCRETE
INSTITUTE - MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCING CONCRETE
STRUCTURES (ACI-315).
2. REINFORCING STEEL MATERIAL SPECIFICATIONS:
GRADE 60
3. ALL REINFORCING BARS SHALL BE BILLET STEEL DEFORMED BARS. ALL BENDS SHALL BE MADE
COLD.
4. ALL REINFORCING BENDS, HOOKS, OFFSETS, SPLICES AND OTHER FABRICATION DETAILS
SHALL CONFORM TO ACI MANUAL OF STANDARD PRACTICE. STIRRUPS AND TIES SHALL BE
DETAILED AS REQUIRED FOR FLEXURAL MEMBERS DESIGNED TO RESIST FORCES DUE TO HIGH
SEISMIC INFLUENCE WITH A MINIMUM 135 DEGREE BENDS AND REQUIRED HOOK EXTENSIONS.
5. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND
SPACING AS THE VERTICAL REINFORCING, UNLESS NOTED OTHERWISE.
6. PRIOR TO PLACING CONCRETE, ALL REINFORCING BARS, ANCHOR BOLTS, HOLD DOWNS
DOWELS, EMBEDDED STRUCTURAL STEEL SHAPES, BARS, PLATES OR OTHER EMBEDDED ITEMS
SHALL BE WELL SECURED IN POSITION AND INSPECTED BY THE SPECIAL INSPECTOR.
7. REINFORCING STEEL FURNISHED AND INSTALLED SHALL BE FREE OF RUST, GREASE, MILL
SCALE, OR ANY MATERIAL WHICH MAY AFFECT ITS BOND WITH CONCRETE.
STRUCTURAL STEEL
1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC "SPECIFICATIONS FOR DESIGN,
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS," 14TH EDITION (AISC 360-10).
2. ALL STEEL SHALL BE FABRICATED TO FIT TOGETHER PLUMB AND TRUE IN THE FIELD WITHOUT
ALTERATION.
3. MATERIALS
A. STEEL PLATES, ANGLES AND CHANNELS: ASTM A36, (Fy=36 KSI)
B. THREADED ROD: ASTM A307, (Fy=36 KSI)
C. STEEL TUBING: ASTM A500/A500M GRADE B
4. ALL STEEL SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH
ASTM A123 OR F2329 (G-90) U.O.N.
WELDING
1. ALL TESTING AND WELDING OF STRUCTURAL STEEL AND ALL CERTIFICATION OF WELDERS
SHALL BE PER AWS D1.1. REFER TO SPECIAL INSPECTION NOTES FOR ADDITIONAL WELDING
REQUIREMENTS.
2. ALL WELDING SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE AMERICAN WELDING
SOCIETY CODE AWS-D1.1, LATEST EDITION.
3. ALL WELDING SHALL BE DONE BY CERTIFIED WELDERS HOLDING CURRENT VALID AWS
CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE TYPE OF WELD CALLED FOR.
4. ALL WELDING SHALL BE DONE BY THE SHIELDED ARC PROCESS USING E70XX ELECTRODES
AND AWS APPROVED PROCEDURES.
MASONRY CONSTRUCTION
1. MASONRY WORK SHALL CONFORM TO THE 2013 EDITIONS OF ACI 530 AND 530.1.
2. MASONRY SHALL HAVE THE FOLLOWING MINIMUM COMPRESSIVE STRENGTHS (f'm): 2000 PSI
FOR CONCRETE MASONRY. MASONRY SHALL BE CONSTRUCTED IN RUNNING BOND AND ALL CELLS
FULLY GROUTED UON.
3. CONCRETE MASONRY UNITS (CMU) SHALL BE NORMAL WEIGHT, TYPE N-I WITH A COMPRESSIVE STRENGTH OF 2800 PSI PER ASTM C90. SIZE OF CMU SHALL BE 8" NOMINAL HEIGHT, 16" NOMINAL
LENGTH, AND WIDTH AS INDICATED IN DRAWINGS.
4. MORTAR SHALL BE TYPE "M" CONFORMING TO ACI 530 AND ACI 530.1 WITH A COMPRESSIVE
STRENGTH OF MIN 2500 PSI PER ASTM C476.
5. MORTAR JOINT SHALL BE STRAIGHT, CLEAN AND UNIFORM IN THICKNESS, AND SHALL BE
TOOLED AS SHOWN ON THE PLANS. (FLUSH JOINTS IF NO SPECIAL TREATMENT SPECIFIED). UON OR DETAILED ON THE PLANS, HORIZONTAL AND VERTICAL MORTAR JOINT SHALL BE 3/8" THICK
WITH FULL MORTAR COVERAGE ON FACE SHELL.
6. HORIZONTAL REINFORCEMENT SHALL BE PLACED IN CONTINUOUS MASONRY COURSES
CONSISTING OF BOND BEAM OR TROUGH BLOCK UNITS AND GROUTED IN PLACE.
MASONRY TABLE #1
MASONRY REINFORCING LAP SPLICE AND ANCHOR "Ld" TABLE FOR 8"
CMU BAR SIZE WALL CENTER REINFORCING LINTEL FACE REINFORCING
#4 13" 30" #5 20" 45" #6 37" 54" #7 52" 63" #8 72" 72"
NOTES:
A. WHEN LAPPING TWO DIFFERENT SIZE BARS, USE THE LAP LENGTH OF THE LARGER BAR.
7. VERTICAL BARS IN WALL ARE TO BE PLACED IN CENTER OF WALL UNLESS OTHERWISE SHOWN.
VERTICAL BARS ARE TO BE TIED OR OTHERWISE FIXED IN POSITION AT INTERVALS OF NOT MORE
THAN 200 BAR DIA. AND AT THE TOP AND BOTTOM.
8. ALL UNITS SHALL BE LAID WITH FULL MORTAR COVERAGE ON HEAD, BED (FACE SHELLS), WEBS
AND COLLAR JOINTS, UNLESS NOTED OTHERWISE.
9. PROVIDE LINTELS OVER ALL OPENINGS IN MASONRY WALLS. REFER TO THE ARCHITECTURAL
AND MECHANICAL DRAWINGS FOR LOCATION, NUMBER AND SIZES OF OPENINGS.
