8-08. Project Plans (7 Sheets).pdf
PDF 12 MB Posted
- Attached to
- Starling Drive Sanitary Sewer Rehabilitation
- Solicitation number
- US.203157
- Issued by
- Allegheny County, Philadelphia City, Pennsylvania
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
BWT BWT KSW
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
\\E gn yt eD riv e\
R
VE
_E gn yt e\
Sh ar ed \2
_O ld
Se rv er s\
Pi tts bu rg h\ Sh ar ed
\K en ne dy
T w p\
PA
KT
T0
AC
O
3\ C
AD
\S
EW
ER
R
EP
AI
R
P
LA
N
PA
KT
T0
).d w g
/2 2/
1:
:1
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
(412) 263-2200, FAX (412) 263-2210
105 BRAUNLICH DRIVE, SUITE 100
PITTSBURGH, PA 15237
REMINGTON
& VERNICK
ENGINEERS
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
PROFESSIONAL ENGINEER LIC. No. PE-040662-E
MICHAEL G. MEYER
DATE:
09/22/2025
PAKTT096
AS NOTED
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
AL
LE
G H
EN
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
ST
AR
LI
N
G D
R
IV
E
SA
N
IT
AR
Y
SE
W
ER
R
EH
AB
IL
IT
AT
IO
N P
R O
JE
C
T
CONSTRUCTION
DOCUMENTS
N
PA ONE - CALL SYSTEM
R
-8
-2
-1
P E
S
L
N
AC
L
YLS N
P
N
OT
V A
EB FO
AI
O
U
YE
O
CE LA L
D
STE
S
IG
Y
M I
C N
9/22/2025
SHEET INDEX
SHEET DESCRIPTION
C000 COVER SHEET
C001 GENERAL NOTES
C300 REHABILITATION PLAN
C301 REHABILITATION PLAN
C400 MANHOLE DETAIL AND REPAIR PLAN TABLES
C401 SANITARY SEWER PIPE DEFECT TABLES
C500 CONSTRUCTION DETAILS
PROJECT LOCATION MAP
STARLING DRIVE
LIST OF UTILITIES AND
CONTACT INFORMATION
PUBLIC
WORKS:
WATER:
SEWER:
ELECTRIC:
CABLE:
GAS:
TELEPHONE:
KENNEDY TOWNSHIP PUBLIC WORKS DEPARTMENT
CHRIS GUTT, FOREMAN
(412) 551-2503
DU4UESNE LIGHT COMPANY
469 HERSHEY ROAD
PITTSBURGH, PA 15235
(412) 393-2055
PHIL LONG
COMCAST CABLE COMMUNICATIONS
JOSEPH BECHTOLD
1530 CHARTIERS AVENUE
PITTSBURGH, PA 15204
(800) 266-2278
PEOPLES NATURAL GAS
625 LIBERTY AVENUE
PITTSBURGH, PA 15222
(412) 471-5100
CUSTOMER SERVICE
VERI=ON
DEBORAH BARUM
15 E. MONTGOMERY AVENUE
PITTSBURGH, PA 15212
(412) 633-3131
C000
C O
VE
R
S H
EE
T
WEST VIEW WATER AUTHORITY
ENGINEERING DEPARTMENT
2428 ROCHESTER ROAD
SEWICKLEY, PA 15143
(412) 931-3292
ROBERT HUTTON
TOWNSHIP OF KENNEDY
ALLEGHENY COUNTY, PENNSYLVANIA
KENNEDY TOWNSHIP PUBLIC WORKS DEPARTMENT
CHRIS GUTT, FOREMAN
(412) 551-2503
SANITARY SEWER REHABILITATION PROJECT
TOWNSHIP OF KENNEDY
EXISTING CONDITIONS & SURVEY NOTES
1.PROPERTY AND RIGHT-OF-WAY LINES SHOWN ON THESE PLANS ARE AS PER THE CURRENT PARCEL MAPS & TAX
ASSESSMENT RECORDS OF THE COUNTY OF MONTGOMERY, COMMONWEALTH OF PENNSYLVANIA. ADJOINER PROPERTY LINES AND RIGHT-OF-WAYS ARE SHOWN FOR INFORMATION ONLY AND HAVE NOT BEEN FIELD
VERIFIED.
2.A DESIGN REQUEST FOR UNDERGOUND UTILITY OR STRUCTURE INFORMATION HAS BEEN SUBMITTED THROUGH THE PA ONE CALL SYSTEM FOR THIS PROJECT. THE DESIGN REQUEST SERIAL NUMBER FOR THIS PROJECT IS 20221164225.
3.THIS PLAN AND SURVEY DOES NOT CERTIFY THE LOCATION, BOTH HORIZONTAL AND VERTICAL, OF ANY
UNDERGROUND UTILITY OR STRUCTURE THAT WAS NOT EXPOSED FOR DIRECT MEASUREMENT.
4.BASELINES HAVE BEEN PROVIDED ON THE PLANS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE THE
BASELINE AS SHOWN ON THE PLANS.
5.PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN THE FIELD. ANY ERRORS OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
ENGINEER IMMEDIATELY.
EROSION & SEDIMENT CONTROL (E&S) NOTES
1.THE CONTRACTOR SHALL INSTALL AND MAINTAIN ALL TEMPORARY E&S BEST MANAGEMENT PRACTICES (BMPS) DURING THE CONSTRUCTION. TEMPORARY E&S BMPS SHALL INCLUDE ANY DEPICTED ON THE PLANS AND THE
FOLLOWING:
a.STORM INLET PROTECTION. INLET FILTER BAGS SHALL BE INSTALLED IN EACH EXISTING AND PROPOSED
STORM INLET RECEIVING RUNOFF FROM THE PROJECT AREA.
b.SEDIMENT BARRIERS. COMPOST FILTER SOCK, SILT FENCE OR OTHER SUITABLE BARRIERS SHALL BE
INSTALLED ON LEVEL GRADE DOWNSTREAM FROM DISTURBED AREAS AND STOCKPILES.
c.CONCRETE WASHOUT. FOR ANY PROJECT WHERE CONCRETE WILL BE POURED ON SITE, A SUITABLE
WASHOUT FACILITY MUST BE PROVIDED.
d.PUMPED WATER FILTER BAG. A PUMPED WATER FILTER BAG SHALL BE USED TO FILTER WATER PUMPED FROM EXCAVATED AREAS (DEWATERING), SEDIMENT STORAGE AREAS OF SEDIMENT BASINS AND SEDIMENT
TRAPS.
