9MD2071 - Exhibit C - Level 3 Security Requirements
91 KB Posted
- Solicitation number
- 9MD2071-3
About this file
GSA RLP No. 9MD2071 - Exhibit C
Text of this file
Security Requirements (Level III) (REV 9/28/12) Page 1 __________ & __________
LESSOR GOV’T
SECURITY REQUIREMENTS – FACILITY SECURITY LEVEL III
THESE PARAGRAPHS CONTAIN ADDITIONAL SECURITY REQUIREMENTS THAT
MAY BE INSTALLED IN THE LEASED SPACE, AND UNLESS INDICATED
OTHERWISE, ARE TO BE PRICED AS PART OF THE BUILDING SPECIFIC
AMORTIZED CAPITAL (BSAC). BECAUSE EACH BUILDING IS UNIQUE, THE
FINAL LIST OF SECURITY COUNTERMEASURES WILL BE DETERMINED DURING
THE DESIGN PHASE AND IDENTIFIED IN THE DESIGN INTENT DRAWINGS AND
CONSTRUCTION DOCUMENTS. AFTER COMPLETING THE CONSTRUCTION
DOCUMENTS, THE LESSOR SHALL SUBMIT A LIST OF THE ITEMIZED COSTS.
SUCH COSTS SHALL BE SUBJECT TO NEGOTIATION.
WHERE THEY ARE IN CONFLICT WITH ANY OTHER REQUIREMENTS OF THIS
LEASE, THE STRICTEST SHALL APPLY.
DEFINITIONS:
CRITICAL AREAS AND SYSTEMS – The areas that house systems that if damaged and/or compromised could have significant adverse consequences for the facility, operation of the facility, or mission of the agency or its occupants and visitors. These areas may also be referred to as “limited access areas,” “restricted areas,” or “exclusionary zones.” Critical areas do not necessarily have to be within Government-controlled Space (e.g., generators, air handlers, electrical feeds, utilities, telecom closets or potable water supply that may be located outside Government-controlled Space).
SENSITIVE AREAS – Sensitive areas include vaults, SCIFs, evidence rooms, war rooms, and sensitive documents areas. Sensitive areas are primarily housed within Government-controlled space.
FACILITY ENTRANCES, LOBBY, COMMON AREAS, NON-PUBLIC,
AND UTILITY AREAS
If the leased Space is greater than 50% of the space in the Building (based upon ABOA measurement), the requirements of FACILITY ENTRANCES AND LOBBY Section below shall apply to the entrance of the Building. If the leased Space is less than or equal to 50% of the space in the Building (based upon ABOA measurement), then the requirements of FACILITY ENTRANCES AND LOBBY Section below shall apply to the entrance of the leased Space.
FACILITY ENTRANCES AND LOBBY
LIMITING LOBBY QUEUING
The Lessor and the Government shall create a separate foot traffic flow pattern for employees and visitors at entrances to minimize lobby queuing caused by screening, visitor processing, and access control systems.
Security Requirements (Level III) (REV 9/28/12) Page 2 __________ & __________
PHYSICAL BOUNDARIES TO CONTROL ACCESS TO PUBLIC AND NON-PUBLIC AREAS – LEVEL
III
The Government reserves the right to use stanchions, counters, furniture, knee walls or product-equivalents, as determined by the Government, to establish physical boundaries to control access to non-public areas. The Lessor shall post directional signs as appropriate.
SCREENING REQUIREMENTS
VISITOR SIGN-IN/OUT AFTER HOURS
The Lessor shall provide a system, acceptable to the Government, that after hour visitors to the Building shall be required to sign in and sign out either electronically or in a Building register.
MAGNETOMETERS AND X-RAYS AT PUBLIC ENTRANCES
Magnetometers and X-ray machines will be installed by the Government at the public entrance. Armed security guards, provided by the Government, will direct the occupants and visitors through the screening equipment. Appropriate lobby and entrance/exit space shall be made available for this purpose. This space shall be considered part of the lease common area and not ABOA square footage. The Government requires visitors to non-public areas to display a visitor’s identification badge. If there are other non-Government tenants, the Lessor shall notify them of this requirement and assist those tenants in obtaining ID acceptable to the Government.
ACCOMMODATION OF RETAIL/MIX USE SPACE
All non-Government personnel entering from retail or public space must enter through a screening point.
COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS
PUBLIC RESTROOMS ACCESS (SHELL)
The Lessor shall provide a means to control access to public restrooms within Government controlled space that is acceptable to the Government.
SECURING CRITICAL AREAS
Areas designated as Critical Areas shall be locked using HSPD-12 compliant electronic access control equipment (see IDS requirements). The Government shall have the right to monitor and limit access to these areas. Access shall be limited to authorized personnel, as determined by the Government.