10.PROVIDE A MINIMUM OF ONE BAR DIAMETER OF GROUT BETWEEN REINF. AND MASONRY UNITS, AND A MINIMUM OF 1" GROUT AROUND ALL BOLTS EMBEDED IN MASONRY.
MASONRY CONSTRUCTION (CONT'D)
11.GROUT SHALL HAVE MIN. COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS AND A SLUMP
BETWEEN 8" AND 11".
12.ALL GROUT SHALL BE CONSOLIDATED WITH A MECHANICAL VIBRATOR, MIN 4000 RPM, 3/4" MAX.
HEAD. PROVIDE INSPECTION AND CLEAN OUT HOLES AT THE BASE OF THE GROUTED CELLS FOR
ALL LIFTS GREATER THAN 5 FEET.
13.GROUT FOR FILLING MASONRY CAVITIES TO BE COARSE GROUT UON, MAXIMUM COARSE
AGGREGATE SIZE IS 3/8 INCH.
14.ALL MASONRY SHALL BE CONSTRUCTED WITH SINGLE OPENED END MASONRY UNITS.
15.WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL CONSTRUCTION
JOINTS SHALL BE FORMED BY STOPPING THE GROUT POUR 1/4" BELOW THE TOP UPPERMOST
UNIT.
16.RESTRICTED BAR ANCHORAGE: IN CASES WHERE REINFORCING BARS CANNOT BE EXTENDED
AS FAR AS REQUIRED, THE BARS SHALL EXTEND AS FAR AS POSSIBLE AND END IN STANDARD
HOOK.
17.REINFORCING BAR POSITIONERS: COMMERCIAL, NON-METALLIC POSITIONERS THAT PREVENT
DISPLACEMENT OF REINFORCING BARS DURING CONSTRUCTION. INSTALL AT INTERVALS NOT
EXCEEDING 8 FEET.
18.IF BOND BEAMS OF INTERSECTING WALLS ARE SHOWN ON THE DRAWINGS TO MEET AT
DIFFERENT ELEVATIONS, EXTEND REINFORCING OF BOTH BOND BEAMS AROUND INTERSECTING
CORNER NOT LESS THAN 4 FEET IN EACH DIRECTION. LINTEL BLOCKS SHALL NOT BE USED AS
BOND BEAM BLOCKS EXCEPT AT OPENINGS WHERE BOND BEAMS AND LINTELS COINCIDE.
19.GROUT POURS SHALL NOT EXCEED 5 FEET IN HEIGHT UNLESS CLEANOUTS ARE PROVIDED IN THE BOTTOM COURSE OF THE CELL(S) TO BE GROUTED AND WRITTEN PERMISSION IS OBTAINED
FOR HIGH LIFT GROUTING.
20.VERTICAL HEAD JOINTS SHALL BE BUTTERED WELL FOR A THICKNESS EQUAL TO THE FACE
SHELL OF THE BLOCK AND THESE JOINTS SHALL BE SHOVED TIGHTLY SO THAT THE MORTAR
BONDS WELL TO BOTH BLOCKS. IF IT IS NECESSARY TO MOVE A BLOCK SO AS TO OPEN A JOINT, THE BLOCK SHALL BE REMOVED FROM THE WALL, CLEANED, AND SET IN FRESH MORTAR.
21.OVER HANGING AND MORTAR DROPPINGS AND ALL DEBRIS SHALL BE REMOVED FROM ALL
CELLS TO RECEIVE GROUT. FAILURE TO REMOVE DEBRIS SHALL BE CAUSE FOR REJECTION OF
WALL AND ALL REPAIR OR REWORK NECESSARY SHALL BE ENTIRELY AT THE CONTRACTOR'S
EXPENSE.
22.AGGREGATE SHALL CONFORM TO: ASTM C404 FOR GROUT WITH GRADING PER ASTM 0448, NO.
10. ASTM 144 FOR MASONRY MORTAR.
23.ELECTRIC CONDUIT BOXES AND/OR OTHER OBSTRUCTIONS ARE NOT PERMITTED IN CELLS
CONTAINING REINFORCING, UNLESS APPROVED BY THE ENGINEER.
24.ANCHOR BOLTS MUST BE SET WITH TEMPLATES AND HELD IN PLACE PRIOR TO GROUTING.
STEEL JOIST
1. STEEL JOISTS SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITION OF THE STEEL JOIST INSTITUTE (SJI) STANDARD SPECIFICATIONS, LOAD TABLES AND WEIGHT TABLES FOR STEEL
JOISTS AND JOIST GIRDERS.
2. THE STEEL JOIST MANUFACTURER SHALL BE A MEMBER OF THE STEEL JOIST INSTITUTE.
3. VERIFY THE EXACT SIZE AND LOCATION OF ALL OPENINGS PRIOR TO FABRICATION OF JOISTS.
4. ALL HANGERS TO SUPPORT MECHANICAL EQUIPMENT, ETC. SHALL BE SUPPORTED BY THE
BOTTOM CHORD OF JOISTS AND SHALL BE LOCATED AT THE PANEL POINTS. ALL HANGERS SHALL
BE LOCATED AT THE CENTERLINE OF THE BOTTOM CHORD MEMBER.
5. JOISTS, BRIDGING, AND X-BRACING DESIGN AND INSTALLATION DETAILS SHALL BE PROVIDED
BY THE STEEL JOIST MANUFACTURER IN ACCORDANCE WITH SJI STANDARDS.
6. JOIST BRIDGING SHALL BE FURNISHED AND INSTALLED TO MEET THE DESIGN AND SPACING REQUIREMENTS OF THE SJI STANDARD SPECIFICATIONS FOR STEEL JOISTS AND JOIST GIRDERS.
ALL BRIDGING AND BRIDGING ANCHORS SHALL BE COMPLETELY INSTALLED BEFORE
CONSTRUCTION LOADS ARE PLACED ON THE JOISTS.
7. ENDS OF JOIST BRIDGING LINES SHALL BE ANCHORED TO STEEL BEAMS OR CONCRETE WALLS.
ALL BRIDGING SHALL BE WELDED TO JOISTS IN SUCH A MANNER AS NOT TO IMPAIR THE
STRUCTURAL INTEGRITY OF THE JOIST.