2.E&S BMPS SHALL BE INSPECTED AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT, REGRADING, RESEEDING, REMULCHING AND RENETTING MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS FAIL TO PERFORM AS
EXPECTED, REPLACEMENT BMPS OR MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
3.UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE CONTRACTOR SHALL REMOVE ALL TEMPORARY E&S BMPS. PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70% VEGETATIVE COVER OR OTHER PERMANENT NON-VEGETATIVE COVER
WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION.
DEMOLITION NOTES
1.BEFORE BEGINNING ANY DEMOLITION WORK, THE CONTRACTOR SHALL INSTALL E&S BMPS.
2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, TRANSPORTATION, AND PROPER DISPOSAL OF ALL DEMOLISHED MATERIALS. DEMOLISHED MATERIALS MUST BE MOVED OFFSITE TO AN APPROVED FACILITY.
3.THE CONTRACTOR SHALL PERFORM DEMOLITION WORK AS NECESSARY TO FACILITATE THE PROPOSED WORK, INCLUDING ANY DEMOLITION WORK NOT SPECIFICALLY INDICATED ON THE PLANS.
GENERAL CONSTRUCTION NOTES
1.THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, LABOR AND MATERIALS, INCLUDING FLAGGERS, FOR THE
MAINTENANCE AND PROTECTION OF TRAFFIC (MPT) DURING THE PROJECT IN ACCORDANCE WITH THE PROJECT
PLANS AND PENNDOT PUBLICATION 213 “TEMPORARY TRAFFIC CONTROL GUIDELINES”.
2.EACH CONTRACTOR AND SUBCONTRACTOR PERFORMING EXCAVATION OR DEMOLITION WORK FOR THIS PROJECT IS REQUIRED TO SUBMIT A CONSTRUCTION NOTIFICATION THROUGH THE PA ONE CALL SYSTEM NOT LESS THAN THREE (3) NOR MORE THAN TEN (10) BUSINESS DAYS IN ADVANCE OF BEGINNING EXCAVATION OR DEMOLITION WORK. EACH CONTRACTOR AND SUBCONTRACTOR ARE REQUIRED TO COMPLY WITH ALL PROVISIONS OF THE
UNDERGROUND UTILITY LINE PROTECTION LAW (PA ACT 287 OF 1974, AS AMMENDED).
3.THE CONTRACTOR SHALL ANTICIPATE ENCOUNTERING GROUND WATER INFILTRATION INTO EXCAVATED AREAS DURING CONSTRUCTION. ALL COSTS ASSOCIATED WITH SIZING AND PROVIDING TEMPORARY BYPASS PUMPING
AND/OR DEWATERING SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
4.ALL FILL SHALL BE PLACED IN EIGHT INCH (8”) LAYERS AND THOROUGHLY COMPACTED TO THE SATISFACTION OF THE ENGINEER. IF BORROW FILL IS REQUIRED, IT SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER.
5.THE CONTRACTOR SHALL EXERCISE PARTICULAR CARE WHEN CONSTRUCTING OR RESURFACING PAVEMENT, ESPECIALLY AT INTERSECTIONS AND GUTTER LINES, TO PROVIDE POSITIVE FLOWING STORMWATER. ANY AREAS WHERE WATER IS IMPOUNDED SHALL BE CORRECTED BY THE CONTRACTOR AT NO COST TO THE OWNER.
6.ALL PEDESTRIAN ACCESS TO SIDEWALKS AND STREETS, INCLUDING CROSSWALKS, CURB RAMPS, STREET FURNISHINGS, PEDESTRIAN SIGNALS, PARKING AND OTHER COMPONENTS OF PEDESTRIAN ACCESS PROPOSED IN BUILDINGS, SITES OR THE RIGHT-OF-WAY ARE TO BE IN ACCORDANCE WITH AMERICANS WITH DISABILITIES ACT (ADA) & ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY GUIDELINES AND THE CURRENT PUBLIC RIGHTS-OF-WAY GUIDELINES PROPOSED BY THE ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE
BOARD (ACCESS BOARD).
7.ALL CONSTRUCTION SPECIFICATIONS AND DETAILS NOT SHOWN SHALL BE IN ACCORDANCE WITH PENNDOT
STANDARDS AS DETAILED IN THE LATEST REVISIONS OF THE FOLLOWING:
a.PUBLICATION 35 (BULLETIN 15) “QUALIFIED PRODUCTS LIST FOR CONSTRUCTION”;
b.PUBLICATION 408/2020 ”SPECIFICATIONS”;
c.PUBLICATION 72M/2010 “STANDARDS FOR ROADWAY CONSTRUCTION”;
d.PUBLICATION 111 “TRAFFIC CONTROL - PAVEMENT MARKINGS AND SIGNING STANDARDS”;
e.PUBLICATION 213 “TEMPORARY TRAFFIC CONTROL GUIDELINES”.
INCLUDING ALL APPLICABLE BASELINE DOCUMENT CHANGES AND APPENDICES. THESE CONSTRUCTION
SPECIFICATIONS AND DETAILS MAY BE PURCHASED THROUGH THE PENNDOT SALES STORE AT:
P.O BOX 2028
HARRISBURG, PA 17105-2028
(TELEPHONE: 1-717-787-6746)
UTILITY NOTES
1.LOCATION OF EXISTING UTILITIES ARE APPROXIMATE AND MUST BE VERIFIED IN THE FIELD PRIOR TO THE START
OF CONSTRUCTION.
2.UNLESS NOTED OTHERWISE, THE APPROXIMATE DEPTH OF ALL EXISTING WATER MAIN IS ± 4 FEET.
3.UNLESS NOTED OTHERWISE, APPROXIMATE DEPTH OF ALL EXISTING GAS MAIN IS ± 3 FEET.
