Minimum and Specific Requirements
Armed Forces Career Center
Minimum Usable Square Footage: 6,381 SF
Maximum Usable Square Footage: 8,396 SF
Minimum Requirements for All Offices:
1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.
2. 24-hour lighted or secured parking within the lessor’s premises for TWENTY-THREE
(23) Government vehicles.
3. Adequate parking for Service member privately owned vehicles during working hours, as well as for office visitors.
4. 24-hour access to the leased spaces.
5. High-speed data service connection (Fiber is preferred) from the street to the building demarcation point.
Army Specific Requirements 2,833 SF Min – 3,728 SF Max:
1. Private Offices: One (1) private office of 100 SF within each individual Armed Forces
Center; see specific requirements detailed within the construction specifications.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 13 workstations.
3. Testing/Conference Room: One (1) testing room of 100 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 125 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board.
- 2 -
Navy Specific Requirements 1,269 SF Min – 1,670 SF Max:
1. Private Offices: One (1) private office of 100 SF within each individual Armed Forces
Center; see specific requirements detailed within the construction specifications.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 5 workstations.
3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board.
USMC Specific Requirements 1,1269 SF Min – 1,670 SF Max:
1. Private Offices: One (1) private office of 100 SF within each individual Armed Forces Center; see specific requirements detailed within the construction specifications.
2. Open Space for cubicles or work stations: Space lay out to include an open area within the suite for 4 work stations.
3. Testing/Conference Room: One (1) testing room of 80 SF with a glass door facing the open area for test monitoring. This testing room will NOT have a window installed.
4. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board.
Air Force Specific Requirements 580 SF min – 763 SF Max:
1. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 2 workstations.
2. Testing/Conference Room: One (1) testing room of 70 SF with a window or a glass door facing the open area for test monitoring.
3. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board.
- 3 -
Air Force Reserves Specific Requirements 428 SF min – 563 SF Max:
1. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 1 workstation.
2. Testing/Conference Room: One (1) testing room of 70 SF with a window or a glass door facing the open area for test monitoring.
3. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board.
4. Floor Plan: A floor plan has been included to provide a sample view of a typical career center layout.
Common Area Requirements:
1. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 30 SF for CCTV system and entry control system housing. This closet should be located in the common area of the multiple Service station.
2. Restrooms: A minimum of TWO (2) 100 SF, located in the common area, each restroom meeting ADA specifications built to accommodate at least two occupants at one time.
3. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications. The janitorial closet must be located in the common area.