8. JOISTS AND ACCESSORIES SHALL HAVE ONE SHOP COAT OF PAINT MEETING THE MINIMUM
PERFORMANCE REQUIREMENTS OF THE LATEST SJI SPECIFICATIONS, UNLESS NOTED
OTHERWISE. ASPHALT PAINT IS NOT ACCEPTABLE.
9. WELD ALL STEEL JOISTS TO SUPPORTING STRUCTURAL STEEL MEMBERS AS SHOWN ON THE
DRAWINGS AND ACCORDING TO SJI AND AWS D1.1 AS A MINIMUM.
10.TOP AND BOTTOM CHORDS OF JOISTS SHALL BE CONTINUOUS WITHOUT ANY SPLICES OF
MATERIAL.
11.ALL JOISTS SHALL HAVE A MINIMUM LENGTH OF BEARING ON MASONRY OF 4".
12.JOISTS SHALL BE ERECTED STRAIGHT. SWEEPS SHALL BE A MAXIMUM OF 1" MEASURED AT THE
CENTER.
13.JOISTS SHALL BE DESIGNED FOR A MAXIMUM TOTAL LOAD DEFLECTION OF L/240.
14.ALL STEEL SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH
ASTM A123 OR ASTMF2329.
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
ADAHA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
OF CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
C
B
A
13 24
C
B
A
13 24
REGISTRATION
L a s t
P lo tt e d
F ile n a m e
Printed on Post-Consumer Recycled Content Paper
A N
S I
D
"x
P ro je c t
M a n a g e m e n t
In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
©2022 AECOM Corporation
ISSUE/REVISION
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
CLIENT
A-E
A-1 SUBMITTAL (10%)08/12/2019
A-2 SUBMITTAL (35%)02/17/2020
A-2 RESUBMITTAL (35%)04/17/2020
B-1 SUBMITTAL (65%)07/14/2020
PROJECT
FAIRCHILD AIR FORCE BASE
REPAIR HVAC B456
B-2 SUBMITTAL (95%)12/03/2020
60604048
B-3 SUBMITTAL (100%)02/11/2022
/2
/2
:5 :5
P
M
B
IM
/6
-W A
A N
G H
V A
C B
B
/6
-W A
A N
G B
S -1
.r v t
P A
P A
L D
STRUCTURAL NOTES
S-002S -0
-S T
R U
C T
U R
A L
N O
T E
S
Architectural
AECOM
999 Town & Country Rd Orange, CA 92868
HTTP://AECOM.COM
Washington Air National Guard 141st Air Refueling Wing Fairchild Air Force Base Spokane County, WA
TEL(509) 247-7003
HTTP://www.141arw.ang.af.mil/
Architectural
AECOM
401 West A Street Suite 1200 San Diego, CA 92101
HTTP://AECOM.COM
FOUNDATIONS
1. FOUNDATION SHALL BEAR ON NATURAL SOILS OR COMPACTED STRUCTURAL FILL,
AS VERIFIED BY THE SOILS ENGINEER WHO IS HIRED BY THE CONTRACTOR.
2. FILL SOILS SHOULD BE PLACED IN LOOSE HORIZONTAL LIFTS THAT DO NOT EXCEED
8 INCHES. EACH LAYER SHOULD BE SPREAD EVENLY AND THOROUGHLY MIXED
DURING SPREADING TO OBTAIN A UNIFORM MOISTURE CONTENT AND SOIL
COMPOSITION IN EACH LAYER. AFTER EACH LAYER HAS BEEN MIXED AND SPREAD, IT
SHOULD BE COMPACTED TO A RELATIVE COMPACTION INDICATED BY TEST TO BE NOT
LESS THAN 90 PERCENT IN ACCORDANCE WITH ASTM D1557.
3. PROVIDE SHEETING, BRACING AND UNDERPINNING TO PRESERVE ADJACENT
UTILITY STRUCTURES, AS REQUIRED.
4. FOUNDATIONS SHALL NOT BE POURED IN STANDING WATER.
5. ALL REQUIRED INSERTS SLEEVES, CONDUITS, EMBEDMENTS AND PENETRATIONS
MUST BE VERIFIED WITH RESPECTIVE TRADES BEFORE CASTING CONCRETE.
6. CONTRACTOR SHALL PROVIDE CONTINUOUS DRAINAGE BY MECHANICAL METHODS
TO CONTROL SURFACE AND UNDERGROUND WATER, AS REQUIRED DURING
CONSTRUCTION.
7. CONTRACTOR SHALL ENSURE THAT GROUND WATER LEVELS UNDER ADJACENT
STRUCTURES AND PROPERTIES ARE NOT LOWERED.
8. ALL FOOTINGS, CONCRETE COLUMNS AND PIERS SHALL BE CENTERED UNDER
SUPPORT MEMBERS, UNLESS NOTED OTHERWISE ON PLANS.
9. THE OWNER AND ENGINEER ASSUME NO RESPONSIBILITY FOR THE VALIDITY OF
THE SUBSURFACE CONDITIONS DESCRIBED ON THE DRAWINGS, SPECIFICATIONS,
BORING LOGS, OR TEST PITS. THESE DATA ARE INCLUDED ONLY TO ASSIST THE
CONTRACTOR DURING BIDDING AND SUBSEQUENT CONSTRUCTION AND REPRESENT
CONDITIONS ONLY OF THESE SPECIFIED LOCATIONS AT THE PARTICULAR TIME THEY
WERE MADE.
10.SLOPE EXTERIOR FINISH GRADES AWAY FROM THE FOUNDATIONS TO ENSURE
THERE SHALL BE NO PONDING AROUND THE FOUNDATIONS. FOR SOIL INFORMATION,
OVER EXCAVATION, BACK FILL, ETC. REFER TO THE SOIL INVESTIGATION REPORT.
11.THE BOTTOMS OF EXCAVATIONS SHOULD BE INSPECTED AND APPROVED BY THE
SOILS ENGINEER PRIOR TO PLACING NEW FILL SOILS.
12.FOUNDATION SOIL SHALL BE INSPECTED AND APPROVED BY THE SOILS ENGINEER
PRIOR TO ANY POURING CONCRETE.
13.THE SOILS ENGINEER SHALL SUBMIT A LETTER OF ACCEPTANCE TO THE OWNER.
14.ADDITIONAL TESTING MAY BE REQUIRED AT THE COMPLETION OF EXCAVATION. IF
NECESSARY, THE SOILS ENGINEER SHALL MAKE FINAL RECOMMENDATIONS TO THE
STRUCTURAL ENGINEER FOR FOUNDATION DESIGN.