4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PRESERVATION OF THE UNDERGROUND AND SURFACE UTILITIES AND STRUCTURES AT OR ADJACENT TO THE SITE OF CONSTRUCTION AND IT SHALL BE AT THEIR
OWN EXPENSE TO REPAIR OR REPLACE ANYTHING THAT THEY DAMAGE.
5.EXISTING SANITARY SEWER MAINS & LATERALS SHOWN MAY NOT BE ACCURATE DUE TO INCOMPLETE UTILITY INFORMATION. CONTRACTOR IS RESPONSIBLE FOR LOCATING, CLEANING, JETTING, AND VACUUMING ALL EXISTING SANITARY SEWER LINES, INLET AND MANHOLE STRUCTURES. EXISTING CLEANOUTS AND SERVICE LATERALS SHALL BE REPLACED AS DIRECTED BY THE ENGINEER. CONTRACTOR SHALL PREPARE SUBMITTAL UPON PROPER FIELD LOCATION AND INVERT VERIFICATION SHOWING REVISED SEWER LAYOUT IF APPLICABLE.
6.THE LIMIT OF DISTURBANCE FOR ANY UTILITY TRENCH WITHIN AN EXISTING ASPHALT ROADWAY SHALL BE LIMITED
TO THE OUTSIDE DIAMETER OF THE UTILITY PLUS TWO FEET (O.D. + 2').
7.THE LAY DOWN AREA FOR THE EXCAVATED MATERIAL SHALL BE IMMEDIATELY ADJACENT TO THE UTILITY TRENCH
AND SHALL BE ISOLATED TO THE EXISTING ASPHALT ROADWAY SURFACE.
8.THE CONTRACTOR SHALL USE PENNDOT NO. 2A COARSE AGGREGATE FOR BACKFILL BENEATH ANY STRUCTURES
OR PAVEMENT AREAS, INCLUDING GRAVEL SURFACES.
9.THE CONTRACTOR MAY USE EXCAVATED MATERIALS FOR BACKFILL IN UNPAVED AREAS, UNLESS OTHERWISE
DIRECTED BY THE ENGINEER.
10.FOR ALL NEW WATER MAINS, THE MINIMUM PIPE COVER SHALL BE THREE AND A HALF FEET (3.5').
11.FOR ALL WATER MAIN CROSSINGS OF SANITARY MAINS, THE MINIMUM VERTICAL CLEARANCE SHALL BE ONE
AND A HALF FEET (1.5').
12.FOR ALL UTILITY CROSSINGS, THE MINIMUM UNSUPPORTED VERTICAL CLEARANCE SHALL BE ONE AND A HALF FEET (1.5'). UTILITY CROSSINGS WITH MINIMUM VERTICAL CLEARANCES LESS THAN 1.5' REQUIRE ADEQUATE
SUPPORT AND APPROVAL OF THE ENGINEER.
13.ALL UTILITY CROSSINGS/OFFSETS SHALL INCLUDE COMPACTED STABILIZATION MATERIAL FOR FULL LENGTH OF
CROSSING.
CONCRETE NOTES
1.UNLESS OTHERWISE NOTED, ALL CONCRETE SIDEWALK SHALL BE FIVE FEET (5') WIDE.
2.UNLESS OTHERWISE NOTED, ALL CONCRETE CURB RADII SHALL BE FIVE FEET (5').
3.EXPANSION JOINTS (A.K.A. ISOLATION JOINTS) SHALL BE INSTALLED IN CONCRETE CURB AND SIDEWALK AREAS EVERY FORTY FEET (40') OR WHEREVER CONCRETE CURB OR SIDEWALK AREAS ADJOIN STRUCTURES (E.G. CURBS, BUILDINGS, UTILITY POLES, EXISTING SIDEWALKS, ETC.).
4.SEPARATE PAYMENT WILL NOT BE MADE FOR PROVIDING EXPANSION JOINT MATERIAL FOR ALL CONCRETE WORK, BUT THE COST SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
5.CONTRACTION JOINTS (A.K.A. CONTROL JOINTS) SHALL BE INSTALLED IN ALL CONCRETE CURB EVERY TEN FEET (10') AND IN SIDEWALK AREAS EVERY EIGHT FEET (8') OR THE WIDTH OF THE SIDEWALK, WHICHEVER IS LESS, EACH WAY. CONTRACTION JOINTS SHALL BE SAWCUT OR HAND GROOVED INTO CONCRETE WITHIN 12 HOURS OF THE
CONCRETE HARDENING.
6.REINFORCEMENT SHALL BE SECURED IN THE PROPER LOCATION IN THE FORMS WITH TIE WIRE OR OTHER BAR SUPPORT SYSTEM TO PREVENT DISPLACEMENT DURING CONCRETE PLACEMENT. STEEL REINFORCEMENT IN CONCRETE SHALL HAVE A MINIMUM COVER OF THREE INCHES (3”) WHEN CAST AGAINST THE EARTH AND TWO
INCHES (2”) WHEN CAST IN REMOVABLE FORMS AND EXPOSED TO THE EARTH OR WEATHER.
7.NO ADDITIONAL WATER SHALL BE ADDED TO CONCRETE.
8.ON FORMED CONCRETE SURFACES, THE CONTRACTOR SHALL CURE FINISHED CONCRETE BY APPLYING TWO (2) COATS OF A WHITE PIGMENTED CURING COMPOUND (ASTM C 309, TYPE 2). THE FIRST COAT SHALL BE APPLIED IMMEDIATLY AFTER STRIPPING THE FORMS. THE SECOND COAT SHALL BE APPLIED IMMEDIATELY AFTER THE FIRST
COAT HAS SET.