VISITOR ESCORT AND ID REQUIREMENTS
The Government shall require the Lessor to escort contractors, service personnel, and visitors to all non-public areas. The Lessor shall require visitors to non-public areas to display a visitor ID at all times.
SECURING COMMON BUILDING UTILITIES AND ACCESS TO ROOF
The Lessor shall secure utility, mechanical, electrical telecommunication rooms, and access to interior space from the roof using locks and an Intrusion Detection System (IDS).
RESTRICT CONTACT FROM PUBLIC AREAS WITH PRIMARY VERTICAL LOAD MEMBERS
The Lessor shall implement architectural or structural features, or other positive countermeasures that deny contact with exposed primary vertical load members in the public areas. A minimum standoff of at least 100 mm (4 inches) is required.
RESTRICT CONTACT FROM MAIL AREA WITH PRIMARY VERTICAL LOAD MEMBERS
The lessor shall implement architectural or structural features, or other positive countermeasures in the mail screening and receiving areas that deny contact with exposed primary vertical load members. A minimum standoff of at least 150 mm (6 inches) is required.
Security Requirements (Level III) (REV 9/28/12) Page 3 __________ & __________
INTERIOR OF SPACE
WEARING PHOTO ID IN GOVERNMENT SPACE
The Lessor and his contractors shall be required to wear a photo ID to be visible at all times when in Government- controlled Space.
SECURE EMPLOYEE ENTRANCE DOORS
The Lessor shall provide a means to secure, as determined by the Government, doors identified by Government as employee entrance doors. The Government may elect to post guards to verify ID badges via visual and physical inspection before entry to Government occupied Space.
LIMIT ON ENTRY POINTS (SHELL)
The Government may elect to limit the number of entry points to the Building or to the Government occupied Space to the fewest number practicable.
FORMAL KEY CONTROL PROGRAM (SHELL)
The Government reserves the right to implement a formal key control program. The Lessor shall have a means of allowing the electronic disabling of lost or stolen access media, if electronic media is used.
ELECTRONIC ACCESS FOR EMPLOYEES
The Lessor shall provide electronic access control for employee entry doors without a guard post (including after-hours access) in conjunction with CCTV coverage.
SITE AND EXTERIOR OF THE BUILDING
SIGNAGE
POSTING OF SIGNAGE IDENTIFYING THE SPACE AS GOVERNMENTAL (SHELL)
The Lessor shall not post sign(s) or otherwise identify the facility and parking areas as a Government, or specific Government tenant, occupied facility, including during construction, without written Government approval.
POSTING OF REGULATORY SIGNAGE (SHELL)
The Government may post or request the Lessor to post regulatory, statutory, sensitive areas, and site specific signage.
LANDSCAPING AND ENTRANCES
LANDSCAPING REQUIREMENTS (SHELL)
Lessor shall maintain landscaping (trees, bushes, hedges, land contour, etc,) around the facility.
Landscaping shall be neatly trimmed in order to minimize the opportunity for concealment of individuals and packages/containers. Landscaping shall not obstruct the views of security guards and CCTV cameras, or interfere with lighting or IDS equipment.
CRIME PREVENTION THROUGH ENVIRONMENTAL DESIGN (SHELL)
The Lessor shall separate from public access, restricted areas as designated by the Government, through the application of Crime Prevention Through Environmental Design (CPTED) principles by using trees, hedges, berms, or a combination of these or similar features, and by fences, walls, gates and other barriers, where feasible and acceptable to the Government.
HAZMAT STORAGE
If there is HAZMAT storage, Lessor shall locate it in a restricted area or storage container away from loading docks, entrances, and uncontrolled parking.
Security Requirements (Level III) (REV 9/28/12) Page 4 __________ & __________
PLACEMENT OF RECEPTACLES, CONTAINERS, AND MAILBOXES – LEVEL III
Trash receptacles, containers, mailboxes, vending machines, or other fixtures and features that could conceal packages, brief cases, or other portable containers shall be located 10 feet away from the Building.
VEHICLE BARRIERS
The Lessor shall provide vehicle barriers to protect pedestrian and vehicle access points, and Critical Areas from penetration by a 4,700 pound vehicle traveling at 35 mile per hour.
PARKING
NUMBER OF PARKING ENTRANCES
The number of parking entrances shall be limited to the minimum required for efficient operations or local code. Entrances to parking areas shall be equipped with vehicle gates to control access to authorized vehicles (employee, screened visitor and approved Government vehicle).
ILLUMINATION OF ENTRANCES, EXITS, PARKING LOTS AND GARAGES (SHELL)
Facility entrances, exits, parking lots and garages shall be illuminated to a minimum of 5 lumens, at all times.