15.THE CONTRACTOR IS RESPONSIBLE FOR ANY SHORING REQUIRED FOR
EXCAVATION AT THE EXISTING ADJACENT BUILDINGS. THE CONTRACTOR SHALL
PROVIDE AN ENGINEERED METHOD TO FOLLOW FOR THE PROTECTION OF ADJACENT
PROPERTIES AND STRUCTURES. EXCAVATION AND FILLS SHALL COMPLY WITH THE
SOILS REPORT.
CONCRETE ANCHOR NOTES
1. CAST IN PLACE ANCHORS SHALL CONFORM TO ASTM F1554, GRADE 36, HEX HEAD,
U.O.N. CAST IN PLACE ANCHORS SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE
WITH ASTM F2329. NUTS SHALL BE CARBON STEEL IN ACCORDANCE WITH ASTM A563.
2. THE EMBEDMENT LENGTH FOR ANCHORS INSTALLED SHALL BE MEASURED FROM
THE TOP OF THE CONCRETE U.O.N.
3. STAINLESS STEEL (SS) THREADED ROD SHALL CONFORM TO HILTI HAS-R 316
THREADED ROD OR EQUIVALENT.
4. ADHESIVE ANCHORS SHALL CONFORM TO HILTI HIT-HY 200 EPOXY (OR EQUIVALENT
WITH EOR APPROVAL). USE AND INSTALLATION SHALL BE IN ACCORDANCE WITH ICC
ESR-3187 U.O.N.
5. SPECIAL INSPECTION IS REQUIRED FOR ALL ANCHOR INSTALLATIONS. REFER TO
ICC ESR'S FOR SPECIAL INSPECTION REQUIREMENTS OF POST INSTALLED ANCHORS.
STATEMENT OF SPECIAL INSPECTION:
1. SPECIAL INSPECTION IS REQUIRED IN ACCORDANCE WITH THE 2015 WASHINGTON
BUILDING CODE, AS SUMMARIZED BELOW.
2. SPECIAL INSPECTIONS ARE TO BE PROVIDED BY THE CONTRACTOR UNDER THIS
CONTRACT
3. THE SPECIAL INSPECTORS MUST BE QUALIFIED TO PERFORM THE TYPES OF
INSPECTION SPECIFIED.
4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INFORM THE SPECIAL
INSPECTOR OR INSPECTING AGENCY AT LEAST ONE WORKING DAY PRIOR TO
PERFORMING ANY WORK THAT REQUIRES SPECIAL INSPECTION. ALL WORK
PERFORMED WITHOUT SPECIAL INSPECTION IS SUBJECT TO REMOVAL.
5. THE SPECIAL INSPECTOR(S) SHALL OBSERVE THE INDICATED WORK FOR
COMPLIANCE WITH THE CONTRACT DOCUMENTS AND SUBMIT RECORDS OF
INSPECTION TO THE OWNER, ENGINEER OF RECORD AND AUTHORITY HAVING
JURISDICTION.
6. SPECIAL INSPECTIONS SHALL BE PROVIDED BY A CERTIFIED OR QUALIFIED SPECIAL
INSPECTOR(S), AS DETERMINED AND TO THE SATISFACTION OF THE OWNER,
ENGINEER OF RECORD AND AUTHORITY HAVING JURISDICTION.
7. PERIODIC SPECIAL INSPECTION IS DEFINED AS THE PART-TIME OR INTERMITTENT
INSPECTION OF THE WORK BY AN APPROVED INSPECTOR WHO IS PRESENT IN THE
AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED AND AT THE
COMPLETION OF WORK. CONTINUOUS SPECIAL INSPECTION IS DEFINED AS THE FULL-
TIME INSPECTION OF THE WORK BY AN APPROVED INSPECTOR WHO IS
CONTINUOUSLY PRESENT AND MONITORING THE WORK PERFORMED. IN ALL CASES,
THE INSPECTION SHALL BE COORDINATED AND PERFORMED SO THAT WORK CAN BE
CORRECTED PRIOR TO OTHER RELATED WORK PROCEEDING AND COVERING THE
INSPECTED WORK.
8. ASSOCIATED TESTING SHALL BE PERFORMED AS INDICATED IN THE FOLLOWING
TABLES BY AN APPROVED AND ACCREDITED AGENCY AS DETERMINED AND TO THE
SATISFACTION OF THE OWNER, ENGINEER OF RECORD AND AUTHORITY HAVING
JURISDICTION.
9. REFER TO THE FOLLOWING TABLES FOR SPECIFIC INSPECTION REQUIREMENTS
AND FREQUENCIES.