9.COLD WEATHER CONCRETE. IN ACCORDANCE WITH ACI 306R-16, THE CONTRACTOR SHALL PROVIDE ADDITIONAL
PROTECTION WHEN PLACING CONCRETE DURING COLD WEATHER, DEFINED AS 40°F OR BELOW:
a.THE CONTRACTOR SHALL ARANGE FOR COLD WEATHER CONCRETE EQUIPMENT AND MATERIALS SUCH AS TARPING OR BLANKETS TO BE AT THE PROJECT SITE BEFORE COLD WEATHER IS LIKELY TO OCCUR.
b.FROZEN SUBGRADE MUST BE THAWED PRIOR TO THE PLACEMENT OF CONCRETE.
c.CURE AND PROTECT CONCRETE AGAINST DAMAGE FROM FREEZING FOR A MINIMUM PERIOD OF THREE (3) DAYS, UNLESS OTHERWISE SPECIFIED. THE PROTECTION PERIOD MAY BE REDUCED TO TWO (2) DAYS IF ONE OR MORE OF THE FOLLOWING ARE IMPLEMENTED: (1) TYPE 3 PORTLAND CEMENT MEETING REQUIREMENTS OF ASTM C 150; (2) A STRENGTH ACCELERATING ADMIXTURE MEETING THE REQUIREMENTS OF ASTM C 494;
OR (3) 100 LB/CY OF ADDITIONAL CEMENT.
PAVEMENT NOTES
1.AT THE END OF EACH WORKDAY, THE CONTRACTOR SHALL BACKFILL ANY EXCAVATED AREAS WITHIN ROADWAYS, INSTALL TEMPORARY PAVEMENT RESTORATIONS AND REOPEN ROADWAYS FOR VEHICLE TRAFFIC. THE USE OF COLD PATCH MATERIAL OR STEEL PLATES ON LOCAL STREETS REQUIRES PRIOR AUTHORIZATION BY THE ENGINEER
AND IS PROHIBITED ON STATE HIGHWAYS.
2.THE CONTRACTOR SHALL INVENTORY ALL EXISTING PAVEMENT STRIPING AND MARKINGS PRIOR TO MILLING.
3.THE CONTRACTOR SHALL REMOVE ANY TEMPORARY PAVEMENT RESTORATIONS AND INSTALL PERMANENT PAVEMENT RESTORATIONS FOR ALL EXCAVATED AREAS PRIOR TO BEGINNING SAWCUTTING OR MILLING FOR
PAVEMENT RESURFACING WORK.
4.THE CONTRACTOR SHALL VERIFY THE LIMITS OF PAVEMENT RESURFACING OR RECONSTRUCTION WORK WITH THE
ENGINEER PRIOR BEGINNING TO ASSOCIATED SAWCUTTING OR MILLING.
5.THE CONTRACTOR SHALL SAWCUT CLEAN JOINTS THROUGH EXISTING ASPHALT PAVEMENT TO FACILIATE NEW BUTT JOINTS. THE CONTRACTOR SHALL MILL AN EIGHTEEN INCHES (18”) WIDTH OF THE EXISTING PAVEMENT BEYOND THE JOINT TO PROVIDE AN OVERLAP OF NEW SURFACE COURSE ASPHALT PAVEMENT OVER EXISTING
ASPHALT PAVEMENT.
6.AFTER MILLING ASPHALT PAVEMENT SURFACES, THE CONTRACTOR SHALL PROVIDE A FULLY LOADED TRI-AXLE DUMP TRUCK AND PERFORM A PROOF ROLL OF MILLED SURFACES WITH THE ENGINEER TO DETERMINE AREAS FOR BASE REPAIR. BASE REPAIRS SHALL BE PERFORMED PRIOR TO INSTALLING SCRATCH, LEVELING OR WEARING
COURSES.
7.THE CONTRACTOR SHALL ADJUST ALL EXISTING MANHOLES, UTILITY COVERS AND VALVE BOXES TO AN ELEVATION
FIVE-EIGHTHS OF AN INCH (5/8”) BELOW THE PROPOSED PAVEMENT SURFACE.
8.THE CONTRACTOR SHALL PAINT EXISTING VERTICAL SURFACES OF CURBS, STRUCTURES, GUTTERS, AND PAVEMENTS THAT WILL BE IN CONTACT WITH ASPHALT MIXTURES WITH A UNIFORM COATING OF EITHER EMULSIFIED ASPHALT, CONSISTING OF PENNDOT MATERIAL CLASS TACK OR HOT ASPHALT BINDER OF THE CLASS
AND TYPE AS SPECIFIED IN SECTION 460 OF PENNDOT PUBLICATION 408.
CONTRACT NOTES
1.THE CONTRACTOR SHALL MAKE A PRE-CONSTRUCTION VIDEO OF THE PROJECT AREA BEFORE BEGINNING ANY
CONSTRUCTION ACTIVITIES.
2.THE CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT ALL EXISTING CONCRETE CURB AND SIDEWALK AREAS NOT SHOWN TO BE REMOVED OR REPLACED. THE CONTRACTOR WILL BE RESPONSIBLE FOR COMPLETE REMOVAL AND REPLACEMENT OF ANY DAMAGED CURB OR SIDEWALK NOT DOCUMENTED PRIOR TO THE START OF CONSTRUCTION
AT NO ADDITIONAL COST TO THE OWNER.
3.THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH OTHER PRIME CONTRACTORS FOR THIS PROJECT, IF APPLICABLE. IN ADDITION, THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH PRIME CONTRACTORS ON OTHER PROJECTS UNDER CONSTRUCTION NEAR THE PROJECT AREA. ANY COORDINATION ISSUES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. THERE WILL NOT BE ANY SEPARATE PAYMENT FOR THIS COORDINATION, BUT THE COST SHOULD BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
4.RECONSTRUCTION OF EXISTING MANHOLES AND INLETS, INCLUDING CONCRETE CAPS AND OTHER NECESSARY MODIFICATIONS TO ACCOMMODATE NEW INLET CONSTRUCTION, SHALL BE INCLUDED IN THE UNIT PRICE BID FOR
INLETS AND MANHOLES OF THE VARIOUS KINDS.
5.SEPARATE PAYMENT WILL NOT BE MADE FOR SAWCUTTING OF ANY KIND, BUT THE COST SHALL BE INCLUDED IN
THE VARIOUS ITEMS OF THE PROPOSAL.