AUTHORIZED ACCESS TO PARKING (SHELL)
Lessor shall limit parking and access to parking to authorized individuals.
VEHICLE SCREENING
The Government may elect to screen all visitor vehicles as prescribed by the Government. This screening shall include ID verification and visual inspection of the vehicle, including undercarriage. The Lessor shall provide adequate lighting in screening area to illuminate the vehicle exterior and undercarriage. CCTV coverage of the screening area shall be provided by the Lessor (see CCTV requirements).
PUBLIC ACCESS TO GOVERNMENT PARKING AREAS
Where there is Government controlled parking the area shall be controlled by limiting pedestrian access to the controlled parking areas. Pedestrian and vehicle access points to all parking areas shall be monitored by CCTV camera(s) at all times.
SECURITY SYSTEMS
CLOSED CIRCUIT TELEVISION SYSTEM (CCTV)
GOVERNMENT PROVIDED PRODUCT, INSTALLATION, AND MAINTENANCE
The Government may elect to provide and install an entry control system, with time lapse video recording, that will allow Government employees to view and communicate remotely with visitors before allowing access. This Closed Circuit Television (CCTV) system shall provide the Government with unobstructed coverage, as determined by the Government, of designated pedestrian entrances and exits. The Lessor shall permit twenty-four hour CCTV coverage and recording, provided and operated by the Government.
The Government will centrally monitor the CCTV surveillance. Government specifications are available from the Contracting Officer. The Lessor shall post necessary regulatory, statutory, and/or site specific signage, as determined by the Government.
The Lessor, at the notice to proceed stage of the procurement, shall advise the Government of the appropriate time to install the equipment during the construction of the Space and shall facilitate the installation, including access to electrical panels and other areas of the building, as necessary.
Security Requirements (Level III) (REV 9/28/12) Page 5 __________ & __________
INTRUSION DETECTION SYSTEM (IDS)
GOVERNMENT PROVIDED SCOPE AND PRODUCT, INSTALLATION, AND MAINTENANCE
The Lessor shall permit installation of a perimeter Intrusion Detection System (IDS) to be operated by the Government. The Government shall provide and install an IDS on perimeter entry and exit doors, and operable ground-floor windows. Basic Security-in-Depth IDS— include: magnetic door switch(s), alarm system keypad, passive infrared sensor(s) (PIR), an alarm panel (to designated monitoring center) and appropriate communication method i.e. telephone and/or Internet connection, glass-break detector, magnetic window switches or shock sensors.
Basic Security-in-Depth IDS shall be connected and monitored at a central station. Emergency notification lists shall be coordinated with the monitoring station to include all applicable Government and Lessor points of contact. Monitoring shall be designed to facilitate a real-time detection of an incident, and to coordinate an active response to an incident.
The Lessor, at the notice to proceed stage of the procurement, shall advise the Government of the appropriate time to install the equipment during the construction of the Space and shall facilitate the installation, including access to electrical panels and other areas of the building, as necessary.
DURESS ALARM
GOVERNMENT PROVIDED SCOPE, PRODUCT, INSTALLATION, AND MAINTENANCE
The Lessor shall permit installation of a duress alarm system to be provided and operated by the Government. The Government, in coordination with a security provider, either internal or external, as determined by the Contracting Officer, shall document and implement duress procedures for emergency situations.
The Lessor, at the notice to proceed stage of the procurement, shall advise the Government of the appropriate time to install the equipment during the construction of the Space and shall facilitate the installation, including access to electrical panels and other areas of the building, as necessary.
STRUCTURE
WINDOWS
SHATTER-RESISTANT WINDOW PROTECTION
The Lessor shall provide and install, shatter-resistant material not less than 0.18 millimeters (7 mil) thick on all exterior windows in Government-occupied Space meeting the following properties - Film composite strength and elongation rate measured at a strain rate not exceeding 50% per minute shall not be less than the following:
- Yield Strength: 12,000 psi
- Elongation at yield: 3%
- Longitudinal Tensile strength: 22,000 psi
- Traverse Tensile strength: 25,000 psi
- Longitudinal Elongation at break: 90%
- Traverse Elongation at break: 75%
THE ALTERNATIVE METHOD is for the Lessor to provide a window system that conforms to a minimum glazing performance condition of “3b” for a high protection level and a low hazard level. Window systems shall be certified as prescribed by WINGARD PE 4.3 or later to GSA performance condition “3b” (in accordance with the GSA Standard Test Method for Glazing and Window Systems Subject to Dynamic Loadings or Very Low Hazard (in accordance with ASTM F 1642, Standard Test Method for Glazing or Glazing Systems Subject to Air Blast Loading) in response to air blast load of 4 psi/28 psi-msec.