ABBREVIATIONS
& AND
@ AT
A.B. ANCHOR BOLT
ACI AMERICAN CONCRETE
INSTITUTE
ADDL ADDITIONAL
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
ASCE AMERICAN SOCIETY
OF CIVIL ENGINEERS
AST ABOVEGROUND
STORAGE TANK
BTWN BETWEEN
C.I.P. CAST IN PLACE
C.J. CONSTRUCTION JOINT
C.L. (℄) CENTER LINE
CLR CLEAR
COL COLUMN
CONC CONCRETE
CONN CONNECT(ION)
CONST CONSTRUCT(ION)
CONT CONTINUOUS
CP CONTROL POINT
CY CUBIC YARD
DEG DEGREE
DIA (∅) DIAMETER
DIM DIMENSION
DWG DRAWINGS(S)
DWL DOWEL(S)
(E) EXISTING
EA EACH
E.F. EACH FACE
EFF EFFECTIVE
E.J. EXPANSION JOINT
EL ELEVATION
EMBED EMBED(ED)(MENT)
EOR ENGINEER OF RECORD
EQ EQUAL
EQUIV EQUIVALENT
E.S. EACH SIDE
ESR EVALUATION SERVICES
REPORT
ETC ETCETERA
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
FDN FOUNDATION
FF FINISHED FLOOR
FRMG FRAMING
FT FOOT(FEET)
FTG FOOTING
GA GAUGE(GAGE)
GALV GALVANIZE(D)
GR GRADE
(H) HORIZONTAL
HDG HOT DIPPED GALVANIZED
HORIZ HORIZONTAL
IBC INTERNATIONAL
BUILDING CODE
ICC INTERNATIONAL CODE
COUNCIL
INFO INFORMATION
K KIPS
KSI KIPS PER SQUARE INCH
LB POUND
MAX MAXIMUM
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
(N) NEW
No. (#) NUMBER
N.T.S. NOT TO SCALE
OC ON CENTER
O.D. OUTSIDE DIAMETER
O.H. OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OSHA OCCUPATIONAL SAFETY
AND HEALTH
ADMINISTRATION
PL (⅊) PLATE
PLF POUNDS PER LINEAR FOOT
PS PIPE SUPPORT
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
R RADIUS
REF REFERENCE
REINF REINFORCE(ING)
(MENT)
REQD REQUIRED
SCHED SCHEDULE(D)
SDC SEISMIC DESIGN CATEGORY
SIM SIMILAR
S.O.G. SLAB ON GRADE
SPEC SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SYMM SYMMETRICAL
T TOP
T&B TOP & BOTTOM
THK THICK(NESS)
T.O. TOP OF
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TRANS TRANSVERSE
TYP TYPICAL
U.O.N. UNLESS OTHERWISE
NOTED
VERT,(V)VERTICAL
VIF VERIFY IN FIELD
WBC WASHINGTON BUILDING
CODE
W/ WITH
W/C WATER / CEMENT RATIO
WT WEIGHT
TABLE 1705.6
REQUIRED VERIFICATION AND INSPECTION OF SOILS (BY GEOTECHNICAL ENGINEER)
VERIFICATION AND INSPECTION TASK CONTINUOUS PERIODIC
- X
- X
1. VERIFY MATERIALS BELOW SHALLOW
FOUNDATION ARE ADEQUATE TO ACHIEVE
THE DESIGN BEARING CAPACITY.
2. VERIFY EXCAVATIONS ARE EXTENDED TO
PROPER DEPTH AND HAVE REACHED
PROPER MATERIAL.
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC
REFERENCED STANDARD
1. INSPECTION OF REINFORCING STEEL, INCLUDING PLACEMENT.
2. INSPECTION OF ANCHORS CAST IN CONCRETE
3. INSPECTION OF ANCHORS POST-INTALLED IN HARDENED
CONCRETE MEMBERS.
4. VERIFYING USE OF REQUIRED DESIGN MIX.
5. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE
SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR
CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE
CONCRETE.
6. INSPECTION OF CONCRETE PLACEMENT FOR PROPER APPLICATION
TECHNIQUES.
7. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
8. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF
THE CONCRETE MEMBER BEING FORMED.
- X
ACI 318: CH.20, 25.2,
25.3, 26.6.1-26.6-3
IBC 1908.4
- X
ACI 318: 17.8.2
- X
ACI 318: 17.8.2.4
- X ACI 318: CH.19, 26.4.3,
26.4.4
IBC 1904.1, 1904.2,
1908.2, 1908.3
X - ASTM C172, ASTM C31
ACI 318: 26.5, 26.12
IBC 1908.10
X - ACI 318: 26.5
IBC 1908.6, 1908.7,
1908.8
- X ACI 318: 26.5.3-26.5.5
IBC 1908.9
- X ACI 318: 26.11.1.2(b)
C O
N C
R E
T E
X
X
X
X
X
X
X
X
MINIMUM TESTS
VERIFICATION OF SLUMP FLOW AND VISUAL STABILITY INDEX (VSI) AS
DELIVERED TO THE PROJECT SITE IN ACCORDANCE WITH SPECIFICATION
ARTICLE 1.5 B.1.B.3 FOR SELF-CONSOLIDATING GROUT
VERIFICATION OF F 'm IN ACCORDANCE WITH SPECIFICATION ARTICLE 1.4 B PRIOR TO
CONSTRUCTION, EXCEPT WHERE SPECIFICALLY EXEMPTED BY THIS CODE
MINIMUM INSPECTION
INSPECTION TASK
1. VERIFY COMPLIANCE WITH THE APPROVED SUBMITTALS
2. AS MASONRY CONSTRUCTION BEGINS, VERIFY THAT
THE FOLLOWING ARE IN COMPLIANCE:
a. Proportions of site-prepared mortar
b. Construction of mortar joints
c. Grade and size of prestressing tendons and anchorages
d. Location of reinforcement, connectors, and anchorages
3. PRIOR TO GROUTING, VERIFY THAT THE FOLLOWING
ARE IN COMPLIANCE:
a. Grout space
b. Grade, type, and size of reinforcement and anchor bolts.
c. Placement of reinforcement, connectors, and anchorages
d. Proportions of site-prepared grout
e. Construction of mortar joints
Sec. 6.1
Sec. 6.1
Art. 3.2 D,
3.2 F
Art. 2.4, 3.4
Art. 3.2 E, 3.4,
3.6 A
Art. 2.6 B,
2.4 G.1.b
Art. 3.3 B
Art. 2.1,
2.6 A
Art. 3.3 B
Art. 2.4 B,
2.4 H
Art. 3.4, 3.6 A
FREQUENCY (A)
CONTINUOUS
REFERENCE FOR CRITERIA
TMS 402/
ACI 530/
ASCE 5
Art. 1.5
MASONRY CONSTRUCTION
REFERENCE: IBC SECTION 1705.4 SPECIAL INSPECTIONS AND TESTING OF MASONRY
CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE QUALITY ASSURANCE
PROGRAM REQUIREMENTS OF TMS 402/ACI 530/ASCE 5 AND TMS 602/ACI 530.1/ASCE6-LEVEL B QA
PERIODIC
4. VERIFY DURING CONSTRUCTION:
a. Size and location of structural elements
b. Type, size, and location of anchors, including other details of anchorage of masonry to structural members, frames, or other construction
c. Preparation, construction, and protection of masonry during cold weather (temperature below 40°F (4.4°C)) or hot weather (temperature above 90°F (32.2°C))
d. Application and measurement of prestressing force
e. Placement of grout is in compliance
5. OBSERVE PREPARATION OF GROUT SPECIMENS,
MORTAR SPECIMENS, AND/OR PRISMS
X
X
X
X
X
Art. 3.3 F
Sec. 6.1.4.3, 6.2.1
Art. 1.8 C,
1.8 D
Art. 3.6 B
Art. 3.5, 3.6 C
Art. 1.4 B.2.a.3,
1.4 B.2.b.3,
1.4 B.2.c.3,
1.4 B.3, 1.4 B.4
(a) Frequency refers to the frequency of inspection, which may be continuous during the task listed or periodically during the listed task, as defined in the table.