6.SEPARATE PAYMENT WILL NOT BE MADE FOR STEEL TREE ROOT PROTECTION PLATES, BUT THE COST SHALL BE
INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
7.SEPARATE PAYMENT WILL NOT BE MADE FOR THE REMOVAL, TEMPORARY STORAGE AND REINSTALLATION OF EXISTING SIGNAGE ALONG THE PROJECT AREA, BUT THE COST SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE
PROPOSAL.
8.SEPARATE PAYMENT WILL NOT BE MADE FOR THE EXCAVATION OF ROCK.
9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR TRANSPORTATION AND PROPER DISPOSAL OF ALL UNUSED MATERIAL EXCAVATED FROM THE PROJECT SITE. PROPER DISPOSAL SHALL BE IN ACCORDANCE WITH PA DEP
REQUIREMENTS.
10.CONTRACTOR SHALL RESTORE ALL EXISTING FEATURES DISTURBED DURING CONSTRUCTION (I.E. MAILBOXES, IRRIGATION SYSTEMS, LANDSCAPING, ETC.). ALL COSTS SHALL BE INCLUDED IN THE PRICE BID FOR SITE CLEARING.
11.THE CONTRACTOR SHALL ANTICIPATE GROUND WATER INFILTRATION INTO ALL OF THE COMBINED SEWER/STORM SEWER PIPES, INLETS AND MANHOLES WHEN PERFORMING THE VARIOUS TASKS ASSOCIATED WITH THIS PROJECT.
ALL COSTS ASSOCIATED WITH THE TEMPORARY BYPASS PUMPING AND OR DEWATERING SHALL BE INCLUDED IN
THE VARIOUS ITEMS IN THE PROPOSAL.
12.SEPARATE PAYMENT WILL NOT BE MADE FOR EXCAVATION, DEWATERING, FITTINGS, PIPE BEDDING, SHEETING, BRACING, SHORING, INLET CONNECTIONS, TRAPS, AND SUITABLE BACKFILL MATERIAL INVOLVED IN ALL PIPE AND ASSOCIATED STRUCTURES REMOVAL, RECONSTRUCTION AND INSTALLATION, BUT THE COST SHALL BE INCLUDED IN
THE VARIOUS ITEMS OF THE PROPOSAL REGARDLESS OF DEPTH.
SITE SAFETY, CLEANLINESS & RESTORATION NOTES
1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY ON THE PROJECT SITE AND FOR FOLLOWING ALL OSHA AND
LOCAL SAFETY STANDARDS.
2.THE CONTRACTOR SHALL ENSURE THAT THE SITE IS SECURE AT THE END OF EACH WORKDAY. ALL EQUIPMENT AND MATERIALS SHOULD BE STORED NEATLY AND SECURELY. EXCAVATED AREAS SHALL BE BACKFILLED OR SECURED TO
PREVENT ANY FALL HAZARD.
3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING PAVED SURFACES, INCLUDING SIDEWALKS, FREE AND CLEAR OF SEDIMENT AND IN A BROOM SWEPT CONDITION WHEN OPEN TO PUBLIC USE. AT A MINIMUM, THE CONTRACTOR SHALL CLEAN PAVED SURFACES AT THE END OF EACH WORKDAY AND WHEN DIRECTED BY THE
ENGINEER.
4.THE ALL VEGETATED AREAS DISTRIBUTED DURING CONSTRUCTION SHALL BE TOPSOILED, SEEDED, FERTILIZED AND COVERED WITH STRAW MULCH. THE CONTRACTOR SHALL BE RESPONSIBLE FOR WATERING AND/OR RE-SEEDING
AS NECESSARY TO ENSURE VEGETATIVE STABILIZATION.
5.ALL PAVED AND CONCRETE AREAS EXCAVATED OR DAMAGED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITION AT LEAST EQUAL TO THAT WHICH EXISTED PRIOR TO THE START OF CONSTRUCTION.
6.PRIOR TO FINAL PAYMENT, THE CONTRACTOR SHALL PERFORM FINAL CLEANING. FINAL CLEANING SHALL INCLUDE REMOVAL AND PROPER DISPOSAL OF ALL EXCESS CONSTRUCTION MATERIALS AND DEBRIS AS WELL AS CLEANING
ALL PAVED SURFACES.
G
EN
ER
AL
N O
TE
S
C001 SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
BWT BWT KSW
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
\\E gn yt eD riv e\
R
VE
_E gn yt e\
Sh ar ed \2
_O ld
Se rv er s\
Pi tts bu rg h\ Sh ar ed
\K en ne dy
T w p\
PA
KT
T0
AC
O
3\ C
AD
\S
EW
ER
R
EP
AI
R
P
LA
N
PA
KT
T0
).d w g
/2 2/
1:
:1
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
(412) 263-2200, FAX (412) 263-2210
105 BRAUNLICH DRIVE, SUITE 100
PITTSBURGH, PA 15237
REMINGTON
& VERNICK
ENGINEERS
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
PROFESSIONAL ENGINEER LIC. No. PE-040662-E
MICHAEL G. MEYER
DATE:
09/22/2025
PAKTT096
AS NOTED
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
AL
LE
G H
EN
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
ST
AR
LI
N
G D
R
IV
E
SA
N
IT
AR
Y
SE
W
ER
R
EH
AB
IL
IT
AT
IO
N P
R O
JE
C
T
CONSTRUCTION
DOCUMENTS
N
PA ONE - CALL SYSTEM
R
-8
-2
-1
N
AC
L
YLS N
P
N
OT
V A
EB FO
AI
O
U
YE
O
CE LA L
D
STE
S
IG
Y
M I
C N
9/22/2025
PH28-B
PH28-C
PH28-D
POINT REPAIR,BVV
PH26-J
PH26-L
ASSUMED
LOCATION
PH26-K
ASSUMED LOCATION
PH26-M/CLEANOUT
POINT REPAIR,CP
ASSUMED
UPSTREAM, MCCOY
RD
MH-TO-MH CIPP
MH-TO-M
H CIPP
M H-
TO
-M
H
CI
PP
PH31 PH33
PH34
PH35
PH36
PH37
ST
ARL
IN
G D
R
MH-TO-M
H CIPP
180 lf - 8"
MH-TO-MH CIPP
PH31-PH32,PH32-PH33
180 lf - 8"
N. VIREO DR ST
AR
LI
NG
D R
MALLARD DR
TEAL DR
STARLING DR
S VIREO DR
S VIREO
DRTANAGER DR
M
CC
OY
RD
MCCOY RD
N VIREO DR
N
VIREO
DR
ASSUMED LOCATION
PH26-E/CLEANOUT
POINT REPAIR, LAT.