Security Requirements (Level III) (REV 9/28/12) Page 6 __________ & __________
If the Lessor chooses the Alternative Method, the Lessor shall provide a description of the shatter-resistant window system and provide certification from a licensed professional engineer that the proposed system meets the above standard. Prior to installation, this will be provided for evaluation by the Government, whose approval shall not be unreasonably withheld.
LOCK GROUND FLOOR WINDOWS (SHELL)
The Lessor shall lock all ground floor windows with L-brackets using security screws, or equivalent measure, acceptable to the Government.
SECURE NON-WINDOW OPENINGS (SHELL)
The Lessor shall secure all non-window openings, such as, mechanical vents, utility entries, and exposed plenums to prevent unauthorized entry.
PREVENT VISUAL OBSERVATION INTO "SENSITIVE AREAS"
The Lessor shall provide blinds, curtains, or other window treatments in “Sensitive Areas” that can be employed to prevent visual observation of that area that is acceptable by the Government.
BUILDING SYSTEMS
EMERGENCY GENERATOR
The Lessor shall locate emergency generators, either pre-existing or installed as part of Tenant Improvements, in a secure area, protected from unauthorized access and vehicle ramming, if outdoors.
The emergency generator and its fuel tank must be located at least 25 feet from loading docks, entrances, and parking areas.
SECURING ON-SITE PUBLICLY-ACCESSIBLE UTILITIES
The Lessor shall secure the water supply handles, control mechanisms, and service connections at on-site publicly-accessible locations with locks and anti-tamper devices acceptable to the Government.
SECURING AIR INTAKE GRILLES
The Lessor shall secure air intake grilles less than 30 feet above grade or otherwise accessible. Air intake grilles shall be secured with tamper switches connected to a central alarm monitoring station and monitored by CCTV or other security systems. As an alternative the air intake may be relocated to a position greater than 30 feet above grade.
HVAC SYSTEM FOR CHEMICAL, BIOLOGICAL AND RADIOLOGICAL (CBR) ATTACK-
SUSCEPTIBLE AREAS
The Lessor shall provide separate isolated HVAC systems in lobbies, loading docks, mail rooms and other locations as identified by a risk assessment as susceptible to CBR attack, to protect other building areas from possible contamination.
All exterior air handling units (AHUs), including the supply air for re-circulating AHUs, shall be equipped with Minimum Efficiency Reporting Value (MERV) 10 particulate filters. AHUs serving lobbies and mailroom, including the supply air stream for re-circulating AHUs, shall be equipped with Minimum Efficiency Reporting Value (MERV) 13 filters.
OPERATIONS AND ADMINISTRATION
LESSOR TO WORK WITH FACILITY SECURITY COMMITTEE (SHELL)
The Lessor shall cooperate and work with the buildings Facility Security Committee (FSC) throughout the term of the lease.
Security Requirements (Level III) (REV 9/28/12) Page 7 __________ & __________
ACCESS TO BUILDING INFORMATION (SHELL)
Building Information—including mechanical, electrical, vertical transport, fire and life safety, security system plans and schematics, computer automation systems, and emergency operations procedures— shall be strictly controlled. Such information shall be released to authorized personnel only, approved by the Government, by the development of an access list and controlled copy numbering. The Lease Contracting Officer may direct that the names and locations of Government tenants not be disclosed in any publicly accessed document or record. If that is the case, the Government may request that such information not be posted in the building directory.
Lessor shall have emergency plans and associated documents readily available in the event of an emergency.
SECURITY PLANS AND LAYOUTS – LEVEL III
The Lessor shall treat and safekeep any plans and specifications related to security measures as For Official Use Only (FOUO).
SCREENING OF MAIL AND PACKAGES – LEVEL III
Lessor shall provide space suitable for the Government to inspect and screen all mail and packages using X-ray at a loading dock, if present. If there is no loading dock, Lessor shall provide space at an existing screening location or at an alternative location in the Building acceptable to the Government. The space shall be located on an exterior wall, 25 feet or less from an exterior door, with a stand-alone air handling system. The screeners shall physically inspect items that cannot be passed through screening equipment before distribution to the Government agencies throughout the facility. This space shall be considered part of the lease common area and not ABOA square footage.
OCCUPANT EMERGENCY PLANS (SHELL)
The Lessor is required to cooperate, participate and comply with the development and implementation of the Government’s Occupant Emergency Plan (OEP) and if necessary, a supplemental Shelter-in Place (SIP) Plan. Periodically, the Government may request that the Lessor assist in reviewing and revising its OEP and SIP. The Plan, among other things, must include an annual emergency evacuation drill, emergency notification procedures of the Lessor’s building engineer or manager, building security, local emergency personnel, and Government agency personnel.
SECURITY GUARD POSTINGS
The Government may elect to post armed security guards at all screening checkpoints and at the entrances to Government-occupied Space.