X
CONTINUOUS PERIODIC REFERENCED STANDARD
1. INSTALLATION OF OPEN-WEB JOISTS AND JOIST GIRDERS
a. END CONNECTIONS-WELDING OR BOLTED
b. BRIDGING-HORIZONTAL OR DIAGONAL
1. STANDARD BRIDGING.
2. BRIDGING THAT DIFFERS FROM THE SJI SPECS
LISTED IN SECTION 2207.1
SJI SPECS LISTED IN SECTION 2207.1
TYP
TABLE 1705.2.3
REQUIRED VERIFICATION AND INSPECTION OF OPEN WEB JOISTS AND GIRDERS
SJI SPECS LISTED IN SECTION 2207.1
x x x
TMS 602/
ACI 530.1/
ASCE 6
X
X
'H d d d 'H
'H'
HOOK LENGTHS (H) (IN INCHES)
#3
#4
#5
#6
#7
#8
#9
#10
#11 24
11-1/2
4-1/2
D 2 1D
3-1/2
4-1/2
5-1/2
4-1/2
5-1/2
7-1/2
4-1/2
1-1/2
2-1/2
11-1/4
5-1/2
4-1/2
3-3/4
2-1/4
9-
STANDARD
HOOKS
STIRRUP OR
TIE HOOK
BAR
SIZE
90°
HOOK
180°
HOOK
135°
HOOK
90°
HOOK
PRINCIPAL REINFORCING
TIE OR STIRRUP
OFFSET BEND
M A
X d d
D 1 D1 d
D
'H
6d O
R
3" M
IN
D 2
4d d T
Y P
M
IN
NOTES:
1. ALL REINFORCEMENT BENT COLD
2. FIELD BENDING NOT PERMITTED U.O.N.
90° HOOK 180°
HOOK
135° HOOK
For #6, #7, #8 BARS
AT CORNER AT INTERSECTION
" 3
3" Clr Typ
3" Clr Typ
FOOTING LONGITUDINAL
REINFORCING
BEND UP OR DOWN
STD 90 DEG, TYP
BEND UP OR DOWN
STD 90 DEG, TYP
NOTE:
LONG. REINF. WILL BE SUBSTITUTED FOR PERP. FOOTING'S
TRANS. REINF. AT CORNERS AND INTERSECTIONS AREA.
#4 @ 12" EW
INTENTIONALLY
ROUGHEN SURFACE
TO 1/4" AMPLITUDE
NOTES:
1. SEE PLAN FOR LOCATION AND DIMENSIONS.
SOG PER PLAN
1'-0" TYP
SEE PLAN FOR DIM
M
IN
T/ SLAB
T
/4
T
NOTES:
1. T = SLAB THK
2. USE "EARLY ENTRY" SAWCUT TOOLS AND TECHNIQUES TO
MAKE SAWCUT AS SOON AS POSSIBLE AFTER CONCRETE
HAS BEEN PLACED (WITHIN 12 HRS MAX). ENSURE THAT
SAWCUT DOES NOT CAUSE CONCRETE RAVELING.
SEE TYP S-001& S-002 FOR
SOILS AND FOUNDATION NOTES FOR
SUBGRADE AND COMPACTION.
1/8" SAWED JT
FILL W/ JT FILLER
CONC SOG PER PLAN
3. PROVIDE AT MAXIMUM OF 15 FEET AT EACH DIRECTION.
Vert bar, min #5*
Horiz bars with 180° std hook around vert bar4 m in m a x
2 rebars per lintel sch.on S-405
Horiz Reinf
Vert Reinf
Lintel Block
1 - #5 min
Typical wall reinf*
PLAN AT JAMB OR WALL END
LINTEL AND TOP OF WALL
Top of wall
Single Mat
Single Mat
90° hook
Typ wall Reinf
Lintel Reinf
90° Hook
2-#5 MIN
7 5/8" @ 8"
CMU
Typical bond beam unit
7 5/8" @ 8" CMU
Typical standard unit
180° hook
* PROVIDE HORIZ BARS WITH 180°
STD HOOK AROUND VERT BAR AT
SHEAR WALLS.
/8
1 1/4" face shell
/8
1 1/4" face shell
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
ADAHA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
OF CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
C
B
A
13 24
C
B
A
13 24
REGISTRATION
L a s t
P lo tt e d
F ile n a m e
Printed on Post-Consumer Recycled Content Paper
A N
S I
D
"x
P ro je c t
M a n a g e m e n t
In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
©2022 AECOM Corporation
ISSUE/REVISION
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
CLIENT
A-E
A-1 SUBMITTAL (10%)08/12/2019
A-2 SUBMITTAL (35%)02/17/2020
A-2 RESUBMITTAL (35%)04/17/2020
B-1 SUBMITTAL (65%)07/14/2020
PROJECT
FAIRCHILD AIR FORCE BASE
REPAIR HVAC B456
B-2 SUBMITTAL (95%)12/03/2020
60604048
B-3 SUBMITTAL (100%)02/11/2022
/2
/2
:5 :0
P
M
B
IM
/6
-W A
A N
G H
V A
C B
B
/6
-W A
A N
G B
S -1
.r v t
P A
P A
L D
TYPICAL DETAILS
S-003S -0
-T Y
P
IC
A L D
E T
A
IL
S
Architectural
AECOM
999 Town & Country Rd Orange, CA 92868
HTTP://AECOM.COM
Washington Air National Guard 141st Air Refueling Wing Fairchild Air Force Base Spokane County, WA
TEL(509) 247-7003
HTTP://www.141arw.ang.af.mil/
Architectural
AECOM
401 West A Street Suite 1200 San Diego, CA 92101
HTTP://AECOM.COM
NTS
1 BAR BENDS & HOOKS IN CONCRETE
NTS
2 TYPICAL FOOTING INTERSECTION
NTS
3 TYPICAL HOUSEKEEPING CONCRETE PAD
NTS
4 SLAB ON GRADE CONTROL JOINT
Scale: 1" = 1'-0"
6 HORIZ REINF @ END/CORNER OF CMU WALL
NTS
7 CMU LINTEL & JAMB REINFORCEMENT
NTS
9 TYPICAL CMU WALL REINF
SINGLE CURTAIN
CORNER INTERSECTION
#5 (V) UNO
ALTERNATE
BENDS
2'-0" MIN
40 DIA
2'-0" MIN
40 DIA
FLOOR LINE
O P E N
40d OR 2'-0" MIN, TYP.