DEFECT: (1X) AT 10LF
SPOT LINER
MH-TO-MH CIPP
PH37-A-END
PH37-1-END
PH28
PH25
PH27
PH28-A
PH28-B
PH28-C
PH28-D
ASSUMED
LOCATION
PH24-A
PH26-C
PH26-D
PH26-B
ASSUMED
LOCATION
PH26-A
PH26-H
PH26-I
PH26-J
PH26-L
PH26-A1
ASSUMED
LOCATION
PH25.1
(Infiltration)
PH26
PH26.1
ASSUMED
LOCATION
PH24-B ASSUMED
LOCATION
PH24
ASSUMED
LOCATION
PH23 ASSUMED
LOCATION
PH22
ASSUMED
LOCATION
PH21
ASSUMED
LOCATION
PH20
PH18-E
PH18-D
ASSUMED
LOCATION
PH18-A1
ASSUMED
LOCATION
PH19
ASSUMED
LOCATION
PH18-A
ASSUMED
LOCATION
PH26-K
ASSUMED
LOCATION
PH18
ASSUMED
LOCATION
PH17
ASSUMED
LOCATION
PH16
ASSUMED
LOCATION
PH15
ASSUMED
LOCATION
PH14
ASSUMED
LOCATION
PH13
ASSUMED
LOCATION
PH12
ASSUMED
LOCATION
PH11 ASSUMED
LOCATION
PH10
ASSUMED
LOCATION
PH10-A
ASSUMED
LOCATION
PH10-B
ASSUMED
LOCATION
PH10-C
ASSUMED
LOCATION
CLEANOUT
ASSUMED LOCATION
PH26-M/CLEANOUT
PH26.2
ASSUMED
LOCATION
PH26.3
ASSUMED
LOCATION
PH18-D1
ASSUMED
LOCATION
PH18-D3
ASSUMED
LOCATION
PH13-A1
ASSUMED
LOCATION
PH13-A
ASSUMED
LOCATION
PH13-B
ASSUMED
LOCATION
PH13-C
ASSUMED
LOCATION
PH13-D1
ASSUMED
LOCATION
PH13-D
ASSUMED
LOCATION
PH13-E
ASSUMED
LOCATION
PH13-E1
ASSUMED
LOCATION
PH13-E2
ASSUMED
LOCATION
PH13-E3
ASSUMED
LOCATION
PH13-F
ASSUMED
LOCATION
PH13-G1
ASSUMED
LOCATION
PH13-G
ASSUMED
LOCATION
PH13-HASSUMED
LOCATION
PH13-D5
ASSUMED
LOCATION
PH13-D3
ASSUMED
LOCATION
PH13-D4
ASSUMED
LOCATION
PH13-D2
ASSUMED
LOCATION
PH18-C
ASSUMED
LOCATION
PH18-B
ASSUMED
LOCATION
PH18-F
ASSUMED
LOCATION
PH18-G
(Infiltration)
ASSUMED
LOCATION
PH18-H
UPSTREAM, MCCOY
RD
PH29
PH30
PH31
PH32
PH33
PH34
PH35
PH36
PH37
ASSUMED
LOCATION
PH18-D5
ASSUMED
LOCATION
PH18-D4
ASSUMED LOCATION
PH26-E/CLEANOUT
PH37-A-END
PH37-1-END
R
EH
AB
IL
IT
AT
IO
N
P
LA
N
0 50' 100'
1 INCH =
GRAPHIC SCALE
50 FT.
150'
- AD: ATTACHED DEPOSITS
- BVV: BROKEN VOID VISIBLE
- CP: CRACKED/FRACTURED PIPE
- CL: CAPPED LATERAL CONNECTION
- LL: LIVE LATERAL CONNECTION
- PL: PROTRUDING LATERAL
- PRP: POINT REPAIR PATCH
- PMC: PIPE MATERIAL CHANGE
- PDC: PIPE DIAMETER CHANGE
- JI: JOINT INFILTRATION
- JS: JOINT SEPARATION
- JO: JOINT OFFSET
- RI: ROOT INTRUSION
- LINETYPE - SEWER NOT CCTV INSPECTED-ASSUMED LOCATION
- LINETYPE - SEWER CCTV INSPECTED
PLAN LEGEND
REFER TO C400-C401 FOR FURTHER DETAIL REGARDING
SANITARY SEWER MANHOLE AND MAINLINE PIPE DEFECTS
AND RECOMMENDED REPAIRS. C300
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
BWT BWT KSW
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
\\E gn yt eD riv e\
R
VE
_E gn yt e\
Sh ar ed \2
_O ld
Se rv er s\
Pi tts bu rg h\ Sh ar ed
\K en ne dy
T w p\
PA
KT
T0
AC
O
3\ C
AD
\S
EW
ER
R
EP
AI
R
P
LA
N
PA
KT
T0
).d w g
/2 2/
1:
:1
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
(412) 263-2200, FAX (412) 263-2210
105 BRAUNLICH DRIVE, SUITE 100
PITTSBURGH, PA 15237
REMINGTON
& VERNICK
ENGINEERS
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
PROFESSIONAL ENGINEER LIC. No. PE-040662-E
MICHAEL G. MEYER
DATE:
09/22/2025
PAKTT096
AS NOTED
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
AL
LE
G H
EN
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
ST
AR
LI
N
G D
R
IV
E
SA
N
IT
AR
Y
SE
W
ER
R
EH
AB
IL
IT
AT
IO
N P
R O
JE
C
T
CONSTRUCTION
DOCUMENTS
N
PA ONE - CALL SYSTEM
R
-8
-2
-1
N
AC
L
YLS N
P
N
OT
V A
EB FO
AI
O
U
YE
O
CE LA L
D
STE
S
IG
Y
M I
C N
9/22/2025
CCTV LEGEND
MAIN SEWER CLEANING AND TELEVISING
N.T.S.
M H-
TO
-M
H
CI
PP
POINT REPAIR
(BVV)
PH28
PH25
PH27
PH28-A
PH28-B
PH28-C
POINT REPAIR,BVV
PH26-A1
PH26
PH26.1
ASSUMED
LOCATION
PH26.3
MH-TO-M
H CIPP
M H-
TO
-M
H
CI
PP
SPOT LINER
POINT REPAIR (CP)
MH-TO-MH CIPP240 lf-10"
N.
V
IR
EO
D R
PH29
PH30
PH31
PH32
PH33
PH34
PH35
M H-
TO
-M
H
CI
PP
lf-
8"
POINT
REPAIR
(CP)
ST
ARL
IN
G D
R
MH-TO-MH CIPP
PH31-PH32,PH32-PH33
180 lf - 8"
PINE HOLLOW RD
FA
IR
HA
VE
N
RD
N. VIREO DR ST
AR
LI
NG
D R
MALLARD DR
PREV. SPOT LINER
W/INFILTRATION,
POINT REPAIR
M
CC
O Y
RD
M
CC
OY
RD
HECKEL RD
ASSUMED LOCATION
PH26-E/CLEANOUT
REHAB MH 25.1 PHASE 1 REHAB PROJECT
PH28
PH25
PH27
PH28-A
PH28-B
PH28-C
PH28-D
ASSUMED
LOCATION
PH24-A
PH26-C
PH26-D
PH26-B
ASSUMED
LOCATION
PH26-A
PH26-H
PH26-I
PH26-J
PH26-L
PH26-A1
ASSUMED
LOCATION
PH25.1
(Infiltration)
PH26
PH26.1
ASSUMED
LOCATION
PH24-B ASSUMED
LOCATION
PH24
ASSUMED
LOCATION
PH23 ASSUMED
LOCATION
PH22
ASSUMED
LOCATION
PH21
ASSUMED
LOCATION
PH20
PH18-E
PH18-D
ASSUMED
LOCATION
PH18-A1
ASSUMED
LOCATION
PH19
ASSUMED
LOCATION
PH18-A
ASSUMED
LOCATION
PH26-K
ASSUMED
LOCATION
PH18
ASSUMED
LOCATION
PH17
ASSUMED
LOCATION
PH16
ASSUMED
LOCATION
PH15
ASSUMED
LOCATION
PH14
ASSUMED
LOCATION
PH13
ASSUMED
LOCATION
PH12
ASSUMED
LOCATION
PH11 ASSUMED
LOCATION
PH10
ASSUMED
LOCATION
PH10-A
ASSUMED
LOCATION
PH10-B
ASSUMED
LOCATION
PH10-C
ASSUMED
LOCATION
CLEANOUT
ASSUMED LOCATION
PH26-M/CLEANOUT
PH26.2
ASSUMED
LOCATION
PH26.3
ASSUMED
LOCATION
PH18-D1
ASSUMED
LOCATION
PH18-D3
ASSUMED
LOCATION
PH13-A1
ASSUMED
LOCATION
PH13-A
ASSUMED
LOCATION
PH13-B
ASSUMED
LOCATION
PH13-C
ASSUMED
LOCATION
PH13-D1
ASSUMED
LOCATION
PH13-D
ASSUMED
LOCATION
PH13-E
ASSUMED
LOCATION
PH13-E1
ASSUMED
LOCATION
PH13-E2
ASSUMED
LOCATION
PH13-E3
ASSUMED
LOCATION
PH13-F
ASSUMED
LOCATION
PH13-G1
ASSUMED
LOCATION
PH13-G
ASSUMED
LOCATION
PH13-HASSUMED
LOCATION
PH13-D5
ASSUMED
LOCATION
PH13-D3
ASSUMED
LOCATION
PH13-D4
ASSUMED
LOCATION
PH13-D2
ASSUMED
LOCATION
PH18-C
ASSUMED
LOCATION
PH18-B
ASSUMED
LOCATION
PH18-F
ASSUMED
LOCATION
PH18-G
(Infiltration)
ASSUMED
LOCATION
PH18-H
UPSTREAM, MCCOY
RD
PH29
PH30
PH31
PH32
PH33
PH34
PH35
PH36
PH37
ASSUMED
LOCATION
PH18-D5
ASSUMED
LOCATION
PH18-D4
ASSUMED LOCATION
PH26-E/CLEANOUT
PH37-A-END
PH37-1-END
R
EH
AB
IL
IT
AT
IO
N
P
LA
N
0 50' 100'
1 INCH =
GRAPHIC SCALE
50 FT.
150'
PLAN LEGEND
REFER TO C400-C401 FOR FURTHER DETAIL REGARDING
SANITARY SEWER MANHOLE AND MAINLINE PIPE DEFECTS
AND RECOMMENDED REPAIRS.
- AD: ATTACHED DEPOSITS
- BVV: BROKEN VOID VISIBLE
- CP: CRACKED/FRACTURED PIPE
- CL: CAPPED LATERAL CONNECTION
- LL: LIVE LATERAL CONNECTION
- PL: PROTRUDING LATERAL
- PRP: POINT REPAIR PATCH
- PMC: PIPE MATERIAL CHANGE
- PDC: PIPE DIAMETER CHANGE
- JI: JOINT INFILTRATION
- JS: JOINT SEPARATION
- JO: JOINT OFFSET
- RI: ROOT INTRUSION
- LINETYPE - SEWER NOT CCTV INSPECTED-ASSUMED LOCATION
- LINETYPE - SEWER CCTV INSPECTED
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
BWT BWT KSW
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
\\E gn yt eD riv e\
R
VE
_E gn yt e\
Sh ar ed \2
_O ld
Se rv er s\
Pi tts bu rg h\ Sh ar ed
\K en ne dy
T w p\
PA
KT
T0
AC
O
3\ C
AD
\S
EW
ER
R
EP
AI
R
P
LA
N
PA
KT
T0
).d w g
/2 2/
1:
:2
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
(412) 263-2200, FAX (412) 263-2210
105 BRAUNLICH DRIVE, SUITE 100
PITTSBURGH, PA 15237
REMINGTON
& VERNICK
ENGINEERS
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
PROFESSIONAL ENGINEER LIC. No. PE-040662-E
MICHAEL G. MEYER
DATE:
09/22/2025
PAKTT096
AS NOTED
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
AL
LE
G H
EN
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
ST
AR
LI
N
G D
R
IV
E
SA
N
IT
AR
Y
SE
W
ER
R
EH
AB
IL
IT
AT
IO
N P
R O
JE
C
T
CONSTRUCTION
DOCUMENTS
N
PA ONE - CALL SYSTEM
R
-8
-2
-1
N
AC
L
YLS N
P
N
OT
V A
EB FO
AI
O
U
YE
O
CE LA L
D
STE
S
IG
Y
M I
C N
9/22/2025
C301
CCTV LEGEND
MAIN SEWER CLEANING AND TELEVISING
N.T.S.