ANCHOR Ld FOR
LINTEL PER S-001
MASONTRY TABLE #1
O P E N
L A
P C
O N
C L d h
NOTES:
PROVIDE ONE-HALF OF
INTERRUPTED VERTICAL AND
HORIZONTAL STEEL (1-#5 MIN) EA.
SIDE OF OPENING
WHERE WIDTH OF OPENING
EXCEEDS 2X WALL THICKNESS
JAMB BARS SHALL EXTEND FULL HT
OF WALL.
USE STD. 90° HOOKS WHERE 40d
EMBEDMENT IS NOT POSSIBLE
ADDITIONAL 2-#4 HORIZ,
TYP
ADDITIONAL 1 - #5 (V) MIN. (2- (V) BARS TOTAL)
Floor or Roof
USE BOND BEAM
BLOCK AT BOTTOM OF
OPENING
ADDITIONAL 2-#4 HORIZ,
TYP.
HORIZ. WALL REINF.
ADDITIONAL 1 -
#5 (V) MIN. (2- (V) BARS TOTAL)
DOWELS TO MATCH JAMB
REINF.
S-001 MASONRY
TABLE#1
WF-1 REINF. PER
FOOTING SCHEDULE
FOOTING DOWELS TO MATCH VERT
REINF IN WALL, ALT HOOKS VERT REINF
8" CMU WALL PER PLAN
HORIZ REINF PER PLAN
1'-4"
3" CLR
LAP PER S-001
MASONRY TABLE#1
WIDTH PER PLAN
CL WALL AND FOOTING
FINISH GRADE
F.F. ELEV = 0'-0" TYP
T.O.F. ELEV = -4'-0" TYP
EXPANSION JOINT
STD 90 DEG
HOOK, TYP
WF-2 REINF. PER
FOOTING SCHEDULE
FOOTING DOWELS
TO MATCH VERT
REINF IN WALL
SOG & REINF
PER PLAN
FINISHED FLOOR
EXPANSION JOINT
FINISH GRADE
VERT REINF
8" CMU WALL PER PLAN
HORIZ REINF PER PLAN
6"
1'-4"
3" CLR
L A
P P
E R
S -0
M
A S
O N
R Y
T A
B L E
7'-6"
CL WALL
F.F. ELEV = 0'-0" TYP
T.O.F. ELEV = -4'-0" TYP
STD 90 DEG
HOOK, TYP
JOIST PER PLAN
WIRE MESH PER ARCH
3 1/2"
1/2"X5"X8" LONG
EMBED PL w/ (2) 1/2" HEADED STUD w/ 5"
SPACING & 5" EFF.
EMBED.
JOIST CONN
TO EMBED
PLATE PER
JOIST MFR
CMU WALL
PER PLAN
(2)#5 CONT. @
BOND BEAM CONT.
THRU CONTROL JOINT
CL WALL
T.O.W. ELEV PER ARCH
#5 @ 16" LAP PER
TABLE #1 S-001
6"x12" POCKET IN CMU
WALL FILL WITH GROUT
JOIST BEARING ELEV PER ARCH
EXPANSION/ISOLATION JOINT AT
SLAB PERIMETER SLAB AT EXTERIOR EDGE CONSTRUCTION JOINT
CONC SLAB AND
REINF PER PLAN
BACK UP MATERIAL
FACE OF WALL,
COLUMN, PEDESTAL OR
SIMILAR
3/8" THK
PREMOLDED JOINT FILLER
CONC GRADE
SLAB AND REINF
(2) #4 CONT
FINISH GRADE
1/8" RADIUS
TOOLED EDGE
2" THICK RIGID INSULATION
4" CUSHION FILL OF
CLEAN GRAVEL
1-1/2" DEEP CONT KEY
WAY AT MID-DEPTH
#3X1'-6" INSTALL PARALLEL TO
EACH OTHER AND IN HORIZ
PLANE, SUPPORT DOWELS AS
REQ'D
#3 CONT EACH SIDE OF
CONSTRUCTION JOINT
2" THICK RIGID INSULATION
4" CUSHION FILL OF
CLEAN GRAVEL
CONC GRADE SLAB AND REINF
M
IN
8"
2" THICK RIGID INSULATION
4" CUSHION FILL
OF CLEAN GRAVEL
3/8" UNO
3/8" SQUARE JOINT SEALANT
W/ BOND BREAKER BETWEEN
BACK UP MATERIAL AND
JOINT SEALANT
NOTES:
WHEN THE BID OPTION CMU WALL IS NOT
CONSTRUCTED, THE SOILS SHALL BE TESTED TO
VERIFY IF IT IS SUSCEPTIBLE TO FROST. IT IS THE
CONTRACTOR OPTION TO ADDRESS THE FROST DEPTH
CONSIDERATION BY GEOTECHNICAL INVESTIGATION OR
THICKENED EDGE TO MEET THE FROST DEPTH
REQUIREMENT.