M
AN
H O
LE
D
ET
AI
L
AN
D R
EP
AI
R
PL
AN
T
AB
LE
S
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
BWT BWT KSW
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
\\E gn yt eD riv e\
R
VE
_E gn yt e\
Sh ar ed \2
_O ld
Se rv er s\
Pi tts bu rg h\ Sh ar ed
\K en ne dy
T w p\
PA
KT
T0
AC
O
3\ C
AD
\S
EW
ER
R
EP
AI
R
P
LA
N
PA
KT
T0
).d w g
/2 2/
1:
:2
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
(412) 263-2200, FAX (412) 263-2210
105 BRAUNLICH DRIVE, SUITE 100
PITTSBURGH, PA 15237
REMINGTON
& VERNICK
ENGINEERS
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
PROFESSIONAL ENGINEER LIC. No. PE-040662-E
MICHAEL G. MEYER
DATE:
09/22/2025
PAKTT096
AS NOTED
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
AL
LE
G H
EN
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
ST
AR
LI
N
G D
R
IV
E
SA
N
IT
AR
Y
SE
W
ER
R
EH
AB
IL
IT
AT
IO
N P
R O
JE
C
T
CONSTRUCTION
DOCUMENTS
N
PA ONE - CALL SYSTEM
R
-8
-2
-1
N
AC
L
YLS N
P
N
OT
V A
EB FO
AI
O
U
YE
O
CE LA L
D
STE
S
IG
Y
M I
C N
C400
SA
N
IT
AR
Y
SE
W
ER
P
IP
E D
EF
EC
T
TA
BL
ES
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
BWT BWT KSW
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
\\E gn yt eD riv e\
R
VE
_E gn yt e\
Sh ar ed \2
_O ld
Se rv er s\
Pi tts bu rg h\ Sh ar ed
\K en ne dy
T w p\
PA
KT
T0
AC
O
3\ C
AD
\S
EW
ER
R
EP
AI
R
P
LA
N
PA
KT
T0
).d w g
/2 2/
1:
:2
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
(412) 263-2200, FAX (412) 263-2210
105 BRAUNLICH DRIVE, SUITE 100
PITTSBURGH, PA 15237
REMINGTON
& VERNICK
ENGINEERS
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
PROFESSIONAL ENGINEER LIC. No. PE-040662-E
MICHAEL G. MEYER
DATE:
09/22/2025
PAKTT096
AS NOTED
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
AL
LE
G H
EN
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
ST
AR
LI
N
G D
R
IV
E
SA
N
IT
AR
Y
SE
W
ER
R
EH
AB
IL
IT
AT
IO
N P
R O
JE
C
T
CONSTRUCTION
DOCUMENTS
N
PA ONE - CALL SYSTEM
R
-8
-2
-1
N
AC
L
YLS N
P
N
OT
V A
EB FO
AI
O
U
YE
O
CE LA L
D
STE
S
IG
Y
M I
C N
C401
PIPE TRENCH DETAIL - UNPAVED AREA
STANDARD MANHOLE FRAME AND COVER DETAIL
PIPE TRENCH DETAIL - PAVED AREA
C O
N
ST
R U
C
TI
O N
D
ET
AI
LS
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
BWT BWT KSW
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
\\E gn yt eD riv e\
R
VE
_E gn yt e\
Sh ar ed \2
_O ld
Se rv er s\
Pi tts bu rg h\ Sh ar ed
\K en ne dy
T w p\
PA
KT
T0
AC
O
3\ C
AD
\S
EW
ER
R
EP
AI
R
P
LA
N
PA
KT
T0
).d w g
/2 2/
1:
:3
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
(412) 263-2200, FAX (412) 263-2210
105 BRAUNLICH DRIVE, SUITE 100
PITTSBURGH, PA 15237
REMINGTON
& VERNICK
ENGINEERS
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
PROFESSIONAL ENGINEER LIC. No. PE-040662-E
MICHAEL G. MEYER
DATE:
09/22/2025
PAKTT096
AS NOTED
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
TO
W
N
SH
IP
O
F
KE
N N
ED
Y
AL
LE
G H
EN
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
ST
AR
LI
N
G D
R
IV
E
SA
N
IT
AR
Y
SE
W
ER
R
EH
AB
IL
IT
AT
IO
N P
R O
JE
C
T
CONSTRUCTION
DOCUMENTS
N
PA ONE - CALL SYSTEM
R
-8
-2
-1
N
AC
L
YLS N
P
N
OT
V A
EB FO
AI
O
U
YE
O
CE LA L
D
STE
S
IG
Y
M I
C N
C500
| Sheets and Views |
| SEWER REPAIR PLAN (PAKTT084)-C000 (BID) |
| SEWER REPAIR PLAN (PAKTT084)-C001 (BID) |
| SEWER REPAIR PLAN (PAKTT084)-C300 (BID) |
| SEWER REPAIR PLAN (PAKTT084)-C301 (BID) |
| SEWER REPAIR PLAN (PAKTT084)-C400 (BID) |
| SEWER REPAIR PLAN (PAKTT084)-C401 (BID) |
| SEWER REPAIR PLAN (PAKTT084)-C500 (BID) |
File details come from the government source that posted it. Updated .