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
ADAHA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
OF CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
C
B
A
13 24
C
B
A
13 24
REGISTRATION
L a s t
P lo tt e d
F ile n a m e
Printed on Post-Consumer Recycled Content Paper
A N
S I
D
"x
P ro je c t
M a n a g e m e n t
In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
©2022 AECOM Corporation
ISSUE/REVISION
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
CLIENT
A-E
A-1 SUBMITTAL (10%)08/12/2019
A-2 SUBMITTAL (35%)02/17/2020
A-2 RESUBMITTAL (35%)04/17/2020
B-1 SUBMITTAL (65%)07/14/2020
PROJECT
FAIRCHILD AIR FORCE BASE
REPAIR HVAC B456
B-2 SUBMITTAL (95%)12/03/2020
60604048
B-3 SUBMITTAL (100%)02/11/2022
/2
/2
:5 :0
P
M
B
IM
/6
-W A
A N
G H
V A
C B
B
/6
-W A
A N
G B
S -1
.r v t
P A
P A
L D
TYPICAL DETAILS
S-004S -0
-T Y
P
IC
A L D
E T
A
IL
S
Architectural
AECOM
999 Town & Country Rd Orange, CA 92868
HTTP://AECOM.COM
Washington Air National Guard 141st Air Refueling Wing Fairchild Air Force Base Spokane County, WA
TEL(509) 247-7003
HTTP://www.141arw.ang.af.mil/
Architectural
AECOM
401 West A Street Suite 1200 San Diego, CA 92101
HTTP://AECOM.COM
NTS
1 CMU WALL INTERSECTIONS
NTS
2 TYPICAL REINF @ CMU OPNGS
NTSS-404
3 WF-1 CMU WALL FOOTING DETAILS
NTSS-404
4 WF-2 CMU WALL FOOTING DETAILS
NTSS-405
5 CMU WALL @ STEEL JOIST
Scale: 1" = 1'-0"
6 TYPICAL SLAB ON GRADE DETAILS
S-401
1 2 3 4 5 6
A
B
C
D
70' - 0" 10' - 0" 2' - 0" 56' - 8" 56' - 8"
(E) BUILDING
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
ADAHA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
OF CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
AREA A
AREA B AREA C
C
B
A
13 24
C
B
A
13 24
REGISTRATION
L a s t
P lo tt e d
F ile n a m e
Printed on Post-Consumer Recycled Content Paper
A N
S I
D
"x
P ro je c t
M a n a g e m e n t
In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
©2022 AECOM Corporation
ISSUE/REVISION
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
CLIENT
A-E
KEYPLAN:
A-1 SUBMITTAL (10%)08/12/2019
A-2 SUBMITTAL (35%)02/17/2020
A-2 RESUBMITTAL (35%)04/17/2020
B-1 SUBMITTAL (65%)07/14/2020
PROJECT
FAIRCHILD AIR FORCE BASE
REPAIR HVAC B456
B-2 SUBMITTAL (95%)12/03/2020
60604048
B-3 SUBMITTAL (100%)02/11/2022
/2
/2
:5 :0
P
M
B
IM
/6
-W A
A N
G H
V A
C B
B
/6
-W A
A N
G B
S -1
.r v t
P A
P A
L D
STRUCTURAL FLOOR PLAN -
FIRST FLOOR
S-110S -1
-S T
R U
C T
U R
A L F
L O
O R
P L A
N
F
IR
S T
F L O
O R
Architectural
AECOM
999 Town & Country Rd Orange, CA 92868
HTTP://AECOM.COM
Washington Air National Guard 141st Air Refueling Wing Fairchild Air Force Base Spokane County, WA
TEL(509) 247-7003
HTTP://www.141arw.ang.af.mil/
Architectural
AECOM
401 West A Street Suite 1200 San Diego, CA 92101
HTTP://AECOM.COM
Scale: 1/16" = 1'-0"
1 STRUCTURAL FLOOR PLAN - FIRST FLOOR
3 4
D
(N) 6" S.O.G. W/ #5 @ 16" OC EW
@ MID HEIGHT, TYP(N) AHU UNIT PER
MECHANICAL
(E) 12" CMU WALL
TO REMAIN
(N) DOAS UNIT
PER MECHANICAL
28' - 0"
(N) DUCT PER
MECHANICAL
(N) 6'-0"x9'-10"x4"
HOUSEKEEPING PAD
W/ #4 @ 12" OC EW @
MID HEIGHT, TYP
SEE DETAIL 3/S-003
(N) 4-1/2"Ø HILTI HAS-R 304/316 SS THREADED
ROD W/ 4" EFFECTIVE EMBEDMENT, SECURE W/
HILTI HIT-RE 500 V3 PER ICC ESR-3814 AND MIN
OF 4" EDGE DISTANCE, TYP
(N) 4-5/8"Ø HILTI HAS-R 304/316
SS THREADED ROD W/ 4"
EFFECTIVE EMBEDMENT,
SECURED W/ HILTI HIT-RE 500
V3 PER ICC ESR-3814 AND MIN
OF 4" EDGE DISTANCE, TYP
(N) CHAIN LINK FENCE PER S-501
SEE ARCH FOR ADD'L DETAILS
(N) DUCT PER MECHANICAL
(N) 8'-10"x25'-2"x4"
HOUSEKEEPING PAD
W/ #4 @ 12" OC EW @
MID HEIGHT, TYP
SEE DETAIL 3/S-003
(N) H-STAND DOUBLE, 120" UPRIGHT
HEIGHT AND 36" CROSS BASE WIDTH
W/ DIRECT MOUNT BASE HDG FINISH
W/ MINIMUM OF FOUR ANCHOR BOLTS
PER EACH BASE PER DETAIL 1/S-502
(N) H-STAND DOUBLE, 120" UPRIGHT
HEIGHT AND 36" CROSS BASE WIDTH
W/ DIRECT MOUNT BASE HDG FINISH
W/ MINIMUM OF FOUR ANCHOR BOLTS
PER EACH BASE PER DETAIL 1/S-502
(N) H-STAND DOUBLE, 120" UPRIGHT
HEIGHT AND 120" CROSS BASE WIDTH
W/ DIRECT MOUNT BASE HDG FINISH
W/ MINIMUM OF FOUR ANCHOR BOLTS
PER EACH BASE PER DETAIL 1/S-502
1' - 6"1' - 0"
COORDINATE THE LOCATION OF POST
AND FOOTING WITH (E) FOOTING, VIF.
TYP
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
ADAHA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
OF CALI
A N
RAM
T
S
CUR
HS
UT
L
AR
IB
AD
A
HA
No. 6440
Exp. 9-30-23
AN
SE
P O S R
IF O
N I
G E
E R
I A
E N
D L
T E
I G
R S
R E E
S T
FO
RT
E
O F CALI
A N
RAM
T
S
CUR
AREA A
C
B
A
13 24
C
B
A
13 24
REGISTRATION
L a s t
P lo tt e d
F ile n a m e
Printed on Post-Consumer Recycled Content Paper
A N
S I
D
"x
P ro je c t
M a n a g e m e n t
In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
©2022 AECOM Corporation
ISSUE/REVISION
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
CLIENT
A-E
KEYPLAN:
A-…
This is the start of the file's text. The full file is on GovTribe.